• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1209
  • 44
  • 40
  • 39
  • 34
  • 27
  • 16
  • 12
  • 8
  • 8
  • 7
  • 5
  • 3
  • 1
  • 1
  • Tagged with
  • 1250
  • 648
  • 110
  • 102
  • 101
  • 101
  • 100
  • 92
  • 91
  • 86
  • 85
  • 76
  • 73
  • 73
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Analise de marcha : protocolo experimental a partir de variaveis cinematicas e antropometricas

Andrade, Luciana Meneghesso 06 July 2002 (has links)
Orientador : Ricardo Machado Leite de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-02T06:47:34Z (GMT). No. of bitstreams: 1 Andrade_LucianaMeneghesso_M.pdf: 3023849 bytes, checksum: 64106feed11ff4af860f60a49a646104 (MD5) Previous issue date: 2002 / Resumo: A marcha humana é um movimento complexo e sua análise requer um modelo de representação do corpo humano a partir de um sistema de corpos rígidos articulados com muitos graus de liberdade. Diante da dificuldade de obtenção das variáveis cinemáticas e antropométricas necessárias à análise, é freqüente na literatura a utilização de um modelo de representação apenas dos membros inferiores do corpo e da pelve. Porém, o corpo humano é um sistema articulado, de maneira que qualquer movimento alterado em uma de suas partes afetará o resultado global da marcha. A análise de todo o corpo humano durante tal ciclo de movimento seria de grande importância para a compreensão de eventuais distúrbios do movimento durante a marcha. O objetivo deste trabalho é a proposição de um protocolo experimental para análise de marcha com orientação para cabeça, tronco, pelve, membros superiores e inferiores a partir de variáveis cinemáticas e antropométricas. Este protocolo foi implementado para o sistema Dvideow. O modelo de representação e orientação dos segmentos corporais proposto neste trabalho apresenta seis graus de liberdade para cada um dos segmentos, fator importante para uma completa análise de marcha, pois os segmentos do corpo todo podem ser analisados simultaneamente, conservando seus seis graus de liberdade. A qualidade dos resultados obtidos foi avaliada a partir de testes de acurácia, em variáveis cinemáticas e antropométricas, e comparando-se os ângulos articulares obtidos segundo o protocolo proposto com dados da literatura. A concordância na segmentação do modelo proposto para análise cinemática com a do modelo antropométrico permitiu a aquisição de medidas antropométricas concomitantemente, reduzindo o tempo para a coleta e flexibilizando as condições impostas para a medição direta. A integração dos dois tipos de análise, cinemática e antropométrica, com inclusão de segmentos como cabeça e membros superiores, facilita a interpretação de distúrbios do movimento. Portanto, este trabalho desenvolveu um protocolo para análise de marcha que integra a aquisição de parâmetros cinemáticos e antropométricos do corpo todo do indivíduo apresentando resultados compatíveis com a literatura e empregando um sistema de análise de movimento de baixo custo, o que viabiliza o emprego desta metodologia no estudo mais específico dos movimentos normais ou patológicos durante a marcha / Abstract: The human gait is a complex movement and its analysis requires a model of the human body based on a system of articulated rigid bodies with several degrees of freedom. Because of the difficulty in obtaining the anthropometric and kinematics variables needed for analysis, it is common in the biomechanics field to use a representative model only involving the inferior limbs of the body and the pelvis. However, the human body is an articulated system, and any alterated movement in one of its parts will affect the global result ofthe gait. The analysis ofthe whole human body during such a movement cycle would be of great importance for the understanding of eventual disturbances of the movement during the gait. The aim of this paper is to propose an experimental protocol for gait analysis with orientation of head, trunk, pelvis, superior and inferior members from kinematics and anthropometric variables. This protocol was implemented for the Dvideow system. The orientation and representation model of the corporal segments proposed in this work presents six degrees of freedom for each one of the segments, an important factor for a complete gait analysis, because ali the body segments can be analyzed simultaneously, preserving its six degrees of freedom during gait. The quality of the results obtained was evaluated by accuracy tests, kinematics and anthropometric variables, and comparing the joint angles obtained according to protocols proposed in the literature. The agreement in the segmentation of the proposed model for kinematics analysis and the anthropometric model allowed the acquisition of anthropometrics measures concomitantly, reducing the time for the collection of reliable data and easing the imposed conditions for direct measurement. The integration these two types of analysis, kinematics and anthropometric, including the segments like head and superior members, facilitates the interpretation of the movement disturbances. In conclusion, this study developed a protocol to analyze the human gait that integrates the acquisition of kinematics and anthropometric parameters of the whole body, results presented are compatible to findings in the literature, and represents a movement analysis system of low cost. What makes feasible the use of this methodology is a more accurate analysis 'of normal pathological movements during gait / Mestrado / Mestre em Educação Física
102

