• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 461
  • 12
  • 12
  • 12
  • 11
  • 9
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 471
  • 155
  • 79
  • 64
  • 48
  • 46
  • 45
  • 44
  • 40
  • 37
  • 32
  • 32
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Análise da frequencia do polimorfismo rs12979860 C/T no gene IL28B em pacientes acometidos por câncer gástrico /

Moura, Kelly Cristina Rodrigues de. January 2015 (has links)
Orientador: Adriana Camargo Ferrasi / Banca: Maria Inês de Campos Moura Pardini / Banca: Juliana Garcia de Oliveira / Resumo: O câncer gástrico é um dos tipos de câncer mais comum e está associado com uma alta frequência de mortalidade. Embora nas últimas décadas tenha ocorrido um decréscimo na incidência mundial, o prognóstico desta patologia permanece ruim, principalmente quando o diagnóstico é feito em estágios avançados. A etiologia é complexa e multifatorial, onde a combinação de fatores genéticos e ambientais parecem estar envolvidos na carcinogênese e progressão da doença. Desta forma, o objetivo deste estudo foi determinar a frequência do polimorfismo rs12979860 C/T no gene IL28B em amostras de carcinoma gástrico provenientes de dois estados brasileiros, São Paulo e Ceará, associando às características clínicas e epidemiológicas desses pacientes. Os resultados demonstraram que 29,7% dos pacientes apresentam o genótipo CC, enquanto a frequência dos indivíduos heterozigotos e (CT) e homozigotos (TT) foram 56,3% e 9%, respectivamente. Em comparação com dados descritos na literatura e do dBSNP de populações usadas como controle, a frequência do alelo T foi mais alta nos pacientes acometidos por câncer gástrico (tumor difuso: 45,5%, tumor intestinal: 39%, literatura: 11 a 35 e dBSNP: 36%). Ainda neste contexto, encontramos uma significante menor frequência do genótipo CC entre os pacientes acometidos por tumores difusos (22,7%), quando comparados aos indivíduos saudáveis (44 a 51%). Nos casos provenientes da população cearense o alelo C foi significativamente mais elevado no tipo intestinal (67%) quando comparado ao tipo difuso (50%), ressaltando a maior frequência do alelo T nos casos difusos. Analisando-se a frequência do polimorfismo rs12979860 C/T e a genotipagem de Helicobacter pylori foi observada uma forte associação entre o genótipo e a infecção pela bactéria CagA+, onde pacientes portadores da cepa mais patogênica (CagA+) apresentaram frequência maior do genótipo menos protetor (TT), principalmente no... / Abstract: Gastric cancer is one of the most common types of cancer and is associated with a high mortality rate. Although in recent decades there has been a decrease in the global incidence, prognosis of this condition remains poor, especially when the diagnosis is made in advanced stages. The etiology is complex and multifactorial, where the combination of genetic and environmental factors appear to be involved in carcinogenesis and progression of the disease. Thus, the aim of this study was to determine the frequency of the polymorphism rs12979860 C / T in the IL28B gene in gastric carcinoma samples from two Brazilian states, São Paulo and Ceará, associating the clinical and epidemiological characteristics of these patients. The results showed that 29.7% of patients present with the CC genotype, while the frequency of heterozygotes and (TC) and homozygous (TT) were 56.3% and 9%, respectively. Compared to data reported in the literature and used as control populations of dbSNP, the frequency of the T allele was higher in patients affected by gastric cancer (diffuse tumor: 45.5%, intestinal tumor: 39%, literature: 11-35 and dbSNP: 36%). Also in this context, we found a significant lower frequency of the CC genotype among patients affected by diffuse tumors (22.7%) when compared to healthy subjects (44-51%). In cases from Ceará population the C allele was significantly higher in the intestinal type (67%) compared to the diffuse type (50%), emphasizing the greater frequency of the T allele in diffuse cases. Analyzing the frequency of polymorphism rs12979860 C / T and genotyping of Helicobacter pylori was observed a strong association between genotype and infection with CagA + bacteria, where patients with the most pathogenic strain (CagA +) had a frequency higher than genotype less protective (TT), particularly in diffuse histotype (p = 0.001). In addition, this same allele was significantly associated with the occurrence of metastases in ... / Mestre
172

Avaliação comparativa das alterações dentoesqueléticas promovidas pelos aparelhos 'Jasper Jumper' e 'Extrabucal com ancoragem cervical', ambos associados à aparelhagem fixa no tratamento da Classe II, divisão 1, de Angle. / Evaluation assessment of dentoskeletal changes produced by the Jasper Jumper appliance and the cervical headgear, both followed by the fixed appliance therapy, for Class II, Division 1 treatment.

