• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 206
  • 26
  • 25
  • 25
  • 25
  • 19
  • 6
  • 5
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 224
  • 224
  • 224
  • 134
  • 111
  • 110
  • 59
  • 58
  • 45
  • 44
  • 43
  • 42
  • 35
  • 32
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Sistemas adesivos autocondicionantes : estudo micromecânico da interface de união através do método dos elementos finitos tridimensional /

Anchieta, Rodolfo Bruniera. January 2010 (has links)
Resumo: Introdução: Embora os sistemas adesivos autocondicionantes se caracterizem por desmineralizar e infiltrar a dentina simultaneamente, a presença de dentina alterada abaixo da camada híbrida tem sido reportada, sugerindo comportamento mecânico distinto. Proposição: Avaliar por meio do método dos elementos finitos tridimensional a influência da espessura da dentina parcialmente alterada no comportamento micromecânico de dois sistemas adesivos autocondicionantes. Materiais e Métodos: Foram elaborados 5 micro-modelos (M) simulando a interface dentina/adesivo (d/a) (82x41x41 μm), sendo: M1-representação da interface d/a baseada em sistema adesivo convencional de 2 passos; M2-representação de um sistema adesivo autocondicionante de 2 passos. Nos M3, M4 e M5 representação de um sistema adesivo autocondicionante de 1 passo, variando a espessura da camada de dentina parcialmente alterada em 0, 1,5 e 3 μm, respectivamente. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos. A base de todos os modelos foi fixada nos eixos x, y e z, sendo aplicado um carregamento em tração (90º; 0,03 N) na face superior da resina composta. A análise numérica foi realizada para a obtenção da tensão principal máxima ( max). Resultados: o pico da max (MPa) foi encontrada no M5 (79,5), seguido do M4 (78,0) e do M3 (70). O topo dos tags foi o local mais solicitado em todos os modelos. Conclusão: O aumento da espessura da dentina parcialmente alterada aumentou a tensão na interface d/a; a ausência desta camada contribuiu para a menor concentração de tensão; o topo dos tags foi o local mais exigido na interface d/a. / Abstract: Introduction: Although the self-etching adhesives are characterized by etching and infiltrating simultaneously the dentin, the presence of an altered dentin layer has been showed by literature, which might show specific mechanical behavior. Proposition: To evaluate through 3-D finite element analysis the influence of the partially altered dentin thickness on the micromechanical behavior of the self-etch adhesives. Materials and Methods: 5 micro-models (M) were developed for simulating the dentin/adhesive (d/a) interface (82x41x41 μm): M1-representation of the d/a interface based on 2 steps conventional adhesive system; M2-d/a interface based on 2 steps self-etch adhesive system M3, M4 and M5 - d/a interface based on all-in-one adhesive system, varying the thickness of the partially altered dentin (0, 1.5 and 3 μm, respectively). All the models were considered isotropic, homogeneous and lineally elastic. The bottom of all the models were constrained in the axes x, y and z. A tensile load (90o; 0.03N) was applied on the top of the composite resin. The numeric analysis was accomplished, being obtained the maximum principal stress ( max). Results: The pick of max (MPa) was found in M5 (79.5), followed by M4 (78.0) and M3 (70). The top of the resin tags was the most requested place in all models. Conclusion: The increase of the partially altered dentin thickness raised the max in the d/a interface; the absence of this layer contributed to the smallest tension concentration; the top of the tags showed higher stress concentration. / Orientador: Eduardo Passos Rocha / Coorientador: Renato Herman Sundfeld / Banca: Paulo Henrique dos Santos / Banca: André Figueiredo Reis / Mestre
102

Análise bidimensional de tensões em implante de nióbio e titânio pelo método dos elementos finitos