Estudo do efeito de forças periodicas de tração sobre a matriz extracelular de tendão

Catalano, Ricardo 29 October 2002 (has links)
Orientador : Edson Rosa Pimentel / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-03T01:37:01Z (GMT). No. of bitstreams: 1 Catalano_Ricardo_M.pdf: 6185165 bytes, checksum: ace65328615f679660b215a5f54c4f1c (MD5) Previous issue date: 2002 / Resumo: Os tendões em geral, possuem funções importantes relacionadas com a transmissão das forças de tração geradas pela contração muscular para o osso. São estruturas adaptadas à resistir a forças de tração, e em alguns tendões podem resistir também a forças de compressão. A organização dos componentes da matriz extracelular proporcionam ao tendão grande flexibilidade, resistência e uma certa elasticidade. Estas características biomecânicas permitem ao tendão realizar trabalho com eficiência funcional e otimização operacional. A matriz extracelular de tendão é constituída por colágeno, proteoglicanos e proteínas não colagênicas. A organização e distribuição destes componentes são diferentes para diferentes tecidos dependendo da presença de forças de tração e compressão a que estão sujeitas. O objetivo deste trabalho foi analisar a organização estrutural e a composição da matriz extracelular de tendões submetidos a forças periódicas de tração. Para tanto, foram analisados tendões de cauda de ratos suspensos e comparados a ratos controle. Foram realizadas análises bioquímicas de componentes da matriz, e análise morfológica utilizando microscopia de luz normal e polarizada além da microscopia eletrônica de transmissão. As análises revelaram que os tendões caudais sob tração sofrem. modificações estruturais e físico químicas. Foi observado que no caso dos tendões suspensos, ocorreu uma maior compactação e organização das moléculas colagênicas, e que também um dos pequenos proteoglicanos, o decorim provavelmente sofre alterações em sua estrutura / Abstract: Tendons are structures capable of undergoing different adaptations to accomplish their function with efficiency. In this work we have analyzed the modifications in tendons of rat tails, which were submitted to periodic tension forces. Morphological and biochemical analyses were carried out. A waviness aspect of collagen bundles was observed for suspended tendons but not in control tendons. Also higher linear dichroism values were observed for suspended tendons, indicating the existence of a re-arrangement of the collagen bundles when submitted to tension forces. Ultrastructural analysis, showed that in the case of suspended tendons, the diameter of the fibrils of collagen were larger compared with the control. The biochemical analysis, showed no differences between the composition of the extracellular matrix of suspended and control tendons, but it was remarkable the behavior of the polydisperse proteoglycan with 140 kDa, that migrated faster in SDS PAGE, in the case of suspended tendons, indicating probably a diminishing in the size of the glycosaminoglycan chain present in that proteoglycan. It is discussed the possible effect of the polydisperse component in the increased diameter of collagen fibrils in the case of suspended tendons / Mestrado / Biologia Celular / Mestre em Biologia Celular e Estrutural
103

Adaptações das curvas da coluna vertebral na marcha em função da altura dos saltos dos calçados

Pegoretti, Cintia 25 October 2004 (has links)
Orientador: Rene Brenzikofer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-03T23:54:31Z (GMT). No. of bitstreams: 1 Pegoretti_Cintia_M.pdf: 8318379 bytes, checksum: 349743068705b009728edf1be90628f5 (MD5) Previous issue date: 2004 / Mestrado / Mestre em Educação Física
104

As adaptações das curvaturas da coluna vertebral as atividades fisicas praticadas

Wittig, Daniela Saldanha 03 August 2018 (has links)
Orientador: Rene Brenzikofer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-03T23:56:18Z (GMT). No. of bitstreams: 1 Wittig_DanielaSaldanha_M.pdf: 7848196 bytes, checksum: 8d3fca8e490f5f15519049d4710c259f (MD5) Previous issue date: 2004 / Mestrado / Mestre em Educação Física
105

