• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Desenvolvimento de critérios para seleção de adesivos utilizados na fabricação de pás de turbinas eólicas /

Ricci, Ricardo Pedroso. January 2012 (has links)
Orientador: Sandro D, Mancini / Banca: Sandra Andrea Cruz / Banca: Rogerio Scatena Biscaro / Resumo: O processo de fabricação das pás de turbinas eólicas envolve a colagem de estruturas fabricadas em plásticos reforçados com fibra de vidro. Neste trabalho foram analisadas os três principais tipos de adesivos estruturais utilizados pelos fabricante de pás (epóxi, poliuretano e metil-metacrilato), com o objetivo de desenvolver critérios que auxiliem na seleção de adesivos e de tratamentos superficiais aplicados às estrutuaras a serem coladas. A caracterização dos adesivos envolveu dois tipos de ensaios mecânicos: o cisalhamento de juntas de sobreposição simples e a clivagem de juntas adesivas. Dois tipos de tratamento das superfícies dos aderentes foram utilizados: camada de sacrifício removível (peel-ply) e abrasão. Também foi realizada a análise dos modos de falha das juntas ensaiadas como auxílio de compatibilidade entre adesivo e substrato. Os resultados mostram que o tratamento via peel-ply foi o mais eficiente para as juntas coladas com epóxi e testadas em cisalhamento, ao apresentar um aumento de 28% na resistência em relação às superfícies sem tratamento. Imagens de microscopia eletrônica de varredura sugerem que esse tratamento gerou uma área maior de contato em relação à superfície não tratada e que causou menos danos à superfície do aderente do que o método abrasivo. Os grupos colados com adesivo metil metacrilato, independentemente do tipo de tratamento, obtiveram os maiores valores nos ensaios de clivagem, cerca de 170% superiores aos demais grupos. Para estruturas de pás corretamente projetadas para evitar cargas de peeling em suas juntas adesivas, este trabalho mostra que a melhor opção são aderentes tratados com peel-ply e colados com epóxi. Contudo, um plano de testes deve ser elaborado sempre que houver a necessidade do emprego de um novo adesivo ou método de preparação superficial / Abstract: The manufacturing process of wind turbine blades involves the bonding of structures made of glass reinforced plastic. This work analyzes the theree main types of structural adhesives used by blades manufactures (epoxy, polyurethane and methyl methacrylate), with the goal of developing criteria to assist in the selection of adhesives and surface treatments applied to the structures to be bonded. The characterization of the adhesives involved two types of mechanical tests: single lap shear joints and cleavage of adhesive joints. Two types of surface treatment of the adherents were used: removable sacrifical layer (peel-ply) and abrasion. The joint failure mode analysis was also carried out as an aid to the study of compatibility between adhesive and substrate. The results show that treatment via peel-ply was the most efficient for epoxy bonded substrates tested in shear, by presenting a 28% increase in strengh compared to untreated surfaces. Images of scanning electron microscopy suggest that this treatment led to a larger area of contact relative to untreated surfaces and caused less damage to the substrate's surface than the abrasive method. The groups bonded with methyl methacrylate regardless the type of treatment, had the highest values in the cleavage test, approximately 170% higher than other groups. For propertly designed blades, that avoid peeling loads in their adhesive joints, this work shows that the best option are substrate treated with peel-ply and bonded with epoxy. However, a test plan should be prepared whenever there is the necessity of using a new adhesive or method of surface preparation / Mestre
202

Infiltração apical em obturações de canais realizadas com dois tipos de cimento após aplicação do laser ND:YAG ou solução de EDTA nas paredes do canal radicular

