• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fatores que afetam a bioequivalência e metanálise aplicada a intercambialidade de medicamentos

SOUZA FILHO, José Homero de 12 August 2016 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-03T21:06:44Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Homero de Souza Filho.pdf: 3360206 bytes, checksum: b14d659f58290fe7c32d09e315c11c19 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-09T20:51:16Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Homero de Souza Filho.pdf: 3360206 bytes, checksum: b14d659f58290fe7c32d09e315c11c19 (MD5) / Made available in DSpace on 2018-08-09T20:51:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE José Homero de Souza Filho.pdf: 3360206 bytes, checksum: b14d659f58290fe7c32d09e315c11c19 (MD5) Previous issue date: 2016-08-12 / CNPq / Estudos não garantem a bioequivalência entre genéricos ou entre similares do mesmo medicamento de referência. A grande alternância de fabricante de medicamento ao longo do tratamento, está gerando preocupação dos médicos e farmacêuticos, principalmente nos países desenvolvidos, pois os estudos, atualmente, realizados e exigidos pelas agências reguladoras não garantem que essas trocas sejam seguras e que não comprometam o tratamento do paciente. Este trabalho teve o objetivo de analisar as variáveis referentes ao impacto do cronograma de coleta, do gênero da população do estudo e dos critérios de escolha dos voluntários, parâmetros farmacocinéticos, coeficientes de variação no resultado dos estudos. Adicionalmente, foi avaliado e utilizado o método estatístico de metanálise para verificação da bioequivalência entre medicamentos genéricos e/ou similares em estudos independentes. A análise do impacto do cronograma de coleta foi realizada através da análise estatística da bioequivalência do estudo com diferentes cronogramas de coleta. O estudo do gênero foi conduzido com a realização de estudo com homens e mulheres em um único grupo e depois os grupos foram separados e comparados de forma isolada. A influência da massa corporal foi estudada separando os voluntários em subgrupos, de acordo com os critérios de massa corporal e índice de massa corporal. Já a metanálise foi realizada de acordo com um protocolo previamente elaborado, onde se avaliou a bioequivalência entre diversos fabricantes dos seguintes fármacos: metildopa, lamivudina, fluconazol, da associação de sulfametoxazol e trimetoprima. As analises mostraram que um cronograma com maior quantidade de pontos gera resultados mais fidedignos, além de propiciar uma redução do coeficiente de variação e um intervalo de confiança mais estreito. As mulheres apresentaram um tempo para concentração plasmática máxima - Tmáx maior e uma meia vida plasmática e um coeficiente de variação intersujeito menor que os homens. A seleção dos voluntários com a utilização de massa corporal como critério de seleção promoveu uma redução dos coeficientes de variação. A metanálise se mostrou uma técnica eficaz e que alguns medicamentos não foram considerados bioequivalentes. Concluímos que todos os fatores analisados podem afetar os valores dos parâmetros farmacocinéticos e alterar, inclusive, o resultado do estudo, todavia, o grau do impacto varia para cada medicamento e não podemos generalizar os resultados obtidos. A metanálise pode ser utilizada para avaliar medicamentos genéricos e similares em estudos independentes, aumentando a segurança para população e reduzindo os riscos nas trocas de medicamentos, produzidos por diferentes fabricantes. / Studies do not guarantee the equivalence between generic or between similar of the same reference drug. The big alternating manufacturer of medicine throughout the treatment, is generating concern of doctors and pharmacists, especially in developed countries, because the studies currently undertaken and required by regulatory agencies do not guarantee that these exchanges are safe and that do not compromise the patient's treatment. This work had the objective of analyzing the variables concerning the impact of the collection schedule, the genre of the population of the study and the criteria of choice of the volunteers, pharmacokinetic parameters, coefficients of variation in the outcome of the studies. Additionally, was evaluated and used the method of statistical meta-analysis for verification of equivalence between generic drugs and/or similar in independent studies. The analysis of the impact of the collection schedule was held through the statistical analysis of the bioequivalence study with different collection schedules. The genre study was conducted with the study with women and men in one group and then the groups were separated and compared in isolation. The influence of body weight was studied by separating the volunteers into subgroups according to the criteria of body weight and body mass index. Already the meta-analysis was performed according to a previously developed Protocol, where he assessed the equivalence between various manufacturers of the following drugs: methyldopa, lamivudine, fluconazole, the Association of sulfamethoxazole and trimethoprim. The analysis showed that a timeline with the most amount of points generates more reliable results, in addition to providing for a reduction in the coefficient of variation and a narrower confidence interval. Women showed a time to maximum plasma concentration-greater Tmáx and a plasma half-life and a coefficient of variation intersujeito less than men. The selection of the volunteers with the use of body mass as selection criteria promoted a reduction of the coefficient of variation (CV). The meta-analysis proved an effective technique and some medicines were not considered Bioequivalent. We conclude that all the factors analyzed can affect the values of the pharmacokinetic parameters and change, including the result of the study, however, the degree of impact varies for each medicine and we cannot generalize the results. The meta-analysis can be used to assess generic medicines and the like in independent studies, increasing security for population and reducing risk in the trade in medicines, produced by different manufacturers.
2