Souza, Leonardo Rodrigues de 28 June 2006 (has links)
The biomechanical of implants play an important hole in osseointegration. The finite element method provides a biomechanical study based on numerical evaluation from mathematical models. In this work, the von Mises stress from models with niobium implant was compared with titanium implant. A twodimensional model with screw type implant (4.1 x 10 mm) and cicatrizador (4.5 x 3 mm) in cortical and cancellous bone tissue was used. Force of 100 N was applied axially at the center surface of the cicatrizador. The materials on this analysis were assumed to be homogeneous, isotropic and linearly elastic. The analyzed stress was obtained from previously nodes selected on bone-implant contact, on implant, cortical and cancellous bone tissue inside. The results based on compared analysis between models with niobium implant and titanium showed a similar distribution of stress on implant, cortical and cancellous bone tissue inside, and bone-implant contact. / A biomecânica dos implantes tem papel fundamental na osseointegração. O método dos elementos finitos proporciona o estudo da biomecânica baseada na avaliação numérica de modelos matemáticos. Neste trabalho avaliou-se comparativamente as tensões de von Mises geradas em modelo com implante de nióbio e em modelo com implante de titânio. Utilizou-se um modelo bidimensional com implante cilíndrico rosqueável de 4.1 x 10 mm e cicatrizador de 4.5 x 3 mm em tecido ósseo cortical e trabecular. Uma carga axial de 100 N foi aplicada na superfície central do cicatrizador. Os materiais envolvidos nesta análise foram considerados homogêneos, isotrópicos e linearmente elásticos. As tensões avaliadas foram obtidas de Nós previamente selecionados no contato osso-implante, no interior do implante, tecido ósseo cortical e trabecular. Os resultados baseados na análise comparativa entre os modelos com implante de nióbio e de titânio demonstraram uma distribuição similar das tensões no interior do implante, tecido ósseo cortical e trabecular, e no contato osso-implante. / Mestre em Odontologia
103

Análise das tensões geradas por prótese obturadora maxilar implanto-retida por meio da análise de elementos finitos / Avaliation of stresses generated by the maxillary obturator prosthesis implant-retained by the finite element analysis

Andréa Alves de Sousa 07 August 2012 (has links)
Neste estudo avaliou-se o comportamento biomecânico de próteses obturadoras maxilares Classe Ib, II e III de Okay retidas por implantes, observando as tensões geradas no tecido ósseo e gengivo-mucoso maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir de uma tomografia computadorizada de um indivíduo adulto. Utilizou-se o programa Rhinoceros® versão 4.0 SR9 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes e UCLAS. Os implantes foram posicionados de acordo com cada modelo: Modelo 1 (Classe Ib de Okay): 6 implantes posicionados em regiões de caninos e incisivos laterais bilateralmente e em região de segundo premolar e primeiro molar esquerdos onde foram utilizados 4 clipes para o sistema de retenção barra/clipe; Modelo 2 (Classe II de Okay): 4 implantes posicionados em região de canino, incisivo lateral, segundo premolar e primeiro molar esquerdos, com 3 clipes; Modelo 3 (Classe III de Okay): 2 implantes posicionados em região de segundo premolar e primeiro molar esquerdos, com 2 clipes. A malha de elementos finitos foi gerada pelo programa Ansys®, tendo sido aplicada uma força de 80 N na plataforma oclusal, e de 35 N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de tensão máxima principal, com valores quantitativos expressos em MPa. O deslocamento da prótese obturadora na região sem suporte ósseo aumentou em função da diminuição da área de suporte ósseo, do número de implantes e de clipes; a mucosa gengival, o osso cortical e o osso medular sofreram tensões de tração e de compressão que aumentaram em função da diminuição da área de suporte ósseo, do número de implantes e de clipes. Concluiu-se que quanto maior a perda da área de suporte ósseo em uma maxilectomia, maiores serão as forças de tensão e de compressão geradas pelo sistema de retenção barra/clipe nos tecidos remanescentes e maior será a tendência para o deslocamento da prótese. / Patients submitted to maxillectomy due to oral cancer shall be rehabilitated by means of obturator prosthesis in order to achieve a better quality of life. This study evaluated the biomechanics of implant-retained obturator prostheses analyzing the stress on maxillary osseous and gingivo-mucosal tissues. Finite elements analysis was developed using a 3D digital model based on a computed tomography of an adult man. Files were processed by Software Rhinoceros®, v4.0 SR9 and generated a maxillary BioCAD 3D model, which incorporated the CAD models of the implants and UCLAS. The implants were located considering: Model 1 (Okay Class Ib) - 6 implants in the areas of canines and lateral incisors and in the areas of left second premolar and molar, retention system bar/4 clips; Model 2 (Okay Class II ) - 4 implants located in the areas of canine, lateral incisor, left second premolar and first molar, retention system bar/3 clips; Model 3 (Okay Classe III) - 2 implants inserted in the left second premolar and first molar, retention system bar/2clips. The finite elements mesh was generate using Software Ansys®. A force of 80 N was applied to the occlusal platform and, at the same time, a force of 35 N was applied to the incisal platform of the obturator prosthesis. Results considered a qualitative analysis, based on the scale of maximum principal stress, and a quantitative analysis, when values were expressed in MPa. The dislodgement of the obturator prosthesis in the area with no osseous support increases as the area of the osseous support, the number of implants and clips diminish; the tensile and compressive stress in the gingival mucosa, the cortical and the alveolar bone increase as the osseous support, the number of implants and of clips diminish. The larger the area without osseous support, the higher the tensile and compressive stress in the remaining tissues and greater the displacement of the prosthesis.
104

