• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 1
  • Tagged with
  • 50
  • 41
  • 17
  • 15
  • 15
  • 12
  • 11
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fatores que afetam a bioequivalência e metanálise aplicada a intercambialidade de medicamentos

SOUZA FILHO, José Homero de 12 August 2016 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-03T21:06:44Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Homero de Souza Filho.pdf: 3360206 bytes, checksum: b14d659f58290fe7c32d09e315c11c19 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-09T20:51:16Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Homero de Souza Filho.pdf: 3360206 bytes, checksum: b14d659f58290fe7c32d09e315c11c19 (MD5) / Made available in DSpace on 2018-08-09T20:51:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Homero de Souza Filho.pdf: 3360206 bytes, checksum: b14d659f58290fe7c32d09e315c11c19 (MD5) Previous issue date: 2016-08-12 / CNPq / Estudos não garantem a bioequivalência entre genéricos ou entre similares do mesmo medicamento de referência. A grande alternância de fabricante de medicamento ao longo do tratamento, está gerando preocupação dos médicos e farmacêuticos, principalmente nos países desenvolvidos, pois os estudos, atualmente, realizados e exigidos pelas agências reguladoras não garantem que essas trocas sejam seguras e que não comprometam o tratamento do paciente. Este trabalho teve o objetivo de analisar as variáveis referentes ao impacto do cronograma de coleta, do gênero da população do estudo e dos critérios de escolha dos voluntários, parâmetros farmacocinéticos, coeficientes de variação no resultado dos estudos. Adicionalmente, foi avaliado e utilizado o método estatístico de metanálise para verificação da bioequivalência entre medicamentos genéricos e/ou similares em estudos independentes. A análise do impacto do cronograma de coleta foi realizada através da análise estatística da bioequivalência do estudo com diferentes cronogramas de coleta. O estudo do gênero foi conduzido com a realização de estudo com homens e mulheres em um único grupo e depois os grupos foram separados e comparados de forma isolada. A influência da massa corporal foi estudada separando os voluntários em subgrupos, de acordo com os critérios de massa corporal e índice de massa corporal. Já a metanálise foi realizada de acordo com um protocolo previamente elaborado, onde se avaliou a bioequivalência entre diversos fabricantes dos seguintes fármacos: metildopa, lamivudina, fluconazol, da associação de sulfametoxazol e trimetoprima. As analises mostraram que um cronograma com maior quantidade de pontos gera resultados mais fidedignos, além de propiciar uma redução do coeficiente de variação e um intervalo de confiança mais estreito. As mulheres apresentaram um tempo para concentração plasmática máxima - Tmáx maior e uma meia vida plasmática e um coeficiente de variação intersujeito menor que os homens. A seleção dos voluntários com a utilização de massa corporal como critério de seleção promoveu uma redução dos coeficientes de variação. A metanálise se mostrou uma técnica eficaz e que alguns medicamentos não foram considerados bioequivalentes. Concluímos que todos os fatores analisados podem afetar os valores dos parâmetros farmacocinéticos e alterar, inclusive, o resultado do estudo, todavia, o grau do impacto varia para cada medicamento e não podemos generalizar os resultados obtidos. A metanálise pode ser utilizada para avaliar medicamentos genéricos e similares em estudos independentes, aumentando a segurança para população e reduzindo os riscos nas trocas de medicamentos, produzidos por diferentes fabricantes. / Studies do not guarantee the equivalence between generic or between similar of the same reference drug. The big alternating manufacturer of medicine throughout the treatment, is generating concern of doctors and pharmacists, especially in developed countries, because the studies currently undertaken and required by regulatory agencies do not guarantee that these exchanges are safe and that do not compromise the patient's treatment. This work had the objective of analyzing the variables concerning the impact of the collection schedule, the genre of the population of the study and the criteria of choice of the volunteers, pharmacokinetic parameters, coefficients of variation in the outcome of the studies. Additionally, was evaluated and used the method of statistical meta-analysis for verification of equivalence between generic drugs and/or similar in independent studies. The analysis of the impact of the collection schedule was held through the statistical analysis of the bioequivalence study with different collection schedules. The genre study was conducted with the study with women and men in one group and then the groups were separated and compared in isolation. The influence of body weight was studied by separating the volunteers into subgroups according to the criteria of body weight and body mass index. Already the meta-analysis was performed according to a previously developed Protocol, where he assessed the equivalence between various manufacturers of the following drugs: methyldopa, lamivudine, fluconazole, the Association of sulfamethoxazole and trimethoprim. The analysis showed that a timeline with the most amount of points generates more reliable results, in addition to providing for a reduction in the coefficient of variation and a narrower confidence interval. Women showed a time to maximum plasma concentration-greater Tmáx and a plasma half-life and a coefficient of variation intersujeito less than men. The selection of the volunteers with the use of body mass as selection criteria promoted a reduction of the coefficient of variation (CV). The meta-analysis proved an effective technique and some medicines were not considered Bioequivalent. We conclude that all the factors analyzed can affect the values of the pharmacokinetic parameters and change, including the result of the study, however, the degree of impact varies for each medicine and we cannot generalize the results. The meta-analysis can be used to assess generic medicines and the like in independent studies, increasing security for population and reducing risk in the trade in medicines, produced by different manufacturers.
2

