• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 1
  • Tagged with
  • 50
  • 41
  • 17
  • 15
  • 15
  • 12
  • 11
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Modelagem estatística em estudos de bioequivalência sob o enfoque Bayesiano / Statistical modeling in bioequivalence studies under Bayesian approach.

Souza, Roberto Molina de 15 April 2015 (has links)
O interesse pelos estudos de bioequivalência iniciou-se na década de 60, sendo o FDA (EUA) a primeira agência reguladora a se interessar por esta questão. No Brasil, uma lei de 1999 regulamentou o medicamento genérico no país, sendo este um importante meio de acesso aos medicamentos pela população e fazendo parte da política de medicamentos do SUS. No Brasil, a ANVISA e responsável por inspecionar os centros de bioequivalência bem como dar as diretrizes para estes. Um modelo paramétrico padrão para a etapa estatística e disponibilizado para a decisão de bioequivalência media e espera-se que este ajuste-se aos dados obtidos nos estudos de bioequivalência, o que nem sempre acontece. Neste sentido, e proposto nesta tese o uso de modelos paramétricos mais abrangentes baseados em outras distribuições de probabilidade para a decisão de bioequivalência media e que possam modelar a assimetria dos dados, dispensando o uso da transformação logarítmica para os parâmetros farmacocinéticos o que afeta a amplitude dos limites de bioequivalência. Propõe-se também o uso de modelos bivariados para a tomada conjunta da decisão de bioequivalência media, quando são analisados simultaneamente dois parâmetros farmacocinéticos. Foram utilizados métodos Bayesianos para a estimação dos parâmetros dado a exibilidade deste enfoque quando combinado ao uso dos métodos MCMC facilitados a partir do uso de softwares livres. Nesta tese e apresentado um estudo do poder empírico dos testes de hipóteses para os modelos univariados propostos bem como são introduzidos quatro exemplos, sendo os três primeiros voltados a aplicação da decisão de bioequivalência media e o quarto para a aplicação da bioequivalência populacional e individual. Nos três primeiros exemplos foram observados ganhos em termos de ajuste dos novos modelos propostos aos dados com relação ao modelo padrão segundo os critérios de seleção de modelos utilizados. O exemplo quatro apresenta uma analise padrão de bioequivalência populacional e individual com o código computacional para a obtenção dos resultados disponível no apêndice A bem como outros códigos para os demais exemplos. Embora a padroniza- ção das análises estatísticas para os estudos de bioequivalência seja importante, não deve-se esperar que um modelo padrão ajuste-se a qualquer conjunto de dados originados destes tipo de estudos. Neste sentido, são apresentados alternativas que podem auxiliar o pesquisador na tomada de uma decisão em termos de bioequivalência media mais segura. / The interest in bioequivalence studies began in the early 1960s especially in the United States of America where the FDA was the rst regulatory agency to show interest upon this issue. In Brazil, this interest started in 1999 the year when a law regulated the generic drugs in the country. The ANVISA is the Brazilian regulatory agency responsible for inspecting the bioequivalence centers and giving guidelines for this issue. In general, a standard parametric model for the statistical step is indicated for the average bioequivalence decision and this model is expected to be tted by the data obtained in the bioequivalence studies. In some cases, this model would not be appropriate. In this way, this thesis proposes the use of more comprehensive parametric models based on other probability distributions for the average bioequivalence decision and that can model asymmetrical data, a common situation in bioequivalence studies. In addition, there is no need of a logarithmic transformation for the pharmacokinetic parameters which could aect the range of the bioequivalence limits. We also propose the use of parametrical bivariate models for the joint decision of the average bioequivalence decision, since these measures are usually analyzed simultaneously with two pharmacokinetic parameters. We use Bayesian methods to estimate the parameters, given the great exibility of this approach when combined with the use of MCMC methods using free available softwares. This thesis also presents a study of the empirical power of hypothesis testing for the proposed univariate models and four examples are introduced. In the examples one, two and three we apply the average bioequivalence decision and in the fourth example we consider for the implementation of population and individual bioequivalence. In the examples one, two and three were observed gains in the tting of the proposed new models for the data where some existing approaches were used in the selection criteria for the proposed models. Example four provides a standard analysis of population and individual bioequivalence with the computer code for obtaining the results available in the Appendix A, as well as other codes. Although the standardization of statistical analysis for bioequivalence studies is important, a standard model is not expected to be well tted to any data set originated by such studies. In this way, we present alternatives that can help researchers in making a decision in terms of average bioequivalence with more security.
32

Bioequivalência de comprimidos de nimesulida do mercado nacional / Bioequivalence of nimesulide tablets of the internal market