Oliveira Junior, Jose Norberto de 25 January 2002 (has links)
Comparou-se cefalometricamente os efeitos dentoesqueléticos promovidos pelo Jasper Jumper e o aparelho extrabucal com ancoragem cervical, ambos associados à aparelhagem fixa, no tratamento da Classe II, divisão 1, de Angle. Para tanto, foram utilizadas 150 telerradiografias em norma lateral de 75 jovens, divididos em três grupos de 25, sendo 13 do gênero masculino e 12 do feminino. Os jovens do grupo 1 não receberam nenhum tipo de tratamento para a Classe II, divisão 1 e apresentaram uma idade média inicial de 11,82 anos e um tempo de observação de 1,95 anos. O grupo 2 utilizou o aparelho Jasper Jumper, com idade média inicial de 11,85 anos e tempo médio de observação de 1,96 anos. O terceiro grupo utilizou o aparelho extrabucal com ancoragem cervical e apresentou uma idade média inicial de 12,29 anos, com tempo de observação de 1,90 anos. A comparação entre as grandezas iniciais evidenciou uma grande similaridade entre os 3 grupos, na fase pré- tratamento, indicando a possibilidade de comparações diretas entre os mesmos. Sendo assim, realizou-se a análise de variância – ANOVA e o teste de Tukey para a comparação intergrupos. Os resultados demonstraram que os distintos aparelhos promoveram efeitos específicos sobre os diversos componentes avaliados. O crescimento anterior da maxila foi restringido significantemente pelo aparelho extrabucal com ancoragem cervical, enquanto, o crescimento mandibular demonstrou um comportamento semelhante entre os três grupos estudados, embora discretamente maior para o grupo que utilizou o aparelho Jasper Jumper. No entanto, a relação maxilomandibular evidenciou uma melhora significante para os dois grupos tratados. A análise do padrão de crescimento craniofacial não revelou alteração significante entre os grupos. O efeito mais significante do componente dentoalveolar superior foi a retrusão dos incisivos superiores pelo aparelho extrabucal com ancoragem cervical. Enquanto, o grupo que utilizou o aparelho Jasper Jumper evidenciou principalmente efeitos sobre o componente dentoalveolar inferior, por meio de uma inclinação vestibular e protrusão dos incisivos inferiores e uma verticalização, mesialização e extrusão dos molares inferiores, em relação ao grupo controle. Deste modo, a correção da má oclusão de Classe II ocorreu, principalmente, devido as alterações do componente dentoalveolar do que as alterações do componente esquelético. / The objective of this cephalometric study was to compare the dentoskeletal effects of the Jasper Jumper appliance and the cervical headgear, both associated with the Edgewise appliance, for the treatment of Class II, Division 1 malocclusion. All measurements were obtained for each patient on two lateral headfilms, at pretreatment and posttreatment. The Jasper Jumper group consisted of 25 patients with initial mean age of 11.85 years and an average treatment time of 1.96 years. The second group, treated with the cervical headgear, consisted of 25 patients with initial mean age of 12.29 years and an average treatment time of 1.90 years. In all patients, Class II molar relationships were successfully corrected to Class I molar relationships. A sample of 50 treated patients was compared to a group of 25 untreated patients, with initial mean age of 11.82 years and an average treatment time of 1.95 years. The results showed that the cervical headgear group demonstrated a restriction in the forward growth of the maxilla, while the mandibular growth is similar of the three groups. The maxilomandibular relationship improved the both group treated. In addition, there were no statistically significant differences in the craniofacial growth direction between the three groups. The cervical headgear group produced a greater retrusion of the upper incisors, when compared to the control. While, the Jasper Jumper appliance provided greater statiscally significant dentoalveolar effects, with a mesial movement of the lower molars. The lower incisors demonstrated both proclination and labial tipping with the Jasper Jumper appliance, when compared to the untreated group. It was concluded that the main effects for Class II treatment were mostly dentoalveolar, with a smaller skeletal effects.
173

Avaliação longitudinal da inclinação axial mesiodistal dos molares superiores decorrente do uso do aparelho Pendulum associado ao aparelho fixo por meio de radiografias panorâmicas / Longitudinal evaluation of axial mesiodistal inclination in maxillary molars as a result of using the Pendulum device associated with fixed appliance, through panoramic radiographs

