• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 15
  • 5
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 16
  • 15
  • 15
  • 12
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Obtención y caracterización de nuevos cementos óseos de fosfatos de calcio en el sistema CaHPO4--- -Ca3 (PO4)2

Fernández Aguado, Enrique 18 December 1996 (has links)
La presente Tesis Doctoral se titula "Obtención y caracterización de nuevos cementos óseos de fosfatos de calcio en el sistema DCP&#8213;alfa-TCP". Los cementos de fosfatos de calcio (CFC) son materiales biocompatibles que tienen la propiedad de endurecer en condiciones fisiológicas formando una estructura porosa de cristales interconectados de hidroxiapatita, i.e. la fase mineral de los tejidos óseos. Estos materiales pueden ser diseñados para que sean inyectables y tengan distintos porcentajes de porosidad. Este hecho permite obtener cementos con distintas tasas de reabsorción ósea que pueden aplicarse con técnicas de mínima invasión. En general, estas propiedades otorgan a estos biomateriales un excelente interés en campos de aplicación de prevención, reconstrucción o estabilización ósea (p.e.: osteoporosis, cirugía craneofacial, vertebroplastia, cifoplastia).Esta Tesis Doctoral consta de 6 capítulos. El Capítulo 1 (Cementos óseos de fosfatos de calcio) recoge el estado del arte de los CFC. Se realiza una revisión bibliográfica crítica de toda la información de interés. Se concluye la necesidad de realizar estudios cinéticos que expliquen adecuadamente las propiedades de fraguado de estos cementos y permitan diseñar cementos con mejores propiedades. El Capítulo 2 (Materiales y métodos utilizados en la fabricación y caracterización de cementos óseos de fosfatos de calcio) describe el protocolo de trabajo seguido para caracterizar los CFC física y químicamente. Este protocolo permite establecer correlaciones entre la microestructura y las propiedades macroscópicas. El Capítulo 3 (Estudio de la cinética de la reacción de fraguado de un cemento óseo de fosfato de calcio) investiga la cinética de fraguado de un cemento octocálcico en el sistema DCP&#8213;alfa-TCP. Los resultados mostraron que: (a) sólo el alfa-TCP reaccionó para dar una hidroxiapatita deficiente en calcio (CDHA); (b) el porcentaje de reacción y la resistencia mecánica a compresión estaban correlacionadas; (c) el cemento presentó una estructura de cristales interconectados con distinto grado de compacidad. El Capítulo 4 (Estudio de nuevas formulaciones de cementos de fosfatos de calcio en el sistema DCP&#8213;alfa-TCP) investiga las propiedades de fraguado y de resistencia mecánica de cementos del sistema DCP&#8213;alfa-TCP en el intervalo de relaciones Calcio/Fósforo (Ca/P) 1.26<Ca/P<1.50. Se estudia cómo varían la trabajabilidad, los tiempos de fraguado y la resistencia a la compresión. También se estudia el efecto de la adición de carbonato cálcico (CC) sobre las propiedades de fraguado ya que se espera obtener como producto final de la reacción de fraguado una hidroxiapatita deficiente en calcio carbonatada y, por lo tanto, más semejante a la apatita de la fase mineral ósea. Los resultados mostraron que la adición de un 10 % de CC produjo un efecto fluidificante sobre los cementos con un incremento en los valores de los tiempos de fraguado. El análisis de la evolución de la resistencia a la compresión con el tiempo demostró que el CC actúa como un retardador. Sin embargo, la resistencia final alcanzada representa en muchos casos un incremento de más del 40 %. El Capítulo 5 (Discusión general) discute los resultados más relevantes analizados a lo largo de los Capítulos 3 y 4 para comprender las posibilidades clínicas que este tipo de materiales nos ofrece. El Capítulo 6 (Conclusiones) presenta una serie de conclusiones obtenidas a partir de los resultados de los Capítulos 3 y 4. Son conclusiones extraídas a partir del análisis de los resultados de determinadas poblaciones de muestras. Como los intervalos de variabilidad de los parámetros de cada población son diferentes, muchas de las conclusiones no son generalizables a todo el sistema DCP&#8213;alfa-TCP, sino que se han de leer dentro de este sistema y en las condiciones experimentales estudiadas. Finalmente, la Tesis Doctoral lista el conjunto de referencias bibliográficas utilizadas en este trabajo de investigación.
42

Deformačně napěťová analýza proximálního femuru s dříkem endoprotézy a zlomeninou / Stress analysis of proximal femur with the stem of the prosthesis and the fracture