Bassili, Leandro de Oliveira 20 September 2002 (has links)
Avaliou-se a influência da aplicação do laser Nd:YAG ou solução de EDTA nas paredes de canais radiculares, sobre a capacidade seladora de obturações realizadas com dois tipos de cimento. Utilizou-se sessenta e oito dentes pré-molares inferiores humanos, dos quais sessenta e dois foram usados para analisar o selamento apical e seis para analisar as características das paredes dos canais radiculares sob M.E.V, após o tratamento pelo EDTA trissódico e pelo laser Nd:YAG. Os dentes tiveram suas coroas cortadas na junção cemento - esmalte e os canais radiculares foram instrumentados pela técnica automatizada com padronização dos forames apicais por uma lima tipo Kerr nº 25. Terminada a instrumentação dos canais, as superfícies externas radiculares foram impermeabilizadas, exceto o forame apical. As raízes foram, então, divididas em 4 grupos de 15, de acordo com o tipo de tratamento realizado nas paredes dos canais radiculares e o tipo de cimento utilizado para a mesma. Grupo I - aplicação do laser Nd:YAG e obturação com cimento AH Plus; Grupo II - aplicação do laser Nd:YAG e obturação com cimento Endofill; Grupo III - aplicação de EDTA por 5 minutos e obturação com cimento AH Plus; Grupo IV - aplicação de EDTA por 5 minutos e obturação com cimento Endofill. Dois dentes serviram de controles negativo e positivo. Em seguida, as raízes foram imersas em solução de azul de metileno a 2%, durante 48 horas. Após a remoção da impermeabilização foi realizado o desgaste das raízes para leitura da magnitude das infiltrações, por meio de um microscópio óptico pela técnica da planimetria. Os resultados indicaram que o cimento AH Plus foi o que permitiu menor infiltração apical, assim como a aplicação do laser Nd:YAG, quando utilizado no tratamento das paredes dos canais radiculares, anteriormente à obturação. / This study aimed at evaluating the influence of applying Nd:YAG laser or an EDTA solution in the root canal walls, on the sealing capacity of fillings performed with two sorts of cements. Sixty-eight human lower premolars, being 62 used for the analysis of apical sealing and 6 to analyse the wall characteristics of root canals under SEM, following treatment with trisodic EDTA and Nd:YAG laser were utilized. The teeth had their crowns cut at the cementoenamel junction and the root canals were instrumented through automatized technique with standardization of apical foramen by a # 25 Kerr file. Upon completion of root canal instrumentation, the external root surfaces were impermeabilized, except for the foramen. The roots were then divided into 4 groups of 15, according to the type of treatment performed on the root canal walls and the type of cement utilized in the filling. Group I – application of Nd:YAG laser and filling with AH Plus cement; Group II – application of Nd:YAG laser and filling with Endofill cement; Group III – application of EDTA for 5 minutes and filling with AH Plus cement; Group IV - application of EDTA for 5 minutes and filling with Endofill cement. Two teeth served as negative and positive controls. Afterwards, the roots were immersed in a 2%-methylene blue dye, for 48 hours. Wearing of the roots took place following the removal of impermeabilization for the reading of leakage magnitude, by means of a light microscope through planimetry technique. The results indicated AH Plus cement as the one to allow the least apical leakage, as well as Nd:YAG laser application, when utilized in the treatment of root canal walls, prior to filling.
203

Efeito da associação de um cimento de ionômero de vidro modificado por resina com sistemas adesivos convencionais de frasco único. Análise da liberação de flúor, inibição de desmineralização e avaliação clínica

Wang, Linda 12 December 2003 (has links)
Foram testadas as hipóteses nulas de que sistemas adesivos de frasco único não influenciariam as propriedades de liberação de flúor, inibição da desmineralização e longevidade clínica de um cimento de ionômero de vidro modificado por resina. Em uma primeira etapa, um estudo in vitro foi desenvolvido para verificar a influência do adesivo na liberação de flúor. Foram confeccionados 6 corpos-de-prova do cimento de ionômero de vidro modificado por resina (Vitremer/ 3M ESPE) como grupo controle e o mesmo número de corpos-de-prova para cada grupo em que foi proposta a aplicação do primer (Vitremer Primer/ 3M ESPE) ou sistema adesivo (Single Bond/3M ESPE e Prime Bond 2.1/ Dentsply Brasil). Os corpos-de-prova foram submetidos à ciclagem de pH, permanecendo 6 horas em solução desmineralizante (pH 4,3) e 18 horas em solução remineralizante (pH 7,0) a cada 24 horas, por um período de 15 dias. Os resultados foram avaliados pelo teste ANOVA e teste de Tukey (p<0,05). Uma segunda etapa foi realizada in situ para analisar o efeito da capacidade de inibir a desmineralização de esmalte bovino. Após as informações aos voluntários, o estudo foi conduzido por 15 dias. Sessenta fragmentos de dentes bovinos (4x4x2mm) foram restaurados com as mesmas associações propostas, os quais foram distribuídos em dispositivos palatinos intra-bucais para o uso por 10 voluntários. Uma solução de sacarose de 20% foi gotejada 8 vezes ao dia. Para esta comparação, foi procedida a análise de microdureza longitudinal (Knoop). Os resultados foram analisados estatisticamente por ANOVA a três critérios e Tukey para a comparação dos resultados entre os grupos, distância e profundidade após o desafio cariogênico (p<0,05). Na terceira etapa, foi realizada uma avaliação do comportamento clínico de restaurações cervicais de lesões não cariosas. Foram considerados o baseline e os períodos de 6 meses e 1 ano. A avaliação foi realizada por 2 examinadores pré-calibrados, utilizando o método USPHS modificado, enfatizando os itens de retenção, integridade marginal, descoloração marginal, reincidência de cárie, e sensibilidade pós-operatória, cor e textura superficial. Para a análise estatística foi aplicado o teste de Qui-quadrado e McNemar com p<0,05. Os resultados revelaram interferência dos sistemas adesivos na redução da capacidade de liberação de flúor. Na análise de microdureza e na avaliação clínica não houve diferenças entre os tratamentos considerados em nenhuma das categorias avaliadas. Os resultados obtidos permitiram a aceitação parcial das hipóteses nulas consideradas. / This study tested the null hypothesis that one-bottle adhesive systems do not influence fluoride release, inhibition of demineralization and clinical performance of a resin modified glass ionomer cement. An in vitro study was conducted to verify adhesive coat influence on fluoride release. Six specimens of resin modified glass ionomer cement (Vitremer/ 3M ESPE) were made for control group and for each test group coated with primer (Vitremer Primer/ 3M ESPE) or adhesive system (Single Bond/ 3M ESPE or Prime Bond 2.1/ Dentsply Brasil. Specimens were immersed in demineralization solution for 6 hours followed by immersion in remineralization solution for 18 hours totalizing 15-day cycle. Data were analyzed by ANOVA and Tukey tests (p<0,05). An in situ protocol was performed to evaluate this association on the ability of inhibition of demineralization on bovine enamel. The study was conducted for 15 days after volunteers received instructions. Sixty blocks of bovine teeth (4x4x2mm) were restored with the same systems, which were randomly distributed in intraoral acrylic appliances to be used for 10 volunteers. A 20% sucrose solution was dropped on the blocks eight times a day. Longitudinal microhardness (Knoop) was employed to obtain the results after the test, which were analyzed by three criteria ANOVA and Tukey test, considering distance, deepness and material (p<0.05). Finally, a clinical evaluation of noncarious cervical lesions restored with these associations was made, considering baseline, sixmonth and 1-year performances. Evaluation was made by two pre-calibrated examiners using modified USPHS criteria, focusing retention, marginal integrity, marginal discoloration, caries recurrence, postoperative sensitive, color and surface texture. Results were submitted to statistical analysis (Qui-square and McNemar, p<0.05). Analysis of results showed reduction of fluoride release when these associations were employed. Microhardness evaluation and clinical performance did not reveal differences of pattern of inhibition of demineralization. The results led to partial acceptability of the null hypothesis.
204