Desnutrição neonatal: aspectos estruturais e biomecânicos do desenvolvimento da atividade locomotora em ratos

Mônica Ferraz Teixeira de Barros, Karla January 2006 (has links)
Made available in DSpace on 2014-06-12T23:04:22Z (GMT). No. of bitstreams: 2 arquivo9530_1.pdf: 2084113 bytes, checksum: 6ce9e5c787aa88318ae5a375c7b581ce (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Para avaliar os efeitos da desnutrição neonatal sobre o desenvolvimento motor, foram avaliadas a ontogênese dos reflexos, a atividade locomotora e as propriedades mecânicas dos músculos esqueléticos. Ratos Wistar foram divididos em grupos normais e desnutridos, de acordo com a dieta oferecida as lactantes durante o período de aleitamento (1° ao 21° dias p6s-natais - PN). Ap6s o desmame, os filhotes receberam dieta normal. A avaliação dos reflexos foi realizada diariamente, ate o 21° PN. A atividade locomotora foi avaliada no 8°, 14°, 17° e 21° PN. A avaliação biomecânica dos diferentes componentes do musculo ( contrátil/CC, elástico em serie/CES e elástico em paralelo/CEP) foi realizada oas 25 e 90 PN, nos músculos solear e extensor longo dos dedos (EDL). Uma análise histoquímica (coloração ATPase) foi também realizada. A desnutrição induziu atrasos na maturação dos reflexos de aversão ao precipício, geotaxia negativa, endireitamento em queda livre, colocação pelas vibrissas e resposta ao susto. A atividade locomotora sofreu alterações devido a desnutrição: encontrou-se redução na distância e velocidade no 8° e 14° PN, seguida por um aumento aos 17 e 21 PN. O tempo de imobilidade mostrou-se reduzido nos desnutridos aos 17 e 21 PN. A análise biomecânica demonstra que a desnutrição induziu a: redução da força em ambos os músculos estudados, aumento na velocidade máxima de encurtamento aos 25 dias em ambos os músculos, aumento na resistência a fadiga no solear a 25 PN, e aumento na resistência ao estiramento passivo em ambos os músculos, aos 25 PN. Os parâmetros do CES não foram afetados. Não se observaram diferenças em relação a proporção de tipos de fibra musculares, porem a desnutrição induziu a uma redução na área de secção transversa, com exceção do EDL aos 25 PN. Os resultados permitem concluir que as modificações observadas em algumas propriedades mecânicas tem origem na desnutrição imposta no período neonatal, sendo provavelmente devidas a alterações nos processos de maturação muscular. As influencias dos retardos nos processos de maturação sobre o desenvolvimento e organização da atividade locomotora são aqui discutidas
106

Metodologia para a suavização de dados biomecanicos por função não parametrica ponderada local robusta

