• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • Tagged with
  • 33
  • 33
  • 33
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de um novo protocolo para remoção de retentores metálicos por meio do ultrassom em dentes multirradiculares

Souza, Samir Noronha de 24 February 2014 (has links)
Submitted by Geyciane Santos (geyciane_thamires@hotmail.com) on 2015-06-16T15:47:05Z No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T18:26:30Z (GMT) No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T18:27:24Z (GMT) No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) / Made available in DSpace on 2015-06-16T18:27:24Z (GMT). No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) Previous issue date: 2014-02-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this paper is to evaluate in vitro a new protocol for intra-radicular posts removal for multi-radicular teeth by applying ultrasonic vibration. Forty lower molars were endodontically treated in order to receive cast posts and cores, being distributed in 4 groups: GI – control without slot; GII – control with slot; GIII – ultrasound application in core without slot; GIV – ultrasound application in core with slot. After the cast posts fixation using zinc phosphate cement, the ultrasonic vibration was applied in group III for 1 minute, dividing 15 seconds on each surface and in group IV 15 seconds on facial and lingual surface, and 30 seconds inside the slot totaling 1 minute. Thereafter, samples were subjected to tensile test in Universal Assay Machine at the speed of 1mm/min. The maximum tensile strength needed for intra-radicular posts removal was registered in Newton and its data were subjected to statistical analysis ANOVA e Tukey-Kramer. The results presented statistically significant differences between the tested groups (GI – 234,34 N; GII – 201,67 N; GIII – 139,57 N; GIV – 83,23 N), with the smallest average of the tensile strength obtained when ultrasonic vibration on the core slotted applied (p<0,05). It is concluded that the implemantation of a slot in the core and ultrasonic application on all the surfaces and inside the slot caused a reduction of force required for removing cast posts and cores fixed with zinc phosphate in multi-radicular teeth. / Este trabalho visa avaliar in vitro um novo protocolo para remoção de retentores intrarradiculares em dentes multirradiculares aplicando a vibração ultrassônica. Quarenta molares inferiores foram tratados endodonticamente para receber retentores intrarradiculares fundidos, sendo distribuídos em 4 grupos: GI – controle sem fenda; GII – controle com fenda; GIII – aplicação ultrassom em núcleo sem fenda; GIV – aplicação de ultrassom em núcleo com fenda. Após a fixação dos retentores com cimento de fosfato de zinco, a vibração ultrassônica foi realizada no grupo III durante 1 minuto, sendo 15 segundos em cada face e no grupo IV 15 segundos nas faces vestibular e lingual, e 30 segundos dentro da fenda, totalizando 1 minuto. Em seguida, os corpos-de-prova foram submetidos ao teste de tração na Máquina Universal de Ensaio com velocidade de 1 mm/min. A força de tração máxima necessária para a remoção do retentor intrarradicular foi registrada em Newton e os dados foram submetidos à análise estatística ANOVA e Tukey-Kramer. Os resultados mostraram haver diferença estatística significante entre os grupos testados (GI – 234,34 N; GII – 201,67 N; GIII – 139,57 N; GIV – 83,23 N), sendo a menor média da força de tração obtida quando se aplicou vibração ultrassônica sobre o núcleo com fenda (p<0,05). Conclui-se que a realização de uma fenda no núcleo e a aplicação ultrassônica em todas as faces e dentro da fenda promoveu a redução da força necessária para a remoção de retentores intrarradiculares metálicos fixados com fosfato de zinco em dentes multirradiculares.
