• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utveckling av beräkningsmodell för värmepumpstillsats i avfuktarsystem

Björklund, Markus January 2018 (has links)
One way to make a dehumidifier system more energy efficient is to attach a heat pump onto the dehumidifier. In this master thesis, a MATLAB-based computational model is developed to simulate the heat pump application. The aim for this model is to optimize various configurations of the heat pump, and to be used as a tool in theproduct development process. The computational model should also verify the measurements that have been made on the prototype for the heat pump application. The heat pump application is mathematically described by a set of equations. Together with a set of unknown model parameters, this creates an equation system. Theequation system is then solved numerically with Newton's method in multiple variables. The validation of the calculation model shows relatively small model errors between simulated and measured data. The exception is the model error of the condensing temperature of the refrigerant, where the model error is more than twice as big as the error in other simulated temperatures. This may be due to extrapolating of curve fitted data in order to calculate the total efficiency of the compressor. Another method to calculate the total efficiency of the compressor should therefore be considered in order to reduce the model error of the condensing temperature of the refrigerant. Simulations of the model also show that choosing the refrigerant R134a over R1234yf increases the heat pump coefficient of performance (COP) by an average of 12 %. The results have also shown that heat exchangers with 3 tube rows instead of 2 gives the heat pump an increased COP. This result could be utilized tocompensate for the reduced COP when R1234yf is the refrigerant of choice.
2

Inomhusklimat i ett statligt byggnadsminne / Indoor climate in historic buildings

Wängdahl, Terese January 2013 (has links)
Statliga byggnadsminnen är byggnader som genom dess speciella kulturhistoriska värde är extra viktiga att bevara för framtiden. Att bevara, speciellt äldre byggnader, är inte alltid helt enkelt. En av utmaningarna i detta är att hålla ett lämpligt inomhusklimat i byggnaden för att förhindra en allt för snabb nedbrytningsprocess av material. Det finns tre lämpliga metoder för styrning av inomhusklimatet; Skyddsvärme, avfuktning samt styrd ventilation. Beroende på vad den byggnad eller det rum som studeras skall användas till och hur de unika förutsättningarna ser ut just där kan olika metoder vara olika lämpliga. Studieobjektet i den här rapporten är Salsta slott, här har fyra rum studerats för att avgöra vilken metod som skulle kunna passa i respektive rum. Rummen har aningen olika förutsättningar och behov vilket ger en bra grund till att kunna se hur de skiljer sig vad det gäller lämpliga metoder.
3

Klimatförhållanden och energianvändning på Gränby ishall : Hur Uppsala kommun Arenor och fastigheter AB kan förbättra klimatförhållandena och sänka energianvändningen i Gränby ishall

Kylhed, Ebba January 2024 (has links)
This report intends to investigate climate conditions and energy consumption in Gränby Ice rink in Uppsala.Today, Gränbyhallen faces a potential renovation project to modernize and improve what was initially intended as a temporary hall that was inaugurated in 1974.In 2021, the property was taken over by the Uppsala municipality Arenor och Fastigheter AB from having previously been owned by the municipality. Since then, Arenor och Fastigheter has worked to modernize its facilities and in this way also work to improve the energy consumption required by the operation of the Gränby ice rink and also examine the indoor climate conditions in the building.The idea is to make the climate more pleasant for the visitors, and therefore making it less cold and barren temperaturevise by separating the ventilation from the ice and bleachers so that these can be controlled individually. The hope is to be able to reduce energy consumption with such a solution by seeing if the facility has heat leakage from the outside and how moisture can be managed in the facility to be kept at a more even level throughout the year and during the day.For the report, weather data was obtained from SMHI and then compiled and compared with temperatures and energy consumption from sorption dehumidifiers and the plant total to locate current deficiencies but also how to potentially address these to lower energy consumption.Analysis of the data was also done for the outdoor temperature which was set against the indoor temperature and then also the difference between the two to see the difference anddemonstrate how well insulated the facility is. On average over the entire time investigated, there was only +1°C difference between outside and inside, which gives an indication that the insulation in the facility needs to be reviewed and improved both outside and inside as there are large leaks in the facility with open surfaces and only metal doors that separate warm surfaces from cold.The analysis also suggests that the dehumidifier should be changed to regulate according to the dew point temperature from regulating according to the relative humidity as the dew point changes less over time and is less affected by the amount of water in the air which changes from hour to hour and is also affected by the outdoor climate when doors are opened and closed to the facility. / Denna rapport avser att undersöka klimatförhållanden och energiförbrukningen i Gränby ishall i Uppsala. Idag står Gränbyhallen inför ett potentiellt renoveringsarbete för att modernisera och förbättra till en som till en början var tänkt som en provisorisk hall från 1974. 2021 togs fastigheten över av Uppsala kommun Arenor och Fastigheter AB från att tidigare varit kommunägt. Arenor och Fastigheter har sedan dess arbetat med att modernisera sina fastigheter och på så sätt även arbeta med att förbättra energiförbrukningen som driften i Gränby ishall kräver och även undersöka klimatförhållandena inomhus. Tanken är att göra klimatet för åskådarna mer behagligt att vistas i från dagens kalla och karga temperaturer genom att separera läktarens ventilation och avfuktning från isens, så att dessa kan styras enskilt och därmed ha olika klimat. Förhoppningen är att med en sådan lösning kunna minska energiförbrukningen genom att se ifall anläggningen har värmeläckage från utsidan samt hur fukt kan hanteras i anläggningen för att hållas på en mer jämn nivå över året och under dagen. Till rapporten har väderdata hämtats från SMHI och sedan sammanställts och jämförts med temperaturer och energiförbrukning från sorptionsavfuktare och anläggningens total för att lokalisera nuvarande brister, men även hur man kan potentiellt åtgärda dessa för att sänka energiförbrukningen. Analys av data gjordes även för temperaturen utomhus mot temperaturen inomhus och då differensen av de två för att se skillnaden och påvisa även hur väl isolerad anläggningen är. I genomsnitt över hela tiden som undersöktes skildes det bara +1°C mellan ute och inne, vilket ger indikation på att isoleringen i anläggningen behöver ses över och förbättras både ute och inne då det finns stora läckage i anläggningen med öppna ytor och endast plåtdörrar som separerar varma ytor från kalla. Analysen tyder även på att avfuktaren bör ändras till att reglera efter daggpunktstemperaturen i stället för som nu efter relativa luftfuktigheten. Daggpunkten ändras mindre över tid och påverkas mindre av luftens vattenmängd, som ändras från timme till timme och som påverkas även av utomhusklimatet när dörrar öppnas och stängs till anläggningen.

Page generated in 0.0307 seconds