• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • Tagged with
  • 136
  • 136
  • 129
  • 129
  • 81
  • 75
  • 63
  • 63
  • 57
  • 57
  • 46
  • 43
  • 40
  • 40
  • 39
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Fexofenadina : validação de métodos analíticos e estudo de fotoestabilidade

Breier, Ana Rita January 2007 (has links)
Este trabalho objetivou o desenvolvimento e validação de métodos analíticos para determinação de fexofenadina em cápsulas e comprimidos revestidos e o estudo de fotoestabilidade do fármaco. A determinação da faixa de fusão e a espectrofotometria no infravermelho permitiram identificar fexofenadina substância química de referência. Os métodos por cromatografia em camada delgada, espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para análise qualitativa do fármaco nas formas farmacêuticas. A determinação quantitativa foi realizada através da validação dos métodos por UV e CLAE para cápsulas e comprimidos e EC para cápsulas, avaliando-se os parâmetros descritos pelas guias de validação. Os métodos propostos não apresentaram diferença estatística para um nível de significância de 1%. O teste de dissolução foi desenvolvido e validado utilizando HCl 0,01 M como meio de dissolução, cestas a 100 rpm e pás a 75 rpm para cápsulas e comprimidos revestidos, respectivamente. Perfis de dissolução de cápsulas dos medicamentos referência e similar e comprimidos revestidos dos medicamentos referência, similar e genérico foram realizados e comparados através dos fatores de diferença e semelhança e da eficiência de dissolução e não apresentaram-se semelhantes. Estudo preliminar de estabilidade de fexofenadina frente à degradação ácida, alcalina, oxidativa, térmica e fotolítica mostrou a oxidação e a luz como fatores importantes de degradação. A cinética de fotodegradação de fexofenadina em soluções metanólica e aquosa demonstrou cinética de segunda ordem de reação. A estabilidade acelerada da fexofenadina foi realizada utilizando-se soluções metanólicas pH=6 e pH=11, as quais foram expostas às lâmpadas metal haleto e UVC 254 nm, havendo formação dos produtos majoritários, denominados PD-21 e PD-37, os quais foram isolados por cromatografia em coluna e CCD preparativa. A fotólise do pó de comprimidos e de comprimidos demonstrou haver formação dos mesmos produtos de degradação obtidos em solução. Os produtos foram identificados por ressonância magnética nuclear e espectrometria de massas como derivados benzofenona (PD-21) e isopropílico (PD-37) da fexofenadina. / The aim of this study was the development and validation of analytical methods to the determination of fexofenadine in capsules and coated tablets and the photostability study of the drug. The melting range determination and infrared spectrophotometry allowed fexofenadine standard reference identification. Methods of thin-layer chromatography (TLC), ultraviolet spectrophotometry (UV), high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) were employed to the qualitative analysis of the drug in pharmaceutical formulations. The quantitative determination was performed through the validation of UV and HPLC for capsules and coated tablets, and CE for capsules, evaluating the guidances validation parameters. The proposed methods were not statistically different to a 1% significance level. The dissolution test was developed and validated using HCl 0,01 M as dissolution medium, basket at 100 rpm and paddle at 75 rpm to capsules and coated tablets, respectively. Dissolution profiles of reference and similar capsule products and reference, similar and generic coated tablets products were performed and compared using difference factor, similarity factor and the dissolution efficiency, showing not similarity. Preliminary stability study of fexofenadine through acid, alkaline, oxidative, thermal, and photolytic degradation shows sensibility to oxidation and light. The kinetic of photodegradation of fexofenadine in methanol and water solutions show second order kinetic of reaction. The accelerated stability was evaluated using fexofenadine methanolic solutions pH=6 and pH=11, which were exposed to a metal halide lamp and to a fluorescent lamp UVC 254 nm, giving two majority degradation products, assigned PD-21 and PD-37. The separation was carried out by HPLC and TLC. The products were isolated by column chromatography and preparative TLC techniques. The analysis of the powder of tablets and tablets, which were exposed to light, showed the same degradation products presented for solutions. The majority degradation products of fexofenadine were identified by nuclear magnetic resonance and mass spectrometry as a benzophenone derivative (PD-21) and isopropyl derivative (PD-37).
52

