Spelling suggestions: "subject:"adesivos."" "subject:"adhesivos.""
251 |
Avaliação in situ da influência da utilização de diferentes sistemas adesivos no desenvolvimento da cárie secundária em esmalte / In situ evaluation of secondary caries inhibition promoted by self-etch adhesive systems containing antibacterial agentsVasconcelos, Suyane Maria Luna Cruz de January 2008 (has links)
VASCONCELOS, Suyane Maria Luna Cruz de. Avaliação in situ da influência da utilização de diferentes sistemas adesivos no desenvolvimento da cárie secundária em esmalte. 2008. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2008. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-19T12:32:21Z
No. of bitstreams: 1
2008_dis_smlcvasconcelos.pdf: 1627430 bytes, checksum: dc91483ce3821b1b638f3d470fcb3d52 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-02T16:12:23Z (GMT) No. of bitstreams: 1
2008_dis_smlcvasconcelos.pdf: 1627430 bytes, checksum: dc91483ce3821b1b638f3d470fcb3d52 (MD5) / Made available in DSpace on 2012-02-02T16:12:23Z (GMT). No. of bitstreams: 1
2008_dis_smlcvasconcelos.pdf: 1627430 bytes, checksum: dc91483ce3821b1b638f3d470fcb3d52 (MD5)
Previous issue date: 2008 / Contemporary adhesives systems present satisfactory bonding to enamel and dentin. However, replacement of the restorations due to secondary caries formation is still a major problem and of great concern in Dentistry. Thus, this study assessed in situ the effects of adhesive systems containing or not fluoride and/or the antibacterial monomer 12-methacryloyloxydodecylpyridinium bromide (MDPB) on the microbiological composition of dental biofilm and on enamel demineralization. During two phases of 14 days each, ten volunteers wore palatal appliances containing four human enamel slabs, which were extra-orally restored using a resin composite (Z250 3M-ESPE) and one of the following adhesive systems: Adper™ Single Bond 2 (total etch, G1); All-Bond SE™ (self-etch, G2); One-Up Bond F Plus (self-etch containing fluoride G3) and Clearfil Protect Bond (self-etch containing fluoride and MDPB, G4). The volunteers were randomly allocated to treatments, and those who received G1 and G2 in the first phase received G3 and G4 in the second one, and vice versa. The volunteers were asked to drop a 20% sucrose solution onto the slabs eight times per day and to use fluoridated dentifrice 3 times per day. The biofilm formed on the slabs was analyzed with regard to total and mutans streptococci as well as lactobacilli counts. Demineralization was determined on enamel around the restorations by cross-sectional microhardness. The data were analyzed by analysis of variance, ANOVA. No differences were found for microbiological composition or enamel demineralization among the studied adhesive systems. It can be concluded that that fluoride or MDPB addition to adhesives systems presented no effect in controlling caries around resin restorations in this in situ model. / Os sistemas adesivos atuais apresentam resultados satisfatórios no que concerne à adesão ao esmalte e à dentina, entretanto, a maior causa de falhas em restaurações estéticas ainda é a ocorrência de recidiva de cárie ao longo de suas margens. Desta forma, este estudo avaliou a ação de sistemas adesivos com flúor e/ou com um novo monômero, brometo de metacriloiloxidodecilpiridinio (MDPB) na composição microbiológica do biofilme dental e no processo de desmineralização do esmalte adjacente à restauração de resina composta, mediante um delineamento in situ, cruzado e duplo-cego. Durante duas fases de 14 dias, dez voluntários utilizaram dispositivos palatinos, contendo, cada um, quatro blocos de esmalte dental humano, restaurados extra-oralmente com resina composta Z250 e um dos seguintes sistemas adesivos: Adper™ Single Bond 2 (condicionamento total, G1), All-Bond SE™ (autocondicionante, G2), One-Up Bond F Plus (autocondicionante com flúor, G3) e Clearfil Protect Bond (autocondicionante com flúor e MDPB, G4). Os voluntários foram aleatoriamente divididos entre os grupos, sendo que os que receberam os sistemas adesivos referentes aos grupos G1 e G2, na 1ª fase, receberam os tratamentos referentes aos grupos G3 e G4 na 2ª fase e vice-versa. Todos os voluntários foram instruídos a gotejar sobre os blocos, oito vezes por dia, uma solução de sacarose a 20%, simulando um desafio cariogênico, e a utilizar um dentifrício fluoretado padronizado três vezes por dia na higienização dentária. Após o término de cada fase o biofilme formado sobre cada bloco foi coletado e utilizado para a contagem de estreptococos totais, estreptococos mutans e lactobacilos. A perda de mineral foi analisada por meio do teste de microdureza em corte longitudinal do esmalte adjacente à restauração. Aplicou-se a análise de variância, ANOVA, não sendo observada diferença estatisticamente significante para a composição microbiológica ou desmineralização do esmalte entre os adesivos estudados. Concluiu-se que a incorporação de MDPB e/ou flúor nos sistemas adesivos autocondicionantes não foi capaz, nas condições deste estudo, de prevenir a ocorrência da cárie secundária.
