• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Explorando a espectrometria de absorção atômica com atomização eletrotérmica e amostragem direta em superfície metálica para a determinação de bário / Feasibility to use metalic platform to the graphite tube of the electrothermal atomic absorption spectrometry for barium determination

Scatamachia, Daniela de Santi 17 March 2006 (has links)
A eficiência de atomização do bário, em superfície grafítica, é fortemente afetada pela formação de espécies refratárias, como carbetos e óxidos. Várias tentativas vêm sendo propostas no sentido de melhorar o limite de detecção do bário em espectrometria de absorção atômica com forno de grafite. Nesse sentido, o presente trabalho teve como objetivo estudar a viabilidade de se utilizar uma plataforma de tungstênio adaptada ao tubo de grafite do espectrômetro de absorção atômica, visando melhorar a eficiência de atomização do bário bem como a sua determinação em petróleo, óleos lubrificantes, água do mar e água mineral. O sistema proposto constituiu-se de uma plataforma de tungstênio com superfície modificada eletroliticamente com ródio, adaptada a um tubo de grafite com parede interna modificada com irídio. A mistura de 10% (v/v-1) H2 + 90% (v/v-1) Ar como gás de purga aumentou a eficiência de atomização, o tempo de vida do tubo de grafite e da plataforma. O uso de 10 µg de (NH4)2HPO4 como modificador químico foi indispensável para a determinação de bário em água mineral e de mar. O limite de detecção foi de 3,5+/-0,3 µg L-1 e a massa característica de 2,1 pg. Com a plataforma de tungstênio modificada com ródio foi possível gerar um sinal transiente de absorbância com temperatura de atomização de 2400 oC, com tempo de residência de, aproximadamente, 0,5 s, contra uma temperatura de atomização de 2600 oC para o forno de grafite, com tempo de residência de 15 s. A vida útil da plataforma de tungstênio, modificada com ródio, e do tubo de grafite foram, respectivamente, 200 e 750 ciclos de aquecimento. / The atomization efficiency of barium in graphite furnace is strongly affected by the refractory species formation, such as, carbides and oxides. Several attempts have been done to overcome these drawbacks and to improve the sensitivity of barium in electrothermal atomic absorption spectrometry. Thus the aim of the present work was to propose a tungsten platform inserted into the graphite tube of the atomic absorption spectrometer for the determination of barium in petrol, lubrificating oil, drinking water and seawater. The proposed system consisted of a tungsten platform electrolitically modified with rhodium and a graphite tube with the internal wall modified with iridium. The mixture of 10 % (v/v-1) H2 + 90% (v/v-1) Ar was used as purge gas, increasing the atomization efficiency, the graphite tube and the tungsten platform lifetime. The use of 10 µg de (NH4)2HPO4 as chemical modifier was imperative for the determination of barium in drinking water and seawater. After the optimization, the detection limit was 3.5+/-0.3 µg L-1 and the characteristic mass was 2.1 pg. By using the tungsten platform modified with rhodium it was possible to obtain a transient absorbance signal at 2400 oC atomization temperature, with residence time of 0.5 s, against 2600 oC atomization temperature in graphite tube platform, with residence time of 15 s. The lifetimes of the tungsten platform modified with rhodium and the graphite tube were 200 and 750 heating cycles, respectively.
