1

Análise termobarométrica aplicada à decomposição do oxalato de cálcio hidratado.

CEVOLANI, M. B. 10 April 2017 (has links)
Made available in DSpace on 2018-08-01T21:59:22Z (GMT). No. of bitstreams: 1 tese_10940_Dissertação Messias Bicalho Cevolani.pdf: 9606488 bytes, checksum: d3a905de90140d93166c7de9e1064c85 (MD5) Previous issue date: 2017-04-10 / Este trabalho trata da caracterização da técnica de Análise Termobarométrica e aplicação à decomposição do Oxalato de Cálcio Monohidratado (CaC2O4.H2O), que é realizada em três etapas com produtos gasosos distintos. Com esta técnica é possível obter simultaneamente medidas diretas de temperatura e pressão durante o processo de tratamento térmico, que é realizado a volume constante dentro de uma ampola de quartzo. Consequentemente, a partir das medidas de pressão e temperatura foi possível identificar parâmetros termodinâmicos relacionados à transição de fase e conservação de energia como entalpia, entropia e energia livre de Gibbs. As amostras foram decompostas variando-se sistematicamente os parâmetros experimentais iniciais como a massa, taxa de aquecimento, temperatura final do tratamento térmico e pressão inicial. Os resultados obtidos permitiram a identificação e descrição de vários fenômenos físicos relacionados ao processo de decomposição do composto em questão. Foi possível identificar que o aumento da pressão deslocou a temperatura de transição da primeira e da terceira etapas para níveis mais elevados. Na segunda etapa de transição, o aumento da pressão fez a temperatura de transição deslocar-se para níveis mais baixos. Foi identificado que o aumento da pressão para cada etapa de transição é proporcional ao aumento da massa. Desta forma a variação da massa também desloca as temperaturas de transição das três etapas de decomposição. Através da análise das pressões iniciais de cada experimento foi possível identificar pequenas quantidades de H2O em forma de umidade nas amostras e no recipiente dedicado ao processo. A quantidade de H2O relativa a esta umidade é exponencial em relação à pressão inicial utilizada para fechamento das próprias ampolas. Neste trabalho também foi explorado algumas limitações da técnica de Análise Termobarométrica quando aplicada à decomposição do CaC2O4.H2O. Nesse sentido, a faixa de temperatura limitada a 800°C foi identificada como a mais adequada para a realização desse tipo de experimento.
2

Analisador de desfibriladores e cardioversores. / Defibrillator and cardioverter analyzer.

