Spelling suggestions: "subject:"iir quality."" "subject:"rair quality.""
511 |
Estudo das concentrações de óxidos de nitrogênio em área urbana do município de Manaus por analisadores automáticosCoelho, Ilsa Maria Honório de Valois 05 October 2012 (has links)
Submitted by Lúcia Brandão (lucia.elaine@live.com) on 2015-07-15T17:30:28Z
No. of bitstreams: 1
Tese - Ilsa Maria Honório de Valois Coelho.pdf: 2443935 bytes, checksum: c16d835d602a5d9906c0038a9cd0dd64 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-20T17:53:25Z (GMT) No. of bitstreams: 1
Tese - Ilsa Maria Honório de Valois Coelho.pdf: 2443935 bytes, checksum: c16d835d602a5d9906c0038a9cd0dd64 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-20T17:57:14Z (GMT) No. of bitstreams: 1
Tese - Ilsa Maria Honório de Valois Coelho.pdf: 2443935 bytes, checksum: c16d835d602a5d9906c0038a9cd0dd64 (MD5) / Made available in DSpace on 2015-07-20T17:57:14Z (GMT). No. of bitstreams: 1
Tese - Ilsa Maria Honório de Valois Coelho.pdf: 2443935 bytes, checksum: c16d835d602a5d9906c0038a9cd0dd64 (MD5)
Previous issue date: 2012-10-05 / CNPq - Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico / This work makes a NOx concentrations study in the urban atmosphere of Manaus city,
focusing on the specific meteorological influences of the equatorial region. Initially, we make
a historical contextualization about atmospheric pollution and fuel oil consumption, making
the relation between pollution, city and urban population development. The importance that
chemical knowledge has been in this process is pointed out, enphasizing the Chemical Science
as the basis for all the human development. The difficulties of energy supply whose origins
come from the beginnings of Amazon development, the vehicle fleet increasing and Manaus
city atypical growth, are also discussed according to relations that they have with the problems
of quality air. Starting from the prior knowledge of the atmospheric composition and fisicochemical
fenomena which happen naturally, we seek to understand the effects from the NOx
concentration increase, as well as the possible secondary pollutants, produced by
photochemical reactions. The NOx emissions data were collected during the period from
February to July in 2011, besides the meteorological conditions like temperature, relative
humidity, wind speed, pluviosity and solar radiation. The collection was done, near to
Industrial District, and Brazil’s largest thermoelectric complex, in the district of Mauazinho.
The automated analysers were used, which store the results through a computerized system,
and the meteorological data were supplied by Meteorogical National Institut (INMET). The
results showed an increasing deterioration of air quality in the region, with 32 overtaking the
limits recommended by the World Health Organization, and June was the most polluted month
in the months surveyed. It concludes that the high number of TPP's and the climatic conditions
in the Amazon Region are decisive for NOx concentration levels. This implies the need to
formulate an environmental air quality diagnostic in the city of Manaus and thus, to support
the government in establishing the requirements for issuance of appropriate levels, by
stationary and mobile pollution sources. / Este trabalho realiza um estudo das concentrações de NOx na atmosfera urbana do município
de Manaus, com foco nas influências meteorológicas específicas da região equatorial. Faz-se
inicialmente, uma contextualização histórica da poluição atmosférica e do uso de combustíveis
fósseis, relacionando a poluição decorrente com o desenvolvimento da cidade e da população
urbana. A importância que os conhecimentos químicos tiveram nesse processo é ressaltada
destacando-se a Ciência Química como a base para todo o desenvolvimento da humanidade.
As dificuldades de fornecimento de energia, cujas origens remontam aos primórdios do
desenvolvimento do Amazonas, o aumento da frota veicular e o crescimento atípico da cidade
de Manaus também são discutidos em função da relação que guardam com os problemas de
qualidade do ar. Partindo do conhecimento prévio da composição atmosférica e dos
fenômenos físicos e químicos que ocorrem naturalmente, busca-se entender os efeitos do
aumento da concentração de NOx, bem como de possíveis poluentes secundários produzidos
por reações fotoquímicas. Foram coletados dados das emissões de NOx, durante o período de
fevereiro a julho de 2011, além das condições meteorológicas como temperatura, umidade
relativa, velocidade do vento, pluviosidade e insolação. A coleta foi feita nas proximidades do
Distrito Industrial e do maior complexo termelétrico do Brasil, no bairro do Mauazinho.
