• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Qualidade das águas de chuva em João Pessoa PB: estudo comparativo com padrões de qualidade para uso residencial

Santana, Natalia Cibely Bezerra 18 June 2012 (has links)
Made available in DSpace on 2015-05-14T12:09:08Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2017808 bytes, checksum: 0161ab3eebb6d1e4c9df67e2aa888379 (MD5) Previous issue date: 2012-06-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The ever so accelerated population growth in several countries coupled to water resources scarcity have become a crucial problem worldwide. According to the UN, the demand for water is twice as much as that of population growth; so many countries will suffer serious problems of water availability, which will certainly be a challenge for most governments to ensure sufficient supply of drinking water for the population. Among the alternative sources of water supply, one of the most promising is that derived from rainwater collecting; where drinking water is replaced by water which is both less expensive and far more accessible, preserving, therefore, its use where drinkability would not be needed. The purpose of the present research is to analyze the quality of rainwater in the city of João Pessoa and to compare it with several quality standards according to its usages in a residence. Samples were collected at 5 points of the system, namely: direct collection from the atmosphere following water precipitation over roofs; from the first millimeters of precipitation collected from water discarded devices; and from two storage reservoirs. Results revealed that rainwater quality both in its raw state and before its contact with the capturing surface is good; therefore, compatible with the standards established by the NBR's No.15.527/07 and No.13.969/97 (classes 1, 2 and 3), by ANA/05 (class1), and by CONAMA Resolution No.357/05 (class1 of freshwater). Upon flowing over the roof, water quality is deteriorated due to the accumulation of impurities, especially after a dry season. However, it was found that by giving rainwater a simplified treatment, such as simple filtration, or by discarding water from first rains, its quality may be restored up to a satisfactory level, making it compatible to non-potable use, such as in toilet discharge, general cleaning and garden watering. By examining the Ministry of Health Decree No. 2.914/2011, one could verify that the non-conformity alone with the established standards for total and fecal coliforms may render water useless for potable purposes. / O acelerado crescimento populacional em diversos países e a escassez dos recursos hídricos têm se tornado uma preocupação crescente em todo o mundo. De acordo com a ONU, a demanda de água cresce com velocidade duas vezes maior que o crescimento da população, desta forma haverá sérios problemas de disponibilidade hídrica em muitos países e que será um desafio para os governos assegurar um adequado abastecimento de água potável a toda população. Dentre as fontes alternativas para o abastecimento de água uma das mais promissoras é a captação de águas pluviais para aproveitamento, onde a água potável é substituída por uma água menos cara e mais acessível, preservando assim o seu uso onde não seria necessária a potabilidade. Assim, o objetivo desta pesquisa é de analisar a qualidade da água de chuva na cidade de João Pessoa, para fins de comparação com diversos padrões de qualidade conforme os usos da água em residências. No sistema de captação montado para o estudo foram coletadas amostras em 5 pontos do sistema, quais sejam: coleta direta da atmosfera, após escoamento sobre o telhado, nos dispositivos de descarte dos primeiros milímetros de precipitação, e em 2 reservatórios de acumulação. Os resultados mostraram que a qualidade da água pluvial em seu estado bruto e antes de entrar em contato com a superfície de captação é boa, compatível com os padrões estabelecidos pelas NBR s Nº 15.527/07 e Nº 13.969/97 (classes 1, 2 e 3), pela ANA/05 (classe 1) e pela Resolução CONAMA Nº 357/05 (classe 1 de água doce). Ao escoar pelo telhado a qualidade da água se deteriora devido ao acúmulo de impurezas, principalmente após um período de estiagem. Entretanto, verificou-se que promovendo tratamento simplificado à água de chuva, como a filtração simples ou o descarte das primeiras chuvas, a qualidade dela volta a ser satisfatória, podendo ser aproveitada para fins não potáveis, tais como descarga de vasos sanitários, lavagem de pisos e veículos, irrigação de jardins. Em relação à Portaria do Ministério da Saúde Nº 2.914/11, verificou-se o não atendimento apenas aos padrões de potabilidade estabelecidos para os coliformes totais e fecais, não devendo, portanto, a água ser utilizada com finalidades potáveis.
2

