• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 6
  • Tagged with
  • 13
  • 13
  • 13
  • 7
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cellular and molecular mechanisms in abdominal aortic aneurysm growth and rupture /

Monsur, Kazi, January 2005 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2005. / Härtill 4 uppsatser.
2

Abdominal aortic aneurysm : experience from a screening study in Northern Sweden /

Wanhainen, Anders, January 2004 (has links)
Diss. (sammanfattning) Uppsala : Univ., 2004. / Härtill 5 uppsatser.
3

Co-stimulatory molecules : genes to protein in autoimmune and inflammatory disorders /

Sakthivel, Priya, January 2007 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2007. / Härtill 4 uppsatser.
4

Volume imaging of the abdomen : three-dimensional visualisation of tubular structures in the body with CT and MRI /

Persson, Anders, January 2005 (has links) (PDF)
Diss. Linköping : Linköpings universitet, 2005.
5

Cost-effectiveness and value of further research of treatment strategies for cardiovascular disease /

Henriksson, Martin, January 2007 (has links)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2007. / Härtill 5 uppsatser.
6

Análise funcional do endotélio no perioperatório de operações vasculares / Perioperative evaluation of endothelial function in patients undergoing vascular surgery

Calderaro, Daniela 09 April 2008 (has links)
Apesar dos grandes avanços na medicina perioperatória, as operações vasculares ainda estão associadas a elevada morbi-mortalidade. A fisiopatologia dos eventos perioperatórios é complexa, envolvendo a instabilização de placas ateroscleróticas, o que não é contemplado nos algoritmos para estratificação de risco cardíaco perioperatório. Acreditamos que a identificação de características relacionadas à instabilização de placas incipientes, como alterações na reatividade vascular e maior atividade inflamatória, pode melhorar a acurácia da estimativa de risco e a análise do comportamento perioperatório destas características pode elucidar importantes mecanismos fisiopatológicos. Estudamos 100 pacientes com indicação de operação vascular e aferimos por meio de ultrassom-Doppler de artéria braquial, a hiperemia reativa (HR), marcador de função microvascular, e a dilatação mediada pelo fluxo (DMF), marcador de função endotelial, antes e após a operação. Analisamos também os níveis de proteina-C reativa ultra-sensível (PCR-us). A operação foi realizada em 96 pacientes e 27 deles apresentaram algum evento até o 30º dia pós-operatório: 4 óbitos cardíacos, 5 infartos agudos do miocárdio, 2 acidentes vasculares cerebrais isquêmicos, 2 elevações isoladas de troponina, 1 embolia de pulmão, 2 reoperações e 11 óbitos não cardíacos. Detectamos disfunção endotelial em 70% dos pacientes, mas não observamos nenhum padrão característico de comportamento perioperatório da DMF, ou associação significativa entre a mesma e os eventos. Observamos significativo aumento da PCR-us após a intervenção cirúrgica (0,5mg/dL x 3,01mg/dL, P=0,001), mas sem associação com eventos. Identificamos forte associação entre disfunção microvascular, representada pela menor velocidade de fluxo na artéria braquial durante a hiperemia reativa, e eventos: 81 cm/s + 20 x 95 cm/s + 28 ( P= 0,02). Concluímos que a identificação de disfunção microvascular no pré-operatório pode estratificar o risco de complicações perioperatórias e que embora não tenhamos observado piora da vasodilatação mediada pelo fluxo, não podemos afastar que haja piora da função endotelial no perioperatório. O aumento de PCR-us denota grande diátese inflamatória, que pode estar relacionada à disfunção endotelial. / Despite great advances in perioperative care, major vascular surgeries are still related to high morbidity and mortality. The pathophysiology of perioperative cardiac events is complex and comprehends atherosclerotic plaque instability, witch is not contemplated in the current algorithms for cardiac risk estimation. We hypothesized that the identification of characteristics related to predisposition for plaque instability, such as abnormalities in the vascular reactivity, is very promising and the characterization of this parameter`s behavior in the perioperative setting contributes to the better understanding of event\'s pathophysiology. We prospectively studied a cohort of 100 patients, candidates for elective major vascular surgery and assessed, by Doppler ultrasound in the brachial artery, reactive hyperemia(RH), a marker of microvascular function, and flow mediated dilation(FMD), a marker of endothelial function, before and after surgery. We also obtained C-reactive protein-high sensitive assay (CRP-hs) before and after surgery. Ninety six patients were submitted to the planned vascular surgery and 27 patients had an event up to the 30º postoperative day. We observed 4 cardiac deaths, 5 acute myocardial infarctions, 2 isolated troponin elevations, 2 ischemic strokes, 1 pulmonary embolism, 2 reoperations and 11 noncardiac deaths. Results: although there was no significant difference in the preoperative FMD between patients with and without events: 4.83% + 6.81 x 5.88% + 6.00 (p= .457), respectively, low RH response, measured as lower peak flow velocity in RH, was associated to events: 81 cm/s + 20 x 95 cm/s + 28 (p=0,02). There was no significant difference in the preoperative CRP-hs between groups (median: 0.51mg/dL (IQR 2.12) x 0.41mg/dL (IQR 0.59), p= .234). There was no significant difference between FMD before and after surgery but we detected an almost 6-fold increase in CRP-hs after surgery: 0.50mg/dL x 3.01mg/dL (p < .001), respectively. Our study demonstrated that microvascular dysfunction is closely related to perioperative events after major vascular surgery and is a better marker of perioperative risk than endothelial dysfunction, in specific conditions.
7