A intercambialidade entre equivalentes terapêuticos da lamotrigina: avaliação clínica e laboratorial dos pacientes portadores de epilepsia refratária / Interchangeability between therapeutic equivalents of lamotrigine: clinical and laboratory evaluation of patients with refractory epilepsy

Girolineto, Beatriz Maria Pereira 27 November 2009 (has links)
A epilepsia é uma patologia caracterizada como sinal ou sintoma de uma desordem neurológica que se manifesta por breves descargas de neurotransmissores neuronais, decorrentes de distúrbios nas funções elétricas cerebrais levando a ocorrência de crises. Entre os medicamentos disponíveis no mercado, a lamotrigina (LTG) tem sido amplamente utilizada, principalmente devido a sua maior tolerabilidade e menor índice de interação farmacológica com outros fármacos antiepilépticos (DAEs). A maioria dos DAEs, e particularmente os mais novos, são de elevado custo financeiro para o paciente, portanto o sistema de saúde oferece aos seus usuários a possibilidade os receberem, porém, uma mesma regional de saúde pode variar o fornecimento de um princípio ativo entre os seus equivalentes terapêuticos disponíveis no mercado. Assim sendo, esse estudo tem a finalidade de avaliar as conseqüências clínicas e laboratoriais relacionadas à utilização de diferentes equivalentes terapêuticos da LTG (referência e similares). O estudo foi dividido em três períodos de 42 dias cada, um para cada formulação onde se realizaram atendimentos médico e farmacêutico e foram coletados dados sobre a freqüência de crises, a ocorrência de eventos adversos, dosagem plasmática de LTG e qualidade de vida dos nove pacientes incluídos no estudo. As formulações A e B são medicamentos similares e a C é o medicamento referência. Com relação ao número médio de crises foi de 3,22; 7,17 e 5,75 para as formulações A, B e C, respectivamente, no entanto essa diferença não é estatisticamente significante. Também não houve diferença significativa entre as concentrações plasmáticas de LTG. Com relação à ocorrência de reações adversas houve três casos com a formulação C e nenhum com as demais, com significância estatística (p<0,05). Quanto a qualidade de vida não houve uma diferença significativa quando se comparou todas as formulações entretanto a formulação A aumentou significativamente a qualidade de vida dos pacientes durante de sua utilização. Assim sendo, concluí-se que os medicamentos similares apresentaram resultados satisfatórios quando comparado ao medicamento de referência, entretanto a substituição das formulações pode dificultar o controle das crises epilépticas e ao manejo da epilepsia. / Epilepsy is a condition characterized as a sign or a symptom of a neurological disorder manifested by brief discharges of neuronal neurotransmitters, resulting from disturbances in electrical brain fuctions leading to crises. Among the drugs available to patients, lamotrigine (LTG) has been widely used, mainly due to their greater tolerability and lower rate of drug interactions with other antiepileptic drugs (AEDs). Most of the AEDs, and particularly the newest, have high cost to patient, so the health system offers to users the possibility to receive then, but, the same regional health can change the supply of a drug within available therapeutic equivalents in the market. Thus, this study aims to evaluate the clinical and laboratory consequences related to use of different therapeutic equivalents of LTG (reference and similar drugs). The study was divided into three periods of 42 days, one for each formulation which held medical and pharmaceutical care, and data about the frequency of seizures, the occurrence of adverse effects, measurement of plasma LTG and quality of life were collected. The formulations A and B are similar drugs and C is the reference drug. Regarding the average number of seizures it was 3.22, 7.17 and 5.75 for formulations A, B and C, respectively, however, this difference is not statistically significant. There was no significant difference between plasma concentrations of LTG. Also, regarding the occurrence of adverse reactions three patients has one kind each one with the formulation C and none with the others, with statistical significance (p <0.05). Regarding quality of life there was no significant difference when comparing all formulations however the formulation A significantly increased the quality of life of patients on the period its use. Therefore, it is concluded that similar drugs showed satisfactory results when compared to the reference product, however the replacement of the formulations may hamper the control of seizures and epilepsy management.
3

A intercambialidade entre equivalentes terapêuticos da lamotrigina: avaliação clínica e laboratorial dos pacientes portadores de epilepsia refratária / Interchangeability between therapeutic equivalents of lamotrigine: clinical and laboratory evaluation of patients with refractory epilepsy