Fexofenadina : validação de métodos analíticos e estudo de fotoestabilidade

Breier, Ana Rita January 2007 (has links)
Este trabalho objetivou o desenvolvimento e validação de métodos analíticos para determinação de fexofenadina em cápsulas e comprimidos revestidos e o estudo de fotoestabilidade do fármaco. A determinação da faixa de fusão e a espectrofotometria no infravermelho permitiram identificar fexofenadina substância química de referência. Os métodos por cromatografia em camada delgada, espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para análise qualitativa do fármaco nas formas farmacêuticas. A determinação quantitativa foi realizada através da validação dos métodos por UV e CLAE para cápsulas e comprimidos e EC para cápsulas, avaliando-se os parâmetros descritos pelas guias de validação. Os métodos propostos não apresentaram diferença estatística para um nível de significância de 1%. O teste de dissolução foi desenvolvido e validado utilizando HCl 0,01 M como meio de dissolução, cestas a 100 rpm e pás a 75 rpm para cápsulas e comprimidos revestidos, respectivamente. Perfis de dissolução de cápsulas dos medicamentos referência e similar e comprimidos revestidos dos medicamentos referência, similar e genérico foram realizados e comparados através dos fatores de diferença e semelhança e da eficiência de dissolução e não apresentaram-se semelhantes. Estudo preliminar de estabilidade de fexofenadina frente à degradação ácida, alcalina, oxidativa, térmica e fotolítica mostrou a oxidação e a luz como fatores importantes de degradação. A cinética de fotodegradação de fexofenadina em soluções metanólica e aquosa demonstrou cinética de segunda ordem de reação. A estabilidade acelerada da fexofenadina foi realizada utilizando-se soluções metanólicas pH=6 e pH=11, as quais foram expostas às lâmpadas metal haleto e UVC 254 nm, havendo formação dos produtos majoritários, denominados PD-21 e PD-37, os quais foram isolados por cromatografia em coluna e CCD preparativa. A fotólise do pó de comprimidos e de comprimidos demonstrou haver formação dos mesmos produtos de degradação obtidos em solução. Os produtos foram identificados por ressonância magnética nuclear e espectrometria de massas como derivados benzofenona (PD-21) e isopropílico (PD-37) da fexofenadina. / The aim of this study was the development and validation of analytical methods to the determination of fexofenadine in capsules and coated tablets and the photostability study of the drug. The melting range determination and infrared spectrophotometry allowed fexofenadine standard reference identification. Methods of thin-layer chromatography (TLC), ultraviolet spectrophotometry (UV), high performance liquid chromatography (HPLC), and capillary electrophoresis (CE) were employed to the qualitative analysis of the drug in pharmaceutical formulations. The quantitative determination was performed through the validation of UV and HPLC for capsules and coated tablets, and CE for capsules, evaluating the guidances validation parameters. The proposed methods were not statistically different to a 1% significance level. The dissolution test was developed and validated using HCl 0,01 M as dissolution medium, basket at 100 rpm and paddle at 75 rpm to capsules and coated tablets, respectively. Dissolution profiles of reference and similar capsule products and reference, similar and generic coated tablets products were performed and compared using difference factor, similarity factor and the dissolution efficiency, showing not similarity. Preliminary stability study of fexofenadine through acid, alkaline, oxidative, thermal, and photolytic degradation shows sensibility to oxidation and light. The kinetic of photodegradation of fexofenadine in methanol and water solutions show second order kinetic of reaction. The accelerated stability was evaluated using fexofenadine methanolic solutions pH=6 and pH=11, which were exposed to a metal halide lamp and to a fluorescent lamp UVC 254 nm, giving two majority degradation products, assigned PD-21 and PD-37. The separation was carried out by HPLC and TLC. The products were isolated by column chromatography and preparative TLC techniques. The analysis of the powder of tablets and tablets, which were exposed to light, showed the same degradation products presented for solutions. The majority degradation products of fexofenadine were identified by nuclear magnetic resonance and mass spectrometry as a benzophenone derivative (PD-21) and isopropyl derivative (PD-37).
53

Nitazoxanida : desenvolvimento e validação de métodos analíticos e estudo da estabilidade / Nitazoxanide: development and validation of analytical methods and stability study

