• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 12
  • 10
  • 10
  • 9
  • 7
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da qualidade do ar interior em ambientes educacionais. / Study of indoor air quality in educational environments.

Fakhoury, Nícolas Alexandre 12 May 2017 (has links)
A Qualidade do Ambiente Interior (QAI) é um dos principais fatores que determina a funcionalidade, harmonia, conforto e produtividade em um edifício. A QAI afeta a saúde e o conforto dos ocupantes de um edifício, bem como a habilidade dos mesmos em realizar tarefas, influenciando diretamente na produtividade. Quando a QAI é boa, os ambientes se tornam lugares mais desejáveis para estar, trabalhar e aprender. O ambiente de escolas e universidades pode exercer um impacto significativo na saúde e no aprendizado de crianças e estudantes universitários. A limitação da entrada de poluentes e contaminantes, bem como o fornecimento da quantidade adequada de ar externo filtrado e limpo, melhoram o desempenho acadêmico dos estudantes e não atinge a saúde dos mesmos. Este trabalho apresenta medições de parâmetros físicos e químicos, CO2, PM2,5, PM10, temperatura de bulbo seco e umidade relativa, efetuadas em uma sala de aula do prédio de Engenharia Mecânica da Escola Politécnica da Universidade de São Paulo (EPUSP) os quais os estudantes e professores estavam sujeitos. As medidas foram tomadas no ambiente interno e externo a sala de aula, onde atividades teóricas e práticas eram realizadas. A vazão de ar externo, previamente filtrado, era variada para a redução dos contaminantes gerados internamente. Constatou-se que os particulados PM2,5 e PM10 atingiram concentrações críticas de 6 e 30 vezes maiores do que o limite proposto pelas normas vigentes, respectivamente, bem como a concentração de CO2 que atingiu 3 vezes o limite recomendado. Porém, observou-se que o aumento da vazão de ar externo em aproximadamente 2200 m³/h foi suficiente para a diminuição da concentração de PM10 em 50% nos primeiros 20 minutos. Apesar da diminuição da concentração, a vazão recomendada de ar externo por pessoa não foi suficiente para a concentração de material particulado atingir os limites aceitáveis. Por fim, apresenta-se uma proposta de projeto detalhado de dois sistemas independentes de tratamento de ar que permitirão a realização de experimentos e estudos sobre a QAI, podendo-se variar a vazão de ar externo e a classe de filtragem da recirculação e da tomada de ar externo para dois laboratórios do Departamento de Engenharia Mecânica da EPUSP, que podem dar sequência aos estudos deste trabalho. / The Indoor Environmental Quality (IEQ) is one of the main factors that determines the functionality, harmony, comfort and productivity in a building. The IEQ affects the health and comfort of the occupants of a building, as well as the ability of them to perform tasks, influencing directly in productivity. When IEQ is good, the environments become more desirable places to be in, work and learn. The indoor environment of schools and universities can have a significant impact on the health and learning of children and college students. The limitation of input of pollutants and contaminants, as well as providing the appropriate amount of filtered and clean outside air, improve the academic performance of students and does not affect the health of the same. This paper presents measurements of physical and chemical parameters, CO2, PM2,5, PM10, dry bulb temperature and relative humidity, made in a classroom of the Mechanical Engineering building of the Polytechnic School of the University of São Paulo (EPUSP) which students and teachers were subject. The measurements were taken in the internal and external environment of the classroom, where theoretical and practical activities were conducted. The flow of outside air, previously filtered, was varied for the reduction of contaminants generated internally. It was found that the particulate PM2,5 and PM10 achieved critical concentrations of 6 and 30 times greater than the limit proposed by the current standards, respectively, and that the concentration of CO2 reached 3 times the recommended limit. However, it was observed that increasing outside air flow of approximately 2200 m³/h was enough to decrease the concentration of PM10 in 50% at the first 20 minutes. Despite the decreased concentration, the recommended flow of outside air per person was not enough for the concentration of particulate matter reaches the acceptable limits. Finally, a detailed project proposal is presented of two independent air treatment systems that will allow performing experiments and studies on the IEQ, being able to vary the flow of outside air and, the filters of the recirculation and external air intake for two laboratories of the Department of Mechanical Engineering of EPUSP, that can follow the studies of this work.
12

Estudo da qualidade do ar interior em ambientes educacionais. / Study of indoor air quality in educational environments.