Conrado Almeida de Oliveira 21 December 2009 (has links)
A desfibrilação e a cardioversão elétricas são os procedimentos terapêuticos padrões para o tratamento, respectivamente, das arritmias de fibrilação e taquicardia ventricular. O funcionamento eficaz e seguro de desfibriladores e cardioversores requer uma manutenção preventiva e corretiva sendo, portanto, necessária uma avaliação freqüente do desempenho destes equipamentos. Esta avaliação deve incluir a medição das energias e das tensões e correntes de pico além do tempo de sincronismo para o caso de cardioversores, sendo normalmente realizada por dispositivos denominados analisador de desfibriladores e cardioversores. Para que um analisador de desfibriladores e cardioversores esteja apto a realizar os ensaios prescritos pelas Normas pertinentes, ele deve atender a varias condições, portanto, é necessário a determinação de uma especificação tida como minimamente desejável para um analisador de desfibriladores e cardioversores. Este trabalho descreve o desenvolvimento de um analisador de desfibriladores e cardioversores de fácil utilização e capaz de medir a energia entregue a uma resistência de 50 W, simulando a impedância transtorácica, além das tensões e correntes de pico, positiva e negativa. O analisador também engloba um simulador de ECG, com o qual também se pode realizar ensaios para a medição do tempo de sincronismo de um cardioversor. Uma avaliação do reconhecedor de ritmos de desfibriladores externos automáticos também pode ser realizada através da simulação de arritmias passíveis ou não de desfibrilação. A forma de onda do pulso desfibrilatório é apresentada em um display tipo LCD de 256 x 64 pontos e todos os parâmetros aferidos podem ser transmitidos a um computador por meio de uma interface serial RS-232. A avaliação das incertezas de medição do analisador foi realizada de acordo com documentos normativos e os resultados obtidos mostraram-se adequados às exigências de precisão determinadas pela Norma ANSI/AAMI: DF2, tendo apresentado uma incerteza expandida relativa para as medições de energia igual a 1,03% no pior caso. Os resultados obtidos para a capacidade do procedimento de calibração mostrou-se adequado para as especificações de um analisador de desfibriladores e cardioversores, tendo obtido como resultado, no pior caso, um índice de capacidade Cm igual a 2,82, que é bem superior a 1,0, limite mínimo para que o procedimento seja considerado capaz. Uma comparação do desempenho de outros seis analisadores com a especificação tida como minimamente desejada também foi realizada e demonstrou diversas deficiências desses analisadores. Uma comparação do desempenho de outros seis analisadores com a especificação tida como minimamente desejada também foi realizada e demonstrou diversas deficiências desses analisadores. / The electrical defibrillation and cardioversion are the standard therapeutic procedures for treatment of ventricular fibrillation and ventricular tachycardia arrhythmias, respectively. The effective and secure operation of defibrillators and cardioverter require preventive and corrective maintenance. Therefore, its necessary a frequent evaluation of the performance of these devices. This evaluation must include measuring the energy, peak voltage, peak currents and response time to synchronized discharge, and is usually done by devices called defibrillator and cardioverter analyzer. In order for a defibrillator analyzer to be capable to perform the tests required by relevant Standards, it must be in compliance with several conditions, therefore, it is necessary the determination of a minimum specification that is desirable for a defibrillator and cardioverter analyzer. This paper describes the development of a defibrillators and cardioverters analyzer that is easy to use and is capable of measuring the delivered energy to a 50W resistance, simulating the transthoracic impedance, and also the peak voltage and peak current, positive and negative. The analyzer also includes an ECG simulator which allows the performance of tests to measure the response time to synchronized discharge of a cardioverter. An evaluation of the rhythm recognition detector of automated external defibrillators can also be performed through the simulation of arrhythmias whether or not passives of defibrillation. The waveform of the pulse is presented in a LCD display of 256x 64 pixels and all parameters measured can be transmitted to a computer through a serial interface RS-232. The evaluation of the analyzer uncertainty in measurement was performed according to the prescriptions of normative documents and the results were in accordance with the accuracy prescriptions of the ANSI/AAMI: DF2 Standard, presenting an expanded relative uncertainty for the energy measurements equal to 1,03% for worst case. The results obtained for the capacity of the calibration process are appropriate for the specifications of a defibrillator and cardioverter analyzer, resulting, in the worst case, in an index of capacity Cm equal to 2,82, well above 1,0, the minimum value required to consider the procedure capable. A comparison of the performance of other six analyzers with the minimum specification that is desirable was also done and it demonstrated several deficiencies s with the analyzers.
3

Analisador de desfibriladores e cardioversores. / Defibrillator and cardioverter analyzer.

