• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 42
  • 21
  • 8
  • 5
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 191
  • 102
  • 65
  • 47
  • 39
  • 35
  • 32
  • 25
  • 25
  • 25
  • 23
  • 21
  • 21
  • 20
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Achados audiológicos de indivíduos com a síndrome G/BBB / Hearing findings in subjects with G / BBB syndrome

Cassab, Tatiana Vialogo 12 November 2010 (has links)
Objetivo: Investigar a função auditiva, periférica e central, em pacientes com o diagnóstico da síndrome G/BBB, quanto à ocorrência ou não de perda auditiva e, a condução nervosa auditiva periférica e central, em nível do tronco encefálico. Modelo: Análise prospectiva descrevendo os achados audiológicos em indivíduos com a síndrome G/BBB. Local de Execução: Setor de Genética, HRAC-USP. Participantes: 14 pacientes na faixa etária de 7 a 34 anos, do gênero masculino. Variáveis: Limiares audiométricos em decibels nas frequências de 0,25 a 8 kHz nas duas orelhas, tipo de curva timpanométrica nas duas orelhas, latências absolutas das ondas I, III e V; latências interpicos I-V, III-V e I-III e diferença interaural da onda V do PEATE, em milissegundos, para cada orelha. Resultados: Limiares audiométricos normais em 12 (66,7%) pacientes da amostra, e 2 (33,3%) com perda auditiva, sendo 1 do tipo condutiva e 1 neurossensorial. Quanto aos resultados do PEATE, foram encontrados: latências absolutas da onda I dentro dos padrões de normalidade em todos os pacientes, aumento das latências absolutas da onda III e V em 2 e 6 pacientes respectivamente; e as latências interpicos I-III, III-V e I-V se apresentaram aumentadas em 4, 3 e 8 pacientes respectivamente. Conclusões: Frente aos resultados obtidos podemos concluir que pacientes com a síndrome G/BBB podem apresentar perdas auditivas periféricas, condutivas e neurossensoriais, entretanto, não há subsídios para afirmar que as mesmas são em decorrência da síndrome ou da associação com a fissura de palato. Há evidências de comprometimento das vias auditivas centrais em nível do tronco encefálico, embora as alterações estruturais do SNC relatadas nesta síndrome não estejam relacionadas diretamente com as vias auditivas. Estudos com enfoque no perfil audiológico desta população com exames de imagem são necessários para maior clareza dos achados clínicos. / Objective: To investigate the peripheral and central auditory function in patients with G/BBB syndrome and the occurrence of hearing loss in these patients. Model: Prospective study describing the audiological findings in subjects with G/BBB syndrome. Setting: Genetics Department, HRAC-USP. Participants: 14 male patients aged from 7 to 34 years. Variables: Audiometric thresholds in decibels at frequencies of 0.25 to 8 KHz in both ears, tympanometric curve in both ears, absolute latencies of waves I, III and V, interpeak latencies I-V, III-V and I-III and wave V interaural difference of ABR, in milliseconds, for each ear. Results: Normal audiometric thresholds were found in 12 (66.7%) patients, 2 (33.3%) had hearing loss, one type conductive and one sensorioneural. ABR results were: absolute latencies of wave I within normal limits in all patients, an increase of absolute latencies of wave III and V in 2 and 6 patients respectively, and interpeak latencies I-III, IV and V were increased in 4, 3 and 8 patients respectively. Conclusions: Patients with G/BBB syndrome may have peripheral conductive or sensorineural hearing loss; however, there are no subsidies to attribute the etiology to the syndrome itself or to the presence of cleft palate, which was found in all patients. There is evidence of central auditory pathways involvement in the brainstem level, although the structural CNS abnormalities reported in this syndrome are not directly related to the auditory pathways evaluated. Studies focusing on the audiological profile of this population with imaging studies are recommended.
122

Desenvolvimento de um dispositivo capaz de registrar e analisar potenciais evocados auditivos nos domínios do tempo e das freqüências / Development of a device capable of recording and analyzing auditory evoked potentials in the time and frequency domain