Nícolas Alexandre Fakhoury 12 May 2017 (has links)
A Qualidade do Ambiente Interior (QAI) é um dos principais fatores que determina a funcionalidade, harmonia, conforto e produtividade em um edifício. A QAI afeta a saúde e o conforto dos ocupantes de um edifício, bem como a habilidade dos mesmos em realizar tarefas, influenciando diretamente na produtividade. Quando a QAI é boa, os ambientes se tornam lugares mais desejáveis para estar, trabalhar e aprender. O ambiente de escolas e universidades pode exercer um impacto significativo na saúde e no aprendizado de crianças e estudantes universitários. A limitação da entrada de poluentes e contaminantes, bem como o fornecimento da quantidade adequada de ar externo filtrado e limpo, melhoram o desempenho acadêmico dos estudantes e não atinge a saúde dos mesmos. Este trabalho apresenta medições de parâmetros físicos e químicos, CO2, PM2,5, PM10, temperatura de bulbo seco e umidade relativa, efetuadas em uma sala de aula do prédio de Engenharia Mecânica da Escola Politécnica da Universidade de São Paulo (EPUSP) os quais os estudantes e professores estavam sujeitos. As medidas foram tomadas no ambiente interno e externo a sala de aula, onde atividades teóricas e práticas eram realizadas. A vazão de ar externo, previamente filtrado, era variada para a redução dos contaminantes gerados internamente. Constatou-se que os particulados PM2,5 e PM10 atingiram concentrações críticas de 6 e 30 vezes maiores do que o limite proposto pelas normas vigentes, respectivamente, bem como a concentração de CO2 que atingiu 3 vezes o limite recomendado. Porém, observou-se que o aumento da vazão de ar externo em aproximadamente 2200 m³/h foi suficiente para a diminuição da concentração de PM10 em 50% nos primeiros 20 minutos. Apesar da diminuição da concentração, a vazão recomendada de ar externo por pessoa não foi suficiente para a concentração de material particulado atingir os limites aceitáveis. Por fim, apresenta-se uma proposta de projeto detalhado de dois sistemas independentes de tratamento de ar que permitirão a realização de experimentos e estudos sobre a QAI, podendo-se variar a vazão de ar externo e a classe de filtragem da recirculação e da tomada de ar externo para dois laboratórios do Departamento de Engenharia Mecânica da EPUSP, que podem dar sequência aos estudos deste trabalho. / The Indoor Environmental Quality (IEQ) is one of the main factors that determines the functionality, harmony, comfort and productivity in a building. The IEQ affects the health and comfort of the occupants of a building, as well as the ability of them to perform tasks, influencing directly in productivity. When IEQ is good, the environments become more desirable places to be in, work and learn. The indoor environment of schools and universities can have a significant impact on the health and learning of children and college students. The limitation of input of pollutants and contaminants, as well as providing the appropriate amount of filtered and clean outside air, improve the academic performance of students and does not affect the health of the same. This paper presents measurements of physical and chemical parameters, CO2, PM2,5, PM10, dry bulb temperature and relative humidity, made in a classroom of the Mechanical Engineering building of the Polytechnic School of the University of São Paulo (EPUSP) which students and teachers were subject. The measurements were taken in the internal and external environment of the classroom, where theoretical and practical activities were conducted. The flow of outside air, previously filtered, was varied for the reduction of contaminants generated internally. It was found that the particulate PM2,5 and PM10 achieved critical concentrations of 6 and 30 times greater than the limit proposed by the current standards, respectively, and that the concentration of CO2 reached 3 times the recommended limit. However, it was observed that increasing outside air flow of approximately 2200 m³/h was enough to decrease the concentration of PM10 in 50% at the first 20 minutes. Despite the decreased concentration, the recommended flow of outside air per person was not enough for the concentration of particulate matter reaches the acceptable limits. Finally, a detailed project proposal is presented of two independent air treatment systems that will allow performing experiments and studies on the IEQ, being able to vary the flow of outside air and, the filters of the recirculation and external air intake for two laboratories of the Department of Mechanical Engineering of EPUSP, that can follow the studies of this work.
13

Análise do escoamento do ar em uma sala cirúrgica via simulação em CFD. / Air flow analysis in an operating room for simulation CFD.