Rocha, Caroline Andrade 23 February 2011 (has links)
O objetivo deste estudo foi avaliar, por meio das radiografias panorâmicas, o comportamento longitudinal da inclinação axial mesiodistal dos molares superiores decorridos cinco anos após o tratamento realizado com o aparelho Pendulum seguido de aparelhagem ortodôntica fixa e comparar os resultados com os valores médios normais. A amostra consistiu de 20 pacientes (14 do gênero feminino e 6, do masculino) com má oclusão de Classe II tratada por meio da distalização dos molares superiores. A média da idade, ao início do tratamento (T1), foi de 14,27 ± 1,62 anos, ao final do tratamento (T2), 18,59 ± 1,82 anos, e, cinco anos pós-tratamento (T3), 23,77 ± 2,04 anos. A média do tempo de tratamento foi de 4,36 ± 0,79 anos e de avaliação pós-tratamento foi de 5,18 ± 1,14 anos. Como grupo controle, utilizou-se os valores angulares médios normais de molares superiores obtidos por Ursi (1989), sendo que essa obtenção partiu de radiografias panorâmicas de indivíduos com oclusão normal apresentando idades entre 12 e 17 anos. Para a análise estatística, utilizaram-se os traçados das radiografias panorâmicas nas 3 fases (T1, T2 e T3). Os dados obtidos foram analisados estatisticamente pelo teste ANOVA dependente seguido do teste de Tukey. As médias das inclinações axiais mesiodistais nas fases T1, T2 e T3 foram comparadas com os valores médios normais pelo teste t independente. Os resultados apontaram que os primeiros molares superiores, ao término do tratamento ortodôntico, estavam mais inclinados para a distal, porém, cinco anos após, tenderam a verticalizarem-se naturalmente, voltando a ocupar uma posição próxima ao inicial. Quando comparados com os valores normais, somente o primeiro molar superior esquerdo apresentou, no período T2, valor estatisticamente significante diferente do normal. Os valores correspondentes para os segundos molares superiores não apresentaram estatisticamente significantes quando comparados entre si, nem quando comparados com os valores normais. O tratamento com o Pendulum seguido de aparelhagem ortodôntica fixa promove uma inclinação das coroas dos molares para a distal, tendendo esses dentes, entretanto, no longo tempo pós-tratamento, a verticalizarem-se. / The objective of this study was to evaluate, through panoramic radiographs, the longitudinal conduct of mesiodistal inclination in maxillary molars five years after the treatment performed with the Pendulum device followed by fixed appliance and compare the results with normal mean values. The sample consisted of 20 patients (14 female and 6 male) with Class II malocclusion treated with molar distalization. The average age at pretreatment (T1) was 14.27 ± 1.62 years, at posttreatment (T2), 18.59 ± 1.82 years and at the long-term posttreatment (T3) 23.77 ± 2.04 years. The average length of time of the treatment was 4.36 ± 0.79 years and the evaluation of the long-term posttreatment was 5.18 ± 1.14 years. As a control, it was used the normal mean angular values of molar obtained by Ursi (1989), and this achievement came from panoramic radiographs of subjects with normal occlusion ranging in age from 12 to 17 years. Panoramic radiographs were taken for statistic analysis in all 3 stages (T1, T2, T3). The obtained data were statistically analysed through ANOVA Test dependent followed by Tukey test. The mean mesiodistal axial inclinations stages T1, T2, T3 were compared with normal mean values by the independent t test. The results showed that the first molars were more inclined to distal at posttreatment but five years later they tended to upright naturally, occupying the previous position, close to the original. When compared with normal values, only the left first maxillary molar showed in T2 a statistically different value to the normal. The correspondent values for the second maxillary molars did not show to be statistically significant when compared with each other, nor when compared with normal values. The treatment with the Pendulum, together with the orthodontic appliance, fosters an inclination of the molars to the distal, but tends to upright in the long-term posttreatment.
174

Avaliação microbiana de ligaduras elastoméricas estéticas por meio da técnica checkerboard DNA-DNA hybridization: estudo in vivo / Microbial evalution of esthetic elastomeric ligatures through the Checkerboard DNA-DNA Hybridization technique: in vivo study

