• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de sensores eletroanalíticos utilizando eletrodos modificados com filme de Bismuto / Development of electroanalytical sensors utilizing modified electrodes with Bismuth Film

Fernando Castro Mota de Oliveira 15 August 2008 (has links)
A utilização de eletrodos modificados com filmes de Bismuto, formados in situ, é um método prático para a determinação de metais através da pré-concentração e redissolução anódica, pois a modificação do eletrodo e a pré-concentração dos analitos são realizadas simultaneamente. O processo de fabricação de eletrodos de Au através de CD-Rs é uma alternativa barata para a confecção de eletrodos descartáveis, pois devido ao baixo custo e facilidade, com um único CD-R é possível produzir de um grande número de eletrodos possibilitando a realização de várias medições. Quando não mais apresentar o comportamento desejado, o sensor simplesmente é descartado. Tal processo é vantajoso no sentido de que após a realização da redissolução dos metais préconcentrados no eletrodo, o mesmo pode não apresentar o perfil anterior devido a uma quantidade residual de bismuto do filme remanescente no eletrodo. Devido a facilidade de produção de eletrodos de CD-R foram construídos sistemas integrados contendo os três eletrodos necessário para a célula eletroquímica através da técnica de corrosão com iodo/iodeto. Tal processo foi realizado fazendo-se a proteção das áreas dos eletrodos com toner de impressora, transferido termicamente. Após a corrosão, o toner é retirado com algodão embebido em acetonitrila. Um eletrodo de (pseudo) referência (Ag/AgCl KCl 0,1 mol L-1) foi incorporado ao sistema através da eletrodeposição de Ag sobre um dos três eletrodos de Au e posterior reoxidação de uma porção da Ag eletrodepositada em meio contendo íons cloreto para a formação de AgCl. Tal sistema apresentou uma boa repetibilidade de medidas de voltametria de onda quadrada realizadas após a pré-concentração sobre filmes de Bi formado in situ em soluções de Pb e Cd a uma concentração de 2,0x10-6 mol L-1. A concentração de Bi3+ utilizado para a formação do filme foi de 1,0x10-4 mol L-1. O estudo da concentração dos íons Bi3+ utilizado para a formação do filme mostrou-se um parâmetro que afeta crucialmente o formato das curvas analíticas para ambos os metais Cd e Pb, apresentando variações na sensibilidade do método para ambos os metais e dificultando a determinação conjunta dos mesmos para concentrações mais baixas. A quantificação destes metais foi realizada em amostras de urina e de combustíveis como óleo Diesel e Biodiesel através do método de adição de padrões, os quais se apresentaram em faixas a nível de traços (µg.L-1). / The use of in situ Bismuth film modified electrodes is a practice method for the determination of metals by a preconcentration and anodic stripping, because the modification of electrode and preconcentration of analites in made simultaneously. The Au electrode manufacturing by CD-Rs is a cheap alternative method to build disposable electrodes, due the low cost and easily, with a unique CD-R is possible the production of a great number of electrodes whose possibility the realization of many measurements. When the preview behavior is anymore observed, the sensor is just discarded. This process is advantageous in the sense of after the stripping step, in which the pre-concentrated metals is getting out the electrode, the same cannot represent itself as the beginning profile, due a residual quantity of bismuth in the film remainder in the electrode. Because the easily of production of CD-R electrodes were made array of Au electrodes containing three electrodes, necessarily to electrochemistry cell, by the etching technique with iodide/iodine. This process was made using the protection of electrodes area with laser printer ink, by the thermal transference. After the etching, the toner ink is removed with swab cotton, absorbed in acetonitrile. A pseudo reference electrode (Ag/AgCl KCl 0,1 mol L-1) was incorporated to the system by electrodepositing of a Ag film on one of the three Au electrodes and following the reoxidation of a portion of Ag in a medium containing clorine ions to the formation of Ag/AgCl. The system show a good repeatability of square-wave voltammetry measures carry out through the preconcentration on Bi film formed in situ of Pb and Cd in a concentration of 2,0x10-6 mol L-1. The concentration of Bi3+ utilized to formation of in situ film was 1x10-4 mol L-1. The study of Bi3+ ions concentration shows that the same is an important parameter who affects crucially the format of analytical curves for both metals Cd e Pb, presenting variations in the sensibility of method for both metals and difficulting the simultaneous determination of these metals for lower concentrations. The quantification of theses metals was realized in urine and fuel oils, as Diesel oil and Biodiesel samples by the standard-addition method, whose was found in traces level concentration (&#181g L-1)
2

Desenvolvimento de sensores eletroanalíticos utilizando eletrodos modificados com filme de Bismuto / Development of electroanalytical sensors utilizing modified electrodes with Bismuth Film