Avaliação da qualidade biofarmacêutica da ampicilina sob as formas de suspensão e cápsulas: ensaios in vitro e in vivo (bioequivalência) / Biopharmaceutical evaluation of ampicillin in capsules and suspensions: \"in vitro\" and \"in vivo\" studies (bioequivalence)

Consiglieri, Vladi Olga 18 December 1996 (has links)
A avaliação biofarmacêutica de formas farmacêuticas contendo ampicilina foi realizada em dois lotes de cápsulas e dois de suspensão oral. O estudo da bioequivalência seguiu delineamento experimental cruzado, com dois períodos, empregando 16 voluntários de ambos os sexos (7 homens e 9 mulheres), com idades entre 21 e 26 anos (média de 23 anos) e peso entre 48 e 105 Kg (média de 68,2 Kg), dentro do intervalo de 10 % do peso ideal. Exames clínicos e laboratoriais foram realizados para selecionar os voluntários, sendo excluídos aqueles que apresentaram alguma alteração nos parâmetros clínicos normais ou com histório de reação alérgica às penicilinas e, ainda, os indivíduos que estivessem fazendo uso de medicamentos a menos de uma semana da realização do estudo. O protocolo experimental foi aprovado previamente pela Comissão de Ética do Hospital Universitário (HUUSP). Os ensaios de bioequivalência foram efetuados em períodos distintos para cada forma farmacêutica, com uma semana de intervalo. No dia dos testes e após jejum de 12 horas, os voluntários foram divididos em dois grupos com igual número de indivíduos, sendo que, a cada grupo foi administrada dose única de 500 mg de ampicilina de lotes diferentes. Após período de wash out de 48 horas, a administração dos produtos aos grupos foi invertida para que todos os indivíduos recebessem ambos os produtos. A determinação quantitativa da ampicilina foi realizada em amostras de urina coletadas num período de doze horas, aplicando o método espectrofotométrico, com leituras a 320 nrn, após reação a 70° C em solução tampão fosfato/sulfato de cobre por 30 minutos. Os parâmetros farmacocinéticos calculados foram: quantidade acumulada de ampicilina na urina (Xuacumul), velocidade máxima de excreção urinária (Vmáx), tempo no qual essa velocidade foi atingida (tmáx), constantes de velocidade de eliminação (K) e de excreção urinária (ku)e a meia-vida de eliminação (t1/2). A recuperação de ampicilina inalterada na urina variou de 54,5 a 58,9 % e de 54,6 a 57,8 % das doses administradas para cápsulas e suspensão, respectivamente; a meia-vida média calculada foi de 1,9 h para cápsulas e de 1,7 h para suspensão. Os intervalos de confiança (α= 0,10) calculados para a razão das médias das quantidades acumuladas de ampicilina estão contidos no limite de 80 a120 %. A análise estatística dos resultados aplicando métodos paramétrico (ANOVA) e não paramétrico (Mann-Whitney), conforme as normas preconizadas pelo FDA, comprovou que não há diferenças significativas (nível de significância de 90 %) entre os produtos A e B quanto aos parâmetros estudados. / A biopharmaceutic quality evaluation of two brands of ampicillin capsule and suspension dosage forms is presented. The bioequivalence study was based on an open randomized two-period crossover design with 7 male and 9 female healthy volunteers, aged 21 to 26 years (mean 23 yr) with body weights ranging from 48 to 105 Kg (mean 68,2 Kg) and within 10 % of the ideal body weight. All subjects passed by routine clinical and laboratory examinations. The volunteers had no histories of alergic reaction to penicillins and no other drugs were taken for at least 1 week before starting the study. The clinical protocol was approved by the Ethics Committee ofthe University Hospital (HUUSP). Studies were conducted separately for each dosage form after 1 week interval. On the day of the study, following an overnight fast, subjects were divided into two groups, each receiving 500 mg single dose of one of the two ampicillin dosage form. After a 2-day washout period, the same products were given in inversed order. Ampicillin data were obtained from urine samples collected over a 12 hour period. A spectrophotometric measurement at 320 nm after reaction in copper-phosphate/sulfate buffer solution at 70°C for 30 minutes was used. Total cummulative urinary excretion (Xuacumul), urinary excretion rates (Vmax), time to peak (tmax), urinary excretion rate constants (ku), elimination rate constants (K), and elimination half lives (t1/22) were calculated. Mean urine unchanged ampicillin recoveries of administered doses ranged from 54,5 to 58,9 % for capsules and from 54,6 to 57,8% for suspensions; t1/2 ranged from 1,7 to 1,9 h. Confidence intervals (α=0,10) for average rates were within 80-120 %. Statistic parametric (ANOVA) analysis and non-parametric analysis (Mann-Whitney) showed non-significance differences on the studied parameters of the two products at 90% significance leveI, according to FDA regulations.
3

