381 |
Desenvolvimento de um Gnatodinamômetro digital para estudo e análise da força dos músculos da mastigaçãoChimendes, Luis Henrique [UNESP] 16 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-07-16Bitstream added on 2014-06-13T19:04:55Z : No. of bitstreams: 1
chimendes_lh_dr_guara_parcial.pdf: 102180 bytes, checksum: c139799545de8eb6489ae9b428ed93b6 (MD5) Bitstreams deleted on 2015-06-03T11:42:48Z: chimendes_lh_dr_guara_parcial.pdf,. Added 1 bitstream(s) on 2015-06-03T11:44:12Z : No. of bitstreams: 1
000719103_20150816.pdf: 94202 bytes, checksum: 246baf1c1ceb743954ba0b217e2847fc (MD5) Bitstreams deleted on 2015-08-17T11:07:12Z: 000719103_20150816.pdf,. Added 1 bitstream(s) on 2015-08-17T11:07:57Z : No. of bitstreams: 1
000719103.pdf: 3521748 bytes, checksum: 05645957f1a416b064aaab6e5ef3f52b (MD5) / O tratamento das desordens temporomandibulares toma como base as informações colhidas durante a anamnese e o exame clínico do indivíduo. Com o objetivo de melhor compreensão da fisiopatologia que afeta os músculos do sistema estomatognático, o estudo da força destes músculos, tem sido incluído em muitos trabalhos, pois ajuda na escolha de um tratamento e verifica a eficiência do tratamento. O objetivo geral desse estudo foi construir um gnatodinamômetro com interface computacional a fim de analisar e comparar a força dos músculos da mastigação durante um experimento para mensuração da força de mordida na região dos incisivos. Para análise estatística, aplicou-se o teste de hipótese t a fim de comparar os valores das médias de indivíduos com e sem Disfunção Temporomandibular muscular. A amostra foi composta por 10 indivíduos com desordem temporomandibular sendo 5 mulheres e 5 homens e 10 indivíduos sadios, sendo 5 mulheres e 5 homens para controle, sem sinais ou sintomas de desordens temporomandibulares, segundo a classificação proposta pelo protocolo do Research Diagnostic Criteria for Temporomandibular Disorders. A mensuração da força de mordida foi realizada na clínica de desordens temporomandibular da AOESP. Conclui-se que existe diferenças estatísticas no valor médio da força de mordida , entre os grupos com DTM muscular e grupo Controle. Indivíduos sadios possuem valor médio de força de mordida maior em relação aos portadores de DTM. Indivíduos do gênero masculino possuem valor médio da força de mordida maior em relação ao gênero feminino. Obteve-se ainda neste estudo uma proposta de um gnatodinamômetro para análise da força dos músculos estomatogmático / The treatment of temporomandibular disorders builds on the information collected during history taking and clinical examination of the individual. Aiming at a better understanding of the pathophysiology that affects the muscles of the stomatognathic system, the study of the strength of these muscles, has been included in many studies as it helps in choosing a treatment and verifies the effectiveness of the treatment. The general objective of this study was to build a gnathodynamometer with computer interface to analyze and compare the strength of the muscles of mastication during an experiment to measure the bite force in the incisor region. Statistical analysis was applied to hypothesis test to compare the mean values for subjects with and without TMD muscle. The sample consisted of 10 healthy subjects and 5 women and 5 men and 10 subjects with temporomandibular disorder, 5 women and 5 men to control, without signs or symptoms of temporomandibular disorders, according to the classification proposed by the protocol of the Research Diagnostic Criteria for Temporomandibular disorders. Measurement of bite force was held in temporomandibular disorders clinic AOESP. We conclude that there is no statistical differences in the mean bite force between the muscle groups with TMD and control group. Healthy individuals have an average value of greater bite force in relation to TMD. Male individuals have average bite force higher compared to females. It was also observed in this study a proposal for a gnathodynamometer strength analysis of stomatognathic muscles
|
382 |
Avaliação do sincronismo do sinal eletromiográfico com o equilíbrio dinâmico de jogadores de futebol durante o chuteAmorim, César Ferreira [UNESP] 23 January 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-01-23Bitstream added on 2014-06-13T20:05:58Z : No. of bitstreams: 1