Oliveira, Conrado Almeida de 21 December 2009 (has links)
A desfibrilação e a cardioversão elétricas são os procedimentos terapêuticos padrões para o tratamento, respectivamente, das arritmias de fibrilação e taquicardia ventricular. O funcionamento eficaz e seguro de desfibriladores e cardioversores requer uma manutenção preventiva e corretiva sendo, portanto, necessária uma avaliação freqüente do desempenho destes equipamentos. Esta avaliação deve incluir a medição das energias e das tensões e correntes de pico além do tempo de sincronismo para o caso de cardioversores, sendo normalmente realizada por dispositivos denominados analisador de desfibriladores e cardioversores. Para que um analisador de desfibriladores e cardioversores esteja apto a realizar os ensaios prescritos pelas Normas pertinentes, ele deve atender a varias condições, portanto, é necessário a determinação de uma especificação tida como minimamente desejável para um analisador de desfibriladores e cardioversores. Este trabalho descreve o desenvolvimento de um analisador de desfibriladores e cardioversores de fácil utilização e capaz de medir a energia entregue a uma resistência de 50 W, simulando a impedância transtorácica, além das tensões e correntes de pico, positiva e negativa. O analisador também engloba um simulador de ECG, com o qual também se pode realizar ensaios para a medição do tempo de sincronismo de um cardioversor. Uma avaliação do reconhecedor de ritmos de desfibriladores externos automáticos também pode ser realizada através da simulação de arritmias passíveis ou não de desfibrilação. A forma de onda do pulso desfibrilatório é apresentada em um display tipo LCD de 256 x 64 pontos e todos os parâmetros aferidos podem ser transmitidos a um computador por meio de uma interface serial RS-232. A avaliação das incertezas de medição do analisador foi realizada de acordo com documentos normativos e os resultados obtidos mostraram-se adequados às exigências de precisão determinadas pela Norma ANSI/AAMI: DF2, tendo apresentado uma incerteza expandida relativa para as medições de energia igual a 1,03% no pior caso. Os resultados obtidos para a capacidade do procedimento de calibração mostrou-se adequado para as especificações de um analisador de desfibriladores e cardioversores, tendo obtido como resultado, no pior caso, um índice de capacidade Cm igual a 2,82, que é bem superior a 1,0, limite mínimo para que o procedimento seja considerado capaz. Uma comparação do desempenho de outros seis analisadores com a especificação tida como minimamente desejada também foi realizada e demonstrou diversas deficiências desses analisadores. Uma comparação do desempenho de outros seis analisadores com a especificação tida como minimamente desejada também foi realizada e demonstrou diversas deficiências desses analisadores. / The electrical defibrillation and cardioversion are the standard therapeutic procedures for treatment of ventricular fibrillation and ventricular tachycardia arrhythmias, respectively. The effective and secure operation of defibrillators and cardioverter require preventive and corrective maintenance. Therefore, its necessary a frequent evaluation of the performance of these devices. This evaluation must include measuring the energy, peak voltage, peak currents and response time to synchronized discharge, and is usually done by devices called defibrillator and cardioverter analyzer. In order for a defibrillator analyzer to be capable to perform the tests required by relevant Standards, it must be in compliance with several conditions, therefore, it is necessary the determination of a minimum specification that is desirable for a defibrillator and cardioverter analyzer. This paper describes the development of a defibrillators and cardioverters analyzer that is easy to use and is capable of measuring the delivered energy to a 50W resistance, simulating the transthoracic impedance, and also the peak voltage and peak current, positive and negative. The analyzer also includes an ECG simulator which allows the performance of tests to measure the response time to synchronized discharge of a cardioverter. An evaluation of the rhythm recognition detector of automated external defibrillators can also be performed through the simulation of arrhythmias whether or not passives of defibrillation. The waveform of the pulse is presented in a LCD display of 256x 64 pixels and all parameters measured can be transmitted to a computer through a serial interface RS-232. The evaluation of the analyzer uncertainty in measurement was performed according to the prescriptions of normative documents and the results were in accordance with the accuracy prescriptions of the ANSI/AAMI: DF2 Standard, presenting an expanded relative uncertainty for the energy measurements equal to 1,03% for worst case. The results obtained for the capacity of the calibration process are appropriate for the specifications of a defibrillator and cardioverter analyzer, resulting, in the worst case, in an index of capacity Cm equal to 2,82, well above 1,0, the minimum value required to consider the procedure capable. A comparison of the performance of other six analyzers with the minimum specification that is desirable was also done and it demonstrated several deficiencies s with the analyzers.
4

[en] ATCHIM: A TIMING ANALYZER FOR HIERARCHICAL AND MIXED-MODE CIRCUITS / [pt] ATCHIM: ANALISADOR DE TEMPOS PARA CIRCUITOS HIERÁRQUICOS E MODO-MISTO

GUSTAVO DE OLIVEIRA ANNARUMMA 09 September 2009 (has links)
[pt] A análise do comportamento de tempos é uma etapa fundamental do processo de validação de projetos de circuitos integrados. O objetivo deste trabalho é apresentar aspectos de verificação de projetos e propor uma abordagem para análise de tempos de circuitos integrados baseada nos conceitos de hierarquia de definição, modo-misto de representação e independência de tecnologia. Foi implementado um analisador de tempos, o TCHiM, cujas características são apresentadas. / [en] Timing analysis is a fundamental step for the validation of a integrated circuit design. In this work present some aspects of verification of designs and an propose an approach for a timing analyzer, based on the concepst of definition hierarchy, mixed-mode representation and technology independence. A prototype was implement and its caracteristics are presented.
5

Proposta de equipamento para medição dos fenômenos relativos à qualidade da energia elétrica utilizando conceitos de instrumentos virtuais / Power quality measuring equipment proposal based on virtual instruments conception