Menezes, Pedro de Lemos 02 October 2008 (has links)
A integridade da via auditiva e a investigação do respectivo limiar eletrofisiológico podem ser avaliadas por meio da observação, no domínio do tempo, dos potenciais evocados auditivos de tronco encefálico. Atualmente, nova técnica de análise dos potenciais evocados auditivos, no domínio das freqüências, tem sido utilizada para uma observação particular desses limiares. Assim, com a aplicação da transformada rápida de Fourier, é possível realizar a análise das freqüências comprometidas na audição, de maneira eficiente e rápida. O objetivo com este trabalho, então, foi desenvolver, caracterizar e realizar testes preliminares com um dispositivo único capaz de avaliar os potenciais evocados auditivos nos dois domínios, por meio de uma placa de som, que ainda não havia sido implementada para tal fim. Desse modo, foi produzido um aparelho capaz de registrar sinais biológicos da ordem de 0,5 ?V. Após a caracterização e o estudo simulado, foram conduzidos testes-piloto com doze seres humanos, ouvintes normais (n = 24 orelhas), divididos em dois grupos com o mesmo número de participantes. No grupo 1, os potenciais evocados auditivos de tronco encefálico adquiridos por meio de um instrumento padrão-ouro e de instrumento desenvolvido foram comparados entre si. Em seguida, os achados foram relacionados com o exame no domínio das freqüências formatado no novo aparelho. O grupo 2 foi submetido à avaliação dos potenciais miogênicos vestibulares, também com os dois instrumentos, e suas latências absolutas comparadas. Os resultados demonstraram não haver diferenças significativas entre os dois instrumentos para as amplitudes e latências do potencial evocado auditivo de tronco encefálico. Constatou-se, ainda, que as ondas presentes no domínio do tempo davam respostas equivalentes no domínio das freqüências. Por fim, também não foram encontradas diferenças significativas entre os dois aparelhos para as latências do potencial miogênico vestibular. / The integrity of the auditory pathway and the investigation of the respective electrophysiological threshold can be assessed by observation, in the time domain, of brainstem auditory evoked potentials. This assessment is usually evoked by clicks, which have a wide acoustic spectrum, and consequently serious limitations with respect to frequency specificity, in determining electrophysiological thresholds. New techniques for analyzing auditory evoked potentials in the frequency domain are currently being used for a closer observation of these thresholds. Thus, by applying the fast Fourier transform, one can analyzed the compromised auditory frequencies efficiently and rapidly. This method, on the other hand, does not investigate the integrity of specific auditory pathway structures, as the other method does. Although both types of assessment require similar biological amplifier architecture and are, to a certain extent, complementary, they are performed with two distinct devices. The first, which makes the observation in the time domain, is quite well known and several manufacturers have been producing it for a long time. The second, which inspects the potentials in the frequency domain, was introduced into the market only a few years ago. The aim of this study, therefore, was to develop, characterize and conduct preliminary tests with a single device capable of evaluating the auditory evoked potentials in both domains, by means of a sound card that had not been previously used for this purpose. Thus, a device was produced with biological amplifiers, filters, electrical protection apparatus and a logic control system capable of recording biological signals around 0.5 µV. After characterization and the simulated study, pilot tests were carried out with 12 normal- hearing subjects (n = 24 ears), allocated to two groups of 6 participants. In group 1, we observed the latencies and amplitudes of waves I, III and V of the brainstem auditory evoked potentials, using a gold standard instrument and a developed instrument and later compared them. The findings were then correlated to those of the frequency domain examination formatted on the new device. Group 2 was submitted to an assessment of components p13 and n23 of the vestibular myogenic potentials to observe the most delayed biological signals, also with both instruments, and their absolute latencies were compared. The results showed no significant differences between the two instruments for the amplitudes (p = 0.379; p = 0.301; p = 0.605, waves I, III and V, respectively) and latencies (p = 0.381; p = 0.140; p = 0.255) of the brainstem auditory evoked potentials. It was also found that the waves present in the time domain gave equivalent responses in the frequency domain. Finally, no significant differences were observed between the two devices for the absolute latencies of components p13 and n23 of the vestibular myogenic potentials, with p values of 0.102 and 0.078, respectively. Thus, it was concluded that the new instruments were efficient for the functions tested.
123

Potencial evocado auditivo de tronco encefálico em gerbils submetidos à isquemia e sepse / Auditory brainstem response in gerbils submitted to ischemia and sepsis

