• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 185
  • 68
  • 25
  • 12
  • 12
  • 12
  • 12
  • 7
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 345
  • 345
  • 71
  • 68
  • 68
  • 46
  • 46
  • 42
  • 34
  • 33
  • 28
  • 26
  • 25
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Efeito de tratamentos térmicos nas propriedades mecânicas, eletroquímicas e citotoxidade de ligas do sistema Ti-15Mo-XNb /

Martins Júnior, José Roberto Severino. January 2014 (has links)
Orientador: Carlos Roberto Gandini / Banca: Rondinelli Donizetti Herculano / Banca: Mirian de Lourdes Noronha Motta Melo / Banca: Walter José Botta Filho / Banca: Arnaldo Rodrigues dos Santos Junior / Resumo: As ligas compostas por titânio, molibdênio e nióbio integram uma nova classe de ligas às base de titânio, sem a presença de alumínio e vanádio (que apresentam citotoxidade) e que possuem baixo valores do módulo de Young (abaixo de 100 GPa). Isto ocorre pelo fato destas ligas possuírem estrutura B, bastante atraentes para o emprego como biomateriais. Neste tipo de ligas, as variáveis de processamento podem ser controladas mais facilmente em relação às ligas a w a-B, objetivando a obtenção de propriedades melhoradas como menor módulo de elasticidade, aumento da resistência corrosão e melhor resposta do tecido ósseo. Neste trabalho foi estudado o efeito de tratamentos térmicos nas propriedades mecânicas, eletroquímicas e biocompatibilidade de ligas do sistema Ti-15%pMo-XNb(0,5, 10, 15 e 20% em peso). As ligas foram fundidas em forno a arco e caracterizadas por difração de raios X e análise pelo Método de Rietveld, microscopia eletrônica de varredura, espectroscopia por energia dispersiva (EDS), microdureza, módulo de elasticidade, resistência à corrosão e citoxidade. Com a adição de nióbio, diminui-se consideravelmente a microdureza e o mesmo ocorreu com o módulo de elasticidade, com valores em torno 80 GPa, bem abaixo do materiais metálicos comercialmente para este tipo de aplicação. Com adição de oxigênio existe uma tendência de aumento da microdureza e do módulo de elasticidade. A resistência à corrosão das ligas aumentou consideravelmente com a adição de nióbio, possuindo uma baixa densidade de corrente de corrosão. Os ensaios de citotoxidade in vitro mostraram aumento na viabilidade celular com base nos ensaios de MTTe Cristal de Violeta. Das ligas produzidas, destaca-se a Ti-15Mo-20Nb, pois possui menor microdureza e módulo de elasticidade, além de ter aumentado a viabilidade celular / Abstract: Alloys composed by titanium, molybdenum and niobium are part of a new class of titanium-based alloys, without the presence of aluminum and vanadium (which exhibit cytotoxicity) and that have low values of Young's Modulus (below 100 GPa). This occurs because these alloys have B structure, very attractive for employment as biomaterials. In this type of alloys, processing variables can be controlled more easily in relation to a - B alloys, aiming improved properties like lower modulus of elasticity, increased corrosion resistance and better response of bone tissue. In this work, we studied the effect of the addition of oxygen and heat treatments on the mechanical and electrochemical properties, and cytotoxicity, of Ti-15wt%Mo-XNb (X= 0,5, 10, 15 and 20 w%) alloys system. The alloys were melthed in arc-furnace and characterized by x-ray diffraction techniques and analysis by Rietveld method, optical and scanning electron microscopy, energy dispersive spectroscopy, (EDS), microhardness, modulus of elasticity, resistance to corrosion and cytotoxicity, The results showed promising results with the addition of niobiu. With the addition of niobium, occurs considerably decreases in the microhardness and the same occurred with the modulus of elasticity, with values around 80 GPa, below the metallic materials used commercially for this type of application. With the addition of oxygen there is a trend of increasing microhardness and modulus of elasticity. The corrosion resistance of alloys that has increased considerably with the additoion of niobium, prossessing a low corrosion current density. Cytotoxicity assays demonstrated in vitro cell viability based on MIT assay and Crystal Violet. Alloys produced, highlight the Ti-15Mo-20Nb, because it has lower hardness and modulus of elasticity, in addition to cell viability / Doutor
182

Influência do zircônio e do oxigênio na estrutura, microestrutura e propriedades mecânicas de ligas do sistema Ti-Mo-Zr /