12

Indicadores sociais contextuais e individuais associados ao edentulismo em idosos brasileiros: análise multinível

Gomes, José Felipe de Freitas 28 August 2014 (has links)
Submitted by Geyciane Santos (geyciane_thamires@hotmail.com) on 2015-06-16T15:20:28Z No. of bitstreams: 1 Dissertação - José felipe de Freitas Gomes.pdf: 1288785 bytes, checksum: e279518c5c0d5e8a10ec57f74309e2c5 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T18:32:38Z (GMT) No. of bitstreams: 1 Dissertação - José felipe de Freitas Gomes.pdf: 1288785 bytes, checksum: e279518c5c0d5e8a10ec57f74309e2c5 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T18:34:37Z (GMT) No. of bitstreams: 1 Dissertação - José felipe de Freitas Gomes.pdf: 1288785 bytes, checksum: e279518c5c0d5e8a10ec57f74309e2c5 (MD5) / Made available in DSpace on 2015-06-16T18:34:37Z (GMT). No. of bitstreams: 1 Dissertação - José felipe de Freitas Gomes.pdf: 1288785 bytes, checksum: e279518c5c0d5e8a10ec57f74309e2c5 (MD5) Previous issue date: 2014-08-28 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / Despite the reduction in tooth loss worldwide, edentulism is still considered important problem among the elderly. Added to this, the contextual social determinants associated with tooth loss are poorly understood. The aim of this study was to estimate the prevalence and geographical distribution of edentulism in the elderly population residing in state capitals and the Federal District, as well as to test the association of contextual and individual socioeconomic inequalities with edentulism. We used data of the elderly 65 to 74 years who participated in the National Oral Health Survey (SB Brazil 2010) and had completely filled for the investigated variables (n = 5435). Contextual social indicators included Municipal Human Development Index (HDI-M) and the Gini Index. Other contextual variables were assessed as coverage of oral health care by the Family Health Strategy (ESB / ESF) and the water fluoridation. The individual variables included gender, ethnicity, family income, years of education, number of residents per room and number of household assets. Multilevel logistic regression models were used to estimate odds ratios (OR) and 95% intervals of confidence (95% CI) between contextual and individual variables and edentulism. The prevalence of edentulism in the Brazilian elderly was 68.6% (95% CI 64.9, 72.2), with considerable variation between state capitals and the Federal District. The interaction variable (HDI-M and family income) was, in all its categories, independently associated with edentulism. Among the individual variables, it was found that males (OR 0.60, 95% CI 0.52 to 0.66) and with black skin color (OR 0.78, 95% CI 0.63 to 0.96 ) had lower chances for edentulism, while individuals with lower education (OR 4.46, 95% CI 3.61 to 5.52) and fewer household assets (OR 1.30, 95% CI 1.10 to 1 , 54) showed greater risk for tooth loss. The results suggest that the level of contextual economic development as well as individual characteristics of social position are associated with the prevalence of edentulism. / Apesar da redução da perda dentária em todo o mundo, o edentulismo ainda é considerado importante problema entre os idosos. Somado a isso, os determinantes sociais contextuais associados ao edentulismo são pouco conhecidos. Este estudo teve por objetivo estimar a prevalência e a distribuição geográfica do edentulismo na população idosa domiciliada nas capitais brasileiras e Distrito Federal, assim como testar a associação das desigualdades socioeconômicas contextuais e individuais com o edentulismo. Para isso, foram utilizados dados dos idosos de 65 a 74 anos que participaram da Pesquisa Nacional de Saúde Bucal – SB Brasil 2010 e que possuíam os dados completamente preenchidos para as variáveis investigadas (n=5435). Os indicadores sociais contextuais incluíram o Índice de Desenvolvimento Humano Municial (IDH-M) e o Índice de Gini. Outras variáveis contextuais avaliadas foram à cobertura de equipes de saúde bucal da Estratégia Saúde da Família (ESB/ESF) e a fluoretação da água de abastecimento. As variáveis individuais incluíram sexo, cor da pele, renda familiar, anos de estudos, número de moradores por cômodo e número de bens no domicílio. Modelos de regressão logística multinível foram usados para estimar odds ratios (OR) e intervalos de 95% de confiança (IC 95%) entre as variáveis contextuais e individuais e o edentulismo. A prevalência de edentulismo em idosos brasileiros foi de 68,6% (IC95% 64,9-72,2), com variações consideráveis entre as capitais brasileiras e o Distrito Federal. A variável de interação (IDH-M e renda familiar) foi, em todas as suas categorias, independentemente associada ao edentulismo. Dentre as variáveis individuais, verificou-se que indivíduos do sexo masculino (OR 0,60; IC95% 0,52-0,66) e com cor de pele preta ( OR 0,78; IC95% 0,63-0,96) apresentaram menores chances para o edentulismo, enquanto indivíduos com menor escolaridade (OR 4,46; IC95% 3,61-5,52) e com menor número de bens no domicílio (OR 1,30; IC95% 1,10-1,54) apresentaram maiores chances para perda dentária. Os resultados obtidos sugerem que o nível de desenvolvimento econômico contextual, bem como características individuais de posição social estão associados à prevalência de edentulismo.