Resistência de união à microtração entre camadas de materiais restauradores de diferentes matrizes / Bond strength between layers of silorane and methacrylate-based materials

Salazar, Yvette Alania 06 June 2011 (has links)
A resina de silorano e a sua polimerização catiônica apresentam diferenças quanto aos materiais a base de metacrilato. Como materiais restauradores, estes poderiam ser utilizados juntos, no entanto suas moléculas diferentes poderiam provocar incompatibilidade. Por isso é importante avaliar a união interfacial desses materiais tendo como objetivo a comparação da resistência de união a microtração entre camadas de Filtek P90 aderidas a Filtek Z350, Filtek P90 ou Vitremer utilizando Adper Single Bond 2 ou o Sistema Adesivo P90. Os substratos dos espécimes a serem testados foram fabricados utilizando uma matriz de silicone (5mm x 5mm x 2.5mm) e fotoativados por 40 segundos (Blue Star 3, Microdont; 1076mW/cm2). De acordo com o grupo testado, foi usada ou não uma camada de adesivo fotoativado por 10 segundos. O segundo substrato (2,5mm) foi aplicado e fotoativado por 40 segundos. Os espécimes foram secionados com formato de palito, com uma área de 0,64mm2, e armazenados em água destilada a 37ºC por 24 horas. Realizou-se o teste de microtração utilizando a máquina de ensaios universal com uma velocidade de 0,5mm/min. Foi analizado o tipo de fratura resultante. Os resultados foram analisados utilizando ANOVA e o teste de Tukey (p<0.05). A média e desvio-padrão dos resultados da resistência de união em MPa são: G1 Pad (P90/adesivo P90/P90) 50.9±15.3, G2 P (P90/sem adesivo/P90) 40.2±10.2, G3 Z (Z350/sem adesivo/Z350) 62.1±15.2, G4 Ppol (P90/sem adesivo, tira de poliéster/P90) 28.8±9.2, G5 ZadP (Z350/adesivo P90/P90) 62.1±8.2, G6 PSBZ (P90/Single Bond 2/Z350) 37.1±12.5, G7 ZSB (Z350/Single Bond 2/Z350) 54.3±12.3, G8 VitrZ (Vitremer/Single Bond 2/Z350) 37.4±7.4 e G9 VitrP (Vitremer/adesivo P90/P90) 34.9±4.1. Diferença significativa foi observada entre os grupos G2 e G3, e G5 e G6. Não foi observada diferencia significativa entre os grupos G8 e G9, G5 e G7, G1 e G6. Dentro das limitações do estudo, pode-se concluir que a resina de silorano demonstrou propriedades de adesão similares quando aderida com resina de metacrilato. Valores significativamente menores foram observados entre camadas de P90 (G2) quando comparados com Z350 (G3). / Silorane resin and its cationic polymerization are different from resin-based materials. As restorative materials, their use together could cause some incompatibility that raises the question about the importance of interfacial bonding properties. This study aimed to compare the microtensile bond strengths between layers of Filtek P90 bonded with itself, Filtek Z350 or Vitremer using Adper Single Bond 2 and P90 Adhesive System. Initially, substrates for the testing specimens were fabricated using a silicone mold (5mm x 5mm x 2.5mm) and light-cured for 40 s (Blue Star 3, Microdont; 1076mW/cm2). According to the testing group, it was used or not an adhesive layer, light-cured for 10 s. The second increment (2.5mm) was cured for 40 s. The specimens were sectioned in beams with 0.64mm2 cross-sectional area and stored in distilled water at 37ºC for 24 h. Microtensile bond strength test was performed using a universal testing machine with a 0.5mm/min crosshead speed. Failure modes were assessed. Values were calculated in MPa. Data were analyzed with ANOVA and Tukeys post-hoc tests at a 5% significance level. Microtensile bond strength means and standard deviation are: G1 Pad (P90/P90 adhesive/P90) 50.9±15.3, G2 P (P90/without adhesive/P90) 40.2±10.2, G3 Z (Z350/without adhesive/Z350) 62.1±15.2, G4 Ppol (P90/without adhesive, polyester strip/P90) 28.8±9.2, G5 ZadP (Z350/P90 adhesive/P90) 62.1±8.2, G6 PSBZ (P90/Single Bond 2/Z350) 37.1±12.5, G7 ZSB (Z350/Single Bond 2/Z350) 54.3±12.3, G8 VitrZ (Vitremer/Single Bond 2/Z350) 37.4±7.4 e G9 VitrP (Vitremer/P90 adhesive/P90) 34.9±4.1. Significant difference was showed among G2 and G3, G5 and G6. No significant difference was found between G8 and G9, G5 and G7, G1 and G6. Conclusions: Within the limitations of this study, it can be concluded that silorane composite showed similar bonding properties when bonded with methacrylate-based materials. Significantly lower bond strength was observed between layers of P90 than of Z350.
205