Araújo, Raul Oliveira de. January 2017 (has links)
Orientador: Carlos Roberto Grandini / Banca: Neide Kazue Kuromoto / Banca: Conrado Ramos Moreira Afonso / Banca: Alessandra Cremasco / Banca: Carlos Nelson Elias / Resumo: Devido a uma série de fatores como o número de acidentes nos esportes, trânsito, doenças como artrite, artrose e osteoporose, a perda das funções biológicas em função do envelhecimento entre outros, acarretam a procura por materiais com a capacidade de cumprir a função de substituir partes ou funções orgânicas do corpo humano. Entre os materiais com a função de substituir tecidos humanos que suportam cargas, estão a classe dos metais, dentre esta classe destacam-se as ligas de Co-Cr, o aço ASTM F138, o titânio puro e a liga Ti-6Al-4V. Porém há a necessidade de ligas que promovam uma melhor compatibilidade mecânica e biológica. Este trabalho visa a preparação e caracterização das ligas Ti-10Mo-xZr (x = 5, 10, 15 e 20 %p), para aplicações como biomaterial. Estas ligas foram submetidas a tratamentos termomecânicos, de laminação à quente, tratamento térmico de recozimento, tratamento térmico de solubilização e tratamento térmicos em atmosfera controlada de oxigênio, para a incorporação deste elemento na liga. As ligas foram caracterizadas quimicamente por espectroscopia de emissão óptica com plasma acoplado indutivamente (ICP-OES), espectroscopia de dispersão de energia (EDS), além de análises de gases e de densidade; caracterizações estruturais e microestruturais por medidas de difração de raios X, refinamento dos difratogramas pelo método de Rietveld, microscopias óptica e eletrônica de varredura; caracterizações mecânicas por microdureza Vickers e módulo de elasticidade e cara... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Due to several factors such as the number of accidents in sports, traffic, diseases like arthritis, osteoporosis, and the loss of biological functions related to aging, among others, lead to a search for materials with the ability to fulfill the function of replacing parts or organic functions of the human body. Among the materials with the function of replacing human tissues that load-bearing, are the class of metals, and among this class are the Co-Cr alloys, the ASTM F138 stainless steel, the pure titanium and the Ti-6Al-4V alloy. However, there is a need for alloys that promote better mechanical and biological compatibility. In this sense, this work aims at the preparation and characterization of the Ti-10Mo-xZr alloys (x = 5, 10, 15 and 20 wt%) for biomaterial applications. These alloys were subjected to several kinds of thermomechanical treatments, such as hot rolling, annealing, solubilization and heat treatment in an oxygen controlled atmosphere, in order to incorporate this element into the alloy. The alloys were chemically characterized by inductively coupled plasma optical emission spectroscopy (ICP-OES), energy dispersive spectroscopy (EDS), in addition to gas and density analyzes. Structural and microstructural characterization were made by X-ray diffraction measurements, with refinement by Rietveld's method, optical and scanning electron microscopy. Mechanical characterization was made by Vickers microhardness and elastic modulus measurements, and biological cha... (Complete abstract click electronic access below) / Doutor
183

Produção de membranas antimicrobianas de fibras nanométricas contendo cinamaldeído a partir da técnica de solution blow spinning /

