• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1430
  • 1253
  • 58
  • 41
  • 38
  • 25
  • 24
  • 23
  • 20
  • 17
  • 13
  • 5
  • 3
  • 3
  • 2
  • Tagged with
  • 2872
  • 509
  • 433
  • 405
  • 338
  • 338
  • 338
  • 338
  • 338
  • 301
  • 296
  • 290
  • 287
  • 286
  • 258
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Integração de dados geológicos para prospecção de aqüíferos fraturados em trecho da bacia hidrográfica Taquari-Antas (RS)

Reginato, Pedro Antonio Roehe January 2003 (has links)
A presente tese de doutoramento tem por objetivo determinar os condicionantes geológicos do sistema aqüífero fraturado e a caracterização desse sistema, por meio da integração de dados em ambientes de Sistemas de Informações Georreferenciadas (SIGs). Além disso, busca introduzir uma nova perspectiva de levantamento, tratamento e análise de dados de estruturas deformacionais (zonas de fratura) aplicada à prospecção de aqüíferos fraturados. A área de estudo localiza-se em parte da bacia hidrográfica Taquari-Antas, na região nordeste do Estado do Rio Grande do Sul. O sistema aqüífero fraturado da região de estudo está hospedado em rochas vulcânicas da Fm. Serra Geral (Bacia do Paraná) e é aproveitado para abastecimento público e para o desenvolvimento de atividades industriais, agrícolas e recreativas. O sistema aqüífero fraturado consiste num sistema descontínuo, heterogêneo e anisotrópico, caracterizado pela ocorrência de vazões variáveis (72,1% dos poços tubulares apresentam vazões abaixo de 10 m3/h), transmissividade e capacidades específicas baixas. As características hidrogeoquímicas das águas subterrâneas desse sistema aqüífero estão condicionadas pela litogeoquímica das rochas percoladas e secundariamente por controles tectônicos e morfoestruturais responsáveis pela comunicação entre diferentes sistemas aqüíferos e a conseqüente mistura das águas subterrâneas. O padrão de estruturas deformacionais (zonas de fratura) é o condicionante de maior importância. Esse padrão foi caracterizado por meio de lineamentos tipo 2, representados por fraturas, zonas de fraturas, veios e diques. Esse padrão resultou da atuação de dois campos paleotensionais distintos que apresentam orientação ortogonal entre si. Dessa forma, diferentes sub-regiões apresentam comportamentos distintos com relação ao padrão estrutural existente. Os fatores relevo, solos e litologia são condicionadores secundários do sistema aqüífero fraturado. As relações apresentadas por esses fatores com o sistema aqüífero fraturado estão associadas ao grau de dissecação do relevo, à declividade, aos tipos e espessuras de solos, bem como, aos tipos litológicos e estruturas primárias associadas. A integração de dados envolveu o cruzamento dos diferentes condicionantes geológicos por meio de rotinas de tabulação cruzada, medidas de classes e técnicas de suporte à decisão disponíveis no programa SPRING. Com essa integração, foram obtidos mapas de favorabilidade à ocorrência de aqüíferos fraturados. As áreas que apresentam lineamentos associados a relevos com baixo grau de dissecação, baixas declividades (inferiores a 30%), solos de espessura média a alta do tipo Podzólico, Cambissolo e Litossolos, possuem as maiores correlações com poços tubulares produtivos. Com relação aos lineamentos, foi verificado que i) os lineamentos noroeste de orientações N30 – 40W e N50 – 60W estão associadas as maiores vazões (acima de 20 m3/h); ii) os lineamentos nordeste de orientações N20 - 30E e N40 - 50E também estão associados a vazões acima de 20 m3/h; iii) os lineamentos norte-sul de maiores vazões estão na orientação N00 – 14E; e iv) os lineamentos leste-oeste de maior produção estão orientados segundo N80 – 90W. A análise dos condicionantes geológicos e dos produtos obtidos pela integração de dados mostra que as diferentes regiões que formam a área de estudo apresentam comportamentos diferenciados. Dessa forma, o modelo prospectivo proposto para a área de estudo pode ser dividido em duas etapas: i) levantamento estrutural da região e ii) caracterização dos condicionantes secundários. Com o desenvolvimento dessas duas etapas, há uma maior tendência da obtenção de poços tubulares produtivos. / The present doctoring thesis aims to determine the geologic contingents from the fractured aquiferous system and its characterization, through data integration in environments of Georelated Information Systems (GIS). Furthermore, wants to introduce a new survey perspective, treatment and analysis of deformed structures (fractured zones) applied to fractured aquiferous prospection. The area of study is located in the Taquari – Antas hydrographic basin, in the Northeast region of the state of Rio Grande do Sul. The fractured aquiferous system of the area of study is hosted on volcanic rocks from Fm. Serra Geral (Paraná Basin) and it has been currently used for public provision and for recreational, agricultural and industrial activities development. The fractured aquiferous system consists of a discontinuous, heterogeneous and anisotropic system characterized by the occurence of varied outflows (72,1% of tubular wells present outflows below 10 m3/h), transmissivity and specific capabilities. The hydrogeochemical characteristics of underground waters of this aquiferous system have been conditioned by the lithogeochemistry of percolated rocks and secondly by tectonic and morphstructural controls responsible for the communication between different aquiferous systems and the consequent mixture of underground waters. The pattern of deforming structures (fractured zones) is the most important contingent. Such pattern has been characterized through lineaments type 2, represented by fractures, fracture zones, veins and dikes. This pattern has resulted from the action of two distinct paleontologic fields that present orthogonal orientation between them. Thus, different subregions present distinct behaviours in relation to the current structural pattern. Relief factors, soils and lithology are secundary contingents from the fractured aquiferous system. The connections presented by these factors to the fractured aquiferous system have been associated to the degree of relief dissecation, to declivity, to soil types and density, as well as to lithologic types and associated primary structures. Data integration have entwined the hybridization/ crossing of different geologic contingents through the practice of mixed tabulation, class measurements and support techniques to the decision available on SPRING program. Along with this integration propitiatory maps to the occurence of fractured aquiferous have been obtained. Areas that present associated lineaments to reliefs with low degree of dissecation, low declivity (inferior to 30%), average to high density soils Podzolic, Cambissoil and Lithosoil types, hold the strongest correlation to productive tubular wells. In relation to lineaments it has been ascertained that i) northwest lineaments orientation N30 - 40W and N50 - 60W are associated to larger outflows (above 20 m3/h); ii) northeast lineaments orientation N20 - 30E and N40 - 50E are also associated to outflows above 20 m3/h; iii) north-south lineaments with major outflows are located in orientation N00 – 14E; and iv) east-west lineaments with major production are orientated according to N80 – 90W. The geologic contingents and products obtained by data integration analysis shows that the different regions that form the area of study present distinguished behaviours. Thus, the proposed prospective model to the area of study may be divided into two stages: i) structural survey of the region and ii) characterization of the secondary contingents. By developing those two stages there is a greater tendency to obtaining productive tubular wells.
242

