• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 814
  • 25
  • 24
  • 24
  • 23
  • 15
  • 14
  • 14
  • 8
  • 7
  • 7
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 848
  • 320
  • 276
  • 251
  • 215
  • 202
  • 194
  • 192
  • 189
  • 181
  • 170
  • 164
  • 157
  • 123
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Influência do tratamento de superfície em vitrocerâmica à base de dissilicato de lítio na resistência adesiva com cimento resinoso dual = Influence of surface treatment on bond strength in lithium dislicate gass-ceramic to a dual-cured resin cement / Rafael Torres Brum ; orientador, Danilo Biazetto de Menezes Caldas / Influence of surface treatment on bond strength in lithium dislicate gass-ceramic to a dual-cured resin cement

Brum, Rafael Torres January 2009 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009 / Inclui bibliografias / Objetivo: Avaliar o tratamento de superfície em vitrocerâmica a base de dissilicato de lítio na resistência adesiva com cimento resinoso dual. Materiais e Método: 60 espécimes (20 x 5 x 2 mm) de vitrocerâmica foram fabricados seguindo as orientações do fa / Objective: To assess the influence of surface treatment on bond strength in a lithium disilicate based glass-ceramic to a dual-cured resin cement. Materials and Methods: Sixty glass-ceramics specimens (20 x 5 x 2 mm) were hot pressed according to manufact
242

Efeito do modo de ativação de sistemas adesivos na resistência flexural e no módulo de elasticidade de compósitos reforçados por fibras / Luciano Mundim de Camargo ; orientador, Rodrigo Nunes Rached ; co-orientadora, Evelise Machado de Souza

Camargo, Luciano Mundim de January 2012 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / Objetivo: Comparar o efeito de sistemas adesivos fotoativados e de ativacao dual na resistencia flexural e no modulo de elasticidade de compositos reforcados por fibras (CRFs). Materiais e Metodos: Cento e sessenta especimes (25 x 2 x 2 mm) divididos em s / Objective: To compare the effect of light activated and dual activation adhesive systems on the flexural strength and elastic modulus of fiber-reinforced composites (FRCs). Materials and Methods: A total of 160 specimens (25 x 2 x 2 mm) divided into six e
243

Força de adesão de um cimento de ionômero de vidro modificado por resina em meio contaminado com saliva : avaliação in vitro de diferentes preparos do esmalte / Juliana Godoy-Bezerra ; orientador, Sérgio Vieira ; co-orientador, José Henrique G. de Oliveira

Godoy-Bezerra, Juliana January 2004 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2004 / Inclui bibliografia / O ionômetro de vidro modificado por resina usado na colagem de brackets atua prevenindo a desmineralização do esmalte e permite colagem em meio úmido, no entanto com forças de adesão inferiores às resinas. Este estudo se propôs a avaliar a força de adesão
244

Análise citológica da mucosa bucal, adjacente a brackets e ligaduras metálicas ou elásticas, = Cytologic analysis of the oral mucosa adjacent to brackets and metal or elastic ligatures / Raul Magnoler Sampaio Mei ; orientadora, Elisa Souza Camargo ; co-orientador, Antônio Adilson Soares de Lima / Cytologic analysis of the oral mucosa adjacent to brackets and metal or elastic ligatures

Mei, Raul Magnoler Sampaio January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / Objetivos: Avaliar pela citologia esfoliativa em base líquida possíveis alterações citológicas das células epiteliais adjacentes a acessórios ortodônticos. Design do Estudo: Em 20 indivíduos foram colados brackets nos pré-molares superiores e amarrados fi / Objectives: Evaluate the possible cytological alterations of epithelial cells adjacent to orthodontic accessories by liquid-based exfoliative cytology. Study Design: In 20 individuals, brackets were bonded to the maxillary premolars, and wires were tied w
245

Resistência flexural de resinas compostas submetidas ao aquecimento pré e pós-polimerização / Carolina Ferreira Rocha ; orientador, Danilo Biazzetto de Menezes Caldas

