• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 23
  • 23
  • 23
  • 23
  • 12
  • 10
  • 1
  • 1
  • 1
  • Tagged with
  • 61
  • 61
  • 19
  • 15
  • 13
  • 10
  • 10
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Investigação analítica do processo de lixamento em relação às características do acabamento superficial do Corymbia citriodora & Pinus elliottii /

Leite, Sueli Souza. January 2019 (has links)
Orientador: Ivaldo De Domenico Valarelli / Coorientador: Manoel Cléber de S. Alves / Banca: João Eduardo Guarnetti dos Santos / Banca: Marcos Tadeu Tiburcio Gonçalves / Banca: Marcus Antonio Pereira Bueno / Resumo: As madeiras tratadas termicamente podem ser processadas, coladas ou pintadas, sendo empregadas na confecção de diversos produtos como: decks, esquadrias, armários internos, painéis decorativos, pisos, móveis dentre outros, que necessitam muitas vezes em seu processo de fabricação passar pelo lixamento. Tal processo consiste em adequar as dimensões desejadas da peça e proporcionar o seu acabamento superficial, padrão fundamental para qualidade do produto que afeta tanto a questão estética quanto na aplicação de revestimentos. No entanto, o lixamento é oneroso por ser realizado empiricamente nas industrias, sem padronização. Sabendo-se disto, foi realizado uma investigação estatística do processo de lixamento da madeira aplicando dois métodos experimentais, fatorial completo e de Taguchi, afim de analisar o comportamento da rugosidade média e dos parâmetros de controle do processo potência e vibração. Para obtenção dos dados utilizou um sistema de monitoramento composto por uma lixadeira plana com circuito pneumático, no qual variou os fatores espécie de madeira Corymbia citriodora e Pinus elliottii, granulometria das lixas de óxido de alumínio de 100, 120, 150 e 220 mesh e o gradiente de temperatura do tratamento térmico das madeiras de 80,120,160 e 200°C, incluindo também no processo madeiras sem tratamento térmico de ambas as espécies mencionadas. Os dados foram analisados estatisticamente por meio de análise de variância - ANOVA, teste de comparações múltiplas de Tukey com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The heat treated woods can be processed, glued or painted, being used in the manufacture of various products such as decking, frames, interior cabinets, decorative panels, floors, furniture and others, which often require in their manufacturing process to go through sanding. This process consists in adjusting the desired dimensions of the part and providing its surface finish, a fundamental standard for product quality that affects both the aesthetic issue and the application of coatings. However, sanding is costly because it is performed empirically in industries without standardization. Knowing this, a statistical investigation of the wood sanding process was carried out applying two experimental methods, complete factorial and Taguchi, in order to analyze the average roughness behavior and the control parameters of the power and vibration process. To obtain the data we used a monitoring system consisting of a flat sander with pneumatic circuit, which varied the species Corymbia citriodora and Pinus elliottii, the size of the 100, 120, 150 and 220 mesh aluminum oxide sandpaper and temperature gradient of the wood heat treatment of 80,120,160 and 200°C, also including in the process wood without heat treatment of both species. Data were statistically analyzed by analysis of variance - ANOVA, Tukey's multiple comparisons test with 95% reliability and multiple regression using the R® and Minitab 18 ® software. After the analysis, it can be concluded that Pinus elliotti has no ... (Complete abstract click electronic access below) / Doutor
22

Efeito da temperatura de ataque químico na superfície da liga ti6al4v usada em aplicações biomédicas /

