• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 131
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 135
  • 135
  • 63
  • 62
  • 42
  • 26
  • 24
  • 23
  • 23
  • 22
  • 21
  • 21
  • 21
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Análise da eficiência energética do sistema de condicionamento de ar com distribuição pelo piso em ambiente de escritório, na cidade de São Paulo, utilizando o modelo computacional Energyplus. / Energy efficiency analysis of underfloor air distribution (ufad) system for office rooms, at São Paulo city, using the ENERGYPLUS software.

Thais Aya Hassan Inatomi 06 May 2008 (has links)
Este trabalho tem por finalidade avaliar o desempenho energético do sistema de condicionamento de ar com distribuição pelo piso (Underfloor Air Distribution System UFAD) em ambientes de escritório, considerando diferentes possibilidades de arquitetura do sistema e seus modos de operação com ciclos economizadores. Por meio de simulação computacional, as avaliações foram realizadas para o clima da cidade de São Paulo ao longo de um ano metereológico típico, mantendo as condições de conforto térmico no ambiente. O programa de simulação selecionado como ferramenta foi o EnergyPlus 2.1.0.023, visto que modelos numéricos nele implementados representam adequadamente o sistema UFAD e os ciclos economizadores. Como referência para o desenvolvimento dos modelos de simulação foi utilizada uma câmara de testes representativa de um ambiente de escritórios. Esta câmara foi desenvolvida por Leite (2003) para avaliação do conforto térmico propiciado pelo sistema UFAD. As curvas de distribuição de temperatura resultantes das simulações foram similares às curvas resultantes das medições executadas por esta autora. As simulações foram realizadas para duas arquiteturas diferentes do circuito de ar (com e sem desvio do ar de retorno) combinados com três diferentes modos de operação relacionados à vazão do ar exterior. A análise dos dados climáticos da cidade de São Paulo demonstra que a tomada de ar exterior pode ser majorada com a utilização de ciclos economizadores, reduzindo o consumo de energia do sistema. Os resultados desta pesquisa indicam uma estreita relação entre arquitetura do sistema, controle dos ciclos economizadores, e dados climáticos, revelando que a combinação entre esses parâmetros pode reduzir em 34,5% o consumo de energia elétrica do sistema UFAD na cidade de São Paulo. / The purpose of this research is to evaluate the energy performance of the Underfloor Air Distribution (UFAD) system at office buildings, considering different air loops design and economizer cycles while keeping thermal comfort for the weather data of São Paulo city, Brazil. Simulations were held using the EnergyPlus software version 2.1.0.023, since its numerical models can well represent UFAD systems and economizer cycles. One chamber representing an office room was used as reference for the simulation models. This chamber was developed by Leite (2003) to evaluate the thermal comfort conditions provided by the UFAD system. The curves of temperature distribution obtained from simulation were similar to those experimentally obtained by Leite (2003). Simulations were performed for two different air loops (with and without return air bypass) combined with three different outside air controls. The São Paulo weather data analysis demonstrates that the outside air flow can be increased with the use of economizer cycles, reducing electric energy consumption of the UFAD system. The results of this research indicate that there is a tight relationship between the system air loop design, economizer cycle control and weather data, which reveals that the combination between these parameters can reduce about 34,5% the electric energy consumption of UFAD system at São Paulo city.
122

Avaliação ambiental do processo produtivo de aparelhos de ar-condicionado utilizando a ferramenta Análise do Ciclo de Vida (ACV)

