• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1209
  • 44
  • 40
  • 39
  • 34
  • 27
  • 16
  • 12
  • 8
  • 8
  • 7
  • 5
  • 3
  • 1
  • 1
  • Tagged with
  • 1250
  • 648
  • 110
  • 102
  • 101
  • 101
  • 100
  • 92
  • 91
  • 86
  • 85
  • 76
  • 73
  • 73
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Análise cinemática do salto vertical fora e dentro da água / Giullia Paula Rinaldi ; orientadora, Vera Lúcia Israel ; co-orientador, Elisangela Ferretti Manffra

Rinaldi, Giullia Paula January 2007 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2007 / Bibliografia: f. 71-78 / O ambiente aquático tem assumido um papel importante nas atividades de reabilitação e treinamento desportivo, mesmo em esportes não aquáticos. Uma das razões para isso é que as propriedades da água reduzem o risco de lesões durante atividades de impacto, / The aquatic environment has played an important role in rehabilitation and sportive training even for non aquatic sports. One reason for this is that water properties reduce the injury risk during impact activities, such as jumping. On the other hand, the
362

Estudo comparativo dos parâmetros cinemáticos angulares e lineares da marcha humana em ambiente aquático e terrestre em indivíduos hígidos adultos jovens / Danieli Isabel Romanovitch Ribas ; orientadora, Vera Lúcia Israel ; co-orientadora, Elisângela Ferretti Manffra

Ribas, Danieli Isabel Romanovitch January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / Há um grande interesse em estudar o movimento humano dentro da água, uma vez que o meio já é utilizado para treinamento esportivo e nos processos de recuperação funcional devido às diferentes propriedades mecânicas e térmicas que oferece. No entanto, há u
363

Análise do impacto da artrodese cervical anterior nos níveis adjacentes à fusão / Vivian Domit Pasqualin ; orientador, Luiz Roberto Aguiar ; co-orientador, Munir Antônio Gariba

Pasqualin, Vivian Domit January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: p. 74-81 / A abordagem cirúrgica da coluna cervical por via anterior ganhou popularidade por sua utilização nas mais variadas formas de desordem da coluna cervical. Os resulta-dos em grupos de pacientes operados não fumantes, com um ou dois níveis de fu-são, atingem / The anterior surgical approach to the cervical spine gained popularity due to its large applicability to the cervical spine disorders. The results in the non smoke operated patient groups, with one or two fusion levels, reached 95% of success. It is conse
364

Utilização de câmeras de ação para análise cinemática tridimensional do movimento humano / The use of action sport cameras for three- dimensional kinematic analysis of human movement