Análise biomecânica e histológica do colo do aneurisma da aorta abdominal infrarrenal: estudo em necrópsia / Biomechanical and histological analysis of the infrarenal abdominal aortic aneurysm neck: a necropsy study

Queiroz, Andre Brito 04 November 2015 (has links)
INTRODUÇÃO: O colo dos aneurismas da aorta abdominal infrarrenal é o principal local de interação entre a parede aórtica e as próteses utilizadas no seu tratamento, pela técnica aberta ou endovascular. A dilatação do colo no acompanhamento pósoperatório, levando a falhas no tratamento, demonstra a importância de um colo confiável para um reparo eficiente em longo prazo. OBJETIVOS: Determinar as propriedades biomecânicas e histológicas do colo do aneurisma da aorta abdominal infrarrenal, comparando os resultados com as propriedades da aorta suprarrenal e da parede anterior do aneurisma. MÉTODOS: Dezesseis aneurismas da aorta abdominal infrarrenal encontrados em necrópsia foram removidos e dissecados em laboratório. A anatomia original dos aneurismas foi restabelecida com o auxílio de um balão complacente inserido na luz dos espécimes, sendo que aneurismas com um colo mais curto que 10 mm foram excluídos. Fragmentos transversais similares da parede anterior do aneurisma, do colo e da aorta suprarrenal foram obtidos com o auxílio de um dispositivo de corte apropriado. Testes de tração uniaxiais destrutivos foram realizados para a obtenção das seguintes propriedades biomecânicas: tensão, estresse, energia de deformação e deformação no momento da falência, além da medida da espessura dos fragmentos. A análise histológica destes fragmentos consistiu na quantificação das fibras colágenas, elásticas e espessura da camada média. RESULTADOS: Em doze aneurismas rotos e quatro não rotos, a análise biomecânica dos fragmentos de tecido arterial não demonstrou diferenças estatisticamente significativas entre os valores médios das propriedades biomecânicas de falência (tensão, estresse, energia de deformação e deformação), assim como para a espessura nos três segmentos estudados. O percentual de colágeno para o colo foi significativamente menor que na parede dos aneurismas (p = 0,010) e não foi significativamente diferente da aorta suprarrenal (p = 0,155). A elastina apresentou percentual significativamente maior no colo (p < 0,001) e na aorta suprarrenal (p < 0,001) quando comparados aos aneurismas. Não houve diferença na quantificação da elastina entre o colo e o segmento suprarrenal (p = 0,457). A espessura da camada média não apresentou diferença estatística relevante entre as três regiões avaliadas (p = 0,660). CONCLUSÕES: Os resultados biomecânicos sugerem que o aneurisma da aorta infrarrenal, ao invés de uma processo localizado, seja resultado de um acometimento aórtico difuso. Tanto a resistência quanto a elasticidade do segmento aneurismático apresentam semelhanças quando comparados aos segmentos aórticos não dilatados. Na análise histológica, nota-se preservação da elastina nos segmentos aórticos não dilatados, enquanto há redução na parede aneurismática; além de maior deposição de colágeno nesta região / INTRODUCTION: The neck of the infrarenal abdominal aortic aneurysm is the principal site of interaction between the aortic wall and the devices used in the repair of these aneurysms, by open or endovascular technique. Postoperative aneurysm neck dilation leading to aneurysm exclusion failures demonstrates the importance of a reliable neck for the long-term efficient repair. OBJECTIVE: To access the biomechanical and histological properties of the infrarenal aortic aneurysm neck, comparing the results with the properties of the suprarenal aorta and the anterior wall of the aneurysm. METHODS: Sixteen infrarenal abdominal aortic aneurysms found in necropsies were removed and dissected in laboratory. The original anatomy of the aneurysms was restored with the aid of a compliant balloon inserted in the specimens lumen and aneurysms with a neck shorter than 10 mm were excluded. Similar transverse fragments from the anterior aneurysm wall, aneurysm neck, and suprarenal aorta were obtained with the aid of a cutting device. Uniaxial destructive tensile tests were performed to obtain the following biomechanical properties: tension, stress, strain energy and strain at the moment of fragment failure, and the thickness of the fragments. Histological analysis was performed with the quantification of collagen and elastin, and middle layer thickness in these three fragments. RESULTS: In twelve ruptured and four unruptured aneurysms, the biomechanical analysis of the fragments showed no statiscally signicant differences between the mean values of the biomechanical properties (tension, stress, strain energy and strain), as well as the thickness of the fragments in the three groups. The percentage of collagen in the neck was significantly lower than in the aneurysm wall (p = 0,010) and was not significantly different from the suprarenal aorta (p = 0,155). Higher percentage of elastin was present in the neck (p < 0,001) and in the suprarenal aorta (p < 0,001) when compared to aneurysms. There was no difference in the quantification of elastin between the neck and the suprarenal segment (p = 0,457). The middle layer thickness showed no significant statistical difference between the three evaluated regions (p = 0,660). CONCLUSIONS: Biomechanical results suggest that the infrarenal aortic aneurysm, rather than a localized process, is a result of diffuse aortic involvement. Both the resistance and elasticity of the aneurysmal segment have similarities when compared to non-dilated aortic segments. In the histological analysis, there is preservation of elastin in non-dilated aortic segments, while there is a reduction in the aneurysmal wall; and there is greater collagen deposition in the aneurysmatic region
8