Beatriz Maria Pereira Girolineto 27 November 2009 (has links)
A epilepsia é uma patologia caracterizada como sinal ou sintoma de uma desordem neurológica que se manifesta por breves descargas de neurotransmissores neuronais, decorrentes de distúrbios nas funções elétricas cerebrais levando a ocorrência de crises. Entre os medicamentos disponíveis no mercado, a lamotrigina (LTG) tem sido amplamente utilizada, principalmente devido a sua maior tolerabilidade e menor índice de interação farmacológica com outros fármacos antiepilépticos (DAEs). A maioria dos DAEs, e particularmente os mais novos, são de elevado custo financeiro para o paciente, portanto o sistema de saúde oferece aos seus usuários a possibilidade os receberem, porém, uma mesma regional de saúde pode variar o fornecimento de um princípio ativo entre os seus equivalentes terapêuticos disponíveis no mercado. Assim sendo, esse estudo tem a finalidade de avaliar as conseqüências clínicas e laboratoriais relacionadas à utilização de diferentes equivalentes terapêuticos da LTG (referência e similares). O estudo foi dividido em três períodos de 42 dias cada, um para cada formulação onde se realizaram atendimentos médico e farmacêutico e foram coletados dados sobre a freqüência de crises, a ocorrência de eventos adversos, dosagem plasmática de LTG e qualidade de vida dos nove pacientes incluídos no estudo. As formulações A e B são medicamentos similares e a C é o medicamento referência. Com relação ao número médio de crises foi de 3,22; 7,17 e 5,75 para as formulações A, B e C, respectivamente, no entanto essa diferença não é estatisticamente significante. Também não houve diferença significativa entre as concentrações plasmáticas de LTG. Com relação à ocorrência de reações adversas houve três casos com a formulação C e nenhum com as demais, com significância estatística (p<0,05). Quanto a qualidade de vida não houve uma diferença significativa quando se comparou todas as formulações entretanto a formulação A aumentou significativamente a qualidade de vida dos pacientes durante de sua utilização. Assim sendo, concluí-se que os medicamentos similares apresentaram resultados satisfatórios quando comparado ao medicamento de referência, entretanto a substituição das formulações pode dificultar o controle das crises epilépticas e ao manejo da epilepsia. / Epilepsy is a condition characterized as a sign or a symptom of a neurological disorder manifested by brief discharges of neuronal neurotransmitters, resulting from disturbances in electrical brain fuctions leading to crises. Among the drugs available to patients, lamotrigine (LTG) has been widely used, mainly due to their greater tolerability and lower rate of drug interactions with other antiepileptic drugs (AEDs). Most of the AEDs, and particularly the newest, have high cost to patient, so the health system offers to users the possibility to receive then, but, the same regional health can change the supply of a drug within available therapeutic equivalents in the market. Thus, this study aims to evaluate the clinical and laboratory consequences related to use of different therapeutic equivalents of LTG (reference and similar drugs). The study was divided into three periods of 42 days, one for each formulation which held medical and pharmaceutical care, and data about the frequency of seizures, the occurrence of adverse effects, measurement of plasma LTG and quality of life were collected. The formulations A and B are similar drugs and C is the reference drug. Regarding the average number of seizures it was 3.22, 7.17 and 5.75 for formulations A, B and C, respectively, however, this difference is not statistically significant. There was no significant difference between plasma concentrations of LTG. Also, regarding the occurrence of adverse reactions three patients has one kind each one with the formulation C and none with the others, with statistical significance (p <0.05). Regarding quality of life there was no significant difference when comparing all formulations however the formulation A significantly increased the quality of life of patients on the period its use. Therefore, it is concluded that similar drugs showed satisfactory results when compared to the reference product, however the replacement of the formulations may hamper the control of seizures and epilepsy management.
4

Intercambialidade entre Medicamentos Genéricos: estudo de caso Fluoxetina / Interchangeability between generic drugs: Case study Fluoxetin