Bernardina, Gustavo Ramos Dalla 25 October 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-04-10T13:52:44Z No. of bitstreams: 1 texto completo.pdf: 7335609 bytes, checksum: 36caabaacd5a9c49963fb66e529252aa (MD5) / Made available in DSpace on 2017-04-10T13:52:44Z (GMT). No. of bitstreams: 1 texto completo.pdf: 7335609 bytes, checksum: 36caabaacd5a9c49963fb66e529252aa (MD5) Previous issue date: 2016-10-25 / Câmeras de ação (ASC - Action Sport Camera) são principalmente utilizadas para fins recreativos. Porém contínuas melhorias técnicas, em correspondência a uma redução de custo, cria a possibilidade de seu uso em análises tridimensionais (3D) de movimentos, como no estudo de gestos esportivos e na avaliação quantitativa do desempenho atlético. Nesse contexto, o objetivo geral dessa dissertação foi avaliar a utilização de câmeras de ação (ASC – Action Sport Camera) para a análise cinemática tridimensional. No primeiro estudo o objetivo foi avaliar o efeito de diferentes estratégias de aquisição no protocolo de calibração das ASC e como isso afeta a exatidão tridimensional. Duas GoPro Hero3+ Black (frequência: 60Hz; resolução de imagem: 1280×720 / 1920×1080 pixels) foram posicionadas dentro da água em uma piscina, abrangendo um volume de trabalho de aproximadamente 6m 3 . Foi implementado um procedimento específico de calibração com duas etapas, que consiste na aquisição de um triedro estático e de um bastão em movimento, com nove e um marcadores esféricos passivos, respectivamente. Após avaliar os parâmetros da câmera, foram adquiridas várias posições de uma barra rígida, contendo dois marcadores de distância conhecida, dentro do volume de trabalho. O erro médio da reconstrução sobre a distância inter-marcadores foi inferior a 2,5mm (1280×720) e 1,5mm (1920×1080). Os resultados deste estudo demonstram que a calibração subaquática de ASC é viável, permitindo medições cinemáticas quantitativas com exatidão comparável aos sistemas tradicionais de captura de movimento. No segundo estudo o objetivo foi avaliar a exatidão e reconstrução tridimensional a partir das configurações de aquisição permitida pelas câmeras (diferentes resoluções de imagem, ângulos de visão e frequências de aquisição) em movimentos dentro (piscina) e fora (laboratório) da água. A fim de calibrar o par de câmeras, marcadores esféricos pretos foram colocados em duas ferramentas de calibração, utilizadas tanto dentro quanto fora da água, e uma otimização não-linear de duas etapas foi realizada. A exatidão na reconstrução 3D dos marcadores e a reprodutibilidade ao estimar os parâmetros das câmeras representaram o desempenho do sistema. Para ambos ambientes (laboratório e subaquático), os testes estatísticos foram focados na comparação de diferentes configurações das câmeras. Em seguida, cada configuração foi comparada para os dois ambientes. E foi demonstrada uma aplicabilidade de obtenção de variáveis cinemáticas dentro da água. Em todas as resoluções avaliadas, e em ambos ambientes (laboratório e subaquático), o erro de reconstrução foi inferior a 3mm e o erro relacionado ao volume de trabalho diagonal variou de 1: 2000 (3×1,3×1,5 m 3 ) a 1:7000 (4,5×2,2×1,5 m 3 ) em concordância com a literatura. Estatisticamente, a exatidão 3D obtida em laboratório foi inferior (p<10 -5 ) à subaquática, em todas as configurações de câmera testadas. Em relação à reprodutibilidade dos parâmetros das câmeras, foi encontrada uma baixa variabilidade nos dois ambientes (1.7% e 2.9%, laboratório e subaquático). Na avaliação cinemática do nado foi possível reconstruir a trajetória submersa do nado crawl. Foi identificada uma manutenção do padrão de braçada durante todo o nado e uma técnica comparada ao modelo proposto na literatura. Esses resultados apoiam o uso da tecnologia das ASC para realizar reconstruções quantitativas tanto em laboratório quanto em ambiente subaquático. No terceiro estudo o objetivo foi avaliar, em condição de laboratório, a precisão, exatidão e dados cinemáticos das câmeras ASC e comparar a um sistema comercial de análise de movimento 3D. Quatro câmeras GoPro Hero3+ Black (frequência: 120Hz; resolução de imagem: 1280×720 pixels) e quatro câmeras ViconMX40 (frequência: 120Hz; resolução de imagem: 2353×1728 pixels) foram utilizadas para comparação. Para calibração das câmeras foram utilizadas as ferramentas e o procedimento recomendado pela Vicon (Oxford Metrics Ltd., UK). O desempenho do sistema foi representado pela precisão e exatidão na reconstrução 3D dos marcadores e pela aquisição de dados cinemáticos da marcha e salto. Apesar de ser encontradas altas correlações (r=0,99) e desvios (bias) inferiores a 3mm, os dois sistemas apresentaram uma diferença sistemática confirmada pelo viés estatisticamente significativo. Em relação à exatidão foi encontrada uma diferença entre os dois sistemas, com um erro de 8 a 10 vezes maior para as câmeras ASC. Apesar desses resultados, não foram encontradas diferenças entre os dados cinemáticos. Isso sugere que, apesar do sistema comercial Vicon alcançar melhor desempenho que o sistema com câmeras ASC, como era esperado, em termos práticos, as diferenças não foram significativas para a obtenção de parâmetros cinemáticos. O objetivo principal de um sistema é a análise de movimentos e, desta forma, a ASC se mostrou viável na avaliação da cinemática 3D de movimentos humanos. No quarto estudo o objetivo foi avaliar os parâmetros de exatidão da reconstrução tridimensional e dados cinemáticos fornecidos por câmeras optoeletrônicas e câmeras de ação, colocadas em movimento. Experimentalmente as câmeras foram fixadas em uma estrutura rígida móvel (4,4×4×2,5m 3 ) e os dados foram adquiridos simultaneamente pelos dois tipos de câmeras. Foram realizadas aquisições de um teste de barra rígida e da marcha humana para avaliar a exatidão da reconstrução 3D e calcular as variáveis lineares e angulares da marcha. Algoritmos foram desenvolvidos para fazer a translação do sistema de coordenadas global a partir de pontos de referência dispostos no chão de um corredor de 40 metros, conforme as câmeras e a estrutura se movimentavam. Como resultado preliminar, é importante ressaltar que o erro percentual encontrado (1%) pelas câmeras ASC é comparável ao erro encontrado em aquisições com o sistema estático, como visto no artigo 3 dessa dissertação. Em relação aos dados cinemáticos destaca-se a captura de aproximadamente 18 ciclos de passada em uma única aquisição, fato importante a ser considerado para se definir um padrão de movimento. Além disso, os dois sistemas de avaliação cinemática encontraram valores próximos para as variáveis analisadas. O artigo ainda está em fase de finalização, no entanto