Rocha, Carolina Ferreira January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / O objetivo deste estudo in vitro foi avaliar a resistência flexural de resinas compostas submetidas a aquecimento pré e pós-polimerização. Noventa espécimes das resinas TetricÒ Ceram, CharismaÒ e Cristobal+Ò, de (25 mm x 2 mm x 2 mm), foram confeccionados
246

Sínteses de adesivos de ureia-formaldeído com adição de lignina kraft e celulose nanocristalina / Synthesis of urea-formaldehyde adhesives with the addition of kraft lignin and nanocrystalline cellulose

Ferreira, Juliana Ceccato 02 March 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-04-06T16:32:04Z No. of bitstreams: 1 texto completo.pdf: 1740038 bytes, checksum: f6b32f1471363b3db5a90aff0f364430 (MD5) / Made available in DSpace on 2017-04-06T16:32:04Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1740038 bytes, checksum: f6b32f1471363b3db5a90aff0f364430 (MD5) Previous issue date: 2017-03-02 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O adesivo de ureia-formaldeído é um dos adesivos sintéticos mais utilizados no mundo para a fabricação de painéis de madeira. Apesar da sua ampla importância econômica e o longo histórico de utilização, o mesmo possui baixa resistência à umidade, emissão de formaldeído e menor resistência mecânica quando comparado a outros adesivos sintéticos. Pesquisas para minimizar estes efeitos estão sendo realizadas, principalmente no que tange a adição de nanopartículas aos adesivos, com o intuito de melhorar suas propriedades e o desempenho na colagem. Em relação à síntese do adesivo ureia- formaldeído é possível trabalhar no controle de variáveis do processo como o pH, tempo e temperatura da reação, razão molar formaldeído:ureia, pureza dos reagentes, dentre outros. Entre os aditivos, a lignina kraft e a celulose nanocristalina se destacam pois são considerados biopolímeros de alta tecnologia para aplicação em diversos materiais, pela alta resistência, rigidez e alta disponibilidade na natureza. Estes materiais são renováveis e biodegradáveis, o que lhes permite competir com produtos fósseis e industrializados. Os objetivos deste trabalho foram sintetizar adesivos de ureia- formaldeído com adição de lignina kraft e celulose nanocristalina. O trabalho está dividido em quatro capítulos, a saber: Capítulo 1 – Adição de lignina kraft ao adesivo ureia-formaldeído para a colagem de madeira sólida e reconstituída. Capítulo 2 – Efeito da razão molar e tempo de reação sobre a síntese do adesivo ureia-formaldeído. Capítulo 3 – Adição de lignina kraft metiolada na síntese de adesivos ureia-formaldeído. Capítulo 4 – Efeito da adição de celulose nanocristalina na síntese de adesivos ureia- formaldeído. A adição de 5% de lignina ao adesivo proporcionou a maior resistência ao cisalhamento e porcentagem de falha na madeira, assim como boas propriedades adesivas. A redução do tempo de gelatinização e do tempo de trabalho dos adesivos com a adição da lignina é satisfatório, possibilitando a redução da adição de catalisador em contrapartida com a adição de um produto renovável. Adições de 10% de lignina kraft ao adesivo proporcionaram os melhores resultados para o conjunto dos ensaios mecânicos de painéis MDP (Capítulo 1). A razão molar formaldeído:ureia e tempo de reação na etapa de condensação afetaram significativamente as propriedades dos adesivos sintetizados. O adesivo sintetizado com razão molar de 1,26:1,0 e 20 minutos de reação na etapa de condensação apresentou as melhores propriedades adesivas e resistência ao cisalhamento comparável ao adesivo comercial (Capítulo 2). Em relação ao aumento da reatividade da lignina kraft, a lignina metiolada tipo 1 (mistura de 29,45 g de lignina com 58,9 g de água e 27 g de formaldeído, com ajuste do pH para 12), proporcionou ao adesivo lignina-ureia-formaldeído propriedades adesivas mais adequadas quando comparadas às sínteses que utilizaram a lignina metiolada tipo 2 (mistura de lignina e formaldeído em proporções de 1:1, com ajuste do pH para 8,5). No entanto, o adesivo com adição de 10% de lignina metiolada tipo 2 na síntese do adesivo lignina-ureia-formaldeído apresentou a maior resistência ao cisalhamento na linha de cola de juntas de lâminas coladas (Capítulo 3). Adições de 2, 4 e 6% de celulose nanocristalina ao adesivo ureia-formaldeído proporcionaram um aumento gradativo da viscosidade, pH, teor de sólidos e tempo de gelatinização, em comparação à síntese adesiva sem adição