Hidrogeoquímica do sistema aqüífero granular cenozóico do município de Porto Alegre, RS

Ramage, Larissa January 2005 (has links)
As águas subterrâneas são significantemente afetadas pelo ambiente deposicional no Sistema Aqüífero Granular Cenozóico. Os sedimentos terciários e quaternários da Planície Costeira do Rio Grande do Sul que ocorrem em Porto Alegre foram depositados em Sistemas de Laguna/Barreira que geraram depósitos de leques aluviais, fluviais, lacustres e deltáicos. O Sistema Aqüífero Granular Cenozóico na área estudada sofreu influência de transgressões e regressões marinhas iniciadas há 400 mil anos. No presente estudo foram analisadas 39 amostras de água subterrânea na região de Porto Alegre, que se destacam por possuir alto conteúdo de íons, em particular: cloreto (13 a 1680 mg/L), sulfato (4 a 500 mg/L), cálcio (0,9 a 125 mg/L), magnésio (0,7 a 154 mg/L) e sódio (17 a 740 mg/L), permitindo classificá-las como cloretada-cálcico-sódicas com elevados teores de sulfato. Os resultados físico-químicos foram tratados estatisticamente (análise fatorial e análise discriminante), o que permitiu identificar 4 grupos de águas, a partir dos parâmetros de maior correlação, que compreendem cloreto, potássio, cálcio, magnésio, sulfato, sódio, dureza e condutividade elétrica. A dissolução de sais de ambiente marinho ou mixohalino associada com condições hidrodinâmicas de fluxos de baixa velocidade e elevado tempo de residência, são fatores decisivos para a existência dos vários tipos hidroquímicos. O modelamento geoquímico indicou subsaturação em fluorita, halita e gipsita, enquanto calcita e dolomita tendem a saturação. Por outro lado, os cálculos indicam supersaturação em fluorapatita, gibsita, caolinita e goetita.
243