Freitas, Daisy Amed das Chagas de 22 July 2013 (has links)
Made available in DSpace on 2015-04-22T22:11:01Z (GMT). No. of bitstreams: 1 Daisy Amed das Chagas de Freitas.pdf: 5797839 bytes, checksum: 5037fb54ff3fc2e2be975b2335d845d3 (MD5) Previous issue date: 2013-07-22 / The industry of air conditioning is a major consumer of raw materials and strong generator of waste. The production process and each step in the life cycle of such products cause impacts contributing to environmental degradation. The air conditioning is one of the leading manufactured products in the Industrial Pole of Manaus and the most sold in the local market due to high temperatures, typical of the region. Therefore, this study evaluated the environmental aspects and potential impacts involved in the production process of window air conditioner, using the tool of Life Cycle Assessment (LCA). LCA is a technique for environmental management based on inventory construction that considers the inputs of raw materials and energy, and waste emissions associated with the production process. In this context, a case study has been conducted in the Amazon Electrolux Ltd, manufacturer of air conditioners of the PIM, where the collection of data was made through desk research, interviews and questionnaires, molded based on the focus of the work and the guidelines established by ABNT NBR ISO 14040:2009, for the study of LCA. Secondly, the LCA methodology was applied, using software SimaPro 7.3 Faculty educational version, in order to identify the environmental impacts involved. The results obtained in the environmental assessment of the production process of window air-conditioning found that the electronic components, printed circuit boards and electrical components represent the greatest environmental burden in the production of these devices, due to the diversity of elements and compounds chemicals present in their compositions and the presence of toxic substances that cause harm to human health and the environment. The main potential impacts to which these inputs contribute are the carcinogenic effects, the use of fossil fuels and inorganic respiratory effects. Potential impacts include the categories of harm to human health, to ecosystem quality and to natural resources, the first being the most significant. The diagnosis of this evaluation made possible the construction of a benchmark survey for analysis and understanding of issues relating to the productive sector of air conditioning, contributing to the promotion of improvements in the product development and process, favoring cleaner production directed for sustainability. / A indústria de aparelhos de ar-condicionado é grande consumidora de matérias-primas e forte geradora de resíduos. O processo de produção e cada uma das etapas do ciclo de vida desses produtos acarretam impactos que contribuem para a degradação ambiental. O aparelho de ar-condicionado é um dos principais produtos manufaturados no Polo Industrial de Manaus e um dos mais vendidos no comércio local, devido às altas temperaturas, típicas da região. Diante disso, o presente trabalho avaliou os aspectos ambientais e impactos potenciais envolvidos no processo produtivo de aparelhos de ar-condicionado de janela, utilizando a ferramenta Avaliação do Ciclo de Vida (ACV). A ACV é uma técnica de gestão ambiental fundamentada na construção de inventário que considera as entradas de matérias-primas e energia, e as emissões de resíduos associadas ao processo produtivo. Nesse contexto, foi realizado um estudo de caso na Electrolux da Amazônia Ltda, empresa fabricante de condicionadores de ar do PIM, onde se fez o levantamento dos dados através de pesquisa documental, realização de entrevistas e aplicação de questionários, moldados com base no foco do trabalho e nas diretrizes estabelecidas pela ABNT NBR ISO 14040:2009, para o estudo da ACV. Num segundo momento, foi aplicada a metodologia de ACV, através da utilização do software SimaPro 7.3, versão educacional Faculty, com o objetivo de identificar os impactos ambientais envolvidos. Os resultados obtidos na avaliação ambiental do processo produtivo de aparelhos de ar-condicionado de janela constataram que os componentes eletrônicos, os painéis e circuitos impressos e os componentes elétricos representam a maior carga ambiental na produção desses aparelhos, em função da diversidade de elementos e compostos químicos presentes em suas composições e da presença de substâncias tóxicas que acarretam danos à saúde humana e ao meio ambiente. Os principais impactos potenciais, para os quais esses insumos contribuem, são os efeitos carcinogênicos, a utilização de combustíveis fósseis e os efeitos respiratórios inorgânicos. Os impactos potenciais abrangem as categorias de danos à saúde humana, à qualidade do ecossistema e aos recursos naturais, sendo o primeiro o mais expressivo. O diagnóstico dessa avaliação tornou possível a construção de um referencial de pesquisa para análise e compreensão de questões relativas ao setor produtivo de aparelhos de ar-condicionado, contribuindo para a promoção de melhorias no desenvolvimento do produto e do processo, favorecendo uma produção mais limpa direcionada para a sustentabilidade.
123

Desenvolvimento de um programa computacional para balanceamento de redes de distribuição de ar. / A development of software to balance air distribution net.