sugere que, ao avaliar movimentos em deslocamento horizontal de aproximadamente 40 metros, é viável utilizar ASC para reconstruir tridimensionalmente uma marcha natural, não delimitada à laboratório. Em conclusão, essa dissertação sugere que as ASC são viáveis para avaliar tridimensionalmente movimentos humanos. / Action sport camera (ASC) are used mainly for recreational purposes but their continuous technical improvements, in correspondence of cost decreases, creates the possibility of to use in three-dimensional (3D) motion analysis, as in sports gestures study and athletic performance evaluation quantitatively. In this context, the main purpose of this thesis was to evaluate the usage of the action sport camera (ASC) for three-dimensional (3D) kinematic analysis. In the first study the aim was to evaluate the effect of different acquisition strategies on the calibration protocol of the ASC and how this affects the three-dimensional accuracy. Two GoPro Hero3+ Black (frequency: 60Hz; image resolutions: 1280×720/1920×1080 pixels) were located underwater into a swimming pool, surveying a working volume of about 6m 3 . A two-step custom calibration procedure, consisting in the acquisition of one static triad and one moving wand, carrying nine and one spherical passive markers, respectively, was implemented. After assessing camera parameters, a rigid bar, carrying two markers at known distance, was acquired in several positions within the working volume. The average error upon the reconstructed inter-marker distances was less than 2.5mm (1280×720) and 1.5mm (1920×1080). The results of this study demonstrate that the calibration of underwater ASC is feasible enabling quantitative kinematic measurements with accuracy comparable to traditional motion capture systems. In the second study the aim was to evaluate the reconstruction accuracy three-dimensional from the acquisition configurations allowed by the cameras (different image resolutions, fields of view and acquisition frequencies) in in-air (laboratory) and underwater (swimming pool) movements. In order to calibrate the camera stereo pair, black spherical markers placed on two calibration tools, used both in-air and underwater, and a two-step nonlinear optimization were exploited. The 3D reconstruction accuracy of testing markers and the repeatability of the estimated camera parameters accounted for system performance. For both environments, statistical tests were focused on the comparison of the different camera configurations. Then, each camera configuration was compared across the two environments. And it was demonstrated an applicability of obtaining underwater kinematic variables. In all assessed resolutions, and in both environments, the reconstruction error (true distance between the two testing markers) was less than 3mm and the error related to the working volume diagonal was in the range of 1:2000 (3×1.3×1.5m 3 ) to 1:7000 3 (4.5×2.2×1.5m ) in agreement with the literature. Statistically, the 3D accuracy obtained in the in-air environment was poorer (p<10 -5 ) than the one in the underwater environment, across all the tested camera configurations. Related to the repeatability of the camera parameters, we found a very low variability in both environments (1.7% and 2.9%, in-air and underwater). In the swimming kinematic evaluation it was possible to reconstruct the underwater trajectory of the freestyle. A stroke standard maintenance was identified throughout the swim and a technique compared to the model proposed in the literature. This result encourage the use of ASC technology to perform quantitative reconstruction both in-air and underwater environments. In the third study the aim was to evaluate, in laboratory condition, the precision, accuracy and kinematic data of the ASC cameras and to compare to a commercial system of 3D motion analysis. Four GoPro Hero3+ Black cameras (frequency: 120Hz, image resolution: 1280×720 pixels) and four ViconMX40 cameras (frequency: 120Hz, image resolution: 2353×1728 pixels) were compared. For the camera calibration, the tools and the procedure recommended by Vicon (Oxford Metrics Ltd., UK) were used. The system performance was represented by the precision and accuracy in the 3D reconstruction of the markers and by the acquisition of the gait and jump kinematic data. Although high correlations (r = 0.99) and deviations (bias) of less than 3 mm were found, both systems showed a systematic difference confirmed by the bias statistically significant. Regarding accuracy, a difference between the two systems was found with an error of 8 to 10 times higher for the ASC cameras. Despite these results, no differences were found between the kinematic data. This suggests that although the commercial system Vicon has obtained better performance than the system with ASC camera, as was expected, in practical terms, the differences were not significant for obtaining kinematic parameters. The main objective of a system is the motion analysis and, in this way, the ASC proved to be feasible in the evaluation of the 3D kinematics of the human movements. In the fourth study the aim was to evaluate the accuracy parameters of the 3D reconstruction and the kinematic data provided by optoelectronic cameras and ASC cameras, set in motion. Experimentally the cameras were fixed in a rolling rigid structure (4.4×4×2.5m 3 ) and the data were acquired simultaneously by the two types of cameras. A rigid bar test and human gait were acquired to evaluate the 3D reconstruction accuracy and to calculate the gait linear and angular variables. Algorithms were developed to do the translation of the global coordinate system from reference points arranged on the floor of a 40 meter track runner, according as the cameras and the structure were moving. As a preliminary result, it is important to highlight that the percentage error found (1%) by ASC cameras is comparable to the error found in acquisitions with the static system, as seen in the article 3 of this dissertation. Regarding the kinematic data, it is noteworthy the capture of approximately 18 stride cycles in a single acquisition, an important fact to be considered in order to define a movement pattern. In addition, the two kinematic evaluation systems found close values for the variables analyzed. The article is still being finalized, however, it suggests that when evaluating movements in horizontal displacement of approximately 40 meters, it is feasible to use ASC to reconstruct three-dimensionally a natural gait, not delimited to the laboratory. In conclusion, this dissertation suggests that the ASC are feasible to evaluate human movements three-dimensionally.
365