Avaliação biofarmacêutica in vitro e in vivo (bioequivalência) de comprimidos de ampicilina 500 mg comercializados no Brasil / In vitro and in vivo biopharmaceutical evalution (bioquivalence) of ampicillin 500mg tablets marketed in Brazil

Ferraz, Humberto Gomes 19 December 1997 (has links)
A ampicilina é um antibiótico semi-sintético, derivado da penicilina, que exibe amplo espectro de ação, sendo largamente comercializada no Brasil, onde são encontrados cerca de doze produtos sob a forma de comprimidos. O presente trabalho teve como propósito avaliar, do ponto de vista biofarmacêutico, quatro marcas comerciais (A, B, C e D) de comprimidos de ampicilina 500 mg, sendo que, para um dos laboratórios foram analisados dois lotes diferentes (AI e A2). Foram executadas análises físicas e físico-químicas in vitro (aspecto, variação de peso, diâmetro, espessura e dureza, friabilidade, tempo de desagregação, teste e perfil de dissolução e teor de ampicilina), com a finalidade de detectar-se possíveis falhas em relação a formulação e/ou tecnologia utilizada na fabricação dos produtos. Executou-se, também, um estudo de bioequivalência entre as formulações A2 e B, a fim de se verificar se ambas podem ser consideradas intercambiáveis. Para tanto, realizou-se um estudo cruzado aleatório em dois períodos, utilizando-se dezesseis voluntários sadios, sendo o fármaco quantificado na urina pelo método espectrofotométrico descrito inicialmente por SMITH et al. (1967). Os parâmetros farmacocinéticos avaliados foram a quantidade total de ampicilina excretada na urina (Du∞) e a velocidade máxima de excreção [(dDu/dt)max]. Os resultados das análises físicas e físico-químicas indicaram que o produto A1 apresentou diversas falhas, sendo estas constatadas, também, para C e D. Ao contrário, A2 e B não registraram qualquer discrepância. Na avaliação da bioequivalência entre as formulações A2 e B, obteve-se um intervalo de confiança de 93 a 110% para Du∞ e 91 a 132% para (dDu/dt)max. De acordo com as normas internacionalmente aceitas é possível concluir que as formulações podem ser consideradas bioequivalentes e, portanto, intercambiáveis. / Ampicillin is a semi-synthetic penicillin-derived antibiotic that has a broad action spectrum. In Brazil, where it is largely marketed, about twelve different tablets brands can be found. The aim of the present work was to evaluate from the biopharmaceutic point of view four ampicillin 500mg-tablet brands (A, B, C and D). Two different A-brand lots (AI and A2) were analyzed. Physical and in vitro physical-chemical analysis (aspect, weight variation, diameter, thickness and hardness, friability, disintegration time, dissolution test and profile and ampicillin content) were carried out in order to detect possible manufacturing failures as to formulation and/or technology used. A bioequivalence study between A2 and B was also carried out in order to check if both of them could be interchangeable. For such an aleatory two-period cross-over study was done by quantifying through spectrophotometry (SMITH et al., 1967) the content of ampicillin in sixteen healthy volunteers\'urine. The total ampicillin amount excreted in urine (Du∞) and maximum rate of excretion [(dDu/dt)max] were taken as pharmacokinetics parameters. The physical and physical-chemical analyses results indicated critical failures in A1 brand. Similarly several failures were also detected in C and D. Brands A2 and B instead showed no discrepancies. Confidence intervals of 93 to 110% for Du∞ and 91 to 132% for (dDu/dt)max, were found through bioequivalence evaluation between A2 and B formulations. According to international accepted standards both the fomulations can be considered bioequivalent, therefore interchangeable.
4

Avaliação biofarmacotécnica do Efavirenz um fármaco classe II (SCB)

César Galindo Bedor, Danilo 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T16:28:40Z (GMT). No. of bitstreams: 2 arquivo8500_1.pdf: 6996774 bytes, checksum: 9d8a367e8a4cc60f5267ffac2b59fb20 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A síndrome da imunodeficiência adquirida (AIDS) é a manifestação da infecção pelo vírus da imunodeficiência humana (HIV) que leva, em média, oito anos para o seu aparecimento. O tratamento da AIDS conta com diferentes classes de medicamentos que atuam em fases distintas do ciclo de replicação. O efavirenz (EFV), inibidor não nucleosídico da transcriptase reversa, é o primeiro fármaco anti- HIV aprovado para utilização uma vez ao dia, devido a sua alta meia vida. O efavirenz é um produto descrito fisicamente com pelo menos 5 (cinco) diferentes polimorfos e de classificação biofarmacêutica II. O presente estudo teve o objetivo de realizar ensaios de caracterização do pó, em seu estado sólido, de três diferentes lotes de insumo farmacêutico ativo, ensaios de solubilidade e dissolução intrínseca além de avaliar perfil de dissolução como ferramentas de Quality by Design e estudar a biodisponibilidade comparada entre um medicamento teste e o de referência. A caracterização físico-química foi realizada através de ensaios de potência, ensaios em nível molecular, análises em nível de partículas e análise da solubilidade e dissolução em meios clássicos e biorrelevantes. A bioequivalência foi realizada através de estudo aberto, aleatório e cruzado 2 x 2 com washout de 15 (quinze) dias. A caracterização mostrou resultados com semelhança em nível molecular, variação na potência, similaridade em nível de partículas e desvios em nível de aglomerado de partículas que levou às diferenças encontradas nos resultados de solubilidade e velocidade de dissolução. O estudo de equivalência farmacêutica e de perfis de dissolução utilizando aparato 4 e meios biorrelevantes não foram discriminantes o suficiente para prever as diferenças encontradas no ensaio de bioequivalência. Desta forma é imperativo que a qualidade de insumos farmacêuticos ativos do EFV seja avaliada de forma ampla, visando a garantia da segurança e eficácia do tratamento de pessoas infectadas pelo HIV, para isso devese realizar ensaios além dos descritos nas farmacopéias. O presente estudo mostrou a importância da inclusão de dados científicos, Quality by Design, no desenvolvimento de produtos farmacêuticos a base de fármacos de classe II caso do EFV
5