Bendezu Hernández, Luis Miguel Teófanes 25 February 2010 (has links)
O balanceamento de uma rede de distribuição de ar consiste em estabelecer as vazões corretas nos elementos terminais conforme previsto no projeto. A revisão bibliográfica apontou que o balanceamento aplicado à distribuição de ar passou a ser considerado no final dos anos de 1960. A aplicação de modelos matemáticos com a simulação do escoamento do ar nos dutos das redes tem início no final dos anos 80. No presente trabalho o objetivo foi estudar metodologia para simulação e balanceamento de redes de distribuição de ar, implementando-a em um programa de computador. Foram estudados diferentes métodos para realizar o balanceamento: método proporcional, método T e o método direto. Foi adotado o direto, em que as vazões são impostas e as diferenças de pressão determinadas para escoamentos em caminhos em paralelo. Mediante o uso de conceitos que fazem analogia entre a fluido-dinâmica e a eletricidade, foi desenvolvido um algoritmo e elaborado um programa de computador. O aplicativo desenvolvido possui 6 etapas principais: caracterização da rede, perda distribuída, perda localizada, perda total, simulação do escoamento e comparação de caminhos. A partir de um estudo de caso, o programa foi testado simulando uma rede de distribuição. Esta mesma rede teve seu balanceamento avaliado por cálculos em planilha eletrônica. Os resultados do estudo de caso com os valores de pressão para todos os trechos da rede, assim como as diferenças de pressão que definem a magnitude do balanceamento foram comparados e estão coincidentes dentro da margem esperada. / The balancing of a net air distribution consists in establishment the correct flowrate in the terminals elements according the design. The bibliographic review show that the balancing applied in air distribution are consider at the 60`s. In the end of the 80\\2019s the mathematics models beginning applied to air flow simulation in ducts. In the present work the objective is studies the methodology to simulation and balancing air distribution nets using software. Different methods are studies to apply in balance: proportional method, T method and direct method. The direct method is adopted, which the flowrate is fixed and the pressure difference is obtained for the parallel paths. Using fluid-dynamics and electrical analogy concepts an algorithm was developed and a software was prepared. The applicatory developed was divided in 6 main stages: net characterization, continuous losses, local losses, total losses, flow simulation and path comparing. Using a case study the software was tested and the distribution net was simulating. This same net was balancing evaluated by a computational spreadsheet. The case study results present the values of pressure for the sections of the net, and the pressure differences to obtained the balancing. This values was consider coincident with the expected.
124

Desenvolvimento de um programa computacional para balanceamento de redes de distribuição de ar. / A development of software to balance air distribution net.

