• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 23
  • 7
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 140
  • 78
  • 46
  • 39
  • 37
  • 36
  • 30
  • 30
  • 27
  • 17
  • 16
  • 16
  • 16
  • 16
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

A Comparison of Cyclic Valgus Loading on Reconstructed Ulnar Collateral Ligament of the Elbow

Shah, Roshan Pradip 09 April 2008 (has links)
This study compares the biomechanics of early cyclic valgus loading of the ulnar collateral ligament (UCL) of the elbow repaired by either the Jobe technique or the docking technique. Better understanding of the biomechanical properties of each reconstruction may help surgeons choose the optimal surgical technique, particularly in planning earlier rehabilitation programs. Sixteen fresh frozen cadaver limbs (eight pairs) were randomized to either the Jobe cohort or the docking cohort. First intact UCLs were tested, followed by the repaired constructions. A Bionix MTS apparatus applied a constant valgus load to the elbows at 70o flexion, and valgus displacement was measured and then used to calculate valgus angle displacement. The docking group had significantly less valgus angle displacement than the Jobe group at cycles 100 and 1,000 (p = 0.0189 and 0.0076, respectively). Four of the eight specimens in the Jobe group failed at the tendon-suture interface before reaching 1,000 cycles, at cycles 7, 24, 250, and 362. None of the docking specimens failed before reaching 1,000 cycles. In this cadaveric study, the docking technique resulted in less angulation of the elbow in response to cyclic valgus loading as compared to the Jobe technique. The better response to valgus loading of the docking reconstruction may translate into a better response to early rehabilitation. Further study is needed to determine if this difference translates into improved clinical outcomes.
32

An analysis of the differences in preemptive kidney transplantation between blacks and whites

Brown, Kennard D., January 2008 (has links) (PDF)
Thesis (Ph.D. )--University of Tennessee Health Science Center, 2008. / Title from title page screen (viewed on April 24, 2008 ). Research advisor: Shelly White-Means, Ph.D. Document formatted into pages (xi, 101 p. : ill.). Vita. Abstract. Includes bibliographical references (p. 94-100).
33

Anticorpos antidoador em baixos níveis detectados por meio de prova cruzada por citometria de fluxo pré-transplante : influência na sobrevida do enxerto em transplante de rim de cadáver

Silva, Luiz Alberto Michet da January 2004 (has links)
Resumo não disponível.
34

Anticorpos antidoador em baixos níveis detectados por meio de prova cruzada por citometria de fluxo pré-transplante : influência na sobrevida do enxerto em transplante de rim de cadáver

Silva, Luiz Alberto Michet da January 2004 (has links)
Resumo não disponível.
35

Os sulcos e giros na face súpero-lateral do lobo occipital / The occipital lobe convexity sulci and gyri

Raphael Vicente Alves 28 April 2014 (has links)
INTRODUÇÃO: A anatomia da face súpero-lateral do lobo occipital é tão complexa e variável que a sua descrição precisa não é encontrada nos livros clássicos de anatomia. Os sulcos e giros occipitais da convexidade cerebral encontram-se descritos com nomenclaturas diferentes de acordo com os diversos autores. O objetivo deste estudo foi investigar e descrever a anatomia da face súpero-lateral lobo occipital e esclarecer a sua nomenclatura. MÉTODOS: As configurações anatômicas dos sulcos e giros na face súpero-lateral do lobo occipital de 20 hemisférios cerebrais foram examinados a fim de identificar os padrões mais característicos e consistentes. RESULTADOS: Os sulcos occipitais mais característicos e consistentes identificados neste estudo foram o sulco intraoccipital, o sulco occipital transverso e o sulco occipital lateral. A morfologia da junção do sulco occipital transverso com o sulco intraoccipital foi identificada como sendo o aspecto mais importante para definir o padrão de giros cerebrais da face súperolateral do lobo occipital. CONCLUSÕES: O conhecimento das principais características dos sulcos e giros occipitais permite o reconhecimento de uma configuração básica do lobo occipital e a identificação de suas principais variações anatômicas / BACKGROUND: The anatomy of the occipital lobe convexity is so intricate and variable that its precise description is not found in the classic anatomy textbooks, and the occipital sulci and gyri are described with different nomenclatures according to different authors. The aim of this study was to investigate and describe the anatomy of the occipital lobe convexity and clarify its nomenclature. METHODS: The configurations of sulci and gyri on the lateral surface of the occipital lobe of 20 cerebral hemispheres were examined in order to identify the most characteristic and consistent patterns. RESULTS: The most characteristic and consistent occipital sulci identified in this study were the intraoccipital, transverse occipital, and lateral occipital sulci. The morphology of the transverse occipital sulcus and the intraoccipital sulcus connection was identified as the most important aspect to define the gyral pattern of the occipital lobe convexity. CONCLUSIONS: Knowledge of the main features of the occipital sulci and gyri permits the recognition of a basic configuration of the occipital lobe and the identification of its sulcal and gyral variations
36