"Efeito de tratamentos de limpeza na resistência adesiva de sistemas autocondicionantes ao esmalte dental íntegro e em contato com saliva humana" / Cleaning treatment effects on self-etching adhesive bonding strength to unground dental enamel after salivary contact

Vega, Ana Del Carmen Armas 13 September 2005 (has links)
Esta pesquisa avaliou o efeito de diferentes técnicas de limpeza aplicadas na superfície de esmalte intacto, na resistência adesiva de resina composta usando sistemas adesivos self etch. Coroas dentais foram cortadas e obtidos 90 fragmentos (n=10), cujas superfícies de esmalte permaneceram em contacto com saliva humana fresca por 1 hora, recebendo a seguir de acordo com o grupo, limpeza com uma das seguintes técnicas: pasta de pedra pomes/água seguida de detergente aniônico Tergensol (PP), jato de bicarbonato de sódio (B), ou spray ar/água (C). Após limpeza, um dos sistemas adesivos foi aplicado: Clearfil SE Bond (CF), Adper Prompt (AD) ou Scotchbond Multi-Purpose (SB), realizando-se um bloco de resina composta Z250 de 4 ou 5 mm sobre o adhesivo dental. Após 24 horas de armazenagem, os corpos de prova foram cortados em maquina Labcut, originando palitos com área adesiva de aproximadamente 1 mm 2 . Cada palito foi adaptado em um dispositivo de tração, para serem realizados os testes de resistência adesiva. A análise estadística, considerando a cada palito como unidade amostral, e os tipos de fraturas apresentadas, mostrou ausência de diferença entre os sistemas adesivos usados. Entre as técnicas de limpeza testadas, valores de RMT foram superiores para a técnica de PP, não se encontrando diferenças estatisticamente significantes entre B e C. A análise ao MEV da interface esmalte/resina confirmou os resultados estatísticos encontrados e permitiu observar que a interação resina adhesiva/esmalte ocorre de maneira diferente entre os sistemas self etch e all etch. Concluiu-se que, a técnica PP constitui uma opção adequada de limpeza de superfícies de esmalte liso intacto e que a técnica de bicarbonato pode afetar a resistência adesiva destas superfícies. / This study evaluated the effect of different cleaning techniques in the adhesive bond strength of self-etching bonding systems to unground enamel after being in contact with human saliva. Ninety enamel fragments were obtained from dental crowns (n = 10) and the enamel surface of each fragment were kept in contact with fresh human saliva for 1 hour. Next, they received the cleaning treatment according to the group as follows: pumice and water paste followed by anionic detergent - Tergensol (PP), sodium bicarbonate jet (B), or air/water spray (control group - C). After cleaning procedures, one of the bonding systems was applied: Clearfil SE Bond (CF), Adper Prompt (AD), or Scothbond Multi-Purpose (SB), and a Z250 composite resin bloc with 4 or 5 mm was built above the dental adhesive. After 24 hours of storage, the specimens were sectioned to obtain sticks with cross sectional areas of approximately 1 mm². The sticks were submitted to microtensile test in an Instron testing machine. Statistical analysis of the results, considering each stick as a sample unit and the fracture kinds presented, showed no statistical significant difference in mean shear bond strength among the bonding systems used. Regarding to the cleaning techniques, shear bond strength values were superior for PP and there was no significant statistical difference between B and C. The interface enamel/dentin SEM analysis corroborated the statistical results I was concluded that PP method is appropriate for cleaning unground enamel surface after salivary contact, improving bond strength of all etch and self etch adhesive systems, and that cleaning with sodium bicarbonate jet may affect the bonding strength of these surfaces.
206