13

Efeito de diferentes concentrações de ascorbato de sódio na resistência de união ao esmalte clareado

Silva, Cristiano Pires e 06 February 2015 (has links)
Submitted by Kamila Costa (kamilavasconceloscosta@gmail.com) on 2015-06-24T20:51:58Z No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-08T18:16:12Z (GMT) No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-08T18:19:19Z (GMT) No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) / Made available in DSpace on 2015-07-08T18:19:19Z (GMT). No. of bitstreams: 1 Dissertação-Cristiano P e Silva.pdf: 2768387 bytes, checksum: 2918349c69f33356b77eef93c4a83a6b (MD5) Previous issue date: 2015-02-06 / Não Informada / After completing the tooth bleaching, reaction products remain in the tooth structure not allowing the correct polymerization of adesives restorations. The purpose of this study was to investigate the antioxidants effects of sodium ascorbate hydrogel on the residual oxygen in the bovine enamel structure bleached with hydrogen peroxide and after restorated with composite resin. One hundred and twenty bovines teeth were divided into twelve groups (n: 10), the groups G1;G2;G3;G4;G5;G6 were subjected to a test of shear strength after one week, the groups G7;G8;G9;G10;G11;G12 were tested after six months (aged), being G1; G7 - restored without bleaching ; G2; G8 - bleached and restored after fourteen days; G3; G9 - bleached and restored at the same day; G4; G10 - bleached, treated with sodium ascorbate hydrogel of 10% and restored; G5; G11 - bleached, treated with sodium ascorbate hydrogel of 20% and restored and G6; G12 - bleached, treated with sodium ascorbate hydrogel of 40% and restored. The results of the shear test were subjected to two ANOVA’s criteria and Tukey's analysis to compare the scores (p≤ 0,05). The groups G1: 152,6N +- 21,2; G2: 183,2N +- 31,4; G5: 171,53N +- 20,6; G6: 179,9N +- 33,1 showed similar resistance to shear and the groups G3: 99,3N +- 33,9; G4: 101,3N +- 29,3 were statistically significant lower resistance. The second group had lower shear resistance, however maintained the same pattern of statistical difference between the groups. The aged groups G7: 98,1 +- 22,6; G8: 111,9 +- 34,0; G11: 91,9 +- 24,0; G12: 90,0 +- 13,1 showed lower shear resistance when compared to the non-aged. However, when compared between the aged, as well as between no-aged, the groups G9: 59,3 +- 19,9; G10: 59,7 +- 10,9 also showed lower resistance when compared to the others groups. We can conclude that the tooth bleaching with 35% hydrogen peroxide promoted reduction of the bond strength. In addition, treatment of the bleached enamel with 20% and 40% sodium ascorbate hydrogel allowed to reach values of bond strength similar of the enamel not bleached. / Após finalizar o tratamento de clareamento dentário os subprodutos da reação permanecem na estrutura dentária impedindo a correta polimerização das restaurações adesivas. O objetivo deste trabalho foi investigar os efeitos antioxidantes do hidrogel de ascorbato de sódio sobre o oxigênio residual na estrutura de esmalte bovino clareado com peróxido de hidrogênio e posteriormente restaurado com resina composta. Cento e vinte dentes bovinos foram divididos em 12 grupos (n=10), os grupos G1;G2;G3;G4;G5;G6 foram submetidos ao teste de cisalhamento após uma semana, os grupos G7;G8;G9;G10;G11;G12 foram testados após seis meses (envelhecimento), sendo G1;G7 - restaurado sem clareamento; G2;G8 - clareado e restaurado após 14 dias; G3;G9 - clareado e restaurado no mesmo dia; G4;G10 - clareado, tratado com hidrogel de ascorbato de sódio 10% e restaurado; G5;G11 - clareado, tratado com hidrogel de ascorbato de sódio a 20% e restaurado e G6;G12 - clareado, tratado com hidrogel de ascorbato de sódio a 40% e restaurado. Os resultados do teste de cisalhamento