Rolim, Clarice Madalena Bueno 09 May 2001 (has links)
A nimesulida, é um fármaco sintético, pouco solúvel em água (0,01 mg/mL), classificado como antiinflamatório não esteróide, com atividade analgésica e antipirética. No Brasil são comercializadas várias especialidades farmacêuticas orais, contendo nimesulida, na dosagem de 100 e 200 mg. Em termos de saúde pública tais produtos, prescritos pelo médico como similares intercambiáveis, deveriam apresentar, a mesma eficácia clínica, sendo a bioequivalência um requisito fundamental. Um estudo em que se verifique a qualidade biofarmacotécnica de uma amostragem destes produtos toma-se bastante útil para que se possa avaliar a situação atual. Pretendeu-se neste trabalho, realizar avaliação biofarmacotécnica in vitro (cinética da dissolução) e in vivo (bioequivalência) de formulações do mercado nacional contendo nimesulida, analisando a presença ou não de bioequivalência: Nisulid® 100 mg - (Laboratórios Asta Medica) considerado produto referência (R) e Sintalgim® 100 mg - (Laboratórios Sintofarma) considerado produto teste (T). Inicialmente desenvolveu-se método para análise da cinética de dissolução, pois não existe método de dissolução nos compêndios oficiais para comprimidos contendo nimesulida. Após padronização do método, avaliou-se a cinética de dissolução de três lotes R e três T de comprimidos de nimesulida através dos parâmetros ks (constante de velocidade de dissolução) e t50% (tempo necessário para dissolução 50% do fármaco presente na forma farmacêutica), oriundos dos perfis de dissolução. Obteve-se valores de ks de 0,1417 min-1; 0,1506 min-1 e 0,1138 min-1 para os três lotes de R e 0,2540 min-1, 0,1965 min-1, 0,1557 min-1 para os três lotes de T, e t50% entre 4,6 a 6,09 min para R e 2,73 a 4,45 min para T. O ensaio de bioequivalência foi do tipo quantitativo, direto, cruzado com distribuição aleatória, com coletas de amostras de sangue até doze horas após administração dos produtos R e T a vinte e quatro voluntários. Validou-se método por cromatografia líquida de alta eficiência para quantificação das amostras de plasma contendo nimesulida, avaliandose exatidão, precisão, recuperação, especificidade e linearidade. Utilizou-se fenacetina como padrão interno que mostrou-se sensível e reprodutível nas concentrações exigidas para o método, e detecção em ultravioleta a 230 nm, após extração com solvente orgânico. A bioequivalência foi determinada pela comparação dos parâmetrosfarmacocinéticos Cmax (concentração plasmática máxima) tmax (tempo necessário para Cmax) e AUCT (área sob a curva de decaimento plasmático) obtidos para R e T. Os resultados foram submetidos a análise estatística conforme recomendado pelo FDA-USA, determinando-se os intervalos de confiança 90% (I.C. 90%) para as relações entre Cmax e AUCT para R e T. Os valores médios destes parâmetros foram para R e T, respectivamente, 9,22 µg/mL e 9,41 µg/mL; 58,98 µgxh/mL e 58,52 µgxh/mL. Os I.C. 90% para Cmax e AUCT foram, respectivamente 96,73 a 101,44 % e 99,42 a 105,31%. Conclui-se que R e T são bioequivalentes, podendo ser administrados de forma intercambiável, sem prejuízo do efeito terapêutico. / The nimesulide (4-nitro-2-phenoxymethanosulphonanilide) is a non acidic nonsteroidal antinflammatory drug (NSAID). It is a sparingly water-soluble drug and exerts its pharmacological activity through various mechanisms of action. In Brazil are marked several oral pharmaceutical forms, with nimesulide dosage of 100 and 200 mg. The products should be, considered as an pharmaceutical alternative to other NSAIDs must be the same clinical efficacy and has confirmed the fundamental requirement, the bioequivalence. A study to establish the biopharmaceutical quality of the some batches of this products became interesting and useful to evaluate the actual situation. The present study was was designed to perform in vitro (dissolution kinetics) and in vivo (bioequivalence) biopharmaceutical evaluation of two commercial products available in Brazil: Nisulid® (Asta Medica) as the reference product (R) and Sintalgim® (Sintofarma) as the test product (T). There is no official method for nimesulide dosage form so initially a method was development and standardized for evaluation of dissolution kinetics of nimesulide tablets. Dissolution kinetics for samples from three batches of R an three of T was analysed through ks (dissolution rate constant) and t50% (time for dissolution of 50% ofthe drug in the dosage form), obtained from dissolution profiles. Results showed ks values of 0,1417 min-1; 0,1506 min-1 and 0,1138 min-1 for the three tested batches of R and 0,2540 min-1, 0,1965 min-1, 0,1557 min-1 for three batches of T, and t50% values between 4,6 and 6,09 min for R and 2,73 and 4,45 min para T. Bioequivalence assay was crossover and randomized. Blood samples were collected throughout a twelve hours period of administration of R and T to twenty four fasting volunteers. A simple, accurate, precise and sensitive high-performance liquid chromatographic (HPLC) method with internal standard which demonstrate sensitive and reproducible to, and ultraviolet detection at 230 nm, was developed and validated for quantification of nimesulide in plasma samples after liquid-liquid extraction. Bioequivalence was assessed through pharmacokinetic parameters Cmax (peak plasma concentration), tmax (time to reach Cmax) and AUCT (area under the plasma concentration vs time curve) for R and T. Results were submitted to statistical analysis according to the FDA-USA and 90% confidence intervals (90% C.I.) were calculated for R and T Cmax ratios and T and R AUCT ratios. Average Cmax and AUCT values for R and T were, respectively: 9,22 µg/mL and 9,41 µg/mL; 58,98 µgxh/mL and 58,52 µgxh/mL. 90% C.I. for Cmax and AUCT were respectively 96,73 - 101,44 % and 99,42 - 105,31%. Results show the R and T are bioequivalence and can be administered in an interchangeable way, without any prejudice of therapeutic effect.
33

Avaliação de bioquivalência de comprimidos contendo 100 mg de acetato de ciproterona / Bioequivalence evaluation of tablets containing 100 mg cyproterone acetate