Efeito da variação dos parâmetros de potência e energia por pulso na resistência de união à dentina de sistema adesivo irradiado com laser de diodo / Effect of the variation of the parameters of output power and pulse energy on bond strength to dentin irradiated of conventional adhesive system with diode laser

Cruz, Adriana Regina 08 November 2016 (has links)
O uso do laser previamente à polimerização de sistemas adesivos aplicados sobre a dentina tem sido proposto para melhorar a resistência de união à dentina. O objetivo foi avaliar o efeito da variação da potência (P) e da energia por pulso (Ep) na resistência de união à dentina de um sistema adesivo convencional irradiado com laser previamente à fotoativação. Duzentos terceiros molares foram distribuídos aleatoriamente em 10 grupos (n=20) sendo um grupo sem irradiação (Controle) e nove grupos irradiados com laser de Diodo (970 nm) (SiroLaser - Sirona Dental Systems - Benshein, Alemanha), de acordo com a potência (P) e energia por pulso (Ep) utilizados: 1 - 0,5W/0,05J; 2 - 0,5W/0,08J; 3 - 0,5W/0,1J; 4 - 0,8W/0,05J; 5 - 0,8W/0,08J; 6 - 0,8W/0,1J; 7 - 1W/0,05J; 8 - 1W/0,08J; 9 - 1W/0,1J. Em todos os grupos fez-se o condicionamento com ácido fosfórico, aplicação do sistema adesivo convencional de dois passos AdperTM Single Bond 2 (3M ESPE, St Paul, MN, EUA) e restauração com resina composta Z250 (3M). Para avaliar a resistência de união foi realizado teste de microtração obtendo-se os valores em MPa. Os resultados foram analisados pelo ANOVA a dois critérios, seguido de Dunnett t (p < 0,001) para comparação entre os grupos. Os grupos irradiados foram avaliados pelo ANOVA a um critério, seguido dos testes de comparações múltiplas Bonferroni e Tamhane. Os valores de resistência de união ± desvio padrão de todos os grupos foram, respectivamente: 0 - Controle (34,60±10,76); 1 - (19,62±8,65); 2 - (27,56±9,20); 3 - (30,34±7,92); 4 - (23,31±5,96); 5 - (20,93±7,46); 6 - (24,67±8,59); 7 - (23,61±7,04); 8 - (25,94±6,82) e 9 - (21,48±3,59). O laser de Diodo influencia na resistência de união entre os grupos irradiados e não irradiado. A potência de 0,5W e energia por pulso de 0,1J influenciam positivamente nos valores de resistência de união quando o sistema adesivo é irradiado previamente a sua fotoativação. / The use of the laser prior to polymerisation of adhesive systems applied to the dentin has been proposed to improve the bond strength of dentin. The aim of this study was to investigate the effect of the variation of the output power (P) and pulse energy (Ep) on bond strength to dentin irradiated of conventional adhesive system with laser. Two hundred third molars were randomly distributed in 10 groups (n = 20): a group without laser irradiation (group control) and nine groups irradiated with diode laser (970 nm) (SiroLaser Sirona Dental Systems-Benshein, Germany), according to the output power (P) and pulse energy (Ep): 1 - 0,5W/0,05J; 2 - 0,5W/0,08J; 3 - 0,5W/0,1J; 4 - 0,8W/0,05J; 5 - 0,8W/0,08J; 6 - 0,8W/0,1J; 7 - 1W/0,05J; 8 - 1W/0,08J; 9 - 1W/0,1J. It was used in all groups etching with phosphoric acid, application of conventional adhesive system AdperTM Single Bond 2 (3M ESPE, St. Paul, MN, USA) and restoration with composite resin Z250 (3M). Microtensile test was performed obtaining bond strength values in MPa. Results were analyzed by two-ways ANOVA test, followed by Dunnett t (p < 0.001) for comparison between groups. The groups laser irradiated were assessed by one-way ANOVA test and subsequent t test with Bonferroni and Tamhane corrections. Bond strength values ± standard deviation for the groups were, respectively: 0 group control (34.60 ± 10.76); 1 - (19.62 ± 8.65); 2 - (27.56 ± 9.20); 3 - (30.34 ± 7.92); 4 - (23.31 ± 5.96); 5 - (20.93 ± 7.46); 6 - (24.67 ± 8.59); 7 - (7.04 ± 23.61); 8 - (25.94 ± 6.82) and 9 - (3.59 ± 21.48). The Diode laser influences on bond strength between irradiated and without irradiated groups. The output power 0.5W and energy per pulse 0.1J influence positively in the bond strength values when the adhesive system is irradiated prior to their light curing.
207

