• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 106
  • 9
  • Tagged with
  • 115
  • 115
  • 60
  • 27
  • 24
  • 21
  • 20
  • 19
  • 17
  • 17
  • 15
  • 15
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Monitoramento de saúde em sistema acionado por motor de corrente contínua sem escova

Carlos Gustavo Nuñez Rosa 22 April 2009 (has links)
O objetivo de estudo desta dissertação é apresentar uma metodologia para a realização de prognóstico e gerenciamento da saúde (Condition-Based Maintenance/Prognostic Health Management) de sistemas dinâmicos, assunto que vem crescendo de importância nas indústrias de forma global. O estudo de caso é realizado em um sistema de flap de uma aeronave regional acionado por motores CC sem escova, que foi modelado em MATLAB/SIMULINK. Através do modelo foi possível a realização do estudo de testabilidade e diagnosticabilidade das degradações e falhas do sistema e a implementação de técnicas de detecção de degradação através de controle estatístico de processo multivariável (MSPC), largamente utilizadas em diversas áreas da indústria. As técnicas de controle estatístico através de distâncias estatísticas, Hotelling';s T e Runger U, proporcionam uma medida de boa qualidade como mostrado nos resultados do estudo e pode ser usada para o prognóstico, como sugerido para trabalhos futuros.
102

Análise do fluxo de informação na melhoria do processo de desenvolvimento de novos produtos

Bonfim, Marcu Aurélio Loreto 02 December 2011 (has links)
Made available in DSpace on 2015-04-22T22:11:17Z (GMT). No. of bitstreams: 1 Marcu_Aurelio.pdf: 6856454 bytes, checksum: 8b0130e36bdbeac8f01f349628863ece (MD5) Previous issue date: 2011-12-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This research addresses the Products Development Process - (PDP) adopted in manufacturing companies of artifacts for mobile communication (cellular), installed in Manaus Industrial Pole (MIP), the research is focused on how companies deal with the introduction of a new product on the market and which information is to be used to improve its process and products. The work refers to the flow of information used in the process of introduction and analysis of failures of the products, in particular in relation to the monitoring process for new products, currently used in 02 (two) multinational companies. It raised issues regarding the monitoring of the quality of their products recently launched in the market and which analytical techniques are adopted, and the comprehensiveness of the same, as well as how the information reaches the department of new products, in each organization. This is a case study involving the processes of monitoring and analysis of failures in products on the market, and comparing the processes used in the surveyed companies, pointing out the main elements and contribution to the PDP model, as well as the strengths and weaknesses in each case. As a conclusion to the work, a theoretical model of information management as a complement to the current PDP model is presented, considering the experience acquired in 08 (eight) years of work in the areas of testing and analysis of failures in products and in the department of development of new products and software development. / O presente trabalho de pesquisa verse sobre o Processo de Desenvolvimento de Produtos (PDP) adotado em empresas manufatureiras de artefatos de comunicação móvel (celulares), instaladas no Pólo Industrial de Manaus (PIM), a pesquisa esta focada em como as empresas lidam com a introdução de um novo produto no mercado e quais informações são utilizadas para melhorias em seus processo e produtos. O trabalho refere-se ao fluxo de informações adotado no processo de introdução e analise de falhas dos produtos, em especial no que se refere ao processo de acompanhamento de novos produtos, atualmente utilizado nas 02 (duas) empresas multinacionais. Foram focados aspectos quanto ao monitoramento da qualidade de seus produtos recém lançados no mercado e quais técnicas de analise são adotadas e a abrangência das mesmas, assim como a informação chega ao departamento de novos produtos, em cada organização. Trata-se de um estudo de caso envolvendo os processos de acompanhamento e análise de falhas em produtos no mercado, comparando os processos utilizados nas empresas pesquisadas, apontando os principais elementos e contribuição para o modelo PDP, assim como os pontos fortes e fracos em cada processo. Como conclusão do trabalho, é apresentado um modelo teórico de gestão da informação como complemento ao atual modelo PDP, considerando-se a experiência adquirida em 08 (oito) anos de trabalho nas áreas de teste e analise de falhas em produtos e no departamento de desenvolvimento de novos produtos e desenvolvimento de software.
103

Proposta de um novo método para a detecção de barras rompidas em motores de indução com rotor em gaiola. / The proposal of a new method for thedetection of broken bars in squirrel cage induction.