Relação da densidade populacional sobre variáveis de qualidade físico-química das águas superficiais em microbacias hidrográficas urbanas sem cobertura sanitária em Porto Alegre - RS

Bollmann, Harry Alberto January 2003 (has links)
O objetivo principal deste trabalho foi a análise da variação de alguns parâmetros físico-químicos da qualidade das águas de pequenos rios urbanos com baixas a médias densidades de ocupação populacional nas áreas de drenagem de suas bacias hidrográficas. Para isso, foram selecionadas 4 bacias hidrográficas urbanas situadas na Região Metropolitana de Porto Alegre/RS: Arroios Mãe d‘Água e Moinho apresentando média densidade populacional bruta (cerca de 70 hab/ha), Arroio Capivara apresentando baixa densidade populacional (8 hab/ha próximo às nascentes da bacia e 33 hab/ha considerando a área até próximo à sua foz), e o Arroio Agronomia que apresenta um tributário relativamente bem preservado, com ocupação urbana residual (<2 hab/ha), considerado como referencia regional para a qualidade físico-química das águas. Os resultados mostraram que a população residente nestas áreas apresenta deficiências de atendimento do ponto de vista do saneamento básico (coleta e tratamento de esgotos sanitários, coleta de lixo e abastecimento de água) impondo aos moradores o uso de tecnologias de disposição local dos seus resíduos. Como resultado, os dados mostraram uma relação direta entre a densidade populacional e a presença de esgotos não tratados nos corpos d’água, e como conseqüência, observaram-se alterações importantes em quase todas as variáveis físico-químicas escolhidas para o monitoramento da qualidade das águas, quando comparadas com a condição referencial. Entre os modelos de regressão testados (linear, potência, logarítmico, exponencial e polinomial de segundo e terceiro graus) o modelo logarítmico apresentou melhor ajuste sobre os demais, indicando a possibilidade do seu uso para 21 das 26 variáveis.A forma logarítmica indica que, a partir de uma condição natural não urbanizada, mesmo pequenas densidades populacionais são capazes de alterar significativamente a qualidade das águas.
244

Métodos geostatísticos para a incorporação da topografia como informação secundária no mapeamento do nível de água subterrânea

Morales Boezio, Maria Noel January 2004 (has links)
Resumo não disponível.
245

Avaliação das interações de um derivado de tanino em processos com membranas poliméricas de microfiltração e de ultrafiltração