Kalová, Miroslava January 2012 (has links)
This work is focused on a solving of problems regarding a total hip replacement with a fractured femur. The fracture is located in the distal end of the total joint replacement stem and the fracture is spreading in the proximal direction on the boundary of the bone and cement. A proximal part of femur is reinforced by fixing tape. There is also briefly described how computer models were carried out. Furthermore a stress - strain analysis of solved system has been performed in this work. The solution was realized using the finite element method in computational program ANSYS Workbench. Different variants with change of a fracture range and number of fixing tapes were considered during the solving. Stress - strain analysis shows that due a application of fourth fixing tape occurs lowering of main stresses values in the femur in fracture region. Simultaneously occurs a reduction of Equivalent stress values on a distal part of stem.
43

Évaluation de la stabilité primaire d'une greffe ostéochondrale autologue stabilisée au moyen d'un ciment ostéoconducteur résorbable

Kiss, Marc-Olivier 12 1900 (has links)
L’objectif de cette étude est de vérifier si un ciment ostéoconducteur résorbable utilisé comme technique de fixation de greffons ostéochondraux permet d'obtenir une stabilité initiale supérieure à celle obtenue avec la technique de mosaicplastie originalement décrite. Il s’agit d’une étude biomécanique effectuée sur des paires de fémurs cadavériques bovins. Pour chaque paire de fémurs, des greffons ostéochondraux autologues ont été insérés et stabilisés au moyen d’un ciment biorésorbable (Kryptonite, DRG inc.) sur un fémur alors qu’au fémur controlatéral, les greffons ont été implantés par impaction selon la technique usuelle de mosaicplastie. Des greffons uniques ainsi que des greffons en configuration groupée ont été implantés et soumis à une évaluation biomécanique. Les charges axiales nécessaires pour enfoncer les greffons de 1, 2 et 3 mm ont été comparées en fonction de la technique de stabilisation utilisée, ciment ou impaction, pour chaque configuration de greffons. Les résultats démontrent que les greffons ostéochondraux cimentés uniques et groupés ont une stabilité initiale supérieure à celle de greffons non cimentés sur des spécimens cadavériques bovins. L’obtention d’une plus grande stabilité initiale par cimentation des greffons ostéochondraux pourrait permettre une mise en charge précoce post-mosaicplastie et mener à une réhabilitation plus rapide. / The objective of this project is to compare the primary stability of osteochondral autografts stabilized with a resorbable osteoconductive bone cement to that of bottomed press fit grafts inserted according to the original mosaicplasty technique. Biomechanical testing was conducted on pairs of cadaveric bovine femurs. For each femoral pair, osteochondral grafts were inserted and stabilized with an osteoconductive bone cement (Kryptonite, DRG inc.) on one bone whereas on the controlateral femur, grafts were inserted in a press fit fashion. Grafts were inserted in 2 different configurations, single grafts as well as groups of 3 adjacent grafts, and submitted to biomechanical testing. Axial loads needed to sink the grafts to 1, 2 and 3 millimeters below cartilage level were recorded and compared according to the fixation technique, cement or press-fit impaction, for each graft configuration. According to those results, cemented osteochondral autografts appear more stable than press fit grafts for both single and 3-in-a-row configurations. Using such a cementation technique could potentially prevent the initial loss of stability that has been shown to occur with osteochondral grafts in the post-operative period, allowing patients to perform early weight bearing and rehabilitation.
44

Formação de biofilme bacteriano sobre polimetilmetacrilato usado como cimento ósseo / Formation of bacterial biofilm on polymethylmetacrylate used as bone cement