Malesuik, Marcelo Donadel January 2010 (has links)
A nitazoxanida é um novo antiparasitário de amplo espectro e pertence à classe dos nitrotiazóis. No Brasil, encontra-se disponível na forma de comprimidos revestidos e pó para suspensão oral, sob nome cormercial de Annita . A análise de fármacos é necessária em todas as fases do desenvolvimento farmacêutico e na manutenção da segurança e eficácia terapêutica dos produtos comercializados. Assim, o presente trabalho objetivou o desenvolvimento e validação de métodos para análise qualitativa e quantitativa da nitazoxanida nas formas farmacêuticas comerciais e a avaliação da estabilidade do fármaco em condições de degradação forçada, contemplando a determinação da cinética de fotodegradação e o isolamento, identificação e estudo da citotoxicidade do produto de degradação majoritário. As análises por espectrometria de massas (MS/MS), infravermelho (IV), ressonância magnética nuclear (RMN 1H e 13C) e calorimetria exploratória diferencial permitiram identificar a nitazoxanida utilizada como substância química de referência. Os métodos por cromatografia em camada delgada, espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para identificação do fármaco nas formas farmacêuticas. Os métodos quantitativos validados foram: UV, CLAE e EC. Todos cumpriram com os parâmetros descritos pelas guias de validação e não apresentaram diferença estatística significativa na determinação do fármaco. O estudo preliminar de estabilidade frente à degradação oxidativa, ácida, básica, térmica e fotolítica demonstrou que o fármaco é instável em todas as condições testadas, sendo que os meios oxidativo, alcalino e fotolítico foram os fatores de maior importância. A cinética de fotodegradação da nitazoxanida apresentou cinética de ordem zero para ambas as formas farmacêuticas. Em todas as condições de degradação testadas ocorreu a formação de um produto de degradação majoritário, chamado de PD1, o qual precipitou nas condições analíticas e foi isolado por filtração. O mesmo foi identificado por RMN 1H e 13C, EM/EM e IV como o derivado desacetilado da nitazoxanida, a tizoxanida. A avaliação preliminar da citotoxicidade indicou que o produto isolado apresenta maior toxicidade celular in vitro após 48 horas de incubação frente à células mononucleares, quando comparado à nitazoxanida. Os resultados obtidos neste trabalho demonstram a importância do aprofundamento dos estudos nesta área para garantir a segurança e eficácia terapêutica dos produtos farmacêuticos comercializados. / Nitazoxanide is a new broad-spectrum antiparasitic drug and it belongs to the class of nitrothiazol. In Brazil, it is available as tablets and powder for oral suspension, under the cormercial name of Annita . Drug analysis is needed in all phases of pharmaceutical development and maintenance of marketed products safety and efficacy. Thus, the present study aimed the methods development and validation for qualitative and quantitative analysis of nitazoxanide in commercial pharmaceutical forms and evaluation of drug stability in forced degradation conditions, comprising the photodegradation kinetics determination and the isolation, identification and the cytotoxicity study of the major degradation product. The analysis by mass spectrometry (MS/MS), infrared (IR), nuclear magnetic resonance (1H and 13C NMR) and differential scanning calorimetry allows to identify the nitazoxanide chemical reference structure. The methods by thin layer chromatography, spectrophotometry (UV), high performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to identify the drug in pharmaceutical formulations. Quantitative methods have been validated: UV, HPLC and CE. All methods met the criteria described by the validation guidelines and showed no significant statistically difference in the drug determination. The preliminary stability study of nitazoxanide under oxidative, acidic, basic, thermal and photolytic conditions showed that the drug is unstable in all tested conditions, and oxidative, alkaline and photolytic conditions are the factors of major importance. The photodegradation kinetics of nitazoxanide showed zero-order kinetics for both dosage forms. In all tested degradation conditions it was formed a majority degradation product, named PD1, which precipitated in the analytical conditions and it was isolated by filtration. The same product was identified by 1H and 13C NMR, MS/MS and IR as deacetylated derivative of nitazoxanide, the Tizoxanide. The preliminary citotoxicity evaluation indicated that the isolated product has a higher cellular toxicity in vitro after 48 hours of incubation, when compared to nitazoxanide. The results demonstrate the importance of this type of study to ensure the safety and efficacy of marketed pharmaceutical products.
54

Telitromicina : métodos de análise, ensaio de dissolução e estudo da estabilidade / Telithromycin : analytical methods, dissolution test and stability study

Vaucher, Lauren Rosa Crossetti January 2007 (has links)
A telitromicina é o primeiro representante de uma nova família de antibióticos os cetolídeos. Os cetolídeos são derivados semi-sintéticos dos macrolídeos. No Brasil encontra-se disponível na forma de comprimidos revestidos com o nome comercial de Ketek®. Este trabalho objetivou o desenvolvimento e validação de métodos analíticos para determinação da telitromicina em comprimidos revestidos, desenvolvimento e validação do ensaio de dissolução e estudo da estabilidade do fármaco. A determinação da faixa de fusão e a espectrofotometria no infravermelho permitiram identificar a telitromicina substância química de referência. Os métodos por cromatografia em camada delgada (CCD), espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (CLAE), foram utilizados para análise qualitativa do fármaco na forma farmacêutica. A determinação quantitativa foi realizada através da validação dos métodos por UV, CLAE e ensaio microbiológico. Os métodos propostos não apresentaram diferença estatística para um nível de significância de 1%. O teste de dissolução foi desenvolvido e validado na condição mais discriminatória obtida. Após seleção, a condição escolhida foi tampão fosfato de sódio pH 7,5, como meio de dissolução e pás a 50 rpm. Estudo preliminar da estabilidade de telitromicina frente à degradação ácida, alcalina, oxidativa , térmica e fotolítica mostrou a oxidação e a luz como fatores importantes de degradação. A cinética de fotodegradação e oxidativa demonstrou cinética de primeira ordem de reação. A estabilidade acelerada da telitromicina foi realizada pela oxidação em peróxido de hidrogênio havendo formação de um produto majoritário denominado PD10 o qual foi isolado por CLAE em coluna semi-preparativa. O produto foi identificado por ressonância magnética nuclear como derivado N-óxido da telitromicina. / Telithromycin is the first member of a new antibiotic class named ketolides. The ketolides are derived from macrolides class. In Brazil it is available in coated tablets with the commercial name of ketek®. The aim of this study was the development and validation of analytical methods to the determination of telithromycin in coated tablets, the development and validation of dissolution test and the stability study of the drug. The melting range determination and infrared spectrophotometric allowed telithromycin standard reference identification. Methods of thin-layer chromatography (TLC), ultraviolet spectrophotometry (UV), high performance liquid chromatography (HPLC) were employed to the qualitative analysis of the drug in pharmaceutical formulations. The quantitative determination was performed through the validation of UV, HPLC and microbiological assay, evaluating the guidances validation parameters. The proposed methods were not statically different to a 1% significance level. The dissolution test was developed and validated using the most discriminatory condition obtained, sodium phosphate buffer pH 7.5 as dissolution medium and paddle at 50 rpm. Preliminary stability study of telithromycin through acid, alkaline, oxidative, thermal and photolytic degradation shows sensibility to oxidation and light. The kinetics of photo degradation and oxidative degradation of telithromycin showed first order kinetics of reactions. The accelerated stability of telithromycin was evaluated through the oxidation by hydrogen peroxide giving one majority degradation product, assigned PD10. The separation was carried out by HPLC. The product was isolated by semi preparative column chromatographic. The majority degradation product of telithromycin was identified by nuclear magnetic resonance as an N-oxide derivative.
55