Cunha, Sergio Augusto, 1959- 23 July 2018 (has links)
Orientador: Euclydes Custodio de Lima Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-07-23T20:54:54Z (GMT). No. of bitstreams: 1 Cunha_SergioAugusto_D.pdf: 3667636 bytes, checksum: 732bdd542a90c165a736cacb1fc6c488 (MD5) Previous issue date: 1998 / Resumo: o movimento humano é um fenômeno complexo que pode ser estudado por diversas áreas. A Biomecânica atua junto a outras áreas do conhecimento para buscar uma melhor compreensão do ser humano em movimento. A análise cinemática muitas vezes gera dados discretos que necessitam do ajuste de uma função contínua para representá-Ios convenientemente. Se os dados estão na forma de série de tempo, a família de curvas assim caracterizadas, que possuem uma certa distribuição de probabilidades, é chamada de processo estocástico. Suavizar os dados de uma série temporal que possuem dependência estocástica entre os valores próximos consiste em deixar os dados indicarem qual a forma da curva ajustada. Os procedimentos não paramétricos, como, por exemplo, os ajustes por partes, permitem que o dado a ser suavizado sofra influência grande dos dados próximos e nenhuma dos dados mais afastados. A literatura registra várias funções para a suavização de dados discretos. O objetivo deste trabalho é apresentar a metodologia para o ajuste de uma função não paramétrica ponderada local robusta denominada loess para a suavização de dados biomecânicos discretos a fim de descrever continuamente movimentos humanos. A metodologia consiste em escolher o tamanho da janela (parâmetro f) dentro da qual é realizada a regressão ponderada, a função peso a ser utilizada (neste caso a função tricúbica), o grau do polinômio ajustado naquela região (segundo grau para este trabalho) e comparar os valores dos resíduos com a estimação biquadrática para uma possível reponderação da regressão e exclusão dos outliers da mesma. Essa janela move-se de modo a suavizar cada ponto do vetor de dados, cujo conjunto é interpolado por uma função contínua com derivadas contínuas até segunda ordem. Nos pontos próximos das extremidades, a janela assume uma forma assimétrica com os dados mais distantes participando da suavização dos pontos nas extremidades, mas a ponderação tricúbica resolve este problema. São apresentados quatro exemplos de aplicação da função loess para suavizar dados biomecânicos: o movimento angular da perna esquerda de um garoto durante um ciclo da corrida, o movimento horizontal do tornozelo direito de um sujeito durante a realização de um chute no futebol com a bola parada, o deslocamento horizontal de um goleiro durante a realização de defesas em um teste específico de treinamento e a movimentação de um jogador profissional de futebol durante a realização de uma partida oficial. Em todos esses casos, coube ao pesquisador escolher o parâmetro de suavização (f) que fornecesse uma suavização adequada, comprovada pela análise dos resíduos, pela análise da autocorrelação dos dados e pela análise do comportamento das derivadas. A função loess mostrou-se muito apropriada na suavização de dados da cinemática do movimento humano, principalmente devido ao seu procedimento robusto para identificar os outliers e corrigir a ponderação dos dados / Abstract: Human movement is a complex phenomenon that must be studied by many areas. Biomechanics works together with other areas to search a better insight of the human movement. Many times, the kinematics analysis produce discrete data and -, one needs to adjust a continuous function to represent them with accuracy. If the data are in time series, and the curves family that is formed has a probability distribution, it is called stochastic processoTo smooth the time series data that have a stochastic dependence between the nearest values, means to leave the data show their adjustment curve shape. The non parametric procedures, partial adjustments for instance, allow that the smoothed data to receive a big influence from the neighbors and none influence from the apart points. There are a lot of functions that can be found in the literature to smooth discrete data. The aim of this work is to show a methodology for the robust local weighted non parametric function to smooth biomechanics discrete data to describe continuous human movements. The methodology consists in choosing the window size (smoothing parameter f) in witch the weighted regression will be held, the weight function that will be used (in this case, the tricubic weight), the polynomial degree adjusted in that region (second degree for this work) and compare the residuais values with the biquadratic estimation for a possible reweight in the regression to eliminate the outliers. This window moves itself so that it can smooth each point of the data vector, which ensemble will be interpolated by a continuous function that has a continuous second derivative. Near the edge points the window assumes an asymmetric form and there is a participation of the remote data, but the tricubic weight solves this problem. We show four examples of application of loess function to smooth biomechanics data: an angular movement of a boy's left shank during a cycle of a race, the horizontal movement of the right ankle of a subject during a soccer kick session with stopped ball, the goalkeeper horizontal displacement during a specific training test of defenses, and the professional soccer player movement during an official game. In ali of these cases, the researcher chose the smooth parameter (f) that provide an adequate smoothing, that were proved by the residuais analysis, by the data autocorrelation analysis and by the derivatives behaviors analysis. The loess function revealed itself very appropriate in kinematics data smoothing of the human movement, mainly depict of the robust procedure to identify outliers and to correct data weight / Doutorado / Doutor em Educação Física
107

Metodologia para descrição tridimensional do movimento humano a partir de cameras de video não sincronizadas