Campos Júnior, Flávio Ferraz de 10 June 2009 (has links)
A infecção bacteriana é a principal complicação que um procedimento de artroplastia de quadril ou joelho pode apresentar. Mesmo após a incorporação de antibiótico (gentamicina) ao cimento ósseo, as taxas de infecções após este procedimento cirúrgico continuam gerando sérios prejuízos para o hospital e para o paciente. As principais bactérias envolvidas nas infecções relacionadas aos implantes ortopédicos são Pseudomonas aeruginosa, Staphylococcus aureus e Staphylococcus epidermidis. O objetivo deste trabalho foi avaliar a aderência e formação de biofilme de S. aureus, S. epidermidis e P. aeruginosa sobre o cimento ósseo polimetilmetacrilato (PMMA) com e sem antibiótico (gentamicina), de procedência nacional e internacional, por meio de microscópio eletrônico de varredura (MEV) e por cultura. Também, estimar quantitativamente as células viáveis recuperadas dos biofilmes formados. Foram produzidos discos de polimetilmetacrilato de 10,0 mm de diâmetro e 3,0 mm de espessura. Foram utilizadas cepas Pseudomonas aeruginosa - ATCC 27853, Staphylococcus epidermidis - ATCC 12228 e Staphylococcus aureus - ATCC 25932. Para este estudo foram utilizados corpos-de-prova de cimento ósseo de procedência nacional (BAUMER, CMM e BIOMECANICA) e internacional (BIOMET com gentamicina, BIOMET sem gentamicina e SIMPLEX). Biofilmes foram produzidos in vitro a partir da inoculação da suspensão bacteriana (\'10 POT.8\' unidades formadoras de colônia/mL) em Tryptic Soy Broth e incubados nos períodos de tempo de 1, 6, 24, 48, e 72 horas. Após os períodos de incubação os corpos-de-prova foram removidos do meio de cultura, lavados, sonicados e do sobrenadante realizadas diluições seriadas (\'10 POT.-1\' a \'10 POT.-5\'). A seguir, os corpos-de-prova foram preparados para observação por MEV. Os resultados de MEV mostraram bacilos e cocos aderidos e agrupados formando biofilme. Para P. aeruginosa: as contagens das células viáveis em média (UFC/mL) foram de 2,8 \'+ OU -\' 1,7 x \'10 POT.6\' (BAUMER), 1,7 \'+ OU -\' 0,9 x \'10 POT.6\' (BIOMECANICA), 1,7 \'+ OU -\' 0,7 x \'10 POT.6\' (CMM), 1,6 \'+ OU -\' 0,7 x \'10 POT.6\' (BIOMET sem gentamicina), 6,0 \'+ OU -\' 5,5 x \'10 POT.4\' (BIOMET com gentamicina) e 1,9 \'+ OU -\' 0,9 x \'10 POT.6\' (SIMPLEX); para S. epidermidis: 1,3 \'+ OU -\' 0,1 x \'10 POT.6\' (BAUMER), 1,5 \'+ OU -\' 0,2 x \'10 POT.6\' (BIOMECANICA), 2,3 \'+ OU -\' 1,7 x \'10 POT.6\' (CMM), 1,5 \'+ OU -\' 0,7 x \'10 POT.6\' (BIOMET sem gentamicina), 1,5 \'+ OU -\' 0,2 x \'10 POT.6\' (BIOMET com gentamicina) e 1,2 \'+ OU -\' 0,1 x \'10 POT.6\' (SIMPLEX); para S. aureus: 1,7 \'+ OU -\' 0,8 x \'10 POT.6\' (BAUMER), 1,6 \'+ OU -\' 0,7 x \'10 POT.6\' (BIOMECANICA), 1,4 \'+ OU -\' 0,6 x \'10 POT.6\' (CMM), 1,1 \'+ OU -\' 0,5 x \'10 POT.6\' (BIOMET sem gentamicina), 3,0 \'+ OU -\' 6,0 x \'10 POT.5\' (BIOMET com gentamicina) e 1,3 \'+ OU -\' 0,6 x \'10 POT.6\' (SIMPLEX), respectivamente. Os dados obtidos mostraram que o cimento ósseo de polimetilmetacrilato com e sem gentamicina não evitaram a aderência da Pseudomonas aeruginosa, Staphylococcus epidermidis e Staphylococcus aureus