Silva, Cibele Alves da 21 July 2016 (has links)
Com a tendência em se construírem edifícios selados por motivos de climatização, controle de ruído e estéticos, acabou provocando um aumento nos casos de problemas relacionados à qualidade do ar de interiores (QAI) de tais ambientes. Os principais problemas relacionados à má qualidade do ar interno são a ventilação inadequada (maior parte dos casos), seguido de contaminantes do ar externo, contaminantes do ar interno (gerados internamente) e, em menor escala, materiais de construção e micro-organismos. No caso específico de uma edificação hospitalar, a qualidade do ar pode exercer uma influência direta e significativa na ocorrência de infecções hospitalares. O nível de contaminação é influenciado principalmente pelo tipo de sistema de condicionamento de ar. Daí a necessidade de um controle intenso dos contaminantes presentes no ar desse local. Assim, os sistemas de distribuição de ar desempenham uma tarefa fundamental em uma sala cirúrgica para a garantia da segurança e conforto térmico ao paciente, equipe cirúrgica. O retorno de ar também exerce uma função muito importante na eliminação do ar contaminado gerado no interior de uma sala cirúrgica. Esse retorno ocorre através das chamadas grelhas de retorno. Dado à limitação dos estudos analíticos e o alto custo das investigações experimentais, é grande relevância uma investigação numérico-computacional do escoamento do ar de uma sala cirúrgica, visando analisar o comportamento do fluxo de ar e da temperatura do ar. O foco desse trabalho é verificar, via simulação computacional em CFD (Computational Fluid Dynamics), a efetividade do sistema de distribuição de ar usado em centros cirúrgicos no que diz respeito ao controle do ar, com o intuito de se alcançar uma qualidade do ar adequada. Para validar o modelo computacional, realizou-se também a parte experimental, na qual foram feitas medições e coletas de dados em campo para comparação com os resultados das simulações. O estudo de caso considerado nesse trabalho foi uma das salas do centro cirúrgico do Hospital Universitário (HU) da Universidade de São Paulo. / Due the trend to construct sealed buildings for air conditioning purposes, noise control and aesthetics, problems regarding interior air quality (IAQ) of such environments have been occured. The main issues related to bad indoor air quality are inadequate ventilation (most part of the cases), followed by outdoor air contaminants, indoor air contaminants (internally generated) and, in a smaller scale, construction materials and microorganisms. In the specific case of a hospital building, air quality can have a direct and significant influence on the occurrence of nosocomial infections. The level of contamination is mainly influenced type air conditioning system. Hence the need for intensive control of contaminants in local air. Therefore, the air distribution systems play a fundamental task inside a surgical room for safety and thermal comfort of the patient and surgical team. The return air also plays a very important role in eliminating contaminated air generated within an operating room. This return takes place through so-called return grills. Due to the limitation of analytical studies and the high cost of experimental research, it is very relevant a numerical-computational investigation of the air flow of an operating room in order to analyze the air flow behavior and the air temperature. The focus of this study is to verify, via computer simulation based on CFD (Computational Fluid Dynamics), the effectiveness of the air distribution system used in surgical centers regarding the control of air, in order to achieve a proper quality of air. To validate the computer model, field measurements have been carried out and data have been collected for comparison with the simulation results. The case study to be considered for this project is the surgical room of the University Hospital of the University of São Paulo.
14

Avaliação da qualidade do ar em unidades de terapia intensiva e sua correlação com o ambiente externo e a saúde dos trabalhadores / Evaluation of intensive care units air quality and its correlation with both external environment and workers\' health