Oliveira, Fernando Castro Mota de 15 August 2008 (has links)
A utilização de eletrodos modificados com filmes de Bismuto, formados in situ, é um método prático para a determinação de metais através da pré-concentração e redissolução anódica, pois a modificação do eletrodo e a pré-concentração dos analitos são realizadas simultaneamente. O processo de fabricação de eletrodos de Au através de CD-Rs é uma alternativa barata para a confecção de eletrodos descartáveis, pois devido ao baixo custo e facilidade, com um único CD-R é possível produzir de um grande número de eletrodos possibilitando a realização de várias medições. Quando não mais apresentar o comportamento desejado, o sensor simplesmente é descartado. Tal processo é vantajoso no sentido de que após a realização da redissolução dos metais préconcentrados no eletrodo, o mesmo pode não apresentar o perfil anterior devido a uma quantidade residual de bismuto do filme remanescente no eletrodo. Devido a facilidade de produção de eletrodos de CD-R foram construídos sistemas integrados contendo os três eletrodos necessário para a célula eletroquímica através da técnica de corrosão com iodo/iodeto. Tal processo foi realizado fazendo-se a proteção das áreas dos eletrodos com toner de impressora, transferido termicamente. Após a corrosão, o toner é retirado com algodão embebido em acetonitrila. Um eletrodo de (pseudo) referência (Ag/AgCl KCl 0,1 mol L-1) foi incorporado ao sistema através da eletrodeposição de Ag sobre um dos três eletrodos de Au e posterior reoxidação de uma porção da Ag eletrodepositada em meio contendo íons cloreto para a formação de AgCl. Tal sistema apresentou uma boa repetibilidade de medidas de voltametria de onda quadrada realizadas após a pré-concentração sobre filmes de Bi formado in situ em soluções de Pb e Cd a uma concentração de 2,0x10-6 mol L-1. A concentração de Bi3+ utilizado para a formação do filme foi de 1,0x10-4 mol L-1. O estudo da concentração dos íons Bi3+ utilizado para a formação do filme mostrou-se um parâmetro que afeta crucialmente o formato das curvas analíticas para ambos os metais Cd e Pb, apresentando variações na sensibilidade do método para ambos os metais e dificultando a determinação conjunta dos mesmos para concentrações mais baixas. A quantificação destes metais foi realizada em amostras de urina e de combustíveis como óleo Diesel e Biodiesel através do método de adição de padrões, os quais se apresentaram em faixas a nível de traços (µg.L-1). / The use of in situ Bismuth film modified electrodes is a practice method for the determination of metals by a preconcentration and anodic stripping, because the modification of electrode and preconcentration of analites in made simultaneously. The Au electrode manufacturing by CD-Rs is a cheap alternative method to build disposable electrodes, due the low cost and easily, with a unique CD-R is possible the production of a great number of electrodes whose possibility the realization of many measurements. When the preview behavior is anymore observed, the sensor is just discarded. This process is advantageous in the sense of after the stripping step, in which the pre-concentrated metals is getting out the electrode, the same cannot represent itself as the beginning profile, due a residual quantity of bismuth in the film remainder in the electrode. Because the easily of production of CD-R electrodes were made array of Au electrodes containing three electrodes, necessarily to electrochemistry cell, by the etching technique with iodide/iodine. This process was made using the protection of electrodes area with laser printer ink, by the thermal transference. After the etching, the toner ink is removed with swab cotton, absorbed in acetonitrile. A pseudo reference electrode (Ag/AgCl KCl 0,1 mol L-1) was incorporated to the system by electrodepositing of a Ag film on one of the three Au electrodes and following the reoxidation of a portion of Ag in a medium containing clorine ions to the formation of Ag/AgCl. The system show a good repeatability of square-wave voltammetry measures carry out through the preconcentration on Bi film formed in situ of Pb and Cd in a concentration of 2,0x10-6 mol L-1. The concentration of Bi3+ utilized to formation of in situ film was 1x10-4 mol L-1. The study of Bi3+ ions concentration shows that the same is an important parameter who affects crucially the format of analytical curves for both metals Cd e Pb, presenting variations in the sensibility of method for both metals and difficulting the simultaneous determination of these metals for lower concentrations. The quantification of theses metals was realized in urine and fuel oils, as Diesel oil and Biodiesel samples by the standard-addition method, whose was found in traces level concentration (&#181g L-1)
3

Determinação simultânea de Cd, Pb e Cu em amostras de chá (Camellia sinensis) por voltametria de onda quadrada e redissolução anódica