Morelli, Raquel Fernanda Bachiega 06 December 2016 (has links)
O método de fixação do arco ortodôntico aos bráquetes cerâmicos é principalmente realizado por meio de ligaduras elastoméricas estéticas e têm sido alvo de atenção, pois, apesar da praticidade, acumulam grande quantidade de biofilme que causa degradação de cor, comprometendo permanentemente a estética. O objetivo desta pesquisa foi avaliar, in vivo, a contaminação microbiana da saliva e de 4 diferentes marcas comerciais de ligaduras estéticas: 1- Unistick Pearl American Orthodontics, Sheboygan, WI, USA; 2- Power Sticks Pearl Ortho Technology, Tampa, Flórida, EUA; 3- Ease to tie, Obscure - 3M Unitek, Monrovia, CA, USA; 4 - Ligadura modular marfimMorelli Ortodontia-Brasil, por meio da técnica Checkerboard DNA-DNA Hybridization. Foram selecionados 23 pacientes (entre 11 e 25 anos) de ambos os sexos, em tratamento ortodôntico corretivo. Foi coletado 1 ml de saliva não estimulada no momento da inserção e trinta dias após a colocação das ligaduras estéticas. Decorridos 30 dias da colocação, as ligaduras elastoméricas foram removidas, processadas individualmente e estocadas a -20°C, até o momento da análise microbiológica. Os dados foram analisados utilizando o software SAS software for Windows versão 9.1.3. Na saliva, não foram encontradas alterações estatisticamente significantes, exceto para o grupo de bactérias do complexo laranja (p=0,0493). Os resultados encontrados nas ligaduras elastoméricas estéticas mostraram acúmulo significativo nas bactérias do complexo laranja (p=0,0167), enquanto que nos outros complexos e nas bactérias cariogênicas não observamos diferenças estatisticamente relevantes. Evidenciou-se que a ligadura estética da marca comercial Morelli, apresentou menores níveis de contaminação bacteriana (p=0,0108) nos meninos. Assim, conclui-se que as ligaduras elastoméricas estéticas, no período de 30 dias, foram multicolonizadas por várias espécies de micro-organismos, especialmente as do complexo laranja, reforçando a necessidade de uma higiene bucal rigorosa em pacientes ortodônticos. / The attachment for orthodontic archwires to ceramic brackets are mainly done by means of aesthetic elastomeric ligatures, therefore, they have been subject of attention because they accumulate a great amount of biofilm, causing color degradation then compromising their aesthetic visual. The objective of this research was to analyze, in vivo, the microbial contamination of saliva and 4 different brands of aesthetic ligatures: 1- Unistick Pearl - American Orthodontics, Sheboygan, WI, USA; 2- Power Sticks -Pearl Ortho Technology, Tampa, Florida, EUA; 3- Ease to tie, Obscure - 3M Unitek, Monrovia, CA, USA; 4 - Ligadura modular marfimMorelli Ortodontia-Brasil, through the Checkerboard DNA-DNA Hybridization technique. Twenty-three patients (between 11 and 25 years old) of both genders, under orthodontic treatment were selected. One milliliter of non-stimulated saliva, at time of inserting the ligatures and 30 days after its insertion, was collected. Thirty days after the placement the elastomeric ligatures were removed, individually processed and stored at -20°C, until the microbiological analysis. The data were analyzed using the SAS software for Windows version 9.1.3. No statistically significant changes were found in the saliva values, except for the bacterias of the orange complex (p = 0.0493). The obtained results in the aesthetic elastomeric ligatures showed a significant increase in the orange bacterial complex (p=0,0057), while in the others complexes no statistically differences were observed. The Morelli commercial brand of aesthetic ligature showed lower bacterial contamination levels (p=0,0108) in boys. Thus, it can be concluded that the aesthetic elastomeric ligatures, in a 30-day period, were multi-colonized by various species of microorganisms, especially from the orange complexes, reinforcing the need for a thorough oral health care in orthodontic patients.
175

Estudo comparativo das alterações do tratamento da má oclusão de classe II com os aparelhos propulsores Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho fixo / Comparative study of changes in the treatment of Class II malocclusion devices with propellants Jasper jumper and Twin Force Bite Corrector, associated with fixed appliance

Fontes, Fernanda Pinelli Henriques 09 May 2016 (has links)
O objetivo desta pesquisa foi comparar as alterações cefalométricas de pacientes com má oclusão de Classe II divisão 1, tratados com os aparelhos Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho ortodôntico fixo. A amostra foi composta por 120 telerradiografias em norma lateral de 60 pacientes, os quais foram divididos em 3 grupos: Grupo Experimental 1, constituído por 20 pacientes com idade inicial média de 12,39 anos, tratados por meio do aparelho Jasper Jumper associado ao aparelho fixo, por um período médio de 2,42 anos; Grupo Experimental 2, contendo 20 pacientes com idade inicial média de 11,83 anos, tratados com o aparelho Twin Force associado ao aparelho fixo, com tempo médio de tratamento de 2,59 anos; Grupo Controle, composto por 20 jovens, com idade inicial média de 12,13 anos e observados por um período médio de 2,21 anos. As alterações foram comparadas entre os grupos, por meio da Análise de Variância e do teste de Tukey. Observou-se que ambos os tratamentos apresentaram um efeito restritivo na maxila, houve melhora significante da relação maxilomandibular nos dois protocolos de tratamento avaliados e promoveram rotação horária do plano oclusal. O grupo Jasper Jumper, promoveu uma significante limitação do desenvolvimento vertical dos molares superiores em relação aos outros grupos. Os incisivos inferiores exibiram maior protrusão e uma extrusão dos molares inferiores nos grupos 1 e 2. Ambos os aparelhos melhoraram significantemente a relação maxilomandibular, os trespasses horizontal, vertical e a relação molar. Os protocolos de tratamento promoveram retrusão dos lábios superiores. / The aim of this study was to compare the cephalometric changes in patients with Class II Division 1 malocclusion, treated with the Jasper Jumper and Twin Force Bite Corrector, associated with fixed orthodontic appliances. The sample consisted of 120 lateral cephalometric radiographs of 60 patients, divided into 3 groups: Experimental Group 1 comprised 20 patients with initial mean age of 12.39 years, treated with the Jasper Jumper appliance associated with device fixed for an average period of 2.42 years; Experimental group 2 with 20 patients with initial mean age of 11.83 years, treated with Twin Force unit associated with braces, with an average treatment time of 2.59 years; Control Group, composed of 20 individuals, average initial age of 12.13 years and observed for an average period of 2.21 years. The changes were compared between groups by ANOVA followed by Tukey test. It was observed that both treatments presented a restrictive effect on the maxilla; there was significant improvement in the maxillomandibular relationship in the two treatment protocols groups evaluated and clockwise rotation of the occlusal plane. The Jasper Jumper group, provided a significant limitation of the vertical development of the maxillary molars in relation to other groups. The lower incisors showed greater protrusion and extrusion of mandibular molars in groups 1 and 2. Both appliances provided significant improvement of maxillomandibular relationship, overjet, overbite and molar relationship. Groups 1 and 2 presented retrusion of the upper lip.
176