Lima, Aline Lins de. January 2018 (has links)
Orientador: Alexandre Luiz souto Borges / Coorientador: Eliton Souto de Medeiros / Banca: Laís Regiane da Silva Concilio / Banca: Eliandra de Sousa Trichês / Banca: Estevão Tomomitsu Kimpara / Banca: Eduardo Bresciani / Resumo: A estomatite protética é uma das afecções mais comuns e recorrentes em pacientes portadores de próteses totais. O fungo do gênero Candida, promotor dessa patologia, além de resistente se torna ainda mais complexo de ser combatido devido à dificuldade da ação de fármacos tópicos que só conseguem permanecer por um curto período no local da infecção, em virtude da dinâmica da cavidade bucal. O processo de Solution Blow Spinning permite a obtenção de fibras ultrafinas que podem ser aplicadas em vastas áreas, inclusive na bioengenharia. Uma das aplicabilidades das fibras ultrafinas é sua utilização para liberação controlada de fármacos de forma eficiente e duradoura. Dessa forma, o intuito do presente trabalho foi incorporar Cinamaldeído (CA), composto que possui propriedades antimicrobianas, a mantas de Poli(ácido lático) e Poli(etileno glicol) (PLA/PEG) e avaliá-las quanto à produção e caracterização por, Microscopia eletrônica de varredura (MEV), Termogravimetria (TGA), Calorimetria Exploratória Diferencial (DSC), Espectroscopia de infravermelho por transformada de Fourier (FTIR), Espectroscopia no ultravioleta visível (UV/vis), ensaios mecânicos e ação antifúngica. Para realização dos experimentos, foram fiadas as seguintes mantas: PLA, PLA/PEG e PLA/PEG 23,8% CA. As micrografias obtidas por MEV mostraram, que os diâmetros das fibras que não continham CA, apresentaram diâmetros semelhantes entre si, PLA (354±160 nm)a e PLA/PEG (428±250nm)a, sendo esses diâmetro menores dos que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Denture stomatitis is one of the most common and recurrent conditions in patients with total dentures. The fungal of the genus Candida, the causer of this pathology, besides being resistant, becomes even more complex to be combated due to the difficulty of the action of topical drugs that can only remain for a short time at the site of infection due to the dynamic of the oral cavity. The Solution Blow Spinning process allows the production of ultrafine fibers that can be applied in large areas, including bioengineering. One of the applications of ultrafine fibers is their use for controlled release of drugs in an efficient and long-lasting manner. Thus, the aim of the present work was to incorporate Cinnamaldehyde (CA), a compound that has antimicrobial properties, to Poly (lactic acid) and Poly (ethylene glycol) blankets (PLA / PEG) and to evaluate them for the production and characterization by Scanning Electron Microscopy (SEM), Thermogravimetric (TGA), Differential Scanning Calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), Ultraviolet-visible (UV/vis) spectroscopy, mechanical properties and antifungal action. Antifungal activity was verified against C. albicans, C. krusey and C. glabrata by broth microdilution test, disk diffusion and anti-biofilm activity, in both multi-species and mono-species biofilms. For the experiment, three types of meshes were spun: pure PLA, PLA/PEG and PLA / PEG 23.8% CA. The micrographs obtained by SEM showed that the fibers th... (Complete abstract click electronic access below) / Doutor
184

Desenvolvimento de compósitos PEUAPM / apatitas para substituição e regeração óssea

Souza, Diego Clemente de [UNESP] 31 January 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-01-31Bitstream added on 2014-06-13T19:32:51Z : No. of bitstreams: 1 souza_dc_me_araiq.pdf: 1731827 bytes, checksum: 196ae203b200a15f881b773ad6d4877d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As propriedades do polietileno de ultra alto peso molecular (PEUAPM), tais como módulo de elasticidade semelhante ao osso e baixo coeficiente de fricção, tornam este polímero muito utilizado como biomaterial para a substituição óssea, contudo, por se tratar de um material bioinerte, sua fixação ao tecido ósseo somente é possível pela utilização de componentes metálicos e cimentos ósseos à base de polimetilmetacrilato (PMMA), os quais são relacionados a efeitos biológicos severos. As biocerâmicas de fosfatos de cálcio, denominadas apatitas, são materiais que apresentam bioatividade satisfatória, ligando-se quimicamente aos tecidos vivos e dependendo de suas fases, apresentam propriedades biológicas diferenciadas, pois suas velocidades de degradação não são iguais. O compósito obtido pela combinação satisfatória do PEUAPM com diferentes fases de apatitas deve proporcionar a obtenção de um biomaterial adequado para a regeneração e reposição do tecido ósseo com atividades biológicas diferenciadas. Neste trabalho, compósitos de PEUAPM com diferentes fases de apatita de importância biológica foram desenvolvidos com o objetivo de obter um biomaterial adequado para a reposição e regeneração óssea com a combinação das propriedades mecânicas do polímero com a bioatividade satisfatória das apatitas. Foram obtidas as seguintes fases de apatitas: fosfato de cálcio amorfo (ACP), hidroxiapatita (HA), fosfato tricálcico (TCP) e fosfato octacálcico (OCP) por via úmida. A caracterização das biocerâmicas de fosfatos de cálcio foi realizada utilizando-se as técnicas de Microscopia Eletrônica de Varredura - MEV, Difratometria de Raios X - DRX e Espectroscopia no Infravermelho - IV. Biocompósitos de PEUAPM com 20, 30 e 40 % em massa das diferentes fases de apatita (ACP, HA / -TCP e OCP) foram obtidos pela... / The properties of Ultra High Molecular Weight Polyethylene (UHMWPE), as modulus of elasticity similar to bone and low coefficient of friction, make this polymer widely used as biomaterial for bone replacement, however, because it is a bio-inert material, its attachment to bone tissue is only possible by the use of metal components and bone cements based on polymethylmethacrylate, which are related to severe biological effects. The bio-ceramics of calcium phosphate, called apatite, are materials that have satisfactory bioactivity by binding chemically to living tissue and depending on their stages have different biological properties, because their speed of degradation are not equal. The association of UHMWPE with different stages of apatite provide to obtain a suitable biomaterial for the regeneration and replacement of bone tissue with different biological activities. In this study, composites of Ultra High Molecular Weight Polyethylene (UHMWPE) with different apatite phases of biological importance were developed, aiming to obtain a suitable biomaterial for bone replacement and regeneration, with the combination of mechanical properties of the polymer with satisfactory bioactivity of apatite. Were obtained the following apatite phases: amorphous calcium phosphate (ACP), hydroxyapatite (HA), tricalcium phosphate (TCP) and octacalcium phosphate (OCP) by a wet process. The characterization of the bio-ceramics of calcium phosphate was performed using the techniques of Scanning Electron Microscopy - SEM, X-Ray Diffractometry - XRD and Infrared Spectroscopy - FTIR. Biocomposites of UHMWPE with 20, 30 and 40% by weight of the different phases of apatite (ACP, HA / -TCP and OCP) were obtained by direct mixing of powders in a mortar, followed by the milling process. The method chosen to obtain the biocomposites... (Complete abstract click electronic access below)
185