Alberti, Charles Jourdan. January 2018 (has links)
Orientador: Adriano Gonçalves dos Reis / Coorientador: Eduardo Saito / Banca: Rodrigo Máximo de Araújo / Banca: João Paulo Barros Machado / Resumo: A modificação da superfície dos implantes é alvo de inúmeros estudos com o intuito de desenvolver alterações microestruturais no titânio e suas ligas que possam acelerar o processo de osseointegração. O futuro da implantodontia está atualmente vinculado a estas futuras descobertas. O titânio e suas ligas são amplamente utilizadas em aplicações biomédicas devido às suas propriedades de biocompatibilidade e mecânicas. Assim, o objetivo deste trabalho é avaliar o efeito nas propriedades físico-químicas de superfície da liga de Ti6Al4V após o ataque com solução piranha nas temperaturas de 25 °C, 40 °C e 60 °C num tempo constante de 30 min. Para caracterização da superfície foram utilizadas as técnicas de microscopia eletrônica de varredura com espectroscopia de energia dispersiva de raios X, perfilometria óptica, difração de raios X e molhabilidade. Além disso foram realizados ensaios de corrosão por polarização potenciodinâmica e espectroscopia de impedância eletroquímica. Os resultados demonstraram que é possível alterar a textura, a rugosidade da superfície e a resistência à corrosão da liga com a variação da temperatura de ataque químico. O tratamento de superfície proposto não alterou a molhabilidade, que se manteve hidrofílica, nem a química da superfície, que se manteve formada principalmente por TiO2 amorfo. A rugosidade e a área da superfície aumentaram exponencialmente com o aumento da temperatura, que pode estar relacionado com o aumento da cinética de reação. Pôde-se ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The surface's modification of the implants is the subject of numerous studies with the intention of developing microstructural changes in titanium and its alloys that can accelerate the osseointegration process. The future of implantology is currently linked to these future discoveries. Titanium and its alloys are widely used in biomedical applications because of their biocompatibility and mechanical properties. Thus, the objective of this work is to evaluate the effect on the surface physicochemical properties of the Ti6Al4V alloy after the piranha solution attack at temperatures of 25 °C, 40 °C and 60 °C at a constant time of 30 min. To characterize the surface were used the techniques of scanning electron microscopy with dispersive energy X-ray spectroscopy, optical profilometry, X-ray diffraction and wettability. In addition, corrosion tests were carried out by potentiodynamic polarization and electrochemical impedance spectroscopy. The results showed that it is possible to change the texture, surface roughness and corrosion resistance of the alloy with the variation of the etching temperature. The proposed surface treatment did not alter the wettability, which remained hydrophilic, nor the surface chemistry, which remained mainly amorphous TiO2. Roughness and surface area increased exponentially with increasing temperature, which may be related to the increase in reaction kinetics. It was possible to obtain a sponge-like threedimensional texture with formation of nano an... (Complete abstract click electronic access below) / Mestre
23

Estudo da rugosidade e da morfologia superficial do esmalte de dentes decíduos submetidos a diferentes métodos profiláticos /

Oliveira Netto, Arlindo Carvalho. January 2018 (has links)
Orientador: João Carlos Rocha / Coorientador: Ivan Balducci / Banca: João Paulo Barros Machado / Banca: José Benedito Oliveira Amorim / Resumo: O controle da doença cárie é um dos maiores desafios na Odontologia. O controle do biofilme, de forma mecânica pelo paciente ou pelo profissional, ainda é o melhor método preventivo Este trabalho tem como objetivo a realização de um estudo in vitro da rugosidade do esmalte de dentes decíduos submetidos a quatro métodos profiláticos diferentes. Selecionamos 32 faces proximais de dentes decíduos hígidos, que foram divididos em 4 grupos. No primeiro grupo utilizamos para o polimento mistura de pedra-pomes (SSWHITE)® e água destilada e realizamos polimento utilizando taça de borracha em caneta de baixa rotação; no segundo, pasta profilática Clinpro Prophy Paste (3M)®também com taça de borracha em caneta de baixa rotação; no terceiro jato de bicarbonato de sódio (Polident) e no quarto jato de glicina Clinpro Prophy Powder(3M). Todos os procedimentos foram realizados pelo mesmo operador, que foi calibrado na busca de reprodução de situação clínica. Em cada espécime os procedimentos foram realizados durante 10 segundos com os produtos e equipamentos determinados. Após os procedimentos profiláticos os dentes foram lavados e armazenados em água destilada até o momento das leituras. As leituras para mensuração da rugosidade superficial em micrometros foram realizadas antes e após os procedimentos profiláticos por meio do Perfilômetro Óptico Wyko NT1100 INPE. Todos os grupos provocaram um aumento do valor de Rugosidade aritmética Ra, que é a rugosidade provocada por picos e vale do esmalte de dentes decíduos, sendo que o grupo 4 do (bicarbonato) que apresentou melhores resultados por apresentar menor variação em analise estatísticas, através da ferramenta teste t-Student mostrou que não houve variação de Ra inicial entre os 4 grupos / Abstract: Caries disease control is one of the greatest challenges in dentistry. The biofilm control mechanically by the patient or by the professional is still the best preventive method. This work aims to perform an in vitro study of the enamel roughness of deciduous teeth submitted to four different prophylactic methods. We selected 32 faces close to healthy deciduous teeth, which were divided into 4 groups. In the first group we used a mixture of pumice (SSWHITE) ® and distilled water polishing with rubber cup in a low rotation pen; in the second group we used Clinpro Prophy Paste (3M) ® prophylactic paste also with rubber cup in low rotation pen, in the third group the polishing with sodium bicarbonate jet (Polident) and in the fourth group with glycine jet Clinpro Prophy Powder (3M ). All procedures were performed by the same operator properly calibrated for 10 seconds with parameters controlled after the prophylactic procedures the teeth were washed and stored in distilled water until readings. The readings for measuring surface roughness in micrometers will be performed before and after the prophylactic procedures using the Wyko NT1100 INPE apparatus obtaining the Ra value. All the prophylactic methods caused an increase in the Ra value, with the bicarbonate group 4 having the best results in statistical analysis the tStudent test tool and there was no initial Ra variation among the 4 groups / Mestre
24