Foram utilizados analisadores automáticos que armazenam os resultados através de um
sistema computadorizado e os dados meteorológicos foram fornecidos pelo Instituto Nacional
de Meteorologia (INMET). Os resultados mostraram um crescente agravamento da qualidade
do ar na região, com 32 ultrapassagens aos limites recomendados pela Organização Mundial
de Saúde, sendo o mês de junho, o mais poluído entre os meses pesquisados. Conclui-se que o
elevado número de UTE’s e as condições climáticas predominantes na região em estudo
tenham sido determinantes para os níveis de concentração dos NOx implicando na necessidade
de formulação do diagnóstico da qualidade do ar ambiental na cidade de Manaus para, dessa
forma, subsidiar o poder público no estabelecimento das exigências de níveis adequados de
emissão das fontes de poluição fixas e móveis.
|
512 |
Inventário de emissões atmosféricas e avaliação de condicionantes meteorológicas: estudo de caso de Três Lagoas / Inventory of atmosferic emissions and meteorological conditionates: studies of Três LagoasEdmilson de Souza 24 April 2009 (has links)
Desde a década de 1930 distintos estudos têm fortemente aumentado o conhecimento acerca da atmosfera da Terra. De fato, nos últimos trinta anos, devido ao intenso avanço científico e tecnológico um progresso real ocorreu nesta área; incluindo os efeitos da poluição do ar. No entanto, os efeitos da poluição do ar, principalmente em regiões urbanas, ainda exigem uma melhor compreensão. No Brasil, grandes áreas metropolitanas como as cidades de São Paulo e Rio de Janeiro possuem significativas pesquisas sobre a atmosfera local; elas estão entre as regiões onde a qualidade do ar é mais bem monitorada no país. Por outro lado, em algumas regiões como o centro-oeste brasileiro, tais estudos são modestos ou mesmo inexistentes. Devido a fatores geográficos e econômicos, algumas regiões do país como a cidade de Três Lagoas (20 \'GRAUS\' 47\' S, 51 \'GRAUS\' 42\' W), leste do Estado de Mato Grosso do Sul, passa por relevantes transformações nos últimos dez anos. Fontes potenciais de poluição do ar e/ou seus precursores surgem através da instalação de novas indústrias (incluindo uma termoelétrica de 240 MW), crescimento da frota veicular, extensas áreas de plantio de floresta de eucalipto para uso industrial (hidrocarbonetos biogênicos), um grande reservatório de hidroelétrica (emissão de metano) e ocorrências sazonais de queimadas. Os resultados obtidos foram organizados em inventários de emissões atmosféricas. Também foram analisadas as concentrações de poluentes e parâmetros meteorológicos. Entre as fontes analisadas, a frota veicular foi considerada a majoritária, sendo responsável por 97% da descarga de monóxido de carbono e cerca de 53% dos óxidos de nitrogênio na atmosfera local. Para os gases poluentes monitorados, as concentrações médias, no período analisado (2005 e 2006), medidos em ppbv foram: \'O IND.3\' = 25 \'+ OU -\' 14,4, NOx = 9,4 \'+ OU -\' 6,6 e \'CO\' = 166,5 \'+ OU -\' 49,8. Outros resultados confirmam a correlação estatística entre parâmetros meteorológicos e a concentração de poluentes. O ozônio, durante setembro/2005, apresentou forte correlação linear com a temperatura (0,76) e média com a radiação solar (0,58). A análise do transporte de hidrocarbonetos biogênicos (floresta de eucalipto) e da pluma de NOx (usina termoelétrica) indica uma participação secundária dessas fontes. De fato, os resultados indicam que os níveis da qualidade do ar de Três Lagoas atendem à legislação vigente no país. / Since the 1930\'s, several studies have strongly increased the knowledge about the Earth atmosphere. Indeed, in the last thirty years, due to intense scientific and technologic improvements a real progress happened in this area; including the effects of air pollution. However, the effects of air pollution, mainly around urban zones, still require a better understanding. In Brazil, large metropolitan areas like São Paulo and Rio de Janeiro already have a good deal of research on their local atmosphere; they are among the regions where air quality is better monitored in country. On other places, like brazilian mid-west, such studies are modest or inexistent. Due to factors as geographical and economical, some regions of the country as the city of Três Lagoas (20 \'GRAUS\' 47\' S, 51 \'GRAUS\' 42\' W), east of Mato Grosso do Sul state, undergone strong transformations in the last ten years. Potential sources of air pollutants and/or its precursors began to show up, brought by the installation of new industries (including a 240MW power-plant), increase of the vehicle fleet, extensive conifer plantation for industrial use (biogenic hydrocarbons), a large hydropower reservoir (methane) and the seasonal occurrence of vegetation burning. The research results were organized on atmospheric emissions inventories. It was also analyzed the pollutants concentrations and meteorological parameters. Among the emissions sources, the vehicle fleet turned to be the major source. It is responsable for 97% of carbon monoxide and 53% of nitrogen oxides of the total mass of pollutants released into local atmosphere. Concerning to the pollutants gases monitored, the mean concentrations, in the analyzed period (2005 and 2006), was measured in ppbv: \'O IND.3\' = 25 \'+ OU -\' 14,4, NOx = 9,4 \'+ OU -\' 6,6 e \'CO\' = 166,5 \'+ OU -\' 49,8. Statistical correlation between meteorological parameters and the pollutants concentration was also confirmed by others research results. The ozone, during September/2005, showed strong linear correlation with temperature (0,76) and moderate to solar radiation (0,58). The transport analyze of biogenic hidrocarbon (eucalyptus forest) and NOx (thermopower plant) plume points to a supporting role of this sources. Indeed, the results proved that the air quality levels of Três Lagoas city is in accordance with the current country legislation.