Avaliação da fotoestabilidade do cetoconazol e determinação da atividade antifúngica e da segurança biológica in vivo e in vitro do xampu de cetoconazol / Photostability evaluation of ketoconazole and determination of the antifungal activity and biological reactivity in vivo and in vitro of ketoconazole shampoo

Staub, Inara January 2005 (has links)
Cetoconazol é um agente antifúngico que possui ação tópica e sistêmica, podendo ser incorporado em diferentes formas farmacêuticas. Como exemplo, pode-se citar o xampu de cetoconazol, que é efetivo no tratamento da dermatite seborréica e pitiríase versicolor. É reconhecido que o cetoconazol, nas formas farmacêuticas xampu e solução, rapidamente altera a coloração se tornando avermelhado. A exposição de fármacos à radiação pode influenciar a estabilidade da formulação, levando a modificações nas propriedades físico-químicas do produto. O objetivo deste trabalho foi avaliar a fotoestabilidade do cetoconazol em xampu e solução. As formulações foram expostas à radiação UV-A (352 nm), UV-C (254 nm) e luz diurna. Métodos foram desenvolvidos e validados para a determinação quantitativa do cetoconazol: cromatografia líquida de alta eficiência e ensaio microbiológico utilizando o método de cilindros em placa. Estudos comparativos entre xampu de cetoconazol e xampu de cetoconazol contendo produtos de degradação foram feitos para avaliar a atividade antifúngica e a segurança biológica in vivo (teste de Draize) e in vitro (teste de citotoxicidade). Os resultados demonstraram diminuição na atividade antifúngica, mas não demonstraram alteração na segurança biológica. Os métodos utilizados para análise do cetoconazol (ensaio microbiológico e CLAE) demonstraram ser lineares, precisos e exatos, sendo úteis no controle de qualidade do fármaco. Os resultados indicam alteração do cetoconazol em presença da luz. Dois produtos de degradação foram isolados e identificados: 1-acetil-4-{4-[2-(2-clorofenil)-2-(1H-imidazolil-1- metil)-1,3-dioxolanil-4-metoxi]fenil}piperazina e 1-acetil-4-{4-[2-(4-clorofenil)-2- (1H-imidazolil-1-metil)-1,3-dioxolanil-4-metoxi]fenil}piperazina. Conseqüentemente, adequada proteção da luz deve ser adotada durante armazenamento das duas formas farmacêuticas contendo o fármaco. / Ketoconazole is an antifungal agent with topic and systemic action and can be incorporated into several dosage forms. As an example, it could be mentioned ketoconazole shampoo, which is effective against seborrhoeic dermatitis and pityriasis versicolor. It is remarkable that ketoconazole is rapidly altered in shampoo and solution dosage forms, since its colour turns into red. Exposure of a drug to radiation can influence the stability of the formulation, leading to changes in the physicochemical properties of the product. The aim of this work was to assess the photostability of ketoconazole in shampoo and solution. The formulations were exposed to UV-A (352 nm) and UV-C (254 nm) radiations and daylight. Methods were developed and validated for the quantitative determination of ketoconazole: high performance liquid chromatography and microbiological assay using the cylinder-plate method. Comparative studies between ketoconazole shampoo and ketoconazole shampoo containing degradation products were conducted to evaluated the antifungal activity and biological reactivity in vivo (Draize test) and in vitro (cytotoxity test). The results showed a decrease in antifungal activity but not an alteration on the biological reactivity. The methods used for ketoconazole analysis (microbiological assay and HPLC) were linear, precise and accurate, providing valuable methods for the quality control of this drug. The results indicate alteration in ketoconazole in presence of light. Two photodegradation products were isolated and identified: 1-acetyl-4-{4-[2-(2-chlorophenyl)-2-(1H-imidazol- 1-ylmethyl)-1,3-dioxolan-4-ylmethoxy]phenyl}piperazine and 1-acetyl-4-{4-[2- (4-chlorophenyl)-2-(1H-imidazol-1-ylmethyl)-1,3-dioxolan-4-ylmethoxy]phenyl} piperazine. Consequently, adequate light protection should be adopted for storage of these two dosage forms containing the drug.
56