de celulose nanocristalina. Acima disso houve uma redução nos valores. Adição de 4% de celulose nanocristalina ao adesivo proporcionou a maior resistência ao cisalhamento na linha de cola e a maior porcentagem de falha na madeira, entre os adesivos testados. No entanto, as sínteses adesivas de ureia-formaldeído e celulose nanocristalina-ureia-formaldeído apresentaram resultados físicos e mecânicos para os painéis inferiores aos obtidos para os painéis MDP produzidos com adesivo comercial de ureia-formaldeído (Capítulo 4). / The urea-formaldehyde adhesive is one of the most widely used synthetic adhesives in the world for the manufacture of wood panels. Despite its wide economic importance and long usage history, it has low resistance to moisture, formaldehyde emission and lower mechanical resistance when compared to other synthetic adhesives. Researches to minimize these effects are being carried out, mainly regarding the addition of nanoparticles to the adhesives, in order to improve their properties and the performance in bonding. In relation to the synthesis of the urea-formaldehyde adhesive, it is possible to work in the control of process variables such as pH, reaction time and temperature, molar ratio formaldehyde: urea, reagent purity, among others. Among the additives, kraft lignin and nanocrystalline cellulose stand out because they are considered high technology biopolymers for application in various materials, due to high strength, stiffness and high availability in nature. These materials are renewable and biodegradable, allowing them to compete with fossil and industrialized products. The objectives of this work were to synthesize urea-formaldehyde adhesives with addition of kraft lignin and nanocrystalline cellulose. The work is divided into four chapters, as follows: Chapter 1 - Addition of kraft lignin to the urea-formaldehyde adhesive for the bonding of solid and reconstituted wood. Chapter 2 - Effect of the molar ratio and reaction time on the synthesis of the urea-formaldehyde adhesive. Chapter 3 - Addition of methiolated kraft lignin in the synthesis of urea-formaldehyde adhesives. Chapter 4 - Effect of the addition of nanocrystalline cellulose on the synthesis of urea-formaldehyde adhesives. The addition of 5% lignin to the adhesive provided the highest shear strength and percentage of failure in the wood, as well as good adhesive properties. The reduction of the gelatinization time and the working time of the adhesives with the addition of the lignin is satisfactory, allowing the reduction of the addition of catalyst in return with the addition of a renewable product. Additions of 10% kraft lignin to the adhesive gave the best results for all mechanical assays of MDP panels (Chapter 1). The molar ratio formaldehyde: urea and reaction time in the condensation step significantly affected the properties of the synthesized adhesives. The 1.26: 1.0 and 20 minute molar ratio synthesized adhesive in the condensation step had the best adhesive properties and shear strength comparable to commercial adhesive (Chapter 2). In relation to the increase in the reactivity of kraft lignin, methiolate lignin type 1 (mixture of 29.45 g of lignin with 58.9 g of water and 27 g of formaldehyde, with adjustment of pH to 12) provided the lignin- Urea-formaldehyde more suitable adhesive properties when compared to the syntheses using methiolate lignin type 2 (mixture of lignin and formaldehyde in proportions of 1: 1, with pH adjustment to 8.5). However, the adhesive with the addition of 10% methyolated lignin type 2 in the synthesis of the lignin-urea- formaldehyde adhesive showed the highest shear strength in the glue line of bonded sheet joints (Chapter 3). Additions of 2, 4 and 6% of nanocrystalline cellulose to the urea-formaldehyde adhesive provided a gradual increase in viscosity, pH, solids content and gelatinization time, compared to the adhesive synthesis without addition of nanocrystalline cellulose. Above this there was a reduction in values. Addition of 4% of nanocrystalline cellulose to the adhesive provided the highest shear strength in the glue line and the highest percentage of wood failure among the adhesives tested. However, the adhesive syntheses of urea-formaldehyde and nanocrystalline-urea-formaldehyde cellulose presented physical and mechanical results for panels lower than those obtained for MDP panels produced with commercial urea-formaldehyde adhesive (Chapter 4).
247