Avaliação da resistência de emendas dentadas para madeira laminada colada / Evaluation of the resistance in finger joints for glulam

Marin, Cristiane Prado 11 April 2006 (has links)
Uma das técnicas para viabilizar a utilização de madeira de reflorestamento é a fabricação de Madeira Laminada Colada (MLC), que consiste na colagem de lâminas de madeira. Essas lâminas são obtidas da união de peças, por meio de emendas dentadas coladas. Para um bom desempenho de estruturas de MLC, a escolha do adesivo é fundamental. Atualmente, o Cascophen é o adesivo mais utilizado. Nesse contexto, o objetivo dessa pesquisa foi avaliar a eficiência, quanto à resistência à tração de emendas dentadas, de adesivos (Cascophen, Wonderbond, Cascorez, Melaminauréia formaldeído e Poliuretano à base de óleo de mamona) na colagem de madeira da espécie Pinus hondurensis, utilizando um padrão de emenda com perfil vertical. Também foram feitas comparações entre os perfis vertical e horizontal usando apenas o adesivo Cascophen. Os trabalhos experimentais foram baseados em ensaios de tração em peças com dimensão estrutural. Foram testadas 150 peças emendadas e 25 peças sem emendas (para comparações), com dimensões nominais de 3,5 x 7 x 200 cm. As principais análises feitas foram as comparações entre todos os adesivos com perfil vertical e entre os perfis vertical e horizontal, e uma análise dos modos de ruptura e suas relações com a porcentagem de madeira de inverno e o módulo de elasticidade. A comparação entre todos os adesivos com perfil vertical revelou que apenas o Cascophen e o Cascorez não possuem diferenças estatísticas. O adesivo que mais se destacou foi o Wonderbond, que teve desempenho superior ao do Cascophen, inclusive. Também se concluiu que não existe diferença estatística significativa na resistência à tração dos perfis vertical e horizontal / One of the techniques to allow for the use of reforestation lumber is the production of glued laminated timber (glulam), which consists of the gluing of lumber laminas. Those laminas are obtained of the union of pieces, through glued finger joints. For a good performance of glulam structures, the choice of the adhesive is fundamental. Traditionally, Cascophen is the most adhesive used in the production of glulam. In that context, the aim of the present research is to evaluate the efficiency, with relation to the strength, of adhesives (Cascophen, Wonderbond, Cascorez, Melamine urea formaldehyde and castor oil Polyurethane) in the gluing of Pinushondurensis lumber, using a joint pattern with vertical profile. Comparisons between the vertical and horizontal profiles using only Cascophen adhesive were made. The experimental analyses were based on tensile tests in pieces with structural dimension. For this purpose, 150 joint pieces and 25 pieces without joints (for comparisons) with nominal dimensions of 3,5 x 7,0 x 200 cm were tested. The main analyses performed were the comparison among all the adhesives with vertical profile, the comparison between the vertical and horizontal profiles for the Cascophen adhesive and, finally, an analysis of the failure modes and their relations with both latewood percentage and elasticity modulus. The comparison among all the adhesives with vertical profile revealed that Cascophen and Cascorez do. Not have statistical differences. The best adhesive was Wonderbond, which had a better performance than Cascophen. Concerning the vertical and horizontal profiles, no significant statistical difference was found in the tensile strength
208

Influência da incorporação de vidro bioativo em diferentes propriedades de sistemas adesivos /