Estudo da aplicação de mínima quantidade de fluido no fresamento de acabamento da liga Ti-6Al-4V /

Garcia, Ubirajara. January 2015 (has links)
Orientador: Marcos Valério Ribeiro / Banca: José Vitor Candido de Souza / Banca: Manoel Cleber de Sampaio Alves / Banca: Rosemar Batista da Silva / Banca: João Roberto Ferreira / Resumo: Reduzir o uso de fluidos de corte em operações de usinagem é uma meta que tem sido buscada na indústria devido aos problemas ecológicos e de saúde humana, causados pelos fluidos de corte. No entanto, os fluidos de corte ainda promovem uma vida de ferramenta mais longa para muitas operações de usinagem. Este é o caso da operação de fresamento de acabamento da liga de titânio Ti6Al4V usando pastilhas de metal duro recobertas. Portanto, o objetivo deste trabalho é estudar condições de corte mais adequadas para o uso da técnica de mínima quantidade de fluido, ou seja, condições que tornem a vida da ferramenta na técnica MQF, mais próximas ou superiores àquelas obtidas com corte sem lubri-refrigeração e corte com jorro de fluido, sem prejudicar a rugosidade da peça. Para alcançar estes objetivos vários experimentos de fresamento de acabamento foram realizados, variando-se a velocidade de corte e taxa de avanço com aplicação da técnica MQF com o uso de três diferentes fluidos comparados com o corte sem lubri-refrigeração e corte com jorro de fluido. A principal conclusão deste estudo foi que a aplicação da técnica MQF no processo de fresamento de acabamento do Ti-6Al-4V aumenta a vida da ferramenta, melhorando a produtividade e rugosidade, quando mantidas as mesmas condições de corte originalmente propostas / Abstract: To reduce cutting fluids use in machining operations is one goal that has been searched in industrial companies, due to ecological and human health problems caused by the cutting fluid. However, the cutting fluids still provide a longer tool life for many machining operations. This is the case of Ti6Al4V titanium alloy end milling operation using coated carbide inserts. Therefore, this work objective is to study cutting conditions more suitable for minimum quantity of fluid technique use, i.e., conditions which make tool life in MQF technique, closer or over to that obtained with dry cutting and cutting with fluid fload, without damaging the workpiece roughness. To reach these goals several end milling experiments were carried out, varying up cutting speed and feed rate with MQF technique application with three different fluids compared with dry cutting and cutting with fluid fload. The main study conclusion was that applying the MQF technique in Ti-6Al-4V end milling process increases tool life, improving productivity and roughness, when kept up the same cutting conditions proposed originally / Doutor
25

Adesão bacteriana em braquetes metálicos com tratamento de superfície : estudo in vitro /