Anticorpos antidoador em baixos níveis detectados por meio de prova cruzada por citometria de fluxo pré-transplante : influência na sobrevida do enxerto em transplante de rim de cadáver

Silva, Luiz Alberto Michet da January 2004 (has links)
Resumo não disponível.
37

Efeito da descompressão limitada do nervo fibular após a osteotomia em varo da tíbia proximal: estudo em cadáveres / The effect of limited peroneal nerve decompression after varus osteotomy of the proximal tibia - a cadaver study

Monica Paschoal Nogueira 23 January 2004 (has links)
As lesões nervosas são freqüentes nos alongamentos e correções de deformidades dos membros inferiores. As lesões por estiramento do nervo fibular podem ser tratadas pela redução da taxa de alongamento ou do ritmo de correção gradual de deformidades até melhora clínica, ou pela descompressão cirúrgica, como demonstrado em estudos clínicos. Essa cirurgia mostrou-se eficaz para o tratamento dessas lesões, assim como outras de diversas etiologias, mas a quantificação da redução da tensão no nervo, a partir de uma descompressão limitada, não é conhecida. O presente estudo objetivou a mensuração da variação da tensão no nervo fibular após a osteotomia em varo da tíbia proximal, e em seguida após a descompressão limitada desse nervo. Essa descompressão limitada é realizada em dois pontos considerados anatomicamente importantes para o aumento da tensão no nervo: as fáscias superficial e profunda do músculo fibular longo, e o septo intermuscular anterior. A tensão no nervo foi medida através de um aparelho desenvolvido para tracionar o nervo perpendicularmente a seu eixo e medir sua reação em microdeformações com um transdutor de força. O gráfico de força por deformação produzido pelo computador mostrou uma fase inicial de acomodação, e depois apresentou comportamento linear. Essa porção da linear da curva, possibilitou o cálculo da rigidez do nervo em três momentos: pré osteotomia em varo, após a osteotomia em varo, e após a descompressão do nervo fibular. Os valores obtidos em sete cadáveres (quatorze membros inferiores) foram tratados estatisticamente através de análise de variância para medidas repetidas, obtendo-se o aumento significativo da tensão (p = 0,0002) após a osteotomia e a redução da mesma (p = 0,0003) após a descompressão do nervo fibular ao nível do colo da fíbula. Foi observado também que não houve diferença significativa entre os valores observados ao início em relação aos valores obtidos após descompressão do nervo (p= 0,3666). / Nerve injuries are complications often observed in lengthening and deformity correction in lower limbs. The peroneal nerve stretch lesions can be treated by slowing the rate of distraction or deformity correction or by surgical decompression, as demonstrated by clinical studies. This surgery proved to be very efficient to treat these lesions, but the amount of reduction of the nerve tension was not quantified. This study aims to measure the variation of the tension in the peroneal nerve (after varus osteotomy in the proximal tibia and after surgical decompression). The decompression is performed in two levels considered anatomically important to the increase of the nerve tension: the superficial and deep peroneus longus muscle fasciae, and the anterior intramuscular septum. The nerve tension was measured through a device developed to apply traction in the nerve perpendiculary to its axis, and capture the nerve reaction with a force transducer. It was then possible to plot a graphic of force by deformation that showed an accomodation phase followed by a linear segment. This region of the curve allowed to obtain the rigidity values in the three situations: pre varus osteotomy, after varus osteotomy and after peroneal nerve decompression. The values obtained in seven cadavera (fourteen lower limbs) were statistically treated by the multiple variance analysis. The results showed there was a significative increase of tension (p = 0.0002) after the osteotomy and varus positioning, and an also significant decrease (p = 0.0003) after peroneal nerve decompression at the level of the fibular neck. It was also observed no significative difference between the values obtained in the beginning of the experiment (pre varus osteotomy) if compared with the values obtained after nerve decompression (p= 0.3666).
38

Estudo anatômico das dimensões e do padrão vascular do retalho lateral do braço ampliado distalmente ao epicôndilo lateral / Anatomic study of the dimensions and the vascular pattern of distal part to lateral epicondyle of the extended lateral arm flap