foram submetidos a ANOVA a 2 critérios e teste de Tukey para comparação das medias (p≤ 0,05). Os grupos G1: 152,6N +-­‐ 21,2; G2: 183,2N +-­‐ 31,4; G5: 171,53N +-­‐ 20,6; G6: 179,9N +-­‐ 33,1 apresentaram resistência ao cisalhamento semelhante e os grupos G3: 99,3N +-­‐ 33,9; G4: 101,3N +-­‐ 29,3 apresentaram resistência inferior estatisticamente significativa. O segundo grupo apresentou menor resistência ao cisalhamento porém, mantive o mesmo padrão de diferença estatística entre os grupos. Os grupos envelhecidos G7: 98,1N +- 22,6; G8: 111,9N +- 34,0; G11: 91,9N +- 24,0; G12: 90,0N +- 13,1 apresentaram menor resistência ao cisalhamento quando comparados aos não envelhecidos. No entanto, quando comparado entre os envelhecidos, assim como nos não envelhecidos, os grupos G9: 59,3N +- 19,9; G10: 59,7N +- 10,9 também apresentaram resistência inferior comparado aos demais grupos. Podemos concluir que o clareamento dental com o peróxido de hidrogênio a 35% promoveu redução da resistência adesiva. Além disso, o tratamento do esmalte clareado com hidrogel de ascorbato de sódio a 20% e a 40% permitiu alcançar valores de resistência de união similar ao esmalte não clareado.
14

Clareamento dental em pacientes com sensibilidade: efeito do uso prévio de dentifrícios dessensibilizantes

Amorim, Ana Carla Pimentel de, 92-99140-3791 20 March 2017 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-08-25T13:34:12Z No. of bitstreams: 2 Dissertação - Ana Carla P. Amorim.pdf: 2202692 bytes, checksum: 5d85f81ed9e97fb1a99fed106d844eff (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-08-25T13:34:25Z (GMT) No. of bitstreams: 2 Dissertação - Ana Carla P. Amorim.pdf: 2202692 bytes, checksum: 5d85f81ed9e97fb1a99fed106d844eff (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-08-25T13:34:25Z (GMT). No. of bitstreams: 2 Dissertação - Ana Carla P. Amorim.pdf: 2202692 bytes, checksum: 5d85f81ed9e97fb1a99fed106d844eff (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-20 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / One of the alternatives proposed to decrease the sensitivity generated by the bleaching procedure is the continuous use of desensitizing dentifrices. This study aimed to evaluate the efficacy of 5% potassium nitrate and sodium fluoride dentifrices in reducing the sensitivity related to tooth whitening. For this, a double blind, randomized and parallel clinical study (examiner and patient) was performed. Thirty-eight patients older than 18 years old and with a history of sensitivity were randomly assigned to two treatments: PNG, which used the dentifrice with potassium nitrate plus sodium fluoride, and SFG, which used the dentifrice only with sodium fluoride. Sensitivity evaluation was performed at different times and between PNG and SFG treatments. We used the five-point verbal scale (NRS) and visual analogue scale (VAS) to measure dental sensitivity, so that temporal and inter-treatment differences were assessed using the Wilcoxon Signed Rank and U Mann-Whitney tests , as well as ANOVA. The post hoc Tukey test was used to evaluate the frequency of pain events in different dental elements. The analysis of dental color variation between the initial and final times was performed using the ANOVA test. In all statistical tests, the level of significance was 5%. The methods used to measure the dental color were the Vita Classical scale and the Easy Shade Spectrophotometer. The analyzes showed no significant differences (p> 0.05) in the efficacy of booth PNG and SFG treatments to reduce the dental sensitivity according to NRS and VAS scales. Significant color change of approximately seven color guide units in the Vita Classical scale as well as the spectrophotometer results showed that there was no significant difference between the effectiveness of