Aspectos físicos, químicos e mecânicos de tíbias de frangos de corte / Physical, chemical and mechanical aspects of broilers tibial bones

Reis, Denise Torres da Cruz 21 February 2005 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-10-06T13:41:03Z No. of bitstreams: 1 texto completo.pdf: 1885900 bytes, checksum: 8726b1095eee8fb9ac9dda8ea8597418 (MD5) / Made available in DSpace on 2016-10-06T13:41:03Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1885900 bytes, checksum: 8726b1095eee8fb9ac9dda8ea8597418 (MD5) Previous issue date: 2005-02-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Foi realizado um experimento com o objetivo de determinar aspectos físicos, químicos e mecânicos das tíbias de frangos de corte. Foram avaliados o peso vivo das aves e peso, comprimento, densidade, porosidade, teores de cinzas e minerais das tíbias. Também foram estudadas a área da seção transversal, momento de inércia, carga máxima na flexão, resistência à flexão, rigidez e tenacidade dos referidos ossos. Os dados foram coletados no período de 21 a 42 dias de idade. Foram utilizados 600 pintos de um dia de idade, machos e fêmeas, oriundos de três cruzamentos, dois da Universidade Federal de Viçosa (UFV) e um comercial, alojados em boxes de piso de cimento cobertos com cepilho de maravalha. Todos receberam as mesmas rações, inicial (1 a 21 dias), crescimento (22 a 35 dias) e final (36 a 42 dias), calculadas para atender as exigências nutricionais das aves em cada período. Foi utilizado delineamento experimental inteiramente casualizado em esquema fatorial 3 x 2 (três cruzamentos e os dois sexos), cinco repetições e 10 aves por unidade experimental (boxe). Semanalmente, aos 21, 28, 35 e 42 dias de idade, foram amostrados aleatoriamente um macho e uma fêmea por boxe, num total de 5 boxes por cruzamento, sendo que a cada idade os boxes amostrados não se repetiam. O cruzamento comercial apresentou taxa de crescimento superior aos cruzamentos da UFV, causando respostas adaptativas das tíbias, que alteraram, principalmente, aspectos relacionados à sua geometria. Apesar do maior peso das aves, a resistência óssea do cruzamento comercial não foi superior à dos demais. Desta forma, a continuidade do processo de melhoramento para ganho de peso pode resultar no aumento da ocorrência de problemas estruturais. Um dos cruzamentos da UFV (C1), além de apresentar pior desempenho no crescimento, apresentou ossos menos densos e menos resistentes aos 42 dias de idade, o que pode aumentar o risco de deformações e fraturas e, em conjunto, o torna menos interessante economicamente. Entre os sexos, as fêmeas, por apresentarem taxa de crescimento inferior aos machos (dimorfismo sexual), tenderam a desenvolver ossos de melhor qualidade, ou seja, mais densos, mais rígidos e mais resistentes, o que explica, em parte, porque a incidência de deformidades ósseas é menor neste sexo. / An experiment was carried out focused in the physical, chemical and mechanical aspects of broilers tibial bones. The main variables involved were: body weight and tibial weight, length, density, porosity, ash and mineral content. Also, cross-sectional area, moment of inertia, maximum load, strength, stiffness and toughness in bending of the bones were studied. The experimental period comprised the broilers growing fase (21 to 42 days). Six hundred day-old broilers, male and female, from three different lines, one comercial and two developed at Federal University of Viçosa (UFV), were reared in wood shaving covered floor. They were fed the starter (1 to 21 days), grower (22 to 35 days) and finisher (36 to 42 days) diets, designed to satisfy their nutritional requirements in each phase. The experiment design was completely randomized, in a factorial arrengement of treatments (three lines and two sexes) with 5 replicates and 10 birds per experimental unit. The comercial line grew at a faster rate than the UFV lines, resulting in bones adaptations by altering their morphological aspects. Although they had higher weights, their bones were not stronger than those from the other lines. Then, the ongoing process of selecting this line for body weight gain may result in a increasing occurrence of leg abnormalities and structural problems. One of the UFV lines presented the lowest growth performance, also developing less dense and less strong bones, rising the risk of deformities and fracture occurrence. Thus, with these features, this line seems to be of little comercial interest. Considering sexual differences, as the females grew at lower rates (sexual dimorfism), they tended to develop bones with better quality, which means denser, stiffer and stronger. These aspects, partially explain why females are less susceptible to bone deformities than males. / Dissertação importada do Alexandria
366

