231 |
Le gisement d’or du Tocantinzinho (province aurifère du Tapajós) relations entre déformation, hydrothermalisme et minéralisation / Tocantinzinho gold deposit (Tapajós Gold Province) relationship between deformation, hydrothermal alteration and mineralisationBorgo, Ariadne 23 February 2017 (has links)
Le gisement de Tocantinzinho est situé sur la province aurifère de Tapajós et est le plus grand gisement d'or de la province, avec 53,9 tonnes d'or estimées. Sa formation commence par un magmatisme granodioritique autour de 2005 Ma, suivi d'un magmatisme granitique. Le granite Tocantinzinho est composé de deux faciès principaux (syenogranite - 1996± 2Ma; monzogranite 1989±1 Ma), des corps d’aplite et de pegmatite, qui suggère un magmatisme enrichie en fluide et mis en place à faible profondeur. Intrusifs dans ces roches, des dykes d'andésite (1998±8Ma) ont des fragments de granite et des mélanges entre les 2 magmas suggèrent un magmatisme à la fois continu et polyphasé. Il est proposé que les premiers dykes d’andésite se sont mis en place alors que le granite n’était pas entièrement cristallisé (mingling) et les derniers lors des stades de déformation à l’état solide du granite. Utilisant la courbe de refroidissement, un âge minimum de 1975 Ma a été estimé pour l’andésite. Les taux de refroidissement des roches plutoniques varient de 3,6 à 14,7°C/Ma, avec une moyenne de 7,5°C/Ma, suggérant que les processus d'exhumation verticale sont faibles. La géométrie allongée du granite ainsi que la tectonique syn-magmatique de l'andésite corroborent la prédominance des mouvements horizontaux. L’affinité calc-alcaline fortement potassique et des anomalies en niobium définissent deux configurations possibles pour le cadre géotectonique: arc continental de type Andin ou Post-collisionnel. Compte tenue la relation génétique entre magmatisme, cisaillement décrochant et les faibles taux de refroidissement, l’environnement post-collisionnel est plus probable. Cela ensemble avec les âges nous permettent de comparer ces roches avec celles de la Suite Intrusive Creporizão (1997-1957Ma). La dacite (1992 ± 2 Ma) recoupe les autres roches, cependant, la signature géochimique comparable aux roches anorogéniques suggère qu’elle appartient à une série magmatique distinct. La zone minéralisée est limitée par deux failles majeures senestres de direction N100°-130E°. Le granite Tocantinzinho et les roches hypo-volcaniques déformées sont dans ce couloir, altérées par de fluides hydrothermaux et minéralisées pendant deux phases tectoniques distinctes. La première est caractérisée par des brèches et des microfractures remplies par muscovite (1864±5Ma) et pyrite, associées à de faibles teneur d’or (<1,5ppm) restreintes au granite. La deuxième phase a été contrôlée par le cisaillement décrochant senestre normal générant des fentes de tension et des brèches remplies par quartz, chlorite, calcite, albite, rutile, pyrite, galène, sphalérite, chalcopyrite et or. La teneur en or peut atteindre jusqu'à 70 ppm dans les veines riches en sulfures. Ces structures de remplissage syntectonique sont parallèles entre elles et orientées N30-60°E. Deux hypothèses ont été proposées pour expliquer la genèse du gisement: la première considère une relation génétique entre magmatisme et minéralisation au moins pour le premier stage de minéralisation selon un modèle porphyrique et la seconde alternative considère une réactivation des failles préexistantes par une tectonique transtensive liée au magmatisme Maloquinha (ca. 1880Ma) pour les deux stades minéralisateurs. Les deux phases dans les deux hypothèses, ont été classées comme des minéralisations de type magmato-hydrothermale qui pourraient être classées soit comme des systèmes d'or liés à l'intrusion. De nouveaux travaux sur le terrain et en laboratoire seraient nécessaires pour identifier et caractériser la nature et la source des fluides hydrothermaux, pour dater la minéralisation et mieux comprendre le rôle des roches hypo-volcaniques. Toutefois, les premiers résultats, et notamment le rôle fondamental du contrôle tectonique pour la minéralisation sont très significatifs et peuvent aider de manière conséquente à l'établissement des programmes d'exploration et d'exploitation futurs. / The Tocantinzinho deposit is located on the Tapajós Gold Province and is the largest gold deposit within Province, with 53,9 tons of gold. Its formation begins with a granodioritic magmatism around 2005Ma, followed by a granitic magmatism 10 Ma latter. The Tocantinzinho granite is composed by two main facies, syenogranite (1996±2Ma) and monzogranite (1989±1Ma), and by aplite and pegmatite bodies, suggesting a fluid-rich magmatism at shallow depth. Andesite dikes (1998±8Ma) are intrusive in both rocks. Sharp fragments of those rocks along contacts and minor mingling with granitic magma suggest a multiphase magmatism at distinct timing. The first dikes have intruded within granite when it was crystalizing, thus a minimum age of 1975Ma was estimated. Cooling rates of plutonic rocks vary from 3.6 to 14.7°C/Ma, with an average of 7.5°C/Ma, suggesting vertical exhumation processes were minor. The elongated geometry of granite along with sin-magmatic strike-slip tectonics of andesite corroborate the predominance of horizontal movements. Geochemical analysis show high-K calk-alkaline affinity and niobium anomaly indicator of two possible geotectonic