dental bleaching from both treatments. Therefore, the treatments had similar efficacy to reduce the post-bleaching dental sensitivity and did not influence the success of dental whitening. / Umas das alternativas propostas para diminuir a sensibilidade gerada pelo procedimento clareador é o uso contínuo de dentifrícios dessensibilizantes. Este estudo teve como objetivo avaliar a eficácia de dentifrícios à base de nitrato de potássio a 5% e fluoreto de sódio na redução da sensibilidade relacionada ao clareamento dental. Para isto, foi realizado um estudo clínico do tipo duplo cego (examinador e paciente), randomizado e paralelo. 38 pacientes maiores de 18 anos com histórico de sensibilidade foram aleatoriamente alocados em dois tratamentos: GNP, que utilizou o dentifrício com nitrato de potássio e fluoreto de sódio, e GFS, que utilizou o dentifrício somente com fluoreto de sódio. A avaliação da sensibilidade foi realizada em diferentes tempos e entre os tratamentos GNP e GFS. Para medir a sensibilidade dentária, foram usadas a escala verbal de cinco pontos (NRS) e a escala análoga visual (VAS), de modo que as diferenças temporais e entre os tratamentos foram avaliadas usando os testes Wilcoxon Signed Rank e U de Mann-Whitney, assim como ANOVA. O teste de Tukey post hoc foi usado para avaliar a frequência dos eventos de dor nos diferentes elementos dentais. A análise da variação de cor dental entre os tempos inicial e final foi realizada através do teste ANOVA. Em todos os testes estatísticos o nível de significância foi de 5%. Os métodos para aferir a cor dental foram: escala Vita Classical (Método subjetivo) e o Espectrofotômetro Easy Shade (Método objetivo). As análises demonstraram não haver diferenças significativas (p > 0,05) nos tratamentos GNP e GFS com relação à redução da sensibilidade pós clareamento e que os agentes dessensibilizantes não influenciaram na efetividade do procedimento clareador, visto que houve uma mudança significativa de cor de aproximadamente sete unidades de guia de cor na escala Vita Classical e no espectrofotômetro.
15

Dentina cariada como substrato para restaurações adesivas – uma análise por elementos finitos

Martinho, Roberto Luiz de Menezes 20 January 2016 (has links)
Submitted by Bianca Neves (oliveirabia1@ymail.com) on 2016-04-19T20:31:01Z No. of bitstreams: 1 Dissertação - Roberto Luiz de Menezes Martinho.pdf: 1158506 bytes, checksum: 1316e884d471671c7dc1531f1a327c8f (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-04-28T14:45:44Z (GMT) No. of bitstreams: 1 Dissertação - Roberto Luiz de Menezes Martinho.pdf: 1158506 bytes, checksum: 1316e884d471671c7dc1531f1a327c8f (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-04-28T14:52:40Z (GMT) No. of bitstreams: 1 Dissertação - Roberto Luiz de Menezes Martinho.pdf: 1158506 bytes, checksum: 1316e884d471671c7dc1531f1a327c8f (MD5) / Made available in DSpace on 2016-04-28T14:52:40Z (GMT). No. of bitstreams: 1 Dissertação - Roberto Luiz de Menezes Martinho.pdf: 1158506 bytes, checksum: 1316e884d471671c7dc1531f1a327c8f (MD5) Previous issue date: 2016-01-20 / The aim of this study was to analyze, using finite element method (FEM), stresses generated in composite restorations on different dentin substrates: infected carious dentin, affected carious dentin and sound dentin. Three-dimensional model composed by a mandibular left first molar, showing a cavitated carious lesions in dentin on the occlusal surface was developed by the scanner Roland MDX-20 3D Milling, Dr. Picza® 3 and Rhinoceros 5.0 softwares and finite element analysis was obtained by NeiNastran® 10.0.3.7 software. The experiment included four distinct situations: Case 1) Cavitated carious lesion in enamel/dentin, not restored (infected dentin thickness: 1.25 mm; affected dentin: 0.75mm); Case 2) Composite