Lima, Janaina Patrício de 23 May 2012 (has links)
Introdução: O Acidente Vascular Cerebral do tipo isquêmico é um quadro clínico que afeta milhares de pessoas no mundo. Como resultado dessa injúria observamos morte neuronal, e no decorrer natural de recuperação, o indivíduo pode desenvolver a sepse. A sepse é uma resposta inflamatória sistêmica que pode levar o indivíduo a morte. No seu desenvolvimento há a produção de diversas citocinas que caracterizam o processo inflamatório no organismo. Para avaliar as condições clínicas de um paciente com esse quadro o Potencial Evocado Auditivo de Tronco Encefálico (PEATE) pode ser útil,uma vez que ele não é um procedimento invasivo, sua técnica é rápida e pode ser feita à beira do leito. Porém, por outro lado, o PEATE pode ser sensível ao uso de alguns anestésicos. Objetivos: Fazer análise das citocinas IL-6, IL-10 e TNF- no decorrer da sepse; verificar os valores de latência do PEATE em gerbils submetidos à isquemia e sepse; e verificar a influência do anestésico ketamina associado à xilazina nos valores do PEATE desses animais. Método: Foram coletados os PEATEs de 72 gerbils machos adultos que foram divididos em 6 grupos, a saber: controle, sepse, isquemia, sham, isquemia com sepse e sham com sepse. Para a indução de sepse foi aplicado Lipopolissacarídeo (LPS) intraperitoneal nos gerbils. Os animais foram anestesiados antes das coletas com ketamina associada à xilazina, seus PEATEs foram coletados antes de qualquer procedimento (coleta base), após isquemia e 2, 4, 8 e 24 horas após a aplicação de LPS. Foi avaliada a latência absoluta da onda V, e os valores foram comparados intra e intergrupos. As citocinas IL-6, IL-10 e TNF- foram analisadas e comparadas em cada grupo estudado. Resultados: Foi observado aumento das citocinas IL-6, IL-10 e TNF- no decorrer da sepse. Houve diferença estatisticamente significante nos grupos submetidos à sepse no valor da latência da onda V em relação aos demais grupos. Observou-se, também, aumento da latência da onda V após a aplicação sucessiva do anestésico ketamina/xilazina em todos os grupos estudados. Conclusão: Houve aumento dos níveis das citocinas IL-6, IL-10 e TNF- nos animais que sofreram aplicação de LPS, revelando uma alteração de expressão gênica de moléculas pró (IL-6 e TNF-) e anti-inflamatória (IL-10) no decorrer da sepse.O PEATE se mostrou sensível a sepse com aumento de latência da onda V no desenvolver da doença no modelo experimental utilizado. O uso de Ketamina associada à xilazina influenciou o resultado do PEATE, aumentando o valor de latência absoluta da onda V do PEATE / Introduction: The Cerebrovascular Accident of ischemic type is a clinical condition affecting thousands of people around the world. As a result of this injury we observe neuronal death, and along the natural course of recovery individuals may develop sepsis. Sepsis is a systemic inflammatory response that may lead to death. Along its development, several cytokines are produced that characterize the inflammatory process on the body. To assess the clinical conditions of a patient with this condition the Auditory Brainstem Response (ABR) may be useful, as it is not an invasive procedure, it is fast to perform, and may be done at the patients bedside. On the other hand, the ABR may be sensitive to the use of some anesthetics. Objectives: To perform an analysis of the IL-6, IL-10 and TNF- cytokines in the course of sepsis; to verify the ABR latency values in gerbils submitted to ischemia and sepsis; and to verify the influence of the ketamine/xylazine anesthetic on the ABR values in these animals. Method: ABRs were collected for 72 adult male gerbils divided into 6 groups, namely: control, sepsis, ischemia, sham, ischemia with sepsis and sham with sepsis. For induction of sepsis, intraperitoneal lipopolysaccharide (LPS) was injected into the gerbils. The animals were anesthetized prior to the collections with ketamine/xylazine, theirs ABRs were collected before any procedure (base collection), after ischemia and 2, 4, 8 and 24 hours after the LPS injection. The absolute latency of the V wave was assessed, and values were compared within and among groups. The IL-6, IL-10 and TNF- cytokines were analyzed and compared in each study group. Results: An increase was observed in IL-6, IL-10 and TNF- cytokines in the course of sepsis. There was a statistically significant difference in the groups submitted to sepsis in the value of the V wave latency compared to the other groups. An increase in the V wave latency was also observed after successive injection of the ketamine/xylazine anesthetic in all study groups. Conclusion: There was an increase in the levels of IL-6, IL-10 and TNF- cytokines in the animals injected with LPS, revealing a change of the gene expression of the pro- (IL-6 and TNF-) and anti-inflammatory (IL-10) molecules in the course of sepsis. The ABR proved to be sensitive to sepsis with an increase of the V wave latency in the course of the disease on the experimental model used. The use of ketamine/xylazine influenced the results of the ABR, increasing the absolute latency value for the V wave of the ABR
124

Influencia da taxa de repetição do estimulo clique na latência e amplitude do potencial evocado auditivo de tronco encefálico