Barros, Ricardo Machado Leite de, 1961- 07 February 1993 (has links)
Orientador: Rene Brenzikofer / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-07-18T08:12:11Z (GMT). No. of bitstreams: 1 Barros_RicardoMachadoLeitede_M.pdf: 2085901 bytes, checksum: 0dfafd2be992000c10b23929526cb0d4 (MD5) Previous issue date: 1993 / Resumo: Este trabalho pretende contribuir para o incremento das pesquisas em Biomecânica por meio de uma metodologia para descrição tridimensional de movimentos que seja rigorosa e precisa quanto aos seus resultados, simples quanto à sua implementação, que evite causar constrangimentos à livre movimentação do sujeito estudado e acessível financeiramente. Para que obtenhamos essa descrição necessitamos, no mínimo, de duas vistas do mesmo movimento (filmagem estereoscópica) e que cada ponto de interesse seja observado simultaneamente pelas duas câmeras. O principal problema no uso de câmeras de vídeo padrão na reconstrução de movimentos é a falta de sincronização entre os registros. As causas dessa falta de sincronismo nos registros são o fato de que eles não se iniciam no mesmo instante e a possível diferença de freqüência entre os equipamentos. Para que possamos determinar a posição no espaço dos pontos de interesse a cada instante, primeiramente fazemos medições das imagens destes pontos que obtemos por meio das filmagens. Depois que nossas seqüências de imagens de vídeo foram digitalizadas e estão armazenadas em memória no computador, aplicamos um programa que realiza as medições.... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The aim of this work is to contribute to the development of research in Biomechanics with a methodology for the three-dimensional description of movements. This methodology should be both precise and of simple implementation, it should avoid constraints to the subject studied and be financially affordable. In order to obtain this description we need at least two views of the same movement (stereoscopic filming) and also that each point of interest be simultaneously observed by both cameras. The main problem in the use of standard video cameras is the lack of synchronization between registers. The causes of this lack are (1) the fact that the registers do not start at the same time and (2) the possible frequency mismatch between the machines. To determinate the position of the points of interest in space at each moment, we first measure the images of the points obtained with the filming. Aft'er having digitalized the sequences of video images and having stored them in the computer memory, we run a software which enables measurements.... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Ciencia do Esporte / Mestre em Educação Física
108

Avaliação fotoelástica da proporção coroa-implante curto com conexão cone morse

Salgado, Thiago Daher Yunes 20 September 2018 (has links)
Made available in DSpace on 2019-03-30T00:26:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2018-09-20 / Objectives: the aim of this study was to investigate the behave of unitary fixed prosthesis supported by morse taper short implants with different crown-toimplant ratios using photoelastic analysis. Materials and methods: a total of 12 morse taper cylindrical implants (TITAMAX WS CORTICAL NEODENT), with 4mm diameter and 5mm length, were individually embedded to photoelastic resin blocks. Three groups (G1, G2 and G3), containing 4 implants each, were created, according to the crown length each group would receive. Each group received a crown size to be evaluated, being in total of 3 crown sizes, whose proportions in relation to implant size were were 1x, 1,5x and 2x (5mm, 7,5mm and 10mm). After screwing the crowns onto the implants, each photoelastic resin model was positioned in a circular polariscope and a 0,5kg compressive axial and oblique (15º) loads were applied on the occlusal surface of the crowns using a universal testing machine. The images were captured by a digital camera and quantitatively analyzed using a software (Fringes®). A grid was created in order to determine 8 points around the implants to analyze the fringes patterns. The collected data was evaluated using Kruskal-Wallis test, followed by the Dunn method, with a significance level (¿) of 5%. Results: Under axial loading, the stress was concentrated at the crestal and apical regions, showing no statistical difference between crown-to-implant ratios. In contrast, under oblique loading, there was statistical difference among these 3 groups. The 10mm-crown group (G3) showed significantly more tension concentration compared to the 5mm and 7,5mm groups, G1 and G2, respectively. A greater tension concentration was found at the apical and cervical regions located on contralateral side form the implants. Conclusion: the increase in the crown-to-implant ratio leads to a greater tension concentration around the implant, specially under oblique loads. Although short dental implants have success rates similar to those longer implants, mechanical principles must be analyzed and carefully planned in order to achieve a stable and successful rehabilitation. / Objetivos: este estudo teve como objetivo avaliar os padrões das franjas fotoelásticas em torno de implantes curtos, pilares de coroas unitárias com diferentes proporções coroa-implante (C/I). Materiais e Métodos: um total de 12 implantes cilíndricos TITAMAX® WS CORTICAL NEODENT, com conexão do tipo Cone-Morse, com diâmetro (Ø)4mm e comprimento de 5mm, foram inseridos individualmente em blocos de resina fotoelástica. Foram criados 03 grupos (G1, G2 e G3) de 04 implantes, de acordo com o tamanho da coroa a ser instalada. Cada grupo recebeu um tamanho de coroa a ser avaliada, sendo no total 3 tamanhos de coroas, cujas proporções em relação ao tamanho do implante eram de 1x, 1,5x e 2x (5mm, 7,5mm e 10mm). Cada corpo de prova foi posicionado no polariscópio e sobre esse foi aplicada uma carga estática compressiva de 0,5kg, de forma obliqua (15¿) e axial. As imagens obtidas no polariscópio foram gravadas digitalmente, e baseado nas franjas isocromáticas, o estresse de cisalhamento pode ser mensurado em 8 pontos predeterminados em torno de cada implante. Os dados foram avaliados pelo teste não-paramétrico de Kruskal-Wallis, seguido pelo método de Dunn, com nível de significância (¿) de 5%. Resultados: O ensaio mecânico revelou não haver diferença estatística significante quando a proporção coroa-implante é extrapolada de 1:1 a 2:1, quando uma carga axial é aplicada. Porém, quando submetidos à carga oblíqua, há diferença estatística entre os grupos (p<0,05). Os implantes com coroas de 10mm (proporção coroa-implante 2:1), apresentaram maior concentração de tensão, quando comparados aos conjuntos com coroas de 5mm e 7,5mm, proporção coroa-implante 1:1 e 1,5:1, respectivamente. Maior concentração de tensão na região cervical contralateral à aplicação da carga e região apical do implante foi verificada quando os corpos de prova foram submetidos à carga oblíqua. Conclusão: O aumento da proporção coroa-implante acarreta maior concentração de tensão ao redor do implante. Embora implantes curtos apresentem taxas de sucessos compatíveis com implantes longos, princípios mecânicos devem ser analisados e planejados para a obtenção de uma reabilitação estável e de sucesso a longo prazo.
109