Cleber Gustavo Dias 28 June 2006 (has links)
O estudo das condições de operação de um motor de indução em um ambiente industrial é indispensável, tendo em vista que eventuais problemas podem contribuir para um prejuízo na produção, ou ainda para custos adicionais relacionados à falta de manutenção dos equipamentos. Uma das principais falhas que podem ocorrer em um motor de indução do tipo gaiola de esquilo durante sua operação é o rompimento de uma ou mais barras que compõem o seu rotor. Apresenta-se neste trabalho um novo método para auxiliar na detecção de barras quebradas em um rotor tipo gaiola de esquilo, para um motor de grande porte, durante sua operação em regime permanente. A partir de um modelo matemático foi possível avaliar o rompimento de barras do rotor, detectando em uma posição específica, a variação da densidade de fluxo magnético resultante, produzida pela contribuição do fluxo de dispersão de cada barra do rotor, bem como pelo fluxo criado pelas correntes do estator. Um sensor de efeito Hall é instalado entre duas bobinas do estator, a fim de representar a posição onde é realizado o cálculo da densidade de fluxo magnético resultante pela modelagem matemática proposta. O sinal gerado pelo sensor a partir de uma falha é comparado com aquele obtido a partir do rotor saudável, para posterior análise. O trabalho sugere ainda a aplicação do método de detecção da falha em conjunto com uma técnica de inteligência artificial baseada nas redes neurais artificiais, a fim de contribuir para o diagnóstico da falha e estimativa do número de barras rompidas. Os resultados obtidos da simulação, bem como os dados obtidos durante o ensaio são apresentados e usados na validação do modelo matemático desenvolvido. / The study of operational conditions of an induction motor in an industrial environment is indispensable, once eventual problems can contribute for production losses, or still for additional costs related to the lack of equipments maintenance. Among the principal faults, in a squirrel cage induction motor can occur the breaking of one or more rotor bars. This work presents a new method in aid of detection of broken bars in a large squirrel cage induction motor during its operation in steady-state. A mathematical model is used to evaluate the broken rotor bars, detecting in a specific point, the resulting magnetic flux density produced by the leakage flux created by the rotor and stator currents. The Hall effect sensor is installed between two stator coils, in order to represent the position where the resulting magnetic flux density is calculated by the proposed mathematical model. The signal detected in the sensor during a fault, is compared to the obtained result of the magnetic flux density from a healthy rotor for analysis. The work still suggests the application of the artificial intelligence technique, based on artificial neural networks in the mathematical model, in order to aid on the fault detection and estimate of the number of broken bars. The simulation and experimental results are presented in order to validate the developed mathematical model.
104

Localização de faltas em alimentadores primários de distribuição de energia com a presença da geração distribuída