|
252 |
Pentóxido de nióbio como carga para materiais de base polimérica para uso odontológicoLeitune, Vicente Castelo Branco January 2012 (has links)
O objetivo desta tese foi caracterizar o pentóxido de nióbio (Nb2O5), produzir materiais compósitos de matriz polimérica de uso odontológico e avalia-los. As partículas de Nb2O5 foram caracterizadas com difração de raios-X, microscopia eletrônica de varredura, granulometria a laser, método de Brunauer–Emmett–Teller e espectroscopia micro-Raman. Um adesivo experimental foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 5, 10 e 20 %, em peso). Este adesivo foi avaliado quanto à radiopacidade, grau e cinética de conversão, microdureza e a sua interface com a dentina. Um cimento endodôntico experimental de cura dual também foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 80, 100 e 120 %, em peso). Este cimento foi avaliado quanto à radiopacidade, escoamento, espessura de película, microdureza e grau de conversão (imediatamente, 7 dias e 14 dias após a fotoativação). A avaliação do Nb2O5 mostrou que as partículas utilizadas apresentavam estrutura monoclínica, com formato irregular, com tamanho médio de 38,16 μm, área de superfície de 3,86 m2/g e estrutura química compatível com pentóxido de nióbio. A radiopacidade e dureza do adesivo aumentaram com a incorporação do Nb2O5 e ele pode ser detectado no interior da interface dentina/adesivo. No cimento endodôntico a incorporação do Nb2O5 também aumentou a radiopacidade e a dureza e reduziu o escoamento apenas no grupo com 120 %. O grau de conversão aumentou até 14 dias após a fotoativação, com exceção do grupo com 80%. Após a caracterização do Nb2O5 e da produção dos materiais experimentais, foi feito o depósito de pedido de patente de invenção. Conclui-se que o pentóxido de nióbio é uma nova e promissora partícula para uso em Odontologia como agente de carga. / The aim of this thesis was to characterize the niobium pentoxide (Nb2O5), to produce resin-based composite for dental applications and evaluate them. Niobium pentoxide was characterised by X-ray diffraction, surface area, particle size, micro-Raman and scanning electron microscopy. An experimental adhesive resin was formulated with 0, 5, 10 and 20 wt% Nb2O5. The formulated adhesive resins were evaluated based on microhardness, degree of conversion, radiopacity and interface (resin/dentin) characterisation by micro-Raman. An experimental dual-cured root canal sealer was produced with a methacrylate-based comonomer blend. Nb2O5 was added at four different concentrations: 0, 80, 100 and 120wt%. Radio-opacity, flow, film thickness, microhardness and degree of conversion (after 1, 7 and 14 days) were evaluated. The particles used in this study presented a monoclinic crystalline phase with typical chemical groups, mean size of 38.16 μm and 3.86 m2/g of surface area. Microhardness and radiopacity increased with higher amounts of Nb2O5, and the particles were able to penetrate into the hybrid layers. Microhardness and radiopacity increased with higher amounts of Nb2O5 in the adhesive resin, and the particles were able to penetrate into the hybrid layers. For the endodontic cement, the radiopacity and microhardness increased with the Nb2O5 addition. The flow was significantly smaller for the 120% group. All groups except those with 80wt% had higher values for degree of conversion after 14 days than immediately after photocuring. After the Nb2O5 characterization and the production of experimental materials, an application for patent was done. Niobium pentoxide is a new and promising filler for dental materials production.