Medeiros, Cleilson Lucena de 31 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2016-05-04T13:53:54Z No. of bitstreams: 1 arquivo total.pdf: 4473867 bytes, checksum: e3130e71f9f870684d06304ce755007d (MD5) / Made available in DSpace on 2016-05-04T13:53:54Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 4473867 bytes, checksum: e3130e71f9f870684d06304ce755007d (MD5) Previous issue date: 2015-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This paper describes the development of a method for quantification Cd2+, Pb2+ and Cu2+ cations, in teas, performed simultaneously, using Square Wave Anodic Stripping Voltammetry carbon nanotube paste electrode modified with bismuth film. Tea is one of the most beneficial and consumed beverage through the world, being prepared from the infusion parts of the plant Camellia sinensis. Most commonly this kind of tea presents metal ions, such as Cd 2+, Pb 2+ and Cu 2+, which offers health risk, in case of being ingested above the limit. To detect these metals, it is necessary to make use of techniques with high sensitivity. The spectrometric methods are the most widely used, but they have a high cost, are laborious and expensive. The voltammetric techniques are characterized by being inexpensive and having equal sensitivity, and even greater than some spectrometric methods. The parameters of the technique used were obtained after optimization with fractional factorial design. The tea samples were prepared through digestion with heating by microwave radiation in a closed system using diluted nitric acid and hydrogen peroxide. The method was validated based on the sample certified plant tissue (forage Marandu) and applied in green and black tea samples. Recoveries of cations Cd 2+, Pb 2+ and Cu 2+ ranged from 79.3 to 107.6%, the certified sample, and 73.3 to 122.1% in the evaluated samples of teas. The detection limits obtained in the simultaneous analysis of Cd 2+, Pb 2+ and Cu 2+ were 0.16; 0.20; 0.39 ug L-1, respectively. Cu2 + was detected only in samples of tea, but the method was efficient for the simultaneous quantification of all metals in the matrix assessed after the addition and recovery. / Este trabalho descreve o desenvolvimento de um método de quantificação dos cátions Cd2+, Pb2+ e Cu2+, em chás, realizada de forma simultânea, empregando voltametria de onda quadrada por redissolução anódica com eletrodo de pasta de nanotubo de carbono modificado por filme de bismuto. O chá é uma das bebidas mais benéficas e consumidas no mundo, sendo preparado a partir da infusão de partes da planta Camellia sinensis. Normalmente são encontrados cátions metálicos, como o Cd2+, Pb2+ e Cu2+, que se ingeridos acima do limite máximo representam riscos à saúde. Para detectar esses metais é necessário fazer uso de técnicas com alta sensibilidade. Os métodos espectrométricos são os que mais amplamente tem sido utilizado, porém apresentam custo elevado, são laboriosos e dispendiosos. As técnicas voltamétrica caracterizam-se por serem baratas e possuir sensibilidade igual e até maior que alguns métodos espectrométricos. Os parâmetros da técnica utilizada foram obtidos após otimização com planejamento fatorial fracionário. As amostras de chá foram preparadas via digestão com aquecimento por radiação micro-ondas em sistema fechado empregando ácido nítrico e peróxido de hidrogênio diluídos. A validação do método foi realizada com base na amostra certificada de tecido vegetal (forrageira Marandu) e aplicada em amostras de chá verde e preto. As recuperações dos cátions Cd2+, Pb2+ e Cu2+ variaram de 79,3 a 107,6%, na amostra certificada, e de 73,3 a 122,1% nas amostras de chás avaliadas. Os limites de detecção obtidos na análise simultânea de Cd2+, Pb2+ e Cu2+, foram 0,16; 0,20; 0,39 μg L-1, respectivamente. Foi detectado apenas Cu2+ nas amostras de chá, porém o método se mostrou eficiente para quantificação simultânea de todos os metais na matriz avaliada após a adição e recuperação.
4

Multilayer graphene modified metal film electrodes for the determination of trace metals by anodic stripping voltammetry

Zbeda, Salma Gumaa Amar January 2013 (has links)
Magister Scientiae - MSc / In this study multilayer graphene nanosheets was synthesize by oxidizing graphite to graphene oxide using H2SO4 and KMnO4 followed by reduction of graphene oxide to graphene using NaBH4. The graphene nanosheets were characterized by Fourier Transform Infrared (FTIR) and Raman spectroscopy, high resolution transmission electron microscopy (HRTEM), Scanning electron microscopy (SEM) and X-ray diffraction (XRD). HRTEM images showed that the multilayer graphene were obtained. The graphene was immobilized directly onto a glassy carbon electrode using the drop coating technique followed by the in situ deposition of mercury, bismuth or antimony thin films to afford graphene modified glassy carbon metal film electrodes (Gr-GC-MEs). The experimental parameters (deposition potential, deposition time, rotation speed, frequency and amplitude) were optimized, and the applicability of the modified electrode was investigated towards the individual and simultaneous determination of Zn2+, Cd2+ and Pb2+ at the low concentration levels (μg L-1) in 0.1 M acetate buffer (pH 4.6) using square wave anodic stripping voltammetry (SWASV). The detection limits values for the Gr-GC-HgE was 0.08, 0.05 and 0.14 μg L-1 for Zn2+, Cd2+ and Pb2+, respectively. The Gr-GC-BiE the detection limits for was 0.12, 0.22 and 0.28 μg L-1 for Zn2+, Cd2+ and Pb2+ while the detection limits for the Gr-GC-SbE was 0.1, 0.3 and 0.3 μg L-1 for Zn2+, Cd2+ and Pb2+, respectively. A Gr-GCE prepared without any binding agents or metal film had detection limits for Zn2+, Cd2+ and Pb2+ of 3.9, 0.8 and 0.2 μg L-1 for Zn2+, Cd2+ and Pb2+. Real sample analysis of which was laboratory tap water was performed using the Gr-GCMEs. Only Gr-GC-HgE was sensitive enough to detect metal ions in the tap water samples at the 3ppb level whereas, the GC-BiE and GC-SbE detected the metal ions at the 10 μg L-1 to 30 μg L-1 level.

Page generated in 0.07 seconds