Avaliação biofarmacêutica in vitro e in vivo (bioequivalência) de comprimidos de ampicilina 500 mg comercializados no Brasil / In vitro and in vivo biopharmaceutical evalution (bioquivalence) of ampicillin 500mg tablets marketed in Brazil

Humberto Gomes Ferraz 19 December 1997 (has links)
A ampicilina é um antibiótico semi-sintético, derivado da penicilina, que exibe amplo espectro de ação, sendo largamente comercializada no Brasil, onde são encontrados cerca de doze produtos sob a forma de comprimidos. O presente trabalho teve como propósito avaliar, do ponto de vista biofarmacêutico, quatro marcas comerciais (A, B, C e D) de comprimidos de ampicilina 500 mg, sendo que, para um dos laboratórios foram analisados dois lotes diferentes (AI e A2). Foram executadas análises físicas e físico-químicas in vitro (aspecto, variação de peso, diâmetro, espessura e dureza, friabilidade, tempo de desagregação, teste e perfil de dissolução e teor de ampicilina), com a finalidade de detectar-se possíveis falhas em relação a formulação e/ou tecnologia utilizada na fabricação dos produtos. Executou-se, também, um estudo de bioequivalência entre as formulações A2 e B, a fim de se verificar se ambas podem ser consideradas intercambiáveis. Para tanto, realizou-se um estudo cruzado aleatório em dois períodos, utilizando-se dezesseis voluntários sadios, sendo o fármaco quantificado na urina pelo método espectrofotométrico descrito inicialmente por SMITH et al. (1967). Os parâmetros farmacocinéticos avaliados foram a quantidade total de ampicilina excretada na urina (Du∞) e a velocidade máxima de excreção [(dDu/dt)max]. Os resultados das análises físicas e físico-químicas indicaram que o produto A1 apresentou diversas falhas, sendo estas constatadas, também, para C e D. Ao contrário, A2 e B não registraram qualquer discrepância. Na avaliação da bioequivalência entre as formulações A2 e B, obteve-se um intervalo de confiança de 93 a 110% para Du∞ e 91 a 132% para (dDu/dt)max. De acordo com as normas internacionalmente aceitas é possível concluir que as formulações podem ser consideradas bioequivalentes e, portanto, intercambiáveis. / Ampicillin is a semi-synthetic penicillin-derived antibiotic that has a broad action spectrum. In Brazil, where it is largely marketed, about twelve different tablets brands can be found. The aim of the present work was to evaluate from the biopharmaceutic point of view four ampicillin 500mg-tablet brands (A, B, C and D). Two different A-brand lots (AI and A2) were analyzed. Physical and in vitro physical-chemical analysis (aspect, weight variation, diameter, thickness and hardness, friability, disintegration time, dissolution test and profile and ampicillin content) were carried out in order to detect possible manufacturing failures as to formulation and/or technology used. A bioequivalence study between A2 and B was also carried out in order to check if both of them could be interchangeable. For such an aleatory two-period cross-over study was done by quantifying through spectrophotometry (SMITH et al., 1967) the content of ampicillin in sixteen healthy volunteers\'urine. The total ampicillin amount excreted in urine (Du∞) and maximum rate of excretion [(dDu/dt)max] were taken as pharmacokinetics parameters. The physical and physical-chemical analyses results indicated critical failures in A1 brand. Similarly several failures were also detected in C and D. Brands A2 and B instead showed no discrepancies. Confidence intervals of 93 to 110% for Du∞ and 91 to 132% for (dDu/dt)max, were found through bioequivalence evaluation between A2 and B formulations. According to international accepted standards both the fomulations can be considered bioequivalent, therefore interchangeable.
6

Avaliação da qualidade biofarmacêutica da ampicilina sob as formas de suspensão e cápsulas: ensaios in vitro e in vivo (bioequivalência) / Biopharmaceutical evaluation of ampicillin in capsules and suspensions: \"in vitro\" and \"in vivo\" studies (bioequivalence)