Ching, Rute Chuang Kuei 07 November 2006 (has links)
O acetato de ciproterona é um esteróide sexual sintético com atividade antiandrogênica, antigonadotrópica e progestagênica. O objetivo deste estudo foi avaliar a bioequivalência de duas marcas comerciais de comprimidos contendo 100 mg de acetato de ciproterona em voluntários sadios. O ensaio foi do tipo quantitativo direto, com delineamento aleatório, cruzado e aberto, formando-se dois grupos de voluntários, A e B. Entre as fases houve um período de \"wash out\" de 27 dias, correspondente a, no mínimo, 10 vezes o valor de meia-vida de eliminação de acetato de ciproterona. Amostras de sangue foram coletadas em tubo heparinizado até 216 horas após a administração dos produtos. A bioequivalência dos produtos foi avaliada quantificando-se o fármaco em plasma, através de metodologia bioanalítica desenvolvida e previamente validada. As curvas médias de decaimento plasmático obtidas para os produtos teste (Androsteron® 100 mg - Bergamo, lote PI0004) e referência (Androcur® 100 mg Schering, lote 14616A) foram semelhantes, da mesma forma que as médias dos parâmetros farmacocinéticos Cmax (referência: 159,05 ng/mL; teste: 170,40 ng/mL), tmax (referência: 3,59 h; teste: 3,50 h) e ASC0-t (referência: 5563,03 ngxh/mL; teste: 5453,80 ngxh/mL) e ASC0-∞ (referência: 6266,22 ngxh/mL; teste: 6218,31 ngxh/mL). No presente estudo, a análise de variância (ANOVA) realizada para avaliação do efeito de produto, grupo e período em relação aos parâmetros farmacocinéticos avaliados demonstrou ausência destes efeitos em ASC0-t e ASC0-∞ para os valores calculados com todos os picos da curva plasmática. A ANOVA indicou ainda ausência de efeito de produto e período para Cmax, mas presença de efeito grupo para este parâmetro. Entretanto a constatação do efeito grupo não significa que as formulações avaliadas não sejam bioequivalentes, apenas que há uma diferença entre os grupos de indivíduos. Os valores do intervalo de confiança 90% para a razão de Cmax, (91,0 a 117,9%), ASC0-t (88,4 a 107,8%) e ASC0-∞. (90,6 a 107,8%) encontram-se entre 80 a 125 %, intervalo proposto pelo FDA e ANVISA. Desta forma, a avaliação dos resultados obtidos permite concluir que não houve diferença significativa entre as formulações teste e referência, ou seja, as duas formulações possuem biodisponibilidades estatisticamente equivalentes, em termos de velocidade e extensão da absorção. / Cyproterone acetate (6-chloro-1β,2βα-dihydro-17-hydroxy-3\'H-cyclopropa[1,2] pregna - 1,4,6-triene-3,20-dione acetate) (CPA) is a synthetic steroid with antiandrogenic and progestogenic properties. The aim of the present study was to evaluate the bioequivalence of two cyproterone acetate formulations. The bioequivalence of cyproterone acetate 100 mg tablets was determined in healthy volunteers after a single dose in a randomized crossover study, with a 27 days washout period between the doses. Reference (Androcur®) and test (Androsteron®) products were administered to twenty-four volunteers with 200 mL water after overnight fasting. Blood samples were taken up to 216 h post dose, the plasma was separated and the concentrations of cyproterone acetate were measured using a simple and rapid chromatographic method (HPLC). The pharmacokinetic parameters AUC0-t, AUC0-∞, Cmax, tmax and t(1/2)el were calculated for both formulations from plasma concentration time profiles. The calculated pharmacokinetic parameters were compared statistically to evaluate bioequivalence between the two brands and no significant differences between the two studied formulations were found. The 90% geometric confidence intervals of the mean ratio of In-transformed Cmax, AUC0-t and AUC0-∞ values were between 91,0 and 117,9% (Cmax), 88,4 and 107,8% (AUC0-t) ando 90,6 and 107,8% (AUC0-∞), and thus within the acceptance ranges, satisfying the bioequivalence criteria of the European Committee for Proprietary Medicinal Products and the US Food and Drug Administration Guidelines. In the Iight of the present study it can be concluded that the two evaluated cyproterone acetate formulations are bioequivalent in terms of the rate and extent of absorption.
34

Modelagem estatística em estudos de bioequivalência sob o enfoque Bayesiano / Statistical modeling in bioequivalence studies under Bayesian approach.

Roberto Molina de Souza 15 April 2015 (has links)
O interesse pelos estudos de bioequivalência iniciou-se na década de 60, sendo o FDA (EUA) a primeira agência reguladora a se interessar por esta questão. No Brasil, uma lei de 1999 regulamentou o medicamento genérico no país, sendo este um importante meio de acesso aos medicamentos pela população e fazendo parte da política de medicamentos do SUS. No Brasil, a ANVISA e responsável por inspecionar os centros de bioequivalência bem como dar as diretrizes para estes. Um modelo paramétrico padrão para a etapa estatística e disponibilizado para a decisão de bioequivalência media e espera-se que este ajuste-se aos dados obtidos nos estudos de bioequivalência, o que nem sempre acontece. Neste sentido, e proposto nesta tese o uso de modelos paramétricos mais abrangentes baseados em outras distribuições de probabilidade para a decisão de bioequivalência media e que possam modelar a assimetria dos dados, dispensando o uso da transformação logarítmica para os parâmetros farmacocinéticos o que afeta a amplitude dos limites de bioequivalência. Propõe-se também o uso de modelos bivariados para a tomada conjunta da decisão de bioequivalência media, quando são analisados simultaneamente dois parâmetros farmacocinéticos. Foram utilizados métodos Bayesianos para a estimação dos parâmetros dado a exibilidade deste enfoque quando combinado ao uso dos métodos MCMC facilitados a partir do uso de softwares livres. Nesta tese e apresentado um estudo do poder empírico dos testes de hipóteses para os modelos univariados propostos bem como são introduzidos quatro exemplos, sendo os três primeiros voltados a aplicação da decisão de bioequivalência media e o quarto para a aplicação da bioequivalência populacional e individual. Nos três primeiros exemplos foram observados ganhos em termos de ajuste dos novos modelos propostos aos dados com relação ao modelo padrão segundo os critérios de seleção de modelos utilizados. O exemplo quatro apresenta uma analise padrão de bioequivalência populacional e individual com o código computacional para a obtenção dos resultados disponível no apêndice A bem como outros códigos para os demais exemplos. Embora a padroniza- ção das análises estatísticas para os estudos de bioequivalência seja importante, não deve-se esperar que um modelo padrão ajuste-se a qualquer conjunto de dados originados destes tipo de estudos. Neste sentido, são apresentados alternativas que podem auxiliar o pesquisador na tomada de uma decisão em termos de bioequivalência media mais segura. / The interest in bioequivalence studies began in the early 1960s especially in the United States of America where the FDA was the rst regulatory agency to show interest upon this issue. In Brazil, this interest started in 1999 the year when a law regulated the generic drugs in the country. The ANVISA is the Brazilian regulatory agency responsible for inspecting the bioequivalence centers and giving guidelines for this issue. In general, a standard parametric model for the statistical step is indicated for the average bioequivalence decision and this model is expected to be tted by the data obtained in the bioequivalence studies. In some cases, this model would not be appropriate. In this way, this thesis proposes the use of more comprehensive parametric models based on other probability distributions for the average bioequivalence decision and that can model asymmetrical data, a common situation in bioequivalence studies. In addition, there is no need of a logarithmic transformation for the pharmacokinetic parameters which could aect the range of the bioequivalence limits. We also propose the use of parametrical bivariate models for the joint decision of the average bioequivalence decision, since these measures are usually analyzed simultaneously with two pharmacokinetic parameters. We use Bayesian methods to estimate the parameters, given the great exibility of this approach when combined with the use of MCMC methods using free available softwares. This thesis also presents a study of the empirical power of hypothesis testing for the proposed univariate models and four examples are introduced. In the examples one, two and three we apply the average bioequivalence decision and in the fourth example we consider for the implementation of population and individual bioequivalence. In the examples one, two and three were observed gains in the tting of the proposed new models for the data where some existing approaches were used in the selection criteria for the proposed models. Example four provides a standard analysis of population and individual bioequivalence with the computer code for obtaining the results available in the Appendix A, as well as other codes. Although the standardization of statistical analysis for bioequivalence studies is important, a standard model is not expected to be well tted to any data set originated by such studies. In this way, we present alternatives that can help researchers in making a decision in terms of average bioequivalence with more security.
35

