• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Övervakning av blybatterier under långa transporter

Borgedahl, Malin, Sporrong, Elias January 2023 (has links)
Blybatterier är ett uppladdningsbart batteri som har utvecklats i över 100 år och används i ett brett spektrum där det krävs en långvarig och pålitlig strömkälla. Däremot har blybatterier en begränsad livslängd och kapacitet som styrs av underhållet av batteriet. En faktor som påverkar batteriets kapacitet är sulfatering, vilket sker när batteriet urladdas och stått med en låg laddningsstatus under en lång tid. När transporter av blybatterier sker är det därför viktigt att ha tillförlitliga och säkra processer för att säkerställa batteriets kvalitet genom hela transportkedjan. Syftet med denna studie var att ta fram konceptmodeller genom att undersöka och identifiera olika metoder för att säkerställa kvaliteten på blybatterierna under långa transporter. Konceptmodellernas syfte var även att öka livslängden på blybatterierna med hänsyn till användarvänlighet och miljöpåverkan. Följande forskningsfrågor har besvarats: I. Hur kan företag inom tillverkningsindustrin säkerställa kvalitet på ett blybatteri under långa transporter?II. Hur kan urladdning av blybatterier undvikas genom övervakning av batteriet? En fallstudie har genomförts på Volvo CE, ett globalt företag som verkar inom interkontinentala och regionala transporter. I Pedeneiras, Brasilien, etablerades en produktionsanläggning år 1995 för anläggningsmaskiner som sedan levereras till återförsäljare i Nord- och Sydamerika samt Australien. Anläggningsmaskinerna har ett 24 V-system som innehåller två stycken seriekopplade 12 V blybatterier. Transporten för anläggningsmaskinerna från produktionsanläggningen till återförsäljare kan ta upp till två månader vilket innebär att batterierna riskerar att självurladdas och blir permanent skadade. Semistrukturerade intervjuer genomfördes på Volvo CE i Eskilstuna, Volvo GTT samt produktionsanläggningen i Pederneiras, för att samla in relevant data. Parallellt har en litteraturstudie utförts för att utforska tillgängliga teknologier samt tekniker för att underhålla laddningen och mäta batteriets status. Studien resulterade i tre stycken konceptmodeller som bygger på den empiriska data samt teknologier som framkom under litteratursökningen. Konceptmodell I är ett förslag på implementering av ett individuellt serienummer på blybatterierna. Denna lösning skapar transparens genom att kunna spåra batterierna, identifiera och logga batteriets status när maskinen har lämnat produktionsanläggningen. Genom att sammankoppla detta med digitala verktyg möjliggörs spårning av det individuella batteriet. Konceptmodell II innebär att en batterisensor placeras på batteriet som med fjärrstyrning möjliggör övervakning av batteriets status och position. Detta innebär att batteriet kan övervakas på distans i realtid och användaren varnas automatiskt om batteriets spänning är för låg. Detta innebär att batteriet kan laddas upp innan det förlorat sin kapacitet vilket har en positiv inverkan på miljön samt användarvänligheten. Konceptmodell III är en utökning av föregående koncept men innebär att underhållsladdningen automatiseras med solpaneler och laddningsregulator. Lösningen tar hänsyn till både användarvänligheten och miljöpåverkan genom att säkerställa att batteriet inte urladdas.
2

Detection of lithium plating in lithium-ion batteries / Detektering av litiumplätering i litiumjonbatterier

Björkman, Carl Johan January 2019 (has links)
With an increasing demand for sustainable transport solutions, there is a demand for electrified vehicles. One way to store energy on board an electrified vehicle is to use a lithium-ion battery (LIB). This battery technology has many advantages, such as being rechargeable and enabling reasonably high power output and capacity. To ensure reliable operation of LIB:s, the battery management system (BMS) must be designed with regards to the electrochemical dynamics of the battery. However, since the battery ages over time, the dynamics changes as well. It is possible to predict ageing, but some ageing mechanisms can occur randomly, e.g. due to variations of circumstances during manufacturing, and variations of battery user choices. Hence, by monitoring ageing mechanisms in situ, the BMS can adapt accordingly, similar to a closed loop control system. One ageing mechanism in LIB:s is lithium plating. This mechanism signifies when Li ions are electrochemically deposited as metal onto the negative electrode of the LIB during charging, and can induce other ageing mechanisms, such as gassing or electrolyte reduction. The present project has investigated a method for detecting Li plating in situ after its occurrence by both analysing the voltage change over time during open-circuit voltage (OCV) periods after charging and monitoring battery swelling forces. Results show a correlation between a high probability of Li plating and the appearance of a swelling force peak and an OCV plateau. However, results also show a possible correlation between the onset of Li plating and the onset of the swelling force peak, while also showing a greater detectability of the force signal compared to the electrochemical signal. Furthermore, the present results show that the magnitudes of both signals are probably related to the amount of plated Li. The amount of irreversibly lost Li from plating is shown to have a possible correlation with accumulation of swelling pressure. However, to further validate the feasibility of these two signals, more advanced analysis is required, which was not available during this project. / Med en ökande efterfråga på hållbara transportlösningar så finns det ett behov av elektrifierade fordon. Ett sätt att lagra energi ombord ett elektrifierat fordon är att använda et litium-jon-batteri. Denna batteriteknologi har många fördelar: t.ex. är dessa batterier återladdningsbara, och de kan leverera höga uteffekter samtidigt som de kan ha ett stort energiinnehåll. för att säkerställa en säker drift av litium-jon-batterier måste batteriets styrsystem vara designat med hänsyn till den elektrokemiska dynamiken inuti batteriet. Dock åldras batteriet med tiden, vilket innebär att denna dynamik ändras med tiden, vilket innebär att styrningen av batteriet måste anpassa sig till denna föråldring. Det är möjligt att förutspå åldring av batterier, men vissa åldringsmekanismer kan ske slumpartat, t.ex. via slumpmässiga förändringar i tillverkningsprocessen av batteriet, eller variationer i användningen av batteriet. Genom att därmed bevaka dessa åldringsmekanismer in situ så kan styrsystemets algoritm anpassa sig utmed batteriåldringen, trots dessa slumpartade effekter. En åldringmekanism hos litium-jon-batterier är s.k. litiumplätering. Denna mekanism innebär att litium-joner elektrokemiskt pläteras i form av metalliskt litium på ytan av litium-jon-batteriets negativa elektrod. Mekanismen kan också inducera andra åldringsmekanismer, t.ex. gasutveckling eller elektrolytreduktion. Detta projekt har undersökt en metod för att detektera litiumplätering in situ efter att plätering har skett, genom att både analysera öppencellspänningens (OCV) förändring med tiden direkt efter uppladdning samt analysera de svällande krafterna som uppstår under uppladdning av batteriet. Resultaten visar på en korrelation mellan en hög sannolikhet för litiumplätering och observationen av en topp i svällningskraft och en platå i OCV-kurvan. resultaten visar också en möjlig korrelation mellan påbörjandet av litium-plätering och påbörjandet av toppen i svällningskraft. Vidare visar även resultaten ett troligt samband mellan signalernas magnitud och mängden pläterat litium. Slutligen visar resultaten också ett möjligt samband mellan irreversibelt pläterat litium och ett svällningstryck som ackumuleras med varje uppladdningscykel. Dock krävs det en validering med mer avancerade analysmetoder för att säkerställa användningsbarheten av dessa två signaler, vilket ej var möjligt inom detta projekt.

Page generated in 0.1155 seconds