Tupinambá, Rogerio Amaral. January 2014 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Coorientador: Cristiane Aparecida de Assis Claro / Coorientador: Celestino José Prudente Nóbrega / Banca: Rosana Vilela Chagas / Banca: Cristiane Aparecida Pereira Correia / Resumo: A evolução dos acessórios utilizados em Ortodontia, especialmente no desenho e nos materiais empregados na confecção dos braquetes, tem apresentado grandes avanços tecnológicos. A presença dos aparelhos dentários aumenta a possibilidade de adesão bacteriana sobre estas superfícies e assim, o risco à cárie nos pacientes ortodônticos. Modificações na superfície dos braquetes, como o aumento da hidrofobicidade, redução da rugosidade superficial e deposição de filmes, tem sido empregadas como opção para redução da adesão bacteriana. Neste estudo in vitro, filmes de polímero de hexametildisiloxano foram depositados sobre braquetes metálicos convencionais e autoligantes, empregando a técnica PECVD (Deposição Química por Plasma de Rádio Frequência).As amostras foram divididas emquatrogrupos, dois com e dois sem tratamentode superfície. Foram avaliadas a variação da molhabilidade, rugosidade superficial e adesão de biofilme de Streptococos mutans.Os valores obtidos paraadesão de biofilmeforam analisados usando o teste de Kruskal-Wallis e SNK.Os resultados mostraram diferença estatística significante (p ≤0.05) entre os braquetes convencionais com e sem filme e, entre os braquetes convencionais e braquetes autoligantes. Portanto se conclui, que o tratamento de superfície foi efetivo na redução da adesão bacteriana nos braquetes convencionais, se observou também, que os braquetes convencionais apresentaram menor adesão de biofilme que os braquetes autoligantes / Abstract: The evolution of the accessories in Orthodontics,especially in the design and materials used in the brackets manufacture, has exhibited major technological advances.The presence of dental appliances increases the possibility of bacterial adhesionon these surfaces and thus the risk of caries in orthodontic patients. Changes on the brackets surface, asthe increased hydrophobicity, reduced surface roughness and film deposition have been employed asan option for reducing bacterial adhesion. In this in vitro study, hexamethyldisiloxane polymer films were deposited on conventional and self-ligating stainless steel brackets, using the Radio Frequency PECVD technique (Plasma- Enhanced Chemical Vapor Deposition). The samples were divided into four groups according to the surface treatment, two treated and two untreated. The changes in wettability, surface roughness and adhesion of the Streptococcus mutans biofilm were evaluated. The values obtained for biofilm adhesion were analyzed using the Kruskal-Wallis and SNK test. The results showed statistically significant difference (p ≤ 0.05)between conventional brackets before and after surface treatment and between conventional and self-ligating brackets. Therefore it was concluded that surface treatment was effective in reducing bacterial adhesion inconventional brackets, it was also noted that the conventional brackets showed lower biofilm adhesion than self-ligating brackets / Mestre
26

Resistência da linha de cola em superfícies lixadas da madeira de eucalipto /

Alves, Paulo Roberto Gomes. January 2012 (has links)
Orientador: Marcos Tadeu Tibúrcio Gonçalves / Coorientador: Manoel Cléber de Sampaio Alves / Banca: Marcos Valério Ribeiro / Banca: Ivaldo de Domenico Valarelli / Resumo: Este trabalho apresenta estudos de usinabilidade de peças de madeira de eucalipto, tendo por objetivo principal efetuar análises da resistência de juntas coladas em relação à qualidade das superfícies usinadas, a fim de se verificar a influência da rugosidade superficial sobre a adesão das superfícies coladas com adesivo à base de acetato de polivinila (PVA). Amostras da espécie de madeira Eucalyptus saligna foram preparadas para testes de resistência na lâmina de cola em ensaios de ruptura por cisalhamento e por tração normal segundo a norma NBR 7190. As superfícies de colagem foram preparadas por operação de fresamento empregando-se velocidade nominal de avanço de 11,0 m/min e posteriormente por operação de lixamento empregando-se cinco diferentes granulometrias de lixas, de granas: 80, 100, 120, 150 e 220. Depois de lixadas, as superfícies foram submetidas à medição da rugosidade com rugosímetro equipado com uma ponta apalpadora de diamante, de forma cone-esférica, com raio de ponta de 2µm, em conjunto com o programa de análise de superfícies. Dos resultados obtidos podem-se destacar os melhores desempenhos de resistência a ruptura; ao cisalhamento para superfícies lixadas por lixa de grana 220; à tração normal para superfícies lixadas por lixa de grana 120 / Abstract: This paper shows studies on machinability of eucalyptus wood battens; main goal is make analysis of resistance bonded joints in relation the quality of machined surface to determine the influence of surface roughness on the adhesion of the bonded surfaces adhesive-based polyvinyl acetate (PVA). Samples Eucalyptus saligna wood species were prepared for resistance testing in trials blade glue shear rupture and tensile normal according to NBR 7190. The bonding surfaces were prepared by milling operation employing feed speed of 11.0 m/min and then by the grinding operation using five different grain sizes of sandpaper (grands: 80, 100, 120, 150 and 220). After sanding, the surfaces were subjected to measurements of roughness with roughness equipped with a diamond probe tip of cone-spherical shape, with nose radius of 2µm, together with surface analysis program. Among the results we can point out the best performances of rupture strength, shear strength for sanded surfaces by sanding the bundles 220, the normal traction surfaces sanded by sanding to 120 cash / Mestre
27