Braquete ortodôntico com gancho alongado verticalmente e semi-flexível

Duque, Paulo Henrique da Rocha 08 August 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-11-06T13:37:53Z No. of bitstreams: 1 paulohenriquedarochaduque.pdf: 1698700 bytes, checksum: 10981084ef7d6b6c2e58c081df3f2f4f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-11-09T14:24:07Z (GMT) No. of bitstreams: 1 paulohenriquedarochaduque.pdf: 1698700 bytes, checksum: 10981084ef7d6b6c2e58c081df3f2f4f (MD5) / Made available in DSpace on 2017-11-09T14:24:08Z (GMT). No. of bitstreams: 1 paulohenriquedarochaduque.pdf: 1698700 bytes, checksum: 10981084ef7d6b6c2e58c081df3f2f4f (MD5) Previous issue date: 2017-08-08 / Durante o tratamento ortodôntico é frequente que o profissional realize movimentos distais dos dentes. Uma forma eficiente para movimentar um dente sem que inclinações indesejadas aconteçam é aproximar as forças do centro de resistência dentário (CR). Não foi encontrado na literatura citações de bráquetes préfabricados com ganchos de altura que permitam que a força aplicada a eles passe pelo CR. Desenvolver um protótipo virtual de um acessório ortodôntico com o gancho alongado verticalmente e realizar testes através do Método de Elementos Finitos (MEF) para avaliar o comportamento biomecânico do dente, simulando três situações de exposição de forças: passando pelo CR, acima do CR e abaixo do CR. Foi desenvolvido um bráquete ortodôntico com uma extensão vertical de 15 mm de altura e 1 mm de diâmetro em sua aleta distal. Através do MEF foi realizada a simulação da aplicação de forças no sentido distal do canino utilizando o bráquete com o dispositivo criado. A criação do protótipo virtual para realização dos testes em MEF foi realizada com êxito. Observou-se que a tendência de deslocamento do canino obteve um maior movimento de corpo quando a força estava passando próximo ao CR. / During orthodontic treatment, the professional often performs distal movements of the teeth. An efficient way to move a tooth without undesired inclinations is to approach the forces of the center of tooth resistance (RC). We have not found in the literature quotes of prefabricated brackets with height hooks that allow the force applied to them to pass through the RC. The objective of the present study was to develop a virtual prototype of an orthodontic attachment with the hook vertically elongated and perform tests using the Finite Element Method (FEM) to evaluate the biomechanical behavior of the tooth, simulating three situations of force exposure: passing through the RC, above the RC and below the RC. An orthodontic bracket with a vertical extension of 15 mm in height and 1 mm in diameter was developed in its wings. Through the FEM, the simulation of the application of forces in the distal direction of the canine was performed using the bracket with the created device. The creation of the virtual prototype to perform the MEF tests was carried out successfully. It was observed that the movement tendency of the canine obtained a greater body movement when the force was passing near the RC.
105