settings for these rocks: Andean-type continental arc or post-collisional one. Considering the genetic relationship between magmatism, strike-slip faults, and low cooling rates, a post-collisional setting is more likely. The geochemical signature, ages and style of tectonism allow us to compare those rocks with the ones from Creporizão Intrusive Suite (1997-1957Ma). Dacite dikes (1992±2Ma) cut across all other rocks, but the temporal relationship among them remains misunderstood, due to the geochemical signature similar to the anorogenic rocks, suggesting it belongs to a distinct and latter magmatic series. Indeed, the dated zircons were probably inherited from host rocks. The mineralized area is restricted to a domain constrained by two major sinistral strike-slip N100°-130E°E faults that comprises the Tocantinzinho granite and sub-volcanic rocks, which were hydrothermally altered, brittle deformed and mineralized during two phases. The first one is characterized by breccias and microfractures infilled with muscovite (1864±5Ma) and pyrite, which contains low gold grades and are restricted to the Tocantinzinho granite. The second phase was controlled by strike-slip and normal tectonics generating tension gashes veins and pull apart breccias infilled with quartz, chlorite, calcite, albite, rutile, pyrite, galena, sphalerite, chalcopyrite, and gold. The gold grade can reach up to 70 ppm in some sulfide-rich veins. These structures are parallel and mainly trends N30-60°E, showing textures and orientated minerals typical of syn-tectonic infilling. Based on petrographical features and argon ages two hypothesis were proposed for the ore genesis: the first one consider a genetic relationship between magmatism and ore fluids for first mineralization stage and the second hypothesis consider a reactivation of pre-existing faults by an extensional tectonism related to the Maloquinha Intrusive Suite magmatism (ca.1880Ma) for this phase. The second mineralization phase is considered as formed as consequence of tectonic reactivation at ca. 1880Ma, in both hypothesis. Both phases in both hypothesis were classified as magmatic-hydrothermal ore mineralization and might be classified as intrusion-related gold systems. However, new field works are important in order to identify and characterize the nature and source of hydrothermal fluids, as well as ore dating and new geochemical and geochronological data of sub-volcanic rocks are imperative to better understand the genesis and evolution of the Tocantinzinho gold deposit. Such results, strongly linked to the fact that the tectonic control seem significant, may help for future exploration and exploitation programs.
|
232 |
Detecção de bactérias do gênero Legionella em amostras de água provenientes de sistemas de ar condicionado / Detection of bacteria genus Legionella in water samples of airconditioning systems [master degree]Etto, Helder Yudji 16 June 2009 (has links)
Introdução: Destaca-se a importância dos organismos do gênero Legionella como agentes causadores de doenças do aparelho respiratório como a legionelose ou doença do Legionário, e ainda de um controle na manutenção adequada de sistemas de ar condicionado, uma vez que estes foram identificados como ambientes favoráveis à proliferação desses microrganismos. Objetivo: Devido à importância de bactérias do gênero Legionella como agentes causadores de doenças, e um crescente número de casos de legionelose relacionados à permanência em ambientes fechados, este estudo teve como objetivo determinar a presença de Legionella em águas de bandejas de sistemas de ar condicionado. Métodos: Foram realizadas análises de amostras de água provenientes de bandejas de ar condicionado de dois hospitais, uma instituição de ensino superior e um centro comercial, totalizando 41 amostras. Volumes de 1L das amostras coletadas foram concentrados em membrana, seguida de tratamento ácido. Alíquotas das amostras tratadas e não tratadas com ácido, foram então inoculadas em meio Agar BCYE-, com e sem adição de antibióticos. As cepas isoladas foram submetidas a teste sorológico para identificação. Resultados: Das amostras analisadas, 4 (9,5%) apresentaram resultado positivo para Legionella sp.; uma no centro comercial e três em um dos hospitais estudados. Os isolados foram submetidos a teste sorológico, sendo um identificado como Legionella pneumophila sorogrupo 1 e três como seis prováveis espécies:L. longbeachae, L. bozemanni, L. dumoffi, L. gormanii, L. jordanis, L. micdadei, L. anisa . Conclusão: Os resultados deste estudo comprovam a presença de Legionella sp. nos sistemas de ar condicionado pesquisados, sendo observada maior freqüência dos isolados em amostras analisadas oriundas dos hospitais.Os resultados demonstraram a importância e a necessidade de planos de monitoramento em sistemas de 7 ar condicionado como medida preventiva à colonização por organismos patogênicos nesses sistemas e dessa forma proteger a saúde dos ocupantes e usuários de ambientes climatizados artificialmente. / Introduction: It highlights the importance of organisms genus Legionella as responsible for diseases of the respiratory system such as legionellosis or Legionnaires´disease, and a control on proper maintenance of air conditioning systems, as these were identified as favorable environment for the proliferation of these microorganisms. Objective: Due to the importance of Legionella