2

Explorando a espectrometria de absorção atômica com atomização eletrotérmica e amostragem direta em superfície metálica para a determinação de bário / Feasibility to use metalic platform to the graphite tube of the electrothermal atomic absorption spectrometry for barium determination

Daniela de Santi Scatamachia 17 March 2006 (has links)
A eficiência de atomização do bário, em superfície grafítica, é fortemente afetada pela formação de espécies refratárias, como carbetos e óxidos. Várias tentativas vêm sendo propostas no sentido de melhorar o limite de detecção do bário em espectrometria de absorção atômica com forno de grafite. Nesse sentido, o presente trabalho teve como objetivo estudar a viabilidade de se utilizar uma plataforma de tungstênio adaptada ao tubo de grafite do espectrômetro de absorção atômica, visando melhorar a eficiência de atomização do bário bem como a sua determinação em petróleo, óleos lubrificantes, água do mar e água mineral. O sistema proposto constituiu-se de uma plataforma de tungstênio com superfície modificada eletroliticamente com ródio, adaptada a um tubo de grafite com parede interna modificada com irídio. A mistura de 10% (v/v-1) H2 + 90% (v/v-1) Ar como gás de purga aumentou a eficiência de atomização, o tempo de vida do tubo de grafite e da plataforma. O uso de 10 µg de (NH4)2HPO4 como modificador químico foi indispensável para a determinação de bário em água mineral e de mar. O limite de detecção foi de 3,5+/-0,3 µg L-1 e a massa característica de 2,1 pg. Com a plataforma de tungstênio modificada com ródio foi possível gerar um sinal transiente de absorbância com temperatura de atomização de 2400 oC, com tempo de residência de, aproximadamente, 0,5 s, contra uma temperatura de atomização de 2600 oC para o forno de grafite, com tempo de residência de 15 s. A vida útil da plataforma de tungstênio, modificada com ródio, e do tubo de grafite foram, respectivamente, 200 e 750 ciclos de aquecimento. / The atomization efficiency of barium in graphite furnace is strongly affected by the refractory species formation, such as, carbides and oxides. Several attempts have been done to overcome these drawbacks and to improve the sensitivity of barium in electrothermal atomic absorption spectrometry. Thus the aim of the present work was to propose a tungsten platform inserted into the graphite tube of the atomic absorption spectrometer for the determination of barium in petrol, lubrificating oil, drinking water and seawater. The proposed system consisted of a tungsten platform electrolitically modified with rhodium and a graphite tube with the internal wall modified with iridium. The mixture of 10 % (v/v-1) H2 + 90% (v/v-1) Ar was used as purge gas, increasing the atomization efficiency, the graphite tube and the tungsten platform lifetime. The use of 10 µg de (NH4)2HPO4 as chemical modifier was imperative for the determination of barium in drinking water and seawater. After the optimization, the detection limit was 3.5+/-0.3 µg L-1 and the characteristic mass was 2.1 pg. By using the tungsten platform modified with rhodium it was possible to obtain a transient absorbance signal at 2400 oC atomization temperature, with residence time of 0.5 s, against 2600 oC atomization temperature in graphite tube platform, with residence time of 15 s. The lifetimes of the tungsten platform modified with rhodium and the graphite tube were 200 and 750 heating cycles, respectively.
3

Quantificação de metais potencialmente tóxicos em mexilhão dourado (Limnoperna fortunei) por espectrometria de absorção atômica com fonte contínua e alta resolução empregando amostragem direta de sólidos / Quantification of potentially toxic metals in golden mussel (Limnoperna fortunei) with high resolution continnun source atomic absorption spectrometry using direct solid sample

Silva, Ana Caroline Soncin [UNESP] 29 March 2016 (has links)
Submitted by ANA CAROLINE SONCIN DA SILVA null (col_zinha@hotmail.com) on 2016-05-21T03:08:22Z No. of bitstreams: 1 Dissertação_Mestrado.pdf: 2242269 bytes, checksum: d87570a91a3ceb91484c2ca2920007e1 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-24T13:46:03Z (GMT) No. of bitstreams: 1 silva_acs_me_ilha.pdf: 2242269 bytes, checksum: d87570a91a3ceb91484c2ca2920007e1 (MD5) / Made available in DSpace on 2016-05-24T13:46:03Z (GMT). No. of bitstreams: 1 silva_acs_me_ilha.pdf: 2242269 bytes, checksum: d87570a91a3ceb91484c2ca2920007e1 (MD5) Previous issue date: 2016-03-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O mexilhão dourado (Limnoperna fortunei) tem provocado transtornos ambientais e econômicos nas localidades onde foi introduzido. Dessa forma, o uso do seu resíduo moído como reparador da defasagem de nutrientes e de acidez em solos agrícolas pode vir a ser uma boa aplicação para esse molusco bioinvasor. Entretanto, apesar dessa ação reparadora, é necessária uma averiguação prévia da ausência de elementos potencialmente tóxicos no resíduo. Neste contexto, o