Estudos da biodisponibilidade e bioequivalência de medicamentos com alimentação: fundamentos e critérios de execução / Bioavailability and bioequivalence studies of medicines with feeding: fundaments and execution criteria

Lima Filho, Pedro de 16 September 2005 (has links)
A biodisponibilidade é definida pelos parâmetros de velocidade e extensão com que o fármaco atinge a circulação sistêmica a partir da forma farmacêutica, sendo uma propriedade não somente do fármaco, mas também da formulação, representando o desempenho in vivo da qualidade do medicamento. O medicamento genérico, para ser intercambiável com sua referência (geralmente o inovador registrado após comprovação de eficácia e segurança), deve ser considerado pelas autoridades regulatórias como seu equivalente terapêutico. A bioequivalência é o estudo comparativo das biodisponibilidades entre medicamentos, empregado para comprovação de equivalência terapêutica, baseada no princípio de que a similaridade dos perfis sanguíneos de concentração-tempo proporciona similares resultados quanto à eficácia e segurança. O presente trabalho compreendeu uma abordagem sobre os estudos de biodisponibilidade e bioequivalência com alimentação, com objetivo de sistematização dos fundamentos científicos e critérios normativos nacionais e internacionais, avaliação da necessidade e elaboração de diretrizes para condução destes estudos. Foi pesquisada a literatura científica sobre o tema, com ênfase nas publicações dos últimos dez anos, e também as diretrizes regulatórias nacionais e internacionais vigentes. Foram avaliados os efeitos do alimento na absorção gastrintestinal de fármacos, os fatores envolvidos na interação fármaco-alimento e os mecanismos físico-químicos e fisiológicos envolvidos. O alimento pode influenciar a absorção dos fármacos e promover aumento, retardo ou redução de absorção, devido a diferentes efeitos, por exemplo: prolongamento do tempo de esvaziamento gástrico, interação direta do fármaco com constituintes do alimento, aumento da viscosidade do conteúdo intestinal, alteração do pH, aumento do fluxo sanguíneo esplâncnico e interação com transportadores. A interação fármaco-alimento pode resultar em alterações farmacocinéticas e farmacodinâmicas. O efeito do alimento é mais significativo nas fases de absorção e metabolismo do fármaco, podendo resultar em perda de eficácia ou toxicidade. As interações fármaco-alimento são influenciadas pela natureza do alimento, constituição e quantidade da refeição, tempo entre alimentação e medicação e pela formulação. A refeição altamente gordurosa tem maior potencial de alteração da fisiologia gastrintestinal, principalmente aumentando o tempo de esvaziamento gástrico, o fluxo sanguíneo e a secreção biliar. Esses efeitos podem afetar significativamente a absorção de fármacos, sendo especialmente críticos para as formulações de liberação modificada. O efeito total do alimento na farmacocinética é resultante da interação de múltiplos efeitos relacionados ao fármaco, à formulação, à fisiologia gastrintestinal e à refeição. Devido à variabilidade e difícil previsibilidade dos efeitos do alimento sobre a velocidade e extensão de absorção dos fármacos, devem ser conduzidos estudos de efeito do alimento para novos fármacos e novas formulações. A pesquisa resultou na compilação das diretrizes para avaliação do efeito do alimento na biodisponibilidade, incluindo-se os desenhos dos estudos. É apresentado um esquema para avaliação da necessidade dos estudos de biodisponibilidade e bioequivalência, com base nas características do fármaco e nos tipos de formulações. As diretrizes para requerimento e condução dos estudos foram sistematizadas em uma proposta de guia para estudos de biodisponibilidade e bioequivalência com alimentação a ser empregado no caso de registro e alterações pós-registro para medicamentos novos, genéricos e similares no Brasil. / Bioavailability is defined by rate and extension parameters with which the drug reaches the systemic circulation from its dosage form, being not only a property of such drug, but also of the formulation, representing the in vivo quality of the medicine. In order to be interchangeable with its reference drug (usually the innovative drug registered after efficacy and safety proof), the generic drug must be considered as its therapeutic equivalent. Bioequivalence is the comparative study between drugs\' bioavailabilities, used for the proving of therapeutic equivalence, based on the principle that the similarity between blood concentration-time profiles generates similar efficacy and safety results. This work is a discussion about the food-effect bioavailability and fed bioequivalence studies, aiming at systematizing the scientific fundaments and national and international regulatory criteria, necessity evaluation and elaboration of de guidelines for studies execution. Research was done on scientific literature on the subject, with emphasis on publications over the last ten years, and also on current regulatory guidelines. The effects of food on the gastrointestinal absorption of the drugs, the factors related to the food-drug interaction and the physical-chemical and physiological mechanisms involved were evaluated. Food may influence the drug absorption and cause drug absorption increase, delay or reduction due to different factors, for example: gastric emptying time increase, direct drug interaction with food constituents, intestinal content viscosity increase, pH alterations, spleen blood flow increase and transporter interaction. The food-drug interaction may cause pharmacokinectic and pharmacodynamics alterations. Food\'s effect is most significant during the absorption and metabolic phases of the drug and may result in efficacy loss or toxicity. The food-drug interaction is influenced by the nature of the food, meal constitution and quantity, feeding and medication interval time and formulation. A high-fat meal has greater gastrointestinal physiology alteration potential, especially increasing the gastric emptying time, the blood flow and bile secretion. These effects may significantly impact the drugs\' absorption being especially critical for the modified-release formulations. Toe total food effect on pharmacokinectic is the result of the interaction of multiple effects related to the drug, the formulation, the gastrointestinal physiology and the meal. Due to its variability and the difficulty to predict the effects of food on the rate and extension of drugs\' absorption effect studies must be carried out for new drugs and new formulations. The research resulted in the compilation of the guidelines for the evaluation of food effects on bioavailability, including the studies\' designs. A scheme is presented for the evaluation of the necessity of bioavailability and bioequivalence studies based on the drug\'s characteristics and the types of formulations. The guidelines for the requirement and conduction of the studies were systematized in a guide proposal for bioavailability and bioequivalence studies of medicines with feeding to be used in the case of registration, and post-registration changes for new, generic and similar drugs in Brazil.
36