as causative agents of disease and a growing number of cases of legionellosis related to stay indoors, this study aimed to determine the presence of Legionella in water samples from air-conditioning systems. Methods: We performed analysis of samples of water from trays of airconditioning systems in two hospitals, a university and a trade center, totalizing 41 samples. One liter volumes of water samples were concentrated on membrane, followed by acid treatment. Aliquots of the sample treated and not treated with acid, were inoculated on BCYE- agar medium, with and without added antibiotics. The strains were subjected to serological identification. Results: Out of the samples analyzed, 4 (9.5%) were positive for Legionella sp.; one in a trade center and three in one of the hospitals. Isolates were submitted to serological testing, one identified as Legionella pneumophila serogroup 1 and three as probable six species: L. longbeachae, L. bozemanni, L. dumoffi, L. gormanii, L. jordan, L. micdadei, L. anise. Conclusion: The results confirm the presence of Legionella sp. in air conditioning systems studied. It was observed a higher frequency in isolates from hospitals. The results demonstrated the importance and necessity of monitoring plans in air-conditioning systems as a preventive measure to colonization by pathogens in these systems and protect the health of occupants and users of these buildings.
|
233 |
Análise do material particulado atmosférico em uma região de São Carlos-SP / Analysis of atmospheric particulate matter in a region of São Carlos-SPVálio, Vinícius Mori 29 May 2015 (has links)
O presente trabalho avaliou a qualidade do ar de uma área central da cidade de São Carlos-SP, mais precisamente no campus 1 da Universidade de São Paulo. Nessa região há grande movimentação de pessoas e veículos, principalmente durante o horário comercial. Esta avaliação foi feita com base na determinação de um dos parâmetros utilizados para verificar a qualidade do ar, o material particulado (MP) inalável em suspensão, ou seja, partículas que possuem diâmetro aerodinâmico menor ou igual a 10 μm e podem penetrar no sistema respiratório, sendo portanto, nocivas à saúde humana. O MP foi determinado em suas frações de 2,5 e 10 μm de diâmetro (MP10 e MP2,5). Duas metodologias diferentes foram utilizadas para determinar a concentração do material particulado em suspensão, fotometria por espalhamento de luz, através do equipamento ADR-1500 e gravimetria, através do PEM (Personal Enviromental Monitor). Os valores obtidos pelo método gravimétrico foram superiores aos resultados encontrados através da fotometria. As concentrações obtidas foram comparadas com os limites recomendados pela Organização Mundial da Saúde para o MP em suas frações de 2,5 e 10 μm, iguais respectivamente a 25 e 50 μg/m3. Além do material particulado foram obtidos dados para temperatura, umidade relativa e precipitação. As médias obtidas para as concentrações de MP10 e MP2,5, com o método gravimétrico, o qual fornece os resultados mais confiáveis, foram iguais respectivamente a 48,8 e 23,1 μg/m3, muito próximas portanto, de seus limites correspondentes. As menores concentrações obtidas para o MP10 foram, em sua maioria, verificadas em dias chuvosos, tanto através do PEM como do ADR. As concentrações de MP2,5, obtidas somente através do PEM, também apresentaram os menores valores em dias com chuva. Foi desenvolvido um modelo matemático que prevê o comportamento do MP10 durante as precipitações, evento este que se mostrou o mais importante na influência da concentração de material particulado atmosférico. / This study evaluated the air quality of a central area of the city São Carlos-SP, more precisely on the Campus 1 of the University of São Paulo. In this region there is a large movement of people and vehicles, manly during business hours. This evaluation was made based on determination of one parameter used to verify air quality, the inhalable particulate material (PM) suspended in the air, in other words, particles which have aerodynamic diameter less or equal to 10 μm and can penetrate in the respiratory system, therefore, harmful to human health. The PM was determined in its fractions from 2,5 and 10 μm of diameter (PM10 e PM2,5).). Two different methodologies were used to determinate the concentration of particulate suspended material, photometry by scattered light, using the equipment ADR-1500, and gravimetry, thru PEM (Personal Environmental Monitor). The data obtained from gravimetry were higher than the results found thru photometry. The concentrations found were compared to the limits recommended by World Health Organization for PM and its fractions of 2,5 and 10 μm, equal to 25 and 50 μg/m3. Besides PM, temperature, relative humidity and precipitation were measured. The average values for the concentrations of PM10 and PM2,5 , using gravimetry, which provide more reliable results, it were equal to 48,8 and 23,1 μg/m3, therefore really close to their corresponding limits. The lower concentrations seen for PM10 were, mostly, verified on rainy days, using PEM and ADR. The concentrations of PM2,5 , obtained just using PEM, also had the lowest values during rainy days. A mathematical model was developed to predict PM10 behavior during precipitations, this event has shown to have the most important influence on the concentration of atmospheric particulate matter.