Desenvolvimento e validação de métodos analíticos e estudo de estabilidade de etexilato de dabigatrana em cápsulas / Development and validation of analytical methods and stability study of dabigatran etexilate in capsules

Bernardi, Raquel Martini January 2013 (has links)
Etexilato de dabigatrana (DAB) é um pró-fármaco da dabigatrana disponível para administração oral. DAB é um inibidor direto da trombina, desenvolvido para prevenção de acidente vascular cerebral e embolia sistêmica em pacientes com fibrilação atrial e para a prevenção de eventos tromboembólicos em pacientes que se submeteram à cirurgia de artroplastia total de joelho e de quadril. Atualmente, não há métodos publicados para a análise qualitativa e quantitativa e estudos de estabilidade de DAB em cápsulas. Portanto, inicialmente, a caracterização da substância química de referência foi realizada por espectrometria de massas (EM), espectroscopia de absorção no infravermelho, espectroscopia de ressonância magnética nuclear de 1H e calorimetria exploratória diferencial. Os métodos por cromatografia em camada delgada, CLAE utilizando detectores UV, CAD e EM foram usados para identificar o fármaco nas cápsulas. Na sequência, foram desenvolvidos métodos empregando a cromatografia líquida de alta eficiência (CLAE) com detector ultravioleta (CLAE-UV) e detector aerossol carregado (CLAECAD) para a quantificação de DAB em cápsulas. Os mesmos foram validados, avaliando-se parâmetros como especificidade, linearidade, precisão, exatidão, robustez e limites de detecção e quantificação. Os métodos foram comparados estatisticamente por ANOVA e nenhuma diferença estatisticamente significante foi encontrada entre os mesmos. O estudo de estabilidade de DAB frente à degradação térmica foi investigado. Através dos métodos por CLAE-UV e CLAE-EM pode-se propor a identidade dos produtos de degradação formados, sem processo de isolamento ou purificação. Adicionalmente, a cinética de degradação do DAB e a citotoxicidade das amostras degradadas também foram estudadas. O estudo de cinética de degradação térmica apresentou cinética de primeira ordem (R2 = 0,9900). Além disso, nenhuma evidência de citotoxicidade in vitro em estudo utilizando células mononucleares humanas foi observada. Desse modo estabeleceram-se procedimentos que podem ser aplicados para aprimorar o controle de qualidade, contribuindo para assegurar a eficácia terapêutica de produtos à base de DAB. / Dabigatran etexilate (DAB) is an orally available prodrug of dabigatran. DAB is a direct thrombin inhibitor, developed for stroke and systemic embolism prevention in patients with atrial fibrillation and prevention of venous thromboembolic events in patients who have undergone elective total hip replacement or total knee replacement surgery. Currently, there are no methods published for the qualitative and quantitative analysis and stability study of DAB in capsules. Thus, initially, the characterization of the chemical reference substance was performed by mass spectrometry (MS), infrared spectroscopy, 1H nuclear magnetic resonance spectroscopy and differencial scanning calorimetry. The methods by thin-layer chromatography, LC using UV and CAD detector and LC-MS were used to identify the drug in capsule. High performance liquid chromatographic (LC) methods were developed for the assessment of dabigatran etexilate (DAB) in capsules with ultraviolet detector (LC-UV) and charged aerosol detector (LC-CAD). They were validated by evaluating parameters such as specificity, linearity, precision, accuracy, robustness and limits of detection and quantitation. The methods were compared statistically by ANOVA and no statistic difference was found between them. The stability study of DAB under thermal condition was investigated. The degradation products formed were analyzed by LC-UV and LC-MS methods and it’s identify could be suggested, without isolation or purification process. Additionally, the thermal degradation kinetic of DAB and the cytotoxicity of the degraded samples were also studied. The kinetics results could be best described as first-order process (R2 = 0.9900). No evidence of cytotoxicity in human mononuclear cell was observed for drugs degraded samples. So, procedures which can be applied to improve the quality control and contribute to ensure the therapeutic efficacy of products containing DAB.
57

Desenvolvimento e validação de metodologia analítica para bromidrato de darifenacina comprimido / Development and validation of the analytical method for the darifenacin hydrobromide tablet