e formação de biofilme, como demonstrado pela MEV. Em conclusão, isto é um fator de risco para infecções. / The bacterial infection is the main complication of a procedure for hip or knee arthroplasty can present. Even after the addition of antibiotic (gentamicin) in the bone cement, the rates of infection after the surgical procedure continue causing serious damage to the hospital and the patient. The main bacteria involved in infections related to orthopedic implants are Pseudomonas aeruginosa, Staphylococcus aureus and Staphylococcus epidermidis. The objective of this study was to evaluate the adhesion and biolfilm formation of the S. aureus, S. epidermidis and P. aeruginosa on the bone cement polymethylmethacrylate (PMMA) with and without antibiotic (gentamicin) from national and international origin, by means scanning electron microscope (SEM) and by culture. Also, quantitatively estimate the viable cells recovered from biofilms formed. Discs of cement were produced from 10.0 mm in diameter and 3.0 mm thick. Strains used were Pseudomonas aeruginosa - ATCC 27853, Staphylococcus epidermidis - ATCC 12228 e Staphylococcus aureus - ATCC 25932. For this study we used coupons cement of national origin (Baumer, CMM and biomechanics) and international (BIOMET with gentamicin, BIOMET without gentamicin and SIMPLEX). Biofilms were produced in vitro from the inoculation of bacterial suspension (108 Colony-Forming Units/mL) in Tryptic Soy Broth and incubated for the time periods of 1, 6, 24, 48 and 72 hours. After the incubation periods of the coupons they were removed from the medium culture, washed, sonicated and serial dilutions of supernatant taken (\'10 POT.-1\' a \'10 POT.-5\'). Next, the coupons were prepared for observation by SEM. The results of SEM showed adherent cocci bacilli, and adhered to each other form a biofilm. For P. aeruginosa: the couting of viable cells on average (CFU/mL) were 2,8 \'+ OU -\' 1,7 x \'10 POT.6\' (BAUMER), 1,7 \'+ OU -\' 0,9 x \'10 POT.6\' (BIOMECANICA), 1,7 \'+ OU -\' 0,7 x \'10 POT.6\' (CMM), 1,6 \'+ OU -\' 0,7 x \'10 POT.6\' (BIOMET sem gentamicina), 6,0 \'+ OU -\' 5,5 x \'10 POT.4\' (BIOMET com gentamicina) e 1,9 \'+ OU -\' 0,9 x \'10 POT.6\' (SIMPLEX); para S. epidermidis: 1,3 \'+ OU -\' 0,1 x \'10 POT.6\' (BAUMER), 1,5 \'+ OU -\' 0,2 x \'10 POT.6\' (BIOMECANICA), 2,3 \'+ OU -\' 1,7 x \'10 POT.6\' (CMM), 1,5 \'+ OU -\' 0,7 x \'10 POT.6\' (BIOMET sem gentamicina), 1,5 \'+ OU -\' 0,2 x \'10 POT.6\' (BIOMET com gentamicina) e 1,2 \'+ OU -\' 0,1 x \'10 POT.6\' (SIMPLEX); para S. aureus: 1,7 \'+ OU -\' 0,8 x \'10 POT.6\' (BAUMER), 1,6 \'+ OU -\' 0,7 x \'10 POT.6\' (BIOMECANICA), 1,4 \'+ OU -\' 0,6 x \'10 POT.6\' (CMM), 1,1 \'+ OU -\' 0,5 x \'10 POT.6\' (BIOMET sem gentamicina), 3,0 \'+ OU -\' 6,0 x \'10 POT.5\' (BIOMET com gentamicina) e 1,3 \'+ OU -\' 0,6 x \'10 POT.6\' (SIMPLEX), respectively. The data showed that of polymethylmethacrylate bone cement with and without gentamicin did not prevent the adhesion of Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus aureus and formation of biofilms, as demonstrated by SEM. In conclusion, this is risk factor for infections.
45