Leite, Flavia Queiroz [UNIFESP] January 2013 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:45:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2013 / Introdução: No ano de 1999 foram regulamentados os medicamentos genericos no Brasil. No desenvolvimento dos medicamentos genericos sao realizados estudos em voluntarios que comprovem a bioequivalencia entre os mesmos, ou seja, dois medicamentos sao considerados bioequivalentes, quando suas biodisponibilidades forem estatisticamente comparaveis. Entretanto, isto nao garante que os medicamentos genericos aprovados sejam intercambiaveis entre si, e apenas, que eles sao intercambiaveis com o seu medicamento referencia. Objetivo: Avaliar a intercambialidade entre os medicamentos genericos contendo cloridrato de fluoxetina, registrados pela Anvisa e comercializados no pais. Metodos: Foram identificados 12 medicamentos genericos comercializados, contendo o principio ativo cloridrato de fluoxetina, na concentracao de 20 mg, na apresentacao em capsulas dura gel, destes, 2 deles foram excluidos por tratar-se de estudos de bioequivalencia repetidos (copias), e um terceiro, foi excluido por nao ter comprovado a equivalencia das variabilidades inter-individuos e intra-individuos, quando comparado aos outros estudos. A avaliacao da intercambialidade entre os medicamentos genericos foi realizada atraves de calculos estatisticos para os parametros de bioequivalencia, area sob a curva de concentracao plasmatica versus tempo (ASC0-t) e concentracao plasmatica maxima observada (Cmax). Foi utilizado o metodo proposto por Chow e Liu para a metanalise dos 9 estudos de bioequivalencia selecionados. Resultados: Todos os 9 estudos tiveram os calculos dos parametros farmacocineticos refeitos, e os intervalos de confianca 90% obtidos para as razoes dos parametros farmacocineticos Cmax e ASC dos produtos teste 1 a 9, em relacao aos seus respectivos referencias, apresentaram-se dentro dos limites estabelecidos pela Anvisa, o que significa que, foi confirmada a bioequivalencia entre cada um desses 9 medicamentos genericos com o seu respectivo referencia. Os intervalos de confianca 90% para o parametro Cmax apresentaram diferencas na velocidade de absorcao entre os produtos: - Teste 2 x Teste 6 (IC de 79,16 a 95,23%) e Teste 2 x Teste 9 (IC de 79,23 a 94,81%). Nestas duas comparacoes os intervalos de confianca extrapolaram os limites de 80% a 125%, dessa forma, de acordo com as legislacoes da Anvisa, estas formulacoes nao sao bioequivalentes entre si, o que inviabilizaria a intercambialidade entre estes medicamentos. Conclusoes: Atraves dos resultados obtidos na metanalise dos estudos de bioequivalencia dos medicamentos genericos comercializados, contendo o principio ativo cloridrato de fluoxetina, podemos concluir que, nem todos os medicamentos genericos disponiveis no mercado sao bioequivalentes entre si, podendo resultar em respostas terapeuticas diferentes nos pacientes / BV UNIFESP: Teses e dissertações
5

Intercambialidade entre medicamentos genéricos e similares de um mesmo medicamento de referência / Interchangeability among generic and similar drug products of a same reference drug product