|
253 |
CARACTERIZAÇÃO DO BAMBU LAMINADO COLADO COMO ALTERNATIVA TECNOLÓGICA INDUSTRIALROSA, R. A. 30 July 2013 (has links)
Made available in DSpace on 2016-08-29T15:37:04Z (GMT). No. of bitstreams: 1
tese_6569_Dissertação RafaelAmorimRosa.pdf: 6617832 bytes, checksum: 95bb3a949f513fba00dfdcbb7e6646f3 (MD5)
Previous issue date: 2013-07-30 / ROSA, Rafael Amorim. Caracterização do bambu laminado colado como alternativa tecnológica industrial.2013.Dissertação (Mestrado em Ciências Florestais) Universidade Federal do Espírito Santo, Jerônimo Monteiro - ES, Orientador: Prof. Dr. Juarez Benigno Paes. Coorientadores: Profa. Dra. Graziela Baptista Vidaurre e Prof. Dr. Pedro Gutemberg de Alcântara Segundinho.
Este trabalho teve como objetivosverificar as propriedades tecnológicas dos bambus Dendrocalamus gigateus e Bambusa vulgaris; avaliar as propriedades físicas e mecânicas dos bambus laminados colados (BLC) de acordo com as espécies, os adesivos e os tratamentos preservativos utilizadose; correlacionar tanto o módulo de ruptura MORquanto o módulo de elasticidade MOE dos BLCs obtidos por meio dos métodos não destrutivos com o método destrutivo. Para isto, foram produzidas taliscas com dimensões de 0,5 x 3,0 x 70,0 cm (espessura x largura x comprimento) com os bambus das espécies D. gigateus e B.vulgaris com idade superior a três. Uma parte destas taliscas foi imersa em água e a outra em Timbor, com duração de 15 dias para ambos os tratamentos. Os adesivos utilizados foram à base de emulsão de isocianato polimérico (EPI); melamina ureia formaldeído - MUF; acetato de polivinílico cross PVAc eresorcinol formaldeído - RF. Os métodos não destrutivos utilizados para estimar o módulo de elasticidade dos BLCs foram oStress Wave - SW, vibração longitudinal - vib. long. e vibração transversal - vib. trans. Observou-se que, os BLCs confeccionados com B. vulgaris demonstraram maior instabilidade dimensional que aqueles produzidos com o D. giganteus. Entretanto, os adesivos MUF e RF conferiram maior estabilidade dimensional aos BLCs produzidos com ambas as espécies. Tanto os BLCs de D. giganteus quanto o de B. vulgaris em relação aos dois tratamentos preservativos utilizados, tiveram a menor média de falhas no bambu quando aderidos com EPI e PVA. Para os BLCs produzidos com o bambu gigante, o Stress Wave demonstrou não ser indicado para estimar o módulo de elasticidade para os aderidos com EPI, MUF, PVA e RF. Os métodos de vib. long. e vib. trans. demonstraram boa possibilidade da estimação do MOE para os BLCs de D. giganteus para qualquer adesivo. Para os métodos não destrutivos realizados com os BLCs do bambu vulgar, a técnica do Stress Wave demonstrou ser indicado para os BLCs aderidos com MUF e com PVA. No método de vib. long. os BLCs B. vulgaris aderidos com MUF, PVA e RF tiveram alto erro de estimação. Já o método de vib. trans., proporcionou alto coeficiente de correlação de Pearson (R²), demonstrando ser o mais recomendado. O método de vib. trans. mostrou ser o melhor na estimação do módulo de elasticidade tanto para os BLCs confeccionados com D. giganteus quanto para os de B. vulgaris, proporcionando os menores erros e os maiores R². Em função dos resultados físicos e mecânicos obtidos, pode-se afirmar que os BLCs confeccionados tanto com a espécie de D. giganteus quanto de B. vulgaris podem ser indicados para a produção de móveis.
Palavras chave:Bambu laminado colado, Dendrocalamus giganteus,Bambusa vulgaris, adesivos, métodos não destrutivos, tratamentos preservativos.