Avaliação do desempenho de uma unidade em escala real para tratamento de água pluvial empregando a filtração rápida por meio de filtro de pressão e amido natural de milho como coagulante primário

Murakami, Marcela Ferreira 23 August 2010 (has links)
Made available in DSpace on 2016-06-02T20:00:36Z (GMT). No. of bitstreams: 1 3409.pdf: 2199737 bytes, checksum: 5aff5a67e09c1c1d2a25bf26142c6ea9 (MD5) Previous issue date: 2010-08-23 / Financiadora de Estudos e Projetos / This study aimed to investigate the performance of an experimental rainwater treatment system for non-potable uses without the first-flush discharge, thus intending to control the quality of captured rainwater and to minimize the rainwater by-pass caused by the first-flush strategy. A full-scale direct filtration unit was operated and a solution of natural corn starch was used as the primary coagulant. The color, turbidity e coliform efficiencies of the unit was analyzed based on filtration loads and the net water production was estimated. The results indicated that the system was able to reduce the discharge of the first rain batch, although it was not fully adequate in terms of removal efficiency, suggesting that more studies are needed. The reduction of volume was equivalent to 1.7 mm in absolute terms (or 85%). The apparent color and turbidity removal was around 30 and 54% average, respectively. Additionally, the rainwater production cost for harvesting was R$ 0,99/m3 (or 90%) cheaper than the drinking water public source. / O presente trabalho objetivou investigar o desempenho de um sistema experimental de tratamento de água pluvial visando uso não potável, prescindindo o descarte da primeira chuva na expectativa de controlar a qualidade da água pluvial captada e minimizar o volume descartado. Para tal, utilizou-se uma estação de captação e tratamento de águas pluviais após passagem por telhado construída em escala real. Foram realizados ensaios de filtração direta com emprego de filtro de pressão e aplicação de solução de amido natural de milho como coagulante primário. Para avaliação do desempenho do sistema, foram analisadas a eficiência na remoção de impurezas ao longo das carreiras de filtração e a produção efetiva do sistema. Os resultados obtidos indicaram que com o emprego do sistema foi possível reduzir o descarte da primeira chuva, embora não tenha adequado plenamente as precipitações estudadas ao padrão de qualidade preconizado pela NBR 15527/07, sugerindo a necessidade da continuidade dos trabalhos. O tratamento investigado possibilitou redução no valor de descarte da primeira chuva equivalente a 1,7 L (ou 85%) por metro quadrado de área de captação. Em termos de residuais de cor aparente e turbidez, as reduções médias obtidas foram de 30 e 54%, respectivamente. Adicionalmente, comparando-se o custo de operação do sistema de tratamento empregado com a tarifa de água tratada cobrada pela concessionária local, obteve-se uma economia equivalente a, aproximadamente, R$ 0,99/m3 (ou 90%). Por fim, foram discutidas alternativas para melhoria do sistema experimental investigado.
3

Análise de risco do aproveitamento da água de chuva para uso não potável em edificações