amorim_cf_dr_guara.pdf: 1558739 bytes, checksum: cf912517af4f1c4f658892c975ee2aa1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O controle postural é um fator determinante na execução de gestos funcionais que necessitam de um alto desempenho da coordenação motora, como por exemplo, nas atividades esportivas. Neste presente trabalho foi abordada a modalidade esportiva do futebol, e de forma mais específica, o gesto técnico do chute. Neste sentido, o objetivo deste trabalho foi de investigar o equilíbrio dinâmico durante o chute futebolístico por meio de um sistema de análise com uma tarefa controlada. O sistema proposto foi constituído por um dispositivo disparador vertical de bola, alvo de acerto, sistema de aquisição de sinais com eletromiografia, acelerômetria, registro do instante do acionamento do disparador, e por uma plataforma de força. A amostra foi constituída por 11 atletas profissionais de futsal, os quais realizaram a tarefa de vinte e cinco chutes ao alvo com a bola em movimento vertical. Para análise dos dados foi proposta a identificação e análise do comportamento dos sinais dos músculos Glúteo média (GM), Tibial anterior (TA), Fibular longo (FL) e Vasto lateral (VL), em relação às variáveis estabilométricas do equilíbrio postural no pré-chute, durante o chute e após-chute. Foram apresentados os gráficos das médias das variáveis estabilométricas: posição média, desvio padrão, deslocamento total, amplitude, velocidades, freqüências médias e freqüências medianas na direção ântero-posterior (AP) e médio-lateral (ML), centro de pressão (COP) e respectiva direção de oscilação, desenvolvidas durante a execução da tarefa controlada do chute. Os resultados apresentaram o comportamento das médias dos valores RMS (root mean square) dos músculos glúteo médio (GL), tibial anterior (TA), fibular longo (FL) e vasto lateral (VL) no pré-chute, durante o chute e pós-chute em relação a análise postural através do COP... / Postural control is a determining factor in the execution of functional movements that require a high performance of the motor control coordination, such as sporting activities. In this study the soccer sports activity was chosen, and more specifically, the technical movement of the kick. The objective this study was to investigate the postural sway through the kick’s movement control. A vertical ball shooting machine (VBS) with an active target was especially developed to measure the effectiveness of the kick. This system was synchronized with electromyographic signal, accelerometer and force platform in order to recognize the movement. Eleven professional athletes of soccer kicked the ball twenty-five times on target using the VBS system by EMG System do Brasil. Data analysis was proposed for identification and correlation of the signal behavior of the middle gluteus muscle (GM), tibialis anterior (TA), peroneus longus (FL) and vastus lateralis (VL) in relation stabilometric variables of postural sway before the kick, during the kick and after the kick. It was analysed of stabilometric variables: the mean position, standard deviation, total displacement, amplitude, speed, median frequencies in the anteroposterior (AP) and mediolateral (ML) of the center of pressure (COP ) and direction of oscillation during the controlled kick. The results showed the same trends in the behavior of the RMS (root mean square) of the gluteus medius muscle (LG), tibialis anterior (TA), peroneus longus (FL) and vastus lateralis (VL) before the kick during the kick and after the kick. This was also observed in the analysis of the variables stabilometric, standard deviation, speed, median frequency in anteroposterior (AP) and mediolateral (ML). Considering the results of this study, analysis of the behavior of EMG signals of the muscles involved in... (Complete abstract click eletronic access below)
|
383 |
Aspectos ergonômicos do levantamento manual de carga em mulheres: relação com equação de NIOSHOliveira, Danielle Rodrigues de [UNESP] 13 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-01-13Bitstream added on 2014-06-13T20:45:39Z : No. of bitstreams: 1
000733513.pdf: 3086583 bytes, checksum: 7197ec5f1df3355e56a5d9563cbe31e0 (MD5) / Atualmente, as mulheres estão atuando em áreas dentro da indústria, antes ocupadas somente por homens. A equação de NIOSH, amplamente empregada por ergonomistas para estimar as cargas de manipulação com base nos dados estatísticos de trabalhadores, aplica-se a 95% dos homens e 75% das mulheres. O método de avaliação em manipulação de cargas, aplicado nas indústrias, ainda carece de sensibilidade e precisão, uma vez que o movimento humano é bastante complexo e apresenta diferenças individuais no comportamento motor. Este estudo propõe uma nova metodologia para avaliar a manipulação de cargas com base nos dados individuais de antropometria, postura adotada e capacidade máxima de levantamento de carga. A postura foi identificada pela cinemetria 3D,a capacidade de levantamento de carga foi registrada por meio de uma célula decarga, a atividade muscular nos músculos eretores da coluna, longuíssimos e multífidos, foi avaliada por meio da eletromiografia de superfície e as forças internas (força de compressão,força de cisalhamento e momento) no disco intervertebral L5/S1 foram