Costa, Joatan Lucas de Sousa Gomes January 2019 (has links)
Orientador: Alessandra Nara de Souza Rastelli / Resumo: O presente estudo teve como objetivo avaliar o efeito da adição de micropartículas (MPs) de vidro bioativo F-18 em diferentes concentrações em três sistemas adesivos sobre o grau de conversão, a umectabilidade e a resistência adesiva dos mesmos, assim como o padrão de falha. Os sistemas adesivos AdperTM ScotchTM Bond Multi Purpose (A), AdperTM Single Bond (3M ESPE) (S), e Clearfil SE Bond (Kuraray) (C) foram modificados com concentrações de 0 (controle), 1, 2 e 5% de vidro bioativo F-18. Adicionalmente, a distribuição e dispersão das partículas do vidro bioativo foram verificadas por microscopia eletrônica de varredura (MEV). Para o grau de conversão, se obtiveram espectros de absorção dos sistemas adesivos curados e não curados. Para o teste da umectabilidade, os sistemas adesivos modificados ou não foram dispensados sobre as superfícies dentinárias de dentes bovinos, e os ângulos de contato foram mensurados por meio de goniômetro. Para o teste de microcisalhamento, foram confeccionados espécimes em resina composta em substrato bovino, sobre os quais os sistemas adesivos, modificados ou não, foram aplicados, sendo feitas as análises de resistência adesiva após 24 horas. O padrão de falha dos espécimes foi analisado em lupa estereoscópica e por microscopia eletrônica de varredura (MEV). Os resultados foram obtidos e analisados pelo teste de Análise de Variância ANOVA (2 fatores) com pós teste Tukey. Foi observado que não houve diferenças entre os grupos controle e modificados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the effect of the incorporation of F-18 bioactive glass microparticles (MPs) in different concentrations in three adhesive systems on the degree of conversion, wettability and adhesive strength, as well as the failure pattern. Adper™ Scotch™ Bond Multi Purpose, Adper™ Single Bond (3M ESPE), and Clearfil SE Bond (Kuraray) adhesive systems were modified with concentrations of 0 (control), 1, 2 and 5% F-18 bioactive glass. In addition, the distribution and dispersion of bioactive glass particles were verified by scanning electron microscopy (SEM). For the degree of conversion, absorption spectra of cured and uncured adhesive systems were obtained. For the wettability test, adhesive systems modified or not were dispensed on the dentin surfaces of bovine teeth, and the contact angles were measured by goniometer. For the microshear test, specimens were made in composite resin on bovine substrate, on which adhesive systems, modified or not, were applied, and the adhesive strength tests were done after 24 hours. The failure pattern of the specimens was analyzed in a stereoscopic magnifying glass and by scanning electron microscopy (SEM). The results were obtained and analyzed by ANOVA Variance Analysis (2 factors) with Tukey test. It was observed that there were no differences between the control and modified groups (p> 0.05). The predominant failure pattern was adhesive. It was concluded that the addition of F-18 bioactive glass microparticles did not in... (Complete abstract click electronic access below) / Mestre
209

Resistência de união à dentina de sistemas adesivos irradiados com laser de diodo: estudo in vitro / Bond strength to dentin with adhesive systems irradiated with diode laser: in vitro study

Maenosono, Rafael Massunari 26 March 2013 (has links)
A irradiação LASER sobre os sistemas adesivos aplicados em dentina, antes de sua fotoativação, tem sido proposta para aumentar a resistência de união de restaurações adesivas. O objetivo foi avaliar o efeito da irradiação com LASER de Diodo (&#x3BB; = 970nm) sobre diferentes sistemas adesivos na resistência de união imediata à dentina. Oitenta molares humanos hígidos foram aleatoriamente distribuídos em 8 grupos (n=10) de acordo com o sistema adesivo: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus - convencional não simplificado), SB (Adper&#x2122; SingleBond 2 - convencional simplificado), CSE (Clearfil&#x2122; SE Bond - autocondicionante não simplificado), EO (Adper&#x2122; EasyOne - autocondicionante simplificado); e respectivos grupos irradiados com LASER de Diodo (SiroLaser, Sirona Dental). Para avaliar a resistência de união foi realizado teste de microtração, obtendo-se valores em MPa, posteriormente analisados através de ANOVA a 2 critérios, seguido de Tukey para comparações individuais e múltiplos testes t (p<0,05) para comparações entre CONTROLE e LASER do mesmo sistema adesivo. Os valores de resistência de união ± desvio padrão para os grupos sem e com irradiação com LASER foram respectivamente: MP (40,10±10,95 / 35,82±7,17), SB (33,49±6,77 / 43,69±8,15), CSE (43,71±15,71 / 37,95±7,66) e EO (19,67±5,86 / 29,87±6,98). A irradiação com LASER de Diodo provocou um aumento da resistência de união obtida pelos sistemas adesivos SB e EO, mostrando-se uma técnica promissora na obtenção de uma adesão mais efetiva de sistemas adesivos simplificados ao substrato dentinário. / LASER irradiation on adhesive systems before it`s activation has been proposed to increase bond strength of composite restorations to dentin. The objective was to evaluate the effect of Diode LASER irradiation (&#x3BB; = 970nm) on different adhesive systems on immediate bond strength to dentin. Eighty healthy human molars were randomly distributed in 8 groups (n=10) according to the adhesive system: MP (Adper&#x2122; ScotchBond Multi-Purpose Plus, non simplified etch and rinse), SB (Adper&#x2122; SingleBond 2 simplified etch and rinse), CSE (Clearfil&#x2122;SE Bond non simplified self-etch), EO (Adper&#x2122; EasyOne simplified self-etch); and respective groups irradiated with Diode LASER (SiroLaser, Sirona Dental). Microtensile test was performed obtaining bond strength values in MPa whice were analyzed by two way ANOVA, followed by Tukey for individual comparisons and multiple t test (p<0.05) for evaluation of CONTROL and LASER groups with the same adhesive systems. Bond strength values ± standard deviation for groups without and with LASER irradiation were respectively: MP (40.10±10.95 / 35.82±7.17), SB (33.49±6.77 / 43.69±8.15), CSE (43.71±15.71 / 37.95±7.66) and EO (19.67±5.86 / 29.87±6.98). Irradiation with Diode LASER resulted in an increase of SB and EO bond strength values, being considered a promising technic to obtain an improved adhesion of simplified adhesive systems to dentin substrate.
210