Bertotto, Renata de Carvalho Teles January 2015 (has links)
O uso de sulfato de alumínio como coagulante no tratamento convencional de água é uma prática comum. No entanto, diversos estudos recentes vêm mostrando que o alumínio residual, presente na água tratada, pode estar diretamente ligado ao mal de Alzheimer. Uma alternativa para substituir o alumínio no tratamento de águas é a utilização de coagulantes naturais, biodegradáveis e atóxicos, como por exemplo, quitosana, Moringa oleifera e os produtos derivados de taninos. Simultaneamente, existe a busca por tecnologias mais eficientes para auxiliar o tratamento de água, entre estas tecnologias destacam-se os processos de separação com membranas, mais especificamente a microfiltração (MF) e a ultrafiltração (UF). Neste contexto, o presente trabalho tem como objetivo avaliar a interação de um derivado de tanino com membranas de MF e UF de diferentes materiais - polietersulfona (PES), fluoreto de polivinilideno (PVDF) e acetato de celulose (CA) - e de diferentes massas molares de corte ou tamanho de poro nominal (0,2 μm, 20 kDa, 100 kDa), utilizando técnicas de caracterização de membranas e testes de permeação. A pressão de operação para a filtração de 4 horas com a solução de Acquapol C1 – 550 ppm, foi de 0,5 bar para as membranas de MF (AC-0,2, PVDF-0,2) e 2 bar para as membranas de UF (AC-20, PES-100, PES-20, PVDF-100), ambas as pressões abaixo da pressão crítica. As membranas foram caracterizadas quanto à morfologia utilizando microscopia eletrônica de varredura, à estrutura química por espectroscopia de infravermelho por transformada de Fourier com amostragem por refletância total atenuada, ao caráter hidrofílico através de medidas de ângulo de contato, à permeância hidráulica e ao desempenho na filtração da solução. As membranas de MF apresentaram estrutura mais porosa e maior permeância hidráulica, enquanto as membranas de UF apresentaram estrutura menos porosa e menor permeância hidráulica. Quanto ao caráter hidrofílico, foi possível verificar que a membrana AC-20 é a mais hidrofílica com um ângulo médio de 62º ±2,2, seguido das membranas AC-0,2, PES-100, PES-20, PVDF-100 e PVDF-0,2 com ângulos médios de 73,4º ±4,6, 77º ±0,8, 78,3º ±0,9, 80,1º ±2,8 e 95,2º ±1,5. No teste de filtração, após 4 horas, o fluxo permeado final médio decresceu na seguinte ordem: PVDF-0,2 - AC-20 > PES-100 > PES-20 - PVDF-100 - AC-0,2. O percentual de fouling decresceu na seguinte ordem: PVDF-0,2 > (AC-0,2 > PES-20 - AC-20 - PES-100) > PVDF-100, sendo a membrana PVDF-100 a que apresentou menor percentual de fouling. Os resultados obtidos neste trabalho comprovaram que os fenômenos de incrustação nas membranas de MF e UF são influenciados tanto pelo tipo de material e massa molar de corte ou tamanho de poro nominal, quanto pelas características das membranas. / The use of aluminum sulfate as a coagulant in the conventional water treatment is a common practice. However, several recent studies have shown that the residual aluminum present in the treated water can be directly linked to Alzheimer's disease. An alternative to replace aluminum in the water treatment is the use of coagulants natural, biodegradable and non-toxic, for example, chitosan, Moringa oleifera and tannin derivatives. Simultaneously, there is a search for more efficient technologies to support water treatment, among these technologies stand out membrane separation processes, more specifically microfiltration (MF) and ultrafiltration (UF). In this context, this study aims to evaluate the interaction of a tannin derivative with MF membranes and UF of different materials - polyethersulfone (PES), poly(vinylidene fluoride) (PVDF), cellulose acetate (CA) - and different molar mass cut-off or nominal pore size (0.2 μm, 20 kDa, 100 kDa) using techniques and characterization of membrane permeation test. The operating pressure for 4 hours filtration with Acquapol C1 solution - 550 ppm, was 0.5 bar for the MF membranes (AC-0.2, PVDF-0,2) and 2 bar for the membranes UF (AC-20, PES-100, PES-20, PVDF-100), both pressures below the critical pressure. The membranes were characterized for morphology using scanning electronic microscope, the chemical structure by analyzed by attenuated total reflectance Fourier transform infrared, the hydrophilic character through contact angle measurements, hydraulic Permeation and performance in filtration of the solution. MF membranes had more porous structure and permeance higher hydraulic while UF membranes showed less porous structure and lower hydraulic permeance. Regarding the hydrophilic character, it was verified that the AC-20 is the most hydrophilic membrane with an average angle of 62 ° ± 2.2, followed by AC-0.2 membranes, ESP-100, ESP-20, PVDF-100 and PVDF-0.2 with average angle of 73.4º ±4.6, 77º ±0.8, 78.3º ±0.9, 80.1º ±2.8 e 95.2º ±1.5. The filtration test after 4 hours, the final average permeate flux decreased in this order: (PVDF-0.2 - AC-20) > PES-100 > (PES-20 - PVDF-100 - AC-0,2). The percentage of fouling decreased in the following order: PVDF-0.2 > (AC-0.2 > PES-20 - AC-20 - PES-100) > PVDF-100, with the PVDF-100 membrane presented the lowest percentage of fouling. The results of this study showed that the phenomena of fouling in the MF and UF membranes are influenced both by the type of material and molar cutting mass or nominal pore size, as the characteristics of the membranes.
246