estimadas com base no modelo biomecânico da coluna vertebral de Chaffin, objetivando comparar com os dados apresentados na equação de NIOSH. A amostra compunha-se de 12 participantes, do sexo feminino,idade 25,7 ± 4,3 anos, massa de 57,7 ± 7,0 kg, altura de 1,6 ± 0,1 m e IMC entre 18,5e 24,9.Os procedimentos de levantamento de cargasforam realizados com uma carga pré-determinada, de acordo com a NIOSH,na altura fixa do chão de 23 cm atéa adoção dapostura ereta, sem rotação do tronco e com cotovelos fletidos a 90o, sendo a frequência de levantamento relativamente baixa. Os testes estatísticos aplicados neste estudo foram: ANOVA one-way e Teste tpareado, sendo a significância estatística adotada de = 10% (p<0,10). Os resultados deste estudo sugerem que se deve... / Now a days, women are working in areas within the industry, previously occupied by men only. The NIOSH equation, widely used by ergonomists to estimate handling charges with base on the statistical data of employees, applies to 95 %ofmen and75 % of women.The evaluation method for handling of loads,applied in industries, still lacks sensitivity and precision, since human motion is complex and presents individual differences in motor behavior. This study proposesa new methodology to evaluate thehandling of loads with base on individual data of anthropometry, adopted posture and maximum capacity for lifting load. The posture was identified by 3D cinemetry, the capacity for lifting load was recordedby aload cell, the muscle activity in the spine erectormuscles, multifidusand extremely long, was evaluated by surface electromyography and the internal forces (compression force, shearforce and moment) in the intervertebral disc L5/S1 were estimated with base on Chaffin biomechanical model of thespine, in order to compare with the data presentedin the NIOSH equation.The sample consisted of 12 participants,female, age 25,7 ± 4,3 years, weight 57,7 ± 7,0 kg,height 1,6 ± 0,1 m and IMC between 18,5and 24,9. The procedures for lifting loads were performed with a predetermined load, according toNIOSH, the fixed heightof 23 cm from the floor to the adoption of theupright posture, without torso rotation and with elbow flexed 90 °, being the frequency of lifting relatively low.The statistical analyzes used in this study were ANOVA one way and Paired T Test, andthe statistical significance adopted for = 10 % (p < 0,10). The resultsof this study suggest that one shouldconsider the maximum capacity of individual lifting to establish the recommended load. With the index NIOSH (IN) proposed in this study, different the lift index (IL), it is possible to determine the individual ... (Complete abstract click electronic access below)
|
384 |
Análise do equilíbrio dinâmico do membro inferior em uma situação de instabilidade provocada pela prancha de equilíbrio e tênis instáveisSilva, Glauce Gonzaga [UNESP] 13 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:34:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-01-13Bitstream added on 2014-06-13T20:45:40Z : No. of bitstreams: 1
000733650.pdf: 2558316 bytes, checksum: 8ecbdb2f984832ce1175bef38547929b (MD5) / O equilíbrio corporal é um evento dinâmico que está diretamente relacionado à independência funcional do indivíduo. O objetivo do presente estudo foi investigar a influência de diferentes tipos de calçados e da imobilização da articulação do tornozelo sobreos componentesbiomecânicos do equilíbrio dinâmico.Doze mulheres saudáveis (idade: 27,08± 4,79 anos,IMC: 22,58 ± 2,17 kg/m2) foram analisadas durante uma tarefa de oscilação corporal ântero-posterior sobre umaprancha de equilíbrio em quatro condições: descalças, usando tênis habitual, usando tênis instáveis e com o tornozelo dominante imobilizado em 50% de sua total amplitude de movimento. As análises consistiram em duasetapas: realização da contração voluntária máxima (CVM), condição estática, e oscilação livre, condição dinâmica.Uma plataforma de força foi posicionada sobrea prancha deequilíbrio para avaliar as distribuições das forças de reação. A análise cinemática tridimensional foi realizada para avaliar as oscilações daprancha, do centrode massa edos ângulos articulares do tornozelo. Foi realizadaanálise eletromiográficados músculos reto femoral, tibial anterior,gastrocnêmio medial e lateral do membro dominante. Os valores foram comparados por análise de variância one way e teste T pareado(p<0,10). A análise dinamométrica revelou maior força vertical dereação do solo durante a oscilação anteriorem relaçãoà posterior (p< 0,001). A condição de imobilização foi significativamente maior em relação às demais (p=0,049 para todas). Na análise cinemática, maior ângulo de inclinação da prancha durante a oscilação posterior foi observado (p=0,001). A análise eletromiográfica revelou maior ativação na condição de