Bento, Daniela Veronese 06 February 2012 (has links)
Made available in DSpace on 2016-04-27T18:11:55Z (GMT). No. of bitstreams: 1 Daniela Veronese Bento.pdf: 1507917 bytes, checksum: 505321b79ebbf90c862cd111179b4352 (MD5) Previous issue date: 2012-02-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / INTRPDUCTION: Many different rates for ABR can be used to sensitize the exam. However, due to possible differences that can occur in the latencies and amplitudes when using ABR, it is necessary to carry out research to support the audiological diagnosis and help the clinical decision-making process. AIM: To study the influences at the two different repetition stimulus rates in the ABR in adults, neonates and premature infants. METHOD: ten normal-hearing neonates (GI), adults (GII) and premature infants (GIII) were subjected to ABR registration by air with repetition rates from 27.7 to 61.1 clicks per second (intensities: 80, 60, 40 and 20 dBHL). RESULTS: The arithmetic means and medians showed adjacent values for each combination of repetition rate and groups, which suggests that the distribution of the variables shows symmetry. Nevertheless, at 80 dBHL, the repetition rate of 61.1 clicks per second attained an absolute latency in waves I, II and V augmented in the groups GI and GIII (P=0.003, P=0* and P=0, respectively) and the amplitude in waves III and V reduced in the GI and GII (P=0.014 and P=0*). Wave III had the most reduced amplitude with a rarefied polarity (P=0.014). Moreover, the latency time during interpeak intervals I-III were higher for GI and GIII (P=0.0035); during III-V were higher for GIII (P=0*) and during I-V were higher for GI (P=0*). At 60 dBHL, the latency was higher for GI and GIII, -at 61.1 clicks per second in the three groups (P=0+)-, and the amplitude was more reduced for GI and GII (P=0,001). At 40 dBHL, two repetition rates attained a higher latency and reduced amplitude for GI and GII (P=0,005 and P=0,001, respectively); however, the three groups presented a higher latency time at 61.1 clicks per second (P=0,005). At 20 dBHL, the latency was higher for GII and GIII - 61.1 clicks per second (p=0,020)-, and the amplitude was smaller for GI and GIII (P=0,002). The exam length was higher - 27.7 click per second (P=0*)- in the three groups. CONCLUSION: Despite the latency increase and amplitude reduction, the method of raising the repetition rate of the acoustic stimuli to register electrophysiological hearing responses can be incorporated to sensitize the exam and decrease its duration / INTRODUÇÃO: O estímulo clique é utilizado para avaliar a integridade do sistema auditivo e verificar a sincronia neural. No registro do Potencial Evocado Auditivo de Tronco Encefálico (PEATE) podem ser utilizadas diferentes taxas de apresentação do clique para sensibilizar o exame. Entretanto, devido a possíveis diferenças que podem ocorrer nas latências e amplitudes no PEATE, faz-se necessária a realização de um estudo que forneça dados normativos, para fundamentar o diagnóstico audiológico e auxiliar na tomada de decisões quanto aos protocolos utilizados na prática clínica. OBJETIVO: Estudar a influência de duas taxas diferentes de repetição do estímulo clique no PEATE, em adultos, neonatos-termo e prematuros. MÉTODO: Dez neonatos-termo (GI), dez adultos (GII) e dez neonatos prétermos (GIII) com audição normal foram submetidos ao registro do PEATE por via aérea nas taxas de repetição de 27.7 e 61.1 cliques/segundo nas intensidades de 80, 60 40 e 20 dBnNA. RESULTADOS: As médias e medianas apresentaram valores próximos para cada combinação de taxa de repetição e grupos, sugerindo que a distribuição das variáveis estudadas apresenta simetria. Entretanto, na intensidade de 80 dBnNA, a taxa de repetição de 61.1 cliques/segundo obteve a latência absoluta das ondas I, III e V aumentada nos grupos GI e GIII (valor P=0,003, valor P=0+ e valor P=0+, respectivamente) e amplitude das ondas III e V reduzida no GI e GII (valor P=0,014 e valor P=0+), sendo que a onda III teve amplitude mais reduzida com a polaridade rarefeita (valor P=0,014). Além disso, o tempo de latência dos intervalos interpicos I-III foi maior para o GI e GIII (valor P=0,035); em III-V foi maior para o GIII (valor P=0+) e em I-V foi maior para o GI (valor P=0+). Em 60 dBnNA, a latência foi maior para GI e GIII, e em 61.1 cliques/segundo nos três grupos (valor P=0+), e a amplitude foi menor para GI e GIII (P=0,001). Em 40 dBnNA, as duas taxas de repetição obtiveram latência maior e amplitude menor em GI e GIII (valor P=0,005 e valor P=0,001, respectivamente); entretanto, os três grupos apresentaram tempo de latência maior em 61.1 cliques/segundo (valor P=0,005). Em 20 dBnNA, a latência foi maior para GII e GIII em 61.1 cliques/segundo (valor P=0,020), e a amplitude foi menor para GI e GIII (valor P=0,002). A média de duração do exame foi maior em 27.7 cliques/segundo (valor P=0+) nos três grupos. CONCLUSÃO: Apesar do aumento da latência e da diminuição da amplitude, o método de elevar a taxa de repetição do estímulo acústico para registrar respostas eletrofisiológicas da audição pode ser incorporado para sensibilizar o exame, investigando a integridade do sistema auditivo e a sincronia neural, com tempo de realização do exame diminuído
125

Triagem auditiva neonatal com potencial evocado auditivo de tronco encefálico automático: a utilização de novas tecnologias