Étude des propriétés physico-chimiques et biologiques de ciments biomédicaux à base de carbonate de calcium : apport du procédé de co-broyage / Study of physico-chemical and biological properties of biomedical calcium carbonate based cements : contribution of the co-grinding process

Tadier, Solène 26 November 2009 (has links)
L'implantation de matériaux pour reconstruction osseuse par des techniques chirurgicales peu invasives nécessite des substituts osseux synthétiques, résorbables, injectables et radioopaques. C'est pourquoi le contrôle des propriétés de ces matériaux est primordial. Dans ce contexte, ce travail s'intéresse à la formulation de deux ciments, l'un uniquement à base de carbonate de calcium, le second composé d'un mélange de carbonate de calcium et de phosphate de calcium en quantités égales. Le traitement des phases solides pulvérulentes de ces deux ciments par les procédés de broyage et de co-broyage a été étudié. Ces procédés permettent entre autres de diminuer la taille moyenne des particules. Un mélange intime et homogène entre les constituants de la phase solide est obtenu grâce au co-broyage et les propriétés des ciments sont très significativement améliorées. Le temps de prise est diminué et l'injectabilité de la pâte est fortement augmentée (facteur 100). Cette dernière propriété a pu être évaluée grâce à la mise au point d'un dispositif et d'un protocole de mesure adaptés à un analyseur de texture. Dans le but de visualiser par radiographie aux rayons X l'introduction du ciment injectable dans le site osseux à réparer, du strontium a été introduit en tant qu'agent de contraste radio-opacifiant. Deux voies d'ajout à la formulation du ciment ont été étudiées : la première sous forme de SrCO3 dans la phase solide, la seconde sous forme de SrCl2 dans la phase liquide. Les études réalisées montrent que le co-broyage de la phase solide contenant du SrCO3 est intéressant pour homogénéiser la dispersion de l'agent de contraste et ainsi optimiser la quantité de strontium à incorporer pour atteindre le niveau de radio-opacité requis par la norme en vigueur. De plus, il a été observé que l'ajout de SrCl2 dans la phase liquide rend la pâte plus visqueuse et diminue son injectabilité. Par ailleurs, l'étude de la dissolution de ces ciments à pH physiologique a révélé une libération lente et prolongée du strontium. Enfin, des tests cellulaires in-vitro ont été réalisés sur ces ciments ; ils mettent en évidence l'excellent comportement de cellules ostéoprogénitrices vis-à-vis de ces formulations de ciment ainsi que l'intérêt d'utiliser le sel de SrCO3 plutôt que de SrCl2. La dernière partie de ce travail concerne l'étude de la cristallisation de l'aragonite, variété polymorphe du carbonate de calcium, en présence d'ions phosphate, connus pour inhiber la cristallisation du CaCO3. Grâce à une modélisation à l'aide de la technique de croissance cristalline à composition constante permettant de se placer dans des conditions proches de celles de la prise du ciment uniquement à base de carbonate de calcium in-vivo, il a été montré que la présence d'ions phosphate, même en très faible quantité (concentration &lt; 0,5 µM) diminue à la fois la vitesse de germination et la vitesse de croissance cristalline de l'aragonite. L'ensemble de ces travaux contribue à l'optimisation des propriétés de ces ciments biomédicaux et à mieux appréhender leur comportement que ce soit au moment de leur implantation in-vivo ou de leur évolution et suivi post-opératoires. D'un point de vue fondamental, ces travaux pluridisciplinaires menés dans des conditions modèles in-vitro mais également dans le cadre d'une expérimentation in-vivo ont mis en évidence l'intérêt de confronter ces deux approches pour identifier et comprendre les phénomènes et les réactions impliqués lors de la prise des ciments à base de carbonate de calcium in-vitro et in-vivo. / Implantation of bone substitute materials using minimally invasive surgical techniques requires specific properties for the material including resorbability, injectability and adequate radio-opacity. The control of such properties of the material is of prime importance to meet a surgeon's requirements. In this context, this study deals with two different mineral cements: the first one is only composed of calcium carbonate phases and the second one is a mixture of equal amount of calcium phosphate and calcium carbonate phases. An original methodology involving complementary analytical techniques was implemented to thoroughly investigate the grinding mechanism of separated or mixed reactive powders constituting the solid phase and its effects on cement reactivity and properties. We show that co-grinding the solid phase decreases the mean size of the particles and favours both a homogeneous mixing and good contact between the components, leading to a decrease in the setting time. We also set two original protocols designed to evaluate paste injectability and phase separation during paste extrusion. Co-grinding leads to synergistic positive effects on cement injectability and radio-opacity. It allows maintaining a low and constant load during the extrusion of paste, which composition remains constant. Moreover, the cement's mechanical properties can be enhanced by lowering the L/S ratio because of the lower plastic limit. To be able to follow in situ the injection of the bone cement using X-ray radiography, strontium has been introduced as a contrast agent in the cement composition. Two different routes have been investigated: SrCO3 has been added to the solid phase or SrCl2 has been dissolved in the liquid phase. We show that co-grinding process permits to homogenise strontium distribution in the cement allowing us to optimise the minimum amount of strontium to add into the cement paste to reach the radio-opacity required by ISO 9917-1 standard. Moreover, adding SrCl2 in the liquid phase makes the cement paste more viscous and diminishes its injectability. Release tests performed on Sr-loaded cements show a sustained release of strontium at 37°C and pH 7.4. Finally, in-vitro cell tests have shown the excellent behaviour of osteoprogenitor cells, especially on cements including SrCO3. The last part of this work deals with the study of the crystallization of aragonite CaCO3 in the presence of phosphate ions, naturally present in biological fluids, to better understand the setting ability of calcium carbonate cements in-vivo. Using the constant composition crystal growth technique, we show that the presence of phosphate ions, even in very low amount (concentration &lt; 0.5 µM) diminishes both the nucleation and the crystal growth rates of aragonite. This work contributes to the optimization of the properties of calcium carbonate-based cements and a better understanding and control of their behaviours during implantation and their evolution in-vivo. From a fundamental point of view, this multidisciplinary work performed in model conditions in-vitro and completed by preliminary in-vivo experiments have underlined the interest in combining these two approaches to identify and understand the phenomena and the chemical reactions involved during the setting of biomedical cements.
46

Stereocomplex poly (methyl methacrylate) fibers and self-reinforced composites and structural color of butterflies and beetles - characterization, replication and mimicry