Aspectos biológicos e bioatividade de materiais a base de MTA em cultura de células

Salles, Loise Pedrosa [UNESP] 10 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-10Bitstream added on 2014-06-13T20:02:14Z : No. of bitstreams: 1 salles_lp_dr_arafo.pdf: 1231496 bytes, checksum: 3488f858f33655af04a14dc9aa04ee94 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi analisar as respostas biológicas `a materiais utilizados em Endodontia que apresentam na formulação Mineral Trióxido Agregado (MTA) ou cimento Portland (PC) utilizando sistemas de cultura de células. O estudo foi dividido em três capítulos: No capitulo 1 foram avaliados bioatividade e biocompatibilidade de dois novos cimentos endodônticos comercialmente disponíveis; MTA Fillapex (MTA-F, cimento endodôntico à base de MTA, Ângelus) e Ephiphany SE (EP-SE, cimento endodôntico a base de resina metacrilato, SybronEndo). A linhagem de osteoblastos humanos (Saos-2) foi utilizada como modelo de estudo. Os resultados de MTT mostraram uma taxa significante de morte celular nas primeiras horas de exposição para todos os materiais avaliados. Entretanto, o grupo MTA-F apresentou aumento de células viáveis após 7 dias de presa. As imagens de microscopia eletrônica de varredura e o resultado de EDS (energia de dispersão atômica) mostraram diferenças na morfologia dos nódulos minerais formados pelos osteoblastos expostos ao MTA-F. No capítulo 2, células de folículo dental humanos (hDFCs) de dois terceiros molares inclusos indicados para exodontia por razões ortodônticas foram isoladas para avaliação da bioatividade e da biocompatibilidade do PC associado a diferentes agentes radiopacificadores em cultura primária de células. Os materiais estudados foram o cimento Portland branco (PC) e as associações de PC com: óxido de bismuto (CPBi), óxido de zircônio (CPZir) e tungstato de cálcio (CPCa). Além dos resultados de viabilidade celular e atividade de fosfatase alcalina, a biocompatibilidade do PC e das associações com agentes radiopacificadores foi analisada por imagens de microscopia eletrônica de varredura, que mostraram as hDFCs aderidas aos materiais. O capítulo 3 apresenta um estudo original de pesquisa básica, no qual foi avaliada... / The aim of this study was to analyze the biological responses to new endodontic materials based on Portland cement (PC) and the PC itself in cell culture systems. The study was divided into three chapters as follows: The first chapter describes a research in which the bioactivity and biocompatibility of two new commercially available sealers; MTA Fillapex (MTA-F, PC-based sealer, Angelus) and Ephiphany SE (EP-SE, resin-based sealer, SybronEndo); were evaluated in human osteoblast-like cells (Saos-2). The MTT results showed a significant cell death rate during the first hours of exposure to all test materials. After 7 days of exposure, MTA-F group showed a suitable increasing rate of cell viability. Interestingly, the images of scanning electron microscopy and the result of EDS (energy-dispersive X-ray spectroscopy) showed morphological differences in the mineralized nodules formed by osteoblasts exposed to MTA-F. In Chapter 2, human dental follicle cells (hDFCs) were isolated from two included third molars, which were extracted for orthodontic reasons. The hDFCs were suitable to assess the bioactivity and biocompatibility of PC associated with different radiopacifying agents in primary cell culture system. The materials tested were the white Portland cement (PC) and PC associations with radiopacifying agents: bismuth oxide (PCBi), zirconium oxide (PCZir) and calcium tungstate (PCCa). Besides the results of cell viability and alkaline phosphatase activity, the biocompatibility of the PC was corroborated by the images of scanning electron microscopy, which allowed us to visualize the hDFCs adhered to the material surfaces. Chapter 3 presents an original study of basic research, aimed to evaluate the hypothesis of the transcription factor NFATc1 activation in human osteoblast-like cells as a result of exposure to PC... 9Complete abstract click electronic access below)
186