|
513 |
Conforto térmico e concentração de CO2 em salas de cirurgias e salas de espera para pacientes, climatizadas artificialmente. / Thermal comfort and CO2 concentration in air conditioned operating rooms and waiting rooms for patients.Elaine Gonçalves Ferreira Santana 19 April 2013 (has links)
Nos últimos anos tem havido um aumento no estudo da qualidade do ar interno relacionado aos sistemas de ventilação mecânica e condicionamento do ar. Isso é especialmente fundamental em hospitais, onde a transmissão da contaminação pelo ar é considerada uma das principais causas de aquisição de doenças por pacientes, profissionais de saúde e visitantes. Além disso, essas instituições por abrigarem diversos setores, cada um com uma especificidade e função, exigem diferentes condições de conforto ambiental, sob os aspectos higrotérmico e de qualidade do ar, além do acústico e luminoso. Com o objetivo de avaliar a qualidade o ar, sob os parâmetros de conforto térmico e da concentração de dióxido de carbono em ambientes hospitalares climatizados artificialmente, realizou-se uma investigação de campo em salas de espera e salas de cirurgias de uma amostra de seis edifícios hospitalares na cidade de São Paulo e região metropolitana. Para coleta dos dados foram utilizados instrumentos de monitoramento, portáteis e de elevada precisão, adequados para a realização da pesquisa. Os resultados obtidos a partir da análise desses dados apontaram relevantes problemas relacionados ao conforto e a qualidade do ar. Dentre esses problemas, destacam-se a ausência de controle do diferencial de pressão entre as salas de cirurgias e os corredores; a divergência entre as temperaturas operativas ideais para promoção do conforto térmico para grupos de pessoas com diferentes vestimentas e nível de atividade, ocupando um mesmo ambiente, no caso, as salas de cirurgias; a insuficiência de renovação de ar, especialmente nas salas de espera equipadas com o sistema de climatização do tipo split-system; além da ausência de padronização entre os critérios dos referenciais técnicos mais adotados. Sob esses aspectos, percebeu-se a necessidade de melhoria do conhecimento da interação entre os ocupantes e o ambiente, especialmente naqueles onde o controle se faz necessário para a promoção da saúde. / In recent years has been increased interest in thermal comfort and air quality of indoor environments related to mechanical ventilation systems and air conditioning. This is especially crucial in hospitals where contaminated air transmission is considered a major cause of acquiring disease for patients, health care professionals and visitors. Moreover, these institutions having different sectors, each one with a speciality and function, require different conditions of environmental comfort, in terms of hygrothermal, air quality, acoustic and luminous aspects. In order to evaluate the air quality under the parameters of thermal comfort and carbon dioxide concentration in air conditioning hospital environments, it was carried out a field investigation in waiting rooms and operating rooms in six hospitals in São Paulo and metropolitan region. For data collection were used portable monitoring devices, suitable for research. The results from data analysis indicated significant problems related to thermal comfort and indoor air quality. Among these problems, it can be highlighted the lack of the differential pressure control between the operating rooms and corridors; the divergence among the optimal operative temperatures to provide thermal comfort for different groups of people with different clothing and activity level, occupying the same environment, in this case, the operating rooms; the disregard with the air changes required, especially in waiting rooms equipped with the splitsystem; besides the lack of standardization among the technical references criteria often used. Under these aspects, it is necessary to improve the knowledge of the interaction between the occupants and the environment, especially where the environmental control is decisive to promote the health.
|
514 |
Condições de conforto térmico e desconforto local em salas cirúrgicas. / Thermal comfort and local discomfort conditions in surgical rooms.Victor Barbosa Felix 20 June 2008 (has links)
Hospitais e demais instalações médicas constituem-se em ambientes complexos, que requerem sistemas de tratamento de ar e de ventilação adequados para o conforto e segurança de pacientes, de pessoal e de visitantes. Em ambientes cirúrgicos as condições de conforto térmico precisam ser as melhores possíveis, para que o cirurgião e a equipe médica trabalhem em condições favoráveis para o sucesso do procedimento cirúrgico. Simultaneamente, os riscos de infecção do paciente e dos profissionais de saúde, causadas por partículas transportadas pelo ar, devem ser minimizados. Neste trabalho foram realizadas avaliações experimentais de condições de conforto térmico e desconforto local em salas cirúrgicas com três diferentes tipos de sistemas de distribuição de ar. O procedimento experimental consistiu de medições e avaliações subjetivas (questionários). As avaliações de condições de conforto térmico foram realizadas segundo os critérios de conforto de Fanger e conforme previsto nas normas ISO 7730 e ASHRAE 55. A aplicação do método de Fanger na avaliação de condições de conforto térmico em salas cirúrgicas mostrou-se adequada, embora seja necessário cuidado especial na sua utilização e na análise dos resultados. Verificou-se que é muito difícil prover condições de conforto térmico para toda a equipe cirúrgica, principalmente devido a fatores pessoais como o tipo de vestimenta e o nível de atividade, bem como de fatores específicos do ambiente cirúrgico, como o calor liberado pelo foco cirúrgico. Os resultados obtidos permitiram verificar que o sistema de fluxo unidirecional apresentou melhores condições de conforto térmico. Esse sistema também apresenta um maior potencial de controle de contaminantes no campo cirúrgico. Finalmente, resultados de estudo comparativo com trabalhos de outros autores mostram valores praticamente iguais de temperaturas equivalentes de conforto térmico em torno de 22°C para todos os membros da equipe cirúrgica. Esse resultado é particularmente útil para avaliar diferentes condições ambientais e pessoais em propiciar condições de conforto térmico aos diferentes membros da equipe cirúrgica. / Hospitals and medical centers