Marilia Jukemura Miyagusko 12 September 2008 (has links)
Nos locais de trabalho, a qualidade do ar pode interferir na performance dos trabalhadores e no risco de doenças. Sabe-se que a qualidade do ar interior pode ser afetada pelos poluentes gerados no ambiente exterior. Nos hospitais, estes temas têm sido insuficientemente analisados e nas unidades de terapia intensiva eles ainda não foram investigados. Os objetivos deste estudo foram analisar a correlação entre os níveis de poluentes medidos dentro e fora das unidades de terapia intensiva e investigar a associação entre a qualidade do ar nas unidades e a saúde dos trabalhadores. Oito unidades de terapia intensiva localizadas em quatro hospitais diferentes foram incluídas neste estudo. Níveis de poluentes, temperatura e umidade relativa do ar foram medidos dentro e fora das unidades, simultaneamente, durante períodos de sete dias específicos para cada unidade. Monitores automáticos foram usados para o monitoramento do MP2,5, enquanto monitores passivos foram usados para as medidas de NO2 e O3. Um questionário de sintomas foi aplicado a cada trabalhador das unidades de terapia intensiva que concordou em participar do estudo. Para testar diferenças nos poluentes e nas variáveis meteorológicas em cada unidade (dentro e fora) adotamos o teste t de Student ou o teste U de Mann-Whitney. Para testar diferenças entre a unidades nós adotamos o teste de análise de variância para amostras independentes (ANOVA) e o teste HSD-Tukey, quando necessário. Adotamos os coeficientes de correlação de Pearson ou de Spearman para avaliar correlações entre as medidas interiores e exteriores em cada unidade. Para as associações entre os sintomas e o local de trabalho nós adotamos o teste de qui-quadrado de Pearson ou o teste exato de Fisher. A unidade 1 apresentou a maior média interior de MP2,5 (33,9 g/m3; Desvio Padrão - DP = 44,2), estatisticamente diferente das demais unidades (p < 0,05). Além disso, este valor foi quase 16 vezes maior do que a média de MP2,5 observada na unidade 6 (2,1 g/m3; DP = 3,4), a menos poluída. Em cinco unidades, as medidas interiores e exteriores de MP2,5 apresentaram correlações estatisticamente significativas (p < 0,05). Tanto para o NO2 quanto para o O3, os valores exteriores foram maiores do que os interiores e não ouve correlação entre eles. Entre os 18 sintomas investigados, dores nas costas, ombros e pescoço (65%), cefaléia (65%), cansaço e fadiga (62%), tensão e irritabilidade (58%), coriza (51%), espirros (45%), vista cansada (44%), olhos secos (42%), dor de garganta (38%), dificuldade de concentração (35%) e tosse (27%) foram os mais relatados. As freqüências de sintomas foram semelhantes em todas as unidades. Não foram observadas associações entre a qualidade do ar interior e os sintomas relatados. Estes resultados mostraram que o isolamento entre os ambientes internos e externos através dos sistemas de ar condicionado pode variar permitindo altas concentrações de partículas finas interiormente. Além disso, a falta de correlações entre os gases dentro e fora das unidades indica a presença de fontes interiores para os dois poluentes. Potenciais associações entre a qualidade do ar nas unidades e sintomas de doenças requerem investigações adicionais / In work facilities, air quality can interfere in workers performance and in diseases´ risk. It is well known that indoor air quality can be affected by pollutants generated outdoor. In hospitals these topics have been insufficiently investigated and in intensive care units they have not been explored yet. The aims of this study were to analyze the correlation between indoor and outdoor levels of air pollutants in intensive care units and investigating the association between indoor air quality and workers health. Eight intensive care units located in four different hospitals were included in this study. Indoor and outdoor levels of air pollutants, temperature and relative humidity were measured simultaneously in each unit along unit-specific seven-day periods. Automatic monitors were used to measure PM2.5 while passive samplers were adopted to measure both NO2 and O3. A questionnaire of symptom was applied to each intensive care unit worker that agreed in participating of the study. In order to test differences in pollutants and weather variables measurements intra-units (inside and outside) we adopted the Student t test or Mann-Whitney U test. To test differences inter-units we adopted one-way analysis of variance for independent samples (ANOVA) and the Tukeys Honestly Significantly Different post-hoc test when necessary. We adopted Pearson correlation coefficients or Spearman correlation coefficients to investigate correlations between indoor and outdoor measures. For associations between symptoms and place of work we adopted qui-square test or Fishers exact test. Unit 1 presented the highest indoor PM2.5 mean (33.9 g/m3; Standard Deviation-SD = 44.2) and it was statistically different from all other indoor measures (p < 0.05). Also, it was almost sixteen fold higher than indoor PM2.5 mean in unit 6 (2.1 g/m3; SD = 3.4), the cleanest one. In five units, indoor and outdoor levels of PM2,5 presented statistically significant correlations (p < 0.05). For both NO2 and O3, outside values were higher than those measured inside and there were no correlations between indoor and outdoor measures. From 18 investigated symptoms, pain in back, shoulders or neck (65%), headache (65%), tiredness or fatigue (62%), tension and irritability (58%), runny nose (51%), sneezing (45%), eyestrain (44%), dry eyes (42%), sore and dry throat (38%), difficult of concentrating (35%) and cough (27%) were the most reported. Frequency of symptoms were similar in all units. There were not associations between indoor air quality and reported symptoms. These results showed that isolation between indoor and outdoor environments through air conditioning systems may vary allowing high indoor concentrations of fine particles. Moreover, the lack of correlation between indoor and outdoor gaseous pollutants indicates the presence of indoor sources of both pollutants. Potential associations between indoor air quality and disease symptoms require additional investigation
15