Plataforma inorgânica a base de apatitas de interesse biológico visando à liberação controlada de fármacos

Almeida Filho, Edson de [UNESP] 20 January 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-01-20Bitstream added on 2014-06-13T20:42:54Z : No. of bitstreams: 1 almeidafilho_e_dr_araiq_parcial.pdf: 157037 bytes, checksum: 321cfbd062ab4368d055f07eb9e01f8d (MD5) Bitstreams deleted on 2015-02-04T11:39:24Z: almeidafilho_e_dr_araiq_parcial.pdf,Bitstream added on 2015-02-04T11:40:10Z : No. of bitstreams: 1 000694359.pdf: 1457836 bytes, checksum: bca8715aaca4bf46e0b8d064bf1df0c0 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Recobrimentos de apatitas foram realizados em superfícies de titânio modificadas por feixe de laser Yb:YAG a pressão e atmosfera ambiente. As apatitas foram depositadas pelo método biomimético usando três soluções SBF (Simulated Body Fluid) diferentes que simulam a concentração de sais dos fluídos corpóreos para obtenção das apatitas. As superfícies de titânio submetidas ao processo de fusão e solidificação rápida (ablação) foram imersas na solução de SBF, as quais permaneceram por 4 dias a 37 ºC. As amostras foram caracterizadas pelas técnicas de DRX, refinamento de Rietveld, FTIR, MEV e solubilidade. Os espectros de FTIR mostram bandas referentes às ligações químicas confirmadas pela análise de DRX e quantificadas pelo método de Rietveld. Os recobrimentos de apatitas foram submetidas ao teste de solubilidade em água destilada utilizando-se eletrodo de íons seletivos e titulação complexométrica a fim de estudar a cinética de liberação para as fases se apatitas / Apatite coatings were deposited on titanium surfaces modified by an Yb:YAG laser beam under ambient pressure and air. The apatites were deposited by a biomimetic method using three different SBF (simulated body fluid) solutions that mimic the concentration of salts in the body fluids to obtain the apatites. The titanium surfaces subjected to the process of rapid fusion and solidification (ablation) were immersed in the SBF solutions, remaining there for four days at 37ºC. The samples were characterized by X-ray diffraction (XRD), Rietveld refinement, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and solubility. The FTIR spectra showed bands corresponding to chemical bonds, which were confirmed by the XRD analysis and quantified by the Rietveld method. The apatite coatings were subjected to a solubility test in distilled water using ion-selective electrodes and complexometric titration to study the kinetics of drug release through the apatite phases
187

Processamento, caracterização microestrutural e propriedades elásticas de metais celulares do sistema Ti-6Al-4V para fins de regeneração óssea