imobilização (p = 0,08). A maior amplitude de oscilação anterior em relação à posterior... / Body balance is a dynamic event that is directly related to the functional independence of individual. Thepurpose of this study was to investigate the influenceof different typesof shoes and immobilization of the ankle joint on the mechanical componentsof dynamic equilibrium. Twelve healthy women(age: 27.08 ± 4.79 years;BMI: 22.58 ± 2.17 kg/m2) wereanalyzed duringa task anteroposterior body sway on a balanceboard for four conditions: barefoot, with a regular tennis, with an unstable shoes andwith dominant ankle immobilized at 50% of itsfull range of motion. Analysisconsistedof two steps: achievement of maximumvoluntary contraction (MVC), static condition, andfree oscillation, dynamiccondition. One force platformwas properly positioned on the balance board to evaluate the distributions of the reaction forces. Three-dimensional kinematic analysis was performedto evaluate the fluctuationsof the mass center. Electromyographic analysis of therectus femoris,tibialis anterior, medial and lateralgastrocnemius of thedominant limb was performed. Values were compared by one way variance analysis and pared t-test (p<0,10).Dinamometricanalysis showed greater vertical ground reaction force during theanterior body away compared to posteriorbody away (p<0,001). Immobilization condition was significantly higher compared to all conditions (p=0.049 for all). In kinematic analysis, a greater angle of inclination of the board during the posterior body away was observed (p=0,001). Higher activation in immobilization condition was observed in relation to other (p=0,08). Equality of electromyographic values of other muscles investigated was due the co-contraction performed during the oscillations. The largest amplitude of anterior body away compared to the posterior oscillation reflects better conditions fall protection in immobilization condition. Ankle and hip strategies were activated of effective ... (Complete abstract click eletronic access below)
|
385 |
Avaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexõesDelben, Juliana Aparecida [UNESP] 25 October 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-10-25Bitstream added on 2014-06-13T20:06:14Z : No. of bitstreams: 1
delben_ja_dr_araca.pdf: 2204033 bytes, checksum: 1d373c26a850bd8e588c8abb0d735054 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: A performance de restaurações cerâmicas parafusadas a implantes com diferentes conexões diante de fadiga é um fator importante para o sucesso do tratamento. Proposição: O objetivo do estudo foi avaliar a confiabilidade e o modo de falha de coroas cerâmicas obtidas com pilares de zircônia parafusadas a implantes osseointegráveis de diferentes conexões. Material e método: Foram formados 3 grupos de acordo com as diferentes conexões pilar-implante: Grupo EH - hexágono externo, Grupo IH - hexágono interno e Grupo MT - Cone Morse. As coroas foram obtidas através da aplicação de cerâmica de revestimento sobre pilar de zircônia utilizando a técnica de aplicação em camadas e parafusadas aos implantes com parafusos de retenção específicos para cada sistema. Os espécimes foram submetidos ao teste de fadiga acelerado step-stress de acordo com os perfis leve (n=9), moderado (n=6) e agressivo (n=3) determinados após teste de resistência à fratura (n=4) em máquina de ensaio universal. Os dados foram inicialmente avaliados pela análise de use level probability Weibull. Os valores e intervalos de confiabilidade foram obtidos através de standard probability calculation. Considerando os valores de carga para a falha dos espécimes, foi calculada a distribuição de Weibull. Análise fractográfica foi conduzida através de estereomicroscopia e microscopia eletrônica de varredura. Resultado: O valor de β de todos os grupos (EH-β= 0,6307; IH-β=0,9730; MT-β=0,1942) sugere que as falhas foram mais associadas ao nível de carga do que ao dano acumulado. Os valores de confiabilidade para uma missão de 50.000 ciclos e carga de 400 N foram de 97% para o grupo EH, 46% para o grupo IH e 0,5% para o grupo MT com... / Introduction: The performance of screw-retained all-ceramic crowns attached to implants with different connections under fatigue is a relevant factor for treatment success. Purpose: The aim of this study was to evaluate the reliability and failure mode of screw-retained all-ceramic crowns fabricated with zirconia abutments attached to osseointegrated implants with different connections. Material and method: Three groups were designed according to the implant-abutment connection: Group EH - external hexagon, Group IH - internal hexagon and Group MT - Morse taper. Layering technique was used for veneering of zirconia abutments. The crowns were attached to the implants with the retention screws