Sena, Taise Argolo 14 February 2012 (has links)
Made available in DSpace on 2016-04-27T18:11:56Z (GMT). No. of bitstreams: 1 Taise Argolo Sena.pdf: 595972 bytes, checksum: 7693a80adc39a593cccdae56ded0102f (MD5) Previous issue date: 2012-02-14 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Introduction: The Automated Auditory Brainstem Response (AABR) is an important tool to make Newborn Hearing Screening. However, some aspects that make it more difficult to exam, like time and intensity of acoustic stimulus, must be taken into consideration. Aim: Analyze the results of Newborn Hearing Screening with Automated Auditory Brainstem Response with new technologies that use the detection method in the frequency domain and stimulus repetition rate at 93Hz. Methodology: The Automated Auditory Brainstem Response was made at 200 newborns (93 female and 107 male), at 30 and 35dBnHL. Subsequently all newborns were submitted to the Auditory Brainstem Response (ABR) Diagnostic Mode, as golden standard test. Results: The sensibility and specificity were calculated through Fisher Exact Test taken into consideration the ABR Diagnostic Mode. The sensibility found at AABR at 35dBnNA was 100% and the specificity was 100%, at the intensity of 30dBnNA the sensibility found was 100% and the specificity was 97.23%. The average time to make the automated exam was 28.3 seconds in the 35 dBnHL and 32.9 seconds in the 30 dBnHL. The time was analyzed considering the state of consciousness of the newborn, based on the Brazelton Scale classification. It was possible to notice that when the newborn was quieter the examination time was quicker. Conclusion: The AABR made at frequency domain with stimulus repetition rate at 93Hz shows high sensibility and specificity, with relative short time to get the results. The state of consciousness influences the execution time of the exam. / Introdução: O Potencial Evocado Auditivo de Tronco Encefálico Automático (PEATE-A) é uma ferramenta importante para realização da Triagem Auditiva Neonatal. Entretanto, alguns aspectos que dificultam a realização do exame, como o tempo e a intensidade do estímulo acústico, devem ser levados em consideração. Objetivos: Analisar os resultados da Triagem Auditiva Neonatal com Potencial Evocado Auditivo de Tronco Encefálico Automático, com novas tecnologias que utilizam método de detecção no domínio da frequência e taxa de repetição do estímulo a 93Hz. Metodologia: O Potencial Evocado Auditivo de Tronco Encefálico Automático foi realizado em 200 neonatos (93 do sexo feminino e 107 do masculino), nas intensidades de 30 e 35dBnNA. Em seguida, todos os neonatos foram submetidos ao exame de Potencial Evocado Auditivo de Tronco Encefálico (PEATE) Modo Diagnóstico, como teste padrão ouro. Resultados: A sensibilidade e especificidade foram calculadas por meio do Teste Exato de Fisher, levando em consideração o resultado do PEATE Modo Diagnóstico. A sensibilidade encontrada para o PEATE-A na intensidade de 35dBnNA foi de 100% e a especificidade de 100%; para a intensidade de 30dBnNA a sensibilidade encontrada foi de 100% e a especificidade, de 97,23%. O tempo médio de realização do exame automático foi de 28,3 segundos para a intensidade de 35 dBnNA e de 32,9 segundos para a intensidade de 30dBnNA. O tempo também foi analisado de acordo com o estado de consciência do neonato, conforme a classificação da Escala de Brazelton. Foi possível observar que quanto mais quieto o neonato, mais rápido o tempo de realização do exame. Conclusão: O PEATE-A realizado no domínio da frequência com taxa de repetição em 93Hz apresenta alta sensibilidade e especificidade, com tempo consideravelmente curto para a determinação da resposta. O estado de consciência influencia no tempo de execução do exame
126

Protocolos de triagem auditiva neonatal por meio de emissões otoacústicas evocadas por estímulo transiente e potencial evocado auditivo de tronco encefálico: uma revisão integrativa / Protocols for newborn hearing screening in transient evoked otoacoustic emissions and auditory brainstem evoked potential: the integrative review