Análise da distribuição de tensões do conjunto implante/prótese de implantes de zircônia na região periimplantar / Analysis of the distribution of deformations on the implant/prosthesis assembly of zirconium implants in the peri-implant region

Melody Analia Chase Diaz 26 February 2015 (has links)
Este estudo teve como objetivo analisar as tensões do osso periimplantar, analisando as forças axiais e oblíquas incidentes em um modelo 3D usando Método de Elementos Finitos (MEF) a partir de modelo experimental in vitro, que consistiu em: 1 implante Brånemark System MkIIIGroovde (3,75 mm de diâmetro, 13,0 mm de comprimento); 1 pilar multi-unit de 5mm de altura com parafuso de titânio e torque de 20Ncm; infraestrutura de cobalto-cromo revestida com cerâmica feldspática aparafusada com torque de 10 Ncm, e poliuretano simulando o osso. Para obter dados de deformação, extensômetros lineares elétricos (Strain Gauges) foram utilizados e os valores obtidos foram comparados com o MEF gerado a partir do escaneamento do modelo em Micro CT e reconstruído tridimensionalmente no software Simpleware. Uma vez construído o modelo do MEF, as propriedades mecânicas dos implantes de titânio foram substituídas pelas propriedades dos implantes de zircônia Y-TZP no programa ANSYS. Uma carga vertical e uma oblíqua, cada uma de 300N, foram aplicadas no centro da face oclusal da coroa de cada modelo e, em seguida, as tensões foram verificadas na região do osso periimplantar. As tensões encontradas no modelo de EF com força vertical aplicada foram 0,92 MPa na região vestibular, 1,15 MPa na lingual, 0,98 MPa na mesial e 1,00 MPa na região distal para implante de titânio. Quando utilizado implante de zircônia com carga aplicada vertical os valores de tensão foram em vestibular 11,66 MPa, em lingual 9,73 MPa, em mesial 9,76 MPa e em distal 9,59 MPa. No modelo de EF com força oblíqua de 30o os valores foram em vestibular 0,92 MPa, em lingual 1,14 MPa, em mesial 0,97 MPa e em distal 0,99 MPa com o mesmo implante de titânio. O mesmo implante com carga inclinada (30o) gerou valores de tensão de 10,23 MPa em vestibular, 8,30 MPa em lingual, 8,48 MPa em mesial e 9,51 MPa em distal. A tensão diminuiu numericamente com o implante de zircônia, com as incidências de cargas verticais e oblíquas. / This study aimed to analyze the tensions of the periimplant bone around a single implant, analyzing axial and oblique incident forces in a 3D Model using Finite Element Method. Experimental in vitro model consisted of: Brånemark System MkIIIGroovde implant (3.75 mm diameter, 13.0 mm length); multi-unit set abutment of 5mm height with titanium screw and trque of 20Nm; cobalt-chromium coping coated with feldspathic ceramic screwed with a torque of 10Nm, and olyurethane simulating the bone. Strain gauges were used to set up this experimental model and the values obtained were compared with FEM generated from the model scanning in Micro CT and developed in Simpleware software. After this, the mechanical properties of the titanium implants were replaced by the properties of Y-TZP zirconium implants in ANSYS software. A vertical and an oblique load, each one of 300N, were applied on the center of the occlusal aspect of the crown of each model and then the tensions were verified in the periimplant bone region. The tensions generated in the FE model with vertical force applied were 0.92 MPa on vestibular region, 1.15 MPa on lingual, on mesial 0.98 MPa and 1.00 MPa on distal region for titanium implant. When applied vertical load in zirconia implant, the values were 11.66 MPa on vestibular, 9.73 MPa on lingual, 9.76 MPa on mesial and 9.59 MPa on distal. In the FE model under 30o oblique load, the values were 0.92 MPa on vestibular, 1.1457 MPa on lingual, 0.97 MPa on mesial and 0.99 MPa on distal with the same titanium implant. Zirconium implant with oblique load (30o) generated tension values of 10.23 MPa on vestibular, 8.30 MPa on lingual, 8.48 MPa on mesial and 9.51 MPa on distal. The stress numerically decreased with zirconia implant with vertical and oblique loads.
106