of each system. Step-stress accelerated fatigue test was conducted according to mild (n=9), moderate (n=6) and aggressive (n=3) profiles determined after single-load-to-fracture test (n=4) in a universal testing machine. Data was previously analyzed by use level probability Weibull. Standard probability calculation was used to determine the reliability and confidence bounds. Weibull distribution was calculated based on the load to failure. Failure modes were described under light polarized microscopy and scanning electron microscopy. Result: β of all groups (EH-β= 0.6307; IH-β=0.9730; MT-β=0.1942) suggested that failure was associated to load instead of cumulative damage. Significant difference was observed between the groups for the calculated reliability in a mission of 50,000 cycles at 400 N (97% for group EH, 46% for group IH... (Complete abstract click electronic access below)
|
386 |
Desenvolvimento de um equipamento para análise de desgastes em prótese de articulação total de quadril / Development of an equipament for analysis of wear of the componentes of total hip prosthesisHaddad, Michel [UNESP] 07 January 2015 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:10Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-01-07Bitstream added on 2015-04-09T12:48:06Z : No. of bitstreams: 1
000817132.pdf: 851137 bytes, checksum: e912d75616dc0496ca2afdbf7e4e1583 (MD5) / O incremento da renda brasileira aliado ao aumento da expectativa de vida, juntamente com outros fatores, propiciaram condições para a elevação da demanda por cirurgias de prótese de articulação total de quadril. A ausência de uma norma reguladora para a durabilidade mínima destas próteses fez surgir no mercado uma grande variedade de produtos que não atendem requisitos mínimos de uso, causando elevado número de cirurgias mal sucedidas e trazendo transtornos aos pacientes. Os ensaios para verificação da durabilidade das próteses realizados no território nacional utilizam, em sua maioria, equipamentos importados, com alto grau de sofisticação, tornando-os de custo elevado. Sendo o Sistema Único de Saúde (SUS) o maior adquirente destas próteses, torna-se inviável manter uma rotina de ensaios com a finalidade de avaliar a qualidade do produto a ser adquirido e oferecido aos pacientes. O projeto e montagem de um equipamento viável nas etapas de fabricação, operação e manutenção visa atender esta demanda com maior abrangência, proporcionando ensaios acessíveis. O atendimento das normas específicas, com alguns ajustes, viabilizou a operação do equipamento e as análises de exemplares de próteses, o que comprovou a viabilidade do projeto e o seu grau de atendimento a necessidade da realidade brasileira. Foi realizado um teste realizado com um conjunto protético por um período de 12 dias, totalizando 1 milhão de ciclos. Ao final obteve-se o desgaste da massa do componente acetabular em polímero, e calculou-se o fator de desgaste (K). O simulador apresentou funcionamento adequado, produziu o perfil da carga prescrita pela Norma Técnica e o fator de desgaste obtido foi considerado adequado / The increase of Brazilian income coupled with the increase in life expectancy, along with other factors, led to the conditions for the rise of demand for surgeries of total hip joint prosthesis. The absence of a regulatory standard for the minimum durability of these prostheses did arise on the market a great variety of products that do not meet minimum requirements of use, causing large numbers of unsuccessful surgeries and bringing patients disorders. The tests for verification of the durability of prosthetics carried out in national territory using, for the most part, imported equipment, with a high degree of sophistication, making them high cost. Being the Sistema Único de Saúde (SUS) the largest purchaser of these prostheses, it becomes impossible to maintain a routine tests in order to evaluate the quality of the product to be purchased and offered to patients. The design and assembly of a viable equipment in stages of manufacturing, operation and maintenance aims to meet this demand with greater scope, providing affordable tests. Meet the specific standards, with some adjustments, made the operation of the equipment and the analysis of specimens of prostheses, which proved the feasibility of the project and its degree of care the need of Brazilian reality. It was conducted a test performed with a prosthetic assembly for a period of 12 days, totalizingng 1 million cycles. At the end, it was obtained the mass wear of the acetabular component in polymer, and it has been calculated the wear factor (K). The simulator showed proper functioning, produced the prescribed load profile by Technic Norm and the wear factor obtained was considered appropriate
|
387 |