Meneghini, Leonardo Zanchetti January 2011 (has links)
O objetivo deste trabalho foi o desenvolvimento e validação de métodos analíticos para determinação do bromidrato de darifenacina (DF) em comprimidos de liberação modificada. Na fase de identificação, a matéria-prima do fármaco (substância química de referência) foi analisada e caracterizada utilizando-se de medidas físicas (ponto de fusão, polarimetria, solubilidade), espectroscopia (infravermelho, ultravioleta-visível, massas) e técnicas cromatográficas (cromatografia a líquido de alta eficiência, cromatografia em camada delgada). Nos estágios posteriores, os experimentos para quantificação do comprimido foram realizados utilizando-se de desenhos experimentais (fatoriais completes, desenhos de composto central, fatoriais fracionados). O método de CLAE foi validado e um produto de degradação foi obtido na condição de estresse oxidativo (H2O2 13%, 72h). Para o método espectrofotométrico, a interferência de excipientes foi verificada e a técnica de derivada (método zero-crossing) foi utilizada para quantificação. Ambos os métodos foram comparados e não demonstram diferença significativa quando aplicados ao doseamento do comprimido. / The aim of this study was the development and validation of the analytical methods to the determination of darifenacin hydrobromide (DF) in extended-release tablet. In the identification stage, the bulk drug was analyzed and characterized using physical measures (melting point, polarimetry, solubility), spectroscopy (infrared and ultraviolet-visible) and chromatographic techniques (high performance liquid chromatographic, HPLC, and thin-layer chromatography, TLC). In the subsequent stages, the experiments to quantification for the DF tablet were performed using experimental designs (full factorial designs, central composite designs and fractional factorial designs). The HPLC method was validated and a degradation product was obtained in oxidation stress condition (H2O2 13%, 72h). For the spectrophotometric method, excipient interference was observed and derivative technique (zero-crossing method) was employed to quantification. Both the methods were compared showing no signficative difference to tablet assay.
58

Desenvolvimento e validação de métodos analíticos e estudo de estabilidade de etexilato de dabigatrana em cápsulas / Development and validation of analytical methods and stability study of dabigatran etexilate in capsules

Bernardi, Raquel Martini January 2013 (has links)
Etexilato de dabigatrana (DAB) é um pró-fármaco da dabigatrana disponível para administração oral. DAB é um inibidor direto da trombina, desenvolvido para prevenção de acidente vascular cerebral e embolia sistêmica em pacientes com fibrilação atrial e para a prevenção de eventos tromboembólicos em pacientes que se submeteram à cirurgia de artroplastia total de joelho e de quadril. Atualmente, não há métodos publicados para a análise qualitativa e quantitativa e estudos de estabilidade de DAB em cápsulas. Portanto, inicialmente, a caracterização da substância química de referência foi realizada por espectrometria de massas (EM), espectroscopia de absorção no infravermelho, espectroscopia de ressonância magnética nuclear de 1H e calorimetria exploratória diferencial. Os métodos por cromatografia em camada delgada, CLAE utilizando detectores UV, CAD e EM foram usados para identificar o fármaco nas cápsulas. Na sequência, foram desenvolvidos métodos empregando a cromatografia líquida de alta eficiência (CLAE) com detector ultravioleta (CLAE-UV) e detector aerossol carregado (CLAECAD) para a quantificação de DAB em cápsulas. Os mesmos foram validados, avaliando-se parâmetros como especificidade, linearidade, precisão, exatidão, robustez e limites de detecção e quantificação. Os métodos foram comparados estatisticamente por ANOVA e nenhuma diferença estatisticamente significante foi encontrada entre os mesmos. O estudo de estabilidade de DAB frente à degradação térmica foi investigado. Através dos métodos por CLAE-UV e CLAE-EM pode-se propor a identidade dos produtos de degradação formados, sem processo de isolamento ou purificação. Adicionalmente, a cinética de degradação do DAB e a citotoxicidade das amostras degradadas também foram estudadas. O estudo de cinética de degradação térmica apresentou cinética de primeira ordem (R2 = 0,9900). Além disso, nenhuma evidência de citotoxicidade in vitro em estudo utilizando células mononucleares humanas foi observada. Desse modo estabeleceram-se procedimentos que podem ser aplicados para aprimorar o controle de qualidade, contribuindo para assegurar a eficácia terapêutica de produtos à base de DAB. / Dabigatran etexilate (DAB) is an orally available prodrug of dabigatran. DAB is a direct thrombin inhibitor, developed for stroke and systemic embolism prevention in patients with atrial fibrillation and prevention of venous thromboembolic events in patients who have undergone elective total hip replacement or total knee replacement surgery. Currently, there are no methods published for the qualitative and quantitative analysis and stability study of DAB in capsules. Thus, initially, the characterization of the chemical reference substance was performed by mass spectrometry (MS), infrared spectroscopy, 1H nuclear magnetic resonance spectroscopy and differencial scanning calorimetry. The methods by thin-layer chromatography, LC using UV and CAD detector and LC-MS were used to identify the drug in capsule. High performance liquid chromatographic (LC) methods were developed for the assessment of dabigatran etexilate (DAB) in capsules with ultraviolet detector (LC-UV) and charged aerosol detector (LC-CAD). They were validated by evaluating parameters such as specificity, linearity, precision, accuracy, robustness and limits of detection and quantitation. The methods were compared statistically by ANOVA and no statistic difference was found between them. The stability study of DAB under thermal condition was investigated. The degradation products formed were analyzed by LC-UV and LC-MS methods and it’s identify could be suggested, without isolation or purification process. Additionally, the thermal degradation kinetic of DAB and the cytotoxicity of the degraded samples were also studied. The kinetics results could be best described as first-order process (R2 = 0.9900). No evidence of cytotoxicity in human mononuclear cell was observed for drugs degraded samples. So, procedures which can be applied to improve the quality control and contribute to ensure the therapeutic efficacy of products containing DAB.
59