Renato Ribeiro Gonçalves 28 April 2003 (has links)
Foram realizadas dissecções anatômicas de 45 membros superiores de cadáveres, com o objetivo de avaliar as dimensões e o padrão vascular da porção distal ao epicôndilo lateral do retalho lateral do braço. Todos os casos deste estudo eram do sexo masculino, com idade superior a 21 anos. Os casos foram divididos em grupos A, B, e C e submetidos a injeção de contraste diretamente na artéria colateral radial posterior. Nos cadáveres do Grupo A, foi injetado contraste a base de azul de metileno e serviu para avaliar o maior comprimento e largura de pele corada pelo contraste, tendo como local para início das medidas o epicôndilo lateral do úmero. No Grupo B foi utilizada a mesma metodologia do Grupo A, sendo acrescentado para cada cadáver em estudo, uma ficha com os dados antropométricos e serviu para avaliar a extensão de pele corada pelo contraste e correlacioná-la com os dados antropométricos individuais. Nos cadáveres do Grupo C foi utilizado contraste a base de látex e serviu para avaliar o padrão vascular da artéria colateral radial posterior encontrado distalmente ao epicôndilo lateral. Em todos os casos a pele foi corada pelo contraste distalmente ao epicôndilo lateral, com o comprimento variando de 4 cm a 12 cm, com média de 7,5 cm e a largura variando de 3 cm a 10 cm, com média de 6 cm. Houve em todas as dissecções um padrão plexiforme da artéria colateral radial posterior distalmente ao epicôndilo lateral. Ocorreu uma correlação entre os comprimentos do braço e do antebraço e as dimensões da área corada pelo contraste, distalmente ao epicôndilo lateral. O autor conclui que é possível a confecção do retalho lateral do braço na forma ampliada, incluindo a pele da região proximal do antebraço, sendo os limites de 7,5 cm de comprimento por 6 cm de largura, distalmente ao epicôndilo lateral, limites seguros para a confecção deste tipo de retalho. A artéria colateral radial posterior apresenta um padrão arterial plexiforme, distalmente ao epicôndilo lateral do úmero. Existe uma relação direta entre o comprimento do retalho lateral do braço ampliado distalmente ao epicôndilo lateral e os comprimentos do braço e do antebraço / Anatomical dissections of forty-five upper limbs of cadavers were made in order to evaluate the dimensions and the vascular pattern of distal part to lateral epicondyle of lateral arm flap. All cases of this study were male, with more than twenty-one years old. The cases were divided into groups A, B and C and they were submitted to a contrast injection directly on posterior radial collateral artery. Into cadavers of Group A it was injected contrast a basis of methylene blue to evaluate the longest length and width of coloured skin by contrast. The place for beginning of measures was the lateral epicondyle of humerus. In the group B, it was used the same methodology of group A, and a record card with anthropometric data of each cadaver. With them it was possible to evaluate the extension of coloured skin by contrast and correlate it with individual anthropometric data. In the cadavers of group C was used contrast a basis of latex in order to evaluate the vascular pattern of posterior radial collateral artery which was found distally to lateral epicondyle. In all cases the skin was coloured by contrast distally to lateral epicondyle, with the length changing from 4 cm to 12 cm, mean length was 7,5 cm and the width changing from 3 cm to 10 cm, mean width was 6 cm. In all dissections, there was a plexiform pattern of posterior radial collateral artery distally to lateral epicondyle. There was a correlation between the length of forearm and the dimensions of coloured area by contrast distally to lateral epicondyle. The author concluded that it is possible the confection of lateral arm flap in enlarged way, including the skin of proximal region of forearm, distally to lateral epicondyle, with distal limits 7,5 cm of length to 6 cm of width to lateral epicondyle, secure limits for confection of this flap. The posterior radial collateral artery presents a plexiform arterial pattern, distally to lateral epicondyle. There is a direct relation between the length of lateral arm flap enlarged distally to lateral epicondyle and the legths of arm and forearm
39

Importância dos diferentes estabilizadores estáticos póstero-laterais do joelho: estudo biomecânico / The role of the different static stabilizers of the posterolateral corner of the knee: a biomechanical study