Análise de parâmetros cinéticos em mulheres com Síndrome da Dor Femoropatelar no gesto de subida de escadaSilva, Danilo de Oliveira [UNESP] 20 February 2015 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-20Bitstream added on 2015-05-14T16:59:23Z : No. of bitstreams: 1
000823539.pdf: 1465326 bytes, checksum: 4196da63f7a27d7956aeec7cf990dcdb (MD5) / A Síndrome da Dor Femoropatelar é exacerbada durante atividades funcionais, como subir degraus. Apesar de sua etiologia permanecer indefinida, sabe-se que ocorrem problemas no alinhamento do membro inferior acometido, decorrente de alterações locais, distais e proximais a patela. O estudo das forças de reação do solo e deslocamento do centro de pressão durante a subida de escadas é pouco utilizado para análise da Síndrome da Dor Femoropatelar, entretanto, identificar e entender se existe e como se dão essas alterações é extremamente importante para o entendimento desta disfunção. Neste contexto, este projeto tem como objetivo geral investigar os padrões dinâmicos cinéticos em mulheres com Síndrome da Dor Femoropatelar, durante subida de escadas. Foram recrutadas 62 mulheres para participarem do estudo, 31 com Síndrome da Dor Femoropatelar e 31 assintomáticas. As participantes subiram 5 vezes uma escada instrumentada de 7 degraus, com uma plataforma de força embutida no quarto degrau. Foram extraídos parâmetros referentes ao centro de pressão e da força vertical de reação solo... / Patellofemoral Pain Syndrome often affects athletes and sedentary population, causing anterior knee pain that is exacerbated during functional activities such as climbing stairs. Despite its etiology remains inconclusive, it is known that problems occur in the affected lower limb alignment, resulting from changes in local, distal and proximal to the knee. The study of ground reaction and center of pressure displacement during stair climbing is hardly used for Patellofemoral Pain Syndrome analysis, however, identify and understand if there is and how these changes occur is extremely important for Patellofemoral Pain Syndrome understanding. In this context, the aim of this project was investigating kinetic dynamic patterns in women with Patellofemoral Pain Syndrome during stair climbing. 62 women were recruited to participate in the study, 31 with Patellofemoral Pain Syndrome and 31 pain free. The participants performed 5 stair ascents under an instrumented 7 steps stairs with an embedded force platform on the fourth step. Parameters related to the center of pressure and the vertical ground reaction force were extracted...
|
388 |
Análise biomecânica do chute frontal de karatê: implicações em lesões nos membros inferiores / Biomechanical analysis of the front kick karate: implication in lower limb injuriesSantos, Paulo José Moraes de Paula [UNESP] 20 February 2015 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:11Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-20Bitstream added on 2015-05-14T16:59:16Z : No. of bitstreams: 1
000824701.pdf: 961443 bytes, checksum: b207e1ce82ef8c0c848bc14aab92265d (MD5) / O karatê é uma modalidade esportiva ainda em ascensão. Neste estudo, a implicação do golpe de karate foi avaliada utilizando princípios biomecânicos. Um dos intuitos é ajudar na epidemiologia das lesões nos esportes e, no karatê, o chute frontal é um dos golpes mais utilizados, sendo, ao mesmo tempo, os membros inferiores os locais mais acometidos por injúrias. O objetivo desta pesquisa foi correlacionar o pico de aceleração do movimento e suas implicações para a lesão nos membros inferiores dentro do karatê, além de verificar a atuação da musculatura do Reto Femoral durante a execução do golpe. Este trabalho estuda a técnica do chute frontal Mae Geri, por meio da Cinemetria, da Eletromiografia e dos dados do pico de aceleração do golpe. A coleta em laboratório foi realizada com 8 atletas, sendo 7 do sexo masculino e 1 do sexo feminino. Cada praticante realizou 10 sendo 5 em posição estática e 5 em posição dinâmica. A aceleração foi verificada por um acelerômetro acoplado a uma chapa de aço protegida, fixada em uma estrutura metálica, ajustada à altura do atleta. Os resultados obtidos foram comparados com os dados existentes na literatura sobre a relação entre o pico de aceleração e o modo pelo qual as lesões ocorrem. Assim, a presente pesquisa verificou que o chute frontal estudado desenvolve uma grande aceleração, sendo esta não obrigatoriamente ligada à massa do sujeito, podendo ser lesiva aos praticantes da modalidade, além disso, os valores de RMS obtidos através da análise eletromiografica do Reto Femoral apontam que não necessariamente o chute que mais requisita a musculatura é aquele que ira desenvolver uma maior aceleração / Karate is a sport still on the rise. In this study, the implication of karate blow was evaluated using biomechanical principles. One