are complex environments which request special air treatment and ventilation systems for the comfort and safety of patients, personnel and visitors. In surgical environments the thermal comfort conditions need to be the best as possible in order to the surgeons and the medical team work in favorable conditions for the success of the surgical procedure. Simultaneously, the risks of infection caused by airborne particles should be minimized. In the present work experimental evaluations of thermal comfort and local discomfort conditions were carried out for surgical rooms with three different types of air distribution systems. Measurements and subjective evaluations (questionnaires) were accomplished. The evaluations of thermal comfort conditions were done according to the Fanger comfort criteria and as foreseen in the norms ISO 7730 and ASHRAE 55. The use of the Fanger method in the evaluation of thermal comfort conditions in surgical rooms is appropriate, although it is necessary special care in its use and in the analysis of the results. It was verified that it is very difficult to provide conditions of thermal comfort for the whole surgical team, mainly due to personal factors like clothing and activity level, as well as surgical-specific environmental factors like the heat of the surgical focus. The analysis shows that the unidirectional flow system presented better conditions of thermal comfort. Additionally, this system also presents greater potential of pollutants control in the surgical field. Finally, results of comparative study with other authors\' works show practically same values of equivalent temperatures of thermal comfort around 22°C for all of the members of the surgical team. That result is particularly useful to evaluate different environmental and personal conditions in propitiating conditions of thermal comfort to the different members of the surgical team.
|
515 |
Análise experimental da influência do sistema de ventilação e distribuição de ar no conforto térmico e na dispersão e remoção de partículas expiratórias em cabine de aeronave. / Experimental analysis of the influence of the ventilation and air distribution system in the thermal comfort and in the dispersion and removal of expiratory particles in the aircraft cabin.Douglas Fabichak Junior 21 September 2018 (has links)
O conforto térmico e a dispersão e remoção de partículas em cabine de aeronave são função, fundamentalmente, do seu sistema de ventilação e distribuição de ar. Juntamente com a análise da influência do sistema de ventilação por mistura (MV), atualmente utilizado em aviões comerciais, no presente trabalho são propostos e analisados dois novos sistemas, o sistema de distribuição de ar pelo piso (UFAD) e o sistema de ventilação por deslocamento (DV). A análise experimental de condições de desconforto térmico local e de dispersão e remoção de partículas expiratórias foi realizada em um mock-up de uma aeronave comercial com 12 assentos, com 4 assentos por fileira. Os resultados mostram forte influência da temperatura do ar insuflado na cabine, de 18 °C e 22 °C, do ponto de geração de partículas na cabine, em assento junto à fuselagem e junto ao corredor, e da faixa de tamanhos de partículas, principalmente nas faixas de 2,0 a 3,0 µm e de 3,0 a 5,0 µm, de maior interesse no presente trabalho. Por fim, os resultados mostram que o sistema UFAD apresentou o melhor desempenho, tanto quanto ao desconforto térmico devido a correntes de ar, com valores abaixo de 20 % preconizado pelas normas ISO 7730 (2005) e ASHRAE 55 (2013), quanto à menor dispersão de partículas e maior eficiência na remoção de partículas na região de respiração, com eficiência na remoção de partículas maior em até 18,8 % em relação ao sistema DV e em até 41,6 % em relação ao sistema MV. O sistema DV apresentou resultados intermediários com relação ao desconforto térmico local, com pior resultado na região dos pés com média do desconforto térmico local de 22,7 % e muito boa eficiência na remoção de partículas em relação ao sistema convencional MV maior em até 32,0 %. O sistema MV apresentou as piores condições com relação ao desconforto térmico para a região da cabeça e dos pés, com média de pessoas insatisfeitas de até 25,7 %. O sistema MV também apresentou as piores condições com relação à eficiência de remoção de partículas com a maior quantidade total de partículas na região de respiração ao longo da aeronave. / Thermal comfort and particles dispersion and removal in an aircraft cabin depend, essentially, on its ventilation and air distribution system. Together with the analysis of the influence of the mixing ventilation system (MV), used in commercial aircrafts, in the present work two new systems are proposed and analyzed, the underfloor air distribution system (UFAD) and the displacement ventilation system (DV). Experimental analysis of local thermal discomfort conditions and dispersion and removal of expiratory particles was performed in a mock-up of a commercial 12 seat aircraft with 4 seats per row. The results show a strong influence of the temperature ot the air inflated into the cabin, of 18°C and 22°C, of the point of generation of particles in the cabin, at the seat next to the fuselage and near the corridor, and of the particle size range, mainly in the bands of 2.0 to 3.0 µm and 3.0 to 5.0 µm, of greater interest in the present study. Finally, the results show that the UFAD system presented the best performance, as well as the thermal discomfort due to drafts, with values below 20% recommended by ISO 7730 (2005) and ASHRAE 55 (2013), as well as the lower dispersion of particles and greater efficiency in the removal of particles in the respiratory region, with particle removal 18.8% in relation to the DV system and by up to 41.6% in relation to the MV system. The DV system presented intermediate results in relation to the local thermal discomfort, with worse results in the feet region with a mean of the local thermal discomfort of 22.7% and very good particle removal efficiency in relation to the conventional MV system of up to 32, 0%. The MV system presented the worst conditions in relation to the thermal discomfort for the head and feet region, with an unsatisfied average of up to 25.7%. The MV system also presented the worst conditions with respect to the removal efficiency of particles with the highest total amount of particles in the breathing region along the aircraft.