Influência do uso do primer de um cimento de ionômero de vidro modificado por resina na adesão à dentina de sistemas adesivos convencional e auto-condicionantes / Influence of a resin-modified glass ionomer cement primer on the microtensile strength of conventional and self-etching adhesive systems to dentin

Regalado, Diego Ferreira 23 May 2003 (has links)
O objetivo desse trabalho foi determinar o efeito do primer do cimento de ionômero de vidro modificado por resina, na resistência de união através de testes de microtração, de sistemas adesivos convencionais e autocondicionantes à dentina. O plano oclusal dentinário dos dentes terceiros molares humanos extraídos foi cortado na máquina de corte e depois preparado usando lixa de papel de granulação nos. 80, 320 e 600 com irrigação. Estes dentes foram divididos nos seguintes grupos: GRUPO 1 – ácido fosfórico a 35 % + sistema adesivo Single bond + resina Z-250 controle); GRUPO 2 - sistema adesivo autocondicionante One Up Bond F + resina Z-250 (controle); GRUPO 3 - primer + ácido fosfórico a 35 % por 15 s + sistema adesivo Single bond + resina Z-250; GRUPO 4 - primer + ácido fosfórico a 35 % por 30 s + sistema adesivo Single bond + resina Z-250; GRUPO 5 – primer + sistema adesivo autocondicionante One Up Bond F + resina Z-250. Foram preparados espécimes em forma de bastões de 1.0 × 1.0 mm de resina composta e submetidos ao teste de microtração à velocidade de 1.0 mm/ min em uma máquina de ensaio universal. Os resultados e respectivos desvios-padrão foram: GRUPO 1- 22.56 ± 6.43 MPa; GRUPO 2 - 22.51 ± 6.14 MPa; GRUPO 3 -19.24 ± 5.38 MPa; GRUPO 4 - 22.01 ± 6.23 MPa; GRUPO 5 - 24.95 ± 7.46 MPa.. Após análise estatística pelos testes ANOVA a um critério e teste de Tukey foi possívelconcluir que o primer do cimento de ionômero de vidro modificado por resina interfere na resistência adesiva à microtração dos sistemas adesivos convencionais, mas não altera a resistência adesiva à dentina dos adesivos autocondicionantes. / The purpose of this study is to determine the influence of the resin-modified glass ionomer cement primer on the microtensile strength of conventional and self-etching adhesive systems to dentin. Flat occlusal dentin surfaces of extracted human third molars were prepared using wet SiC paper from # 80, 320 and 600 and divided into the followed groups: GROUP 1 – Phosphoric acid 35 % + Single bond bonding system + Z-250 resin composite (group control) ; GROUP 2 - One up bond F self-etching adhesive + Z-250 resin composite (group control); GROUP 3 - primer + Phosphoric acid 35 % for 15 s + Single bond bonding system + Z-250 resin composite; GROUP 4 - primer + Phosphoric acid 35 % for 30 s + Single bond bonding system + Z-250 resin composite; GROUP 5 – primer + One up bond F self-etching adhesive + Z- 250 resin composite. Resin composite – dentin beams with areas on average of 1.0 mm2 were prepared and submitted to the microtensile test at a crosshead speed of 1.0 mm/min. Results of the microtensile test were: GROUP 1 - 22.56 ± 6.43 MPa; GROUP 2 - 22.51 ± 6.14 MPa; GROUP 3 - 19.24 ± 5.38 MPa; GROUP 4 - 22.01 ± 6.23 MPa; GROUP 5 - 24.95 ± 7.46MPa. The mean bond strengths were statiscally analyzed by a one-way ANOVA and Tukey tests which allowed to conclude that the resin-modified glass ionomer cement primer decreases the microtensile bond strengths of conventional adhesive system to dentin. The bond strengths of self-etching adhesive system to dentin were not altered by the presence of the primer.

Page generated in 0.0386 seconds