Vladi Olga Consiglieri 18 December 1996 (has links)
A avaliação biofarmacêutica de formas farmacêuticas contendo ampicilina foi realizada em dois lotes de cápsulas e dois de suspensão oral. O estudo da bioequivalência seguiu delineamento experimental cruzado, com dois períodos, empregando 16 voluntários de ambos os sexos (7 homens e 9 mulheres), com idades entre 21 e 26 anos (média de 23 anos) e peso entre 48 e 105 Kg (média de 68,2 Kg), dentro do intervalo de 10 % do peso ideal. Exames clínicos e laboratoriais foram realizados para selecionar os voluntários, sendo excluídos aqueles que apresentaram alguma alteração nos parâmetros clínicos normais ou com histório de reação alérgica às penicilinas e, ainda, os indivíduos que estivessem fazendo uso de medicamentos a menos de uma semana da realização do estudo. O protocolo experimental foi aprovado previamente pela Comissão de Ética do Hospital Universitário (HUUSP). Os ensaios de bioequivalência foram efetuados em períodos distintos para cada forma farmacêutica, com uma semana de intervalo. No dia dos testes e após jejum de 12 horas, os voluntários foram divididos em dois grupos com igual número de indivíduos, sendo que, a cada grupo foi administrada dose única de 500 mg de ampicilina de lotes diferentes. Após período de wash out de 48 horas, a administração dos produtos aos grupos foi invertida para que todos os indivíduos recebessem ambos os produtos. A determinação quantitativa da ampicilina foi realizada em amostras de urina coletadas num período de doze horas, aplicando o método espectrofotométrico, com leituras a 320 nrn, após reação a 70° C em solução tampão fosfato/sulfato de cobre por 30 minutos. Os parâmetros farmacocinéticos calculados foram: quantidade acumulada de ampicilina na urina (Xuacumul), velocidade máxima de excreção urinária (Vmáx), tempo no qual essa velocidade foi atingida (tmáx), constantes de velocidade de eliminação (K) e de excreção urinária (ku)e a meia-vida de eliminação (t1/2). A recuperação de ampicilina inalterada na urina variou de 54,5 a 58,9 % e de 54,6 a 57,8 % das doses administradas para cápsulas e suspensão, respectivamente; a meia-vida média calculada foi de 1,9 h para cápsulas e de 1,7 h para suspensão. Os intervalos de confiança (α= 0,10) calculados para a razão das médias das quantidades acumuladas de ampicilina estão contidos no limite de 80 a120 %. A análise estatística dos resultados aplicando métodos paramétrico (ANOVA) e não paramétrico (Mann-Whitney), conforme as normas preconizadas pelo FDA, comprovou que não há diferenças significativas (nível de significância de 90 %) entre os produtos A e B quanto aos parâmetros estudados. / A biopharmaceutic quality evaluation of two brands of ampicillin capsule and suspension dosage forms is presented. The bioequivalence study was based on an open randomized two-period crossover design with 7 male and 9 female healthy volunteers, aged 21 to 26 years (mean 23 yr) with body weights ranging from 48 to 105 Kg (mean 68,2 Kg) and within 10 % of the ideal body weight. All subjects passed by routine clinical and laboratory examinations. The volunteers had no histories of alergic reaction to penicillins and no other drugs were taken for at least 1 week before starting the study. The clinical protocol was approved by the Ethics Committee ofthe University Hospital (HUUSP). Studies were conducted separately for each dosage form after 1 week interval. On the day of the study, following an overnight fast, subjects were divided into two groups, each receiving 500 mg single dose of one of the two ampicillin dosage form. After a 2-day washout period, the same products were given in inversed order. Ampicillin data were obtained from urine samples collected over a 12 hour period. A spectrophotometric measurement at 320 nm after reaction in copper-phosphate/sulfate buffer solution at 70°C for 30 minutes was used. Total cummulative urinary excretion (Xuacumul), urinary excretion rates (Vmax), time to peak (tmax), urinary excretion rate constants (ku), elimination rate constants (K), and elimination half lives (t1/22) were calculated. Mean urine unchanged ampicillin recoveries of administered doses ranged from 54,5 to 58,9 % for capsules and from 54,6 to 57,8% for suspensions; t1/2 ranged from 1,7 to 1,9 h. Confidence intervals (α=0,10) for average rates were within 80-120 %. Statistic parametric (ANOVA) analysis and non-parametric analysis (Mann-Whitney) showed non-significance differences on the studied parameters of the two products at 90% significance leveI, according to FDA regulations.
7

Avaliação da bioequivalência de formulações do mercado nacional contendo fluconazol / Evaluation of the bioequivalence of capsules containing 150 mg of fluconazole