Nunes, José Ubirajara Nuñez de January 2010 (has links)
A automatização dos sistemas de distribuição de energia e a integração de energias renováveis são duas importantes iniciativas atuais em sistemas elétricos de potência. A redução no impacto ambiental e o baixo custo comparado às grandes plantas convencionais são fatores que motivam a conexão da geração distribuída nos sistemas de distribuição. Apesar dos benefícios ambientais e econômicos obtidos com esta nova tecnologia, esta pode influenciar na operação do sistema, conduzindo a impactos técnicos que devem ser identificados. O impacto mais visível encontra-se na alteração do fluxo de potência. O alto nível de geração distribuída altera a natureza das redes de distribuição, de redes passivas, com um único sentido de fluxo de potência, para redes ativas, onde a potência flui em vários sentidos. Por conseqüência, a magnitude e a direção das correntes de falta no sistema também são modificadas. Este fato requer um ajuste dos sistemas de proteção, os quais são geralmente concebidos para operar em uma rede puramente passiva. Diversas abordagens sobre localização de faltas fundamentadas na impedância para sistemas radiais foram apresentadas em anos recentes na literatura. Estas técnicas apresentam limitações quando aplicadas a sistemas de distribuição com a presença da geração distribuída. Algumas técnicas de localização de faltas fundamentadas na impedância de seqüência positiva foram recentemente desenvolvidas a fim de incluir a presença da geração distribuída. No entanto, os sistemas de distribuição são inerentemente desequilibrados e esta característica diminui a exatidão das técnicas baseadas nas componentes modais ou de seqüência. Motivado por estes fatos, o presente trabalho ilustra os desenvolvimentos propostos em uma metodologia de localização de faltas baseada na impedância aparente utilizando a representação do sistema por coordenadas de fase. O algoritmo propõe um modelo ativo do sistema caso a falta ocorra a montante da geração distribuída, estimando a contribuição de corrente da extremidade remota da seção faltosa. Além disso, este trabalho fundamenta-se na análise pré-falta do sistema, utilizada para a determinação das impedâncias equivalentes e para a estimativa da tensão interna da máquina. O método considera a tensão interna da máquina constante entre os períodos pré-falta e durante a falta, a fim de estimar a corrente de falta do gerador, possibilitando a atualização correta das tensões e correntes faltosas do sistema. A análise numérica é realizada através de simulações computacionais em um alimentador teste sem a presença de ramificações laterais sob diferentes níveis de geração distribuída. Os resultados são comparados com técnicas atuais que compõem o estado da arte de localização de faltas a fim de avaliar o impacto da geração distribuída nas referidas metodologias. Com base nesses resultados é possível apresentar algumas melhorias obtidas através das extensões propostas. / The automation for power distribution systems and integration of renewable energy are two important current initiatives on electric power systems. The reduction in environmental impact and low cost compared to large conventional plants are factors that motivate the connection of distributed generation in distribution systems. Despite the environmental and economic benefits obtained with this new technology, this can affect the system operation, leading to technical impacts to be identified. The most visible impact is the change in the power flow. The high level of distributed generation changes the nature of distribution networks, from passive networks with a single direction of power flow, for active networks, where power flows in various directions. Consequently, the magnitude and direction of fault currents in the system are also modified. This requires an adjustment of the protection systems, which are generally designed to operate in a purely passive network. Several approaches to fault location based on impedance to radial systems were reported in the literature. These techniques have limitations when applied to distributed generation systems. Some recent positive-sequence impedance based fault location algorithms have been developed to consider the presence of distributed generation. However, the distribution systems are inherently unbalanced and this reduces the accuracy of modal or sequence components based techniques. Motivated by these, this presents proposed developments on a apparent impedance-based fault location methodology using the system representation by phase coordinates. The algorithm proposes an active system model if the failure occurs forward to the distributed generation, estimating the contribution of current from the remote end section of the fault. Moreover, this work is based on analysis of the pre-fault system, used to determine the equivalent impedances and to estimate the machine internal voltage. The method treats the machine internal voltage as constant between the pre and the fault period, in order to estimate the fault current infeed by generator. Numerical analysis is carried out through computer simulations on a test feeder without the presence of ramifications at different levels of distributed generation. The results are compared with current techniques that make up the state of the art of fault location in order to assess the impact of distributed generation in these methodologies. Based on these results it is possible to make some improvements resulting from the proposed extensions.
105

Diagnóstico de faltas em sistemas de subtransmissão : uma formulação baseada na Transformada Wavelet contínua