Freitas, Marcia Sayuri Takamatsu 05 December 2016 (has links)
A implementação de medicamentos genéricos no Brasil e de programas e políticas para garantir o acesso da população a medicamentos com qualidade, segurança e eficácia resultaram em mais de 3.800 medicamentos genéricos de 445 fármacos registrados na Agência Nacional de Vigilância Sanitária (ANVISA) desde 1999. Os medicamentos genéricos comprovaram a sua equivalência terapêutica e, portanto, intercambialidade com seus respectivos medicamentos de referência por meio de estudos de bioequivalência. Em 2014, a ANVISA estendeu a intercambialidade aos medicamentos similares, aumentando o número de medicamentos intercambiáveis para cada medicamento de referência. As normas para prescrição e dispensação permitem apenas a substituição de medicamento de referência por seu medicamento genérico ou similar intercambiável e vice-versa. Entretanto, o que se observa na prática é a substituição entre medicamentos genéricos e similares de um mesmo fármaco, tanto na rede privada onde os descontos chegam até 90% do preço estabelecido para a venda, como na rede pública, em função da disponibilidade dos medicamentos, visto que as compras públicas se baseiam no menor preço ofertado pelos fabricantes. Entretanto, a bioequivalência e a intercambialidade entre os medicamentos genéricos ou similares de um mesmo referência não pode ser garantida pois os mesmos não foram testados entre si. A ausência de bioequivalência entre medicamentos substituídos pode provocar ineficácia terapêutica ou aparecimento de eventos adversos ou até mesmo intoxicação em pacientes. Consequentemente, podem ocorrer desperdício, gastos com tratamento de eventos adversos, abandono do tratamento e adoção de segunda linha de tratamentos. Este trabalho avaliou a bioequivalência entre os medicamentos genéricos e similares de um mesmo medicamento de referência por meio do método de metanálise, empregando dados de estudos de bioequivalência realizados para o registro de medicamentos genéricos e similares na ANVISA. Foram incluídos na análise estudos de aciclovir, amoxicilina, cefalexina, doxazosina, fenitoína, fluoxetina, levofloxacino e quetiapina. Os resultados demonstraram a ausência de bioequivalência entre a maioria dos medicamentos genéricos e similares contendo o mesmo fármaco. os resultados comprovam que medicamentos genéricos e similares de mesmo fármaco não são obrigatoriamente intercambiáveis e a substituição, principalmente para aqueles usados no tratamento de doenças crônicas, podem trazer graves consequências clínicas. Esta preocupação é aumentada para os fármacos com estreita faixa terapêutica e aqueles com alta variabilidade no processo de absorção. A adoção de uma lista de medicamentos não substituíveis, a exemplo de outros países, e o investimento na divulgação de informações sobre intercambialidade de medicamentos, tanto para profissionais de saúde como para a população, podem contribuir para a redução da substituição entre medicamentos não intercambiáveis, a promoção do uso racional dos medicamentos, a redução de gastos com medicamentos e tratamento de eventos adversos e o aumento da adesão do paciente ao tratamento. / The implementation of generic drugs in Brazil, as well as programs and policies to ensure access to medicines with quality, safety and efficacy to the overall population, resulted in more than 3,800 generic drug products of 445 drugs registered in the National Health Surveillance Agency (ANVISA) since 1999. Generic drug products proved their therapeutic equivalence in bioequivalence studies and, therefore, the interchangeability with their respective reference drug product. In 2014, ANVISA expanded the interchangeability to similar drug products, increasing the number of interchangeable drug products for each reference drug product. Regulations for the prescription and dispensation of medicine only allow the substitution of a reference drug product for a generic or an interchangeable similar drug product or vice versa. However, in practice, it appears that there is a substitution between generic and similar drug products of a same reference drug product in private pharmacy chains - where discounts reach up to 90% of the selling price - as well as in public pharmacy, depending on the medicine availability, because public purchases are based on the lower price offered by the manufacturers. Nevertheless, the bioequivalence and interchangeability between generic and similar drug products of the same reference drug product cannot be guaranteed because they haven\'t been evaluated. Lack of bioequivalence between substituted drug products may result in therapeutic ineffectiveness or the occurrence of adverse events and even to patient intoxication. As a consequence, there might be waste, expenses due to adverse events treatment, no adherence to the treatment or the adoption of second-line treatment. This study evaluated the bioequivalence between generic and similar drugs of the same reference drug product through a meta-analysis, using data from bioequivalence studies carried out for the registration of generic and similar drug products at ANVISA. The drugs included in the study were acyclovir, amoxicillin, cephalexin, doxazosin, phenytoin, fluoxetine, levofloxacin and quetiapine. Results showed lack of bioequivalence between most of the generic and similar drugs containing the same drug and prove that generic and similar drug products of the reference drug product are not necessarily interchangeable. Moreover, the substitution of drugs used for chronic illnesses could lead to serious clinical consequences. This concern increases for drugs with narrow therapeutic index and those with high variable absorption process. The adoption of a list of non-interchangeable medicines - like in other countries - and investment in the dissemination of information about interchangeability between drug products to health professionals and to the population may contribute to reduce the substitution of drugs which are not interchangeable, promote a rational use of medicines, the reduction of expenses with drugs and adverse effects treatment and to improve treatment adherence.
6

IEC-61850: interoperabilidade e intercambialidade entre equipamentos de supervisão, controle e proteção através das redes de comunicação de dados / IEC-61850: interoperability and interchangeability between supervision, control and protection equipment using data communication networks