Avaliação da qualidade do ar em unidades de terapia intensiva e sua correlação com o ambiente externo e a saúde dos trabalhadores / Evaluation of intensive care units air quality and its correlation with both external environment and workers\' health

Miyagusko, Marilia Jukemura 12 September 2008 (has links)
Nos locais de trabalho, a qualidade do ar pode interferir na performance dos trabalhadores e no risco de doenças. Sabe-se que a qualidade do ar interior pode ser afetada pelos poluentes gerados no ambiente exterior. Nos hospitais, estes temas têm sido insuficientemente analisados e nas unidades de terapia intensiva eles ainda não foram investigados. Os objetivos deste estudo foram analisar a correlação entre os níveis de poluentes medidos dentro e fora das unidades de terapia intensiva e investigar a associação entre a qualidade do ar nas unidades e a saúde dos trabalhadores. Oito unidades de terapia intensiva localizadas em quatro hospitais diferentes foram incluídas neste estudo. Níveis de poluentes, temperatura e umidade relativa do ar foram medidos dentro e fora das unidades, simultaneamente, durante períodos de sete dias específicos para cada unidade. Monitores automáticos foram usados para o monitoramento do MP2,5, enquanto monitores passivos foram usados para as medidas de NO2 e O3. Um questionário de sintomas foi aplicado a cada trabalhador das unidades de terapia intensiva que concordou em participar do estudo. Para testar diferenças nos poluentes e nas variáveis meteorológicas em cada unidade (dentro e fora) adotamos o teste t de Student ou o teste U de Mann-Whitney. Para testar diferenças entre a unidades nós adotamos o teste de análise de variância para amostras independentes (ANOVA) e o teste HSD-Tukey, quando necessário. Adotamos os coeficientes de correlação de Pearson ou de Spearman para avaliar correlações entre as medidas interiores e exteriores em cada unidade. Para as associações entre os sintomas e o local de trabalho nós adotamos o teste de qui-quadrado de Pearson ou o teste exato de Fisher. A unidade 1 apresentou a maior média interior de MP2,5 (33,9 g/m3; Desvio Padrão - DP = 44,2), estatisticamente diferente das demais unidades (p < 0,05). Além disso, este valor foi quase 16 vezes maior do que a média de MP2,5 observada na unidade 6 (2,1 g/m3; DP = 3,4), a menos poluída. Em cinco unidades, as medidas interiores e exteriores de MP2,5 apresentaram correlações estatisticamente significativas (p < 0,05). Tanto para o NO2 quanto para o O3, os valores exteriores foram maiores do que os interiores e não ouve correlação entre eles. Entre os 18 sintomas investigados, dores nas costas, ombros e pescoço (65%), cefaléia (65%), cansaço e fadiga (62%), tensão e irritabilidade (58%), coriza (51%), espirros (45%), vista cansada (44%), olhos secos (42%), dor de garganta (38%), dificuldade de concentração (35%) e tosse (27%) foram os mais relatados. As freqüências de sintomas foram semelhantes em todas as unidades. Não foram observadas associações entre a qualidade do ar interior e os sintomas relatados. Estes resultados mostraram que o isolamento entre os ambientes internos e externos através dos sistemas de ar condicionado pode variar permitindo altas concentrações de partículas finas