Síntese e caracterização de adesivos lignina-fenol-formaldeído para madeira e derivados / Synthesis and characterization of lignin-phenol-formaldehyde adhesives for wood and derivatives

Santos, Larissa Carvalho 24 February 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-08-16T17:38:42Z No. of bitstreams: 1 texto completo.pdf: 861565 bytes, checksum: ef1ba3e212f784a17b42d18702a293ed (MD5) / Made available in DSpace on 2017-08-16T17:38:42Z (GMT). No. of bitstreams: 1 texto completo.pdf: 861565 bytes, checksum: ef1ba3e212f784a17b42d18702a293ed (MD5) Previous issue date: 2016-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objetivou-se incluir lignina Kraft na síntese de adesivos fenólicos e avaliar seu efeito sobre as propriedades dos mesmos. A lignina foi fenolada a 15, 30, 45 e 60%, e utilizada para produção de resóis pela substituição do fenol, produzindo-se quatro adesivos lignina-fenol-formaldeído, além da testemunha, sem substituição. Caracterizaram-se os adesivos realizou-se a colagem da madeira para avaliação da resistência na linha de cola, nas condições seca e úmida. Produziram-se MDPs com madeira de Eucalyptus sp. a partir dos tratamentos testemunha e adesivo 3, que mais se assemelhou àquele. Avaliaram-se a UEH, densidade aparente, inchamento e absorção de água após imersão por 2h e 24h, tração perpendicular, MOR e MOE, arrancamento de parafuso e dureza Janka dos painéis, e os resultados foram comparados às normas NBR e ANSI. Verificou-se que a lignina apresentou baixos teores de umidade, carboidratos, cinzas e minerais, e alto percentual de lignina total. Observou-se aumento na viscosidade dos adesivos conforme elevou-se a quantidade de lignina presente. Foram observadas diferenças estatísticas entre o pH dos adesivos, que também foram associadas à adição de lignina, mas em uma relação inversa. O tempo de gelatinização também variou estatisticamente entre os tratamentos, sem relação com o teor de lignina presente; todos os adesivos sintetizados com substituição do fenol apresentaram tempo de gelatinização inferior à testemunha. Todos os tratamentos apresentaram diferenças estatísticas quanto ao teor de sólidos, sendo o maior valor encontrado para o adesivo testemunha. A presença da lignina nos adesivos não prejudicou suas propriedades de adesão e de resistência mecânica, já que a maioria dos adesivos apresentou valores de resistência ao cisalhamento estatisticamente iguais à testemunha. O adesivo 3 foi o que mais se assemelhou ou superou a testemunha. Os valores médios obtidos para UEH, densidade aparente e dureza Janka dos MDPs atenderam às normas, mas somente o tratamento 3 foi satisfatório no teste de arrancamento de parafuso. Painéis confeccionados com o adesivo lignina-fenol-formaldeído incharam menos em relação aos demais. Concluiu-se que a adição de lignina Kraft nos adesivos fenólicos não causou prejuízo às propriedades dos painéis, e lhes conferiu maior resistência à água. / The objective was to include Kraft lignin in the synthesis of phenolic adhesives and to evaluate their effect on the properties of the same. The lignin was phenolated at 15, 30, 45 and 60%, and used for the production of resoles by the substitution of phenol, producing four lignin-phenol-formaldehyde adhesives, besides the control, without substitution. The adhesives were characterized by bonding the wood to evaluate the resistance in the glue line, under dry and wet conditions. MDPs were produced with Eucalyptus sp. From the control and adhesive treatments 3, which most resembled that one. The UEH, apparent density, swelling and water absorption after 2h and 24h immersion, perpendicular traction, MOR and MOE, screw pulling and Janka hardness of the panels were evaluated, and the results were compared to NBR and ANSI standards. It was verified that the lignin had low levels of humidity, carbohydrates, ashes and minerals, and high percentage of total lignin. An increase in the viscosity of the adhesives was observed as the amount of lignin present was increased. Statistical differences were observed between the pH of the adhesives, which were also associated with the addition of lignin, but in an inverse relationship. The gelatinization time also varied statistically among the treatments, unrelated to the lignin content present; All adhesives synthesized with phenol substitution showed gelatinization time lower than the control. All treatments presented statistical differences regarding solids content, being the highest value found for the control adhesive. The presence of lignin in the adhesives did not impair its adhesion and mechanical strength properties, since most of the adhesives presented values of shear strength statistically equal to the control. Adhesive 3 was the one that most resembled or surpassed the control. The mean values obtained for UEH, apparent density and Janka hardness of the MDPs met the standards, but only treatment 3 was satisfactory in the screw tear test. Panels made with the lignin- phenol-formaldehyde adhesive swelled less in relation to the others. It was concluded that the addition of Kraft lignin in the phenolic adhesives did not cause damage to the properties of the panels, and gave them greater resistance to water.
248