Matana, Gleison Melhado 15 April 2008 (has links)
Este trabalho apresenta um estudo da literatura pertinente sobre qualidade da energia elétrica. O estudo apresentado está baseado na evolução do tema em nível nacional e internacional, buscando explicar o conceito dos principais fenômenos e selecionar as recentes resoluções e normas que regem os princípios de medição e os limites dos distúrbios eletromagnéticos que os caracterizam. As normas da IEC foram selecionadas para a aplicação na construção de um protótipo de um medidor de qualidade da energia elétrica, onde o princípio construtivo é o de instrumento virtual por sua flexibilidade de arquitetura. A implementação do protótipo dá-se em um microcomputador padrão de mercado pelo software LabVIEW, através de vários módulos independentes para cada distúrbio a ser medido. Os resultados numéricos das simulações executadas frente a cada distúrbio, gerando comparações entre valores aplicados e valores medidos são apresentados em forma de tabelas com seus respectivos erros percentuais para cada grandeza de cada módulo. / This dissertation presents a study of existing literature about power quality. The study presented is based on a theme evolution in national and international environment, trying to explain the main phenomenon conceptions and select the most recent standards that rule the measurement conceptions and the electromagnetic disturbances limits that characterize it. The IEC standard were selected to build a prototype of a power quality measure device where the construction conception is a virtual instrument because it has a flexible architecture. The prototype implementation was made from a common computer by the LabVIEW software through some independent modules for each disturbance to be measured. The numerical results of executed simulations of each disturbance generating comparisons between applied values and measured values are presented as tables within their percentage error for each phenomenon of each module.
6

Efeito do ultrassom na extra??o e caracter?sticas do amido de car?-do-ar (Dioscorea bulbifera) / Effect Ultrasound on extraction and starch characteristics of yam (Dioscorea bulbifera)

Bernardo, Cristiany Oliveira 26 February 2016 (has links)
Submitted by Sandra Pereira (srpereira@ufrrj.br) on 2016-10-13T11:27:52Z No. of bitstreams: 1 2011 - Cristiany Oliveira Bernardo.pdf: 1740458 bytes, checksum: ae55b89b5f70448972ad5987c95450b1 (MD5) / Made available in DSpace on 2016-10-13T11:27:52Z (GMT). No. of bitstreams: 1 2011 - Cristiany Oliveira Bernardo.pdf: 1740458 bytes, checksum: ae55b89b5f70448972ad5987c95450b1 (MD5) Previous issue date: 2016-02-26 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Among the different possibilities of use in the food industry, ultrasound can be considered an alternative to substitute or reduce the use of chemicals in extraction processes or modification of starches. When used in the extraction, enables higher purity of the obtained starch. The starch-the-air yam has physical characteristics desirable for applications such as thickening agent or disintegrating tablet formulations, for example, however, this extraction is hindered by the presence starch mucilage this tubercle. The aim of this study was to review the effect of ultrasound on the extraction and modification of several starches, evaluate their use in starch extraction of yam and its impact on characteristics this starch. After evaluating the chemical composition of tubers, previously washed, peeled and crushed in a blender. Then the crushed sample subjected to ultrasound. Different times (3, 6 to 9 minutes) and amplitudes (12, 40 and 68%) were evaluated by the Box Benker experimental design, furthermore evaluated the control treatment (0% amplitude) and ?T6? (15 minutes, 70% amplitude), totaling 7 