of the purposes is to help in the epidemiology of injuries in sports and in karate, the front kick is one of the most used strokes, while at the same time, the legs were the most affected sites due to injuries. The aim of this study was to correlate the peak acceleration of the movement and its implications for the injury in the lower limbs in karate and to verify the performance of the Straight femoral muscles during blow execution. This work studies the technical front kick Mae Geri, through the kinematics of Electromyography and data peak Bang acceleration. The collection was carried out in the laboratory with 8 athletes, 7 males and 1 female. Each practitioner held 10 and 5 in a static position and 5 in dynamic position. The acceleration was detected by an accelerometer coupled to a protected steel plate fixed to a metal frame adjusted to the athlete's height. The results were compared with data in the literature on the relationship between peak acceleration and the way that injuries occur. Thus, the present study found that the front kick studied develops a great acceleration, which is not necessarily linked to the weight of the subject, and may be detrimental to practitioners of the embodiment, moreover, the RMS values obtained by analysis of the electromyographic Straight femoral link not necessarily the most kick that orders the muscle is one that will develop greater acceleration
|
389 |
Sistema de avaliação e tratamento da coluna lombar com o uso de tração mecânica / System evaluation and treatment of the lumbar spine using mechanical tractionCarvalho, André Sólon de [UNESP] 05 February 2015 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:18Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-02-05Bitstream added on 2015-05-14T16:59:03Z : No. of bitstreams: 1
000825172.pdf: 1169211 bytes, checksum: 6ea62b494664f697da481d8884dc9fd8 (MD5) / Segundo a Organização Mundial da Saúde (OMS), os distúrbios da coluna vertebral acometem cerca de 85% da população mundial em alguma fase de sua vida, sendo a segunda causa de incapacidade de trabalho na vida adulta. A hérnia de disco lombar é uma das doenças mais frequentes na prática clínica dos neurocirurgiões e ortopedistas, no entanto, o tratamento, ao contrário do que muitos pensam, é a princípio conservador, ou seja, a cirurgia é indicada somente em pacientes com sintomas refratários ao tratamento com fisioterapia e osteopatia, pois é comum o paciente não se recuperar rapidamente, e até 38% dos pacientes operados podem necessitar de novas cirurgias. A tração lombar é uma poderosa ferramenta para o reposicionamento articular e a liberação da compressão nervosa evitando assim, em um grande número de casos, uma intervenção cirúrgica. Neste trabalho foi desenvolvida uma maca capaz de realizar tração lombar mecanicamente monitorada, apresentando três novas metodologias para tratar e avaliar o uso da tração mecânica para a coluna lombar. A primeira, é a utilização de um eletroestimulador funcional (FES), para a correta colocação dos eletrodos de superfície do eletromiógrafo (EMG), fator este que minimiza o erro na coleta de dados. A segunda, é o posicionamento do paciente em decúbito ventral, que favorece a tração devido a anatomia da coluna lombar. A terceira é a tração dinâmica capaz de realizar a tração com movimento contínuo de flexo-extensão. Para avaliar a eficiência do sistema foram avaliados 10 (dez) voluntários, sendo descritos os dados de angulação, magnitude da força ou carga ideal aplicada, tempo e frequência da tração. Conclui-se neste estudo, um melhor aproveitamento dos benefícios da tração lombar e acreditando-se que os valores gerados servem como contribuição para auxílio do tratamento na protrusão e hérnia de disco da coluna lombar / According to World Health Organization (WHO), disorders of the spine affect about 85% of world population at some stage in their life, being the second leading cause of work disability in adulthood. A herniated lumbar disc is one of the most common diseases in clinical practice by neurosurgeons and orthopedic surgeons, however, the treatment, contrary to what many believe is the conservative principle, surgery is indicated only in patients with symptoms refractory to treatment with physiotherapy and osteopathy, as is common for the patient does not recover quickly, and up to 38% of patients may need more surgery. The pull back is a powerful tool to reposition the joint and release of nerve compression, thus avoiding a large number of cases, surgery. For this it developed in this work a stretcher capable of performing lumbar traction, with three innovations: first, the use of an electro (FES) for the correct placement of electrodes surface electromyography (EMG) factor that minimizes the error in data collection. The second is the positioning of the patient in a supine position, a factor that favors the draw, because the anatomy of the lumbar spine. The third, dynamic traction, table has the ability to perform traction during flexion-extension movement. To assess the efficiency of the system were evaluated ten (10) volunteers, data angle, and magnitude of applied force or load ideal, time and frequency drift. The conclusion of this study was a better use of the benefits of lumbar traction and it is believed that the values generated serve as a scientific contribution to aid in the treatment of pathologies of the lumbar spine