Iurinic, Leonardo Ulises January 2012 (has links)
As faltas podem ocorrer em diversos componentes de um sistema elétrico de potência, dentre os quais as linhas de transmissão se destacam como elementos susceptíveis. Devido a suas dimensões físicas, ambiente de operação e interconexão com outros sistemas, a localização exata de uma falta em uma linha de transmissão não é trivial dificultando a tarefa das equipes de manutenção para recomposição do fornecimento de energia. Neste contexto, este trabalho apresenta uma metodologia computacional desenvolvida em ambiente MATLAB® para diagnóstico de faltas em linhas de transmissão baseada na análise de transitórios de alta freqüência nas tensões do sistema. A abordagem desenvolvida neste trabalho inicialmente utiliza a equação de Park para achar a tensão zero, direta e em quadratura e posteriormente detectar a ocorrência da falta através do coeficiente de diferenças. Posteriormente, a teoria de ondas viajantes associada à transformada wavelet contínua são utilizadas objetivando determinar a frequência característica do sinal transitório, a qual é relacionada com o local da falta. Para validar o algoritmo de localização proposto foram realizadas diversas simulações de faltas com o programa ATP (Alternative Transient Program) utilizando dados de uma linha aérea real. A efetividade da abordagem proposta foi avaliada considerando a resistência de falta, o ângulo de incidência da falta e a impedância de curto-circuito do sistema. Os resultados promissores demonstraram a aplicabilidade da formulação proposta para localização faltas em linhas de transmissão aéreas utilizando medições oscilográficas digitais de apenas um terminal. / Faults can occur in several components of an electric power system, among which the transmission line stands out. Due to its physical dimensions, operating environment and interconnection systems, the exact transmission line fault location is non-trivial hindering maintenance crew system restoration. In this context, this work presents a computational methodology developed in MATLAB® environment for fault diagnosis on transmission lines based on voltage high frequency transient analysis. Thus, the approach adopted in this work use firstly the Park equations to find the zero, direct and quadrature voltage and then detect the fault occurrence through the difference coefficient. After, the traveling wave theory associated with continuous wavelet transform application is used for determining the characteristic frequency of the transient signal, which is correlated with the fault location. To validate the proposed fault location algorithm, several fault simulations were executed using ATP software using real overhead line data. The proposed fault location scheme performance was evaluated considering the fault resistance, inception fault angle and short-circuit impedance of the system. The promising results demonstrate the applicability of the proposed formulation for fault location in overhead transmission lines, using one terminal digital oscillographic measurement.
106

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
107

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
108

Localização de faltas em alimentadores primários de distribuição de energia com a presença da geração distribuída

Nunes, José Ubirajara Nuñez de January 2010 (has links)
A automatização dos sistemas de distribuição de energia e a integração de energias renováveis são duas importantes iniciativas atuais em sistemas elétricos de potência. A redução no impacto ambiental e o baixo custo comparado às grandes plantas convencionais são fatores que motivam a conexão da geração distribuída nos sistemas de distribuição. Apesar dos benefícios ambientais e econômicos obtidos com esta nova tecnologia, esta pode influenciar na operação do sistema, conduzindo a impactos técnicos que devem ser identificados. O impacto mais visível encontra-se na alteração do fluxo de potência. O alto nível de geração distribuída altera a natureza das redes de distribuição, de redes passivas, com um único sentido de fluxo de potência, para redes ativas, onde a potência flui em vários sentidos. Por conseqüência, a magnitude e a direção das correntes de falta no sistema também são modificadas. Este fato requer um ajuste dos sistemas de proteção, os quais são geralmente concebidos para operar em uma rede puramente passiva. Diversas abordagens sobre localização de faltas fundamentadas na impedância para sistemas radiais foram apresentadas em anos recentes na literatura. Estas técnicas apresentam limitações quando aplicadas a sistemas de distribuição com a presença da geração distribuída. Algumas técnicas de localização de faltas fundamentadas na impedância de seqüência positiva foram recentemente desenvolvidas a fim de incluir a presença da geração distribuída. No entanto, os sistemas de distribuição são inerentemente desequilibrados e esta característica diminui a exatidão das técnicas baseadas nas componentes modais ou de seqüência. Motivado por estes fatos, o presente trabalho ilustra os desenvolvimentos propostos em uma metodologia de localização de faltas baseada na impedância aparente utilizando a representação do sistema por coordenadas de fase. O algoritmo propõe um modelo ativo do sistema caso a falta ocorra a montante da geração distribuída, estimando a contribuição de corrente da extremidade remota da seção faltosa. Além disso, este trabalho fundamenta-se na análise pré-falta do sistema, utilizada para a determinação das impedâncias equivalentes e para a estimativa da tensão interna da máquina. O método considera a tensão interna da máquina constante entre os períodos pré-falta e durante a falta, a fim de estimar a corrente de falta do gerador, possibilitando a atualização correta das tensões e correntes faltosas do sistema. A análise numérica é realizada através de simulações computacionais em um alimentador teste sem a presença de ramificações laterais sob diferentes níveis de geração distribuída. Os resultados são comparados com técnicas atuais que compõem o estado da arte de localização de faltas a fim de avaliar o impacto da geração distribuída nas referidas metodologias. Com base nesses resultados é possível apresentar algumas melhorias obtidas através das extensões propostas. / The automation for power distribution systems and integration of renewable energy are two important current initiatives on electric power systems. The reduction in environmental impact and low cost compared to large conventional plants are factors that motivate the connection of distributed generation in distribution systems. Despite the environmental and economic benefits obtained with this new technology, this can affect the system operation, leading to technical impacts to be identified. The most visible impact is the change in the power flow. The high level of distributed generation changes the nature of distribution networks, from passive networks with a single direction of power flow, for active networks, where power flows in various directions. Consequently, the magnitude and direction of fault currents in the system are also modified. This requires an adjustment of the protection systems, which are generally designed to operate in a purely passive network. Several approaches to fault location based on impedance to radial systems were reported in the literature. These techniques have limitations when applied to distributed generation systems. Some recent positive-sequence impedance based fault location algorithms have been developed to consider the presence of distributed generation. However, the distribution systems are inherently unbalanced and this reduces the accuracy of modal or sequence components based techniques. Motivated by these, this presents proposed developments on a apparent impedance-based fault location methodology using the system representation by phase coordinates. The algorithm proposes an active system model if the failure occurs forward to the distributed generation, estimating the contribution of current from the remote end section of the fault. Moreover, this work is based on analysis of the pre-fault system, used to determine the equivalent impedances and to estimate the machine internal voltage. The method treats the machine internal voltage as constant between the pre and the fault period, in order to estimate the fault current infeed by generator. Numerical analysis is carried out through computer simulations on a test feeder without the presence of ramifications at different levels of distributed generation. The results are compared with current techniques that make up the state of the art of fault location in order to assess the impact of distributed generation in these methodologies. Based on these results it is possible to make some improvements resulting from the proposed extensions.
109