|
234 |
Estudo da influência da camada limite hidrodinâmica no desempenho de um tanque vertical de termoacumulação de água gelada durante o ciclo de descarga. / Study of the hydrodynamic boundary layer in the performance of a vertical cold water thermal storage tank during the discharging cycle.Milaré, Manoel Máximo 15 December 2008 (has links)
Quando água quente é introduzida em um tanque de termoacumulação vertical, durante o ciclo de descarga, ocorre uma mistura parcial dessa água com a água fria armazenada. A intensidade dessa mistura depende de parâmetros geométricos do difusor de entrada e da dinâmica do escoamento no início do processo. Inúmeros estudos têm sido desenvolvidos no intuito de se projetar adequadamente o difusor de entrada, de forma a minimizar essa mistura, que corresponde a uma perda de capacidade do tanque. Porém, há uma outra forma de perda de capacidade do tanque, devida aos efeitos viscosos do escoamento. Quando um fluido escoa dentro de um tubo, há a formação de uma camada limite hidrodinâmica, devida à viscosidade do mesmo. Na região do comprimento hidrodinâmico de entrada, em cada seção transversal do tubo e dentro da camada limite, os efeitos viscosos geram um gradiente (radial) de velocidade. Fora dessa camada (no núcleo), esses efeitos são desprezíveis e o fluido escoa com velocidade uniforme. Porém, ao longo desse comprimento, o movimento do fluido no núcleo é acelerado. O escoamento em um tanque vertical de termoacumulação ocorre na região do comprimento hidrodinâmico de entrada. Considerando que não haja mistura das massas de água quando se inicia a introdução da água quente, irá se forma uma superfície de contato entre as mesmas. Essa superfície, por possuir velocidade no núcleo maior que a velocidade média de descarga, atingirá o difusor de saída mais rapidamente. Assim, para que seja garantida descarga de água na temperatura da água armazenada durante todo o ciclo de descarga, a altura do tanque deverá ser maior que a altura determinada utilizando-se a velocidade média do escoamento, sem considerar os efeitos viscosos (modelo ideal). A diferença entre essas alturas constitui, por si só, uma perda de capacidade do tanque. O estudo dos efeitos do escoamento viscoso no desempenho do tanque mostra que dois números adimensionais surgem naturalmente: o número de Reynolds relativo ao diâmetro, ReØ, necessário para se determinar o comprimento hidrodinâmico de entrada, e o número f, que relaciona a posição da superfície de contato das massas de água com o comprimento hidrodinâmico de entrada. Os resultados mostram que a perda devida aos efeitos do escoamento viscoso pode não ser desprezível e que a escolha do diâmetro do tanque é de fundamental importância para minimizar esses efeitos. Também, a análise qualitativa do escoamento sugere que as perdas de capacidade do tanque nos ciclos de descarga e carga não são iguais, pois a diferença de densidade das massas de água age de maneira diversa em cada caso. / When warm water is introduced into a vertical thermal storage tank, during the discharging cycle, a partial mixing between it and the cold water stored will occur. The extension of that mixing depends upon diffuser geometric parameters and the dynamics of the flow at the beginning of the process. So many works have been developed, trying to find the better diffuser design so that undesired mixing can be minimized. The mixing is accounted as a tank loss of capacity. But, there is another kind of tank loss of capacity due to viscous effects of the flow. When a fluid flows inside a tube, it forms a boundary layer due to fluid viscosity. At the hydrodynamic entry length region, in each cross section of the tube and inside the boundary layer, the viscous effects create a (radial) velocity gradient. Outside of the boundary layer (inside the core), the viscous effects are negligible and the fluid flows with a uniform velocity. However, along the entry length that velocity gets higher at each section. In a vertical thermal storage tank, water flows at the hydrodynamic entry length region. Considering that no mixing occurs at the beginning of the warm water introduction at the tank top, it will form a contact surface between the warm water and the cold one already in the tank. That contact surface has the velocity inside the core higher than the mean discharging flow velocity and it will reach the outlet diffuser at the tank bottom more quickly. Then, the tank height must be greater than that determined using the mean velocity flow alone without any viscous effect (ideal model), so that the discharging flow has the same stored water temperature during all the discharging cycle. The difference between those heights constitutes itself a tank loss of capacity. The study of the viscous effects on the tank performance shows that two non-dimensional parameters appear naturally: the Reynolds number related to the tank diameter, ReØ, used for determining the hydrodynamic entry length, and the f number that relates the position of the contact surface of the water masses to the hydrodynamic entry length. Results show that the loss due to viscous effects, may not be negligible and the choice of the tank diameter is essential to minimizes those effects. Also, there is a difference between tank losses of capacity during the charging and discharging cycles, since the effect of the density difference between the warm and cold water works in a different way in each one of those two situations.