Porta, Valentina 19 November 1999 (has links)
O fluconazol é um fármaco antifúngico utilizado na prevenção e tratamento de infecções micóticas. Atualmente, no mercado brasileiro, vários laboratórios farmacêuticos comercializam produtos a base de fluconazol na forma de cápsulas de 150 mg. Estes produtos são considerados similares e, portanto, teoricamente intercambiáveis, por conterem o mesmo princípio ativo nas mesmas dosagem e forma farmacêutica. No entanto, não existem estudos atestando a bioequivalência entre eles. Pretendeu-se, nesse trabalho, realizar avaliação biofarmacotécnica in vitro (cinética de dissolução) e in vivo (bioequivalência) de duas formulações do mercado nacional contendo fluconazol: Zoltec® 150 mg (laboratórios Pfizer Ltda.), considerado produto referência (R) e Flunazol® 150 mg (Laboratórios Sintofarma S.A.), considerado produto teste (T). Inicialmente, desenvolveu-se método para a análise da cinética de dissolução, já que não existe teste oficial de dissolução para formas farmacêuticas contendo fluconazol. Após padronização do método, avaliou-se a cinética de dissolução de cápsulas de fluconazol provenientes de dois lotes de R e dois lotes de T por meio dos parâmetros ks (constante de velocidade de dissolução) e t85% (tempo necessário para dissolução de 85% do fármaco presente na forma farmacêutica), derivados dos perfis de dissolução. Obteve-se ks de 0,1079 min-1 e 0,1377 min-1 para os dois lotes de R testados e 0,5421 min-1 para os dosi lotes de T, e t85% entre 15,09 min e 20,06 min para R e entre 5,64 min e 6,02 min para T. O ensaio de bioequivalência foi do tipo aleatório cruzado, com coleta de amostras de sangue até 96 horas após administração dos produtos R e T a 28 voluntários em jejum. Para quantificação do fluconazol em amostras de plasma desenvolveu-se e validou-se método simples, exato, preciso e sensível por cromatografia líqüida de alta eficiência (CLAE) sem utilização de padrão interno, e detecção em ultravioleta a 210 nm, após extração com solvente orgânico em meio básico. A bioequivalência entre os produtos foi determinada através da comparação dos parâmetros farmacocinéticos Cmax (concentração plasmática máxima), tmax (tempo necessário para Cmax) e AUCT (área sob a curva de decaimento plasmático) obtidos para R e T. Os resultados foram submetidos a análise estatística conforme recomendado pelo FDA-USA, determinando-se os intervalos de confiança 90% (I.C. 90%) para as relações entre Cmax de T e R e AUCT de T e R. Os valores médios de Cmax, tmax e AUCT para R e T foram, respectivamente: 3,64 mg/L e 3,75 mg/L; 2,96 h e 2,79 h; 153,33 mgh/L e 154,45 mgh/L. Os I.C. 90% para Cmax e AUCT foram, respectivamente, 101,06% a 105,45% e 97,96% a 103,36%. Concluiu-se que R e T são bioequivalentes, podendo ser administrados de forma intercambiável, sem prejuízo do efeito terapêutico. / Fluconazole is an antifungal agent widely used in the prevention and treatment of invasive fungal infections. Many brazilian pharmaceutical industries manufacture capsules containing 150 mg of fluconazole. As such products contain the same amount of the same therapeutically active ingredient in the same dosage form, they are considered to be interchangeable, indeed no bioequivalence study have been conducted to assess this. The present study was designed to perform in vitro (dissolution kinetics) and in vivo (bioequivalence) biopharmaceutical evaluation of two commercial products available in Brazil: Zoltec® 150 mg (Pfizer) as the reference product (R) and Flunazol® 150 mg (Sintofarma) as the test product (T). There is no official dissolution method for fluconazole dosage forms so initially a methos was developed and standardized for the evaluation of dissolution kinetics of fluconazole capsules. Dissolution kinetics for samples from two batches of R and two batches of T was analysed through ks (dissolution rate constant) and t85% (time for dissolution of 85% of the drug in the dosage form), obtained from dissolution profiles. Results showed ks values of 0,1079 min-1 and 0,1377 min-1 for the two tested batches of R and 0,5421 min-1 for both tested batches of T, and t85% values between 15,09 min and 20,06 min for R and between 5,64 min and 6,02 min for T. Bioequivalence assay was crossover and randomized. Blood samples were collected throughout a 96 hours period after administration of R and T to 28 fasting volunteers. A simple, accurate, precise and sensitive high-performance liquid chromatographic (HPLC) method without internal standard, and ultraviolet detection at 210 nm, was developed and validated for quantification of fluconazole im plasma samples after liquid-liquid extraction. Bioequivalence was assessed through pharmacokinetic parameters Cmax (peak plasma concentration), tmax (time to reach Cmax) and AUCT (área under the “plasma concentration vs time" curve) for R and T. Results were submitted to statistical analysis according to the FDA-USA and 90% confidence intervals (90% C.I.) were calculated for T and R Cmax ratios and T and R AUCT ratios. Average Cmax, tmax and AUCT values for R and T were, respectively: 3,64 mg/L and 3,75 mg/L; 2,96 h and 2,79 h; 153,33 mgh/L and 154,45 mgh/L. 90% C.I. for Cmax and AUCT were, respectively, 101,06% - 105,45% and 97,96% - 103,36%. Results show that R and T are bioequivalent and can be administered in an interchangeable way, without any prejudice of therapeutic effect.
8