treatments (T1, T2, T3, T4, T5, T6 and control). After sonication, the suspension was filtered and the extraction continued by successive washings, centrifugation and drying in an oven. After evaluating the performance of the extraction, the different treatments were characterized by analysis of chemical composition, instrumental analysis of color, scanning electron microscopy, optical microscopy, particle size, pattern of crystallinity, swelling power and solubility, paste clarity, paste properties and thermal properties and absolute density. There was increase in yield of 29,85% (control) to 32,09%, when used longer time and amplitude (15 min and 70% amplitude). The ultrasound caused damage to the surface of starch and reduced starch crystallinity peak, characterized as type B. Additionally, increased swelling power and consequently the paste viscosity of some treatments. However, 15 minutes, 70% amplitude (T6), reduced the swelling power, the paste viscosity and paste clarity and increased the setback. Therefore, despite the small increase in yield, when used ultrasound during extraction, damage was caused in the structure of starch, as well as changes in its physical and chemical characteristics / Dentre as diferentes possibilidades de utiliza??o na ind?stria de alimentos, o ultrassom pode ser considerado uma alternativa para substituir ou reduzir a utiliza??o de subst?ncias qu?micas em processos de extra??o ou modifica??o de amidos. Quando utilizado na extra??o, possibilita maior pureza do amido obtido. O amido de car?-do-ar possui caracter?sticas f?sicas desej?veis para aplica??es como agente espessante ou desintegrante em formula??es de comprimidos, por exemplo. No entanto, a extra??o desse amido ? dificultada pela presen?a de mucilagem nesse tub?rculo. O objetivo do presente estudo foi revisar o efeito do ultrassom na extra??o e modifica??o de diversos amidos, como milho, arroz, mandioca, batata, entre outros, avaliar sua utiliza??o na extra??o do amido de car?-do-ar e seu impacto sobre as caracter?sticas desse amido. Ap?s avaliar a composi??o centesimal do car?-do-ar, o mesmo foi lavado, descascados e triturados em liquidificador. Em seguida a amostra triturada foi submetida ao ultrassom. Diferentes tempos (3, 6 e 9 minutos) e amplitudes (12, 40 e 68%) foram avaliados por meio do planejamento experimental Box Benker. Al?m desses foram avaliados os tratamentos controle (0% amplitude) e T6 (15 minutos, 70% amplitude), totalizando 7 tratamentos (T1, T2, T3, T4, T5, T6 e controle). A extra??o prosseguiu por meio de filtra??o, lavagens sucessivas, centrifuga??o e secagem em estufa. Ap?s avaliar o rendimento da extra??o, os diferentes tratamentos foram caracterizados por meio das an?lises de composi??o centesimal, an?lise instrumental de cor, poder de inchamento e solubilidade, claridade de pasta, determina??o das propriedades t?rmicas e propriedades de pasta, padr?o de cristalinidade, microscopia eletr?nica de varredura, microscopia ?ptica, determina??o do tamanho de part?cula e densidade absoluta do amido. Houve aumento do rendimento de 29,85% (controle) para 32,09%, quando utilizado o maior tempo e amplitude (15 min e 70% amplitude). O ultrassom provocou danos na superf?cie do amido e reduziu os picos de cristalinidade do amido, caracterizados como tipo B. Al?m disso, aumentou o poder de inchamento e consequentemente a viscosidade de pasta de alguns tratamentos. No entanto, 15 minutos e 70% de amplitude (T6), do tratamento com ultrassom, reduziu o poder de inchamento, a viscosidade de pasta e a claridade de pasta e aumentou a tend?ncia ? retrograda??o. Dessa forma, apesar do pequeno aumento do rendimento quando utilizado o ultrassom durante a extra??o, danos foram provocados na estrutura desse amido, assim como altera??es das suas caracter?sticas f?sico-qu?micas.
7