|
254 |
Efeito do preaquecimento de sistemas restauradores no desempenho de restaurações em dentes posterioresLima, Luana Machado de January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-06-25T20:55:23Z (GMT). No. of bitstreams: 1
308829.pdf: 770581 bytes, checksum: 8278409b6c8fa7aeb27cac498c1d4855 (MD5) / A presente tese teve como objetivo avaliar se o preaquecimento do sistema adesivo e da resina composta foi capaz de promover melhor performance clínica às restaurações em dentes posteriores. Após aprovação do comitê de ética, participaram desta pesquisa 70 pacientes com necessidades de restaurações: oclusal, ocluso-distal ou mesio-oclusal. Utilizou-se do preaquecimento de dois sistemas adesivos [Single Bond 2 (3M ESPE) e P90 Bond (3M ESPE)] e duas resinas compostas: nanoparticulada matriz orgânica metacrilato Filtek#Z350 (3M ESPE) e micro-híbrida matriz orgânica silorano Filtek#P90 (3M ESPE). Esses materiais foram avaliados por um período de 18 meses. Assim, as cavidades pareadas, no mesmo paciente (n=35), formaram os grupos: 1A-Single Bond 2 (3M ESPE), Filtek# Z350 (3M ESPE), sem preaquecimento, (temperatura ambiente, ±25 °C); 1B- mesmos materiais restauradores com preaquecimento (54 °C); 2A- P90 Primer, P90 Bond com Filtek P90 (3M ESPE) sem preaquecimento, (temperatura ambiente, ±25 °C); 2B - mesmos materiais restauradores com preaquecimento (54 °C). Um aparelho de preaquecimento do adesivo e da resina composta, o (Calset#, AdDent Inc., Danbury, CT, EUA), serviu para o propósito. A sensibilidade pós-operatória foi avaliada pela escala de VAS. Após 24 h, as restaurações foram acabadas e polidas. Dois examinadores independentes as avaliaram, conforme método modificado USPHS em intervalos de: 7 dias após o polimento final, 6 meses, 12 meses e 18 meses. Realizaram-se radiografias periapicais e interproximais durante as reavaliações. Foi utilizado o modelo estatístico de regressão logística simples "Razão de Verossimilhança" com nível de significância de 5 % (p<0,05). Em 7 dias, 6 meses, 12 meses e 18 meses após a confecção inicial das restaurações, todas as 140 restaurações (100%) foram avaliadas. Em nenhuma reavaliação houve diferenças significativas nos critérios examinados. Nem a resina composta nem o preaquecimento influenciaram significativamente o desempenho clínico. Em todos os períodos de avaliação, as restaurações se mostraram aceitáveis em todos os quatro grupos para todos os critérios (entre 91,4% e 100% de escores ALFA). Não houve relato de dor. Não houve recidiva de cárie e nem diferenças na adaptação marginal dos materiais ao exame radiográfico. O preaquecimento dos materiais restauradores (sistema adesivo e resina composta) não influenciou a performance clínica. Ao longo dos 18 meses, os materiais e técnicas empregados apresentaram promissores resultados. / This thesis aimed to evaluate whether the preheating of the adhesive systems and composite resin was able to promote best clinical performance of restorations in posterior teeth. After approval by the Ethics Committee, 70 patients who needed restorations in occlusal, occlusal-distal or mesio-occlusal participated in this research. The preheating of two adhesive systems [Single Bond 2 (3M ESPE) and P90 Bond (3M ESPE)] as well as two composite resins: metacrilato organic matrix nanoparticulate Filtek#Z350 (3M ESPE) and the silorano organic matrix microhybrid Filtek#P90 (3M ESPE). These materials were evaluated for a period of 18 months. Hereafter are the groups with paired cavities in the same patient (n=35): 1A- Single Bond 2 (3M ESPE), Filtek# Z350 (3M ESPE) without preheating (room temperature, ±25 °C); 1B- same restorative materials with preheating (54 °C); 2A- P90 Primer, P90 Bond (3M ESPE) with Filtek P90 (3M ESPE) without preheating (room temperature ±25 °C); 2B- the same restorative materials with preheating (54 °C). An apparatus for preheating of the adhesive and the composite resin, (Calset#, AdDent Inc., Danbury, CT, EUA) was used for the purpose of this thesis. The Post-operative sensitivity was evaluated using the VAS scale. After 24 h, the restorations were finished and polished. Two independent observers rated the restorations according to the USPHS modified method in intervals of: 7 days, 6 months, 12 months and 18 months after the final polishing. Periapical and bitewing radiographs were used during reassessments. The statistic model of simple logistic regression "Likelihood Ratio" with a significance level of 5 % (p<0,05) has been used in this thesis. All 140 restorations (100%) were evaluated in 7 days, 6 months, 12 months and 18 months after the initial production of the restorations. It has been found no significant difference in the examined criteria during the evaluations. Neither the restorative materials nor the preheating significantly influenced clinical performance. In all evaluation periods, the restorations proved to be acceptable in the four groups for all criteria (between the ALFA 91,4% to 100% of scores ALFA). There were no reports of pain. There was no recurrence of caries and no differences in marginal adaptation of materials to the radiographic examination. The preheating of restorative materials (adhesive system and composite resin) did not influence the clinical performance. Over the 18 months, the materials and techniques employed showed had promising results.