|
235 |
Avaliação da evolução e estratégias para controle da concentração do dióxido de carbono em uma sala de aula /Odisi, Francisco, 1958-, Reinehr, Edelberto Luiz, 1957-, Noriler, Dirceu, 1978-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Química. January 2013 (has links) (PDF)
Orientador: Edelberto Luiz Reinehr. / Co-orientador: Dirceu Noriler. / Dissertação (mestrado) - Universidade Regional Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Química.
|
236 |
Proposição e avaliação de medidas de controle de material particulado em um processo de eletrofusão / Proposition and evaluation of particulate matter control measures in a process of electrofusionCôrtes, Mariana Wached de Paiva 21 December 2015 (has links)
O processamento de materiais sólidos gera emissão e suspensão de material particulado, por este motivo, as indústrias vêm fazendo maiores investimentos na prevenção e minimização de emissões, revertendo essas perdas em lucros, diminuindo suas perdas, utilizando a proteção ambiental como um instrumento de marketing, aumentando a competitividade da empresa no mercado. A motivação deste projeto vem justamente da necessidade de mitigação da emissão de particulados de uma indústria que utiliza o processo de eletrofusão em seu sistema produtivo, pois há fuga de material particulado durante o processo. O objetivo principal do projeto consiste na análise de eficiência do sistema de exaustão para orientação de proposições de melhorias no mesmo. Foram determinados 4 pontos de coleta de amostra de maneira que representasse todo o processo, as amostras foram coletadas 3 vezes por dia, durante 5 dias. Foram feitas a caracterização química, utilizando fluorescência de raio-x e física utilizando a técnica de espalhamento de luz no equipamento Malvern. Posteriormente foi feita a elaboração das curvas de distribuição granulométricas para determinação do diâmetro de corte do ciclone. Para avaliação do sistema de exaustão foi calculada a eficiência do ciclone através do balanço de massa e através do ajuste de modelo RRB linear e não-linear calculados através do resultado de análise granulométrica. A conclusão foi de que é necessário fazer melhoria no ciclone para que haja melhoria no sistema de exaustão da empresa e redução da perda e emissão de material particulado. As análises orientaram o redimensionamento do ciclone. / The processing of solid materials generates emission and suspension of particulate matter - for this reason industries are making major investments in prevention and minimization of emissions, returning those losses into profits by reducing their losses, using environmental protection as a marketing tool, increasing the company's competitiveness in the market. The motivation of this project right comes from the need to mitigating the particulate emissions of an industry that uses the electrofusion process in its production system because there is escape of particulate matter during the process. The main objective of the project consists in analyzing the efficiency of the exhaustion system to guide improvement propositions in it. Four representative sampling points were, samples were collected three times a day during 5 days. Chemical and physical characterization were made by using x-ray fluorescence and with light scattering technique with the Malvern equipment, respectively. After that, the particle size distribution curves were traced so the cyclone cut diameter could be determined. In order too evaluate the exhaustion system it was calculated cyclone efficiency by mass balance; by using the RRB parameters adjusted by linear and nonlinear model adjustment using the results of particle size analysis. The conclusion was that it is necessary to improve the cyclone in order to improve the exhaustion system efficiency reducing the loss and emission of particulate matter. The analyzes guided the resizing of the cyclone.