presente trabalho foi realizado com o intuito de quantificar, em amostras do Limnoperna fortunei, os elementos chumbo, cádmio, alumínio, ferro e manganês, os quais dependo de suas quantidades podem ser tóxicos aos vegetais e aos demais seres vivos ao longo da cadeia alimentar. Para quantificação desses analitos foi utilizada a Espectrometria de absorção atômica com fonte contínua e de alta resolução. Foram desenvolvidos e otimizados programas de aquecimento para a determinação dos elementos traço chumbo e cádmio, empregando amostragem direta de sólidos e atomização com forno de grafite. A determinação direta de chumbo só foi possível com a utilização da calibração com o material de referência certificado para tecido de mexilhão (Mussel Tissue – 2976), empregando 5 µL da mistura 0,1% (m/v) Pd (NO3)2 + 0,05% (m/v) Mg (NO3)2 em presença de 0,05% (m/v) de Triton X-100 como modificador químico. As temperaturas de pirólise e atomização foram 1000°C e 2200°C, respectivamente. O estudo de massa permitiu a utilização de massas de amostras dentro da faixa de 0,150 a 0,850 mg. Para o cádmio só foi realizada calibração com solução padrão 12,5 µg/L, também com o uso de 5 µL do modificador químico Pd+Mg. Assim, foram alcançadas temperaturas de pirólise de 900 °C e de 1600 °C para a atomização. O estudo de massa precisou ser desenvolvido com uma das amostras coletadas e demonstrou que puderam ser usadas, para as quantificações, massas próximas a 0,250 mg. Os limites de detecção e quantificação foram, nessa ordem, 0,009 mg/kg e 0,03 mg/kg para o chumbo, e 0,0004 e 0,001 mg/kg para o cádmio. No caso dos elementos alumínio, ferro e manganês, as quantificações foram realizadas utilizando a atomização com chama. Os limites de detecção e quantificação foram, respectivamente, 0,15 mg/kg e 0,50 mg/kg para o alumínio, 0,050 mg/kg e 0,15 mg/kg para o ferro, e 0,00067 mg/kg e 0,0023 mg/kg para o manganês. Os resultados para todos os elementos quantificados nesse estudo apresentaram concordância de 95% com o test-t (Student) não pareado, o que valida e viabiliza os métodos desenvolvidos para as quantificações de chumbo e cádmio, bem como comprova a exatidão dos demais resultados obtidos. Portanto, as técnicas analíticas selecionadas foram eficientes para as quantificações dos elementos desejados no resíduo moído desse mexilhão dourado. / The golden mussel (Limnoperna fortunei) has caused environmental and economic disruption in the locations where it was introduced. Thus, the use of their ground waste as repairer of the gap of nutrients and acidity in soils may prove to be a good application for this mollusk bio invader. However, despite of this remedial action, a prior test of the absence of potentially toxic elements in the residue is required. In this context, the present study was performed in order to quantify, in samples of the Limnoperna fortunei, the elements lead, cadmium, aluminum, iron and manganese, which depending on their quantities they can be toxic to plants and other living beings throughout the food chain. To quantify these analytes was used high-resolution continuum source atomic absorption spectrometry. Heating programs were developed and optimized for the determination of lead and cadmium trace elements, using direct solid and graphite furnace atomization. The direct determination of lead was only possible with the use of calibration with certified reference material for mussel tissue (Mussel Tissue - 2976), using 5 uL of the mixture 0.1% (m/v) Pd (NO3)2 + 0.05% (w/v) Mg (NO3)2 in the presence of 0.05% (w/v) Triton X-100 as a chemical modifier. The temperatures of pyrolysis and atomization were 1000 ° C and 2200 ° C respectively. The mass study allowed the use of samples of mass within the range of 0.150 to 0.850 mg. For cadmium it was only performed calibration with standard 12.5 g/L solution, also using 5 uL chemical modifier Pd + Mg. Thus, pyrolysis temperatures were reached 900 ° C and 1600 ° C for atomization. The mass study needed to be developed with one of the samples collected and it showed that they could be used for the measurements, masses close to 0,250 mg. The limits of detection and quantification were, in this order, 0.009 mg/kg and 0.03 mg/kg to lead, and 0.0004 and 0.001 mg/kg to cadmium. In case of the elements aluminum, iron and manganese, the measurements were carried out using atomization with a flame. The limits of detection and quantification were, respectively, 0.15 mg/kg and 0.50 mg/kg to aluminum, 0.050 mg/kg and 0.15 mg/kg for iron, and 0.00067 mg/kg and 0.0023 mg/kg to manganese. The results for all quantified elements of this study showed agreement of 95% with the t-test (Student) unpaired, which validates and enables the methods developed for lead and cadmium quantifications and proves the accuracy of the other results. Therefore, the selected analytical techniques were efficient to the quantifications of the desired elements in the ground waste this golden mussel.