restoration (2.0mm) performed on infected and affected carious dentin (infected dentin: 0.75mm; affected dentin: 0.75mm); Case 3) Composite restoration (2.0mm) held on affected carious dentin (affected dentin: 0.75mm); Case 4) Resin restoration (2.0mm) performed on sound dentin. In all simulations enamel thickness was 1.5 mm, and in all restored cases, a thickness of 0.5mm of affected and infected carious dentin was removed from dentinoenamel junction. The affected dentin Poisson's ratio was tested in: hypothesis 1 in 0.45, and assumed a value of 0.25 in hypothesis 2. The total load on models was 100 N, by applying four force points distributed over the adhesive restoration. Results were interpreted based on a color map and maximum tensile stresses obtained were compared using non-parametric analysis (Kruskal-Wallis test, followed by Dunn's test, and Mann-Whitney test). In all simulations, the regions of restoration that focused greater tensile stresses were the area next to dentinoenamel junction and the floor/base restoration. When infected dentin was maintained as substrate, the build-up of stresses in these restoration regions was significantly higher. Maintaining only affected carious dentin did not significantly alter stresses generated in restoration when compared to sound dentin (p> 0.05). The result of this biomechanical analysis strengthens the favorable evidence to the maintenance of affected carious dentin under restorations. / Este trabalho teve o objetivo de analisar, por meio da metodologia de elementos finitos (MEF), as tensões geradas em restaurações de resina realizadas sobre diferentes substratos dentinários: dentina cariada infectada, dentina cariada afetada e dentina sadia. O modelo tridimensional composto por um primeiro molar inferior esquerdo, apresentando lesão cariosa cavitada em dentina na face oclusal, foi desenvolvido por meio do scanner Roland MDX-20 3D Milling e dos softwares Dr. Picza® 3 e Rhinoceros® 5.0 e a análise MEF foi obtida pelo software NeiNastran® 10.0.3.7. O experimento contou com quatro situações distintas: Caso 1) Lesão cariosa cavitada em esmalte/dentina, não restaurada (espessura da dentina infectada: 1,25mm; dentina afetada: 0,75mm); Caso 2) Restauração em resina (2,0mm) realizada sobre dentina cariada infectada e afetada (dentina infectada: 0,75mm; dentina afetada: 0,75mm); Caso 3) Restauração em resina (2,0mm) realizada sobre dentina cariada afetada (dentina afetada: 0,75mm); Caso 4) Restauração em resina (2,0mm) realizada sobre dentina sadia. Em todas as simulações a espessura do esmalte foi de 1,5mm, e em todos os casos de restauração, a dentina cariada infectada e afetada foi removida da junção amelodentinária, numa espessura de 0,5mm. O coeficiente de Poisson da dentina afetada foi testado na hipótese 1 com valor de 0,45, e na hipótese 2 com valor de 0,25. A carga total aplicada nos modelos foi de 100 N, através da aplicação de 4 pontos de força distribuídos sobre a restauração adesiva. Os resultados foram interpretados com base no mapa de cores e as tensões máximas de tração obtidas foram comparadas por meio de análise não-paramétrica (teste de Kruskall-Wallis, seguido do teste de Dunn; e teste de Mann-Whitney). Em todas as simulações analisadas, as regiões da restauração que concentraram maiores tensões de tração foram a área próxima à junção amelo-dentinária e o assoalho/base da restauração. Quando a dentina infectada foi mantida como substrato, o acúmulo de tensões nestas regiões da restauração foi significativamente maior. A manutenção apenas da dentina cariada afetada não alterou significativamente as tensões geradas na restauração, quando comparada à dentina sadia (p>0,05). O resultado desta análise biomecânica reforça as evidências favoráveis à manutenção da dentina cariada afetada sob restaurações.