Sistemática para avaliação de desempenho na prestação de serviços: o caso do processo de novas ligações em empresa de distribuição de energia elétrica

Araújo, Manuel Edervaldo Souto 26 September 2011 (has links)
Made available in DSpace on 2015-05-08T14:53:27Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2050762 bytes, checksum: d03ea0191257aa516c9df03c51af0335 (MD5) Previous issue date: 2011-09-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study proposes a systematic method for evaluating the performance of service delivery through process modeling and failure analysis. The implementation of the proposal took place in a distribution company of electricity (COELCE), in which he was elected New Process Connections as an object of study for the following reasons: This process helps to reduce the deficit of households without electricity in the country and showed a high rate of irregularities pointed out by regulators from providing that service here has to justify the choice of process and not the company. This is a case study, with secondary data were collected in books, websites, internal documents COELCE and scientific publications (journals, dissertations and theses). We obtained the primary data in reading and statistical analysis of company documents to the investigator assigned by the managers of the process, meetings with experts COELCE before, during and after field research, and intensive direct observation of the teams responsible for the physical connections of the units consumers. The methodology proposed by the tool is composed of colored Petri nets for modeling process New Links and techniques of failure analysis (FTA Fault Tree Analysis) and FMEA (Failure Mode and Effects Analysis). The systematic validation enabled: first - viewing different phases and activities of the process; second - identification of critical functions and potential failure of the process, the third - the formulation of action plan by the researcher to improve the process of New Connections. The action plan was endorsed by the group of experts COELCE, which collaborates with the research, from the exploratory phase. The use of integrated techniques proposed in this paper contributes to scientific knowledge by using the approach of process modeling and analysis techniques of failures in service businesses, especially in regard to the reduced number of work in this area. It is noteworthy that the systematics can be applied to other companies in the services sector can contribute in improving the performance of the processes analyzed. / Este estudo propõe uma sistemática para avaliar o desempenho da prestação de serviços por meio da modelagem de processos e análise de falha. A aplicação da proposta ocorreu em uma empresa de distribuição de energia elétrica (COELCE), na qual elegeu-se o Processo de Novas Ligações como objeto de estudo pelos seguintes motivos: esse processo contribui para reduzir o déficit de domicílios sem energia elétrica no país e apresentava elevado índice de irregularidades apontadas pelos órgãos reguladores da prestação desse serviço público. Trata-se de um estudo de caso cujos dados secundários foram coletados em livros, sites, documentos internos da COELCE e publicações científicas (periódicos, dissertações e teses). Obteve-se os dados primários em leitura e tratamento estatístico de documentos da empresa cedidos ao pesquisador pelos gestores do processo, reuniões com especialistas da COELCE, antes, durante e após pesquisa de campo, e observação direta intensiva das equipes responsáveis pelas ligações físicas das unidades consumidoras. A sistemática proposta é composta pela ferramenta redes de Petri Coloridas para modelagem do Processo de Novas Ligações e as técnicas de análise de falhas FTA (Fault Tree Analysis) e FMEA (Failure Mode and Effects Analysis). A validação da sistemática permitiu: primeiro - visualização de diferentes fases e atividades do processo; segundo identificação de funções críticas e falhas potenciais do processo; terceiro - formulação de plano de ação pelo pesquisador para melhoria do Processo de Novas Ligações. O plano de ação foi validado pelo grupo de especialistas da COELCE, que colabora com a pesquisa, desde a fase exploratória. A utilização das técnicas de forma integrada proposta neste trabalho contribui para o conhecimento científico por utilizar a abordagem de modelagem de processos e técnicas de análise de falhas em empresas de serviço, principalmente no que tange ao reduzido número de trabalho nesta área. Vale ressaltar que a sistemática pode ser aplicada em outras empresas do setor de serviços podendo contribuir na melhoria do desempenho dos processos analisados.
110