Estudo comparativo da postura de indivíduos com e sem dor na coluna vertebral /

Galera, Sandra Regina de Gouvea Padilha. January 2007 (has links)
Orientador: Luiz Fernando Costa Nascimento / Banca: Jose Elias Tomazini / Banca: Ulysses Fernandes Ervilha / Resumo: O objetivo deste estudo é comparar o alinhamento postural estático por método quantitativo, de indivíduos sintomáticos e não sintomáticos de dor na coluna vertebral. É um estudo transversal do qual participaram sujeitos com cervicalgia, lombalgia e sem queixas dolorosas. O procedimento constituiu do preenchimento do protocolo de anamnese, colocação de marcadores em pontos anatômicos específicos e obtenção de fotografias em vista anterior, posterior, lateral direita e esquerda, segundo o protocolo do Software de Avaliação Postural (SAPO). O SAPO trata-se de um programa computacional com tutoriais científicos vinculado ao CNPq. A análise das fotografias digitalizadas foi por meio deste programa que expõe os resultados pelo relatório gerado no Excel. É um programa de acesso público, que disponibiliza recursos para a análise postural, de forma a medir os ângulos em graus e em centímetro as diferenças de comprimento dos membros inferiores. Os ângulos avaliados foram analisados em módulo e suas medidas foram submetidas à análise estatística pela comparação de médias entre os três grupos utilizando o teste de ANOVA e quando comparados dois a dois, utilizou o teste t de Student, com significância de 5%. Foram identificados valores quantitativos para as variáveis de análise postural para os segmentos da cabeça, tronco e membros inferiores, nas quatro vistas. Os desvios referentes às vistas anterior e lateral direita, apresentaram maior prevalência em termos de diferença estatística entre os sujeitos dos três grupos estudados, sendo que a diferença no comprimento dos membros inferiores só se mostrou significativamente diferente entre os grupos de sujeitos com lombalgia e sujeitos assintomáticos. / Abstract: The objective of this study is to compare the postural alignment static for quantitative method, of symptomatic and not symptomatic individuals of pain in the vertebral column. It is a transversal study of which they had participated citizens with cervical pain, lombar pain and without painful complaints. The procedure it constituted to fill based on anamneses protocol, anatomic markers on specific points and photograph attainment in previous, posterior sight, lateral right and left, according to protocol of the Software of Postural Evaluation SAPO The SAPO is about a computational program with tutorial scientific tied with the CNPq. The analysis of scanned photographs was by means of this program that displays the results for the report generated in the Excel. It is a program of public access, that makes available resources for the postural analysis, of form to measure the angles in degrees and centimeter the differences of length of the inferior members. The evaluated angles had been analyzed in module and its measures had been submitted to the statistics analysis for the comparison of averages between the three groups using the test of ANOVA and when compared as couple, the T test of Student was used, with significance of 5%. Quantitative values for the 0 variable of postural analysis for the segments of the head, inferior trunk had been identified in the four sights. The referring shunting lines to the sights previous and lateral right, had presented greater prevalence in difference statistics terms enter the citizens of the three studied groups, being that the difference in the length of the inferior members if only showed significantly different in the groups of citizens with lombar pain and assymptomatic citizens. / Mestre
110