Bassanesi, Karine 29 August 2014 (has links)
Made available in DSpace on 2016-06-02T20:09:22Z (GMT). No. of bitstreams: 1 6374.pdf: 3492837 bytes, checksum: 8f055db37f9dcba344e72aacee8ecfe5 (MD5) Previous issue date: 2014-08-29 / This master degree contains a literature review on the conservation of water, rainwater utilization, quality and water treatment, legislation and risk analysis. Was verified that rainwater utilization systems vary widely in type and would be important to be able to correlate the precipitated water, uses and models for each situation. And for this work was used the risk analysis focusing the preliminary hazard analysis. A bibliographic review carried out presented some guides and legislation that could complete quality control parameters for non-potable rainwater utilization, and determine the time to review these parameters to control the operation of the system. The study's preliminary analysis was used to study the greatest dangers in the use of rain-related water quality system, critical control points, the user risks, control measures and mitigation measures. For the case study was addressed the same preliminary hazard analysis for knowledge about the contamination of rainwater in relation to the control parameters and on their own knowledge of project development for rainwater utilization. Through the two analyzes a proposal of guidelines was performed for implantation of rainwater utilization system for the case study and there is a possibility of a real fitness for safe use. / O presente trabalho de mestrado contém uma revisão bibliográfica sobre a conservação da água, o aproveitamento pluvial, qualidade e tratamento da água, legislações e análise de risco. Foi constatado que os sistemas de aproveitamento pluvial variam bastante de tipologia e seria importante poder correlacionar a água precipitada com os usos e os modelos para cada situação. Assim, para o presente trabalho foi utilizada a análise de risco com enfoque na análise preliminar de perigos. Com os estudos dos trabalhos apresentados e todos os guias e legislações, foi possível concluir parâmetros de controle da qualidade para o aproveitamento pluvial não potável, e determinar um tempo para análise desses parâmetros para controle do funcionamento do sistema. O estudo da análise preliminar foi utilizado para estudar os maiores perigos dentro do sistema de aproveitamento pluvial relacionado à qualidade de água, os pontos críticos de controle, riscos ao usuário, as medidas de controle e as medidas mitigadoras. Para o estudo de caso, foi abordada a mesma análise preliminar de perigos para o conhecimento sobre a contaminação da água da chuva em relação aos parâmetros de controle e sobre o próprio conhecimento do desenvolvimento do projeto para o aproveitamento pluvial. Por meio das duas análises, foi realizada uma proposta de diretrizes para a implantação do sistema de aproveitamento pluvial para o estudo de caso e existe a possibilidade de uma adequação real para o uso seguro.
4

Esgotamento sanitário a vácuo: descrição e comparações econômicas / Vacum severage technology description and economic evaluation

Resende Filho, Anabi 23 September 2009 (has links)
A escassez de água no planeta já é uma realidade pontual, inclusive já despontando no horizonte, em nosso país, fora do polígono da seca: na região metropolitana de São Paulo, o modelo de adução, a partir de bacias circunvizinhas, está perto de exaurir, pelos custos que esse tipo de solução adotada desde a época do império romano acarreta nas tarifas para o consumidor final. Assim, a busca pelas chamadas soluções racionais têm, cada vez mais, ganhado adeptos e, dentre estas, a que se tem mostrado mais eficiente e mais eficaz é a tecnologia do esgotamento sanitário a vácuo, visto ser a bacia sanitária a responsável por aproximadamente 40% do consumo residencial de água, e por um percentual semelhante também em edifícios comerciais. A partir do estudo de caso no edifício-sede da Secretaria de Orçamento Federal SOF, em Brasília, foi constatada economia de 30% no consumo médio de água, medido em metros cúbicos, depois da implantação do sistema a vácuo - em substituição ao sistema gravitacional, ocorrida em janeiro de 2008 a par de um aumento de apenas 2% no consumo de energia elétrica, medido em kWh, não produzindo ônus, por força do contrato com a concessionária local de eletricidade, do tipo azul. Foram feitas, ainda, comparações com alternativas de abastecimento, quais sejam água de reuso e o aproveitamento de águas pluviais, este mais comum no Brasil embora nitidamente mais recomendável para construções com até dois pavimentos, enquanto aquele, por enquanto, pode ser considerado uma prospecção teórica para as condições de nosso país / The water shortage in the planet is already a punctual reality that is already rising in our country outside the drought polygon (in northeastern part of Brazil). In the metropolitan area of São Paulo the adduction model coming from the neighboring basins is on the brinks of exhaustion, because this kind of solution costs, adopted since the Roman Empire times, brings up to tariffs to the final customer. In this manner, the search for the so called rational solutions has gained more and more followers and among these the one that has shown more efficiency and accuracy is the vacuum sewerage technology, considering that sanitary basin is responsible for almost 40% of the residential water consumption and a similar percentage occurs also in trade buildings. Taking the case study in the headquarter building of Secretaria de Orçamento Federal (SOF), in Brasília, it was verified a 30% economy in the average water consumption, measured in cubic meters, since the vacuum system was established (replacing the gravitational system), on January 2008, informed about only 2% increase in the electricity consumption, measured in kWh, it means that there was no effective increase in the electricity bill, once the local provide company contract, of the blue type, has foretold small oscillations in the supply without deduction on the bill. It was still done some comparative descriptions with others alternatives water supplies, whichever be grey water and rainwater harvesting, this one widely used in Brazil although it is more suggested to up to two floor buildings while the other, for the time being, can be considered as a theoretical prospection in our country
5