Desidratação de lodos de estação de tratamento de água

Ferranti, Eliana M. January 2005 (has links)
As estações de tratamento de água (ETAs), que utilizam sulfato de alumínio férrico e possuem sistema de extinção para a cal, geram dois principais resíduos: o lodo de ETA, retido nos decantadores durante a etapa de clarificação da água, constituído principalmente por hidróxidos de alumínio, argilas, siltes, areia fina, material húmico e microrganismos e o resíduo de cal, impureza insolúvel removida do processo de extinção da cal virgem, constituído principalmente de carbonato e hidróxido de cálcio. A pesquisa realizada no Instituto de Pesquisas Hidráulicas da UFRGS, em conjunto com o Departamento Municipal de Água e Esgotos (DMAE), avaliou se a adição de resíduo de cal ao lodo de ETA acelera o desaguamento do mesmo. Paralelamente, também foi avaliada a eficiência de uma modificação estrutural nos leitos de secagem convencionais, utilizando-se tijolos cerâmicos na base do mesmo, com o objetivo de avaliar se a capilaridade dos tijolos auxilia o desaguamento do lodo. Uma vez que a quantidade de água presente no lodo da ETA diminua, a utilização deste resíduo na indústria talvez seja economicamente viável. No primeiro experimento foram montados 12 (doze) leitos de secagem, seis convencionais e seis modificados. Foi analisado o teor de umidade nos leitos em função do tempo, bem como monitorado o teor de umidade relativa do ar O segundo experimento foi realizado em escala de bancada, utilizando-se 18 (dezoito) leitos de secagem forrados internamente com manta geotêxtil do tipo bidim (OP-20). Os leitos possuíam um dreno de fundo, para captura do líquido percolado. O experimento foi conduzido em triplicata, nas proporções de 0,0%; 2,5%, 5,0%, 7,5%, 10,0% e 100,0% em peso de resíduo de cal. Foi monitorado o volume de percolado em função do tempo para cada leito. Também foi analisado o pH e a umidade inicial e final dos leitos, bem como o pH e a turbidez do líquido percolado. No resíduo sólido remanescente nos leitos de secagem foi realizada análise de fluorescência de RX. No experimento de modificação estrutural da base dos leitos com uso de tijolos, não foi observada nenhuma melhora no desaguamento do lodo. Acredita-se que os poros capilares dos tijolos saturaram no início do experimento, perdendo seu poder de sucção. No segundo experimento, foi observada uma melhora muito significativa em relação ao volume de líquido percolado em função do tempo, comprovando que a adição de resíduo de cal ao lodo favoreceu a rápida desidratação do mesmo (chegando a ser 40 vezes maior) A relação ótima foi verificada nos leitos que continham 5,0 % em massa de resíduo de cal. Todos os leitos que sofreram a adição de resíduo de cal aumentaram bruscamente o pH e solubilizaram o íon alumínio; porém aprisionaram os íons ferro e magnésio. Tanto a análise de fluorescência de raio X do lodo puro, bem como da mistura com resíduo de cal, remanescentes nos leitos de secagem, identificaram a presença de óxidos de cálcio, alumínio, ferro e sílica. Isso indica que estes resíduos (lodo ou lodo mais cal) podem ser incorporado à matéria-prima do cimento. Ter-se-ia, desta forma, um destino ecologicamente correto para os lodos de ETAs, que deixaria de ser lançado em corpos d’água. A incorporação do lodo de ETA ao cimento traria como principal vantagem o aumento da vida útil das jazidas de argila e de calcáreo, reduzindo a destruição da paisagem, flora e fauna.
247