Ruiz, Samira Lea Medina [UNESP] 22 October 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-22Bitstream added on 2014-12-02T11:20:59Z : No. of bitstreams: 1 000794568.pdf: 5749502 bytes, checksum: 5ed387d1bbca7ad42db2aa3292283c63 (MD5) / A crescente demanda por biomateriais tem exigido da ciência grandes avanços no desenvolvimento de técnicas que geram melhor qualidade de vida às pessoas que necessitam de implantes. No caso de materiais ortopédicos, estes devem apresentar resistência mecânica adequada ao seu emprego. Peças fabricadas de metais celulares de titânio é uma alternativa para redução do módulo de elasticidade, aproximando sua rigidez à do tecido ósseo, pois fornece uma combinação de baixa densidade e grande capacidade de absorção de energia. Neste trabalho foram confeccionadas estruturas celulares da liga Ti-6Al-4V, processadas por sinterização a laser direta em metais (DMLS), que é uma técnica de manufatura aditiva que reproduz protótipos virtuais 3 D camada-a-camada de forma a constituir o objeto desejado, que faz uso da energia do laser para sintetizar partículas de pó da liga Ti-6A1-4V. Para construção dos modelos virtuais utilizou-se o software SolidWorks 3D CAD Design, com um grupo de amostras com poros de geometria quadrada e um outro grupo com geometria esférica, tamanho de poros distintos de 500, 650 e 750 um e espessura de paredes celulares sempre a metade do tamanho dos poros, para obtenção de porosidades próximas a 60%. As amostras foram submetidas a tratamento térmico a 800ºC e resfriamento lento, sendo caracterizadas por microscopia eletrônica de varredura (MEV), tomografia computadorizada, dureza, densidade relativa e módulo de elasticidade (rigidez). Tanto o pó da liga quanto as amostras sinterizadas apresentam estrutura martensítica. As paredes celulares apresentam elevada rugosidade à presença de partículas do pó não sinterizadas. As imagensde MEV apresentam divergências entre tamanho de poros e espessura de parede celular. As imagens de tomografia computadorizada mostram microtrincas nas paredes celulares. Os valores de porosidade experimental diferem os valores teóricos, em média, 2% e valores de... / The growing demand for biomaterials has required of science great advances in the development of techniques that generate better quality of life for people in need of implants. In the case celular metals of titanium are an alternative for reducing the modulus of elasticity, approaching its rigidity to the bone tissue, as it provides a combination of low density, high rigidity and high energy absorption capacity. In this work made celular made cellular structures of Ti-6Al-4V alloy, processed by direct metal laser sitering (DMLS), which is an additive manufacturing techique that reproduces layer-to-layer 3D virtual prototypes in order to form the desired object, which makes use of laser energy to sintering powder particles of Ti-6Al-4V alloy. For construction of virtual models it was used the SolidWorks 3D CAD Desing software, with a group of sampls with square geometry pores, with size of 500, 650 and 750 um, and thickness cell walls always half the size of the pores, for obtaining porosity close to 60%. The samples were submited to heat treatment at 800ºC and slow cooling, being characterized by scanning electron microscopy (SEM), computed tomography, relative density, hardness and modulus of elasticity (stiffness). Both the alloy powder and sintered samples presented high roughness due to the presence of non-sintered powder particles. The SEM images presented differences between pore size and cell wall thickness. The images of computed tomography show micro failure on the cell walls. The experimental porosity values differ from the theoretical values, on average, 27% and relative density values above 0.30 were obtained for all samples. The hardness values for all cellular metals are superior to commercial alloy. The values of modulus of elasticity (siffness) suffered significant reductions (when compared with commercial alloy), with values varying between 9 and 22 GPa. According to results, the additive manufacturing showed effective...
188

Efeito de tratamentos térmicos nas propriedades mecânicas, eletroquímicas e citotoxidade de ligas do sistema Ti-15Mo-XNb / Effect of heat treatments on mechanical and electrochemical properties and cytotoxicity of Ti-15Mo-XNb system alloys

Martins Júnior, José Roberto Severino [UNESP] 03 October 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-03Bitstream added on 2015-03-03T12:06:37Z : No. of bitstreams: 1 000808440.pdf: 4763391 bytes, checksum: b971f6a92654f1cf24cfd96b483584d0 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As ligas compostas por titânio, molibdênio e nióbio integram uma nova classe de ligas às base de titânio, sem a presença de alumínio e vanádio (que apresentam citotoxidade) e que possuem baixo valores do módulo de Young (abaixo de 100 GPa). Isto ocorre pelo fato destas ligas possuírem estrutura B, bastante atraentes para o emprego como biomateriais. Neste tipo de ligas, as variáveis de processamento podem ser controladas mais facilmente em relação às ligas a w a-B, objetivando a obtenção de propriedades melhoradas como menor módulo de elasticidade, aumento da resistência corrosão e melhor resposta do tecido ósseo. Neste trabalho foi estudado o efeito de tratamentos térmicos nas propriedades mecânicas, eletroquímicas e biocompatibilidade de ligas do sistema Ti-15%pMo-XNb(0,5, 10, 15 e 20% em peso). As ligas foram fundidas em forno a arco e caracterizadas por difração de raios X e análise pelo Método de Rietveld, microscopia eletrônica de varredura, espectroscopia por energia dispersiva (EDS), microdureza, módulo de elasticidade, resistência à corrosão e citoxidade. Com a adição de nióbio, diminui-se consideravelmente a microdureza e o mesmo ocorreu com o módulo de elasticidade, com valores em torno 80 GPa, bem abaixo do materiais metálicos comercialmente para este tipo de aplicação. Com adição de oxigênio existe uma tendência de aumento da microdureza e do módulo de elasticidade. A resistência à corrosão das ligas aumentou consideravelmente com a adição de nióbio, possuindo uma baixa densidade de corrente de corrosão. Os ensaios de citotoxidade in vitro mostraram aumento na viabilidade celular com base nos ensaios de MTTe Cristal de Violeta. Das ligas produzidas, destaca-se a Ti-15Mo-20Nb, pois possui menor microdureza e módulo de elasticidade, além de ter aumentado a viabilidade celular / Alloys composed by titanium, molybdenum and niobium are part of a new class of titanium-based alloys, without the presence of aluminum and vanadium (which exhibit cytotoxicity) and that have low values of Young's Modulus (below 100 GPa). This occurs because these alloys have B structure, very attractive for employment as biomaterials. In this type of alloys, processing variables can be controlled more easily in relation to a - B alloys, aiming improved properties like lower modulus of elasticity, increased corrosion resistance and better response of bone tissue. In this work, we studied the effect of the addition of oxygen and heat treatments on the mechanical and electrochemical properties, and cytotoxicity, of Ti-15wt%Mo-XNb (X= 0,5, 10, 15 and 20 w%) alloys system. The alloys were melthed in arc-furnace and characterized by x-ray diffraction techniques and analysis by Rietveld method, optical and scanning electron microscopy, energy dispersive spectroscopy, (EDS), microhardness, modulus of elasticity, resistance to corrosion and cytotoxicity, The results showed promising results with the addition of niobiu. With the addition of niobium, occurs considerably decreases in the microhardness and the same occurred with the modulus of elasticity, with values around 80 GPa, below the metallic materials used commercially for this type of application. With the addition of oxygen there is a trend of increasing microhardness and modulus of elasticity. The corrosion resistance of alloys that has increased considerably with the additoion of niobium, prossessing a low corrosion current density. Cytotoxicity assays demonstrated in vitro cell viability based on MIT assay and Crystal Violet. Alloys produced, highlight the Ti-15Mo-20Nb, because it has lower hardness and modulus of elasticity, in addition to cell viability / FAPESP: 10/07614-6
189