Os efeitos de três diferentes protocolos de treinamento isocinético nas adaptacões neuromusculares de flexores e extensores do joelho

Ruas, Cassio Victora January 2016 (has links)
O treinamento isocinético é uma alternativa eficaz para incrementos neuromusculares e na performance de torque muscular dos flexores e extensores do joelho. No entanto, o treinamento mais efetivo para aumentar o equilíbrio de torque muscular entre isquiotibiais e quadríceps (I/Q) ainda parece desconhecido. Portanto, o objetivo deste estudo foi comparar os efeitos de três diferentes tipos de treinamentos isocinéticos nas razões I/Q convencional (Rcon) e funcional (Rfun). Adicionalmente, foram avaliados os efeitos desses treinamentos nas variáveis de pico de torque (PT) concêntrico e excêntrico, pico de torque isométrico (PTI) taxa de produção de torque (TPT), ativação muscular (EMG), atraso eletromecânico (AE), espessura muscular (EM) e echo-intensity (EI) dos músculos flexores e extensores do joelho, bem como no desempenho funcional através dos testes squat jump (SJ), counter movement jump (CMJ), drop jump (DJ) e sprint 40m. Quarenta sujeitos homens destreinados (22,87 ± 2,28 anos, 70,66 ± 11,04 kg, 174,29 ± 6,9 cm) realizaram 6 semanas de treinamento para flexores e extensores do joelho em um dinamômetro isocinético Biodex. Eles foram selecionados de forma randomizada em 3 grupos de treinamento: modo concêntrico de extensão e concêntrico de flexão de joelhos (CON/CON); modo excêntrico de extensão e excêntrico de flexão de joelhos (EXC/EXC); modo concêntrico de extensão e excêntrico de flexão de joelhos (CON/EXC); e um grupo controle que não realizou nenhum treinamento (CNTRL). Todas as sessões de treinamento foram separadas por pelo menos 48h e as variáveis analisadas foram testadas em 2 dias, sendo realizadas 72h antes e depois da realização dos treinamentos. O grupo que treinou no modo EXC/EXC obteve maiores resultados na RFun, assim como aumentos significativos em PT excêntrico, PTI, CMJ e DJ comparado aos demais grupos (p<0,05), enquanto o grupo que treinou no modo CON/CON aumentou TPF em relação aos demais (p>0.05). Todos os grupos aumentaram EM do quadríceps e isquiotibiais de forma similar (p<0,05). Não houve diferença entre os grupos para PT concêntrico, EMG, AE, EI, RCon, SJ ou Sprint 40m (p>0,05). Portanto, o modo de treinamento EXC/EXC pode ser o mais efetivo para aumentar equilíbrio de torque muscular funcional I/Q. Treinamento excêntrico aumenta o torque excêntrico, influenciando nos aumentos na RFun e em saltos verticais que envolvem torque excêntrico (CMJ e DJ). O modo de treinamento CON/CON pode ser o mais efetivo em aumentos na potencia muscular. / Isokinetic dynamometers may be a viable alternative for improvements in neuromuscular and strength performance of knee flexors and extensors. However, the most advantages training protocol to elicit the greatest increases in hamstrings to quadriceps (H/Q) muscle balance is unknown. Therefore, the aim of this study was to compare three different isokinetic training protocols on H/Q strength balance, calculated by conventional and functional ratios. A secondary aim was to compare the training protocols across varied quadriceps and hamstrings muscle actions on concentric and eccentric peak torque (PT), isometric peak torque (IPT), rate of torque development (RTD), muscle activation (EMG), electromechanical delay (EMD), muscle thickness (MT) and echo-intensity (EI), as well functional performance tested by squat jump (SJ), counter movement jump (CMJ), drop jump (DJ) and 40m sprint tests. Forty untrained male subjects (22.87 ± 2.28 yrs, 70.66 ± 11.04 kg, 174.29 ± 6.9 cm) performed 6 weeks of training of their dominant and non-dominant knees on a Biodex isokinetic dynamometer. They were randomly assigned to 3 training groups; concentric quadriceps and concentric hamstrings (CON/CON), eccentric quadriceps and eccentric hamstrings (ECC/ECC), concentric quadriceps and eccentric hamstrings (CON/ECC) or no training (CNTRL). All training sessions were separated by at least 48 hours, and all variables were tested in 2 days 72h before and after training. Results revealed that the ECC/ECC group showed significant increases in functional ratio, as well as hamstrings and quadriceps eccentric PT, IPT, CMJ and DJ, compared to all other groups while the CON/CON group increased RTD (p<0.05). In addition, all training groups increased MT of quadriceps and hamstrings similarly (p<0.05). There were no differences between groups for concentric PT, EMG, ED, EI, SJ, conventional ratio or 40m sprint (p>0.05). Our findings suggest that ECC/ECC training may be the most effective at increasing functional H/Q strength ratio. Eccentric training increases eccentric strength, thereby increasing the functional H/Q strength ratio. Eccentric training also improves vertical jumps involving eccentric strength. CON/CON training may be more effective at increasing muscle power.
367