Secagem e defumação de file de peixe de agua doce Tambacu (Colossoma macropum e Colossoma mitrei)

Rodrigues, Antonio Manoel da Cruz 29 March 1996 (has links)
Orientador: Satoshi Tobinaga / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-21T05:13:45Z (GMT). No. of bitstreams: 1 Rodrigues_AntonioManoeldaCruz_M.pdf: 2647201 bytes, checksum: 2a975e021fda4eacd9be1d134c9d45bd (MD5) Previous issue date: 1996 / Resumo: A secagem de alimentos em ambientes sob condições de temperatura, pressão e umidade controladas, tem sido um procedimento bastante conveniente na determinação de parâmetros físicos e na avaliação das condições de operação do processo. Neste contexto fez-se aqui, um estudo experimental seguido de um tratamento matemático, da secagem de filés de Tambacu (híbrido de: Colossoma macropum e Colossoma mitrei), em forma de lâminas retangulares, previamente salgados e defumados a líquido com extrato vegetal de nogueira. Para tanto, utilizou-se um secador de prato hermeticamente fechado, à pressão atmosférica, dotado de um leito fixo de sílica-gel para manter a umidade do ar constante. O trabalho visou investigar o processo de secagem, tendo como base o modelo de difusão de Fick considerando a difusividade efetiva constante. A temperatura de bulbo seco no interior do secador foi de 27,5 +- 1 °C e a de bulbo úmido de 18,3 +- 1,5 °C. O ar nestas condições, é soprado com uma velocidade de 1,5 m/s sobre a amostra colocada em um prato de alumínio. Os resultados alcançados demonstram a conveniência da metodologia empregada na determinação de parâmetros difusionais em processos de secagem de peixe gorduroso à baixa temperatura / Abstract: Drying of foodstuff under controlled conditions of temperature, pressure and moisture has been a usefull procedure to determine physical parameters and process conditions. Using this technique an experimental study with the aid of a mathematical analysis, was conducted on drying Tambacu (Colossoma mitrei and Colossoma macropum). These lumps were rectangular cuts from the fish fillets and salted and liquid smoked with hickory extract. Dryer was a closed circuit system under atmospheric pressure with a silica¬ gel fixed bed used to control air moisture. Drying mass transfer was analysed through Ficks law (constant diffusivity). Temperature conditions inside the system were kept at 27,5°C for dry bulb and 18,3°C for wet bulb. Air was blown towards a try containning one fish lumps ata average speed of 1,5 m/s Results proved this tobe a good technique to determine diffusional parameters in drying of fatty fish at low temperatures / Mestrado / Mestre em Engenharia de Alimentos
248

Biodegradación de alquilbenceno sulfonato lineal por un consorcio microbiano aislado del río Rímac y su estuario

Manrique Guzmán, Yessenia Cristhel January 2016 (has links)
Verifica la presencia de consorcios microbianos en el río Rímac, así como su aislamiento y caracterización, y cuantifica su capacidad degradativa sobre los detergentes del tipo alquilbenceno sulfonato lineal (LAS). / Tesis
249

Aplicación del modelo ISC-AERMOD para la estimación de dispersión de olores : caso estudio planta de tratamiento de aguas servidas La Farfana