Análise comparativa de ferramentas revestidas por PVD e CVD no torneamento do aço ABNT 8620 /

Costa, Anderson Figueiredo. January 2016 (has links)
Orientador: Marcos Valerio Ribeiro / Coorientador: João Paulo Barros Machado / Banca: Maneol Cleber de Sampaio Alves / Banca: João Roberto Ferreira / Resumo: Com o atual avanço de propriedades dos materiais, novas alternativas estão sendo buscadas para manufaturas desses materiais. Entre os processos, a usinagem se caracteriza por ser um processo que emprega milhões de pessoas. Entretanto para alcançar tais objetivos melhorias nas propriedades das ferramentas se faz necessária. Neste seguimento, os revestimentos vêm apresentando avanços significativos, como pode-se destacar o revestimento por CVD (deposição química a vapor) que permite que a ferramenta seja empregada nas temperaturas em torno de 1200ºC. Nesta mesma linha vale destacar o revestimento por PVD (deposição física a vapor) normalmente em uma única camada, o qual permite que a aresta de corte seja positiva, possa trabalhar com menor esforço de corte, e em temperatura aproximadamente em 700ºC. Este trabalho tem como objetivo analisar comparativamente o desempenho de ferramentas de metal duro revestidas pelo processo CVD e PVD no torneamento do aço ABNT 8620 sem uso de fluido de corte. Foram utilizadas duas pastilhas de metal duro revestidas pelo processo de PVD e CVD, com mesma geometria para efeito comparativo. A pastilha revestida por PVD tem espessura do revestimento de 3µm, enquanto que a pastilha revestida por CVD tem espessura do revestimento de 16µm. As pastilhas revestidas foram caracterizadas quanto a composição química dos elementos de revestimentos utilizando um microscópio eletrônico de varredura pela técnica de linescan e mapping. Posteriormente as ferramenta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With the current advancement of material properties, new alternatives are being sought for manufacturing these materials. Among the processes, machining is characterized as a process that employs millions of people. However to achieve such goals improvements in the tools properties is necessary. In this follow-up, the coatings have shown significant advances, as can highlight the coating by CVD (chemical vapor deposition) that allows the tool to be used at temperatures around 1200°C. In the same line it is worth highlighting the coating by PVD (physical vapor deposition) usually in a single layer, which allows the cutting edge is positive, can work with less shear stress, and temperature approximately 700°C. This study aims at comparing the performance of carbide tools coated by the CVD process and PVD in the steel turning ABNT 8620 without the use of cutting fluid. We used two carbide inserts coated by the PVD and CVD process, with the same geometry for comparison purposes. The tablet is coated by PVD coating thickness of 3μm, while the tablet is coated by CVD coating thickness of 16μm. The coated tablets were characterized as the chemical composition of coatings elements using a scanning electron microscope for linescan technique and mapping. Subsequently the tools were applied to turning the cutting speed (Vc) between 350 to 500 m/min, feed (f) 0.20 mm/rev and depth of cut (ap) of 1.00mm using a lathe ROMI mark, GL240M model. The characterizations were carried out using an optical microscope, scanning electron microscope and roughness. The results demonstrated that the tool coated by the CVD process has a better performance when compared to PVD this occurred because the tool coated by the CVD process has a multilayer coating having a higher heat input, supporting thus cutting temperatures ... (Complete abstract click electronic access below) / Mestre
28

Adesão bacteriana em braquetes metálicos com tratamento de superfície: estudo in vitro