Miranda, Juliano Coêlho 27 April 2009 (has links)
Os sistemas de comunicação de dados sempre foram considerados um fator crítico na operação em tempo real do sistema elétrico de potência, devido a necessidade de decisões rápidas e precisas em pontos geograficamente distribuídos, desde usinas geradoras de energia até interfaces de usuários. Com a tecnologia digital, as medições, sinalizações e comandos são encapsulados em pacotes de dados que trafegam na rede da subestação, utilizando protocolos que estabelecem os formatos, as regras, os métodos, negociando e concordando no uso de parâmetros, que assegurem o transporte de informações entre dois ou mais dispositivos do sistema de automação da subestação. Uma vez que o número de protocolos de comunicação tem se tornado um desafio para usuários e fabricantes, criando ilhas de informação, o padrão IEC-61850 busca harmonizar a diversidade de equipamentos e fabricantes, e possibilitar a integração de dados para que o máximo dos benefícios possa ser extraído. Como proposta que principia esta dissertação, ambiciona-se expor a implementação no Laboratório de Sistemas de Energia Elétrica, da Universidade de São Paulo, de uma infra-estrutura de comunicação de dados e redes de computadores, Intranet, que possibilita experimentação, medição, analise e avaliação da interoperabilidade de informações, e intercambialidade de equipamentos com supervisão, controle e proteção, essencialmente, reles digitais comerciais, aqui denominados equipamentos eletrônicos inteligentes. Com o intuito de desenvolver aplicações focadas ao estudo da automação de subestações entre os níveis de processo e bay, utilizando a infraestrututa supracitada, apresenta-se neste trabalho uma lógica para controle de um bay típico de saída de linha, dispondo de meios de comunicação de dados, e uma lógica para comutação entre fontes de alta tensão em uma subestação industrial. Estes casos oportunizaram a realização de testes quanto a troca de informações adotando o padrão IEC-61850 como protocolo de comunicação, e a rede Ethernet em substituição a fiação paralela, freqüentemente utilizada como canal de comunicação, alem da intercambialidade entre dispositivos eletrônicos inteligentes de fabricantes distintos. Houve em 100% dos casos evidenciados, correta recepção dos comandos via fiação paralela ou mensagens GOOSE. Através dos resultados obtidos, percebeu-se a estabilidade e eficiência das lógicas implementadas e uma redução nos tempos necessários para troca de informações após migração para o padrão IEC-61850. Neste ínterim, busca-se avaliar o comportamento no tempo de mensagens do tipo GOOSE, Generic Object Oriented Substation Event, em condições distintas de trafego e de configuração da topologia lógica da rede de comunicação, monitorando um possível extravio entre as mensagens geradas por um emissor e aquelas recebidas por um ou mais destinatários. Em todas as aplicações foi utilizada uma metodologia para especificar a automação das lógicas discretas mediante emprego do padrão IEC-61850, caracterizando conceitos, como, por exemplo, a especificação funcional das aplicações, o mapeamento das informações enviadas e recebidas, a definição do tipo de no lógico utilizado, a configuração do serviço de mensagens GOOSE e, a atribuição da estrutura de dados de cada no lógico aos pontos pertinentes dentro das lógicas preestabelecidas. Os resultados obtidos refletiram no ambiente laboratorial demandas reais solicitadas pelo sistema elétrico de potência. / Data communication has always been considered as a critical factor in real time operation of electric power systems. This is due to the need for fast and accurate decisions at different locations, from power generation to the user interfaces. With the digital technology, measurement, signals and commands are encrypted into data packets that travels on the substation network, using protocols that provide the format, rules, methods, dealing with parameters which ensure the traffic of information between two or more devices in the substation automation system. Since the number of communication protocols has become a challenge for users and manufacturers, creating islands of information, the IEC-61850 standard seeks for harmonization of the different equipment and manufacturers, enabling the integration of data for maximum performance. The proposal of this work is the actual implementation, at the Energy Systems Laboratory from the University of Sao Paulo, of an infrastructure of data communication network, which allows experimentation, measurement, analysis and assessment of information, interoperability and interchangeability of supervision, control and protection equipment, especially Intelligent Electronic Devices (IEDs). In order to develop applications focused on the study of automation of substations between the process and bay levels, using the infrastructure mentioned above, a logic to bay control using data communication, as well as a logic for high voltage source switching are presented. These situations test information exchange using the IEC-61850 standard as a communication protocol, and the Ethernet network replacing parallel wiring. It also tests the interchangeability amongst IEDs from different manufacturers. There were in 100% of the cases tested, correct reception of commands using parallel wiring or GOOSE messages. From the results, the stability and efficiency of the implemented logic can be observed as well as a reduction in time required to exchange information in the system. Moreover, a behavior evaluation in time of GOOSE messages was implemented for different traffic and topology conditions, monitoring possible loss of messages. In all applications a methodology to specify the automation of discrete logic using the standard IEC-61850 was implemented, featuring concepts, such as the functional specification of the applications, data mapping, the definition of the type of logic node used, the configuration of GOOSE, as well as the allocation of data structure for each logical node. The results reflects in the laboratory environment the demands requested by an actual electric power system.
7

Intercambialidade entre medicamentos genéricos e similares de um mesmo medicamento de referência / Interchangeability among generic and similar drug products of a same reference drug product