Distribuição de tensões em coroas totais com sistema metal-free por meio do método de elementos finitos

Lima, Liliane Motta de 20 January 2016 (has links)
Submitted by Gábia Leite (gabya.leite@gmail.com) on 2016-06-24T15:24:45Z No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T14:45:15Z (GMT) No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T14:47:43Z (GMT) No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Made available in DSpace on 2016-07-05T14:47:43Z (GMT). No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) Previous issue date: 2016-01-20 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This study compared the stress distribution between three-dimensional lower first molar crowns of indirect resin Lava Ultimate (3M ESPE) (LU) and ceramic IPS e.max CAD (Ivoclar Vivadent) (Emax) against the application of functional load. Three variables were studied by the method of finite elements: the type and thickness of restorative material (1 or 2 mm) as well as the direction of the applied load (axial or oblique). On a modeling software (Rhinoceros; 5.0, Robert Mcneel & associates, USA), CAD models of total crown preparation were generated with different thicknesses of occlusal wear and their indirect restorations. Then in Femap® (10.2, Siemens PLM Software, USA) software, the construction of the finite element mesh was made. After checking the quality of this, the elastic modulus and Poisson's ratio of the tested materials were inserted in the program. After, in Nei Nastran software (10.0.3.7, NEi Software, USA), it was carried out the study of stress distribution from the simulation of models with a load of 200 N on the central fossa region and near the tip of the distobuccal cusp ridge, corresponding to a lower first molar crown. Data analysis was based on a qualitative description of the generated images and also on the values of maximum principal stress of each CAD model. According to the results, the LU crowns behaved as transmission structures of stresses and the complex tooth/restoration as a single block in which stress was distributed more evenly. In Emax crowns, however, the tensile stresses concentrated particularly along the thickness of the material. The more favorable stress distribution was obtained with the 2 mm thickness crowns in an axial occlusal load application, especially for the LU material. / O presente estudo comparou a distribuição de tensões entre coroas de primeiro molar inferior tridimensionais de resina laboratorial Lava Ultimate; 3M ESPE (LU) e de cerâmica IPS e.max CAD; Ivoclar Vivadent (Emax) frente à aplicação de carga funcional. Três variáveis foram estudadas pelo método de elementos finitos: o tipo e a espessura de material restaurador (1 e 2 mm), assim como a direção da carga aplicada (axial e oblíqua). Em um programa modelador (Rhinoceros®; versão 5.0, Robert McNeel & Associates, USA), foram gerados modelos CAD (desenhados com auxílio do computador) de preparos de coroa total com diferentes espessuras de desgaste oclusal e suas respectivas restaurações indiretas. Em seguida, no software Femap® (versão 10.2, Siemens PLM Software, USA), realizou-se a construção da malha de elementos finitos e, após a verificação da qualidade desta, o módulo de elasticidade e o coeficiente de Poisson dos materiais testados foram inseridos no programa. Posteriormente, no software Nei Nastran (versão 10.0.3.7, NEi Software, USA), realizou-se o estudo da distribuição de tensões a partir da simulação computadorizada dos modelos com um carregamento de 200 N nas regiões de fossa central e vertente triturante da cúspide médio-vestibular, correspondentes a um primeiro molar inferior. A análise dos dados baseou-se em uma descrição qualitativa das imagens geradas e nos valores obtidos das tensões principais máximas de cada modelo CAD. De acordo com os resultados, as coroas de LU se comportaram como estruturas transmissoras de tensões e o complexo dente/restauração como um bloco único no qual as tensões foram distribuídas de forma mais homogênea. Nas coroas de Emax, ao contrário, as tensões de tração se concentraram, sobretudo, ao longo da espessura do material. A distribuição de tensões mais favorável foi obtida com as coroas de 2 mm de espessura oclusal em uma aplicação axial da carga, principalmente para o material LU.
107

Avaliação das tensões ósseas geradas por prótese obturadora maxilar implanto-retida pelo sistema ERA® por meio da análise de elementos finitos / Evaluation of bone stress with implant retained obturator prosthesis with ERA® system through finite element analysis