Eficiência do aparelho intraoral no tratamento da síndrome da apneia obstrutiva do sono em obesos grau III / Efficiency of intraoral appliance in the treatment of obstructive sleep apnea syndrome in grade III obeses

Alvarenga, Sílvia de Carvalho 27 July 2018 (has links)
Os aparelhos intraorais (AIOs) de avanço mandibular, têm sido sugeridos como tratamentos alternativos aos intolerantes ou não aderentes à pressão positiva contínua nas vias aéreas (CPAP), no entanto não há estudos que avaliem a efetividade de AIO em pacientes obesos grau III, população bastante afetada pela presença de SAOS. Por isso este ensaio clínico randomizado teve por objetivo avaliar a melhora na qualidade de sono, qualidade de vida, sonolência diurna e gravidade de SAOS, antes e após o uso de AIO, comparado com o uso da placa ajustável de silicone, em pacientes com grau III de obesidade. A amostra foi composta por quarente e cinco pacientes com AOS leve/moderada/severa, foram aleatoriamente divididos em dois grupos paralelos: AIO e controle passivo (placa ajustável de silicone). Foram aplicados questionários relativos à qualidade de vida, presença de sonolência diurna excessiva e qualidade do sono e também foram submetidos a exames de polissonografia antes do início e depois de 45 dias de uso do tratamento. Não houve diferença significativa nas variáveis idade e medidas antropométricas entre grupos (p<0,001). Diferenças foram encontradas na qualidade de vida, sonolência diurna e qualidade do sono, em favor do tratamento com AIO (p<0,001) e houve melhora significativa no índice de apneia-hipopneia (IAH) entre o baseline e pós-tratamento no grupo AIO (p<0,001). Pode-se concluir que o AIO proposto foi eficiente e pode ser considerado tratamento alternativo ou coadjuvante viável da SAOS em pacientes obesos grau III. / Intraoral appliances (AIOs) of mandibular advancement have been suggested as alternative treatments to those intolerant or non-adherent to continuous positive airway pressure (CPAP); however, there are no studies evaluating the effectiveness of AIO in grade III obese patients, population affected by the presence of OSAS. Therefore, this randomized clinical trial aimed to evaluate the improvement in sleep quality, quality of life, daytime sleepiness and OSAS severity, before and after the use of AIO, compared to the use of adjustable silicone plaques in patients with grade III of obesity. The sample consisted of forty-five patients with mild / moderate / severe OSA, were randomly divided into two parallel groups: AIO and passive control (adjustable silicone plaque). Questionnaires related to quality of life, excessive daytime sleepiness and sleep quality were applied and polysomnography examinations were also performed before and after 45 days of treatment. There was no significant difference in the variables age and anthropometric measurements between groups (p <0.001). Differences were found in quality of life, daytime drowsiness and sleep quality in favor of AIO treatment (p <0.001) and there was a significant improvement in apnea-hypopnea index (AHI) between the baseline and post-treatment in the AIO group (p <0.001). It can be concluded that the proposed AIO was efficient and could be considered a viable alternative or adjuvant treatment of OSAS in grade III obese patients.
177

Avaliação comparativa das alterações dentoesqueléticas promovidas pelos aparelhos 'Jasper Jumper' e 'Extrabucal com ancoragem cervical', ambos associados à aparelhagem fixa no tratamento da Classe II, divisão 1, de Angle. / Evaluation assessment of dentoskeletal changes produced by the Jasper Jumper appliance and the cervical headgear, both followed by the fixed appliance therapy, for Class II, Division 1 treatment.