|
390 |
Implementação de um sistema de aquisição de dados da técnica de judô Osotogari utilizando dummy na realização do uchikomi / Implementation of a data acquisition system for judo technique Osotogari on uchikomi, applying dummyNagata, Eduardo Yoshinori [UNESP] 15 January 2015 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:24Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-01-15Bitstream added on 2015-05-14T16:58:52Z : No. of bitstreams: 1
000825292.pdf: 1544038 bytes, checksum: eebdf11dfc6887834c5cb56e25c53d9d (MD5) / O judô é um esporte muito praticado no mundo todo, sendo uma modalidade que exige boa condição física para a melhor performance. Para a execução dos golpes é necessária a coordenação das ações dos membros superiores e inferiores, assim como a força exercida pelos membros ser sincronizada para atingir eficiência no gesto motor. O presente estudo teve por objetivo construir um equipamento de avaliação de desempenho para verificar o comportamento dos sinais de força na execução da técnica de judô Osotogari no treinamento de uchikomi. O equipamento de avaliação de desempenho confeccionado com 4 células de carga que foram posicionados nos 4 contatos do uke (pessoa que recebe o golpe) no tori (pessoa que executa o golpe) ao realizar o golpe. O equipamento foi construído num dummy com uma célula de carga acoplada no peito esquerdo, outra célula de carga posicionada na parte posterior da coxa direita. O dummy foi vestido com um kimono adaptado, e nele foram colocados uma célula de carga na manga direita e outra célula de carga na gola esquerda. Participaram da pesquisa 12 sujeitos com dominância lateral direita, sendo 5 experientes e 7 iniciantes. Os sujeitos realizaram 1 série de 10 repetições do Osotogari. Verificou-se diferença significativa (p < 0,05) entre os sujeitos experientes e iniciantes nos valores de força da célula de manga e célula de gola. Os valores de força da célula da perna e célula do peito não apresentaram diferença significativa. Foi observado média correlação linear entre os valores de pico da força da célula de manga e de gola, que pode ser explicado pelo sincronismo temporal e ritmo que é empregado pelas duas mãos. Foi verificado que há um instante ideal para aplicar a força para se obter um melhor desempenho na execução do golpe. A utilização do dummy tem o intuito de suprir a ... (Resumo completo, clicar acesso eletrônico abaixo) / Judo is a worldwide practiced sport which requires physical fitness for better performance. For the fulfilment of the techniques, it is necessary the coordination of lower and inferior limbs, as well as the synchronization of power delivered by the limbs to achieve efficiency on the gesture. The objective of the present study was to develop an equipment for the performance evaluation of the judo technique Osotogari during uchikomi training, through the behavior of strength signals. The device had 4 load cells placed on four locations of the uke’s body (one who receives the technique) on the tori (one who performs the technique) while applying the technique. The device as built based on a dummy, with one load cell placed on the left side of the chest, other on the back side of the right thigh. The dummy was dressed in a adapted kimono, that received a load cell on the right sleeve and another one on the left side collar. 12 subjects of right side dominance took part on the survey, 7 of them were beginners and 5 were experienced. Each of these subjects performed 1 serie of 10 repetitions of Osotogari. A significant difference was observed between experienced subjects and beginners for the sleeve and the collar load cells data. In the other hand, no significant difference was observed on the chest and thigh load cells. Moderate linear correlation was observed between peak force data of the sleeve and collar load cells, which can be explained by the hands’ temporal synchronization and rhythm. It was observed that there is an ideal moment to apply strength when performing the technique, in order to achieve better performance. The dummy is intended to meet the need for more practical performance analysis methods, contributing this way to the advance in athletes training
|
Page generated in 0.0427 seconds