Marcia Sayuri Takamatsu Freitas 05 December 2016 (has links)
A implementação de medicamentos genéricos no Brasil e de programas e políticas para garantir o acesso da população a medicamentos com qualidade, segurança e eficácia resultaram em mais de 3.800 medicamentos genéricos de 445 fármacos registrados na Agência Nacional de Vigilância Sanitária (ANVISA) desde 1999. Os medicamentos genéricos comprovaram a sua equivalência terapêutica e, portanto, intercambialidade com seus respectivos medicamentos de referência por meio de estudos de bioequivalência. Em 2014, a ANVISA estendeu a intercambialidade aos medicamentos similares, aumentando o número de medicamentos intercambiáveis para cada medicamento de referência. As normas para prescrição e dispensação permitem apenas a substituição de medicamento de referência por seu medicamento genérico ou similar intercambiável e vice-versa. Entretanto, o que se observa na prática é a substituição entre medicamentos genéricos e similares de um mesmo fármaco, tanto na rede privada onde os descontos chegam até 90% do preço estabelecido para a venda, como na rede pública, em função da disponibilidade dos medicamentos, visto que as compras públicas se baseiam no menor preço ofertado pelos fabricantes. Entretanto, a bioequivalência e a intercambialidade entre os medicamentos genéricos ou similares de um mesmo referência não pode ser garantida pois os mesmos não foram testados entre si. A ausência de bioequivalência entre medicamentos substituídos pode provocar ineficácia terapêutica ou aparecimento de eventos adversos ou até mesmo intoxicação em pacientes. Consequentemente, podem ocorrer desperdício, gastos com tratamento de eventos adversos, abandono do tratamento e adoção de segunda linha de tratamentos. Este trabalho avaliou a bioequivalência entre os medicamentos genéricos e similares de um mesmo medicamento de referência por meio do método de metanálise, empregando dados de estudos de bioequivalência realizados para o registro de medicamentos genéricos e similares na ANVISA. Foram incluídos na análise estudos de aciclovir, amoxicilina, cefalexina, doxazosina, fenitoína, fluoxetina, levofloxacino e quetiapina. Os resultados demonstraram a ausência de bioequivalência entre a maioria dos medicamentos genéricos e similares contendo o mesmo fármaco. os resultados comprovam que medicamentos genéricos e similares de mesmo fármaco não são obrigatoriamente intercambiáveis e a substituição, principalmente para aqueles usados no tratamento de doenças crônicas, podem trazer graves consequências clínicas. Esta preocupação é aumentada para os fármacos com estreita faixa terapêutica e aqueles com alta variabilidade no processo de absorção. A adoção de uma lista de medicamentos não substituíveis, a exemplo de outros países, e o investimento na divulgação de informações sobre intercambialidade de medicamentos, tanto para profissionais de saúde como para a população, podem contribuir para a redução da substituição entre medicamentos não intercambiáveis, a promoção do uso racional dos medicamentos, a redução de gastos com medicamentos e tratamento de eventos adversos e o aumento da adesão do paciente ao tratamento. / The implementation of generic drugs in Brazil, as well as programs and policies to ensure access to medicines with quality, safety and efficacy to the overall population, resulted in more than 3,800 generic drug products of 445 drugs registered in the National Health Surveillance Agency (ANVISA) since 1999. Generic drug products proved their therapeutic equivalence in bioequivalence studies and, therefore, the interchangeability with their respective reference drug product. In 2014, ANVISA expanded the interchangeability to similar drug products, increasing the number of interchangeable drug products for each reference drug product. Regulations for the prescription and dispensation of medicine only allow the substitution of a reference drug product for a generic or an interchangeable similar drug product or vice versa. However, in practice, it appears that there is a substitution between generic and similar drug products of a same reference drug product in private pharmacy chains - where discounts reach up to 90% of the selling price - as well as in public pharmacy, depending on the medicine availability, because public purchases are based on the lower price offered by the manufacturers. Nevertheless, the bioequivalence and interchangeability between generic and similar drug products of the same reference drug product cannot be guaranteed because they haven\'t been evaluated. Lack of bioequivalence between substituted drug products may result in therapeutic ineffectiveness or the occurrence of adverse events and even to patient intoxication. As a consequence, there might be waste, expenses due to adverse events treatment, no adherence to the treatment or the adoption of second-line treatment. This study evaluated the bioequivalence between generic and similar drugs of the same reference drug product through a meta-analysis, using data from bioequivalence studies carried out for the registration of generic and similar drug products at ANVISA. The drugs included in the study were acyclovir, amoxicillin, cephalexin, doxazosin, phenytoin, fluoxetine, levofloxacin and quetiapine. Results showed lack of bioequivalence between most of the generic and similar drugs containing the same drug and prove that generic and similar drug products of the reference drug product are not necessarily interchangeable. Moreover, the substitution of drugs used for chronic illnesses could lead to serious clinical consequences. This concern increases for drugs with narrow therapeutic index and those with high variable absorption process. The adoption of a list of non-interchangeable medicines - like in other countries - and investment in the dissemination of information about interchangeability between drug products to health professionals and to the population may contribute to reduce the substitution of drugs which are not interchangeable, promote a rational use of medicines, the reduction of expenses with drugs and adverse effects treatment and to improve treatment adherence.
8

IEC-61850: interoperabilidade e intercambialidade entre equipamentos de supervisão, controle e proteção através das redes de comunicação de dados / IEC-61850: interoperability and interchangeability between supervision, control and protection equipment using data communication networks