Crne, Matija 12 May 2009 (has links)
Stereocomplex poly(methyl methacrylate) (PMMA) fibers for the purpose of reinforcing PMMA materials were developed. These kinds of composites are known as "self-reinforced" composites. We were successful in producing stereocomplex PMMA fibers with three different methods - wet spinning, gel spinning and electrospinning. Gel spinning and electrospinning produced the most crystalline fibers. Steroecomplex PMMA fibers were further shown to be resistant to high temperature and also to hot monomer solvent during bulk polymerization. We further describe our efforts in characterization, replication and mimicry of structural color features of butterflies and beetles. We have developed a simple method of characterizing the bidirectional reflectance distribution function of microscopic objects such as butterfly wing scales. We used this method to characterize nanometer sized structural color features resulting from the replication of butterfly Morpho rhetenor, mimickry of butterfly Papilio palinurus and also the native structural color features of iridescent beetle Chrysina gloriosa, which were shown to be cholesteric focal conic defects lined on the surface.
47

Entwicklung und Charakterisierung Strontium-modifizierter CaP-Knochenzemente zur Behandlung osteoporotischer Knochendefekte

Schumacher, Matthias 20 January 2015 (has links) (PDF)
Für die Behandlung von Knochendefekten überkritischer Größe stehen seit einigen Jahren zahlreiche resorbierbare Materialien zur Verfügung, die eine Defektheilung bis hin zur vollständigen knöchernen Regeneration erlauben. Im Fall systemischer Knochenerkrankungen, insbesondere im osteoporotischen Knochen, ist jedoch die Selbstheilungskapazität des Gewebes stark eingeschränkt, was neben der Defektbehandlung eine knochenanabole sowie resorptionshemmende Therapie erfordert. Diese kann beispielsweise durch die Gabe von Strontium-haltigen Präparaten erreicht werden, da der duale Wirkmechanismus der Strontium-Ionen zu vermehrter Knochenneubildung bei gleichzeitig verminderter Knochenresorption führt. Ziel der vorliegenden Arbeit war die Entwicklung eines Strontium-haltigen Knochenzements, welcher eine Freisetzung von Strontium-Ionen spezifisch im jeweiligen Knochendefekt und somit eine lokale Stimulation der Knochenneubildung ermöglicht. Basierend auf einem etablierten Calciumphosphat-Knochenzement wurden Strontium-haltige Zementvarianten hergestellt und ausgiebig charakterisiert. Im Gegensatz zu den meisten bislang verfolgten Methoden konnten Zemente mit deutlich verbesserten mechanischen Eigenschaften hergestellt werden, welche weiterhin Strontium-Ionen in physiologisch relevanten Konzentrationen freisetzen. Durch Zellkulturuntersuchungen an humanen Zellen sowohl der osteoblastären- als auch osteoklastären Linie konnte eine Stimulation der für den Knochenaufbau verantwortlichen Zellen sowie eine Hemmung der den Knochen resorbierenden Zellen durch die entwickelten Zemente nachgewiesen werden.
48

Évaluation de la stabilité primaire d'une greffe ostéochondrale autologue stabilisée au moyen d'un ciment ostéoconducteur résorbable

Kiss, Marc-Olivier 12 1900 (has links)
L’objectif de cette étude est de vérifier si un ciment ostéoconducteur résorbable utilisé comme technique de fixation de greffons ostéochondraux permet d'obtenir une stabilité initiale supérieure à celle obtenue avec la technique de mosaicplastie originalement décrite. Il s’agit d’une étude biomécanique effectuée sur des paires de fémurs cadavériques bovins. Pour chaque paire de fémurs, des greffons ostéochondraux autologues ont été insérés et stabilisés au moyen d’un ciment biorésorbable (Kryptonite, DRG inc.) sur un fémur alors qu’au fémur controlatéral, les greffons ont été implantés par impaction selon la technique usuelle de mosaicplastie. Des greffons uniques ainsi que des greffons en configuration groupée ont été implantés et soumis à une évaluation biomécanique. Les charges axiales nécessaires pour enfoncer les greffons de 1, 2 et 3 mm ont été comparées en fonction de la technique de stabilisation utilisée, ciment ou impaction, pour chaque configuration de greffons. Les résultats démontrent que les greffons ostéochondraux cimentés uniques et groupés ont une stabilité initiale supérieure à celle de greffons non cimentés sur des spécimens cadavériques bovins. L’obtention d’une plus grande stabilité initiale par cimentation des greffons ostéochondraux pourrait permettre une mise en charge précoce post-mosaicplastie et mener à une réhabilitation plus rapide. / The objective of this project is to compare the primary stability of osteochondral autografts stabilized with a resorbable osteoconductive bone cement to that of bottomed press fit grafts inserted according to the original mosaicplasty technique. Biomechanical testing was conducted on pairs of cadaveric bovine femurs. For each femoral pair, osteochondral grafts were inserted and stabilized with an osteoconductive bone cement (Kryptonite, DRG inc.) on one bone whereas on the controlateral femur, grafts were inserted in a press fit fashion. Grafts were inserted in 2 different configurations, single grafts as well as groups of 3 adjacent grafts, and submitted to biomechanical testing. Axial loads needed to sink the grafts to 1, 2 and 3 millimeters below cartilage level were recorded and compared according to the fixation technique, cement or press-fit impaction, for each graft configuration. According to those results, cemented osteochondral autografts appear more stable than press fit grafts for both single and 3-in-a-row configurations. Using such a cementation technique could potentially prevent the initial loss of stability that has been shown to occur with osteochondral grafts in the post-operative period, allowing patients to perform early weight bearing and rehabilitation.
49