Jose Norberto de Oliveira Junior 25 January 2002 (has links)
Comparou-se cefalometricamente os efeitos dentoesqueléticos promovidos pelo Jasper Jumper e o aparelho extrabucal com ancoragem cervical, ambos associados à aparelhagem fixa, no tratamento da Classe II, divisão 1, de Angle. Para tanto, foram utilizadas 150 telerradiografias em norma lateral de 75 jovens, divididos em três grupos de 25, sendo 13 do gênero masculino e 12 do feminino. Os jovens do grupo 1 não receberam nenhum tipo de tratamento para a Classe II, divisão 1 e apresentaram uma idade média inicial de 11,82 anos e um tempo de observação de 1,95 anos. O grupo 2 utilizou o aparelho Jasper Jumper, com idade média inicial de 11,85 anos e tempo médio de observação de 1,96 anos. O terceiro grupo utilizou o aparelho extrabucal com ancoragem cervical e apresentou uma idade média inicial de 12,29 anos, com tempo de observação de 1,90 anos. A comparação entre as grandezas iniciais evidenciou uma grande similaridade entre os 3 grupos, na fase pré- tratamento, indicando a possibilidade de comparações diretas entre os mesmos. Sendo assim, realizou-se a análise de variância – ANOVA e o teste de Tukey para a comparação intergrupos. Os resultados demonstraram que os distintos aparelhos promoveram efeitos específicos sobre os diversos componentes avaliados. O crescimento anterior da maxila foi restringido significantemente pelo aparelho extrabucal com ancoragem cervical, enquanto, o crescimento mandibular demonstrou um comportamento semelhante entre os três grupos estudados, embora discretamente maior para o grupo que utilizou o aparelho Jasper Jumper. No entanto, a relação maxilomandibular evidenciou uma melhora significante para os dois grupos tratados. A análise do padrão de crescimento craniofacial não revelou alteração significante entre os grupos. O efeito mais significante do componente dentoalveolar superior foi a retrusão dos incisivos superiores pelo aparelho extrabucal com ancoragem cervical. Enquanto, o grupo que utilizou o aparelho Jasper Jumper evidenciou principalmente efeitos sobre o componente dentoalveolar inferior, por meio de uma inclinação vestibular e protrusão dos incisivos inferiores e uma verticalização, mesialização e extrusão dos molares inferiores, em relação ao grupo controle. Deste modo, a correção da má oclusão de Classe II ocorreu, principalmente, devido as alterações do componente dentoalveolar do que as alterações do componente esquelético. / The objective of this cephalometric study was to compare the dentoskeletal effects of the Jasper Jumper appliance and the cervical headgear, both associated with the Edgewise appliance, for the treatment of Class II, Division 1 malocclusion. All measurements were obtained for each patient on two lateral headfilms, at pretreatment and posttreatment. The Jasper Jumper group consisted of 25 patients with initial mean age of 11.85 years and an average treatment time of 1.96 years. The second group, treated with the cervical headgear, consisted of 25 patients with initial mean age of 12.29 years and an average treatment time of 1.90 years. In all patients, Class II molar relationships were successfully corrected to Class I molar relationships. A sample of 50 treated patients was compared to a group of 25 untreated patients, with initial mean age of 11.82 years and an average treatment time of 1.95 years. The results showed that the cervical headgear group demonstrated a restriction in the forward growth of the maxilla, while the mandibular growth is similar of the three groups. The maxilomandibular relationship improved the both group treated. In addition, there were no statistically significant differences in the craniofacial growth direction between the three groups. The cervical headgear group produced a greater retrusion of the upper incisors, when compared to the control. While, the Jasper Jumper appliance provided greater statiscally significant dentoalveolar effects, with a mesial movement of the lower molars. The lower incisors demonstrated both proclination and labial tipping with the Jasper Jumper appliance, when compared to the untreated group. It was concluded that the main effects for Class II treatment were mostly dentoalveolar, with a smaller skeletal effects.
178

Estudo comparativo das alterações do tratamento da má oclusão de classe II com os aparelhos propulsores Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho fixo / Comparative study of changes in the treatment of Class II malocclusion devices with propellants Jasper jumper and Twin Force Bite Corrector, associated with fixed appliance