Barrera Curihuentro, Maritza Carolina January 2010 (has links)
Memoria para optar al Título Profesional de Ingeniero en Recursos Naturales Renovables / El funcionamiento de las Plantas de Tratamiento de Aguas Servidas (PTAS) provoca la emisión a la atmósfera de gases odorantes, que podrían afectar a las comunidades vecinas a éstas. Por ello, en el presente estudio se aplicó el modelo gaussiano de dispersión atmosférica ISC AERMOD para la simulación de olores, en base a las unidades de olor europeas definidas en la Norma Europea EN 13725:2003, a fin de evaluar eventos de olores en comunidades cercanas a la Planta de Tratamiento de Aguas Servidas La Farfana. Se trabajó con datos meteorológicos como dirección y velocidad de vientos, radiación global, temperatura, humedad relativa, precipitación, presión atmosférica, cobertura y altura de nubes. Además, de características topográficas representado por un Modelo Digital de Elevación de la zona y las características de las fuentes. En tanto, la cuantificación de las tasas emisiones de olor de las fuentes fue estimada a través de la técnica de olfatometría dinámica. Los resultados del modelo fueron comparados con mediciones en terreno de tipo sensorial (paneles de olor y monitoreo continuo). Estas simulaciones concordaron con ambas mediciones en terreno, generando mapas de olores entre las concentraciones de olores y los principales puntos receptores. Del mismo modo, la modelación se comparó con normativa internacional de países como Holanda, Alemania, Bélgica, España, entre otros; debido a la ausencia de normativa en Chile. Finalmente, se concluyó que la medición de emisiones de olor a través de olfatometría dinámica y el posterior uso de modelos de dispersión para la medición de la concentración del olor son herramientas eficaces para la realización de un estudio de olores en una zona en particular. / Wastewater treatment plants (PTWW) emit to the atmosphere, odorant gases that could affect the communities near them. This study was carried out to see how wastewater treatment plants affect the communities applying the Gaussian atmospheric dispersion modelling ISC AEROMOD for odour simulation, based on European odour units defined in the European norm EN 13725:2003 to evaluate odour situations in the communities near La Farfana wastewater treatment plant. The data considered for this study case was: meteorological weather such as wind speed and wind direction, global radiation, temperature, relative humidity, precipitation, atmospheric pressure, cloud cover and cloud height. Besides topographic characteristics represented by the Digital Elevation Model of the area and the characteristics of the sources. On the other hand, the quantification of the odour emission sources was calculated through the dynamic olfactometry technique. The results of the model were compared with measurements of sensorial type in the field (odour panels and continuous monitoring). These simulations agreed with both measurements in field, generating odour maps between odour concentration and the main receptive points. In the same way, the model was compared with the international norm in countries like Holland, Germany, Belgium, and Spain among others due to the lack of an odour norm in Chile. Finally, it was concluded that the measurement of odour emission through the dynamic olfactometry technique and later use of dispersion models to measure the concentration of odour are effective tools to carry out a research on odour in a particular area.
250

Validación secundaria de una metodología para el análisis microbiológico del agua purificada en una industria farmacéutica

Montero Novoa, Estefanía Aurora January 2015 (has links)
Unidad de práctica para optar al título de Químico Farmacéutico / Autor no autoriza el acceso a texto completo de su documento / El presente trabajo se llevó a cabo en el área de microbiología del departamento de control de calidad del Laboratorio Farmacéutico MINTLAB Co. S.A. Su objetivo fue el desarrollo de la validación secundaria de una metodología para análisis microbiológico del agua purificada. El trabajo se efectuó basándose en las técnicas analíticas recomendadas por la United States Pharmacopea (USP). Previo a la validación se realizó una promoción de crecimiento para así comprobar la idoneidad de los medios de cultivos utilizados. Para el desarrollo de la validación secundaria se trabajó con agua purificada desde el punto de muestreo del área de lavado de control de calidad. Se utilizaron microorganismos de cepas estándares sugeridos en la USP 37. Para ensayos cualitativos (ausencia/ presencia) y cuantitativos para aerobios mesófilos se trabajó con: Escherichia coli, Pseudomona aeruginosa, Staphylococcus aureus y Salmonella typhimurium. Para ensayos cuantitativos para Hongos y levadura: Candida albicans. Se determinaron parámetros cuantitativos para cada uno de los microorganismos de interés, obteniendo como resultados porcentajes de recuperación mayores o iguales al 70 % y coeficientes de variación: menor al 15 % para 30-300 u.f.c/mL, menor al 25 % para 10-30 u.c.f/mL y menor al 35% para menos de 10 u.f.c/mL, dando cumplimiento con los criterios establecidos en la USP. Por lo tanto se pudo establecer que la validación secundaria de la metodología para el análisis microbiológico del agua purificada fue exacta y precisa

Page generated in 0.0395 seconds