Sistema adesivo odontológico com nanocápsulas contendo fármacos / Dental adhesive system containing drugs-loaded nanocapsules

Genari, Bruna January 2016 (has links)
O objetivo da presente tese foi desenvolver um adesivo com nanocápsulas (NCs), contendo indometacina, e um sistema adesivo com nanocápsulas (NC), contendo indometacina e triclosan, e avaliar suas propriedades. As NCs foram produzidas por meio do método de deposição de polímero, secas e caracterizadas quanto ao tamanho de partículas, à forma, quantidade de fármaco encapsulado e citotoxicidade. Uma resina adesiva foi formulada. Foram adicionadas ao adesivo 1%, 2%, 5% e 10% de NCs em massa, e um grupo permaneceu sem NC. As NCs, contendo indometacina e triclosan, foram também incorporadas no primer comercial a 2% em peso e um grupo permaneceu sem NCs. Os adesivos foram avaliados quanto ao GC imediato e tardio, à degradação em solvente, liberação dos fármacos, difusão de indometacina pela dentina e resistência de união. O adesivo com 10% de NCs, contendo indometacina, foi também avaliado quanto à ação anti-inflamatória em modelo animal. O primer e o adesivo com as diferentes concentrações de NCs, contendo indometacina e triclosan, foram avaliados quanto à liberação dos fármacos, difusão de indometacina pela dentina, ao efeito antimicrobiano, grau de conversão (GC) in situ, ângulo de contato e à resistência de união à microtração. Os dados foram analisados por ANOVA, Tukey e teste t. As NCs apresentaram forma esférica e viabilidade celular acima de 80%. As NCs, contendo indometacina, apresentaram diâmetro médio de 165 nm e as NCs, contendo indometacina e triclosan, 159 nm. O adesivo, contendo 10% de NCs com indometacina, apresentou efeito anti-inflamatório. A incorporação de NCs não alterou o GC, que variou de 63,63 ± 1,01% a 70,50 ± 2,08%. A degradação em solvente não foi alterada com 2% de NCs. Tanto os adesivos quanto o primer apresentaram liberação controlada. A indometacina permeou através da dentina. O adesivo e primer também apresentaram efeito antimicrobiano. A incorporação de NCs no primer e no adesivo não influenciou o GC in situ nem a resistência de união imediata, em comparação aos materiais sem NCs. O uso concomitante do primer e adesivo com NCs aumentou o ângulo de contato e diminuiu a resistência de união longitudinal. Conclui-se que o uso do adesivo com a incorporação de NCs tem potencial para proporcionar ações terapêuticas à adesão dentinária. / The aim of the present thesis was to develop an adhesive with nanocapsules (NCs) containing indomethacin and an adhesive system with nanocapsules containing indomethacin and triclosan and to evaluate their properties. NCs were prepared by the interfacial deposition of preformed polymer technique, dried and characterized regarding particle size, encapsulated drug content and cytotoxicity. Adhesive resin was produced. Concentrations of 1%, 2%, 5% and 10% of NCs were added in the adhesive and a group was maintained with no NCs. Indomethacin and triclosan-loaded NCs were also incorporated into a commercial primer in a concentration of 2% and a group was maintained with no NCs. Adhesives were evaluated regarding immediate and late degree of conversion (DC), degradation in solvent, drug release, indomethacin diffusion through dentin and bond strength. The adhesive with 10% of NCs containing indomethacin was also evaluated regarding the anti-inflammatory effect in an animal model. Primer and adhesive with different concentrations of NCs containing indomethacin and triclosan were evaluated regarding drug release, indomethacin diffusion through dentin, antimicrobial effect, in situ degree of conversion, contact angle and bond strength. Data were analyzed through ANOVA, Tukey post-hoc and t-test.NCs presented a spherical shape and cell viability higher than 80%. NCs containing indomethacin presented an averaged size of 165 nm and NCs containing indomethacin and triclosan, 159 nm. The adhesive with 10% of NCs containing indomethacin presented anti-inflammatory effect. The incorporation of NCs presented no alteration of DC, varying from 63.63 ± 1.01% a 70.50 ± 2.08%. Degradation in solvent suffers no influence of NCs with 2% of NCs. Adhesives and primer presented controlled drug release. Indomethacin diffused through dentin. Adhesive and primer also presented an antimicrobial effect. The incorporation of NCs in adhesive and primer showed no influence on in situ DC and immediate bond strength compared to materials with no NCs. The use in combination of primer and adhesive with NCs resulted in higher contact angle and lower longitudinal bond strength. It is possible to conclude that the use adhesive with incorporation of NCs has potential to provide therapeutic effects on dentin adhesion.
249