4

Determinação de Co, Mo, Ni e V em material vegetal e solo por espectrometria de absorção atômica com fonte contínua e de alta resolução em forno de grafite empregando amostragem direta de sólidos / Determination of Co, Mo, Ni and V in plant material and soil by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sample analysis

Babos, Diêgo Victor de [UNESP] 18 July 2016 (has links)
Submitted by DIÊGO VICTOR DE BABOS null (diegobabos@hotmail.com) on 2016-08-08T23:38:08Z No. of bitstreams: 1 Dissertação Diêgo Babos.pdf: 1989792 bytes, checksum: 30376a94b5f5cac12b35744978cd6cc7 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-11T14:14:27Z (GMT) No. of bitstreams: 1 babos_dv_me_araiq_par.pdf: 1035449 bytes, checksum: 4a4c8a9a99f92024681ea27985b94b19 (MD5) / Made available in DSpace on 2016-08-11T14:14:27Z (GMT). No. of bitstreams: 1 babos_dv_me_araiq_par.pdf: 1035449 bytes, checksum: 4a4c8a9a99f92024681ea27985b94b19 (MD5) Previous issue date: 2016-07-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Avaliou-se a amostragem direta de sólidos como base de métodos analíticos simples, rápidos e mais limpos para determinar Co, Mo, Ni e V em tecido vegetal e solo empregando a espectrometria de absorção atômica de alta resolução com fonte contínua. Esta técnica foi escolhida devido as suas características peculiares, especialmente a elevada capacidade de correção de fundo. Na determinação de cobalto em material vegetal, a sobreposição espectral de SiO(g) na linha 240,725 nm do Co foi corrigida pelo método dos mínimos quadrados. Curvas de calibração (0–540 pg) com bons coeficientes de correlação lineares (R 0,9993) foram obtidas com padrões sólidos. O limite de detecção (LOD) foi 3 pg Co. Na determinação simultânea de Mo e Ni em material vegetal, empregou-se Co como padrão interno para Ni. Curvas de calibração (0,8-50 ng Ni; 0-0,33 ng Mo) lineares (R 0,9937) foram obtidas com padrões aquosos sem modificador químico. Os LODs foram 0,018 ng Mo e 0,025 ng Ni. A padronização interna aumentou a precisão das medidas para Ni de 62-135% para 94-105%. Vanádio e Co foram determinados em solos empregando NH4F como modificador. As calibrações, com padrões aquosos para V (0-40 ng), e por compatibilização de matriz para Co (0-5,0 ng), forneceram R 0,9979. Os LODs foram 0,044 ng Co e 0,43 ng V. Na determinação de Mo e Ni em solo, o modificador Mg(NO3)2 foi utilizado apenas para Ni. As curvas de calibração aquosas (0-500 ng Ni; 0-0,54 ng Mo) forneceram R 0,9953. Na determinação do Ni foi monitorado o tripleto em 341,377 nm, 341,347 nm e 341,394 nm, permitindo determinar Ni em ampla faixa de concentração. Os LODs foram 0,0082 ng Mo (313,259 nm), 0,021 ng Ni (341,477 nm),1,8 ng Ni (341,347 nm). A exatidão dos métodos foi avaliada via análise de materiais de referência certificados de solos e plantas. De uma forma geral, os resultados obtidos foram concordantes com os valores certificados ao nível de confiança de 95%. / High-resolution continuum source atomic absorption spectrometry with direct solid sampling was employed for the development of simple, fast and clean analytical methods for Co, Mo, Ni and V determination in soil and plant materials. The technique has as main advantages the efficiency to correct background absorption. For cobalt determination in plant material, a spectral overlap of SiO molecular absorption in Co line was corrected by using least squares background correction method. Calibration curves (0-540 pg) with correlation coefficients higher of 0.9993 were obtained with solid standards. The limit of detection was of 3 pg Co. For simultaneous determination of Mo and Ni in plant material Co was employed as internal standard for Ni. Calibration curves (0.8-50 ng Ni; 0-0.33 ng Mo) with correlation coefficients higher of 0.9937 were obtained with aqueous standards without chemical