Avaliação da bioequivalência de formulações do mercado nacional contendo fluconazol / Evaluation of the bioequivalence of capsules containing 150 mg of fluconazole

Valentina Porta 19 November 1999 (has links)
O fluconazol é um fármaco antifúngico utilizado na prevenção e tratamento de infecções micóticas. Atualmente, no mercado brasileiro, vários laboratórios farmacêuticos comercializam produtos a base de fluconazol na forma de cápsulas de 150 mg. Estes produtos são considerados similares e, portanto, teoricamente intercambiáveis, por conterem o mesmo princípio ativo nas mesmas dosagem e forma farmacêutica. No entanto, não existem estudos atestando a bioequivalência entre eles. Pretendeu-se, nesse trabalho, realizar avaliação biofarmacotécnica in vitro (cinética de dissolução) e in vivo (bioequivalência) de duas formulações do mercado nacional contendo fluconazol: Zoltec® 150 mg (laboratórios Pfizer Ltda.), considerado produto referência (R) e Flunazol® 150 mg (Laboratórios Sintofarma S.A.), considerado produto teste (T). Inicialmente, desenvolveu-se método para a análise da cinética de dissolução, já que não existe teste oficial de dissolução para formas farmacêuticas contendo fluconazol. Após padronização do método, avaliou-se a cinética de dissolução de cápsulas de fluconazol provenientes de dois lotes de R e dois lotes de T por meio dos parâmetros ks (constante de velocidade de dissolução) e t85% (tempo necessário para dissolução de 85% do fármaco presente na forma farmacêutica), derivados dos perfis de dissolução. Obteve-se ks de 0,1079 min-1 e 0,1377 min-1 para os dois lotes de R testados e 0,5421 min-1 para os dosi lotes de T, e t85% entre 15,09 min e 20,06 min para R e entre 5,64 min e 6,02 min para T. O ensaio de bioequivalência foi do tipo aleatório cruzado, com coleta de amostras de sangue até 96 horas após administração dos produtos R e T a 28 voluntários em jejum. Para quantificação do fluconazol em amostras de plasma desenvolveu-se e validou-se método simples, exato, preciso e sensível por cromatografia líqüida de alta eficiência (CLAE) sem utilização de padrão interno, e detecção em ultravioleta a 210 nm, após extração com solvente orgânico em meio básico. A bioequivalência entre os produtos foi determinada através da comparação dos parâmetros farmacocinéticos Cmax (concentração plasmática máxima), tmax (tempo necessário para Cmax) e AUCT (área sob a curva de decaimento plasmático) obtidos para R e T. Os resultados foram submetidos a análise estatística conforme recomendado pelo FDA-USA, determinando-se os intervalos de confiança 90% (I.C. 90%) para as relações entre Cmax de T e R e AUCT de T e R. Os valores médios de Cmax, tmax e AUCT para R e T foram, respectivamente: 3,64 mg/L e 3,75 mg/L; 2,96 h e 2,79 h; 153,33 mgh/L e 154,45 mgh/L. Os I.C. 90% para Cmax e AUCT foram, respectivamente, 101,06% a 105,45% e 97,96% a 103,36%. Concluiu-se que R e T são bioequivalentes, podendo ser administrados de forma intercambiável, sem prejuízo do efeito terapêutico. / Fluconazole is an antifungal agent widely used in the prevention and treatment of invasive fungal infections. Many brazilian pharmaceutical industries manufacture capsules containing 150 mg of fluconazole. As such products contain the same amount of the same therapeutically active ingredient in the same dosage form, they are considered to be interchangeable, indeed no bioequivalence study have been conducted to assess this. The present study was designed to perform in vitro (dissolution kinetics) and in vivo (bioequivalence) biopharmaceutical evaluation of two commercial products available in Brazil: Zoltec® 150 mg (Pfizer) as the reference product (R) and Flunazol® 150 mg (Sintofarma) as the test product (T). There is no official dissolution method for fluconazole dosage forms so initially a methos was developed and standardized for the evaluation of dissolution kinetics of fluconazole capsules. Dissolution kinetics for samples from two batches of R and two batches of T was analysed through ks (dissolution rate constant) and t85% (time for dissolution of 85% of the drug in the dosage form), obtained from dissolution profiles. Results showed ks values of 0,1079 min-1 and 0,1377 min-1 for the two tested batches of R and 0,5421 min-1 for both tested batches of T, and t85% values between 15,09 min and 20,06 min for R and between 5,64 min and 6,02 min for T. Bioequivalence assay was crossover and randomized. Blood samples were collected throughout a 96 hours period after administration of R and T to 28 fasting volunteers. A simple, accurate, precise and sensitive high-performance liquid chromatographic (HPLC) method without internal standard, and ultraviolet detection at 210 nm, was developed and validated for quantification of fluconazole im plasma samples after liquid-liquid extraction. Bioequivalence was assessed through pharmacokinetic parameters Cmax (peak plasma concentration), tmax (time to reach Cmax) and AUCT (área under the “plasma concentration vs time” curve) for R and T. Results were submitted to statistical analysis according to the FDA-USA and 90% confidence intervals (90% C.I.) were calculated for T and R Cmax ratios and T and R AUCT ratios. Average Cmax, tmax and AUCT values for R and T were, respectively: 3,64 mg/L and 3,75 mg/L; 2,96 h and 2,79 h; 153,33 mgh/L and 154,45 mgh/L. 90% C.I. for Cmax and AUCT were, respectively, 101,06% - 105,45% and 97,96% - 103,36%. Results show that R and T are bioequivalent and can be administered in an interchangeable way, without any prejudice of therapeutic effect.
9