Comparação da infiltração apical entre canais obturados com guta-percha/AH Plus e o sistema Resilon/Epiphany quando submetidos a duas técnicas de obturação / Comparison of apical leakage between canals filled with gutta-percha/AH Plus and the Resilon/Epiphany System, when submitted to two filling techniques

Veríssimo, Denusa Moreira January 2007 (has links)
VERÍSSIMO, Denusa Moreira. Comparação da infiltração apical entre canais obturados com guta-percha/AH Plus e o sistema Resilon/Epiphany quando submetidos a duas técnicas de obturação. 2007. 109 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2007. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-08T11:54:38Z No. of bitstreams: 1 2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-01T12:43:40Z (GMT) No. of bitstreams: 1 2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) / Made available in DSpace on 2012-02-01T12:43:40Z (GMT). No. of bitstreams: 1 2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) Previous issue date: 2007 / The purpose of this study was to compare the level of apical leakage between canals filled with gutta-percha/AH Plus (GP) and the Resilon/Epiphany System (RES), when submitted to two filling techniques, and to observe, through the use of Optic Microscopy (OM), the adaptation of these materials to the dentinal walls in carried through transversal cuts to 4 mm of the apex. For the evaluation of leakage, seventy extracted human teeth were instrumented and randomly divided into 4 experimental groups in accordance with the material and technique used (lateral condensation and Hybrid technique - HT), and two control groups (positive and negative). After 7 days in an oven (37° C, humidity of 100%), the teeth were immersed in Indian ink and cleared. Leakage was measured by the NIH imageJ program. The exact Fisher test was used to make the comparison between the non-leakage percentages and the non-parametric Mann-Whitney test to measure the leakage when there was any. The value p<0.05 was considered to be statistically significant. With regard to the presence of leakage, there was no difference between the filling techniques (p>0.05), but there was a statistically significant difference when RES was compared with GP (p<0.05), which leaked more than RES. With RES, leakage was confined to the apical third and HT could be used to thermo-plasticize RES with satisfactory results. It was observed through the analysis in OM of 20 remaining teeth, filled in the same way that the experimental groups (5 teeth for each group), that the RES presented many areas mismatch between the material and the dentinal walls, what it would justify occurred leaking with this material. / O propósito deste estudo in vitro foi comparar o nível de infiltração apical entre guta-percha/AH Plus (GP) e Sistema Resilon/Epiphany (SRE) quando submetidos a duas técnicas de obturação, e observar, através do uso de Microscopia Óptica (MO), a adaptação destes materiais às paredes dentinárias em cortes transversais realizados a 4mm do ápice. Para a avaliação da infiltração, 70 raízes de dentes humanos extraídos foram instrumentadas e divididas aleatoriamente em quatro grupos experimentais de acordo com o material e técnica empregados (condensação lateral e técnica Híbrida-TH) e dois grupos controles (positivo e negativo). Após sete dias em estufa (37°C, umidade de 100%), as raízes foram imersas em tinta nanquim (7 dias) e diafanizadas. A infiltração linear foi medida através do programa NIH imageJ. Utilizou-se o teste exato de Fisher, para a comparação entre percentual de não-infiltração e teste não-paramétrico de Mann-Whitney, para testar o comprimento de infiltração, quando esta existiu. O valor de p<0,05 foi considerado ser estatisticamente significante. Na presença de infiltração, não houve diferença entre as técnicas de obturação empregadas (p>0,05), mas houve diferença estatisticamente significante quando o SRE foi comparado à GP (p<0,05), que apresentou maior infiltração. Concluiu-se que a infiltração com o SRE ficou confinada ao terço apical e a TH pode ser utilizada para termoplastificação do SRE com resultados satisfatórios. Observou-se através da análise em MO dos 20 dentes restantes, obturados da mesma forma que os grupos experimentais (cinco dentes para cada grupo), que o SRE apresentou muitas áreas de desadaptação entre o material e as paredes dentinárias, fato que justificaria a infiltração ocorrida com esse material.
250