|
516 |
Arquiteturas de distribuição de ar em cabines de aeronaves: análise experimental da dispersão de partículas expiratórias. / Air distribution architectures in aircraft cabins: experimental analysis of expiratory particles dispersion.Douglas Fabichak Junior 13 December 2013 (has links)
O sistema de distribuição de ar comumente utilizado em cabines de aeronaves consiste no insuflamento de ar na parte superior e retorno na parte inferior, com mistura do ar na cabine. Devido à sua característica de mistura, este sistema pode dispersar doenças infecciosas pelo ar na cabine. A eclosão mundial do vírus SARS (Severe Acute Respiratory Syndrome) em 2003 demonstrou que a disseminação de contaminantes aéreos ainda é um evento não controlável, uma vez que foi rapidamente difundido mundo afora, principalmente porque pessoas infectadas viajaram de avião para cidades distantes. Fatos como esses têm motivado governos, empresas e instituições de pesquisa a investirem fortemente em pesquisa e desenvolvimento. Novos sistemas de ventilação e distribuição de ar em aeronaves, baseados em sistemas de ventilação por deslocamento e de distribuição de ar pelo piso, estão começando a ser testados. Neste contexto, no presente trabalho foi realizada análise experimental da dispersão de partículas expiratórias em cabine de aeronave, considerando diferentes arquiteturas de distribuição de ar, em mock-up de 12 lugares, utilizando gerador e contadores de partículas. Os ensaios foram realizados para três arquiteturas de distribuição de ar: sistema de ventilação por mistura (MV), sistema de distribuição de ar pelo piso (UFAD) e sistema pelo piso modificado (UFAD modificado), com a mesma vazão de ar de insuflamento em duas condições de temperatura do ar insuflado na cabine: 18 e 22°C. E com geração de partículas em dois pontos da cabine: perto da fuselagem e perto do corredor. As partículas foram geradas e medidas na altura da zona de respiração, a 1,10 m do piso. Os resultados mostram que o ponto de geração de partículas, bem como a temperatura do ar insuflado na cabine, tem grande influência na dispersão e na concentração de partículas ao longo da cabine. Uma menor temperatura do ar na cabine favorece a formação de plumas térmicas junto aos passageiros, aumentando a eficiência na remoção de partículas da cabine. O sistema UFAD apresentou a menor dispersão e a maior eficiência na remoção de partículas expiratórias da cabine, mostrando-se promissor para utilização também em cabines de aeronaves. O aumento na remoção de partículas expiratórias de 3 a 5 m, do sistema UFAD com relação ao sistema convencional MV, foi de até 63,4%. / The air distribution system commonly used in aircraft cabins consists the air insufflations at the top of the cabin with return of the air at the bottom, with mixing air within the cabin. Due to this mixing characteristic, this system can disperse infectious diseases through the cabin air. The global outbreak of SARS virus (Severe Acute Respiratory Syndrome) in 2003 showed that the spread of airborne contaminants is still an uncontrollable event, since it was quickly spread around the world, mainly because infected people who traveled by plane to distant cities. Facts like these have motivated governments, companies and research institutions to invest heavily in research and development. New ventilation systems and air distribution aircraft based on displacement ventilation systems and underfloor air distribution are beginning to be tested. In this context, the present work was made an experimental analysis of the expiratory particles dispersion in aircraft cabins considering different air distribution architectures in a mock- up containing 12 seats, using a generator and a particle counter. The experiments were performed in three architectures air distribution: mixing ventilation system (MV), underfloor air distribution (UFAD) and the underfloor air distribution modified (UFAD modified), all of them with the same air supply rate, considering two air supply temperature conditions: 18 and 22°C. And particle generation at two points of the cabin: near the fuselage and near the aisle. The particles were generated and measured in the breathing zone, 1,10 m from the floor. The results show that the point of generation of particles, and the air supply temperature, have great influence on the dispersion and particle concentration throughout the cabin. A lower air temperature in the cab favors the formation of thermal plumes within the passengers, increasing the efficiency in removing particles from the cabin. The UFAD system had the lowest dispersion and greater efficiency in removing expiratory particles from the cabin, being promising also for its use in aircraft cabins. The increase in expiratory removal of particles from 3 to 5 microns UFAD system with respect to conventional MV was up to 63.4%.