|
255 |
Avaliação in vitro da resistência de união de sistemas adesivos à dentina e ao esmalte de dentes decíduosMiranda, Carla January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-15T22:41:41Z (GMT). No. of bitstreams: 1
224768.pdf: 4074084 bytes, checksum: 3cf4ae3db421cf659ba7608e8614c12e (MD5) / Este estudo procurou avaliar a resistência de união ao cisalhamento (RUC) de quatro sistemas adesivos à dentina e ao esmalte decíduos, e verificar, após teste de RUC, o tipo de falha na interface adesiva. Sessenta molares decíduos hígidos extraídos tiveram as coroas cortadas no sentido mésio-distal. Os espécimes foram divididos em dois grupos, dentina e esmalte, e subdivididos em quatro subgrupos, de acordo com o sistema adesivo (n=15): Scotchbond Multi-Purpose (SMP), Single Bond (SB), Clearfil SE Bond (CSB) e Adper Prompt L-Pop (APL). Os valores obtidos foram submetidos à ANOVA e Teste de Tukey (p< 0,05). O tipo de fratura predominante foi do tipo coesiva no adesivo. Em esmalte os sistemas adesivos apresentaram RUC estatisticamente similares entre si. Em dentina a RUC do sistema adesivo Adper Prompt L-Pop foi inferior em relação aos demais sistemas adesivos, que foram similares entre si.
|
256 |
Análise da interface e resistência de união de cimentos endodônticos à dentina radicular após imersão em solução tampão fosfato salinoTedesco, Maybell January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-12-05T21:25:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2012
|
257 |
Avaliação in vitro do efeito da desproteinização da dentina decídua de humanos na união de sistemas adesivosKummer, Thais Regina 05 December 2013 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2009. / Made available in DSpace on 2013-12-05T21:57:35Z (GMT). No. of bitstreams: 1
274234.pdf: 12942816 bytes, checksum: e84b92c40a2fee47e3a549704b61c866 (MD5) / O objetivo deste estudo, in vitro, foi avaliar a resistência de união à microtração e a nanoinfiltração, após desproteinização da dentina decídua humana. Foram utilizadas coroas de molares decíduos hígidos, as quais tiveram a superfície oclusal desgastada com lixas de carbeto de silício, até a completa exposição da superfície dentinária, e para padronização da smear layer. Os espécimes foram distribuídos em seis grupos, de acordo com o tipo de tratamento (condicionamento ácido - CA ou CA + hipoclorito de sódio - NaOCl) e os sistemas adesivos: One Step Plus - Bisco (OSP), Single Bond - 3M ESPE (SB), Prime & Bond 2.1 - Dentsply (PB). Para o procedimento de desproteinização foi utilizado hipoclorito de sódio 10% por 30s. Os sistemas adesivos e a resina (Filtek Z 250 - 3M ESPE) foram aplicados de acordo com as recomendações dos fabricantes e os espécimes armazenados em água destilada (37ºC/24h). As coroas foram seccionadas obtendo-se palitos (0,8mm2), os quais foram imediatamente submetidos ao teste de resistência à microtração (Instron - 0,5mm/min), até fratura dos corpos-de-prova. Os valores obtidos foram analisados por ANOVA e teste de Tukey (p<0,05). Os corpos-de-prova foram levados ao microscópio eletrônico de varredura (MEV), para visualização do tipo de fratura e os dados submetidos ao teste de Kruskal-Wallis (p<0,05).A nanoinfiltração foi avaliada utilizando-se palitos e nitrato de prata amoniacal como marcador químico. A deposição da prata foi visualizada ao MEV e analisada de duas formas: 1. Em porcentagem (%), em três regiões do palito, utilizando-se espectometria por energia dispersa por raio-x (EDS); 2. Atribuição de escores pela avaliação das fotomicrografias obtidas ao MEV. Os dados (%) foram analisados por ANOVA e teste de Tukey (p<0,05) e os escores submetidos aos testes de Kruskal-Wallis e U de Mann-Whitney (p<0,05).Os valores médios obtidos para o teste de microtração sem desproteinização foram [MPa(DP)]: PB - 35,95(6,12); SB - 28,82(6,38); OSP - 24,59(6,10); e após desproteinização: PB - 41,47(6,79); OSP - 31,09(9,16); SB - 25,55(7,23). Os padrões de fratura mais comumente encontrados foram coesiva do adesivo e mista, para todos os grupos. A nanoinfiltração, avaliada por porcentagem, apresentou diferença significante para as variáveis tratamento e adesivo. A desproteinização da dentina condicionada reduziu significativamente a infiltração para o adesivo OSP. Para a variável sistema adesivo, na análise por porcentagem e por escores, o adesivo SB apresentou significativamente maior infiltração pelo nitrato de prata quando comparado ao OSP e PB, que foram similares entre si. Conclui-se que a resistência adesiva não foi influenciada pela remoção do colágeno exposto pelo condicionamento ácido e que a nanoinfiltração não foi evitada pela desproteinização dentinária.