Análise do índice do arco plantar, equilíbrio postural e frequência do uso do salto alto em mulheres de diferentes faixas etárias / Analysis of plantar arch index, postural balance and use of high heel shoes frequency in women of different age groups

Dorneles, Patricia Paludette January 2013 (has links)
O presente estudo objetivou analisar a relação do índice do arco plantar com o equilíbrio postural e com a frequência do uso do salto alto entre mulheres de diferentes faixas etárias. Participaram do estudo 60 mulheres, 20 no grupo jovem (GJ), 20 no grupo adulto (GA) e 20 do grupo idoso (GI), as quais foram separadas em subgrupos com 10 indivíduos cada de acordo com a frequência do uso do salto alto. A avaliação da frequência do uso do sapato de salto alto foi realizada através do número de vezes que o indivíduo utilizava esse tipo de calçado. Para o cálculo do índice do arco plantar (IAP) utilizou-se o método de impressão plantar, por meio de um pedígrafo. Para a aquisição dos dados referentes ao equilíbrio postural foi utilizada uma plataforma de força AMTI; as variáveis utilizadas a partir do Centro de Pressão (COP) foram: amplitude de deslocamento ântero-posterior do centro de pressão (COPap), amplitude de deslocamento médio-lateral do COP (COPml), velocidade média de deslocamento do COP (COPvel) e área da elipse (elipse). Os resultados apontam que não houve correlações entre as variáveis do COP (COPap, COPml, velocidade e elipse) e o IAP na condição de olhos abertos e olhos fechados. Ao se tratar da faixa etária, houve diferença estatisticamente significativa entre o índice do arco plantar do GJ e GI e do GA e GI, indicando que o grupo de mulheres idosas possui um maior índice do arco plantar, ou seja, um rebaixamento no arco longitudinal medial. Com relação à frequência do uso do salto alto, não houve diferença estatisticamente significativa do índice do arco plantar entre os grupos. Concluiu-se que o índice do arco plantar não altera o controle postural em mulheres jovens, adultas e idosas deste estudo e que o grupo idoso apresenta um rebaixamento do arco longitudinal medial quando comparado com o grupo jovem e adulto. / The present study aimed to analyze the relationship between plantar arch index and postural balance and the frequency of use of high-heeled shoes among women of different age groups. The study included 60 women, 20 in the young group (GJ), 20 in the adult group (GA) and 20 in the elderly group (GI), which were separated into groups with 10 individuals each according to frequency of use of high-heeled shoes. The evaluation of the frequency of use of the high heel shoe was performed using the number of times that the person use this kind of footwear. To obtain the plantar arch index (IAP) was used the method of printing plant, with a plantar foot pressure. For acquisition of postural balance data was used a AMTI force plate and variables from the center of pressure (COP) used were: range of anteroposterior displacement of the center of pressure (COPap), range of displacement of the medial-lateral COP (COPml) and average speed of displacement of the COP (COPvel). The results showed that there were no correlations between the variables of COP (COPap, COPml, speed and ellipse) and IAP on eyes opened and eyes closed conditions. When dealing with the age group, there were statistically significant differences between the plantar arch index of the GJ and GI and of the GA and GI, indicating that the group of older women have an increased plantar arch index or a presents lower medial longitudinal arch. It was concluded that the plantar arch index does not alter postural control in young, adult and elderly people and that the elderly group presents lower medial longitudinal arch when compared with the young adult group showing.
368