Influência de cimentos provisórios sobre a resistência de união de restaurações indiretas á dentina utilizando dois sistemas adesivos resinosos / Influence of temporary cements on the bond strength of indirect restorations to dentin employing two resinous adhesive systems

Ribeiro, José Carlos Viana January 2007 (has links)
RIBEIRO, José Carlos Viana. Influência de cimentos provisórios sobre a resistência de união de restaurações indiretas á dentina utilizando dois sistemas adesivos resinosos. 2007. 141 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, 2007 . / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-14T11:47:41Z No. of bitstreams: 1 2007_dis_jcvribeiro.pdf: 22874823 bytes, checksum: 9135768d5a904083e88ca2b921707251 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-01T16:01:45Z (GMT) No. of bitstreams: 1 2007_dis_jcvribeiro.pdf: 22874823 bytes, checksum: 9135768d5a904083e88ca2b921707251 (MD5) / Made available in DSpace on 2012-02-01T16:01:45Z (GMT). No. of bitstreams: 1 2007_dis_jcvribeiro.pdf: 22874823 bytes, checksum: 9135768d5a904083e88ca2b921707251 (MD5) Previous issue date: 2007 / The aim of this in vitro study was to evaluate the influence of residual temporary cements on the microtensile bond strength of indirect composite resin build-ups employing two types of adhesive systems. Thirty non-carious human third molars were selected and the occlusal enamel was removed to produce flat dentin surfaces. The surfaces were coated with provisional restorations fixed with either eugenol-containing temporary cement (Temp Bond), or non-eugenol temporary cement (Freegenol). After one week, the provisional restorations and residual cement were removed with a dental probe and one specimen of each group was selected for evaluation by atomic force microscopy to investigate the presence of remnants of temporary cements. For the control groups, no provisional restorations were made. The dentin surfaces were cleaned with pumice and treated either with a total-etch (TE) adhesive system (Adper Single Bond 2) or with a self-etch (SE) adhesive system (Adper Prompt). Composite resin build-ups (Filtek Z250) were fixed to the bonded dentin surfaces using resin luting cement (RelyX ARC). The bonded specimens were then cross-sectioned producing sticks of 0.9 mm2 of adhesive area. Microtensile bond strength testing was perfomed in a universal test machine at a rate of 0.5 mm/min until fracture occurred. Optical microscopic images and scanning electron micrographs of fractured surfaces were obtained and recorded for fractographic analysis. Bond strength values were submitted to analysis of variance (ANOVA) and t-Student tests to detect significant differences between groups. The results showed a significant reduction on microtensile bond strength values when Temp Bond cement was employed in comparison with the control groups either for TE (p = 0.0331) or SE (p = 0.0267) adhesive systems. Total-etch groups showed significantly higher bond strength values than self-etch groups (p < 0.0001). Optical and scanning electron microscopic analysis revealed a majority of mixed fractures (67%). Adhesive failure at dentin-adhesive interface was significantly higher for SE groups than for TE groups (p = 0.0001). Atomic force microscopic images showed that residues of both temporary cements remained on dentin surfaces even after mechanical cleansing and treatment with acids. Bond strengths of total-etch and self-etch adhesive systems