|
258 |
A first approach to structural health monitoring of adhesive bonded joints in pipelines using integrated fiber optic sensorsCabral, Thiago Destri January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2016. / Made available in DSpace on 2017-04-11T04:16:20Z (GMT). No. of bitstreams: 1
344789.pdf: 9160244 bytes, checksum: 908c5a89c601a29ba651dda87d6c88b5 (MD5)
Previous issue date: 2016 / Abstract : The sea, sea salt aerosol, direct exposure to sunlight and corrosive fluids make oil and gas rigs hostile environments for its own infrastructure. Metallic pipelines and structural items are being progressively replaced by engineering plastics and composite materials with high structural efficiency and corrosion resistance. As these components require regular inspection and maintenance routines, developing non-destructive inspection techniques is required. The high cost associated with conducting maintenance in hazardous and difficult to access areas, along with the prevalence of premature failure of adhesive bonded joints between composite material pipes, creates a demand for passive long-term monitoring techniques able to act as a bridge between scheduled inspections. This work explores the use of fiber optic sensors integrated into the bonded joints as a potential long-term solution. Several optical fiber sensors were studied and one was selected for testing purposes. Sensors were then integrated internally and externally to bonded joints between pipes with similar geometry to those used in oil and gas rigs. A series of non-destructive tests plus a destructive test were realized. Shearography and computed tomography, as supporting techniques, corroborate the capacity of the selected sensors and devised sensing strategy to detect the presence of voids and debondings at various stages of the pipeline?s life cycle.<br> / O mar, a atmosfera salina, a incidência solar e a presença de fluidos corrosivos fazem de plataformas de prospecção de petróleo e gás ambientes hostis para a infraestrutura nelas instalada. Tubulações e itens estruturais metálicos vêm sendo substituídos por plásticos de engenharia e materiais compostos com alta eficiência estrutural e resistência à corrosão.Um material compósito é formado pela combinação, em escala macroscópica, de dois ou mais componentes com distintas características físicas e química, que quando combinados produzem um material cujas propriedades diferem das de seus constituintes.Visto que estes componentes também necessitam de inspeção e manutenção regular, tem-se a necessidade de desenvolvimento de múltiplas técnicas não-destrutivas de avaliação. O que levou à adaptação de técnicas como a termografia, holografia, shearografia, ultrassonografia e tomografia para a inspeção de compósitos.Ainda, o alto custo associado à realização de ensaios em áreas classificadas e de difícil acesso, conjuntamente com a prevalência de falhas prematuras em uniões adesivadas em tubulações de material composto, criam uma demanda por técnicas passivas de monitoramento a longo prazo capazes de atuar como uma ponte entre as inspeções periódicas.A união por adesivo é um processo testado, confiável e consolidado para unir substratos metálicos, plásticos, cerâmicos e compósitos. Apresenta como vantagens com relação às uniões parafusadas ou rebitadas massa reduzida, melhor distribuição de esforços mecânicos e melhor resistência à fadiga devido à maior flexibilidade e capacidade de inibição da propagação de trincas dos adesivos. Apesar disso são de difícil modelagem matemática, difícil manutenção e são consideradas como uniões permanentes. Este é o processo mais utilizado para unir tubulações de plástico e de compósito, tanto em aplicações na construção civil como na indústria.O presente trabalho explora a utilização de sensores de fibra óptica integrados às uniões adesivadas como potencial solução deste problema.Foram estudados diversos sensores de fibra óptica, como redes de Bragg, interferômetros de Fabry-Pérot e sensores distribuídos com base em deflectometria. Alguns sensores capazes de medir múltiplos parâmetros também são apresentados.Para a realização de ensaios, sensores de fibra óptica foram integrados interna e externamente a uniões adesivadas de tubulações de