Volumetria  e parâmetros biomecânicos detectados pela Ultrassonografia 3D e 2D em aortas abdominais de pacientes com e sem aneurisma / Volumetry and biomechanical parameters detected by 3D and 2D ultrasound in abdominal aortas of patients with and without an aortic aneurysm

Batagini, Nayara Cioffi 10 October 2016 (has links)
INTRODUÇÃO: O diâmetro transverso máximo (DTM) de um aneurisma da aorta abdominal (AAA), a medida mais comumente utilizada para determinar quando uma intervenção cirúrgica está indicada nos portadores desta afecção, tem limitações e não reflete o exato risco de rotura. Parâmetros biomecânicos e morfológicos detectados pelo ultrassom (US) com propriedades tridimensionais (3D), podem ajudar a melhor entender o comportamento dos AAA e a determinar o melhor momento para o tratamento cirúrgico deste grupo de pacientes. OBJETIVOS: Verificar a capacidade e a viabilidade do ultrassom bidimensional (US-2D) acoplado com algoritmos de speckletracking em avaliar as propriedades biomecânicas da aorta em pacientes com e sem AAA. Mensurar o volume parcial dos AAA através do ultrassom tridimensional (US- 3D) e compará-lo com o volume estimado pela tomografia computadorizada (TC). MÉTODOS: Este foi um estudo prospectivo. Trinta e um pacientes com aortas normais (grupo 1), 46 pacientes com AAA de diâmetro máximo entre 3,0 - 5,5 cm (grupo 2) e 31 pacientes com diâmetro dos AAA >- 5,5 cm (grupo 3) foram submetidos ao exame de US 2D/3D da aorta infrarrenal, e as imagens foram pós-processadas antes de serem analisadas. No diâmetro máximo, o strain (deformação) circunferencial global e a rotação global máxima acessados pelo algoritmo de speckle-tracking 2D foram comparados entre os três grupos. O strain regional da parede posterior foi também comparado com o da parede anterior em todos os grupos. Os dados de volumetria obtidos usando o US-3D de 40 pacientes foram comparados com os dados de volumetria obtidos por uma TC contemporânea. RESULTADOS: A mediana do strain circunferencial global foi 2,0% (interquartile range (IR): 1,0 - 3,0), 1,0% (IR: 1,0 - 2,0) e 1,0% (IR: 1,0 - 1,75) nos grupos 1, 2 e 3 respectivamente (p < 0,001). A mediana da rotação global máxima diminuiu progressivamente dos grupos 1 ao 3 (1,38º (IR: 0,77 - 2,13), 0,80º (IR: 0,57 - 1,0) e 0,50º (IR: 0,31 - 0,75) (p < 0,001)). Na análise regiãoespecífica, o pico de strain na parede posterior foi significativamente maior que na parede anterior apenas no grupo 3 (p = 0,003). Os volumes dos AAA estimados pelo US-3D tiveram boa correlação com a TC (R-square = 0,76). CONCLUSÕES: O US é capaz de detectar parâmetros biomecânicos distintos entre aortas normais, aneurismas pequenos e aneurismas grandes. A propriedade 3D do US é capaz de determinar o volume dos AAA e apresenta boa correlação com o método padrão ouro (TC). Estudos prospectivos e com seguimento longo são necessários para aprofundar a compreensão não invasiva do comportamento biomecânico e morfológico dos AAA e correlacionar esses parâmetros com o risco