were significantly lowered only when eugenol-containing temporary cement was used prior to bonding and cementation procedures. / O presente estudo experimental in vitro se propôs a investigar a influência de resíduos de cimentos provisórios sobre a resistência de união de restaurações indiretas de resina composta à dentina, empregando-se dois sistemas adesivos resinosos, por meio de ensaio mecânico de microtração. Superfícies planas de dentina foram obtidas a partir da remoção do esmalte oclusal de 30 (trinta) dentes terceiros molares humanos sem lesões de cárie, extraídos por indicação cirúrgica ou ortodôntica. Os espécimes foram distribuídos em 6 (seis) grupos, de acordo com o tipo de cimento provisório e o tipo de sistema adesivo empregado. Discos de resina acrílica foram fixados à superfície dentinária dos espécimes empregando-se o cimento provisório com eugenol Temp Bond ou o cimento sem eugenol Freegenol. Após 7 (sete) dias em água destilada a 37°C, as restaurações provisórias e os resíduos de cimento foram removidos com instrumento manual. Nos grupos-controle, não foram empregadas restaurações provisórias. As superfícies dentinárias foram limpas com pasta de pedra-pomes e água e tratadas de acordo com o sistema adesivo empregado: condicionamento com ácido fosfórico a 37% e aplicação do sistema adesivo Adper Single Bond 2 (SB2) ou aplicação do sistema adesivo autocondicionante Adper Prompt (AP). Em seguida, blocos de resina composta (Filtek Z 250) foram fixados ao substrato dentinário utilizando-se um cimento resinoso (RelyX ARC). Através de cortes seriados, foram obtidos corpos-de-prova em forma de palitos com área de interface adesiva de aproximadamente 0,9 mm2 que foram submetidos ao ensaio de microtração em máquina universal de testes com velocidade de 0,5mm/min até a ruptura. A resistência adesiva foi expressa pela tensão de ruptura dos corpos-de-prova. Os modos de fratura das interfaces adesivas foram analisados por microscopia óptica digital e microscopia eletrônica de varredura. A presença de resíduos dos cimentos provisórios foi investigada por microscopia de força atômica. Os resultados de resistência adesiva foram submetidos à análise de variância (ANOVA) de dois critérios e teste t-Student para detectar diferenças significativas entre os grupos. Observou-se uma redução estatisticamente significativa da resistência adesiva quando o cimento Temp Bond foi empregado em relação aos grupos-controle, tanto com o sistema adesivo SB2 (p = 0,0331) quanto com o sistema AP (p = 0,0267). Os grupos em que o sistema SB2 foi utilizado apresentaram valores de resistência adesiva estatisticamente superiores aos grupos com o sistema AP (p< 0,0001), independentemente do emprego ou não de cimentos provisórios. A análise dos modos de fratura mostrou uma maior ocorrência de fraturas mistas (67%), sendo que nos grupos com o sistema de condicionamento ácido total a ocorrência de fraturas adesivas na interface dentina-adesivo foi estatisticamente menor que nos grupos com o sistema autocondicionante (p = 0,0001). Com base nesses resultados, concluiu-se que resíduos microscópicos dos dois cimentos provisórios permaneceram sobre a superfície dentinária mesmo após limpeza mecânica e tratamento com ácidos. Porém, apenas o cimento provisório contendo eugenol reduziu significativamente a resistência de união à dentina das restaurações indiretas de resina, independentemente do sistema adesivo empregado.

Page generated in 0.0503 seconds