Estudos da biodisponibilidade e bioequivalência de medicamentos com alimentação: fundamentos e critérios de execução / Bioavailability and bioequivalence studies of medicines with feeding: fundaments and execution criteria

Pedro de Lima Filho 16 September 2005 (has links)
A biodisponibilidade é definida pelos parâmetros de velocidade e extensão com que o fármaco atinge a circulação sistêmica a partir da forma farmacêutica, sendo uma propriedade não somente do fármaco, mas também da formulação, representando o desempenho in vivo da qualidade do medicamento. O medicamento genérico, para ser intercambiável com sua referência (geralmente o inovador registrado após comprovação de eficácia e segurança), deve ser considerado pelas autoridades regulatórias como seu equivalente terapêutico. A bioequivalência é o estudo comparativo das biodisponibilidades entre medicamentos, empregado para comprovação de equivalência terapêutica, baseada no princípio de que a similaridade dos perfis sanguíneos de concentração-tempo proporciona similares resultados quanto à eficácia e segurança. O presente trabalho compreendeu uma abordagem sobre os estudos de biodisponibilidade e bioequivalência com alimentação, com objetivo de sistematização dos fundamentos científicos e critérios normativos nacionais e internacionais, avaliação da necessidade e elaboração de diretrizes para condução destes estudos. Foi pesquisada a literatura científica sobre o tema, com ênfase nas publicações dos últimos dez anos, e também as diretrizes regulatórias nacionais e internacionais vigentes. Foram avaliados os efeitos do alimento na absorção gastrintestinal de fármacos, os fatores envolvidos na interação fármaco-alimento e os mecanismos físico-químicos e fisiológicos envolvidos. O alimento pode influenciar a absorção dos fármacos e promover aumento, retardo ou redução de absorção, devido a diferentes efeitos, por exemplo: prolongamento do tempo de esvaziamento gástrico, interação direta do fármaco com constituintes do alimento, aumento da viscosidade do conteúdo intestinal, alteração do pH, aumento do fluxo sanguíneo esplâncnico e interação com transportadores. A interação fármaco-alimento pode resultar em alterações farmacocinéticas e farmacodinâmicas. O efeito do alimento é mais significativo nas fases de absorção e metabolismo do fármaco, podendo resultar em perda de eficácia ou toxicidade. As interações fármaco-alimento são influenciadas pela natureza do alimento, constituição e quantidade da refeição, tempo entre alimentação e medicação e pela formulação. A refeição altamente gordurosa tem maior potencial de alteração da fisiologia gastrintestinal, principalmente aumentando o tempo de esvaziamento gástrico, o fluxo sanguíneo e a secreção biliar. Esses efeitos podem afetar significativamente a absorção de fármacos, sendo especialmente críticos para as formulações de liberação modificada. O efeito total do alimento na farmacocinética é resultante da interação de múltiplos efeitos relacionados ao fármaco, à formulação, à fisiologia gastrintestinal e à refeição. Devido à variabilidade e difícil previsibilidade dos efeitos do alimento sobre a velocidade e extensão de absorção dos fármacos, devem ser conduzidos estudos de efeito do alimento para novos fármacos e novas formulações. A pesquisa resultou na compilação das diretrizes para avaliação do efeito do alimento na biodisponibilidade, incluindo-se os desenhos dos estudos. É apresentado um esquema para avaliação da necessidade dos estudos de biodisponibilidade e bioequivalência, com base nas características do fármaco e nos tipos de formulações. As diretrizes para requerimento e condução dos estudos foram sistematizadas em uma proposta de guia para estudos de biodisponibilidade e bioequivalência com alimentação a ser empregado no caso de registro e alterações pós-registro para medicamentos novos, genéricos e similares no Brasil. / Bioavailability is defined by rate and extension parameters with which the drug reaches the systemic circulation from its dosage form, being not only a property of such drug, but also of the formulation, representing the in vivo quality of the medicine. In order to be interchangeable with its reference drug (usually the innovative drug registered after efficacy and safety proof), the generic drug must be considered as its therapeutic equivalent. Bioequivalence is the comparative study between drugs\' bioavailabilities, used for the proving of therapeutic equivalence, based on the principle that the similarity between blood concentration-time profiles generates similar efficacy and safety results. This work is a discussion about the food-effect bioavailability and fed bioequivalence studies, aiming at systematizing the scientific fundaments and national and international regulatory criteria, necessity evaluation and elaboration of de guidelines for studies execution. Research was done on scientific literature on the subject, with emphasis on publications over the last ten years, and also on current regulatory guidelines. The effects of food on the gastrointestinal absorption of the drugs, the factors related to the food-drug interaction and the physical-chemical and physiological mechanisms involved were evaluated. Food may influence the drug absorption and cause drug absorption increase, delay or reduction due to different factors, for example: gastric emptying time increase, direct drug interaction with food constituents, intestinal content viscosity increase, pH alterations, spleen blood flow increase and transporter interaction. The food-drug interaction may cause pharmacokinectic and pharmacodynamics alterations. Food\'s effect is most significant during the absorption and metabolic phases of the drug and may result in efficacy loss or toxicity. The food-drug interaction is influenced by the nature of the food, meal constitution and quantity, feeding and medication interval time and formulation. A high-fat meal has greater gastrointestinal physiology alteration potential, especially increasing the gastric emptying time, the blood flow and bile secretion. These effects may significantly impact the drugs\' absorption being especially critical for the modified-release formulations. Toe total food effect on pharmacokinectic is the result of the interaction of multiple effects related to the drug, the formulation, the gastrointestinal physiology and the meal. Due to its variability and the difficulty to predict the effects of food on the rate and extension of drugs\' absorption effect studies must be carried out for new drugs and new formulations. The research resulted in the compilation of the guidelines for the evaluation of food effects on bioavailability, including the studies\' designs. A scheme is presented for the evaluation of the necessity of bioavailability and bioequivalence studies based on the drug\'s characteristics and the types of formulations. The guidelines for the requirement and conduction of the studies were systematized in a guide proposal for bioavailability and bioequivalence studies of medicines with feeding to be used in the case of registration, and post-registration changes for new, generic and similar drugs in Brazil.
37