de rotura / INTRODUCTION: The maximum transverse diameter of an abdominal aortic aneurysm (AAA), the most common measurement utilized to determine whether surgical intervention is indicated, has limitations and does not reflect the exact risk of rupture. Biomechanical and morphological parameters detected by ultrasound (US), including three-dimensional (3D) properties, can help to better understand the behavior of AAA and to determine the optimal approach to treatment in this group of patients. OBJECTIVES: To demonstrate the feasibility and the ability of the US with speckletracking algorithms to evaluate biomechanical parameters of the aorta in patients with and without abdominal aortic aneurysm (AAA). To measure the partial aneurysm volume by 3D-US and to compare it with the aneurysm volume measured by computed tomography (CT). METHODS: It was a prospective study. Thirty-one patients with normal aortas (group 1), 46 patients with AAA measuring 3.0 - 5.5 cm (group 2) and 31 patients with AAA >- 5.5 cm (group 3) underwent a 2D/3D US examination of the infrarenal aorta, and the images were post-processed prior to being analyzed. In the maximum diameter, the global circumferential strain and the global maximum rotation assessed by 2D speckle-tracking algorithms were compared among the three groups. The regional strain on posterior wall was also compared to that in the anterior wall for all groups. The volumetry data obtained using 3D-US from forty AAA patients was compared with the volumetry data obtained by a contemporary CT. RESULTS: The median global circumferential strain was 2.0% (interquartile range (IR): 1.0 - 3.0), 1.0% (IR: 1.0 - 2.0) and 1.0% (IR: 1.0 - 1.75) in groups 1, 2 and 3, respectively (p < 0.001). The median global maximum rotation decreased progressively from group 1 to 3 (1.38º (IR: 0.77 - 2.13), 0.80º (IR: 0.57 - 1.0) and 0.50º (IR: 0.31 - 0.75) (p < 0.001)). In the region-specific analysis, the strain in the posterior wall was significantly higher than anterior wall only in group 3 (p = 0.003). AAA volume estimations by 3D-US correlated well with CT (R-square = 0.76). CONCLUSIONS: The US can detect distinct biomechanical parameters between normal aorta, small aneurysms and big aneurysms. The 3D property of US is able to determine AAA volume and correlates well with the gold standard technique (CT). Prospective studies and with long-term follow-up are necessary in order to deepen the non invasive understanding of AAA biomechanical and morphological behavior and to correlate those parameters with rupture risk
9

Management of thoracoabdominal aortic aneurysms and dissections : with emphasis on spinal cord protection in aneurysm repair and non-surgical treatment of type-B dissection /

Winnerkvist, Anders, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2006. / Härtill 6 uppsatser.
10

Análise funcional do endotélio no perioperatório de operações vasculares / Perioperative evaluation of endothelial function in patients undergoing vascular surgery