Avaliação da resposta tecidual a cimentos cirúrgicos : estudo histológico realizado em alvéolo dental de ratos /

Saito, Célia Tomiko Matida Hamata. January 2005 (has links)
Orientador: Pedro Felício Estrada Bernabé / Banca: Letícia Helena Theodoro / Banca: João Eduardo Gomes Filho / Resumo: Os materiais odontológicos estão presentes em todas as especialidades. Na periodontia, aliado a uma técnica cirúrgica criteriosa, os cimentos cirúrgicos são materiais que ocupam posição importante. A proposta deste estudo foi avaliar a intensidade da resposta inflamatória e a deposição óssea em alvéolos de ratos após o implante dos cimentos cirúrgicos Coe-pak®, Perio Bond® e Voco pac®. Seguindo a remoção dos incisivos superiores direitos de 84 ratos machos (Rattus norvegicus albinus, Wistar), implantou-se em cada alvéolo um tubo de polietileno dos quais 63 estavam preenchidos com os cimentos e os restantes 21 tubos estavam vazios, compondo o grupo controle. A avaliação histológica considerou o número de células inflamatórias, a neoformação angioblástica, a densidade de fibroblastos e a presença e localização da deposição de tecido ósseo nos períodos pós-operatórios de 7, 14 e 28 dias. A análise estatística dos dados obtidos foi realizada utilizando-se Análise de Variância e teste de Krukal-Wallis. No critério infiltrado inflamatório, aos 28 dias, houve diferença estática significativa (p<0,01) entre o cimento Voco pac® e o grupo controle. Quanto à presença e localização da deposição de tecido ósseo houve diferença no grupo controle, comparando os períodos de 7 e 28 dias (p<0,01). Na associação de todos os critérios avaliados, o cimento Perio Bond® apresentou resultado menos favorável, significativamente diferente (p<0,01) do grupo controle. Respeitadas as condições experimentais deste estudo, pode-se concluir que o cimento Voco pac® evidenciou aos 28 dias maior número de células inflamatórias; enquanto cimentos Coe-pak® e Perio Bond® demonstraram comportamentos semelhantes ao grupo controle e considerando-se a associação dos resultados de todos os critérios nos períodos analisados neste estudo, o cimento Perio Bond®... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this investigation was to investigate the inflammatory tissue reaction and bone deposition in rat's dental sockets in the presence of three periodontal dressing (Coe-pak®, Perio Bond® e Voco pac®). After the exodontic removal of the right upper incisors of the eighty-four male rats, one polyethylene tube was implanted in each dental socket. Twenty one of these were empty and the other sixty-three tubes were fulfilled with periodontal dressings. The number of inflammatory cells, angioblastic neoformation, fibroblastic density and bone neoformation were evaluated after 7, 14 and 28 days. Significant differences (p<0.05) were observed in the number of inflammatory cells at 28 days, when Voco pac® was implanted. Considering bone neoformation, there was significant difference (p<0.01) between 7 and 28 days, in control group. When all events evaluated were associated, Perio Bond® showed the most severe response, which was staticcally different (p<0.01) from the control group. The following conclusions were obtained: after 28 days, Voco pac® presented at 28 days the greater number of inflammatory cells, while Coe-pak® and Perio Bond® periodontal dressings showed same number of the control group and when all events an periods of time were associated, Perio Bond® showed the most severe inflammatory response. / Mestre
190