Fernanda Pinelli Henriques Fontes 09 May 2016 (has links)
O objetivo desta pesquisa foi comparar as alterações cefalométricas de pacientes com má oclusão de Classe II divisão 1, tratados com os aparelhos Jasper Jumper e Twin Force Bite Corrector, associados ao aparelho ortodôntico fixo. A amostra foi composta por 120 telerradiografias em norma lateral de 60 pacientes, os quais foram divididos em 3 grupos: Grupo Experimental 1, constituído por 20 pacientes com idade inicial média de 12,39 anos, tratados por meio do aparelho Jasper Jumper associado ao aparelho fixo, por um período médio de 2,42 anos; Grupo Experimental 2, contendo 20 pacientes com idade inicial média de 11,83 anos, tratados com o aparelho Twin Force associado ao aparelho fixo, com tempo médio de tratamento de 2,59 anos; Grupo Controle, composto por 20 jovens, com idade inicial média de 12,13 anos e observados por um período médio de 2,21 anos. As alterações foram comparadas entre os grupos, por meio da Análise de Variância e do teste de Tukey. Observou-se que ambos os tratamentos apresentaram um efeito restritivo na maxila, houve melhora significante da relação maxilomandibular nos dois protocolos de tratamento avaliados e promoveram rotação horária do plano oclusal. O grupo Jasper Jumper, promoveu uma significante limitação do desenvolvimento vertical dos molares superiores em relação aos outros grupos. Os incisivos inferiores exibiram maior protrusão e uma extrusão dos molares inferiores nos grupos 1 e 2. Ambos os aparelhos melhoraram significantemente a relação maxilomandibular, os trespasses horizontal, vertical e a relação molar. Os protocolos de tratamento promoveram retrusão dos lábios superiores. / The aim of this study was to compare the cephalometric changes in patients with Class II Division 1 malocclusion, treated with the Jasper Jumper and Twin Force Bite Corrector, associated with fixed orthodontic appliances. The sample consisted of 120 lateral cephalometric radiographs of 60 patients, divided into 3 groups: Experimental Group 1 comprised 20 patients with initial mean age of 12.39 years, treated with the Jasper Jumper appliance associated with device fixed for an average period of 2.42 years; Experimental group 2 with 20 patients with initial mean age of 11.83 years, treated with Twin Force unit associated with braces, with an average treatment time of 2.59 years; Control Group, composed of 20 individuals, average initial age of 12.13 years and observed for an average period of 2.21 years. The changes were compared between groups by ANOVA followed by Tukey test. It was observed that both treatments presented a restrictive effect on the maxilla; there was significant improvement in the maxillomandibular relationship in the two treatment protocols groups evaluated and clockwise rotation of the occlusal plane. The Jasper Jumper group, provided a significant limitation of the vertical development of the maxillary molars in relation to other groups. The lower incisors showed greater protrusion and extrusion of mandibular molars in groups 1 and 2. Both appliances provided significant improvement of maxillomandibular relationship, overjet, overbite and molar relationship. Groups 1 and 2 presented retrusion of the upper lip.
179

Eficiência do aparelho intraoral no tratamento da síndrome da apneia obstrutiva do sono em obesos grau III / Efficiency of intraoral appliance in the treatment of obstructive sleep apnea syndrome in grade III obeses

Sílvia de Carvalho Alvarenga 27 July 2018 (has links)
Os aparelhos intraorais (AIOs) de avanço mandibular, têm sido sugeridos como tratamentos alternativos aos intolerantes ou não aderentes à pressão positiva contínua nas vias aéreas (CPAP), no entanto não há estudos que avaliem a efetividade de AIO em pacientes obesos grau III, população bastante afetada pela presença de SAOS. Por isso este ensaio clínico randomizado teve por objetivo avaliar a melhora na qualidade de sono, qualidade de vida, sonolência diurna e gravidade de SAOS, antes e após o uso de AIO, comparado com o uso da placa ajustável de silicone, em pacientes com grau III de obesidade. A amostra foi composta por quarente e cinco pacientes com AOS leve/moderada/severa, foram aleatoriamente divididos em dois grupos paralelos: AIO e controle passivo (placa ajustável de silicone). Foram aplicados questionários relativos à qualidade de vida, presença de sonolência diurna excessiva e qualidade do sono e também foram submetidos a exames de polissonografia antes do início e depois de 45 dias de uso do tratamento. Não houve diferença significativa nas variáveis idade e medidas antropométricas entre grupos (p<0,001). Diferenças foram encontradas na qualidade de vida, sonolência diurna e qualidade do sono, em favor do tratamento com AIO (p<0,001) e houve melhora significativa no índice de apneia-hipopneia (IAH) entre o baseline e pós-tratamento no grupo AIO (p<0,001). Pode-se concluir que o AIO proposto foi eficiente e pode ser considerado tratamento alternativo ou coadjuvante viável da SAOS em pacientes obesos grau III. / Intraoral appliances (AIOs) of mandibular advancement have been suggested as alternative treatments to those intolerant or non-adherent to continuous positive airway pressure (CPAP); however, there are no studies evaluating the effectiveness of AIO in grade III obese patients, population affected by the presence of OSAS. Therefore, this randomized clinical trial aimed to evaluate the improvement in sleep quality, quality of life, daytime sleepiness and OSAS severity, before and after the use of AIO, compared to the use of adjustable silicone plaques in patients with grade III of obesity. The sample consisted of forty-five patients with mild / moderate / severe OSA, were randomly divided into two parallel groups: AIO and passive control (adjustable silicone plaque). Questionnaires related to quality of life, excessive daytime sleepiness and sleep quality were applied and polysomnography examinations were also performed before and after 45 days of treatment. There was no significant difference in the variables age and anthropometric measurements between groups (p <0.001). Differences were found in quality of life, daytime drowsiness and sleep quality in favor of AIO treatment (p <0.001) and there was a significant improvement in apnea-hypopnea index (AHI) between the baseline and post-treatment in the AIO group (p <0.001). It can be concluded that the proposed AIO was efficient and could be considered a viable alternative or adjuvant treatment of OSAS in grade III obese patients.
180