Avaliação quantitativa de força de bochechas em humanos

Berbert, Monalise Costa Batista January 2013 (has links)
Atualmente, a avaliação da tonicidade de bochechas é realizada de forma perceptual e dependente da experiência do avaliador. Por esse motivo, este trabalho propôs uma alternativa para diminuir a subjetividade da forma de avaliação atual da força das bochechas, a qual pode complementar o diagnóstico fonoaudiológico. Desenvolveu-se um protótipo constituído de uma célula de carga acoplada a uma haste, sistema de conversão, amplificação e transmissão do sinal elétrico. Um estudo inicial buscou avaliar a repetitividade e reprodutibilidade de medições realizadas em sujeitos normais e alterados quanto à força das bochechas. Num segundo estudo visou-se quantificar e analisar a performance de indivíduos com força adequada. Os valores de força no sexo masculino, tanto para força média quanto para força máxima, foram estatisticamente maiores do que os valores entre o sexo feminino. Cinco tipos de curva caracterizam o comportamento da bochecha durante o ensaio. O método de avaliação quantitativa da força das bochechas desenvolvido colaborou para a diminuição da subjetividade da avaliação e foi capaz de registrar a força exercida pelas bochechas. / Currently clinical evaluation of cheeks tone is performed at a perceptual level and depends on the evaluator's experience. Therefore, this study aimed to propose an alternative way of reducing the subjectivity in cheeks strength assessments, which can complement the speech therapist diagnosis. We developed a prototype consists of a load cell coupled to a handle, the conversion system, amplification, and the electrical signal transmission. An initial study was toanalyze of repeatability and reproducibility of measurements performed in normal and abnormal individuals regarding cheek strength. In a second study sought to quantify and analyze the performance of subjects with adequate strength. The force values in males, both for strength and for average maximum force were statistically higher than the values among females. Five types of curve characterize the behaviour of the cheek during the test. The method of quantitative assessment of the cheeks strength developed helped to reduce the subjectivity of the evaluation and it was able to record the force exerted by the cheeks.
369

Avaliação do nível de esforço muscular durante diferentes estratégias de levantar-se de uma posição sentada

Vanassi, Juliana Collares January 2012 (has links)
A análise do movimento de levantar-se exige o conhecimento de fatores que influenciam na sua realização, sendo que os fatores relacionados à estratégia são aqueles oriundos da execução do movimento. A cinemática básica do movimento de levantar-se indica que antes da retirada dos glúteos do assento o movimento do quadril é predominante ao movimento da coluna lombar, com uma proporção quadril – coluna lombar de 3:1. Considerando o resultado de um modelo matemático, o esforço gerado na coluna lombar foi maior quando a tarefa de levantar-se foi executada com a proporção considerada correta. Dessa forma, o objetivo geral desse estudo foi verificar a relação do nível de esforço avaliado a partir de uma resposta mecânica, estimada por um macromodelo biomecânico tridimensonal, entre o nível de esforço avaliado pela eletromiogrfia dos músculos iliocostal, longuíssimo e multífido da região lombar e a percepção subjetiva de esforço (escala de Borg), durante diferentes estratégias cinemáticas e musculares de realizar a tarefa de levantar-se. Para isso, 20 participantes do sexo feminino executaram a tarefa de levantar-se usando duas diferentes estratégias cinemáticas e duas diferentes estratégias musculares, enquanto que dados cinemáticos, eletromiográficos e de percepção subjetiva de esforço foram coletados. O coeficiente de Correlação de Person foi utilizado para avaliar a correlação entre os diferentes parâmetros de medida. Foi encontrada uma correlação alta e positiva entre a força muscular resultante e a ativação muscular para cada uma das diferentes estratégias cinemáticas e musculares, enquanto que houve uma discordância entre os achados de força muscular resultante e a percepção subjetiva de esforço. / The rising movement demands a basic knowledge of factors influencing its achievement, and the factors related to the strategy are those derived from the execution of the movement. The rising movement’s basic kinematics indicates that before removing the gluteus from the seat hip movement is predominant to lumbar column movement, with hip/lumbar column proportion of 3:1. Considering the results of a mathematical model, the effort generated in the lumbar column was higher when the rising task was executed with the proportion considered correct. Thus, general objective of this study was to verify the relationship of the effort level assessed from a mechanical response, estimated by a tridimensional biomechanical macromodel, between the effort level evaluated by electromyography of the muscles iliocostalis, longissimus and multifidus of the lumbar region and perceived exertion (Borg scale), during different kinematics and muscular strategies for achievement the rising task. Twenty female participants performed the rising task using two different kinematics strategies and two different muscular strategies, while kinematics, electromyographic and perceived exertion data were collected. Pearson correlation coefficient was used for assessing the correlation between different measuring parameters. A high and positive correlation between resultant muscle force and muscle activation was found for each of the different kinematic and muscular strategies, while there was a disagreement between the findings of resultant muscle force and perceived exertion.
370