Avaliação da influência dos fatores fisiológicos nos estudos de bioequivalência

Homero de Souza Filho, José 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T16:26:08Z (GMT). No. of bitstreams: 2 arquivo1150_1.pdf: 2999574 bytes, checksum: 7b286b19ebd3856d9386cd8f56b53716 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Como atesta a Organização Mundial da Saúde em sua carta de princípios, os programas de medicamentos genéricos têm sido reconhecidos como uma alternativa para melhorar o acesso aos medicamentos tanto nos países em desenvolvimento como nos países industrializados . No entanto, somente em 1999, com a Lei nº 9.787, foi instituído no Brasil o medicamento genérico, regulamentado pela Resolução nº 391, de agosto de 1999. Esta resolução já sofreu algumas atualizações e por último, no dia 02 de março de 2007 foi publicado a RDC 16, que se encontra atualmente em vigor. Na realização de um estudo de bioequivalência são comparados os perfis farmacocinéticos de dois medicamentos sob condições padronizadas de alimentação, horário, estresse, sono, etc. Estas condições não são padronizadas na administração terapêutica do medicamento, podendo ocorrer diferentes interações, como por exemplo, uma interação entre o excipiente de um medicamento genérico com um alimento, dificultando sua dissolução e conseqüentemente sua absorção e biodisponibilidade. Estas e outras condições não são avaliadas na realização de um estudo padrão de bioequivalência / biodisponibilidade relativa. Com o intuito de avaliar a influência de algumas destas condições nos ensaios de bioequivalência, os estudos aqui apresentados mostram a influência da alimentação e dos gêneros dos voluntários nos parâmetros farmacocinéticos, Cmax, Tmax e ASC em estudos realizados com venlafaxina 75 mg e lamivudina de 150 mg, respectivamente. Concluiu-se que a alimentação aumentou a biodisponibilidade da venlafaxina, e esta elevação foi mais significativa no medicamento de referência, contrariando as informações encontradas na literatura para este fármaco. Já no estudo realizado com a lamivudina não foi encontrada diferença significativa nos parâmetros farmacocinéticos entre os gêneros, no entanto obteve-se um maior coeficiente de variação inter-indivíduo no gênero feminino
10

Desenvolvimento e validação de métodos bioanalíticos para quantificação de hidroclorotiazida e cimetidina em plasma humano e aplicação em estudos da farmacocinética comparada

Eduardo Miranda de Sousa, Carlos 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T16:27:22Z (GMT). No. of bitstreams: 2 arquivo2084_1.pdf: 1052849 bytes, checksum: 5755ac115807355b687973e612634a6e (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / A adoção da Política nacional de Medicamentos Genéricos pelo Governo Federal (Lei n° 9.787 de 10 de fevereiro de 1999) envolve a produção de medicamentos de melhor qualidade, mais seguros e eficazes, comprovados através da realização de testes de equivalência farmacêutica e bioequivalência, contribuindo para aumento do acesso aos medicamentos e fortalecendo a indústria nacional através do desenvolvimento tecnológico. Para isto, é necessário o desenvolvimento e a validação de metodologias analíticas capazes de determinar o fármaco em fluidos biológicos. No Brasil, ainda existe uma carência de recursos humanos qualificados para atender a crescente demanda do mercado. Como colaborador da implementação da política nacional de Medicamentos Genéricos, este trabalho tem por objetivo o desenvolvimento e validação de métodos bioanalíticos para aplicação em estudos de biodisponibilidade relativa de dois fármacos (cimetidina e hidroclorotiazida) em voluntários sadios. Aplicou-se a técnica de extração liquido-liquido para purificação das amostras e para quantificação foi utilizada a cromatografia líquida de alta eficiência com detecção por espectrometria de massas em tandem (CL-EM/EM). Após o desenvolvimento, validação e aplicação das metodologias; os resultados dos parâmetros farmacocinéticos foram obtidos através das curvas de concentração sangüínea do fármaco versus tempo, e analisados estatisticamente para determinação da bioequivalência. Os seguintes parâmetros farmacocinéticos devem ser determinados: ASC, Cmax e Tmax. Os métodos demonstraram-se econômicos, práticos, rápidos, sensíveis, precisos e exatos segundo as normas da ANVISA e da FDA. Portanto, os estudos apresentaram ferramentas adequadas para avaliação das formulações de cimetidina comprimido (teste e referência) e das formulações de hidroclorotiazida comprimido (teste e referência), ambas mostraram-se bioequivalentes

Page generated in 0.0548 seconds