interiormente. Além disso, a falta de correlações entre os gases dentro e fora das unidades indica a presença de fontes interiores para os dois poluentes. Potenciais associações entre a qualidade do ar nas unidades e sintomas de doenças requerem investigações adicionais / In work facilities, air quality can interfere in workers performance and in diseases´ risk. It is well known that indoor air quality can be affected by pollutants generated outdoor. In hospitals these topics have been insufficiently investigated and in intensive care units they have not been explored yet. The aims of this study were to analyze the correlation between indoor and outdoor levels of air pollutants in intensive care units and investigating the association between indoor air quality and workers health. Eight intensive care units located in four different hospitals were included in this study. Indoor and outdoor levels of air pollutants, temperature and relative humidity were measured simultaneously in each unit along unit-specific seven-day periods. Automatic monitors were used to measure PM2.5 while passive samplers were adopted to measure both NO2 and O3. A questionnaire of symptom was applied to each intensive care unit worker that agreed in participating of the study. In order to test differences in pollutants and weather variables measurements intra-units (inside and outside) we adopted the Student t test or Mann-Whitney U test. To test differences inter-units we adopted one-way analysis of variance for independent samples (ANOVA) and the Tukeys Honestly Significantly Different post-hoc test when necessary. We adopted Pearson correlation coefficients or Spearman correlation coefficients to investigate correlations between indoor and outdoor measures. For associations between symptoms and place of work we adopted qui-square test or Fishers exact test. Unit 1 presented the highest indoor PM2.5 mean (33.9 g/m3; Standard Deviation-SD = 44.2) and it was statistically different from all other indoor measures (p < 0.05). Also, it was almost sixteen fold higher than indoor PM2.5 mean in unit 6 (2.1 g/m3; SD = 3.4), the cleanest one. In five units, indoor and outdoor levels of PM2,5 presented statistically significant correlations (p < 0.05). For both NO2 and O3, outside values were higher than those measured inside and there were no correlations between indoor and outdoor measures. From 18 investigated symptoms, pain in back, shoulders or neck (65%), headache (65%), tiredness or fatigue (62%), tension and irritability (58%), runny nose (51%), sneezing (45%), eyestrain (44%), dry eyes (42%), sore and dry throat (38%), difficult of concentrating (35%) and cough (27%) were the most reported. Frequency of symptoms were similar in all units. There were not associations between indoor air quality and reported symptoms. These results showed that isolation between indoor and outdoor environments through air conditioning systems may vary allowing high indoor concentrations of fine particles. Moreover, the lack of correlation between indoor and outdoor gaseous pollutants indicates the presence of indoor sources of both pollutants. Potential associations between indoor air quality and disease symptoms require additional investigation
16