|
517 |
Monitoramento da qualidade ambiental no mercado municipal da cidade de São Carlos, SP: material particulado em suspensão, temperatura, umidade e ruído / Environmental quality monitoring of the Municipal Market in São Carlos, SP: suspended particulate matter, temperature, humidity and noiseArthur Sanches Rotiroti 28 June 2013 (has links)
Este trabalho apresenta uma caracterização ambiental do Mercado Municipal da cidade de São Carlos-SP, localizado na região central da cidade, onde ocorre grande movimentação de pessoas e veículos, em horário comercial. Foram analisados os níveis de material particulado em suspensão no ar, nas suas frações MP10 e MP2,5, níveis de ruído, temperatura e umidade relativa do ar relativa, nos ambientes internos e externos do Mercado. Os valores das concentrações de material particulado, tanto para MP10, como MP2,5, apresentaram-se, em geral, maiores no ambiente interno do que no externo. Os valores encontrados para MP2,5 chegaram a 66,60 g/m³, no ambiente interno, e 60,56 g/m³, no externo. Para a fração MP10, a concentração interna alcançou o valor de 117,74 g/m³ e a externa atingiu os 134,51 g/m³. Duas metodologias diferentes foram utilizadas para a determinação da concentração de material particulado em suspensão, a gravimetria pelo Personal Enviromental Monitor (PEM), e a fotometria por espalhamento de luz pelo aparelho ADR-1500 e pDR-1500. A técnica da gravimetria apresentou, em geral, os valores mais elevados. Uma análise do material particulado foi realizada, por meio da técnica de Fluorescência de Raio-X, para identificação dos elementos químicos presentes. Foram encontrados: Ba, Ca, K, Zn, S, Fe, e Rb. Já em relação à temperatura e umidade relativa do ar, os níveis oscilaram bastante durante o dia, com médias da temperatura interna entre 14°C e 34°C, e a umidade com valores entre 19% e 58%. Foi calculado o Índice de Calor (Hi - Heat Index), revelando desconforto térmico na maior parte dos dias, com as temperaturas internas normalmente acima das externas. Os níveis de ruído encontrados no ambiente interno e externo chegaram a 71,42 e 85,43 dB(A), respectivamente. Foi aplicado um questionário sobre qualidade ambiental aos funcionários do Mercado: 67% dos respondentes acham o local muito quente e 33 % consideram o local muito ruidoso. / This study presents an environmental characterization of the Municipal Market in the city of São Carlos, SP, located at the downtown area, where there is a great movement of people and vehicles, mainly during business hours. The levels of suspended particulate matter in the air were analyzed, in its fractions PM10 and PM2,5, noise levels, temperature and relative humidity in indoor and outdoor environments of the Market. The concentrations of the particulate material for both MP10 and PM2,5, are presented in general higher in the internal environment than the outer and exceeded the limits of the World Health Organization-WHO. The values for PM2,5 reached to 66,60 g/m³, the internal environment, and 60,56 g/m³, externally. For PM10 fraction, the internal concentration reached a value of 117,74 g/m³ and external reached 134,51 g/m³. Two different methods were used to determine the concentration of suspended particulate matter, gravimetry by The Environmental Monitor-PEM and light scattering photometric by the device ADR-1500 and pDR-1500. The gravimetric technique showed in general the highest values. An analysis of the particulate matter was performed by the technique of X-ray fluorescence for the identification of chemical elements. Were found: Ba, Ca, K, Zn, Fe and Rb. In relation to temperature and relative humidity, levels oscillated during the day, with average of the internal temperature between 14°C and 34°C, and humidity with values between 19% and 58%. Were calculated the Heat Index (Hi), revealing thermal discomfort in most of the days, with internal temperatures usually above the external. The noise levels in the internal and external environment reached 71,42 and 85,43 dB(A), respectively. A questionnaire about the environmental quality was applied on the officials Market: 67% of respondents thought the place was very hot and 33% considered the place very noisy.