Rodrigo Campos Pace Lasmar 09 May 2006 (has links)
O objetivo deste trabalho foi avaliar a importância relativa dos diferentes estabilizadores estáticos do canto póstero-lateral do joelho. Para isso foram utilizados 10 joelhos de cadáveres que foram submetidos a testes biomecânicos com a aplicação de forças para a deformação em varo e em rotação externa. Os joelhos foram testados em quatro situações diferentes e sempre na mesma seqüência: com a articulação íntegra, após a secção do ligamento colateral lateral, após a secção do ligamento colateral lateral e do complexo poplíteo-fibular (tendão do poplíteo + ligamento poplíteo-fibular) e após a secção do ligamento colateral lateral, do complexo poplíteo-fibular e da cápsula póstero-lateral. Os testes foram feitos com os joelhos em extensão, em 30 e em 60 graus de flexão. Os parâmetros estudados foram a deformação angular e a rigidez durante a aplicação do momento de flexão (varo) de 15 N.m e do momento de torção (rotação externa) de 6 N.m. A análise estatística foi realizada com o teste de comparações múltiplas de Tukey. Através da análise dos resultados obtidos com os testes biomecânicos e comparando os valores obtidos nas quatro situações estudadas entre si, foi possível interpretar a função específica de cada estrutura do canto póstero-lateral do joelho, em cada ângulo de flexão testado. Neste estudo, o ligamento colateral lateral foi importante na estabilização do joelho para o varo em extensão, em 30 e em 60 graus de flexão. O complexo poplíteo-fibular foi a estrutura mais importante na estabilização do joelho para a rotação externa, dentre as estruturas avaliadas, atuando em todos os ângulos de flexão testados. Além disto, complexo poplíteo-fibular foi importante na estabilização para o varo quando o joelho se encontrava em 30 e em 60 graus de flexão. Já a cápsula póstero-lateral foi importante na estabilização para o varo e para a rotação externa quando o joelho se encontrava em extensão, perdendo sua função à medida que o joelho foi flexionado. Em 30 graus de flexão, a cápsula póstero-lateral foi importante apenas para a estabilização em varo do joelho. / The purpose of this study was to evaluate, in cadaver knees, the relative importance of the different static stabilizers of the posterolateral corner of the knee. Tests were performed with the application of a varus and external rotation force to the knee in extension, 30 and 60 degrees of flexion, using 10 cadaver knees. The forces were applied initially to an intact knee and then repeated after a selective sectioning of the ligaments: section of the lateral collateral ligament; section of the lateral collateral ligament and the popliteofibular complex; and section of the lateral collateral ligament, the popliteofibular complex and the posterolateral capsule. The parameters studied were the angular deformity and rigidity while the knees were being submitted to a 15 newton-meter varus torque and a 6 newton-meter external tibial torque. Statistical analysis was performed using the ANOVA and Tukey tests. Our findings showed that the lateral collateral ligament was important in varus stability at 0, 30 and 60 degrees; the popliteus-fibular complex was the most important structure in external rotation stability at all angles of flexion and was also important for varus stability at 30 and 60 degrees; the posterolateral capsule was important for varus stability at 0 and 30 degrees, and for external rotation stability in extension.
40

Estudo dos reparos anatômicos para o acesso intra-hepático aos pedículos glissonianos durante ressecções hepáticas / Study of the anatomy of liver landmarks for the intrahepatic approach to glissonian pedicles during hepatectomies