Analisador virtual para a determinação do teor dos contaminantes mapd em um reator tricklebed

Massa, Ana Rosa Caribé de Góes January 2017 (has links)
Submitted by Uillis de Assis Santos (uillis.assis@ufba.br) on 2018-01-26T13:26:54Z No. of bitstreams: 1 AnaRosaCaribédeGóesMassa_Dissertação-UFBA-Politécnica-EngenhariaIndustrial-2017.pdf: 4582890 bytes, checksum: 3c5c6099462e9b7f61ff397081c5dd6a (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2018-01-26T16:03:46Z (GMT) No. of bitstreams: 1 AnaRosaCaribédeGóesMassa_Dissertação-UFBA-Politécnica-EngenhariaIndustrial-2017.pdf: 4582890 bytes, checksum: 3c5c6099462e9b7f61ff397081c5dd6a (MD5) / Made available in DSpace on 2018-01-26T16:03:46Z (GMT). No. of bitstreams: 1 AnaRosaCaribédeGóesMassa_Dissertação-UFBA-Politécnica-EngenhariaIndustrial-2017.pdf: 4582890 bytes, checksum: 3c5c6099462e9b7f61ff397081c5dd6a (MD5) / Analisadores em linha fornecem uma resposta rápida de composição em comparação às análises laboratoriais. Porém, esses estão sujeitos a frequentes interferências e contaminações devido às substâncias utilizadas nas correntes reais, que agridem, contaminam e comprometem o funcionamento do equipamento, exigindo manutenções rotineiras. Durante estas, há perda de informações vitais que podem culminar numa parada da produção, a não ser que outro equipamento permita estimar tais informações de maneira confiável. Desta forma, o presente trabalho tem por objetivo desenvolver um analisador virtual para estimar a concentração dos contaminantes metilacetileno e propadieno (MAPD) em um reator trickle bed em uma indústria de propileno no Brasil. A partir da coleta de dados de processos de uma campanha catalítica, coletados por cromatógrafos a gás, termopares e medidores de vazão, foram desenvolvidos modelos de calibração multivariada utilizando a técnica de Regressão por Mínimos Quadrados Parciais (PLS), para dois leitos catalíticos, A e B. Dados de treze variáveis de processo, monitoradas a cada 10 minutos durante uma campanha catalítica para cada leito, foram utilizados. Os modelos PLS foram desenvolvidos e validados e foram capazes de fornecer valores preditos confiáveis, com R2 de 0,84 para o leito A e 0,92 para o leito B. Normalidade e homocedacidade dos resíduos foram observadas em ambos modelos. Além disso, foi realizada uma seleção de variáveis utilizando o gráfico de escores VIP (Variable Importance in Projection) obtido durante o desenvolvimento dos modelos PLS. As variáveis mais importantes foram selecionadas e os modelos PLS construídos apenas com essas variáveis mantiveram a capacidade de predição em ambos os leitos, com valores de R2 de 0,82 para o leito A e 0,87 para o leito B. Normalidade e homocedacidade dos resíduos foram mantidas, e um teste F não gerou evidência que indicasse diferença significativa entre os modelos desenvolvidos antes e após a seleção de variáveis. Dessa forma, os modelos PLSVIP fornecem uma estimativa confiável do teor de MAPD no reator trickle bed na planta de propeno estudada. Esses resultados mostraram que os métodos desenvolvidos possuem um alto potencial de aplicação nos reatores estudados caso haja necessidade, evitando assim uma parada da planta e subsequente perda de capital investido. / Online analysers grant a faster answer on the composition of products when compared with laboratory analysis. However, the former is often affected by substances in the stream line which harm and compromise its normal working state, calling for frequent maintenance. During those, the loss of vital information could lead to a halt in production, unless another device allows for such information to be carefully estimated.As such, this paper aims at developing a Virtual Analyser that can estimate the concentration of methylacetylene and propadiene (MAPD) contaminants in a trickle bed reactor at a propene industrial plant in Brazil. Process data collected in the reactor by gas chromatographers,temperature probes and flowmeters were employed to build multivariate calibration models by using the Partial Least Square Regression(PLS)technique, for two bed reactors, A and B.Data from thirteen process variables, monitored every 10 minutes during one catalytic campaign for each bed, of about three months each, were used. The developed PLS models for both beds have shown a great prediction capacity and remarkable performances, with R2 of 0.84 for bed A and 0.92 for bed B. Residual normality and homoscedasticity were observed for both models. In addition, a variable selection approach was carried out using the VIP (Variable Importance in Projection) score plot obtained during the developed PLS models. The most important variables (process variables)were selected and the PLS models built with only these variables were still able to keep are markable prediction ability for both beds, with a R2 of 0.82 for bed A and 0.87 for bed B. Residual normality and homoscedasticity were kept, and an F test did not provide evidence for significant difference between the models developed before and after the variable selection. Therefore, the PLS-VIP models provided a reliable estimate of the MAPD content in the trickle bed reactors at the studied propene plant. These outcomes showed that the developed methods present a high potential for application in the studied reactors, if necessary, in order to prevent a halt in production and its subsequent loss of invested capital.
8

Aplicação de descritores topológicos e modelos estatísticos para o descobrimento de potenciais antagonistas da integrina alfa4 beta1 / Topological descriptors and statistical models applied to the discovery of potential alpha4 beta1 integrin antagonists