Diretrizes para o gerenciamento da água pluvial nas edificações escolares municipais da cidade de Ribeirão Preto. / Guidelines on rainwater management for Ribeirão Preto municipal school buildings.

Hernandes, André Teixeira 31 August 2006 (has links)
Made available in DSpace on 2016-06-02T20:09:05Z (GMT). No. of bitstreams: 1 DissATH.pdf: 18368287 bytes, checksum: b45251643897100029d341df26cf3598 (MD5) Previous issue date: 2006-08-31 / The current projects of rainwater plumbing systems are extremely simple and present only one exclusive concern: to divert the rainfall from the place where it occurs to the drainage public system. In general, it s possible to verify that they do not attend even the word semantic meaning. The no existence of a coordinated set of action aiming at ampler results makes rainwater plumbing system unconcerned with the surrounding area, not composing harmonically with the urban site in particular, and the environment as a general form. Generally, designers expect only rainwater goes toward out of the site, and that is a good result of a good system. Due the lack of attention to the impact that generates and does harm to society, they ignore its potential as instrument of water building conservation. They do not assess correctly its capacity as a source of supply of so expensive and scarce water, according with its necessities, conveniences or limitations that can exist. Therefore, the goal of this study is to propose a new function for the rainwater plumbing system, in special for Ribeirão Preto municipal school buildings, becoming it from a passive to an active system of environment protection. With a proper and molded conception for this new proposal, the system must contemplate the aspects related to the reduction of the impacts caused by the civil construction activities on urban sites, its preservation and providing environment education for people and also, as an worthy water building management tool. / Os atuais projetos dos sistemas prediais de água pluvial são em sua grande maioria, extremamente simples, apresentando uma única e exclusiva preocupação: a transferência da precipitação do local onde ocorre para o sistema público de drenagem, constituído por sarjetas, galerias e por fim, os córregos e rios. Verifica-se que, em geral, não atendem nem ao sentido semântico da palavra sistema. A inexistência de um conjunto coordenado de ações visando um resultado mais amplo faz com que o sistema predial de água pluvial se dissocie de seu entorno, sem se compor harmônicamente com o meio urbano em particular, e o meio natural de uma forma geral. Na concepção atual de seus projetistas, o simples encaminhamento destas águas para fora da edificação é o resultado esperado de um bom sistema. Alheios ao impacto que gera e que penaliza a socidade, passam ao largo de seu potencial como instrumento de conservação de água nas edificações. Ignoram sua capacidade de suprir as mesmas com tão caro e cada vez mais escasso recurso, de acordo com as necessidades, conveniências ou limitações que possam existir. Portanto, o objetivo deste trabalho consiste na proposição de uma nova função para o sistema predial de água pluvial, em especial nas escolas muncipais de Ribeirão Preto, transformando-o de um sistema passivo de captação e drenagem em um sistema ativo de conservação ambiental. Com uma concepção própria e moldada para esta nova proposta, o sistema deve contemplar os aspectos relacionados à redução dos impactos causados pela ocupação do solo no meio urbano, à preservação e educação ambiental e também, à gestão da oferta de água nas edificações.
6

Aproveitamento de água pluvial em edifícios residenciais multifamiliares na cidade de São Carlos. / Rainwater harvesting in a residential tall building in the city of São Carlos.