Aplicação de métodos quimiométricos em estudos de bioequivalência do antibiótico amoxicilina / Application of chemistry methods in bioequivalence studies of antibiotic amoxicillin

Ramos, Douglas Rodrigues 28 February 2008 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2018-07-19T10:53:48Z No. of bitstreams: 2 Dissertação - Douglas Rodrigues Ramos - 2008.pdf: 918271 bytes, checksum: 173c60fac328e79faa1800dee72b28b0 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-07-19T11:20:33Z (GMT) No. of bitstreams: 2 Dissertação - Douglas Rodrigues Ramos - 2008.pdf: 918271 bytes, checksum: 173c60fac328e79faa1800dee72b28b0 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-07-19T11:20:33Z (GMT). No. of bitstreams: 2 Dissertação - Douglas Rodrigues Ramos - 2008.pdf: 918271 bytes, checksum: 173c60fac328e79faa1800dee72b28b0 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2008-02-28 / The generic medicines have brought to the national population a higher possibility to access the treatment with medication, the competition stimulation and the medicine exchange insertion, in which the reference formulation can be substituted by the generic medicine, without any harm to the treatment. ANVISA (National Agency of Sanitary Surveillance) regulates this national market, demanding the bioequivalence confirmation between test and reference medicines. Therefore, in a period of six years, those studies have been performed and several generic medicines have been liberated to commercialization. However, the exchange confirmation among the several generic and reference medication are still difficult to observe due to the complexity of the values obtained. The chemometrics analysis decreases the sample space of the complex data which allows samples similarity observation as well as their classification in distinct groups. For that, Principal Components Analysis (PCA) and the Hierarchical Cluster Analysis (HCA) have been used. With these techniques an n-dimension space statistics have been evaluated for a bi-dimension of six amoxicillin bioequivalence studies as capsules and suspensions and therefore, classified them in groups in accordance with the similarity of the formulations pharmacokinetic profiles, which has allowed the medicine exchange observation. The chemometrics applications in pharmacokinetic data differentiated the pharmaceuticals forms capsule and suspensions, of absorption and elimination parameters allowing the exchange avaliations of formulations showing been useful in research laboratories or by regulatories agency for the quality monitoring of the medicine. / Os medicamentos genéricos trouxeram a polução nacional maior possibilidade de acesso ao tratamento medicamentoso, estímulos à concorrência e inserção da intercambialidade de medicamentos, onde a formulação referência pode ser substituída pelo medicamento genérico, sem prejuízos ao tratamento. A ANVISA (Agência Nacional de Vigilância Sanitária) regulamenta este mercado nacional exigindo a comprovação da bioequivalência entre os medicamentos teste e referência. Assim no período de seis anos, estudos foram realizados e vários medicamentos genéricos foram liberados para a comercialização. Entretanto, a comprovação da intercambialidade entre os vários medicamentos genéricos e medicamentos referências ainda são de difíceis observações devido à complexidade dos dados obtidos. A análise quimiométrica reduz o espaço amostral de dados complexos possibilitando a observação da similaridade das amostras bem como a classificação das mesmas em grupos distintos. Para tal utilizou técnicas de Análise Componentes Principais (PCA) e a Análise Hierárquica de Agrupamentos (HCA). Com estas técnicas foram avaliados seis estudos bioequivalentes de Amoxicilina nas formas de cápsulas e suspensões, e posteriormente, classificados em grupos de acordo com a similaridade dos perfis farmacocinéticos destas formulações. A aplicação da quimiometria em dados de farmacocinéticos diferenciou as formas farmacêuticas cápsula e suspensão, os parâmetros de absorção e eliminação possibilitando a avaliação da intercambialidade das formulações demonstrando ser úteis em laboratórios de pesquisas ou por agências reguladoras para o monitoramento da qualidade de medicamentos.
38

Bioequivalência tópica de produtos contendo metronidazol através da dermatofarmacocinética (DPK)

ARAUJO, Thalita Pedon de 26 February 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-08-22T12:37:56Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Thalita Pedon de Araujo.pdf: 2526779 bytes, checksum: a40c82344a005b431aae114c685b4df6 (MD5) / Made available in DSpace on 2016-08-22T12:37:56Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Thalita Pedon de Araujo.pdf: 2526779 bytes, checksum: a40c82344a005b431aae114c685b4df6 (MD5) Previous issue date: 2016-02-26 / CAPEs / A bioequivalência de três formulações de metronidazol (MTZ) 0,75% sendo uma delas disponível no Brasil, Rozex® (Galderma, Brasil, produto de referência) e duas formulações geleificadas (Teste 01 e Teste 02) desenvolvidas em nosso laboratório contendo os mesmos excipientes do produto referência foram avaliadas por meio de um estudo aberto, randomizado, de dois períodos e cruzado, realizado em 14 voluntários brasileiros saudáveis. Uma dose única de 143,5 mg de formulação tópica foi aplicada em duplicata em cada braço do voluntário e o estrato córneo foi coletado em período de 6 e 12 horas após a aplicação correspondente ao tempo de absorção e eliminação respectivamente. O perfil de concentração do metronidazol (MTZ) no estrato córneo (EC) após a aplicação foi determinado pela remoção sequencial das camadas de EC utilizando fita adesiva (Scotch Tape Livro, 3M, St. Paul, MN). Cada local de aplicação foi tratado com 30 fitas. Todas as fitas foram pesadas antes e depois do procedimento de tape stripping em balança (Sartorius®) para posterior cálculo da quantidade de EC extraída. Após o procedimento de extração do fármaco das fitas as concentrações do MTZ no estrato córneo foram determinadas utilizando cromatografia líquida de alta eficiência – CLAE e a avaliação dos dados foi realizada de duas diferentes formas seja considerando ou não o volume de estrato córneo coletado. A análise da bioequivalência tópica in vivo dos produtos contendo metronidazol através da dermatofarmacocinética (DPK) demonstrou com confiança de 95% no intervalo de 80% - 125% que o produto Teste 01 é bioequivalente ao produto de referência Rozex e que o produto Teste 02 é bioinequivalente ao produto de referência Rozex, considerando ou não a quantidade de estrato córneo coletado. Conclui-se assim que, apenas 0,5% a mais de agente espessante no Teste 2 foi suficiente para aumentar a viscosidade em 1,4 vezes e para diminuir a espalhabilidade em 3 vezes deste produto, levando a uma não-bioequivalência entre o teste 2 e o produto de referência que continham os mesmos constituintes. Resultado que demostra a necessidade de mudança na legislação brasileira atual. / The bioequivalence of three formulations of metronidazole (MTZ) 0.75% being one available in Brazil, Rozex® (Galderma, Brazil, reference product) and two formulations (Test 01 and Test 02) developed in our laboratory, containing the same excipients reference product were evaluated using an open, randomized, two-period, crossover healthy Brazilian performed in 14 volunteers. A single dose of 143.5 mg of topical formulation was applied in duplicate on each of the volunteer arm and the stratum corneum was collected in a period of 6 and 12 hours after the application corresponding to the time of absorption and elimination, respectively. The concentration profile of metronidazole (MTZ) in the stratum corneum (SC) after application was determined by sequential removal of the EC layers using adhesive tape (Scotch Book Tape, 3M, St. Paul, MN). Each application site was treated with 30 tapes. All tapes were weighed before and after the tape stripping procedure on scale (Sartorius®) for subsequent calculation of the amount of EC extracted. After the drug extraction procedure ribbons concentrations of MTZ in the stratum corneum have been determined using high-performance liquid chromatography - HPLC and data evaluation was done in two ways considering whether or not the volume of the stratum corneum collected. The analysis of topical bioequivalence in vivo products containing metronidazole by dermatofarmacocinética (DPK) has shown with 95% confidence in the 80% range - 125% that the product test 01 is bioequivalent to Rozex reference product and that the product test 02 is bioinequivalente Rozex the reference product, considering or not the amount of stratum corneum collected. It is therefore concluded that only 0.5% more thickener in Test 2 was sufficient to increase the viscosity by 1.4 times and to reduce the spreadability of this product 3 times, leading to a non-bioequivalence between the test 2 and the reference product containing the same constituents. A result that demonstrates the need for change in the current Brazilian legislation.
39