modifier. The LODs were 0.025 and 0.018 ng for Mo and Ni, respectively. The internal standardization increased the accuracy of Ni determinations from 62-135% to 94-105%. For V and Co determinations in soils the NH4F was used as chemical modifier. The calibration with aqueous standards for V (0-40 ng), and compatibility matrix for Co (0-5.0 ng), provided linear correlation coefficients better of 0.9979. The LODs were 0.044 and 0.43 ng for Co and V, respectively. For Mo and Ni determination in soil the Mg(NO3)2 was used as chemical modifier for Ni. The aqueous calibration curves (0-500 ng Ni; 0-0.54 ng Mo) provided linear correlation coefficients higher of 0.9953. For Ni determination were used the triplet lines at 341.377 nm, 341.347 nm and 341.394 nm, allowing the determination of Ni in wide concentration range. The calculated LODs were 0.0082 ng Mo (313.259 nm), 0.021 ng Ni (341.477 nm), 1.8 ng Ni (341.347 nm). The accuracy of the proposed methods was assessed by analysis of certified reference materials of soils and plants. In general, the results were in agreement with the certified values at 95% confidence level (t-test).
5

Quantificação de metais potencialmente tóxicos em mexilhão dourado (Limnoperna fortunei) por espectrometria de absorção atômica com fonte contínua e alta resolução empregando amostragem direta de sólidos /

Silva, Ana Caroline Soncin January 2016 (has links)
Orientador: Mirian Cristina dos Santos / Resumo: O mexilhão dourado (Limnoperna fortunei) tem provocado transtornos ambientais e econômicos nas localidades onde foi introduzido. Dessa forma, o uso do seu resíduo moído como reparador da defasagem de nutrientes e de acidez em solos agrícolas pode vir a ser uma boa aplicação para esse molusco bioinvasor. Entretanto, apesar dessa ação reparadora, é necessária uma averiguação prévia da ausência de elementos potencialmente tóxicos no resíduo. Neste contexto, o presente trabalho foi realizado com o intuito de quantificar, em amostras do Limnoperna fortunei, os elementos chumbo, cádmio, alumínio, ferro e manganês, os quais dependo de suas quantidades podem ser tóxicos aos vegetais e aos demais seres vivos ao longo da cadeia alimentar. Para quantificação desses analitos foi utilizada a Espectrometria de absorção atômica com fonte contínua e de alta resolução. Foram desenvolvidos e otimizados programas de aquecimento para a determinação dos elementos traço chumbo e cádmio, empregando amostragem direta de sólidos e atomização com forno de grafite. A determinação direta de chumbo só foi possível com a utilização da calibração com o material de referência certificado para tecido de mexilhão (Mussel Tissue – 2976), empregando 5 µL da mistura 0,1% (m/v) Pd (NO3)2 + 0,05% (m/v) Mg (NO3)2 em presença de 0,05% (m/v) de Triton X-100 como modificador químico. As temperaturas de pirólise e atomização foram 1000°C e 2200°C, respectivamente. O estudo de massa permitiu a utilização de massas de am... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The golden mussel (Limnoperna fortunei) has caused environmental and economic disruption in the locations where it was introduced. Thus, the use of their ground waste as repairer of the gap of nutrients and acidity in soils may prove to be a good application for this mollusk bio invader. However, despite of this remedial action, a prior test of the absence of potentially toxic elements in the residue is required. In this context, the present study was performed in order to quantify, in samples of the Limnoperna fortunei, the elements lead, cadmium, aluminum, iron and manganese, which depending on their quantities they can be toxic to plants and other living beings throughout the food chain. To quantify these analytes was used high-resolution continuum source atomic absorption spectrometry. Heating programs were developed and