Campos, Marcus André Siqueira 06 May 2004 (has links)
Made available in DSpace on 2016-06-02T20:09:10Z (GMT). No. of bitstreams: 1 DissMASC.pdf: 3170204 bytes, checksum: 83bd0768232793a648b29a0d4da7f753 (MD5) Previous issue date: 2004-05-06 / Financiadora de Estudos e Projetos / The potable water scarcity afflicts the begging of the 21st Century, being today, one of the main worries of the manhood. This way, it becomes necessary to reduce the per capita consumption. From the actions that promote the racional use of water, the technological ones seems to be , in the most of the cases, the most recomended to reduce the consumption without being necessary radical changes of the users. One of these technologies is the rainwater harvesting. This one erges as an action of good perspectives since it subistitutes the use of potable water in activities where it is not necessary a good quality water, younder, it will reduce the amount of stormwater in the public drainage net, working as a non-structural action of urban drainage. The lack of kwondlege as well a the real advantages that a rainwater system can bring to a builind, is the points to find out about this issue.. At this paper, it seeked to clear this techonolgy up with the study of national and international examples . It also seeked the cistern sizing, getting the best results to technical and economical issues, as well, as procedures to design and to mantain the devices that make part of the system used in this study. Besides that, it studied the changes that would be necessary to build the system, and the possibles changes at the work routine of the construction company. It also studied the financial feasibility of the investiment of this interprisement, checking the real economical advantages that can be get. It is waited that this research contributes to the development of this techonology, contributing to Racional use of water in residential tall buildings. / A escassez de água potável atormenta o início do Século XXI, sendo hoje uma das principais preocupações da humanidade neste século que começa. Dessa forma, surge a necessidade de redução do consumo per capita. Dentre as ações que promovem o uso racional da água, as tecnológicas parecem ser , na maioria dos casos, as mais recomendadas para reduzir o consumo sem que seja necessário mudanças radicais nos hábitos dos usuários. Entre estas, o aproveitamento de água pluvial surge como uma ação de boas perspectivas, pois substitui o uso de água potável onde a qualidade desta não é necessária e, a retirada desta diminuirá a quantidade de volume de água pluvial lançada na rede pública de drenagem, funcionando como uma medida não-estrutural de drenagem urbana. A falta de conhecimento técnico bem como das reais vantagens que um sistema de aproveitamento de água pluvial poderá trazer para uma edificação são as principais incógnitas desse assunto. Neste trabalho buscou-se clarear a tecnologia, com o estudo de diversos casos nacionais e internacionais. Também se buscou realizar o dimensionamento de forma mais correta e econômica, bem como listar procedimentos para elaboração e manutenção de todos os elementos constituintes do sistema utilizado no edifício objeto de estudo. Além disto, verificou-se as possíveis interferências nos processos construtivos, além de alterações das rotinas de trabalho da construtora, além do estudo da viabilidade financeira do empreendimento, verificando as reais vantagens da implantação do sistema neste caso. Espera-se que esse trabalho contribua para o desenvolvimento de uma tecnologia específica para o uso racional de água.
7

Avaliação do aproveitamento de água pluvial em complexos aeroportuários / Evaluation of rainwater use in airport environments