Nobre, Raquel Alves 16 September 2014 (has links)
Made available in DSpace on 2016-04-27T18:12:05Z (GMT). No. of bitstreams: 1 Raquel Alves Nobre.pdf: 1069573 bytes, checksum: b8d1295a1b5de37c7e8a3aac4652d769 (MD5) Previous issue date: 2014-09-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The Universal Newborn Hearing Screening (UNSH) aims to provide early diagnosis in newborns. The procedure uses objective measures such as the Transient Evoked Otoacustic Emissions (TEOAEs) and the Auditory Brainstem Response (ABR). Different stages and protocols are broadly used in TANU, and that may change the values of passes and fails of each program. Purpose: To study the rate of passes and fails in the protocols and stages that are used at TANU, which were performed using electroacoustic (TEOAEs) and electrophysiological (ABR) procedures through an integrative review. Methods: Type of study: An integrative review. Search strategy: The following databases were examined: PubMed, SciELO and SCOPUS.Criteria for selecting the readings: Articles that have evaluated at least a minimum of 1,000 newborns; specifying the time (hours of life of the newborn) in which the test was accomplished; articles specifying how many days later the retest was performed after the hospital discharge, if the infant failed the test; in the article´s methodology the tests that were used and its stages must be included. The method of choice should be: TEOAEs test and retest in newborns with no risk; TEOAEs in conjunction with ABR and ABR in the retest in newborns with no risk and ABR on the test and retest in newborns with a risk factor; the results should present the pass and fail results of each step, such as the diagnosis result. Results: A total of 3950 references were found in English, Portuguese and Spanish. After removing duplicated studies (300), 3650 references were obtained, that were analyzed through titles and summaries. Of this total, 3500 were excluded for being researches with different topics. Hereby, 15 filled all the inclusion criteria. The final rates of pass and fail found in the studied protocols were the following: for the TEOAEs test/retest protocol the pass rate varied from 99,53% to 97,39% and the fail rate from 2,41% to 0,44%. In the TEOAEs and ABR test protocol and in the ABR retest the pass results ranged from 99,84% to 98% and fail from 0,35% to 0,16%. And in the ABR test/retest protocol in newborns with risk factors the pass rate was reached from 98,62% to 92,74% and the fail rate from 1,7% to 1,38%. All the pass and fail rates are within of what is recommended by literature. Conclusion: The protocol that presented the smaller number of false positives was the TEOAEs combined with the ABR in the test and ABR in retest. The findings indicate that the probability of fail for the TEOAEs in the test and retest is larger than the TEOAEs and ABR in the test and ABR in retest, both for the newborns screened until 24 hours of life and for the newborns screened between 25 and 72 hours of life / A Triagem Auditiva Neonatal Universal (TANU) tem como objetivo realizar o diagnóstico precoce em neonatos. A sua realização utiliza medidas, como as emissões otoacústicas evocadas por estímulo transiente (EOAET) e o potencial evocado auditivo de tronco encefálico (PEATE). Diferentes etapas e protocolos são utilizados na TANU, o que pode alterar os índices de passa e falha de cada programa. Objetivo: Estudar os resultados de índice de passa-falha dos protocolos e etapas utilizados na TANU, realizada com procedimentos eletroacústicos (EOAET) e eletrofisiolóficos (PEATE) por meio de uma revisão integrativa. Método: Tipo de estudo: Revisão integrativa Estratégia de busca: Foram pesquisadas as seguintes bases de dados: PUBMED, SCieLO e SCOPUS. Critério para a seleção dos estudos: artigos que avaliaram um número mínimo de 1000 neonatos; artigos que especificaram as horas de vida do neonato em que foi realizado o teste; artigos que especificaram quantos dias depois da alta hospitalar foi realizado o reteste, caso o neonato falhasse no teste; no método, deveriam constar quais os testes utilizados e suas etapas. Neste caso, os testes utilizados deveriam ser: EOAET no teste e no reteste em neonatos sem risco; EOAET combinado com PEATE no teste e PEATE no reteste em neonatos sem risco e PEATE no teste e no reteste em neonatos com risco; os estudos deveriam apresentar o resultado de passa e falha de cada etapa, assim como o resultado do diagnóstico. Resultados: Foi identificado um total de 3950 referências no idioma inglês, português e espanhol. Após a remoção dos estudos duplicados (300), foram obtidas 3650 referências, que foram analisadas por meio dos títulos e dos resumos. Deste total, 3500 foram excluídos por se tratarem de pesquisas com outro tema. Desta forma, 150 estudos foram selecionados, na íntegra. Deste total, 15 preencheram todos os critérios de inclusão. Os índices de passa e falha final encontrados nos protocolos estudados foi de: para o protocolo EOAET no teste e reteste, o índice de passa variou de 99,53 a 97,39% e falha de 2,41% a 0,44%. No protocolo de EOAET combinado com PEATE no teste, e PEATE no reteste foi de passa em 99,84% a 98%, e falha de 0,35% a 0,16%. No protocolo PEATE no teste e reteste em neonatos com risco o índice de passa foi de 98,62% e 92,74% e falha de 1,7% e 1,38%. Todos os índices de passa e falha estão dentro do que é recomendado pela literatura. Conclusão: O protocolo que apresentou menor número de falso-positivo foi o EOAET combinado com PEATE no teste, e PEATE no reteste. Os resultados mostram que a probabilidade de falha para protocolo- EOAET no teste e reteste é maior do que para o protocolo- EOAET combinado com PEATE no teste, e PEATE no reteste, tanto para o neonatos triados até 24 horas de vida, quanto para o grupo de neonatos triados entre 25 e 72 horas
127

Efeitos da hipóxia tecidual aguda sobre as propriedades eletrofisiológicas dos neurônios pré-simpáticos de ratos previamente submetidos à hipóxia crônica intermitente / Effects of acute tissue hypoxia on electrophysiological properties of the presympathetic neurons from rats submmited to chronic intermitente hypoxia