optimized for the determination of lead and cadmium trace elements, using direct solid and graphite furnace atomization. The direct determination of lead was only possible with the use of calibration with certified reference material for mussel tissue (Mussel Tissue - 2976), using 5 uL of the mixture 0.1% (m/v) Pd (NO3)2 + 0.05% (w/v) Mg (NO3)2 in the presence of 0.05% (w/v) Triton X-100 as a chemical modifier. The temperatures of pyrolysis and atomization were 1000 ° C and 2200 ° C respectively. The mass study allowed the use of samples of mass within the range of 0.150 to 0.850 mg. For cadmium it was only performed calibration with standard 12.5 g/L sol... (Complete abstract click electronic access below) / Mestre
6

Aplicação e desenvolvimento de estratégias analíticas para determinação de minerais em fórmulas infantis a base de cereais empregando ICP OES e HR-CS ET AAS

Silva, Arlene Santos 14 April 2014 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-02T12:43:55Z No. of bitstreams: 1 Arlene Silva - Dissertação de Mestrado.pdf: 1371818 bytes, checksum: 8ece52833590ece6ea60d0a4a6b20ee4 (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-12T15:29:29Z (GMT) No. of bitstreams: 1 Arlene Silva - Dissertação de Mestrado.pdf: 1371818 bytes, checksum: 8ece52833590ece6ea60d0a4a6b20ee4 (MD5) / Made available in DSpace on 2016-05-12T15:29:30Z (GMT). No. of bitstreams: 1 Arlene Silva - Dissertação de Mestrado.pdf: 1371818 bytes, checksum: 8ece52833590ece6ea60d0a4a6b20ee4 (MD5) / CAPES / A ingestão de nutrientes minerais é fundamental ao desenvolvimento físico e mental das crianças e à manutenção da saúde dos indivíduos em todas as faixas etárias. Motivo pelo qual as agências de regulação da saúde e assistência humana, ANVISA (Agência Nacional de Vigilância Sanitária) e OMS (Organização Mundial de Saúde) estabeleceram o IDR (ingestão diária recomendada) de nutrientes, vitaminas e minerais. Nos primeiros seis meses de vida, a incorporação destes nutrientes via aleitamento materno na dieta infantil é suficiente segundo estes órgãos. A partir desta fase, sugere-se a complementação da nutrição destes indivíduos com alimentos de origem animal e vegetal. As fórmulas infantis, utilizadas para este fim, merecem especial atenção no que tange ao teor dos nutrientes minerais. Assim, o presente trabalho tem como objetivo avaliar o teor de minerais, bem como sua biodisponibilidade, em fórmulas infantis à base de cereais e desenvolver um método de amostragem direta sólidos para determinação de cromo nestas amostras. Para a determinação dos nutrientes aplicou-se um método de digestão por via úmida em bloco digestor, com dedo frio, utilizando ácido nítrico e peróxido de hidrogênio como oxidantes. Com o objetivo de classificar as amostras quanto ao teor de minerais realizou-se a análise multivariada dos dados. Para o estudo da biodisponibilidade de nutrientes minerais nas amostras foi aplicado um método de extração usando uma solução gástrica de HCl e pepsina. A quantificação dos macro e microelementos nas amostras avaliadas por ambos os métodos, foi realizada utilizando a espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Os nutrientes foram avaliados a nível de mg g-1 e as faixas de concentrações encontradas foram: Ca (0,05 ± 0,03 a 5,62 ± 0,13);K (0,26 ± 0,09 a 4,36 ± 0,28); Mg (0,041 ± 0,006 a 1,515 ± 0,510);Na (0,10 ± 0,05 a 4,71 ± 0,098); P (0,79 ± 0,07 a 6,63 ± 0,54); Fe (0,184 ± 0,007 a 0,536 ± 0,074); Mn (0,0206 ± 0,0007 a 0,0663 ± 0,0088); Se (0,0130 ± 0,0069 a 0,0168 ± 0,0010); e Zn (0,026 ± 0,007 a 0,249 ± 0,231). A análise multivariada dos resultados permitiu a classificar as amostras segundo a sua composição e avaliar o teor nutricional das mesmas. Os resultados obtidos na extração de nutrientes minerais com a solução gástrica apontaram para uma maior biodisponibilidade dos