Comportamento mecânica da mola "T" de Beta-titânio : influência da marca comercial e do alivio de tensão estrutural /

Caldas, Sergei Godeiro Fernandes Rabelo. January 2013 (has links)
Orientador: Lídia Parsekian Martins / Banca: Luiz Gonzaga Gandini Junior / Banca: José Mauricio dos Santos Nunes Reis / Banca: Hallissa Simplício Gomes Pereira / Banca: Odilon Guariza Filho / Resumo: Objetivo: Os objetivos do estudo foram (1) avaliar o comportamento biomecânico das molas "T" confeccionadas com diferentes marcas comerciais de beta-titânio (β-Ti), (2) avaliar a estabilidade do sistema de força das molas 'T" pré-ativadas por curvatura quando submetidas ao alívio de tensão estrutural a longo prazo, assim como, (3) comparar seus resultados com as molas préativadas por dobras. Materiais e Métodos: No artigo 1, a amostra foi constituída de 40 molas "T" (6 x 10mm) confeccionadas com fio 0,017" x 0.025" de β-Ti e divididas em 4 grupos de 10 molas de acordo com a marca comercial: Grupo 1 - TMA® (Ormco), Grupo 2 - BETA FLEXY® (Orthometric), Grupo 3 - BETA III TiMo® (Morelli) e Grupo 4 - CNA® (Ortho Organizers). O ensaio mecânico foi realizado utilizando-se um transdutor de momentos acoplado a um indicador para extensometria, adaptado a uma máquina de ensaios mecânicos Emic (DL2000) com célula de carga de 0,1kN e velocidade 5mm/min. Para o ensaio de tração, a amostra foi constituída de 05 segmentos com 30cm de comprimento para cada marca comercial. O ensaio foi realizado na máquina de ensaios mecânicos com célula de carga de 5kN e velocidade de 2mm/min. A análise metalográfica foi realizada por fluorescência de raios X no equipamento Energy Dispersive X-ray Fluorescence Spectrometer. A dimensão dos fios calculada com auxílio de um paquímetro digital com precisão de ± 1μm. A análise estatística foi realizada por meio da análise de variância a um critério (ANOVA) e pós teste de Tukey (α=5%). No artigo 2, a amostra foi constituída de 90 molas de dimensões 6 X 10mm, confeccionadas com fios 0,017" x 0,025" de TMA®, pré-ativadas por curvatura e divididas aleatoriamente em 9 grupos de 10 molas. As molas do grupo 1 (imediato) foram avaliadas logo após a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study were (1) evaluation of the force system produced by four brands of beta-titanium (β-Ti) wires bent into a T-Loop spring (TLS), (2) evaluate changes in the force system of TLSs preactivated by curvature due to stress relaxation and (3) assess the changes in the force system of TLSs preactivated by bends and curvature. Materials and Methods: The paper 1, the sample consisted of forty springs (6 x 10mm) from 0.017" x 0.025" β-Ti and divided into 4 groups of 10 springs according to wire brand: Group 1 - TMA® (Ormco), Group 2 - BETA FLEXY® (Orthometric), Group 3 - BETA III TiMo® (Morelli) and CNA® (Ortho Organizers). The mechanical testing was performed using a moment transducer coupled to a digital extensometer indicator adapted to an Emic testing machine (DL2000) with a load cell of 0.1kN and speed 5mm/min. For the tensile test, the sample consisted of five 30cm segments of each of the wires. The test was performed on a mechanical testing machine equipped with a load cell of 5kN and speed of 2mm/min. An energy dispersive X-ray fluorescence spectrometer machine was used to determine the surface chemical composition of the wires in each group. The height and width of each wire were measured to the nearest 0.001 mm with a digital micrometer accurate to ± 1μm. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Tukey post hoc test (α=5%). The paper 2, the sample consisted of ninety TLSs with dimensions 6 x 10mm, produced out of .017" x .025" TMA® and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately and the remaining subgroups were tested after they were secured at 5 mm activation for different periods. Groups 2, 3, 4, 5, 6, 7, 8 e 9 were kept activated for 24, 48 and 72 hours... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0564 seconds