Amarante, Marlusa Karlen 16 December 2015 (has links)
Nesse estudo investigamos os efeitos da hipóxia tecidual aguda (HA) sobre as propriedades eletrofisiológicas intrínsecas dos neurônios pré-simpáticos bulboespinhais da área rostro-ventrolateral do bulbo (RVLM) de ratos jovens adultos submetidos previamente à hipóxia crônica intermitente (HCI) e os seus respectivos controle. Para marcarmos os neurônios pré-simpáticos bulboespinhais da RVLM, ratos Wistar jovens (P19-P21) anestesiados com ketamina e xilazina, receberam microinjeções bilaterais de rodamina, um traçador fluorescente retrógrado, na coluna intermediolateral da medula espinhal (T3-T6) e 2 dias após a recuperação da cirurgia, os animais foram submetidos ao protocolo de HCI, enquanto que ratos controle foram mantidos em condições de normóxia, durante 10 dias. No décimo primeiro dia, os ratos foram novamente anestesiados para a remoção do cérebro e as fatias do tronco cerebral contendo neurônios pré-simpáticos com marcação positivas foram registrados. Utilizamos a técnica de whole cell patch-clamp para estudo das propriedades eletrofisiológicas desses neurônios. As propriedades eletrofisiológicas intrínsecas foram analisadas antes e após a HA, a qual foi produzida pela perfusão das fatias do tronco cerebral com uma solução hipóxica (95% N2 + 5% CO2) durante 2 minutos na presença de bloqueadores sinápticos excitatórios e inibitórios. Todos os neurônios pré-simpáticos apresentaram característica intrínseca de autodespolarização e a frequência de disparos basal de potenciais de ação (PAs) desses neurônios de ratos do grupo controle e HCI foram similares [Controle= 5,03 ± 0,4 Hz (n=39) vs HCI= 6,31 ± 0,7 Hz (n=31); p > 0,05]. No grupo controle, a HA não alterou a frequência média de disparos de PAs (BS = 5,03 ± 0,4 Hz vs HA = 5,24 ± 0,3 Hz (n=39); p > 0,05], porém revelou diferentes perfis de disparo de PAs após 2 min de exposição à HA: i) 11 neurônios com aumento na frequência de disparos (BS = 5,1 ± 0,7 Hz vs HA = 7 ± 0,7 Hz; p < 0,05]; ii) 21 neurônios sem alteração na frequência de disparos (BS = 4,8 ± 0,5 Hz vs HA = 5,36 ± 0,6 Hz; p > 0,05] e iii) 7 neurônios com diminuição na frequência de disparos (BS = 7,3 ± 1,1 Hz vs HA = 3,6 ± 0,7 Hz; p < 0,05). No grupo HCI, a HA produziu aumento na frequência média de disparos (BS= 6,31 ± 0,7 Hz vs HA= 7,25 ± 0,8 Hz; n=31 - p < 0,05) e na análise do perfil de disparo de PAs, a HA revelou 2 subpopulações: i) 9 neurônios com aumento na frequência de disparos (BS = 4,7 ± 0,8 Hz vs HA = 8,2 ± 1,4 Hz; p < 0,05) e ii) 22 neurônios sem alteração na frequência de disparos (BS = 7,0 ± 1,0 Hz vs HA = 6,8 ± 1,0 Hz; p > 0,05). Esse estudo nos permitiu revelar diferentes subpopulações de neurônios pré-simpáticos que responderam de forma distintas à HA. Os resultados também sugerem que a HCI teria um efeito pré- condicionante na excitabilidade intrínseca dos neurônios pré-simpáticos em resposta à HA / In this study we evaluated the effects of acute hypoxia (AH) on the intrinsic electrophysiological properties of presympathetic neurons from rostro ventrolateral medulla (RVLM) of juvenile rats exposed to chronic intermittent hypoxia (CIH) or normoxic condition (control group). To label the RVLM bulbospinal presympathetic neurons, young Wistar rats (P 19 - 21) anesthetized with ketamine and xylazine, received bilateral microinjections of a fluorescent retrograde tracer (rhodamine retrobeads) were performed into the intermediolateral column of spinal cord (T3-T6) and two days after recovery of the surgery, the animals were submitted to CIH or normoxic protocol, during 10 days. On the 11th day, under anesthesia, brainstem slices were obtained and only the labeled RVLM presympathetic neurons were recorded, using whole-cell patch-clamp approach to study the electrophysiological properties of these neurons. The intrinsic electrophysiological properties were analyzed before and after AH, which was produced by slice perfusion with hypoxic solution (95% N2 and 5% CO2) during 2 min in the presence of excitatory and inhibitory synaptic antagonists. All recorded RVLM presympathetic neurons presented intrinsic pacemaker activity and the baseline firing frequency of these neurons from control and CIH group were similar [Control= 5,03 ± 0,4 Hz (n=39) vs HCI= 6,31 ± 0,7 Hz (n=31); p > 0,05]. In the control group, AH do not change the firing rate (BS = 5,03 ± 0,4 Hz vs HA = 5,24 ± 0,3 Hz (n=39); p > 0,05), but revealed different pattern of firing frequency after 2 min of AH: i) 11 neurons increased the firing frequency (BS = 4,9 ± 0,9 Hz vs HA = 6,9 ± 1,0 Hz; p < 0,05) ; ii) 21 neurons do not change the firing frequency (BS = 4,8 ± 0,5 Hz vs HA = 5,36 ± 0,6 Hz; p > 0,05) and iii) 7 neurons decreased the firing frequency (BS = 7,3 ± 1,1 Hz vs HA = 3,6 ± 0,7 Hz; p < 0,05). In the CIH group, the AH increased the firing rate comparing with basal condition (SB= 6,31 ± 0,7 Hz vs AH= 7,25 ± 0,8 Hz; n=31 - p < 0,05) and analyzing the pattern of action potential, AH revealed 2 subpopulations in this group: i) 9 neurons increased the firing frequency (SB = 4,7 ± 0,8 Hz vs AH = 8,2 ± 1,4 Hz; p < 0,05) and ii) 22 neurons do not change the firing frequency (SB = 7,0 ± 1,0 Hz vs AH = 6,8 ± 1,0 Hz; p > 0,05).. The data shows that AH revealed different subpopulations of presympathetic neurons and suggest that CIH plays a preconditioning in the intrinsic excitability of presympathetic neurons in response to acute hypoxia
128