Luis Miguel Teófanes Bendezu Hernández 25 February 2010 (has links)
O balanceamento de uma rede de distribuição de ar consiste em estabelecer as vazões corretas nos elementos terminais conforme previsto no projeto. A revisão bibliográfica apontou que o balanceamento aplicado à distribuição de ar passou a ser considerado no final dos anos de 1960. A aplicação de modelos matemáticos com a simulação do escoamento do ar nos dutos das redes tem início no final dos anos 80. No presente trabalho o objetivo foi estudar metodologia para simulação e balanceamento de redes de distribuição de ar, implementando-a em um programa de computador. Foram estudados diferentes métodos para realizar o balanceamento: método proporcional, método T e o método direto. Foi adotado o direto, em que as vazões são impostas e as diferenças de pressão determinadas para escoamentos em caminhos em paralelo. Mediante o uso de conceitos que fazem analogia entre a fluido-dinâmica e a eletricidade, foi desenvolvido um algoritmo e elaborado um programa de computador. O aplicativo desenvolvido possui 6 etapas principais: caracterização da rede, perda distribuída, perda localizada, perda total, simulação do escoamento e comparação de caminhos. A partir de um estudo de caso, o programa foi testado simulando uma rede de distribuição. Esta mesma rede teve seu balanceamento avaliado por cálculos em planilha eletrônica. Os resultados do estudo de caso com os valores de pressão para todos os trechos da rede, assim como as diferenças de pressão que definem a magnitude do balanceamento foram comparados e estão coincidentes dentro da margem esperada. / The balancing of a net air distribution consists in establishment the correct flowrate in the terminals elements according the design. The bibliographic review show that the balancing applied in air distribution are consider at the 60`s. In the end of the 80\\2019s the mathematics models beginning applied to air flow simulation in ducts. In the present work the objective is studies the methodology to simulation and balancing air distribution nets using software. Different methods are studies to apply in balance: proportional method, T method and direct method. The direct method is adopted, which the flowrate is fixed and the pressure difference is obtained for the parallel paths. Using fluid-dynamics and electrical analogy concepts an algorithm was developed and a software was prepared. The applicatory developed was divided in 6 main stages: net characterization, continuous losses, local losses, total losses, flow simulation and path comparing. Using a case study the software was tested and the distribution net was simulating. This same net was balancing evaluated by a computational spreadsheet. The case study results present the values of pressure for the sections of the net, and the pressure differences to obtained the balancing. This values was consider coincident with the expected.
125

Manutenção baseada em condição aplicada a um sistema de ar condicionado como requisito para sustentabilidade de edifício de escritórios. / Condition based maintenance applied to an air conditioning system as a prerequisite for office building sustainability.

Marcos Maran 01 September 2011 (has links)
O impacto do Homem sobre a Terra, desde a extração intensiva dos recursos da natureza, extinção das espécies, emissões para o ar e água, consumo de energia e água até as mudanças climáticas do planeta, exigem medidas de contenção e preservação do meio ambiente. O futuro da humanidade é questionado e algo deve ser feito. Nesse contexto surge o conceito de desenvolvimento sustentável. Responsável pelo consumo de 40 a 50% da matéria-prima mundial, 12% da água e 40% das emissões de gases de efeito estufa, a indústria da construção possui importante papel na mitigação dos efeitos nocivos para o meio ambiente e capacidade de atingir altos índices de sustentabilidade. Dentro do ciclo de vida de uma edificação, a fase de Operação/Uso provoca grandes consequências ao meio ambiente e oferece grandes oportunidades de redução dos efeitos adversos. Nessa fase as atividades de manutenção predial acabam por ter seu valor reconhecido. As diversas estratégias de manutenção, em especial a manutenção preventiva baseada em condição, colaboram efetivamente para a durabilidade, desempenho e função da edificação e seus sistemas prediais. Procedimentos de manutenção estão associados à baixa qualidade do ar. A manutenção de sistemas de ar condicionado tem especial destaque devido às consequências para a saúde, bem-estar e produtividade dos ocupantes do edifício. / Due to extensive extraction of natures resources, extinction of species, emission of gases into the atmosphere, water and power consumption, to climatic changes of the planet, mankinds impact on earth requires containment and preservation of the environment. The future of humanity is being questioned and something must be done. Responsible for the consumption of 40 to 50% of raw materials worldwide, 12% of water and 40% of emissions of gases into the atmosphere causing the greenhouse effect, the construction industry has an important role in alleviating the adverse impacts on the environment and the ability to achieve high sustainable levels. Within the lifecycle of a building, the phase of operation/use causes significant environmental consequences but also offers opportunities to alleviate adverse effects. In this phase, the value of building maintenance activities has been recognized. The various strategies for maintenance, principally preventive condition- based maintenance should collaborate effectively towards the durability, performance, function and systems of a building. Air-conditioning maintenance procedures are associated with poor air quality. The maintenance of air-conditioning systems has a special significance due to the effects on health, well-being and productivity of the occupants of the building.
126