Diagnóstico de faltas em sistemas de subtransmissão : uma formulação baseada na Transformada Wavelet contínua

Iurinic, Leonardo Ulises January 2012 (has links)
As faltas podem ocorrer em diversos componentes de um sistema elétrico de potência, dentre os quais as linhas de transmissão se destacam como elementos susceptíveis. Devido a suas dimensões físicas, ambiente de operação e interconexão com outros sistemas, a localização exata de uma falta em uma linha de transmissão não é trivial dificultando a tarefa das equipes de manutenção para recomposição do fornecimento de energia. Neste contexto, este trabalho apresenta uma metodologia computacional desenvolvida em ambiente MATLAB® para diagnóstico de faltas em linhas de transmissão baseada na análise de transitórios de alta freqüência nas tensões do sistema. A abordagem desenvolvida neste trabalho inicialmente utiliza a equação de Park para achar a tensão zero, direta e em quadratura e posteriormente detectar a ocorrência da falta através do coeficiente de diferenças. Posteriormente, a teoria de ondas viajantes associada à transformada wavelet contínua são utilizadas objetivando determinar a frequência característica do sinal transitório, a qual é relacionada com o local da falta. Para validar o algoritmo de localização proposto foram realizadas diversas simulações de faltas com o programa ATP (Alternative Transient Program) utilizando dados de uma linha aérea real. A efetividade da abordagem proposta foi avaliada considerando a resistência de falta, o ângulo de incidência da falta e a impedância de curto-circuito do sistema. Os resultados promissores demonstraram a aplicabilidade da formulação proposta para localização faltas em linhas de transmissão aéreas utilizando medições oscilográficas digitais de apenas um terminal. / Faults can occur in several components of an electric power system, among which the transmission line stands out. Due to its physical dimensions, operating environment and interconnection systems, the exact transmission line fault location is non-trivial hindering maintenance crew system restoration. In this context, this work presents a computational methodology developed in MATLAB® environment for fault diagnosis on transmission lines based on voltage high frequency transient analysis. Thus, the approach adopted in this work use firstly the Park equations to find the zero, direct and quadrature voltage and then detect the fault occurrence through the difference coefficient. After, the traveling wave theory associated with continuous wavelet transform application is used for determining the characteristic frequency of the transient signal, which is correlated with the fault location. To validate the proposed fault location algorithm, several fault simulations were executed using ATP software using real overhead line data. The proposed fault location scheme performance was evaluated considering the fault resistance, inception fault angle and short-circuit impedance of the system. The promising results demonstrate the applicability of the proposed formulation for fault location in overhead transmission lines, using one terminal digital oscillographic measurement.

Page generated in 0.0608 seconds