|
518 |
Avaliação da qualidade do ar em ambientes internos: biblioteca pública / Indoor air quality investigation: public libraryGuilherme Caetano do Nascimento 01 April 2011 (has links)
Ao longo de quinze meses, foram monitorados na Biblioteca Pública Amadeu Amaral, da cidade de São Carlos, SP, os níveis de temperatura, umidade relativa, ruído, intensidade luminosa, contaminação por dióxido de carbono, material particulado total (MPT) e suas frações respiráveis (MP1, MP2,5, MP7 e MP10), avaliação da taxa de ventilação e ocupação, concentração de bioaerossóis e sua identificação. Além disso, foi aplicado um questionário aos ocupantes do local com o intuito de levantar as principais reclamações e queixas relacionadas à qualidade do ar interior. Os resultados mostraram o desconforto térmico do local em todas as salas monitoradas, altos níveis de ruído proveniente do ambiente externo, inadequações relativas à iluminação do local e necessidade de uma atenção especial à taxa de ocupação do prédio. Durante alguns momentos das medições, os níveis de ruído ultrapassaram a barreira dos 80 dB(A), que é um valor bem acima do recomendado em normas, revelando-se um fator de risco para seus usuários e funcionários. Não foram encontrados problemas relacionados à contaminação biológica do local, analisando a concentração de bactérias e fungos. A taxa de ventilação possui valor adequado para o piso 1 e a concentração de gás carbônico se manteve de acordo com os padrões estabelecidos em normas. As respostas dos questionários confirmam os principais resultados encontrados para a Biblioteca, como os altos níveis de ruído, o desconforto térmico do local e as inadequações da iluminação. As recomendações são pautadas na necessidade de realização de ensaios gravimétricos da concentração de material particulado e o desenvolvimento de estudos específicos para a adoção de medidas mitigadores da poluição sonora e, também, da adequação das salas para o conforto térmico dos ocupantes. / Over fifteen months, levels of temperature, humidity, noise, light intensity, contamination by carbon dioxide, total suspended particles (TSP) and respirable fractions (PM1, PM2.5, PM7 and PM10) were monitored at the Public Library Amadeu Amaral at São Carlos, SP. Investigation of the ventilation rate and occupancy, concentration of bioaerosols and identification were also performed. In addition, a questionnaire was handed over to the occupants of the site in order to raise the main complaints related to indoor air quality. The results showed the discomfort of the place at all rooms monitored, high levels of noise from the outside environment, inadequacies relating to the site illumination and special attention to the building occupancy. During some measurements, the noise levels exceeded the barrier of 80 dB (A), which is above the recommended standards and proved to be a risk factor for its users and employees. No problems were found related to the site biological contamination, analyzing the concentration of bacteria and fungi. The ventilation rate has adequate value to the first floor and carbon dioxide concentration was maintained in accordance with the standards. The questionnaire responses confirm the main findings to the library, such as high noise levels, thermal discomfort and the illumination problem. The main recommendations are based on the need of gravimetric particulate matter investigation and development of specific studies for the adoption of mitigation measures on noise pollution and also the suitability of the rooms to the thermal comfort of occupants.
|
519 |
Caracterização dos ambientes termico, aereo e acustico em sistemas de produção de suinos, nas fases de creche e terminação / Characterization of thermal, aerial and accoustic environment in swine confinement - growing and finishing productionSampaio, Carlos Augusto de Paiva 16 December 2004 (has links)
Orientador: Irenilza de Alencar Naas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-04T02:45:00Z (GMT). No. of bitstreams: 1
Sampaio_CarlosAugustodePaiva_D.pdf: 1948134 bytes, checksum: b2e69a6cda73b5e8d5079c6d3b0df732 (MD5)
Previous issue date: 2004 / Resumo: Emissão e concentração de aerossóis, gases e vapores provenientes do confinamento de animais causam danos à atmosfera, ao ambiente, ao homem e aos animais e às estruturas das instalações. Os contaminantes aéreos possuem efeito negativo sobre a saúde e produtividade dos animais e dos trabalhadores, que expostos a tais substâncias podem desenvolver problemas como irritação do sistema respiratório, pneumonite de hipersensibilidade, bronquite crônica, inflamações das vias aéreas, infecções respiratórias, asma ocupacional, febre e irritação nos olhos, dentre outros. Informações sobre ruídos, gases e poeira e seus efeitos no bem-estar do animal e do trabalhador em sistemas de produção de suínos para as condições brasileiras são escassas, pois estes estudos em sua grande maioria, são relacionados a países de clima temperado, onde as construções são completamente fechadas e o resultado final do ambiente difere das condições brasileiras, além do fator clima e manejo a ser considerado. Este trabalho possui os seguintes objetivos: avaliar o conforto térmico; a concentração de amônia (NH3), sulfeto de hidrogênio (H2S), metano (CH4), monóxido de carbono (CO), oxigênio (O2) e poeira; o ruído e estimar os riscos de exposição ocupacional a estes agentes ambientais. O estudo foi realizado em três granjas de ciclo completo de produção: Granja 1 (creche e terminação, ambos de piso compacto) e Granja 2 (creche de piso semi-ripado e terminação de piso compacto com lâmina d'água), durante o verão e inverno de 2003; Granja 3 (creche de salas com piso semi-ripado e gaiolas), durante o verão de 2002. Nestas instalações, era usada somente a ventilação natural para fins térmicos e higiênicos. Verificou-se que as concentrações médias de H2S e CO ficaram abaixo de 1 ppm e inferiores a 0,1% de CH4 em volume no ar, não ultrapassando os limites recomendados pela CIGR (1994) aos animais e aos limites recomendados pelas NR-15 (1978) e ACGIH (2001) para o trabalhador. A concentração de O2 ficou em média 21%. Com relação ao NH3, foram observadas diferenças (P < 0,05) nas concentrações médias em relação aos horários de alimentação dos animais, às tipologias das instalações e aos períodos avaliados. As análises dos dados revelam a necessidade de se melhorar a qualidade do ar, dando ênfase principalmente aos horários mais quentes e às condições de inverno, já que basicamente o NH3 encontra-se em concentração mais alta em relação