Tupinambá, Rogerio Amaral [UNESP] 21 December 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-21Bitstream added on 2014-06-13T19:14:22Z : No. of bitstreams: 1 000734194.pdf: 8481046 bytes, checksum: 0d20d689a392b10b67c048f985b1dd09 (MD5) / A evolução dos acessórios utilizados em Ortodontia, especialmente no desenho e nos materiais empregados na confecção dos braquetes, tem apresentado grandes avanços tecnológicos. A presença dos aparelhos dentários aumenta a possibilidade de adesão bacteriana sobre estas superfícies e assim, o risco à cárie nos pacientes ortodônticos. Modificações na superfície dos braquetes, como o aumento da hidrofobicidade, redução da rugosidade superficial e deposição de filmes, tem sido empregadas como opção para redução da adesão bacteriana. Neste estudo in vitro, filmes de polímero de hexametildisiloxano foram depositados sobre braquetes metálicos convencionais e autoligantes, empregando a técnica PECVD (Deposição Química por Plasma de Rádio Frequência).As amostras foram divididas emquatrogrupos, dois com e dois sem tratamentode superfície. Foram avaliadas a variação da molhabilidade, rugosidade superficial e adesão de biofilme de Streptococos mutans.Os valores obtidos paraadesão de biofilmeforam analisados usando o teste de Kruskal-Wallis e SNK.Os resultados mostraram diferença estatística significante (p ≤0.05) entre os braquetes convencionais com e sem filme e, entre os braquetes convencionais e braquetes autoligantes. Portanto se conclui, que o tratamento de superfície foi efetivo na redução da adesão bacteriana nos braquetes convencionais, se observou também, que os braquetes convencionais apresentaram menor adesão de biofilme que os braquetes autoligantes / The evolution of the accessories in Orthodontics,especially in the design and materials used in the brackets manufacture, has exhibited major technological advances.The presence of dental appliances increases the possibility of bacterial adhesionon these surfaces and thus the risk of caries in orthodontic patients. Changes on the brackets surface, asthe increased hydrophobicity, reduced surface roughness and film deposition have been employed asan option for reducing bacterial adhesion. In this in vitro study, hexamethyldisiloxane polymer films were deposited on conventional and self-ligating stainless steel brackets, using the Radio Frequency PECVD technique (Plasma- Enhanced Chemical Vapor Deposition). The samples were divided into four groups according to the surface treatment, two treated and two untreated. The changes in wettability, surface roughness and adhesion of the Streptococcus mutans biofilm were evaluated. The values obtained for biofilm adhesion were analyzed using the Kruskal-Wallis and SNK test. The results showed statistically significant difference (p ≤ 0.05)between conventional brackets before and after surface treatment and between conventional and self-ligating brackets. Therefore it was concluded that surface treatment was effective in reducing bacterial adhesion inconventional brackets, it was also noted that the conventional brackets showed lower biofilm adhesion than self-ligating brackets
29

Resistência da linha de cola em superfícies lixadas da madeira de eucalipto

Alves, Paulo Roberto Gomes [UNESP] 15 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-15Bitstream added on 2014-06-13T19:14:24Z : No. of bitstreams: 1 alves_prg_me_guara.pdf: 1144534 bytes, checksum: c564c6fdb34127fdaaba0cd2ec9f184d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta estudos de usinabilidade de peças de madeira de eucalipto, tendo por objetivo principal efetuar análises da resistência de juntas coladas em relação à qualidade das superfícies usinadas, a fim de se verificar a influência da rugosidade superficial sobre a adesão das superfícies coladas com adesivo à base de acetato de polivinila (PVA). Amostras da espécie de madeira Eucalyptus saligna foram preparadas para testes de resistência na lâmina de cola em ensaios de ruptura por cisalhamento e por tração normal segundo a norma NBR 7190. As superfícies de colagem foram preparadas por operação de fresamento empregando-se velocidade nominal de avanço de 11,0 m/min e posteriormente por operação de lixamento empregando-se cinco diferentes granulometrias de lixas, de granas: 80, 100, 120, 150 e 220. Depois de lixadas, as superfícies foram submetidas à medição da rugosidade com rugosímetro equipado com uma ponta apalpadora de diamante, de forma cone-esférica, com raio de ponta de 2µm, em conjunto com o programa de análise de superfícies. Dos resultados obtidos podem-se destacar os melhores desempenhos de resistência a ruptura; ao cisalhamento para superfícies lixadas por lixa de grana 220; à tração normal para superfícies lixadas por lixa de grana 120 / This paper shows studies on machinability of eucalyptus wood battens; main goal is make analysis of resistance bonded joints in relation the quality of machined surface to determine the influence of surface roughness on the adhesion of the bonded surfaces adhesive-based polyvinyl acetate (PVA). Samples Eucalyptus saligna wood species were prepared for resistance testing in trials blade glue shear rupture and tensile normal according to NBR 7190. The bonding surfaces were prepared by milling operation employing feed speed of 11.0 m/min and then by the grinding operation using five different grain sizes of sandpaper (grands: 80, 100, 120, 150 and 220). After sanding, the surfaces were subjected to measurements of roughness with roughness equipped with a diamond probe tip of cone-spherical shape, with nose radius of 2µm, together with surface analysis program. Among the results we can point out the best performances of rupture strength, shear strength for sanded surfaces by sanding the bundles 220, the normal traction surfaces sanded by sanding to 120 cash
30