Injectable Biomaterials for Spinal Applications

López, Alejandro January 2014 (has links)
The use of injectable biomaterials is growing as the demands for minimally invasive procedures, and more easily applicable implants become higher, but their availability is still limited due to the difficulties associated to their design. Each year, more than 700,000 vertebral compression fractures (VCF’s) are reported in the US and 500,000 VCF’s in Europe due to primary osteoporosis only. VCF’s can compromise the delicacy of the spinal canal and also cause back pain, which affects the patient’s quality of life. Vertebroplasty was developed in the 80’s, and has proven to be a safe minimally invasive procedure that can, quickly and sustainably, relieve the pain in patients experiencing VCF’s. However, biomaterials for vertebroplasty still have limitations. For instance, ceramic bone cements are difficult to distinguish from the bone using X-ray techniques. On the other hand, acrylic bone cements may cause adjacent vertebral fractures (AVF’s). Large clinical studies have indicated that 12 to 20% vertebroplasty recipients developed subsequent vertebral fractures, and that 41 to 67% of these, were AVF’s. This may be attributed to the load shifting and increased pressure on the adjacent endplates reached after vertebroplasty with stiff cements. The primary aim of this thesis was to develop better injectable biomaterials for spinal applications, particularly, bone cements for vertebroplasty. Water-soluble radiopacifiers were first investigated to enhance the radiopacity of resorbable ceramic cements. Additionally, different strategies to produce materials that mechanically comply with the surrounding tissues (low-modulus bone cements) were investigated. When a suitable low-modulus cement was produced, its performance was evaluated in both bovine bone, and human vertebra ex vivo models. In summary, strontium halides showed potential as water-soluble radiocontrast agents and could be used in resorbable calcium phosphates and other types of resorbable biomaterials. Conversely, linoleic acid-modified (low-modulus) cements appeared to be a promising alternative to currently available high-modulus cements. It was also shown that the influence of the cement properties on the strength and stiffness of a single vertebra depend upon the initial bone volume fraction, and that at low bone volume fractions, the initial mechanical properties of the vertebroplasty cement become more relevant. Finally, it was shown that vertebroplasty with low-modulus cements is biomechanically safe, and could become a recommended minimally invasive therapy in selected cases, especially for patients suffering from vertebral compression fractures due to osteoporosis.
50

Étude des propriétés physico-chimiques et biologiques de ciments biomédicaux à base de carbonate de calcium : apport du procédé de co-broyage / Study of physico-chemical and biological properties of biomedical calcium carbonate based cements : contribution of the co-grinding process