Juliano Coêlho Miranda 27 April 2009 (has links)
Os sistemas de comunicação de dados sempre foram considerados um fator crítico na operação em tempo real do sistema elétrico de potência, devido a necessidade de decisões rápidas e precisas em pontos geograficamente distribuídos, desde usinas geradoras de energia até interfaces de usuários. Com a tecnologia digital, as medições, sinalizações e comandos são encapsulados em pacotes de dados que trafegam na rede da subestação, utilizando protocolos que estabelecem os formatos, as regras, os métodos, negociando e concordando no uso de parâmetros, que assegurem o transporte de informações entre dois ou mais dispositivos do sistema de automação da subestação. Uma vez que o número de protocolos de comunicação tem se tornado um desafio para usuários e fabricantes, criando ilhas de informação, o padrão IEC-61850 busca harmonizar a diversidade de equipamentos e fabricantes, e possibilitar a integração de dados para que o máximo dos benefícios possa ser extraído. Como proposta que principia esta dissertação, ambiciona-se expor a implementação no Laboratório de Sistemas de Energia Elétrica, da Universidade de São Paulo, de uma infra-estrutura de comunicação de dados e redes de computadores, Intranet, que possibilita experimentação, medição, analise e avaliação da interoperabilidade de informações, e intercambialidade de equipamentos com supervisão, controle e proteção, essencialmente, reles digitais comerciais, aqui denominados equipamentos eletrônicos inteligentes. Com o intuito de desenvolver aplicações focadas ao estudo da automação de subestações entre os níveis de processo e bay, utilizando a infraestrututa supracitada, apresenta-se neste trabalho uma lógica para controle de um bay típico de saída de linha, dispondo de meios de comunicação de dados, e uma lógica para comutação entre fontes de alta tensão em uma subestação industrial. Estes casos oportunizaram a realização de testes quanto a troca de informações adotando o padrão IEC-61850 como protocolo de comunicação, e a rede Ethernet em substituição a fiação paralela, freqüentemente utilizada como canal de comunicação, alem da intercambialidade entre dispositivos eletrônicos inteligentes de fabricantes distintos. Houve em 100% dos casos evidenciados, correta recepção dos comandos via fiação paralela ou mensagens GOOSE. Através dos resultados obtidos, percebeu-se a estabilidade e eficiência das lógicas implementadas e uma redução nos tempos necessários para troca de informações após migração para o padrão IEC-61850. Neste ínterim, busca-se avaliar o comportamento no tempo de mensagens do tipo GOOSE, Generic Object Oriented Substation Event, em condições distintas de trafego e de configuração da topologia lógica da rede de comunicação, monitorando um possível extravio entre as mensagens geradas por um emissor e aquelas recebidas por um ou mais destinatários. Em todas as aplicações foi utilizada uma metodologia para especificar a automação das lógicas discretas mediante emprego do padrão IEC-61850, caracterizando conceitos, como, por exemplo, a especificação funcional das aplicações, o mapeamento das informações enviadas e recebidas, a definição do tipo de no lógico utilizado, a configuração do serviço de mensagens GOOSE e, a atribuição da estrutura de dados de cada no lógico aos pontos pertinentes dentro das lógicas preestabelecidas. Os resultados obtidos refletiram no ambiente laboratorial demandas reais solicitadas pelo sistema elétrico de potência. / Data communication has always been considered as a critical factor in real time operation of electric power systems. This is due to the need for fast and accurate decisions at different locations, from power generation to the user interfaces. With the digital technology, measurement, signals and commands are encrypted into data packets that travels on the substation network, using protocols that provide the format, rules, methods, dealing with parameters which ensure the traffic of information between two or more devices in the substation automation system. Since the number of communication protocols has become a challenge for users and manufacturers, creating islands of information, the IEC-61850 standard seeks for harmonization of the different equipment and manufacturers, enabling the integration of data for maximum performance. The proposal of this work is the actual implementation, at the Energy Systems Laboratory from the University of Sao Paulo, of an infrastructure of data communication network, which allows experimentation, measurement, analysis and assessment of information, interoperability and interchangeability of supervision, control and protection equipment, especially Intelligent Electronic Devices (IEDs). In order to develop applications focused on the study of automation of substations between the process and bay levels, using the infrastructure mentioned above, a logic to bay control using data communication, as well as a logic for high voltage source switching are presented. These situations test information exchange using the IEC-61850 standard as a communication protocol, and the Ethernet network replacing parallel wiring. It also tests the interchangeability amongst IEDs from different manufacturers. There were in 100% of the cases tested, correct reception of commands using parallel wiring or GOOSE messages. From the results, the stability and efficiency of the implemented logic can be observed as well as a reduction in time required to exchange information in the system. Moreover, a behavior evaluation in time of GOOSE messages was implemented for different traffic and topology conditions, monitoring possible loss of messages. In all applications a methodology to specify the automation of discrete logic using the standard IEC-61850 was implemented, featuring concepts, such as the functional specification of the applications, data mapping, the definition of the type of logic node used, the configuration of GOOSE, as well as the allocation of data structure for each logical node. The results reflects in the laboratory environment the demands requested by an actual electric power system.

Page generated in 0.4849 seconds