elementos Ca, K e Mg para alimentos à base de aveia, percentuais de extração 72, 86 e 81 %, respectivamente; 35 % de Fe na amostra a base de multicereais; e 56 % de Zn e 46 % de P para amostra a base de milho. O desenvolvimento do método para determinação de cromo em fórmulas infantis a base de cereais foi realizado utilizando a espectrometria de absorção atômica com fonte continua de alta resolução com atomização eletrotérmica (HR-CS ET AAS) e amostragem direta de sólidos. Os limites de detecção e quantificação encontrados para o método foram:3,74 e 12, 46 ng g-1, respectivamente. A massa característica encontrada para o método foi 1,2 pg e RSD 10,76 %. O método proposto possui boa precisão e exatidão, para o CRM de folha de tomate NIST 1573a, na determinação de Cr em fórmulas infantis a base de cereais. As concentrações de Cr variaram de 33,9 a 58,1 ng g-1 (n = 3). / The intake of nutrients is essential to physical and mental development of children and the maintenance of the health of individuals in all age. Therefore, the regulatory agencies of health and human assistance, ANVISA (National Health Surveillance Agency) and WHO (World Health Organization) established the IDR (recommended daily intake) of nutrients, vitamins and minerals. In the first six months of life, these nutrients incorporation through breastfeeding in children's diet is sufficient according to these organs. From this stage, it is suggested to complement the nutrition of these individuals with animal and plant foods. Infant formula, used for this purpose, need special attention with regard to the content of nutrients. Thus, this study aims to evaluate the mineral content as well as its bioavailability, infant formulas from cereals and develop a method of solid direct sampling for determination of chromium in these samples. To determine the nutrients applied a method of humid digestion in digester block, cold finger, using nitric acid and hydrogen peroxide as oxidizing. In order to classify the samples in mineral content was held on multivariate data analysis. To study the bioavailability of nutrients in the samples was applied to a method of extracting using a gastric solution of HCl and pepsin. The quantification of macro- and microelements in samples measured in both methods was performed by optical emission spectrometry with inductively coupled plasma (ICP OES). Nutrients were evaluated in terms of mg g-1, and the concentration ranges found were: Ca (0.05 ± 0.03 to 5.62 ± 0.13), K (0.26 ± 0.09 to 4, 36 ± 0.28); Mg (0.041 ± 0.006 to 1.515 ± 0.510), Na (0.10 ± 0.05 to 4.71 ± 0.098); P (0.79 ± 0.07 to 6.63 ± 0.54); Fe (0.184 ± 0.007 to 0.536 ± 0.074); Mn (0.0206 ± 0.0007 to 0.0663 ± 0.0088); Se (0.0130 ± 0.0069-.0168 ± 0.0010); and Zn (0.026 ± 0.007 to 0.249 ± 0.231). Multivariate analysis of the results allowed to classify the samples according to their composition and evaluate the nutritional content of them. The results obtained in the extraction of mineral nutrients to the gastric solution showed an increased bioavailability of Ca, K and Mg oat based foods, percentage extraction 72, 86 and 81%, respectively; 35% Fe in the sample multicereais base; and 56% Zn and 46% P for the sample based on corn. The development of the method for determination of chromium in infant formulas the cereal was performed using atomic absorption spectrometry with continuous source of high resolution with electrothermal atomization (HR-CS ET AAS) and direct solid. The limits of detection and quantification for the method found were 3.74 and 12, 46 ng g-1, respectively. The characteristic mass found for method was 1.2 pg and RSD 10.76%. The proposed method showed good precision and accuracy, for tomato leaf CRM NIST 1573a, in determining Cr infant formulas cereal. The chromium concentrations varied from 33.9 to 58.1 ng g-1 (n = 3).