Comportamento das curvas resultantes da interação das leituras visuais e digitais na triagem de auto-anticorpos (FAN) pela imunofluorescência indireta

Francescantonio, Paulo Luiz Carvalho 12 May 2005 (has links)
Made available in DSpace on 2016-08-10T10:55:53Z (GMT). No. of bitstreams: 1 PAULO LUIZ CARVALHO FRANCESCANTONIO.pdf: 1917098 bytes, checksum: 4ed2ad7744c8c5690f722bdbc60c57b7 (MD5) Previous issue date: 2005-05-12 / The indirect immunofluorescence test is widely used in the clinical pathology laboratory. Among the tests in this group we have FAN, which means research of antibodies against components of the nucleus, nucleolus, cytoplasm and mitotic spindle. This test, used in the selection of auto antibodies, imposes some difficulties for its application such as: it requires two highly specialized technicians to read of the slides, what prevents automation of the process; low standardization; lack of documentation; decay of the fluorescence while reading of the slide; lack of standardization of the optic system; great variability of substrata and the dependence on the experience of the observer. These factors limit the use of the test to a small group of laboratories worldwide. This work aims at minimizing those difficulties by creating the basic knowledge on the behavior of the resultant curves of the interactions between visual and digital readings. The images visual read are digitally captured and the intensity of its fluorescent green is evaluated. We analyze the curves produced for five patterns of FAN: homogeneous nuclear pattern, speckled centromeric nuclear pattern, mixed fine speckled nuclear standard and mitotic spindle NuMa 1, mitotic spindle pattern NuMa 2 and nucleolar homogeneous pattern. The behavior of the resultant curves of the interaction of digital and visual readings shows that the digital readings within a single title in the same patterns can be differentiated in 96,7% of the cases. In a second within patterns analysis, homologous dilutions, with several titles in the same pattern were distinguished in 99,2% of cases. The inter patterns analysis, which assesses whether the calibration curve obtained using homogeneous nucleolar pattern can be used for the others patterns, we obtained 98,8% of concordance. The creation of a new technology through knowledge of the behaviors of the resultant curves of the visual and digital readings of FAN testes can cause what we call &#8220;technological unemployment&#8221;, this phenomenon can be aggravated if society is in a decreasing economic cycle. In Brazil there is a group of public policies theat guide the application of a fund to support worker qualification minimizing the impact caused by the introduction of a new technology. / O teste de imunofluorescência indireta é amplamente utilizado no laboratório de patologia clinica. Entre os ensaios efetuados, temos o FAN, que significa pesquisa de anticorpos contra componentes do núcleo, nucléolo, citoplasma e aparelho mitótico. Este ensaio, utilizado na triagem de auto anticorpos, apresenta algumas dificuldades para sua realização tais como: dois técnicos altamente especializados para a leitura das lâminas, o que impossibilita automação; baixo nível de padronização; pouca documentação queda da fluorescência durante a leitura da lâmina; falta de padronização do sistema óptico, a grande variabilidade dos substratos e a dependência da experiência do observador. Isto limita o uso do ensaio a um grupo menor de laboratórios em todo mundo. Este trabalho visa minimizar essas dificuldades criando o conhecimento básico do comportamento das curvas resultantes das interações de leituras visuais e digitais. As imagens lidas visualmente são capturadas digitalmente e têm a intensidade de seu verde fluorescente avaliadas. Analisamos as curvas produzidas por cinco padrões de FAN: padrão nuclear homogêneo, padrão nuclear pontilhado centromérico, padrão misto nuclear pontilhado fino e aparelho mitótico NuMa 1, padrão aparelho mitótico tipo fuso mitótico NuMa 2 e padrão nucleolar homogêneo. O comportamento das curvas resultantes da interação das leituras digitais e visuais mostra que os valores digitais das diluições dentro de um mesmo título em um mesmo padrão, podem ser diferenciados em 96,7% dos casos. Na segunda análise intrapadrão, as diluições homólogas, entre os diversos títulos dentro de um mesmo padrão, têm seus valores digitais diferenciados em 99,2% dos casos. A análise interpadrões, que avalia se a curva de calibração produzida utilizando o padrão nuclear homogêneo pode ser utilizada nos demais padrões, demonstrou um nível de concordância de 98,8% nos ensaios examinados. A criação de uma nova tecnologia derivada do conhecimento do comportamento das curvas resultantes das leituras visuais e digitais podem gerar o que denominamos desemprego tecnológico, essa situação pode ser agravada se a sociedade se encontra em um ciclo econômico decrescente. No Brasil existe um grupo de políticas publicas que orientam a aplicação do Fundo de amparo ao trabalhador na qualificação de sua mão de obra minimizando o impacto causado pela introdução de uma nova tecnologia.

Page generated in 0.0375 seconds