Avaliação da qualidade do ar em ambientes hospitalares: ocorrência e diversidade do gênero Aspergillus / Air quality evaluation of hospital environments: occurrence and diversity of gender aspergillus

Ziehe, Érica Mendonça January 2014 (has links)
Submitted by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-06-19T19:00:16Z No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-06-19T19:00:29Z (GMT) No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-06-19T19:00:40Z (GMT) No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) / Made available in DSpace on 2015-06-19T19:00:40Z (GMT). No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Programa de Pós-Graduação em Vigilância Sanitária / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos. Rio de Janeiro, RJ, Brasil. / A qualidade do ar em ambientes internos vem recebendo uma crescente atenção no Brasil na última década, e seus efeitos sobre a saúde humana têm sido objeto de intensivos estudos devido à grande diversidade de substâncias químicas, particulados e agentes biológicos encontrados nestes ambientes. Os contaminantes biológicos mais encontrados são principalmente fungos e bactérias. Nesse contexto, a ANVISA adotou os fungos como indicadores biológicos da qualidade do ar por meio da Resolução n° 9 de 16 de janeiro de 2003. O objetivo desse trabalho foi determinar a qualidade do ar de dois Hospitais Públicos. Avaliações quantitativas e qualitativas de contaminantes fungicos viáveis foram realizadas, para o controle e prevenção de riscos à saúde dos trabalhadores, pacientes e frequentadores destes ambientes. Além de isolar e identificar espécies do gênero Aspergillus para um levantamento das espécies mais frequentes no interior dos hospitais, também foram avaliadas a influência da temperatura e umidade relativa do ar nos níveis de contaminação. Foi proposta uma tabela de fator de risco em relação as espécies isoladas do gênero Aspergillus. As coletas das amostras de ar foram realizadas entre os anos de 2006 e 2007 e executadas de acordo com a Resolução n° 9 de 16 de janeiro de 2003 da ANVISA. As análises microbiológicas foram realizadas no Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos do Instituto Oswaldo Cruz. Foram isolados um total de 2.978 fungos, onde 30% das amostras foram positivas para Aspergillus, dando um total de 360 cepas isoladas e identificadas a nível de espécie. As contagens variaram de 1375 UFC/m3 de ar a 7 UFC/m3 de ar, e as espécies do gênero Aspergillus mais encontradas foram A. flavus (24%), A. japonicus (16%), A. oryzae (15%), A. niger (15%), A. awamori (6%), A. fumigatus (4%). As maiores contagens foram registradas no outono e inverno e as menores foram na primavera e no verão, e as analises de correlação mostraram uma tendência da umidade relativa do ar influenciando os níveis de contaminação. Após todas as análises podemos concluir que se faz necessário o estabelecimento de normas fundamentadas em pesquisas, considerando as atividades e o tipo de usuário, buscando novos valores de VMR e indicando os microrganismos importantes como possíveis indicadores na má qualidades do ar de interiores. / The indoor air quality has received increasing attention in Brazil in the last decade, and its effects on human health have been the subject of intensive studies due to the wide variety of chemicals, particulates and biological agents found in these environments. Biological contaminants most commonly found are mainly fungi and bacteria. In this context, ANVISA adopted fungi as biological indicators of air quality through Resolution No. 9 of January 16, 2003. The aim of this study was to determine the air quality of the two Public Hospitals. Quantitative and qualitative evaluations of viable antifungal contaminants were performed for the control and prevention of health risks to workers, patients and patrons of these environments. In addition to isolating and identifying species of the genus Aspergillus to a survey of the most common species within hospitals, also the influence of temperature and relative humidity levels of contamination were evaluated. A table of risk factors regarding the isolated species of the genus Aspergillus was proposed. The collection of air samples were performed between the years 2006 and 2007 and executed in accordance with Resolution No. 9 of 16 January 2003 of ANVISA. Microbiological analyzes were performed at the Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos do Instituto Oswaldo Cruz. A total of 2,978 fungi were isolated, where 30 % of the samples were positive for Aspergillus, giving a total of 360 strains isolated and identified to species level. The counts ranged from 1375 CFU/m3 air at 7 CFU/m3 air, and the most frequent species of the genus Aspergillus were A. flavus (24%), A. japonicus (16%), A. oryzae (15%), A. niger (15%), A. awamori (6%), A. fumigatus (4%). The highest counts were recorded in autumn and winter and the lowest were in the spring and summer, and correlation analysis showed a trend of relative humidity influencing contamination levels. After all the analysis we can conclude that it is necessary to establish standards grounded in research, considering the activities and the type of user, seeking new VMR values and indicating the important organisms as possible indicators in poor quality of indoor air.
17

Análise do escoamento do ar em uma sala cirúrgica via simulação em CFD. / Air flow analysis in an operating room for simulation CFD.