Valéria Tognato Costa 10 May 2016 (has links)
Visando melhorar a qualidade de vida dos pacientes com perdas de estrutura maxilar faz-se necessária sua reabilitação, seja ela cirúrgica ou protética por meio de próteses obturadoras, esta última, um recurso terapêutico que minimiza os distúrbios funcionais, estéticos e psicológicos. Este estudo avaliou o comportamento biomecânico de prótese obturadora maxilar Classe II de Okay retida por implantes e sistema de retenção ERA®, observando as tensões geradas no tecido gengivo-mucoso e ósseo maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir da tomografia computadorizada de um indivíduo adulto. Quatro implantes foram posicionados na maxila, em região de incisivo lateral, canino, segundo pré-molar e primeiro molar esquerdos, onde as estruturas do sistema de retenção ERA® foram posicionadas nas extremidades de uma barra metálica e convertidas para serem representadas por superfícies. Utilizou-se o programa Rhinoceros® versão 5.0 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes, UCLAS e o CAD do sistema de retenção ERA®. O CAD do sistema ERA®, fundido em metal, foi desenvolvido a partir de imagens geradas pelo microCT SkyScan 1176 Bruke no formato BMP e TIFF. Essas imagens no formato TIFF foram exportadas para o software img2dcm, convertidas para o formato DICOM e então exportadas para o software Invesalius que reconstruiu tridimensionalmente gerando uma malha no formato STL. As estruturas finalizadas foram exportadas para software Hyperworks 13.0 e pós-processadas com a visualização de resultados pelo Hyperview, tendo sido aplicada uma força de 80N na plataforma oclusal e de 35N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de máxima tensão principal e os valores quantitativos expressos em MPa. Ocorreu um deslocamento máximo da prótese obturadora na região sem suporte ósseo, tendo como fulcro a linha de ressecção óssea. Observou-se menos forças de tração do que de compressão. As forças analisadas se mostraram bastante favoráveis à estabilidade da prótese obturadora implanto-retida por se apresentarem bem distribuídas pelo tecido gengivo-mucoso e ósseo da maxila remanescente, indicando que o sistema ERA® de retenção é adequado para reabilitação maxilar das perdas ósseas Classe II de Okay. / Searching to improve quality of life of the patients that had sustained structural maxillary loss with the necessity of rehabilitation, either through surgery or obturator prosthesis, which is a therapeutic resource to minimize functional, esthetic and psychological impairments. This study evaluated the biomechanical behavior of an Okay Class II obturator prosthesis implant retained and ERA® system, analyzing the resultant stress on the soft and bone tissue. The finite element analysis was made with a digital model constructed from a computed tomography. Four implants were positioned on the left maxillae, on the following regions: lateral incisor, canine, second premolar and first molar, with the ERA® system positioned on the extremities of a metallic bar. The software used to create the BioCAD 3D model was Rhinoceros v. 5.0, including the CAD models from the implants, UCLAS and ERA® system. The ERA® CAD model was obtained from a microCT SkyScan 1176 Bruke images, on the BMP and TIFF format. The TIFF images were exported to the img2dcm software, converted in DICOM format and finally exported to the software Invesalius, were the STL mesh was created. All mesh were imported into the software Hyperworks v. 13.0 and the post-processing was visualized on Hyperview. The force applied was of 80N over the occlusal platform and of 35N over the incisal platform. A quantitative analysis was performed, corresponding to the maximum main stress, expressed in MPa. The obturator prosthesis suffered its maximum dislocation on the region with no bone support, with the bone resection line as fulcrum. Less tension forces were observed, when comparing to compression. The forces observed were favorable to maintain the implant retained prosthesis stabilization, with good distribution over the soft and bone tissues, suggesting that the ERA® retention system is suitable to Okay Class II maxillary bone loss.
108

Análise por meio do método dos elementos finitos de um protetor bucal para atividades esportivas / Analysis through the finite element method of a mouthguard for sports activities