Desenvolvimento e validação de metodologia analítica para bromidrato de darifenacina comprimido / Development and validation of the analytical method for the darifenacin hydrobromide tablet

Meneghini, Leonardo Zanchetti January 2011 (has links)
O objetivo deste trabalho foi o desenvolvimento e validação de métodos analíticos para determinação do bromidrato de darifenacina (DF) em comprimidos de liberação modificada. Na fase de identificação, a matéria-prima do fármaco (substância química de referência) foi analisada e caracterizada utilizando-se de medidas físicas (ponto de fusão, polarimetria, solubilidade), espectroscopia (infravermelho, ultravioleta-visível, massas) e técnicas cromatográficas (cromatografia a líquido de alta eficiência, cromatografia em camada delgada). Nos estágios posteriores, os experimentos para quantificação do comprimido foram realizados utilizando-se de desenhos experimentais (fatoriais completes, desenhos de composto central, fatoriais fracionados). O método de CLAE foi validado e um produto de degradação foi obtido na condição de estresse oxidativo (H2O2 13%, 72h). Para o método espectrofotométrico, a interferência de excipientes foi verificada e a técnica de derivada (método zero-crossing) foi utilizada para quantificação. Ambos os métodos foram comparados e não demonstram diferença significativa quando aplicados ao doseamento do comprimido. / The aim of this study was the development and validation of the analytical methods to the determination of darifenacin hydrobromide (DF) in extended-release tablet. In the identification stage, the bulk drug was analyzed and characterized using physical measures (melting point, polarimetry, solubility), spectroscopy (infrared and ultraviolet-visible) and chromatographic techniques (high performance liquid chromatographic, HPLC, and thin-layer chromatography, TLC). In the subsequent stages, the experiments to quantification for the DF tablet were performed using experimental designs (full factorial designs, central composite designs and fractional factorial designs). The HPLC method was validated and a degradation product was obtained in oxidation stress condition (H2O2 13%, 72h). For the spectrophotometric method, excipient interference was observed and derivative technique (zero-crossing method) was employed to quantification. Both the methods were compared showing no signficative difference to tablet assay.
60

Eletrodos quimicamente modificados com Poli (benzil viologênio): comportamento eletroquímico de fármacos nitroderivados. / Chemically modified electrodes with Poly (benzyl viologen): electrochemical behavior of nitro derivative drugs.