Desenvolvimento de um protótipo de sistema inteligente para análise da técnica de pedalada apresentada por ciclistas

Pigatto, André Vieira January 2018 (has links)
Este trabalho apresenta o desenvolvimento de um sistema inteligente para análise da técnica de pedalada aplicada por ciclistas. Para isso, desenvolveu-se um par de pedais de encaixe instrumentados, a partir dos quais é possível medir a componente de força normal aplicada nas partes frontal e posterior dos pedais. O modelo virtual da célula de carga experimental foi desenvolvido através da digitalização dos pedais de encaixe comerciais, utilizando-se um sistema comercial de escaneamento 3D com precisão declarada de 0,1mm. Cada pedal foi instrumentado com oito extensômetros de resistência elétrica (HBM 1-LY-13-1.5/350). Posteriormente os carregamentos máximos em cada eixo de medida de força foram estabelecidos utilizando-se uma plataforma de aquisição comercial específica para medida de deformação mecânica. Considerando-se os valores determinados, desenvolveu-se o circuito de condicionamento e realizaram-se os ensaios de deformação estática, obtendo-se as funções de transferência de saída de tensão elétrica em função do carregamento mecânico. O erro de linearidade máximo, considerando todos os canais, ficou abaixo de 0,75% e a máxima incerteza expandida (k=2) por canal, obtida através da aplicação do método clássico, foi de 1,55%. Em sequência, integrouse o sistema de pedais desenvolvido a dois outros sistemas, são eles: um par pedivelas experimentais instrumentados, capazes de medir as três componentes da força aplicada aos pedais e transmitidas aos pedivelas com um erro de linearidade abaixo de 0,6% e uma incerteza combinada inferior a 3,22%, e um sistema de cinemetria comercial, cuja precisão declarada pelo fabricante é de 1mm. Para possibilitar uma comparação quantitativa entre treinos ou ciclistas, implementou-se um sistema inteligente, baseado em redes Neuro-Fuzzy (ANFIS). A partir dos valores da potência média, do desvio padrão da potência e da assimetria bilateral média, obtidos ao longo de ensaios realizados sob protocolo desenvolvido especificamente para este trabalho, um score que representa o nível da técnica de pedalada apresentado pelo ciclista é determinado. Com intuito de testar o sistema, desenvolveu-se um projeto de experimentos com 2 fatores controláveis (sujeito e nível de frenagem de um rolo de treinamento), e realizou-se ensaios com oito ciclistas de características fisiológicas e níveis de preparos distintos. Através da análise estatística, constatou-se que das 23 variáveis de resposta consideradas ao longo do experimento, 23 são influenciadas significativamente pelo fator controlado sujeito e oito são influenciadas significativamente pelo fator controlado nível de frenagem magnética. / This report describes the development of an intelligent pedaling technique analysis system. To accomplish that, a pair of road bicycle pedals (SHIMANO R540) were instrumented to measure the forces that are applied to the front and back regions of the pedals. The virtual models of the pedals were developed based on a 3D scanned mesh developed with aid of a commercial 3D scanning system with a precision of 0.1mm. Each pedal was instrumented with eight electrical resistance strain-gages (HBM 1-LY-13-1.5/350). After that, the range of the mechanical deformation of each measurement channel was determined with aid of an industrial deformation acquisition system. The conditioning circuit was developed based on the mechanical deformation ranges previously determined and the static calibration experiment was performed to determine the voltage output transfer functions. The maximum linearity error determined per channel was 0,75% and the maximum expanded uncertainty (k=2), determined applying the classical methodology, was 1,55%. After that, the instrumented pedals developed were integrated with two complementary systems, which are: a pair of instrumented crank arm load cells which measure the components of the force applied to the bicycle pedal with a linearity error under 0.6% and an uncertainty of 3,22% and an Optitrack motion track system with a declared accuracy of 1mm. An intelligent pedaling technique analysis system was implemented through an Adaptive Neuro Fuzzy Inference System (ANFIS) to determine the cyclist pedaling technique score based on three inputs: the average power applied to bicycle pedal, the average power standard deviation and the bilateral asymmetry index, all of them collected under an experimental protocol specifically designed for this application. To evaluate the behavior of the system developed a randomized block experiment design with two controlled factors was performed indoor with aid of an ergometer roll; 160 sprints were conducted with eight subjects of different training levels. From the data collected an ANOVA test was performed, which confirmed that all the 23 response variables vary significantly in function of the subject’s controlled factor and eight of them vary significantly in function of the magnetic braking level.

Page generated in 0.0419 seconds