Felipe Andres Ortiz Poblete 01 July 2011 (has links)
O uso de protetores bucais na prática de esportes tem ampliado espaço no contexto da prevenção de traumas bucais, bem como apresentado melhoria no desempenho ao longo de sua história. O objetivo deste trabalho foi avaliar o comportamento do complexo buco dento alveolar (lábio, dentes, osso alveolar e ligamento periodontal) por meio do método dos elementos finitos. A metodologia utilizada foi a partir de um modelo em formato esterolitográfico oriundo de uma tomografia computadorizada, o qual foi convertido para um modelo 3D pelo programa Rhinoceros® versão 4.0 sem protetor bucal (controle) e com protetor bucal de 4.0mm de espessura em EVA (copolímero de etileno e acetato de vinila), os quais receberam três cargas diferentes (500, 1000 e 1500N) no programa ANSYS® v12 em regime quaseestático, de caráter elástico linear. Pudemos observar que houve um padrão de comportamento das estruturas envolvidas quanto à dissipação das tensões geradas e ao se comparar o modelo controle com o modelo provido de protetor bucal houve uma absorção das tensões geradas em até 50%, permitindo confirmar a ação do protetor bucal em literatura e tornando o seu uso imperativo durante a prática de esportes, em especial as modalidades de maior contato. / The use of mouthguards in the practice of sports has expanded space in the prevention of oral trauma, and presented performance improvement over its history. The aim of this study was to evaluate the behavior of complex buco dental alveolar (lip, teeth, periodontal ligament and alveolar bone) through the finite element method. The methodology used was based on a sterelithographic model come from a CT scan, which was converted to a 3D model by the program Rhinoceros® version 4.0 without a mouthguard (control) and mouthguard 4.0mm-thick EVA (copolymerof ethylene and vinyl acetate), which received three different loads (500, 1000 and 1500N) in ANSYS® v12 under quasi-static, linear elastic character. We noticed that there was a pattern of behavior of the structures involved and the dissipation of the tensions generated and compare the model with the control model was fitted with a mouthguard absorbs stresses generated by 50%, allowing to confirm the action of the mouthguard in literature and making its use mandatory for participation in sports, in particular the modalities for greater contact.
109

"Influência do modo de ativação do cimento resinoso e de cargas cíclicas imediatas na resistências de união entre porcelana e dentina" / Composite shrinkage stress as a function of specimen dimensions

Marcelo Ferreira Witzel 12 September 2001 (has links)
O objetivo deste estudo foi verificar a influência das dimensões do corpo-de-prova sobre a tensão de contração de um compósito em sistemas de teste com compliances conhecidos e em um sistema hipotético com compliance zero. A distribuição das tensões foi avaliada através de análise por elementos finitos. Cilindros de vidro com 2, 4 ou 6 mm de diâmetro foram fixados nas garras da máquina de ensaios (Instron 5565). As alturas dos corpos-de-prova foram definidas ajustando-se a distância entre os cilindros (0,5, 1, 2 e 4 mm). Um compósito quimicamente ativado (Bisfil 2B, Bisco) foi aplicado entre os cilindros. A força máxima após 30 min foi dividida pela área da seção transversal do corpo-de-prova para se obter a tensão nominal (MPa). A partir dos valores do módulo de elasticidade do vidro, diâmetro do cilindro e força desenvolvida, o valor da tensão nominal experimental foi corrigida para estimar a tensão que teria sido obtida caso o sistema tivesse compliance igual a zero. Estes valores foram utilizados na análise por elementos finitos. Alturas menores geraram maior tensão nominal apenas nos diâmetros 4 mm e 6 mm. Houve uma correlação linear direta entre tensão e fator-C. Porém, o efeito de borda ficou evidente nas curvas dos dados agrupados por diâmetro. Não houve relação entre tensão nominal e volume de compósito para todo o conjunto de dados. A correção da tensão resultou em valores mais altos e ampliou as diferenças de tensão entre as alturas. A simulação por elementos finitos evidenciou pronunciado efeito de borda em situações de alto confinamento e os valores da tensão máxima de Von Mises foram mais altos do que a tensão nominal 9 corrigida em qualquer condição experimental. Foi possível concluir que as dimensões do espécime influenciaram os valores de tensão nominal. É possível inferir que a eliminação do compliance tornaria esta influência mais evidente. Existe um pronunciado efeito de borda neste tipo de ensaio, principalmente em condições de alto confinamento. / The objective of the present study was verify the influence of specimen dimensions on polymerization shrinkage stress of a dental composite in testing systems of known compliance and in a hypothetical system with zero compliance. Stress distribution was evaluated using finite element analysis. Glass rods with 2, 4, or 6 mm diameters were attached to a universal testing machine (Instron 5565). Specimen height was defined by adjusting the distance between the rods (0.5, 1, 2 or 4 mm). A self-cure composite (Bisfil 2B, Bisco) was applied between them. Maximum contraction force after 30 min was divided by the cross-sectional area of the specimen in order to obtain nominal stress (MPa). The corrected nominal stress was calculated using the elastic modulus and elongation of the components of the system, together with the force registered during testing. Corrected values were used in the finite element analysis. Shorter specimens generated higher nominal stress only for the 4 mm and 6 mm specimens. There was a direct linear correlation between stress and C-factor. However, the effect of boundary restraints became evident when data were grouped by diameter. No correlation was found between nominal stress and specimen volume. Data correction for compliance amplified the differences in stress produced by different heights. Finite elements analysis revealed an accentuated boundary effect in high confinement groups. Maximum Von Mises stress was higher than corrected nominal stress in all groups. It was concluded that specimen dimensions influenced test results. Eliminating the influence of system compliance made the effect of specimen 11 dimensions on stress more evident. Boundary restraints have a strong influence in test results, mostly in highly confined conditions.
110