Deliberto, Laíla Aparecida 15 March 2013 (has links)
Na área da saúde, destacam-se alguns fármacos amplamente administrados, os quais possuem grupamentos nitro em suas moléculas, como o Clonazepam (CNZ), Nitrazepam (NTZ) e Nimesulida (Nimes). O CNZ e o NTZ são utilizados ilicitamente em coquetéis entorpecentes, fragilizando vítimas. A Nimes é anti-inflamatório amplamente administrado e frequentemente usado sem prescrição médica. As metodologias de detecção e quantificação destes fármacos são, na sua maioria, dispendiosas, desenvolvidas por HPLC, GC, etc. Poucos trabalhos utilizam determinação eletroanalítica e dentre eles, menos ainda utilizam eletrodos quimicamente modificados (EQMs). Os EQMs melhoram a seletividade e sensibilidade das análises. Dentre as formas de modificação, a metodologia de filmes poliméricos é muito versátil e possibilita o desenvolvimento de eletrodos específicos. Uma classe importante de polímeros é a dos derivados de viologênio, como o Poli (benzil viologênio) (PBV). Este polímero é empregado com diferentes finalidades. Possui três estados de oxidação, um deles; o PBV+ atua como mediador redox. E, a partir de experimentos prévios em nosso laboratório demonstrou ainda a possibilidade de atuar na redução de nitrocompostos. Neste sentido, este trabalho determinou as melhores condições experimentais para obtenção de um EQM com o PBV para seu emprego em análise e quantificação de fármacos nitroderivados (CNZ, NTZ e Nimes), bem como em amostras comerciais, utilizando a técnica de voltametria cíclica. Este trabalho contribuiu para o desenvolvimento de uma metodologia eficaz de modificação do eletrodo de carbono vítreo (CV) com o PBV sintetizado. Este método garantiu o controle da cobertura e a linearidade nas análises. Assim, o método foi padronizado com a aplicação de eletrólise por 30 s durante o terceiro ciclo em -0,4 V. A varredura adotada foi 50 mV s-1 de 0 a -0,8 V. Esse padrão forneceu de 2,0 a 3,0 nmol cm-2 de cobertura. O eletrodo CV-PBV não apresentou dificuldades na transferência de carga da superfície do eletrodo para o polímero, apesar do valor de k = 5,2 s-1 em tampão fosfato 0,1 mol L-1 pH 7,0. O valor do coeficiente difusional de cada fármaco foi determinado em tampão fosfato 0,1 mol L-1 pH 7,0. Os estudos de redução dos fármacos em diferentes pHs estão de acordo com o mecanismo descrito na literatura. Além disso, os resultados indicam que o eletrodo modificado diminui a influência do pH sobre a redução dos fármacos. As quantificações dos fármacos foram feitas por curvas padrões com os eletrodos CV e Au, polidos e modificados. As correntes foram lineares até a concentração de 120 mol L-1. A modificação do eletrodo de CV com o PBV diminuiu, no mínimo, em aprox. 80 mV o potencial de redução dos fármacos em pH 7,0 em relação ao eletrodo de CV polido. A exceção foi o eletrodo de ouro modificado (Au-PBV) na análise de Nimes. Pode-se ainda, atribuir à modificação do eletrodo com o PBV o aumento da sensibilidade das análises em comparação aos respectivos eletrodos polidos. Somente a determinação do NTZ não apresentou o mesmo efeito. O eletrodo CV-PBV foi empregado com sucesso na quantificação dos fármacos (NTZ, CNZ e Nimes) em amostras comerciais de Rivotril®, Sonebon® e Nimesulida - medicamento genérico. As quantificações apresentaram aproximadamente 100% de recuperação. A normalização das diferentes análises pelos valores das coberturas dos eletrodos mostrou uma curva analítica com boa correlação linear. Finalmente, os resultados apresentados neste trabalho sugerem a possibilidade de desenvolver eletrodos descartáveis. Estes eletrodos podem ser empregados na análise de substâncias utilizadas de forma ilícitas, neste caso, o coquetel chamado Boa noite Cinderela, para uso da perícia forense em análise amperométrica, no próprio local investigado. Estes eletrodos também podem ser aplicados nas indústrias farmacêuticas, nos setores de controle de qualidade de fármacos e medicamentos. / In health care, broadly administered drugs can be highlighted, which possess nitro group moieties within their molecules, such as the Clonazepam (CNZ), Nitrazepam (NTZ), and Nimesulide (Nimes). CNZ and NTZ are illicitly administered as part of narcotics drinks, weakening their victims. Nimes is an anti-inflammatory drug widely administered and often used in self-medication. Detection and quantification methods of these drugs are in the majority of cases costly and involve techniques such as HPLC, gas chromatography, etc. Only few studies have made use of electroanalytical determination, and among them, even fewer have made use of chemically modified electrodes (CME). CMEs improve selectivity and sensitivity of analysis. Among of modification methods, polymeric films are very versatile and make possible the development of specific electrodes. An important type of polymers comprise Viologen derivatives, such as Poly (benzyl viologen) (PBV). This polymer is used serving different purposes. This polymer has three oxidation states; one of them, PBV+, acts as a redox mediator. Also in addition, our group has provided evidence for the possibility of PBV+ to act reducing nitro compounds. In this way, in the present work it was determined the best experimental conditions for developing CME with PBV for further application in analysis and quantification of nitro derivative drugs (CNZ, NTZ and Nimes), as well as commercial samples, through the use of cyclic voltammetry technique. This work has contributed to the development of an effective methodology for the modification of glassy carbon (GC) electrodes with synthesized PBV. This method guaranteed the control of coverage and the linearity of the analysis. In this way, this method was standardized with a potential hold during the third cycle of about -0.4V for 30 sec. Scan rate of potential was 50 mV s-1, from 0 to -0.8 V. This method provided a coverage 2.0 to 3.0 nmol cm-2. The electrode GC-PBV did not show difficulties to charge transfer from the electrode surface to polymer, although the value of k was 5.2 s-1 in 0.1 mol L-1 phosphate buffer solution, pH 7.0. The difusional coefficient value of each drug was determined in 0.1 mol L-1 phosphate buffer solution, pH 7.0. Reduction studies of drugs in different pHs were in agreement with mechanisms described in the literature. Furthermore, results suggest that modified electrode decreased pH influence regarding drug reduction. Drug quantification was achieved from standard curves using GC and gold electrodes, polished and modified. Currents were linear up to 120 mol L-1. GC electrode modification with PBV decreased, at least, in approximately 80 mV, the drug potential reduction at pH 7.0 compared to respective polished electrode. The exception was found for gold modified electrode during Nimes analysis. It can be also attributed to modification with PBV the increase of analysis sensitivity when compared to respective polished electrodes. Only NTZ determination did not show the same effect. The GC-PBV was successfully employed for drug quantification (NTZ, CNZ and Nimes) from commercial samples, such as Rivotril®, Sonebon® and Nimesulide generic medicine. Drug quantification exhibited recovery close to 100%. Standardization of different analysis by electrode coverage value showed good linear correlation. Finally, results suggest the possibility to develop disposable electrodes. These electrodes can be employed to illicit substance analysis, in the present case, the narcotic drinks known in Brazil as Boa noite Cinderela, in addition to use in forensics during amperometic analysis at the site of investigation. Also, such electrodes could be used in pharmaceutical industries, for drug and medicine quality control.

Page generated in 0.067 seconds