Avaliação da rugosidade superficial de restaurações estéticas e do esmalte adjacente após o uso de diferentes instrumentos rotatórios de acabamento e polimento /

Silva, Regina Célia Santos Pinto. January 1997 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Maria Salete Machado Cândido / Banca: Rubens Corte Real de Carvalho / Banca: Marco Antonio Bottino / Banca: Newton José Giachetti / Resumo: O propósito do presente trabalho foi avaliar in vitro a rugosidade superficial de dois materiais restauradores estéticos, resina composta TPH (Dentsply) e compósito poliácido modificado VariGlass (Dentsply) e também do esmalte adjacente a estas restaurações, após procedimentos de acabamento com ponta diamantada e brocas multilaminadas de oito e 12 lâminas e polimento com ponta verde de silicone, pasta diamantada e a associação das duas. Foram selecionados 114 dentes sendo que seis deles foram deixados intatos para se avaliar a rugosidade do esmalte sem nenhum tipo de tratamento e os demais receberam preparos cavitários no terço médio da face vestibular, sendo restaurados conforme instruções do fabricante. Os corpos de prova foram armazenados em água destilada, em estufa a 370, por 24 horas, após o que receberam acabamento e polimento. Após estes procedimentos os corpos de prova foram analisados num rugosímetro Perthometer S8P (Perthen, Mahr, Germany) e os dados obtidos foram analisados estatisticamente. De acordo com os resultados pudemos verificar que a resina composta apresenta menor rugosidade que o cimento de ionômero vítreo; que o esmalte adjacente às restaurações tomou-se mais liso que o esmalte íntegro: as brocas multilaminadas mostraram menores valores de rugosidade quando comparadas às pontas diamantadas, com diferença estatisticamente significante; nenhum dos procedimentos de acabamento e polimento empregados foi satisfatório para o cimento de ionômero vítreo, que apresentou os maiores valores de rugosidade média e são necessárias novas investigações sobre acabamento e polimento desses materiais, assim como pesquisas sobre o próprio material para que possamos vir a ter restaurações com melhor qualidade de superfície / Abstract: The purpose of this "in vitro" study was to evaluate the surface texture of two aesthetic restorative materials: a composite resin TPH (Dentsply) and a polyacid-modified composite VariGlass (Dentsply). as well as the adjacent enamel to these restorations, after polishing and finishing procedures with diamond points, with eight and twelve blade trimming and finishing burs, with a green silicone tip, with a diamond polishing past and with an association of the last two procedures. We have selected 114 teeth, six of wich received neither polishing nor finishing procedures, with the purpose of evaluating the enamel roughness. The remaining teeth received cavity preparations on the buccal surfaces and were restored following the manufacture' s instructions. The specimens were kept for 24 hours in destiled water at 37° C and only then polishing and finishing procedures were performed. Profilometric analyses were carried out using a Perthometer S8P (Perthen, Mahr, Germany) and the collected data were statísticaly analysed. The results showed that the composite resin presented less surface roughness than the polyacid-modified composite, that the enamel adjacent to the restorations became smoother than the sound enamel; that the eight and twelve blade burs promoted surfaces less roughen than the diamond points, with statisticaly meaningful difference. None of the finishing and polishing procedures demonstrated to be satisfactory for the glass ionomer cement. Researches concerning the finishing and polishing of this material are necessary, as well as the material itself: so that better surface texture restorations could be obtained / Doutor

Page generated in 0.1266 seconds