Moreira Neto, Ronan Fernandes 29 April 2011 (has links)
Made available in DSpace on 2015-03-26T13:28:03Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1701770 bytes, checksum: df336a3ba31c20c51b489e214ecd333b (MD5) Previous issue date: 2011-04-29 / Airport environments are great water consumers and use significant amounts of these resources to attend non-potable demands. The need for non-potable water and the presence of large roof areas, as well as the existence of bird control programs and the absence of large trees all make airports potential places for the implementation of processes and technologies for water conservation through rainwater use systems. This study had the objective to assess the potential for rainwater collected from the roofs in the Tancredo Neves International Airport Complex, in Confins, Minas Gerais, to attend its non-potable water demands, and also to propose a treatment which is economically feasible and ease to be replicated. / Ambientes aeroportuários são pontos de consumo significativos de água e utilizam quantidades expressivas desse bem no atendimento a demandas não potáveis. A elevada necessidade de água não potável, em consonância com a presença de grandes áreas de telhados, existência de programas de controle de pássaros e ausência de árvores de grande porte, configuram os aeroportos como ambientes potenciais à implementação de medidas, processos e tecnologias com vistas à conservação da água através de sistemas de aproveitamento de água pluvial. Este estudo pretendeu avaliar o potencial do Aeroporto Internacional Tancredo Neves AITN, Confins, Minas Gerais, na utilização de água pluvial provenientes de telhados para atendimento de demandas não potáveis e a proposição de uma tecnologia de tratamento economicamente viável e de fácil replicação.
8

Esgotamento sanitário a vácuo: descrição e comparações econômicas / Vacum severage technology description and economic evaluation

Anabi Resende Filho 23 September 2009 (has links)
A escassez de água no planeta já é uma realidade pontual, inclusive já despontando no horizonte, em nosso país, fora do polígono da seca: na região metropolitana de São Paulo, o modelo de adução, a partir de bacias circunvizinhas, está perto de exaurir, pelos custos que esse tipo de solução adotada desde a época do império romano acarreta nas tarifas para o consumidor final. Assim, a busca pelas chamadas soluções racionais têm, cada vez mais, ganhado adeptos e, dentre estas, a que se tem mostrado mais eficiente e mais eficaz é a tecnologia do esgotamento sanitário a vácuo, visto ser a bacia sanitária a responsável por aproximadamente 40% do consumo residencial de água, e por um percentual semelhante também em edifícios comerciais. A partir do estudo de caso no edifício-sede da Secretaria de Orçamento Federal SOF, em Brasília, foi constatada economia de 30% no consumo médio de água, medido em metros cúbicos, depois da implantação do sistema a vácuo - em substituição ao sistema gravitacional, ocorrida em janeiro de 2008 a par de um aumento de apenas 2% no consumo de energia elétrica, medido em kWh, não produzindo ônus, por força do contrato com a concessionária local de eletricidade, do tipo azul. Foram feitas, ainda, comparações com alternativas de abastecimento, quais sejam água de reuso e o aproveitamento de águas pluviais, este mais comum no Brasil embora nitidamente mais recomendável para construções com até dois pavimentos, enquanto aquele, por enquanto, pode ser considerado uma prospecção teórica para as condições de nosso país / The water shortage in the planet is already a punctual reality that is already rising in our country outside the drought polygon (in northeastern part of Brazil). In the metropolitan area of São Paulo the adduction model coming from the neighboring basins is on the brinks of exhaustion, because this kind of solution costs, adopted since the Roman Empire times, brings up to tariffs to the final customer. In this manner, the search for the so called rational solutions has gained more and more followers and among these the one that has shown more efficiency and accuracy is the vacuum sewerage technology, considering that sanitary basin is responsible for almost 40% of the residential water consumption and a similar percentage occurs also in trade buildings. Taking the case study in the headquarter building of Secretaria de Orçamento Federal (SOF), in Brasília, it was verified a 30% economy in the average water consumption, measured in cubic meters, since the vacuum system was established (replacing the gravitational system), on January 2008, informed about only 2% increase in the electricity consumption, measured in kWh, it means that there was no effective increase in the electricity bill, once the local provide company contract, of the blue type, has foretold small oscillations in the supply without deduction on the bill. It was still done some comparative descriptions with others alternatives water supplies, whichever be grey water and rainwater harvesting, this one widely used in Brazil although it is more suggested to up to two floor buildings while the other, for the time being, can be considered as a theoretical prospection in our country

Page generated in 0.0581 seconds