|
237 |
A trade-off study of a bleedless and conventional air conditioning systems.Victor Crespo Cavalcanti 03 April 2008 (has links)
The objective of this work is to present a trade-off study between aircraft air conditioning systems based on conventional technology (Engine Pneumatic Bleed based) and the proposed bleedless architecture, based on the MEA (More Electric Aircraft) and Bleedless Engines concepts. The pneumatic bleed system components are thus eliminated and a dedicated compressor serves as the main power supply to the air conditioning and pressurization system. Both the conventional and the proposed ECS architecture are described and the system main parameters are calculated. The aircraft used as baseline for the study is the RJ2, a 50 seats regional jet, designed as an academic exercise during the PEE ITA/EMBRAER program. Since the aircraft' requirements - determined by the PEE coordination - were for a regional jet, operational characteristics and aspects of costs, weight, energy efficiency, maintainability and impacts on other systems of the aircraft were considered. The proposed air conditioning architecture is compared to a conventional one in terms of weight, system price and power and fuel consumptions. This work is merely academic and conceptual and does not involve any existing or in development aircraft data from EMBRAER or any other aircraft or system manufacturer.
|
238 |
Estudo experimental sobre combustão sem chama visível com baixa temperatura de pré-aquecimento de arFernando Lima de Oliveira 05 December 2012 (has links)
O regime de combustão sem chama visível ou flameless na língua inglesa é obtido pela mistura de gases de combustão quentes em recirculação com os reagentes, permitindo condições de flamabilidade e ignição distribuída por todo o volume do combustor. Este regime de combustão vem despertando interesse devido às indicações de que sua aplicação pode oferecer diversas vantagens, tais como, redução da emissão de gases de oxidação parcial, especialmente do NOx e CO, diminuição de picos de temperaturas, tendência à uniformidade da temperatura no volume das câmaras, capacidade do uso de ar pré-aquecido e ainda a economia de combustível. A execução de um projeto de um estudo experimental usando uma câmara e um queimador do tipo flameless foi conduzido com o objetivo de investigar as características deste regime de combustão, avaliar o campo de temperatura ao longo da câmara e a concentração de gases de exaustão. A bancada do sistema de escala laboratorial operou com gás natural veicular (GNV) e com ar comprimido pré-aquecido. Os experimentos foram conduzidos com uma vazão fixa de 0.16 g/s de GNV e ar comprimido à temperatura de 250 C. O sistema de monitoramento e aquisição de dados foi desenvolvido utilizando o software de instrumentação LabVIEW. Os resultados indicam que para algumas condições foi possível alcançar o regime flameless resultando numa redução significativa da produção de NOx e CO.
|
239 |
Efeitos da poluição do ar sobre a função pulmonar: um estudo de coorte em crianças de Cubatão / Effects of air pollution on lung function: a cohort study in Cubatão childrenHofmeister, Vera Anna 11 September 1991 (has links)
É feita a análise da evolução de provas funcionais ventilatórias de dois grupos de crianças clinicamente sadias, residentes no Município de Cubatão, examinadas inicialmente em dois estudos transversais realizados respectivamente em 1983 (verão) e em 1985 (inverno). O princípio epidemiológico que norteou essa pesquisa foi a realização de um estudo de Coorte Não-Controlada, ou mais apropriadamente, um Estudo Ecológico Longitudinal, onde esses dois grupos de crianças foram anualmente submetidos a exames espirométricos no período de 1987 a 1989, mantida a estrita sazonalidade, ou seja, o Grupo de 1983 foi sempre reexaminado no verão, enquanto que o Grupo de 1985 sempre no inverno. Aproximadamente 1.110 crianças, oriundas de todas as áreas do Município foram submetidas a provas de função pulmonar utilizando-se espirômetro seco, com especial ênfase na análise do comportamento da Capacidade Vital Forçada (CVF), do Volume Expiratório Forçado no Primeiro Segundo (VEF1,0), do \"Peak-Flow\" ou Pico de Fluxo Expiratório (PFE), e do Fluxo Médio Expiratório Forçado (FMF25-75 por cento ), todos considerados como indicadores sensíveis às influências dos níveis de poluição atmosférica registrados em Cubatão. As informações concernentes à poluição do ar foram obtidas através dos relatórios de pesquisas efetuadas pela Companhia de Tecnologia de Saneamento Ambiental do Estado de São Paulo (CETESB) e envolveram a análise das estimativas de emissões das indústrias prioritárias de Cubatão, das concentrações horárias de material particulado (MP), dióxido de enxofre (SO2) e do ozona (O3) registradss nas estações amostradoras de Vila Parisi, Cubatão-Centro e Vila Nova no período de Novembro de 1983 a Dezembro de 1989. Também integrou o contexto de análise, a avaliação das principais metas do Programa de Controle de Poluição do Ar instituído pela CETESB na região a partir de 1984, com o objetivo de se verificar se