Silva, Gilberto Ferreira da January 2012 (has links)
Submitted by Alessandra Portugal (alessandradf@ioc.fiocruz.br) on 2013-09-24T19:31:30Z No. of bitstreams: 1 Gilberto Ferreira da Silva_Tese.pdf: 10525757 bytes, checksum: fed4f4587ca5231f5b7517d0ec5bee91 (MD5) / Made available in DSpace on 2013-09-24T19:31:30Z (GMT). No. of bitstreams: 1 Gilberto Ferreira da Silva_Tese.pdf: 10525757 bytes, checksum: fed4f4587ca5231f5b7517d0ec5bee91 (MD5) Previous issue date: 2012 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Vice Direção de Ensino, Informação e Comunicação. Rio de Janeiro, RJ, Brasil. / Doenças autoimunes abrangem uma grande variedade de desordens inflamatórias, até hoje consideradas incuráveis, tais como Artrite Reumatoide, Asma, Colite Ulcerativa, Doença de Crohn, Esclerose Múltipla, Hepatite Autoimune, e outras. Elas são caracterizadas pelo acúmulo exagerado e desmotivado de leucócitos em alguns órgãos, atacando células sadias do próprio organismo, lesionando e destruindo tecidos importantes. As integrinas, receptores glicoproteínicos expressos na superfície dos leucócitos, têm papel importante nesse processo: elas modulam a adesão dos leucócitos através da interação com seus ligantes primários, VCAMs (Vascular Cell Adhesion Molecules), expressos no tecido afetado. A interação integrina/ligante é que viabiliza a migração do leucócito do vaso sanguíneo para o interior do tecido. Sendo assim, uma alternativa terapêutica promissora, ainda sob investigação, para essas doenças é a administração de antagonistas, moléculas que tenham afinidade pelas integrinas de modo a se ligar a elas preferencialmente aos ligantes primários, dessa maneira inibindo a passagem dos leucócitos para o sítio da inflamação. No caso de Artrite Reumatoide, Asma e Esclerose Múltipla, a integrina de maior importância é a α4β1, para a qual uma boa quantidade de antagonistas já foi identificada. Infelizmente, porém, por variados motivos, nenhuma dessas drogas tem viabilidade para aplicação a seres humanos. Um indicador quantitativo da capacidade, exibida por uma droga, de inibir determinado processo biológico ou bioquímico é o índice IC50, definido pelo FDA como "a concentração (dessa droga) requerida para a inibição de 50% do processo in vitro". A partir, pois, de uma lista, compilada da literatura, de moléculas com capacidade, já experimentalmente quantificada, de antagonismo à integrina α4β1, nós participamos da busca de novos antagonistas construindo e aplicando modelos estatísticos de estimativa do índice IC50 para novas moléculas. As ferramentas que usamos são oriundas da Topologia Molecular, um campo de pesquisas da Teoria dos Grafos em Química, que busca inferir quantitativamente características importantes das moléculas a partir da topologia (vértices, arestas, adjacências, etc.) de grafos correspondentes a essas moléculas. / Autoimmune diseases cover a large variety of inflammatory disorders like Rheumatoid Arthritis, Asthma, Ulcerative Colitis, Crohn Disease, Multiple Sclerosis, Autoimmune Hepatitis, and others. To date, all them seem to be incurable. They are characterized by excessive and unnecessary accumulation of leukocytes in healthy organs, attacking the body's own healthy cells, injuring and destroying important tissues. Integrins, glycoprotein receptors expressed on the surface of leukocytes, play an important role in this process: they modulate leukocyte adhesion and migration from the blood vessel into the tissue through interaction with its ligands primary VCAMs (Vascular Cell Adhesion Molecules), expressed in the affected tissue. Thus, a promising alternative treatment for those diseases, still under investigation, is the administration of antagonists: molecules that bind to integrins with affinity comparable to that of their primary ligands, thereby inhibiting the migration of leukocytes to the site of inflammation. For rheumatoid arthritis, asthma and multiple sclerosis, the most important integrin is α4β1, for which several antagonists have been identified and published. Unfortunately, for various reasons, none of these drugs is feasible for application to humans; this way, the search for new antagonists is still active. A quantitative indicator of the ability of a drug to inhibit a biological or biochemical process is the IC50 index, defined by the FDA as "the concentration (of the drug) required for 50% inhibition of process in vitro". We perform participate in the search for new α4β1 antagonists by: starting with a list of antagonists compiled from the literature with their experimentally evaluated IC50 evaluated experimentally compiled from the literature, we build and apply statistical models to estimate the IC50 index for new molecules. We use tools derived from molecular topology, a research field of research of Chemical Graph Theory, which aims to infer quantitatively important characteristics of the molecules from the topology (vertices, edges, adjacencies , etc.) of the graphs corresponding to these molecules.
9

Caracterização do conteúdo harmônico em ambientes residenciais: estudo de caso / Characterization of harmonic content in residential environments: case study.