Cibele Alves da Silva 21 July 2016 (has links)
Com a tendência em se construírem edifícios selados por motivos de climatização, controle de ruído e estéticos, acabou provocando um aumento nos casos de problemas relacionados à qualidade do ar de interiores (QAI) de tais ambientes. Os principais problemas relacionados à má qualidade do ar interno são a ventilação inadequada (maior parte dos casos), seguido de contaminantes do ar externo, contaminantes do ar interno (gerados internamente) e, em menor escala, materiais de construção e micro-organismos. No caso específico de uma edificação hospitalar, a qualidade do ar pode exercer uma influência direta e significativa na ocorrência de infecções hospitalares. O nível de contaminação é influenciado principalmente pelo tipo de sistema de condicionamento de ar. Daí a necessidade de um controle intenso dos contaminantes presentes no ar desse local. Assim, os sistemas de distribuição de ar desempenham uma tarefa fundamental em uma sala cirúrgica para a garantia da segurança e conforto térmico ao paciente, equipe cirúrgica. O retorno de ar também exerce uma função muito importante na eliminação do ar contaminado gerado no interior de uma sala cirúrgica. Esse retorno ocorre através das chamadas grelhas de retorno. Dado à limitação dos estudos analíticos e o alto custo das investigações experimentais, é grande relevância uma investigação numérico-computacional do escoamento do ar de uma sala cirúrgica, visando analisar o comportamento do fluxo de ar e da temperatura do ar. O foco desse trabalho é verificar, via simulação computacional em CFD (Computational Fluid Dynamics), a efetividade do sistema de distribuição de ar usado em centros cirúrgicos no que diz respeito ao controle do ar, com o intuito de se alcançar uma qualidade do ar adequada. Para validar o modelo computacional, realizou-se também a parte experimental, na qual foram feitas medições e coletas de dados em campo para comparação com os resultados das simulações. O estudo de caso considerado nesse trabalho foi uma das salas do centro cirúrgico do Hospital Universitário (HU) da Universidade de São Paulo. / Due the trend to construct sealed buildings for air conditioning purposes, noise control and aesthetics, problems regarding interior air quality (IAQ) of such environments have been occured. The main issues related to bad indoor air quality are inadequate ventilation (most part of the cases), followed by outdoor air contaminants, indoor air contaminants (internally generated) and, in a smaller scale, construction materials and microorganisms. In the specific case of a hospital building, air quality can have a direct and significant influence on the occurrence of nosocomial infections. The level of contamination is mainly influenced type air conditioning system. Hence the need for intensive control of contaminants in local air. Therefore, the air distribution systems play a fundamental task inside a surgical room for safety and thermal comfort of the patient and surgical team. The return air also plays a very important role in eliminating contaminated air generated within an operating room. This return takes place through so-called return grills. Due to the limitation of analytical studies and the high cost of experimental research, it is very relevant a numerical-computational investigation of the air flow of an operating room in order to analyze the air flow behavior and the air temperature. The focus of this study is to verify, via computer simulation based on CFD (Computational Fluid Dynamics), the effectiveness of the air distribution system used in surgical centers regarding the control of air, in order to achieve a proper quality of air. To validate the computer model, field measurements have been carried out and data have been collected for comparison with the simulation results. The case study to be considered for this project is the surgical room of the University Hospital of the University of São Paulo.
18

[en] INDOOR PROPAGATION MEASUREMENTS AT 28 AND 38 GHZ FOR APPLICATION IN THE 5TH GENERATION CELLULAR SYSTEMS / [pt] MEDIÇÕES DE PROPAGAÇÃO EM AMBIENTES FECHADOS NAS FAIXAS DE 28 E 38 GHZ PARA APLICAÇÃO EM SISTEMAS CELULARES DE QUINTA GERAÇÃO

CRISTINE SIMOES FELISBINO 18 April 2022 (has links)
[pt] O uso de dispositivos móveis cresceu exponencialmente nos últimos anos, tornando-se um desafio a melhoria da qualidade de sinal e o pleno atendimento a serviços que exigem altas taxas de dados e baixa latência. A fim de atender a crescente demanda de tráfego, as faixas de freqüências de ondas milimétricas começam a ser exploradas para aplicação à Quinta Geração de Comunicações Móveis. A partir de medições realizadas em ambientes fechados, nas faixas de freqüências de 28 GHz e 38 GHz, foi possível analisar o canal de comunicação com base nos modelos propagação para as faixas de freqüências de ondas milimétricas. / [en] Mobile usage has grown exponentially in recent years, making it a challenge to improve signal quality and fully support to services that require high data rates and low latency. In order to meet the growing traffic demand, millimeter-wave frequency bands are being explored for application to the 5th Generation of Mobile Communications. From measurements performed in indoor environments, in the 28 GHz and 38 GHz frequency range, it was possible to analyze the communication channel based on the propagation models for the millimeter wave frequency bands.

Page generated in 0.0574 seconds