as reduções pretendidas nos níveis de poluição do ar se fizeram acompanhar de melhorias nas provas funcionais pulmonares das crianças estudadas. Verificou-se que os episódios agudos de poluição do ar, principalmente devidos ao material particulado, mostraram algum decréscimo. No entanto, aqueles devidos a oxidantes fotoquímicos, representados pelos níveis de ozona, tiveram progressivo incremento no período de 1984 a 1988, tanto em relação ao número de episódios, como na persistência e gravidade dos mesmos. Os resultados espirométricos indicaram que em ambos os grupos de crianças a função pulmonar mostrou decrementos significativos, com perdas em tomo de 5 a 8 por cento ao ano, em média, quando comparados com os valores inicialmente registrados por ocasião dos estudos transversais. Apesar das reduções terem sido observadas em todas as variáveis espirométricas, os maiores decrementos verificaram-se principalmente nas medidas de fluxo (PFE e FMF25_75 por cento ), e coincidiram com o ano em que foram assinalados os mais graves episódios de poluição devida a oxidantes fotoquímicos. Os bairros Cota 95, Cota 200, Jardim das Indústrias e Vila Natal, localizados na área de influência do núcleo industrial químicofpetroquímico sobressairam-se como os mais críticos em função dos piores resultados espirométricos apresentados ao longo de todo o estudo. Pôde-se concluir que apesar da função pulmonar das crianças ainda não ter atingido níveis considerados como patológicos, mesmo registrando valores inferiores aos limites da normalidade nas variáveis de fluxo no ano de 1988, verificou-se que de ano para ano a função pulmonar vem decrescendo progressivamente indicando que esta vai sendo afetada pela exposição as poluentes da região e que as medidas de controle da poluição instituídas em Cubatão não tiveram a eficácia esperada. Continuando nessa mesma trajetória evolutiva, isso poderá acarretar sérios e irreparáveis prejuízos à saúde da população. É necessário, portanto, a adoção de urgentes medidas para a melhoria da qualidade do ar em Cubatão nos anos futuros, no intuito de prevenir sérios agravos à Saúde Pública. / The purpose of this study was to investigate the effects of exposure to air pollution on lung function of children. Two groups of clinically healthy children, living at different areas of the city of Cubatão, who had been submitted to lung function tests in a previous cross-sectional study (1983 summertime and 1985 wintertime) were annually reexamined using the same type of test during the period 1987 to 1989. On epidemiological basis this is a longitudinal study, where every individual of the two groups of children was measured at each ocasion, always in the same season of the previous examination. About 1,110 children from all areas of the city were examined once a year using dry spirometer, with special emphasis on FVC, FEV 1,0, PEF and FMF25-75 per cent measurements, since they were considered as those which could be most affected by the local air pollution. Information regarding the conditions of air pollution were obtained from the CETESB\'s written reports. They include the estimate emissions of the main industries of the region; the hourly concentrations of particulate matter, sulfur dioxide and ozone measured in the sampling stations located in Vila Parisi, Cubatão-Centro and Vila Nova during the October/1983 to December/1989 period and also the results of the Source Control Strategy introduced by CETESB since 1984. It was observed that the acute episodes of air pollution due to PM were reduced in number. However, those due to photochemicaf oxidants, mainly represented by ozone leveis, were progressively more frequent during the period from 1984 to 1988; both their number and their severity increased during this period. Spirometric results shows that in both groups of children the lung function was significantly impaired, with losses of 5 to 8 per cent per year, when compared with the initial values of the cross-sectional studies. Despite the fact that all lung function parameters decline, the flow (PFE and FMF2s-7s per cent ) values were those most affected and closely related to the most serious episodes of air pollution due to photochemical oxidants mainly those observed in 1988. Children living in the areas of Cota 95, Cota 200, Jardim das Indústrias and Vila Natal, situated in the nearest area of influence of the chemical and petrochemical industries, presented worst spirometric results than children living in other places of Cubatão. The lung function of the examined children did not attain pathological values, despite the fact of presenting the worst results in flow parameters during the year of 1988. It was observed that their lung function is progressively impaired year by year, a clear indication of the progressive effects of air pollution on their lung function, and if such impairment continues there will carne the time when lung function will probably reach a pathologicallevel. It is concluded that there is an urgent need of improving the quality of air of Cubatão to avoid serious Public Health problems in a quite near future.