Daniela Calderaro 09 April 2008 (has links)
Apesar dos grandes avanços na medicina perioperatória, as operações vasculares ainda estão associadas a elevada morbi-mortalidade. A fisiopatologia dos eventos perioperatórios é complexa, envolvendo a instabilização de placas ateroscleróticas, o que não é contemplado nos algoritmos para estratificação de risco cardíaco perioperatório. Acreditamos que a identificação de características relacionadas à instabilização de placas incipientes, como alterações na reatividade vascular e maior atividade inflamatória, pode melhorar a acurácia da estimativa de risco e a análise do comportamento perioperatório destas características pode elucidar importantes mecanismos fisiopatológicos. Estudamos 100 pacientes com indicação de operação vascular e aferimos por meio de ultrassom-Doppler de artéria braquial, a hiperemia reativa (HR), marcador de função microvascular, e a dilatação mediada pelo fluxo (DMF), marcador de função endotelial, antes e após a operação. Analisamos também os níveis de proteina-C reativa ultra-sensível (PCR-us). A operação foi realizada em 96 pacientes e 27 deles apresentaram algum evento até o 30º dia pós-operatório: 4 óbitos cardíacos, 5 infartos agudos do miocárdio, 2 acidentes vasculares cerebrais isquêmicos, 2 elevações isoladas de troponina, 1 embolia de pulmão, 2 reoperações e 11 óbitos não cardíacos. Detectamos disfunção endotelial em 70% dos pacientes, mas não observamos nenhum padrão característico de comportamento perioperatório da DMF, ou associação significativa entre a mesma e os eventos. Observamos significativo aumento da PCR-us após a intervenção cirúrgica (0,5mg/dL x 3,01mg/dL, P=0,001), mas sem associação com eventos. Identificamos forte associação entre disfunção microvascular, representada pela menor velocidade de fluxo na artéria braquial durante a hiperemia reativa, e eventos: 81 cm/s + 20 x 95 cm/s + 28 ( P= 0,02). Concluímos que a identificação de disfunção microvascular no pré-operatório pode estratificar o risco de complicações perioperatórias e que embora não tenhamos observado piora da vasodilatação mediada pelo fluxo, não podemos afastar que haja piora da função endotelial no perioperatório. O aumento de PCR-us denota grande diátese inflamatória, que pode estar relacionada à disfunção endotelial. / Despite great advances in perioperative care, major vascular surgeries are still related to high morbidity and mortality. The pathophysiology of perioperative cardiac events is complex and comprehends atherosclerotic plaque instability, witch is not contemplated in the current algorithms for cardiac risk estimation. We hypothesized that the identification of characteristics related to predisposition for plaque instability, such as abnormalities in the vascular reactivity, is very promising and the characterization of this parameter`s behavior in the perioperative setting contributes to the better understanding of event\'s pathophysiology. We prospectively studied a cohort of 100 patients, candidates for elective major vascular surgery and assessed, by Doppler ultrasound in the brachial artery, reactive hyperemia(RH), a marker of microvascular function, and flow mediated dilation(FMD), a marker of endothelial function, before and after surgery. We also obtained C-reactive protein-high sensitive assay (CRP-hs) before and after surgery. Ninety six patients were submitted to the planned vascular surgery and 27 patients had an event up to the 30º postoperative day. We observed 4 cardiac deaths, 5 acute myocardial infarctions, 2 isolated troponin elevations, 2 ischemic strokes, 1 pulmonary embolism, 2 reoperations and 11 noncardiac deaths. Results: although there was no significant difference in the preoperative FMD between patients with and without events: 4.83% + 6.81 x 5.88% + 6.00 (p= .457), respectively, low RH response, measured as lower peak flow velocity in RH, was associated to events: 81 cm/s + 20 x 95 cm/s + 28 (p=0,02). There was no significant difference in the preoperative CRP-hs between groups (median: 0.51mg/dL (IQR 2.12) x 0.41mg/dL (IQR 0.59), p= .234). There was no significant difference between FMD before and after surgery but we detected an almost 6-fold increase in CRP-hs after surgery: 0.50mg/dL x 3.01mg/dL (p < .001), respectively. Our study demonstrated that microvascular dysfunction is closely related to perioperative events after major vascular surgery and is a better marker of perioperative risk than endothelial dysfunction, in specific conditions.

Page generated in 0.0701 seconds