7

Determinação de Cl, I e Hg de forma direta em amostras diversas por espectrometria de absorção atômica e molecular de alta resolução com fonte contínua em forno de grafite / Determination of CI, I, and Hg directly in different samples by high-resolution continuum source atomic and molecular absorption spectrometry in graphite furnace

Guarda, Ananda Fagundes 11 January 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Three analytical methods were developed for the determination of chlorine, iodine and mercury in solid and liquid samples, directly by high resolution continuum source atomic and molecular absorption spectrometry in graphite furnace. The first method objected the determination of chlorine in solid and slurry samples of different natures and chlorine contents (CRM 81002b human hair, SRM 1568b rice flour, ERM EC681 polyethylene, CRM BCR 460 coal, SRM 2692c bituminous coal, SRM 1575 sheet Of pine, CRM 686-1 iron oxide, SRM 1549 powdered milk) through the molecular formation of CaCl. The results were compared with those already available for the SrCl molecule and were superior, especially in samples with a high calcium content. The limit of detection and quantification obtained for the two molecular absorption lines of CaCl were 2.6 and 8.7 ng (620.862 nm) and 14.2 and 61.6 ng (377.501 nm), respectively. The iodine determination was performed through the formation of the SrI molecule in two samples of medicines containing iodine. The accuracy of the method was proved by comparative analysis by inductively coupled plasma mass spectrometry. The results obtained were higher compared to the existing BaI molecule that does not provide direct determination in solids. The limit of detection and quantification obtained were 0.035 and 0.117 μg, respectively. Finally, an analytical method for the determination of mercury in blood samples (SERONORM® LEVEL III and II) and urine (SERONORM®, Clincheck Control level I and II batch 432 and level II batch 923) were developed, directly, using gold nanoparticles. The method was compared to the existing method that uses potassium permanganate as oxidizing agent. The limit of detection and quantification obtained were 0.057 and 0.190 ng, respectively. / Foram desenvolvidos três métodos analíticos para a determinação de cloro, iodo e mercúrio em amostras sólidas e líquidas, de forma direta por espectrometria de absorção atômica e molecular de alta resolução com fonte contínua em forno de grafite. O primeiro método objetivou a determinação de cloro em amostras sólidas e em suspensão de diferentes naturezas e teores de cloro (CRM 81002b cabelo humano, SRM 1568b farinha de arroz, ERM EC681 polietileno, CRM BCR 460 carvão, SRM 2692c carvão betuminoso, SRM 1575 folha de pinheiro, CRM 686-1 óxido de ferro, SEM 1549 leite em pó), através da formação molecular de CaCl. Os resultados foram comparados com os já existentes para a molécula de SrCl e mostraram-se superiores, especialmente em amostras com alto teor de cálcio. O limite de detecção e quantificação obtidos para as duas linhas de absorção molecular de CaCl foram de 2,6 e 8,7 ng (620,862 nm) e 14,2 e 61,6 ng (377,501 nm), respectivamente. Já a determinação de iodo realizou-se através da formação da molécula de SrI, em duas amostras de medicamentos contendo iodo. A exatidão do método foi comprovada através de analise comparativa por espectrometria de massas com plasma acoplado indutivamente. Os resultados obtidos se mostraram superiores em comparação com molécula já existente BaI que não proporciona a determinação direta em sólidos. O limite de detecção e quantificação obtidos foram de 0,035 e 0,117 μg, respectivamente. Por fim, foi desenvolvido um método analítico para a determinação de mercúrio em amostras de sangue (SERONORM® LEVEL III e II) e urina (SERONORM®, Clincheck Control nível I e II lote 432 e nível II lote 923) certificadas, de forma direta, utilizando nanopartículas de ouro. O método foi comparado ao método já existente que utiliza permanganato de potássio como agente oxidante. O limite de detecção e quantificação obtidos foram de 0,057 e 0,190 ng, respectivamente.

Page generated in 0.0483 seconds