|
240 |
Concentração do ozônio em dois sítios experimentais da região metropolitana de Manaus: Medidas convencionais e estimativas remotasCosta, Patrícia dos Santos 30 October 2015 (has links)
Submitted by Inácio de Oliveira Lima Neto (inacio.neto@inpa.gov.br) on 2016-08-22T15:16:18Z
No. of bitstreams: 2
DissertOficial_PATRICIACOSTA (1).pdf: 3783880 bytes, checksum: 6fce8dcbf21983cf77c96c6527db4a03 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-08-22T15:16:18Z (GMT). No. of bitstreams: 2
DissertOficial_PATRICIACOSTA (1).pdf: 3783880 bytes, checksum: 6fce8dcbf21983cf77c96c6527db4a03 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2015-10-30 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The purpose of this study is to evaluate the behavior of the concentration of tropospheric ozone (O 3 ) daily and seasonally by the influence of meteorological variables and burning outbreaks inthe region. In addition, it seeks to study the feasibility of using remote information for monitoring air quality. The data used in surface contemplated observations, obtained by the measures of air quality stations and altitude, based on satellite data AQUA. Surface data was the period of October / 2013 to July / 2014 and August / 2014 to October / 2014 to the experimental sites located in the city of Manaus and Manacapuru (Amazonas State), consecutively. Data from satellite inferences AQUA match climatology of estimates of ozone concentration 2003 to 2014. And in particular, the case studies contemplated day 09 to 11.11.2013 and 07.20.2015 (for Manaus) and the ranges of 30-31 / 11/2014 and 29 to 11/30/2014 for the city of Manacapuru.Statistical tools were used as means of analysis and deviations to assess the empirical data distribution and additionally we used the thresholds of the laws of the largest national and
international importance of air quality as control parameters. The results showed significant differences in the concentrations found in the experimental sites of this study. Various events show that the concentration of ozone, during the dry season in the region, beyond the existing air quality thresholds, sometimes extending into the early hours of the night. In this sense becomes worrisome the fact that in the dry season there is the intensification and frequency of events that lead to ozone accumulation in surface, which are modulated by the rainfall regime, solar radiation, predominantly wind and external factors such as local fires to favor the production of ozone precursors. Furthermore, remote estimates also showed a significant difference between dry season and rain in the region, and even being underestimated in relation to the measures in surface, they present themselves as an important tool in monitoring the ozone concentration in surface and altitude over areas of difficult access. / O propósito deste estudo foi avaliar o comportamento da concentração de ozônio troposférico
(O 3 ) diariamente e sazonalmente mediante a influência de variáveis meteorológicas e focos de
queima na região metropolitana de Manaus. Além disso, buscou-se estudar a viabilidade de se
utilizar informações remotas para o monitoramento de qualidade do ar. Os dados utilizados
contemplaram observações em superfície, obtidas através das medidas das estações de
qualidade do ar, e em altitude, baseados nos dados do satélite AQUA. Em superfície o período
de dados foi de outubro/2013 a julho/2014, e agosto/2014 a outubro/2014 para os sítios
experimentais localizados na cidade de Manaus e Manacapuru (Estado do Amazonas),
consecutivamente. Os dados provenientes das inferências do satélite AQUA correspondem à
climatologia das estimativas da concentração de ozônio de 2003 a 2014. E em especial, os
estudos de caso contemplaram os dias 09 a 11/11/2013 e 20/07/2015 (para Manaus) e os
intervalos de 30-31/11/2014 e 29 à 30/11/2014 para o município de Manacapuru. Foram
utilizadas ferramentas estatísticas, como análise de médias e desvios para avaliar a distribuição
empírica dos dados e adicionalmente foram utilizados os limiares das legislações de maior
importância nacional e internacional de qualidade do ar como parâmetros de controle. A
análise dos resultados mostrou uma diferença significativa das concentrações encontradas nos
sítios experimentais deste estudo. Diversos eventos mostraram que a concentração de ozônio,
durante o período seco na região, ultrapassaram os limiares de qualidade do ar vigentes,
algumas vezes estendendo-se até as primeiras horas da noite. Neste sentido torna-se
preocupante o fato de que na estação seca exista a intensificação e frequência dos eventos que
levam ao acúmulo de ozônio em superfície, sendo estes modulados pelo regime de
precipitação, radiação solar incidente, predominância dos ventos e fatores externos como
queimadas locais que favorecem a produção de precursores de ozônio. Ademais, as
estimativas remotas também mostraram uma diferença expressiva entre as estações de seca e
chuva na região, e mesmo sendo subestimadas em relação às medidas em superfície, as
mesmas apresentam-se como uma importante ferramenta no monitoramento da concentração
de ozônio em superfície e em altitude sobre regiões de difícil acesso.
|
Page generated in 0.0323 seconds