Modelagem computacional de válvula de expansão eletrônica para sistema de refrigeração e ar condicionado / Computational modeling of electronic expansion valve in a refrigeration system and air conditioning

Ramirez Buitrago, Ana Maria 15 August 2018 (has links)
Orientador: Gilmar Barreto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T23:40:38Z (GMT). No. of bitstreams: 1 RamirezBuitrago_AnaMaria_M.pdf: 759461 bytes, checksum: 2948f7c4d961f0f71c8c3d790e304829 (MD5) Previous issue date: 2010 / Resumo: Neste trabalho apresentamos a modelagem computacional de uma válvula de expansão eletrônica a partir de dados experimentais de entradas e saídas através de modelos no espaço de estado, usando técnicas de subespaços, com objetivo de ter um sistema de refrigeração e ar condicionado eficiente, combinando eletrônica de potência e computação de modo a fornecer uma melhor solução para conservação de energia. A modelagem e a validação são feitas usando uma implementação computacional dos algoritmos de subespaços do espaço de estado. Os resultados apresentados mostram a validade e vantagens da técnica de modelagem realizada / Abstract: This research shows the computational modeling of a electronic expansion valve based on input and output experimental data using Models in State Space and subspace methods. The aim of this work was to obtain an efficient Cooling and Air Conditioning system by the combination of power electronics and computation, as a result, a better solution for energy conservation was obtained. Modeling and validation are made using a computational implementation of subspace methods algorithms in state space. Achieved results show the validity and advantages of the modeling technique implemented / Mestrado / Automação / Mestre em Engenharia Elétrica
127

Sistema híbrido de resfriamento evaporativo e compressão a vapor para condicionamento do ar em veículos

Eric Ferreira dos Santos 30 September 2011 (has links)
Reunir o condicionamento de ar indireto pela compressão a vapor, usando o fluido refrigerante R134a, ao princípio de resfriamento evaporativo direto, foi o tema foco do trabalho. O resfriamento a compressão de vapor tem como resultado, a entrega do ar condicionado sob condições de conforto que podem ser modificados de modo significativo, se for adicionado aos resultados, o condicionamento por resfriamento evaporativo. A observação dos experimentos se baseou nos processos psicrométricos envolvidos, aliando a saturação adiabática do ar no resfriamento evaporativo conjugado ao efeito frigorífico da diferença de entalpias na entrada e saída do evaporador no ciclo convencional de resfriamento. Foi possível avaliar a redução do coeficiente de desempenho e a capacidade de refrigeração aumentando em função do crescimento da rotação do compressor. No ensaio conjugado, resfriamento evaporativo e compressão a vapor instalados em série, observou-se a redução da efetividade do resfriador evaporativo, quando ocorre o aumento da vazão de ar, além do incremento da capacidade de refrigeração em função da associação dos dois sistemas, sem que houvesse aumento significativo da potência consumida. / Assemble the air conditioning by indirect vapor-compression, using refrigerant R134a, the principle of evaporative cooling direct cooling, was the subject focus of the work. The vapor compression cooling results in the delivery of air conditioning under conditions of comfort that can be changed significantly if we add the results, the conditioning by evaporative cooling. The observation of the experiments are bases on psychometric processes involved, combining the adiabatic saturation of air in the evaporative cooling effect of the combined refrigerator of the difference in enthalpy at the inlet and outlet of the evaporator in the conventional cooling cycle. It was possible to evaluate the reduction of the coefficient of performance and cooling capacity increase due to the increase of compressor speed. During the serial aligned pads evaporative cooling and vapor compression test, there was a decrease of the effectiveness evaporative cooler, when the air flow was added, in addition, it was increased the cooling capacity according to the association of the two systems, with no significant increase the power supplied.
128

Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.