características similares às utilizadas em campo. Um total de doze fibras sensoras, contendo 3 redes de Bragg cada foram colocadas internamente à camada de adesivo das uniões para medir o campo de deformação axial no interior da união. Além disso, fibras mais longas contendo 12 redes de Bragg foram projetadas para serem enroladas externamente ao longo da circunferência das uniões.Uma série de ensaios não-destrutivos foram realizados, começando-se por testes de inserção dos sensores. Três uniões adesivadas foram instrumentadas, incluindo uma com defeitos planejados para fins de comparação.Por fim um dos corpos de prova foi ensaiado de maneira não-destrutiva para avaliar se a instrumentação integrada possui impacto negativo nas propriedades mecânicas das uniões. O corpo de prova ensaiado falhou em uma região distante da instrumentada, mas mais testes precisam ser realizados para que se estabeleça significância estatística de que a instrumentação não foi deletéria.Shearografia digital e tomografia computadorizada foram utilizadas como técnicas de apoio e corroboraram a capacidade dos sensores selecionados e da estratégia de medição adotada para a detecção da presença de vazios e falhas de adesão em várias etapas do ciclo de vida das uniões.<br>
|
259 |
Avaliação da resistência de união à tração de cimentos adesivos a uma liga de níquel-cromoAndretti, Fabio Luiz January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-21T02:56:27Z (GMT). No. of bitstreams: 1
200123.pdf: 1541451 bytes, checksum: cc8fa4357e521d76a32300021deaae1b (MD5) / Este estudo avaliou a resistência de união à tração de dois cimentos resinosos de dupla ativação (RelyX CRA e Bistite II DC) e dois cimentos de ionômero de vidro para fixação (Ketac Cem Radiopaque e Vivaglass Cem PL) a uma liga metálica de Ni-Cr, aos 15 min e 24 h de armazenamento após o tempo de presa. O cimento resinoso Bistite II DC apresentou diferença significativa em relação aos demais cimentos, tanto aos 15 minutos como após 24 horas. Os grupos de cimentos resinosos de 24 h não apresentaram diferença estatística em relação aos grupos de 15 min e os grupos de cimentos de ionômero de vidro de 24 h foram superiores aos grupos de 15 min.
|
260 |
Microinfiltração marginal em restaurações adesivas diretas e indiretas em dentes posterioresBecker, Mirian Marly January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T16:09:56Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:51:07Z : No. of bitstreams: 1
181792.pdf: 3275309 bytes, checksum: 471976201d80b19e357aa8f4be3e1102 (MD5) / Através deste estudo, avaliou-se in vitro a microinfiltração marginal de restaurações posteriores em resina composta. Quarenta dentes humanos hígidos, mantidos em água a temperatura ambiente após a exodontia foram divididos aleatoriamente em quatro grupos: Grupo A - restaurações diretas com término da parede gengival 1mm aquém da junção amelo-cementária; Grupo B - restaurações diretas com término da parede gengival em nível da junção amelo-cementária; Grupo C - restaurações indiretas realizadas em consultório, sobre troquel de poliéter e parede gengival em nível de junção amelo-cementária; Grupo D - restaurações indiretas em troquel de gesso e parede gengival em nível da junção amelo-cementária. Todos os dentes receberam um preparo tipo MOD, com forma e tamanho padronizados. As restaurações foram confeccionadas em resina composta posterior FiltekP60 (3M) e ArtGlass (Kulzer). As restaurações indiretas foram cimentadas com Cimento de Resina Estético - Calibra (DENTSPLY - Caulk - Espanha). Após restaurados os dentes foram hidratados, termociclados, impermeabilizados, corados e seccionados. A microinfiltração marginal foi avaliada através de fotografias com um aumento de 3X. Os resultados mostraram que houve diferença estatisticamente significante entre as restaurações diretas do grupo B quando comparadas com as restaurações indiretas do grupo D, as quais apresentaram microinfiltração significativamente menor. Não havendo diferença estatisticamente significante quanto a microinfiltração entre os demais grupos. Além disso, todas as configurações cavitárias, técnicas e materiais restauradores utilizados, apresentaram algum grau de microinfiltração marginal.
|
Page generated in 0.0356 seconds