Rodrigo Cañada Trofo Surjan 24 September 2014 (has links)
Ressecções hepáticas regradas baseiam-se em alguns princípios técnicos básicos, como controle vascular, delineamento isquêmico das áreas a serem ressecadas e preservação máxima de parênquima. Eles são alcançados através do acesso intrahepático aos pedículos glissonianos, que se baseia na abordagem dos segmentos hepáticos através do acesso aos pedículos dentro do fígado. Com pequenas incisões sobre pontos de reparo anatômicos bem definidos são acessados pedículos correspondentes aos segmentos a serem ressecados, tornando desnecessárias dissecções extensas do parênquima hepático.Neste estudo, parâmetros anatômicos relacionados à técnica de acesso intra-hepático aos pedículos glissonianos foram estudados em cadáveres com o fígado in loco. Ele propiciou a determinação precisa de pontos de reparo confiáveis e simples a serem utilizados durante estes procedimentos.Foram estudados 37 fígados provenientes de cadáveres adultos. Vinte e cinco cadáveres eram do sexo masculino e doze do sexo feminino. Foram excluídos cadáveres que tivessem qualquer fator que alterasse a anatomia original do andar superior do abdome e fígados com aspecto cirrótico. As aferições realizadas foram realizadas com instrumentos de precisão. Os dados obtidos foram expressos em média ± desvio padrão. Os indivíduos foram então divididos em grupos de acordo com gênero e peso do fígado e os grupos foram comparados estatisticamente através do teste t de Student. Setenta por cento dos cadáveres apresentavam veia hepática direita acessória, sendo este achado muito superior ao encontrado na literatura. O diâmetro médio deste vaso, quando presente, foi de 6,8 mm. As veias hepáticas média e esquerda apresentavam tronco comum em direção à veia cava em 51% dos casos, valor menor do que o habitualmente encontrado na literatura.Em 70% dos fígados a fissura de Gans encontrava-se aberta. Nestes, 80% continha o pedículo do segmento 6. A ponte entre os segmentos 3 e 4 encontrava-se aberta em 41% dos casos.O diâmetro médio do pedículo esquerdo foi de 28,2 mm, enquanto o do direito foi de 26,8 mm.A distância média entre a bifurcação do tronco portal e a inserção caudal do ligamento de Arantius foi de 32,9 mm. Esta distância é importante na realização do acesso intra-hepático a pedículos esquerdos. A distância média entre a bifurcação do tronco portal principal e a do pedículo direito foi de 26,2 mm. Este valor deve ser levado em consideração no acesso aos pedículos do fígado direito.A distância máxima observada entre a placa hilar e a bifurcação do tronco portal representa quanto se deve aprofundar na placa hilar para acesso dos pedículos direito e esquerdo e foi de 7 mm.Não foi observada diferença estatisticamente significativa em praticamente todos os parâmetros avaliados quando comparados os grupos divididos de acordo com gênero e peso do fígado. Isso demonstra a consistência dos parâmetros relacionados à realização do acesso intra-hepático aos pedículos glissonianos, garantindo reprodutibilidade ao método.Os resultados obtidos tornaram possíveis grandes avanços técnicos na realização de hepatectomias abertas ou laparoscópicas com acesso intra-hepático aos pedículos glissonianos, e resultaram em uma série de dados anatômicos que podem guiar cirurgiões de modo a evitar acidentes e tornar mais fácil sua execução / Anatomical liver resections are based on some basic technical principles such as vascular control, ischemic delineation of areas to be resected and maximum parenchymal preservation. Those are achieved by the intrahepatic glissonian approach, which consists in accessing the pedicles of hepatic segments to be resected within the hepatic parenchyma. Small incisions on well-defined anatomical landmarks are performed to approach the desired pedicles, making extensive dissection of the liver parenchyma unnecessary.In this study, anatomical parameters related to the intrahepatic glissonian approach to hepatic pedicles were studied in cadavers with the liver in loco. It allowed the accurate determination of anatomical landmarks that are reliable and easy to be used.Thirty-seven livers from adult cadavers were studied. Twenty-five cadavers were male and twelve female. Corpses that had any factor that altered the original anatomy of the upper abdomen and cirrhotic livers were excluded. The measurementswere performed with precision instruments. Data were expressed as mean ± standard deviation. The subjects were divided into groups according to gender and liver weight and the groups were compared statistically by the Student t test.Seventy percent of the cadavers presented an accessory right hepatic vein, much more frequent than previously reported in the literature. The average diameter of the vesselwas 6.8 mm. The middle and left hepatic veins presented a common trunk in 51% of cases, lower than typically found in the literature.In 70% of livers there was a patent incisura dextra of Gans. When present, 80% contained the pedicle of segment 6. There was an open hepatic bridge between segments 3 and 4 in 41% of cases.The mean diameter of the left pedicle was 28.2 mm, while the mean diameter of the right pedicle was 26.8 mm.The mean distance between the bifurcation of the main portal trunk and the caudal insertion of Arantius ligament was 32.9 mm. This distance is important in achieving the intrahepatic access to left pedicles. The mean distance between the bifurcation of the main portal trunk and the right pedicle was 26.2 mm. This value should be taken into consideration when approaching pedicles of the right liver.The maximum distance between the hilar plate and the bifurcation of the main portal trunk was 7 mm. It represents how deep one should enter the hepatic parenchyma through the hilar plate in order to approach the right and left pedicles.No statistically significant difference was observed in virtually all parameters when groups divided according to gender and liver weight were compared. This demonstrates the consistency of the anatomical parameters related to the intrahepatic glissonian approach, ensuring reproducibility to the method. Theresults obtained in this study made possible major technical advances in the realization of open and laparoscopic hepatectomies with intrahepatic glissonian approach to hepatic pedicles, and resulted in a series of anatomical data that can guide surgeons to prevent accidents and make it easier to accomplish safe and effective procedures

Page generated in 0.6107 seconds