Carvalho, Flavio Gomes de 26 February 2015 (has links)
Submitted by Maria Suzana Diniz (msuzanad@hotmail.com) on 2015-11-06T13:34:11Z No. of bitstreams: 1 arquivototal.pdf: 8252204 bytes, checksum: ee6c84ddd82f31470862718d3b1b3abc (MD5) / Made available in DSpace on 2015-11-06T13:34:11Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 8252204 bytes, checksum: ee6c84ddd82f31470862718d3b1b3abc (MD5) Previous issue date: 2015-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work a characterization of harmonic content in residential electrical systems through a set of measurements over various periods of time is performed. For each reported case it was a statement of charges that make up the installation and an individual analysis of each of them as a way to assess their influence on the harmonic behavior of the installation as a whole. / Neste trabalho é realizada uma caracterização do conteúdo harmônico em instalações elétricas residenciais por meio de um conjunto de medições realizadas por diversos períodos de tempo. Para cada caso avaliado fez-se um levantamento das cargas que compõem a instalação e uma análise individual de cada uma delas como forma de avaliar sua influência no comportamento harmônico da instalação como um todo.
10

Levantamento de harmônicas em redes de distribuição de uma concessionária de energia / Harmonic Survey on Distribution Network of Concessionaire Energy

Pinto, Leandro Mayron de Oliveira 27 July 2016 (has links)
Submitted by Cristhiane Guerra (cristhiane.guerra@gmail.com) on 2017-01-26T15:09:50Z No. of bitstreams: 1 arquivototal.pdf: 2406047 bytes, checksum: 59f32e05e759280c4daa39da945d2707 (MD5) / Made available in DSpace on 2017-01-26T15:09:50Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2406047 bytes, checksum: 59f32e05e759280c4daa39da945d2707 (MD5) Previous issue date: 2016-07-27 / To know the disorders that affect the distribution networks originating from a power utility consumers and its evolution to the power substations, comparing measurements with literature and standards exercise. Material and Methods: We conducted three stages of measurement and analysis, using a three-phase digital analyzer, was measured the harmonic profile in different feeders of a substation for seven days each, then held the same measurement in a single residence and then this residence investigated the generators appliance harmonics. Results: In the first step, measuring feeders, they had low THD's voltage and current within the limits of standard, single-family residence already had maximum voltage THD equal to 2.84 and a maximum THD current 28.7. There was predominance of 3rd and 5th harmonic voltage and the 3rd, 5th and 7th harmonic current, with a few moments of supremacy of the 2nd harmonic. Investigating the appliance, the less power with switching power supplies introduces the greatest amount of harmonics on the network. Conclusion: distribution transformers filter low voltage harmonics, serving as a barrier to the medium voltage, which were not detected significant harmonics. The measurements reveal that in any case there was a violation of the voltage THD, in either whole or individual above the limits established by regulation, yet for the current THD presented several times above acceptable limits when analyzing the low voltage. The study shows that for power substation harmonic consumers do not evolve to the middle / high voltage. / Conhecer os distúrbios, originados dos consumidores, que acometem as redes de distribuição de uma concessionária de energia, bem como sua evolução até as subestações de energia, comparando, ainda, as medições com a literatura e as normas em exercício. Material e Método: Foram realizados três estágios de medições e análises, utilizando-se um analisador digital trifásico. Mediu-se o perfil de harmônicas em diferentes alimentadores de uma subestação, durante sete dias cada um, posteriormente realizou-se a mesma medição em uma única residência e em seguida, investigou-se, nessa mesma residência, os eletrodomésticos geradores de harmônicas. Resultados: Na primeira etapa, a medição dos alimentadores apresentou baixos THD’s de tensão e corrente dentro dos limites em norma; já a residência unifamiliar apresentou THD máximo de tensão igual a 2,84 e um THD máximo de corrente de 28,7. Observou-se predominância das 3ª e 5ª harmônicas de tensão e das 3ª, 5ª e 7ª harmônicas de corrente, com alguns momentos de supremacia da 2ª harmônica. Investigando os eletrodomésticos, constatou-se que os de menor potência com fontes chaveadas introduzem a maior quantidade de harmônicas na rede. Conclusão: Os transformadores de distribuição filtram as harmônicas de baixa tensão, servindo como uma barreira para a média tensão, onde não foram detectadas harmônicas consideráveis. As medições revelam que em nenhum caso houve violação do THD de tensão, nem total nem individual, acima dos limites estabelecidos por norma. Contudo, o THD de corrente apresentou diversos momentos acima dos limites aceitáveis quando analisada a baixa tensão. O estudo demonstra que, na subestação de energia, as harmônicas dos consumidores não evoluem até a média/alta tensão.