Renata Maria Marè 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
129

Projeto, construção e análise de uma bancada para verificação de parâmetros de desempenho de um sistema de ar condicionado veicular / Project, construction, and analysis of a test bench for verifying of parameters of performance of the vehicular air conditioning system

Silva, Ricardo de Oliveira, 1972- 26 August 2018 (has links)
Orientador: Araí Augusta Bernárdez Pécora / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-26T18:01:21Z (GMT). No. of bitstreams: 1 Silva_RicardodeOliveira_M.pdf: 15867764 bytes, checksum: 658914fead0bb9e86c21db30210e6cb9 (MD5) Previous issue date: 2015 / Resumo: As políticas de redução de consumo de combustíveis e de preservação ambiental e em contrapartida os recentes aumentos da frota veicular no Brasil, especialmente dos veículos equipados com sistema de ar condicionado, demandam estudos de gerenciamento térmico de motores a combustão interna visando melhorias no projeto do sistema e a otimização do consumo de combustível. Esta dissertação de mestrado apresenta o projeto, a construção e a validação de uma bancada para simulação do sistema de ar condicionado veicular (ACV). Neste sistema, o compressor do ciclo de resfriamento por compressão de vapor é acionado por um motor de combustão interna instalado em um banco dinamométrico. A simulação de diferentes condições operacionais do sistema de ACV ocorre por meio do controle de três parâmetros: (1) controle da rotação do compressor, que é acionado pelo motor de combustão interna no banco dinamométrico; (2) controle da carga térmica, por meio da variação da temperatura, da vazão e da umidade relativa do ar que atravessa o evaporador; (3) controle da pressão de condensação por meio da variação da vazão de ar que atravessa o condensador. As curvas características do motor de combustão interna (torque, potência e consumo de combustível) em função de sua rotação são comparadas em duas situações com : (i)o compressor do ciclo de resfriamento ligado e (ii) compressor desligado. A análise foi realizada em condições operacionais controladas e simuladas na bancada desenvolvida. Os resultados dos testes permitiram avaliar a influência do funcionamento do ciclo de resfriamento sobre as principais características do motor de combustão interna e sobre a eficiência do sistema de condicionamento de ar. Esta avaliação permitiu o levantamento de dados importantes para a determinação da melhor relação entre o consumo de combustível e o conforto térmico dos passageiros do veículo, contribuindo para o desenvolvimento tecnológico na área / Abstract: The politics of fuel consumption reduction and environmental preservation, in contrast with a recent increment of vehicular fleet in Brazil, especially for vehicles equipped with air conditioning system, requiring studies of thermal management of internal combustion engines, aiming improvements in the project of the system and optimizing the fuel consumption. The present Master¿s dissertation shows the project, the construction and the validation of a test bench in order to simulate a vehicular air conditioning system. Focusing on the necessary power consumption to produce cooling in a vehicular air conditioning system (ACV), such power is consumed by a vapor compression cycle which uses a compressor to compress the refrigerant gas; this compressor is assembled on an internal combustion engine installed on a dynamometer test bench. The simulation occurred in controlled conditions of the engine and of the blown air properties on the heat exchangers (the evaporator and the condenser). Three parameters tend to maintain the test stable: (1) the compressor speed which is driven by engine; (2) the temperature, the mass flow rate and the relative humidity of the intake air which flows through the evaporator; (3) the condensing pressure which is controlled by the variation of the mass flow rate which passes through the condenser. Thus the characteristic curves of the internal combustion engine (torque, power and fuel consumption) are obtained in controlled conditions in function of the engine speed with the compressor on and off. The test allow to assess the influence of the compressor used on the vehicular air conditioning system on the main characteristics of the internal combustion engine and the performance of the vehicular air conditioning system, when it is requested for pre-set test conditions. That kind of analysis has shown important itself determining the best relationship between the fuel consumption and thermal comfort in vehicle passengers and contributing for the technological development for this area / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
130