à recomendada em diversos estudos. A concentração de poeira foi muito variável, sendo que a concentração de poeira total foi mais alta na creche (0,84 - 9,16 mg.m-3) do que na terminação (0,84 - 3,34 mg.m-3) e a concentração de poeira respirável foi mais alta nas unidades de creche, porém inferior a 3,67 mg.m-3, não apresentando riscos à saúde. As concentrações dessas substâncias (gases e poeira) foram inferiores àquelas verificadas em instalações fechadas. O ruído contínuo e de impacto se manteve nos limites recomendados pelas NR-15 (1978) e ACGIH (2001), podendo-se considerar o ambiente salubre. Entretanto, considerando o ruído de pico observado nos horários de alimentação e vacinação principalmente nas instalações para terminação, recomenda-se o uso de equipamento de proteção auricular. Na Granja 3, notou-se que o ruído contínuo e de pico na sala de creche com gaiolas foi superior ao ruído na sala de piso semi-ripado, o que pode estar relacionado a um maior bem-estar dos animais criados no piso semi-ripado. Verificou-se também a tendência do ruído de se acompanhar as condições de conforto térmico das instalações / Abstract: Emissions and concentrations from livestock buildings must be identified and analyzed with regard potential detrimental or hazardous effects on the atmosphere, man, animals, buildings and environment. Substantial evidence shows that some gases and particulates have a negative effect on health and productivity of animals. Labor in livestock buildings are exposed to a complex mixture of aerial contaminants and some can develop respiratory problems including irritation and inflammation of the respiratory tract, hypersensibility pneumonitits, chronic bronchitis, respiratory infections, occupational asthma and toxin fever and irritation of the eyes. Information about noise, dust and gases concentrations and the effects on animal¿s welfare and the workers in swine systems confinements production are rare in tropical regions. The majorities of the information addresses regions where the livestock buildings are total enclosed and the conditions of climate and manage are different too. This study was carried out during summer and winter of 2002/2003 and the objectives were: to evaluate the noise environment, air quality (NH3, H2S, CH4, CO, O2 and dust concentrations), the environment thermic, and estimate the occupational risk exposition the workers at three commercial swine production facilities: Housing 1 - growing and finishing with full slatted floors, Housing 2 - growing with partially slotted floor (40% of the pen area) and finishing of full slatted floors with thing layer of water in behind to the stalls and Housing 3 - growing with suspend cages and semi-slotted floor rooms of breeding. In the housings was used natural ventilation for thermal and hygiene environment control. The respective concentrations of H2S, CO, O2 and CH4 were less than 1 ppm, less than 1 ppm, 21.0% and less than 0.1% by volume. The concentrations of substances during these measurements are not dangerous of the animals and the workers as according to CIGR (1994), NR-15 (1978) and ACGIH (2001). The average concentration of NH3 presented significant difference (P < 0.05) with regard to feeding schedule, typology and periods available. The analyses of ammonia showed that some schedule mainly during winter are necessary attention especial because these concentrations were higher than most recommended by several studies. Total dust concentrations were the lowest for finishing units (0.84 - 3.34 mg.m-3) and the highest for growing units (0.84 - 9.16 mg.m-3). The respirable dust concentrations were highest than for growing units, and less than 3.67 mg.m-3. These concentrations were less than the limits recommended of the workers. The airborne concentrations of substances measured in the present study were all lower than most of published studies conducted in mainly enclosed swine buildings. The noise level (continuous and impact) were less than recommended by norms (NR-15 and ACGIH), however the peak noise level observed during feed alimentation and other task schedule mainly finishing swine housing recommended ear protection. In Housing 3 observed that noise continuous and peak in the room with suspend cages were highest than semi-slotted floor. These measurements indicated higher welfare the animals in the semi-slotted floor breeding. There was also tendency to increase the noise as thermal comfort environment conditions decreases / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola
|
520 |
Measurement of biogenic hydrocarbon emissions from vegetation in the Lower Fraser Valley, British ColumbiaDrewitt, Gordon 11 1900 (has links)
Biogenic volatile organic compounds (VOCs) are a diverse class of hydrocarbon released
during the normal physiological processes of some species of vegetation. These substances can
participate in many chemical reactions and in some cases have potential to promote the formation
of ground level ozone. The Fraser Valley located in southwestern British Columbia occasionally
experiences these air pollution episodes during the summer. In order to effectively reduce the
frequency and magnitude of these episodes, it is important that we understand the relative role of
biogenic hydrocarbons from the abundant vegetated surfaces in the region.
The thesis presents the results of measurements conducted on four common tree species in
the lower Fraser Valley using a branch enclosure apparatus. Hydrocarbon emission rates from
Cottonwoods trees were approximately one hundred times greater than those from coniferous
trees and were dominated by the compound isoprene. Monoterpenoid emissions from four tree
species were highly variable in magnitude and demonstrated no statistically significant relationship
with temperature. Comparison of the observed results with a simple model from the literature
shows relatively close agreement in the case of isoprene but poor agreement with monoterpene
emissions. Results of these branch enclosure studies were extrapolated to larger scales to yield an
areal emission rate assuming reasonable biomass densities. Isoprene measurements in this study
reveal an areal emission rate approximately twenty times that of the assumed value in current
emissions inventories. This discrepancy could be quite significant considering its magnitude and
the possible sensitivity of the chemical reactions that produce ground level ozone to changes in
isoprene concentration. / Arts, Faculty of / Geography, Department of / Graduate
|
Page generated in 0.0688 seconds