Bioequivalência de comprimidos de nimesulida do mercado nacional / Bioequivalence of nimesulide tablets of the internal market

Clarice Madalena Bueno Rolim 09 May 2001 (has links)
A nimesulida, é um fármaco sintético, pouco solúvel em água (0,01 mg/mL), classificado como antiinflamatório não esteróide, com atividade analgésica e antipirética. No Brasil são comercializadas várias especialidades farmacêuticas orais, contendo nimesulida, na dosagem de 100 e 200 mg. Em termos de saúde pública tais produtos, prescritos pelo médico como similares intercambiáveis, deveriam apresentar, a mesma eficácia clínica, sendo a bioequivalência um requisito fundamental. Um estudo em que se verifique a qualidade biofarmacotécnica de uma amostragem destes produtos toma-se bastante útil para que se possa avaliar a situação atual. Pretendeu-se neste trabalho, realizar avaliação biofarmacotécnica in vitro (cinética da dissolução) e in vivo (bioequivalência) de formulações do mercado nacional contendo nimesulida, analisando a presença ou não de bioequivalência: Nisulid® 100 mg - (Laboratórios Asta Medica) considerado produto referência (R) e Sintalgim® 100 mg - (Laboratórios Sintofarma) considerado produto teste (T). Inicialmente desenvolveu-se método para análise da cinética de dissolução, pois não existe método de dissolução nos compêndios oficiais para comprimidos contendo nimesulida. Após padronização do método, avaliou-se a cinética de dissolução de três lotes R e três T de comprimidos de nimesulida através dos parâmetros ks (constante de velocidade de dissolução) e t50% (tempo necessário para dissolução 50% do fármaco presente na forma farmacêutica), oriundos dos perfis de dissolução. Obteve-se valores de ks de 0,1417 min-1; 0,1506 min-1 e 0,1138 min-1 para os três lotes de R e 0,2540 min-1, 0,1965 min-1, 0,1557 min-1 para os três lotes de T, e t50% entre 4,6 a 6,09 min para R e 2,73 a 4,45 min para T. O ensaio de bioequivalência foi do tipo quantitativo, direto, cruzado com distribuição aleatória, com coletas de amostras de sangue até doze horas após administração dos produtos R e T a vinte e quatro voluntários. Validou-se método por cromatografia líquida de alta eficiência para quantificação das amostras de plasma contendo nimesulida, avaliandose exatidão, precisão, recuperação, especificidade e linearidade. Utilizou-se fenacetina como padrão interno que mostrou-se sensível e reprodutível nas concentrações exigidas para o método, e detecção em ultravioleta a 230 nm, após extração com solvente orgânico. A bioequivalência foi determinada pela comparação dos parâmetrosfarmacocinéticos Cmax (concentração plasmática máxima) tmax (tempo necessário para Cmax) e AUCT (área sob a curva de decaimento plasmático) obtidos para R e T. Os resultados foram submetidos a análise estatística conforme recomendado pelo FDA-USA, determinando-se os intervalos de confiança 90% (I.C. 90%) para as relações entre Cmax e AUCT para R e T. Os valores médios destes parâmetros foram para R e T, respectivamente, 9,22 µg/mL e 9,41 µg/mL; 58,98 µgxh/mL e 58,52 µgxh/mL. Os I.C. 90% para Cmax e AUCT foram, respectivamente 96,73 a 101,44 % e 99,42 a 105,31%. Conclui-se que R e T são bioequivalentes, podendo ser administrados de forma intercambiável, sem prejuízo do efeito terapêutico. / The nimesulide (4-nitro-2-phenoxymethanosulphonanilide) is a non acidic nonsteroidal antinflammatory drug (NSAID). It is a sparingly water-soluble drug and exerts its pharmacological activity through various mechanisms of action. In Brazil are marked several oral pharmaceutical forms, with nimesulide dosage of 100 and 200 mg. The products should be, considered as an pharmaceutical alternative to other NSAIDs must be the same clinical efficacy and has confirmed the fundamental requirement, the bioequivalence. A study to establish the biopharmaceutical quality of the some batches of this products became interesting and useful to evaluate the actual situation. The present study was was designed to perform in vitro (dissolution kinetics) and in vivo (bioequivalence) biopharmaceutical evaluation of two commercial products available in Brazil: Nisulid® (Asta Medica) as the reference product (R) and Sintalgim® (Sintofarma) as the test product (T). There is no official method for nimesulide dosage form so initially a method was development and standardized for evaluation of dissolution kinetics of nimesulide tablets. Dissolution kinetics for samples from three batches of R an three of T was analysed through ks (dissolution rate constant) and t50% (time for dissolution of 50% ofthe drug in the dosage form), obtained from dissolution profiles. Results showed ks values of 0,1417 min-1; 0,1506 min-1 and 0,1138 min-1 for the three tested batches of R and 0,2540 min-1, 0,1965 min-1, 0,1557 min-1 for three batches of T, and t50% values between 4,6 and 6,09 min for R and 2,73 and 4,45 min para T. Bioequivalence assay was crossover and randomized. Blood samples were collected throughout a twelve hours period of administration of R and T to twenty four fasting volunteers. A simple, accurate, precise and sensitive high-performance liquid chromatographic (HPLC) method with internal standard which demonstrate sensitive and reproducible to, and ultraviolet detection at 230 nm, was developed and validated for quantification of nimesulide in plasma samples after liquid-liquid extraction. Bioequivalence was assessed through pharmacokinetic parameters Cmax (peak plasma concentration), tmax (time to reach Cmax) and AUCT (area under the plasma concentration vs time curve) for R and T. Results were submitted to statistical analysis according to the FDA-USA and 90% confidence intervals (90% C.I.) were calculated for R and T Cmax ratios and T and R AUCT ratios. Average Cmax and AUCT values for R and T were, respectively: 9,22 µg/mL and 9,41 µg/mL; 58,98 µgxh/mL and 58,52 µgxh/mL. 90% C.I. for Cmax and AUCT were respectively 96,73 - 101,44 % and 99,42 - 105,31%. Results show the R and T are bioequivalence and can be administered in an interchangeable way, without any prejudice of therapeutic effect.
40