Conforto térmico e eficiência energética em hotéis econômicos / Thermal comfort and energy efficiency in Budget Hotels

Buoro, Anarrita Bueno 17 March 2008 (has links)
Este trabalho busca avaliar a eficiência energética e o conforto, em ambiente climatizado artificialmente, dos Hotéis Econômicos de redes internacionais em São Paulo. A avaliação levada a cabo concentrou-se nas unidades habitacionais (UH) desses hotéis, principal produto oferecido por eles, possuidoras de sistema de ar condicionado (SAC), apesar das condições climáticas e das características do uso não determinarem essa necessidade. Com base nos levantamentos sobre as características dos Hotéis Econômicos, foi escolhido um hotel de uma rede internacional em São Paulo como estudo de caso. Nele, avaliou-se o desempenho térmico por meio de medições de temperatura e umidade relativa do ar em duas UH, durante cinco dias. As características físicas desse hotel foram utilizadas como modelo-base para as simulações computacionais realizadas no software TAS NG (2005). A partir dos resultados obtidos nas medições, definiram-se os critérios que seriam utilizados nas variações do modelo paramétrico, resultando em um total de sete cenários, com diferentes características como: vidros, cortina interna, taxa de ventilação e período determinado para ventilação. Levando-se em conta as condições climáticas da cidade de São Paulo e as características físicas e ocupacionais dos apartamentos, verificou-se que é possível obter conforto térmico sem o uso de SAC. Nessas condições, utilizou-se como critério de avaliação o modelo adaptativo da Norma ASHRAE 55 (2004). Os dados dos dias mais representativos de verão e inverno forma utilizados na análise dos ganhos de calor. Foi também avaliado, para o período de um ano, o consumo de energia elétrica do SAC, para resfriamento e aquecimento. Os resultados obtidos auxiliaram na proposição de recomendações de projeto para essa tipologia, buscando soluções que aprimoram o aproveitamento das condições naturais favoráveis para a obtenção de conforto térmico, possibilitando a redução do consumo de energia decorrente do SAC nestes ambientes. Para ilustrar algumas recomendações foram feitos estudos preliminares para as UH e para o pavimento tipo, considerando a integração do SAC com soluções de projeto de arquitetura que favoreçam o melhor desempenho energético de Hotéis Econômicos ou de qualquer categoria. / This work aims to evaluate the energy efficiency and comfort level, in airconditioned environments of budget hotels, from international chains, in São Paulo, Brazil. The evaluation was directed to the apartments which are the hotels main product featuring air conditioning, even though the climate conditions and usage profile dont determine its need. One hotel from an international chain was chosen as a case study based on research of budget hotels main features. The hotel had its thermal performance evaluated through air temperature and humidity measurements, in two apartments, for five days. Its physical characteristics were inputted into the TAS NG (2005) software as a base model for simulations. The measurements results defined the criteria used in the parametric model, resulting in a total of seven scenarios with different characteristics such as glass, internal shades, ventilating rates and period. Considering São Paulos climatic conditions, the physical and occupational characteristics of the apartments, it was verified that it is possible to reach thermal comfort without the use of air conditioning. The evaluating criterion used in these conditions was an adaptive model from the ASHRAE 55 (2004) Norm. Data from the most representative days of summer and winter were used in the analysis. There was also an evaluation of the energy consumption of the air condition- ing system, used for cooling and heating purposes, for a period of one year. The results favored the proposal for project recommendations for this typology, seeking solutions to improve the capacity to harness the favorable natural conditions to obtain thermal comfort, allowing for energy consumption reduction due to air conditioning. To illustrate the recommendations some preliminary studies were prepared for the apartments and pavement type, considering the integration of the air conditioning system with architectural design solutions that favor a better energy performance of budget hotels or of any other category.

Page generated in 0.1032 seconds