Tadier, Solène 26 November 2009 (has links)
L'implantation de matériaux pour reconstruction osseuse par des techniques chirurgicales peu invasives nécessite des substituts osseux synthétiques, résorbables, injectables et radioopaques. C'est pourquoi le contrôle des propriétés de ces matériaux est primordial. Dans ce contexte, ce travail s'intéresse à la formulation de deux ciments, l'un uniquement à base de carbonate de calcium, le second composé d'un mélange de carbonate de calcium et de phosphate de calcium en quantités égales. Le traitement des phases solides pulvérulentes de ces deux ciments par les procédés de broyage et de co-broyage a été étudié. Ces procédés permettent entre autres de diminuer la taille moyenne des particules. Un mélange intime et homogène entre les constituants de la phase solide est obtenu grâce au co-broyage et les propriétés des ciments sont très significativement améliorées. Le temps de prise est diminué et l'injectabilité de la pâte est fortement augmentée (facteur 100). Cette dernière propriété a pu être évaluée grâce à la mise au point d'un dispositif et d'un protocole de mesure adaptés à un analyseur de texture. Dans le but de visualiser par radiographie aux rayons X l'introduction du ciment injectable dans le site osseux à réparer, du strontium a été introduit en tant qu'agent de contraste radio-opacifiant. Deux voies d'ajout à la formulation du ciment ont été étudiées : la première sous forme de SrCO3 dans la phase solide, la seconde sous forme de SrCl2 dans la phase liquide. Les études réalisées montrent que le co-broyage de la phase solide contenant du SrCO3 est intéressant pour homogénéiser la dispersion de l'agent de contraste et ainsi optimiser la quantité de strontium à incorporer pour atteindre le niveau de radio-opacité requis par la norme en vigueur. De plus, il a été observé que l'ajout de SrCl2 dans la phase liquide rend la pâte plus visqueuse et diminue son injectabilité. Par ailleurs, l'étude de la dissolution de ces ciments à pH physiologique a révélé une libération lente et prolongée du strontium. Enfin, des tests cellulaires in-vitro ont été réalisés sur ces ciments ; ils mettent en évidence l'excellent comportement de cellules ostéoprogénitrices vis-à-vis de ces formulations de ciment ainsi que l'intérêt d'utiliser le sel de SrCO3 plutôt que de SrCl2. La dernière partie de ce travail concerne l'étude de la cristallisation de l'aragonite, variété polymorphe du carbonate de calcium, en présence d'ions phosphate, connus pour inhiber la cristallisation du CaCO3. Grâce à une modélisation à l'aide de la technique de croissance cristalline à composition constante permettant de se placer dans des conditions proches de celles de la prise du ciment uniquement à base de carbonate de calcium in-vivo, il a été montré que la présence d'ions phosphate, même en très faible quantité (concentration &lt; 0,5 µM) diminue à la fois la vitesse de germination et la vitesse de croissance cristalline de l'aragonite. L'ensemble de ces travaux contribue à l'optimisation des propriétés de ces ciments biomédicaux et à mieux appréhender leur comportement que ce soit au moment de leur implantation in-vivo ou de leur évolution et suivi post-opératoires. D'un point de vue fondamental, ces travaux pluridisciplinaires menés dans des conditions modèles in-vitro mais également dans le cadre d'une expérimentation in-vivo ont mis en évidence l'intérêt de confronter ces deux approches pour identifier et comprendre les phénomènes et les réactions impliqués lors de la prise des ciments à base de carbonate de calcium in-vitro et in-vivo. / Implantation of bone substitute materials using minimally invasive surgical techniques requires specific properties for the material including resorbability, injectability and adequate radio-opacity. The control of such properties of the material is of prime importance to meet a surgeon's requirements. In this context, this study deals with two different mineral cements: the first one is only composed of calcium carbonate phases and the second one is a mixture of equal amount of calcium phosphate and calcium carbonate phases. An original methodology involving complementary analytical techniques was implemented to thoroughly investigate the grinding mechanism of separated or mixed reactive powders constituting the solid phase and its effects on cement reactivity and properties. We show that co-grinding the solid phase decreases the mean size of the particles and favours both a homogeneous mixing and good contact between the components, leading to a decrease in the setting time. We also set two original protocols designed to evaluate paste injectability and phase separation during paste extrusion. Co-grinding leads to synergistic positive effects on cement injectability and radio-opacity. It allows maintaining a low and constant load during the extrusion of paste, which composition remains constant. Moreover, the cement's mechanical properties can be enhanced by lowering the L/S ratio because of the lower plastic limit. To be able to follow in situ the injection of the bone cement using X-ray radiography, strontium has been introduced as a contrast agent in the cement composition. Two different routes have been investigated: SrCO3 has been added to the solid phase or SrCl2 has been dissolved in the liquid phase. We show that co-grinding process permits to homogenise strontium distribution in the cement allowing us to optimise the minimum amount of strontium to add into the cement paste to reach the radio-opacity required by ISO 9917-1 standard. Moreover, adding SrCl2 in the liquid phase makes the cement paste more viscous and diminishes its injectability. Release tests performed on Sr-loaded cements show a sustained release of strontium at 37°C and pH 7.4. Finally, in-vitro cell tests have shown the excellent behaviour of osteoprogenitor cells, especially on cements including SrCO3. The last part of this work deals with the study of the crystallization of aragonite CaCO3 in the presence of phosphate ions, naturally present in biological fluids, to better understand the setting ability of calcium carbonate cements in-vivo. Using the constant composition crystal growth technique, we show that the presence of phosphate ions, even in very low amount (concentration &lt; 0.5 µM) diminishes both the nucleation and the crystal growth rates of aragonite. This work contributes to the optimization of the properties of calcium carbonate-based cements and a better understanding and control of their behaviours during implantation and their evolution in-vivo. From a fundamental point of view, this multidisciplinary work performed in model conditions in-vitro and completed by preliminary in-vivo experiments have underlined the interest in combining these two approaches to identify and understand the phenomena and the chemical reactions involved during the setting of biomedical cements.

Page generated in 0.3161 seconds