Análise biomecânica de dentes restaurados com retentor intra-radicular fundido, com e sem férula / Biomechanics analysis of restored teeth with cast intra-radicular retainer, with and without ferrule

Isis Andrea Venturini Pola Poiate 11 December 2007 (has links)
O objetivo foi avaliar a influência de variações no formato da férula dada por núcleo estojado sobre as tensões desenvolvidas na raiz em um modelo tridimensional de um segundo pré-molar superior submetido a quatro condições de carregamentos: cunha, alavanca vestibular, alavanca proximal e torção. Seis modelos foram confeccionados a partir das dimensões médias obtidas na literatura. Um deles representou o dente hígido, e outros cinco dentes restaurados com coroa e retentor intra-radicular fundido: um simulou núcleo simples, sem férula (E2A0), e em quatro modelos variou-se o tamanho do espelho (E) em 1/3 da espessura da parede radicular (E1) ou 2/3 (E2) e a altura (A) da férula foi equivalente a E1 (A1) ou a E2 (A2); ou seja: os modelos E1A1 e E2A2 tiveram 45º de inclinação do bisel da férula. Todas as estruturas foram consideradas homogêneas, isotrópicas e lineares elásticas. Os resultados permitem afirmar que a férula não parece necessária para melhorar a distribuição de tensões e que, exceto para o caso de carregamento longitudinal (que demonstrou ser o menos danoso), o cimento ficou submetido a tensões que justificam sua fratura e a dentina apresentou tensões de tração compatíveis com fraturas longitudinais (com início na crista óssea), especialmente para a alavanca vestibular. / The aim was to evaluate the influence of variations in the radicular ferrule format given by the casing core on stress developed in the root in a three-dimensional model of one upper second premolar submitted to four load conditions: wedge, vestibular lever, proximal lever and torsion. Six models were built according the average dimensions obtained from the literature. One of them represented the sound tooth, and other five restored teeth with cast radicular retainer and crown: one simulated simple core, without ferrule (E2A0), and in four models the mirror (E) size was varied in 1/3 of the radicular wall thickness (E1) or 2/3 (E2) and the ferrule height (A) was equivalent to E1 (A1) or E2 (A2); or be: E1A1 and E2A2 had 45º inclination of the ferrule bisel. All the structures were considered homogeneous, isotropic and linear elastic behavior. The results allow to affirm that the ferrule doesn\'t seem necessary to improve the stress distribution and that, except for the longitudinal load case (that demonstrated to be the least harmful), the cement was submitted to stress that justify his fracture and the dentine presented compatible tensile stress with longitudinal fractures (with beginning in the bone crest), especially for the vestibular lever.

Page generated in 0.1136 seconds