Aspectos biológicos e bioatividade de materiais a base de MTA em cultura de células /

Salles, Loise Pedrosa. January 2012 (has links)
Orientador: Mario Tanomaru Filho / Coorientador: Ricardo Battaglino / Banca: Renato de Toledo Leonardo / Banca: Leslie Morse / Banca: Fernanda de Freitas Anibal / Resumo: O objetivo deste estudo foi analisar as respostas biológicas 'a materiais utilizados em Endodontia que apresentam na formulação Mineral Trióxido Agregado (MTA) ou cimento Portland (PC) utilizando sistemas de cultura de células. O estudo foi dividido em três capítulos: No capitulo 1 foram avaliados bioatividade e biocompatibilidade de dois novos cimentos endodônticos comercialmente disponíveis; MTA Fillapex (MTA-F, cimento endodôntico à base de MTA, Ângelus) e Ephiphany SE (EP-SE, cimento endodôntico a base de resina metacrilato, SybronEndo). A linhagem de osteoblastos humanos (Saos-2) foi utilizada como modelo de estudo. Os resultados de MTT mostraram uma taxa significante de morte celular nas primeiras horas de exposição para todos os materiais avaliados. Entretanto, o grupo MTA-F apresentou aumento de células viáveis após 7 dias de presa. As imagens de microscopia eletrônica de varredura e o resultado de EDS (energia de dispersão atômica) mostraram diferenças na morfologia dos nódulos minerais formados pelos osteoblastos expostos ao MTA-F. No capítulo 2, células de folículo dental humanos (hDFCs) de dois terceiros molares inclusos indicados para exodontia por razões ortodônticas foram isoladas para avaliação da bioatividade e da biocompatibilidade do PC associado a diferentes agentes radiopacificadores em cultura primária de células. Os materiais estudados foram o cimento Portland branco (PC) e as associações de PC com: óxido de bismuto (CPBi), óxido de zircônio (CPZir) e tungstato de cálcio (CPCa). Além dos resultados de viabilidade celular e atividade de fosfatase alcalina, a biocompatibilidade do PC e das associações com agentes radiopacificadores foi analisada por imagens de microscopia eletrônica de varredura, que mostraram as hDFCs aderidas aos materiais. O capítulo 3 apresenta um estudo original de pesquisa básica, no qual foi avaliada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the biological responses to new endodontic materials based on Portland cement (PC) and the PC itself in cell culture systems. The study was divided into three chapters as follows: The first chapter describes a research in which the bioactivity and biocompatibility of two new commercially available sealers; MTA Fillapex (MTA-F, PC-based sealer, Angelus) and Ephiphany SE (EP-SE, resin-based sealer, SybronEndo); were evaluated in human osteoblast-like cells (Saos-2). The MTT results showed a significant cell death rate during the first hours of exposure to all test materials. After 7 days of exposure, MTA-F group showed a suitable increasing rate of cell viability. Interestingly, the images of scanning electron microscopy and the result of EDS (energy-dispersive X-ray spectroscopy) showed morphological differences in the mineralized nodules formed by osteoblasts exposed to MTA-F. In Chapter 2, human dental follicle cells (hDFCs) were isolated from two included third molars, which were extracted for orthodontic reasons. The hDFCs were suitable to assess the bioactivity and biocompatibility of PC associated with different radiopacifying agents in primary cell culture system. The materials tested were the white Portland cement (PC) and PC associations with radiopacifying agents: bismuth oxide (PCBi), zirconium oxide (PCZir) and calcium tungstate (PCCa). Besides the results of cell viability and alkaline phosphatase activity, the biocompatibility of the PC was corroborated by the images of scanning electron microscopy, which allowed us to visualize the hDFCs adhered to the material surfaces. Chapter 3 presents an original study of basic research, aimed to evaluate the hypothesis of the transcription factor NFATc1 activation in human osteoblast-like cells as a result of exposure to PC... 9Complete abstract click electronic access below) / Doutor

Page generated in 0.1221 seconds