Comparison of Abr Recordings from Tympanic-Membrane and Ear-Canal Electrode

Murnane, Owen D., Parent, T. 01 January 1995 (has links)
No description available.
129

The Round Window Membrane - Gateway to the Cochlea : A Morphological and Electrophysiological study

Nordang, Leif January 2002 (has links)
<p>Topical treatment of several inner ear diseases through the round window membrane (RWM) might be feasible in the near future. Bacteria toxins, ototoxic drugs and noise trauma seem to harm the inner ear by a common pathway which involves, excessive outflow of the afferent neurotransmitter glutamate and formation of nitric oxide (NO), which can severely damage cells/nerve endings and lead to cell death.</p><p>In this study we used 98 Sprague-Dawley rats and seven human temporal bones. Various substances were instilled into the middle ear of the rat, such as Pseudomonas Aeruginosa Exotoxin (PaExoA), gentamicin, NO-inhibitor N-Omega-Nitro-L-Arginine Methyl Ester (L-NAME), and glucocorticoids. The effects of the substances were studied by morphological analysis of RWM and the endolymphatic sac (ES) by light and electron microscopic. Hearing level was measured in the rats by ABR technique. The human temporal bones were studied immunomorphologically to search for glutamate.</p><p>In the human inner ear, glutamate receptors and glutamine synthetase, were identified. In the rat, we found, following PaExoA exposure, reversible and permanent hearing loss and morphological changes in the RWM. The ES showed increased numbers of macrophages and thickening of the epithelia. When L-NAME was used as an otoprotector from gentamicin ototoxicity a therapeutic effect in the high frequency area was found. Hydrocortisone (but not dexamethasone) exposure of the RWM resulted in membrane thickening, and adjacent to the membrane, inflammatory cells.</p><p>The importance of the RWM as a portal for toxic substances and topical treatment of inner ear diseases was highlighted in this study. The difficulties of applying drugs in the round window niche were exposed. The results of this study add important knowledge concerning certain mechanisms of inner ear injury and help us to understand possibilities and problems of local treatment of inner ear diseases in patients.</p>
130

The Round Window Membrane - Gateway to the Cochlea : A Morphological and Electrophysiological study

Nordang, Leif January 2002 (has links)
Topical treatment of several inner ear diseases through the round window membrane (RWM) might be feasible in the near future. Bacteria toxins, ototoxic drugs and noise trauma seem to harm the inner ear by a common pathway which involves, excessive outflow of the afferent neurotransmitter glutamate and formation of nitric oxide (NO), which can severely damage cells/nerve endings and lead to cell death. In this study we used 98 Sprague-Dawley rats and seven human temporal bones. Various substances were instilled into the middle ear of the rat, such as Pseudomonas Aeruginosa Exotoxin (PaExoA), gentamicin, NO-inhibitor N-Omega-Nitro-L-Arginine Methyl Ester (L-NAME), and glucocorticoids. The effects of the substances were studied by morphological analysis of RWM and the endolymphatic sac (ES) by light and electron microscopic. Hearing level was measured in the rats by ABR technique. The human temporal bones were studied immunomorphologically to search for glutamate. In the human inner ear, glutamate receptors and glutamine synthetase, were identified. In the rat, we found, following PaExoA exposure, reversible and permanent hearing loss and morphological changes in the RWM. The ES showed increased numbers of macrophages and thickening of the epithelia. When L-NAME was used as an otoprotector from gentamicin ototoxicity a therapeutic effect in the high frequency area was found. Hydrocortisone (but not dexamethasone) exposure of the RWM resulted in membrane thickening, and adjacent to the membrane, inflammatory cells. The importance of the RWM as a portal for toxic substances and topical treatment of inner ear diseases was highlighted in this study. The difficulties of applying drugs in the round window niche were exposed. The results of this study add important knowledge concerning certain mechanisms of inner ear injury and help us to understand possibilities and problems of local treatment of inner ear diseases in patients.

Page generated in 0.0764 seconds