Avaliação de bioquivalência de comprimidos contendo 100 mg de acetato de ciproterona / Bioequivalence evaluation of tablets containing 100 mg cyproterone acetate

Rute Chuang Kuei Ching 07 November 2006 (has links)
O acetato de ciproterona é um esteróide sexual sintético com atividade antiandrogênica, antigonadotrópica e progestagênica. O objetivo deste estudo foi avaliar a bioequivalência de duas marcas comerciais de comprimidos contendo 100 mg de acetato de ciproterona em voluntários sadios. O ensaio foi do tipo quantitativo direto, com delineamento aleatório, cruzado e aberto, formando-se dois grupos de voluntários, A e B. Entre as fases houve um período de \"wash out\" de 27 dias, correspondente a, no mínimo, 10 vezes o valor de meia-vida de eliminação de acetato de ciproterona. Amostras de sangue foram coletadas em tubo heparinizado até 216 horas após a administração dos produtos. A bioequivalência dos produtos foi avaliada quantificando-se o fármaco em plasma, através de metodologia bioanalítica desenvolvida e previamente validada. As curvas médias de decaimento plasmático obtidas para os produtos teste (Androsteron® 100 mg - Bergamo, lote PI0004) e referência (Androcur® 100 mg Schering, lote 14616A) foram semelhantes, da mesma forma que as médias dos parâmetros farmacocinéticos Cmax (referência: 159,05 ng/mL; teste: 170,40 ng/mL), tmax (referência: 3,59 h; teste: 3,50 h) e ASC0-t (referência: 5563,03 ngxh/mL; teste: 5453,80 ngxh/mL) e ASC0-∞ (referência: 6266,22 ngxh/mL; teste: 6218,31 ngxh/mL). No presente estudo, a análise de variância (ANOVA) realizada para avaliação do efeito de produto, grupo e período em relação aos parâmetros farmacocinéticos avaliados demonstrou ausência destes efeitos em ASC0-t e ASC0-∞ para os valores calculados com todos os picos da curva plasmática. A ANOVA indicou ainda ausência de efeito de produto e período para Cmax, mas presença de efeito grupo para este parâmetro. Entretanto a constatação do efeito grupo não significa que as formulações avaliadas não sejam bioequivalentes, apenas que há uma diferença entre os grupos de indivíduos. Os valores do intervalo de confiança 90% para a razão de Cmax, (91,0 a 117,9%), ASC0-t (88,4 a 107,8%) e ASC0-∞. (90,6 a 107,8%) encontram-se entre 80 a 125 %, intervalo proposto pelo FDA e ANVISA. Desta forma, a avaliação dos resultados obtidos permite concluir que não houve diferença significativa entre as formulações teste e referência, ou seja, as duas formulações possuem biodisponibilidades estatisticamente equivalentes, em termos de velocidade e extensão da absorção. / Cyproterone acetate (6-chloro-1β,2βα-dihydro-17-hydroxy-3\'H-cyclopropa[1,2] pregna - 1,4,6-triene-3,20-dione acetate) (CPA) is a synthetic steroid with antiandrogenic and progestogenic properties. The aim of the present study was to evaluate the bioequivalence of two cyproterone acetate formulations. The bioequivalence of cyproterone acetate 100 mg tablets was determined in healthy volunteers after a single dose in a randomized crossover study, with a 27 days washout period between the doses. Reference (Androcur®) and test (Androsteron®) products were administered to twenty-four volunteers with 200 mL water after overnight fasting. Blood samples were taken up to 216 h post dose, the plasma was separated and the concentrations of cyproterone acetate were measured using a simple and rapid chromatographic method (HPLC). The pharmacokinetic parameters AUC0-t, AUC0-∞, Cmax, tmax and t(1/2)el were calculated for both formulations from plasma concentration time profiles. The calculated pharmacokinetic parameters were compared statistically to evaluate bioequivalence between the two brands and no significant differences between the two studied formulations were found. The 90% geometric confidence intervals of the mean ratio of In-transformed Cmax, AUC0-t and AUC0-∞ values were between 91,0 and 117,9% (Cmax), 88,4 and 107,8% (AUC0-t) ando 90,6 and 107,8% (AUC0-∞), and thus within the acceptance ranges, satisfying the bioequivalence criteria of the European Committee for Proprietary Medicinal Products and the US Food and Drug Administration Guidelines. In the Iight of the present study it can be concluded that the two evaluated cyproterone acetate formulations are bioequivalent in terms of the rate and extent of absorption.

Page generated in 0.0353 seconds