16

Avaliação da atividade antimicrobiana e citotóxica da biflorina frente a micro-organismos orais e a uma linhagem de célula cancerígena da cavidade bucal

Monteiro, Julie Marie Martins 29 May 2015 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-08T20:01:21Z No. of bitstreams: 1 Dissertação - Julie Marie Martins Monteiro.pdf: 996366 bytes, checksum: 7736bdc6fce423bd155ddb42d5bb7df9 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-08T20:01:34Z (GMT) No. of bitstreams: 1 Dissertação - Julie Marie Martins Monteiro.pdf: 996366 bytes, checksum: 7736bdc6fce423bd155ddb42d5bb7df9 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-08T20:03:17Z (GMT) No. of bitstreams: 1 Dissertação - Julie Marie Martins Monteiro.pdf: 996366 bytes, checksum: 7736bdc6fce423bd155ddb42d5bb7df9 (MD5) / Made available in DSpace on 2016-06-08T20:03:17Z (GMT). No. of bitstreams: 1 Dissertação - Julie Marie Martins Monteiro.pdf: 996366 bytes, checksum: 7736bdc6fce423bd155ddb42d5bb7df9 (MD5) Previous issue date: 2015-05-29 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / Phytochemical investigations led to the isolation and characterization of biflorin that among the compounds already isolated from Capraria biflora, showed promise with a powerful antimicrobial and antitumor activity. Therefore, the aim of this study was to evaluate the antimicrobial activity of biflorin on the oral cavity microorganisms and cytotoxic activity on cancer cell lineage of the oral cavity. The screening of antimicrobial activity biflorin was performed by diffusion technique in agar with the microorganisms Streptococcus mutans ATCC25175, Streptococcus salivarius ATCC7073, Streptococcus oralis ATCC10557 and Lactobacillus paracasei ATCC335. The quantification of the antimicrobial activity was performed by broth microdilution technique to determine the minimum inhibitory concentration (MIC). To evaluate the cytotoxicity of cancer lineage of the oral cavity was used cell line CAL-27 and the Alamar blue assay. In the agar diffusion test, biflorin presented antimicrobial activity against all evaluated microorganisms. The greatest antimicrobial activity was observed in trials with Lactobacillus paracasei and lower in trials with Streptococcus salivarius. Whereas biflorin was active against all tested micro-organisms, it determined the minimum inhibitory concentration. In the microdilution test biflorin showed lower MIC against Streptococcus mutans (MIC = 0,70μg/mL) and Streptococcus salivarius (MIC 3,125 μg/mL). While the 2% chlorhexidine was effective in its lower dilution (0,015%) of all tested bacteria. In Alamar blue cytotoxicity assay, the IC50 value of biflorin on the CAL 27 in 72 hours was 3.69 (3.17 to 4.30μM/mL) and Doxorubicin (control) was 0.039 (0.036- 0.088 μM/mL).The results suggest that biflorin can be incorporated in dental applications and products for the treatment of cancers of the oral cavity, but it is necessary to continue the research in this area with this substance / Investigações fitoquímicas levaram ao isolamento e caracterização da Biflorina que dentre os compostos já isolados da Capraria biflora, mostrou-se promissora com uma potente atividade antimicrobiana e antitumoral. Portanto, o objetivo deste estudo foi avaliar a atividade antimicrobiana da biflorina sobre micro-organismos da cavidade bucal e atividade citotóxica sobre linhagem de célula cancerígena da cavidade bucal. A triagem da atividade antimicrobiana da biflorina foi realizada através da técnica de difusão em ágar com os microorganismos Streptococcus mutans ATCC25175, Streptococcus salivarius ATCC7073, Streptococcus oralis ATCC10557 e Lactobacillus paracasei ATCC335. A quantificação desta atividade antimicrobiana foi realizada pela técnica de microdiluição em caldo para determinação da concentração inibitória mínima (CIM). Para avaliação da citotoxicidade sobre linhagem cancerígena da cavidade bucal foi utilizada a linhagem celular CAL-27 e o ensaio de Alamar blue. No teste de difusão em ágar, a biflorina apresentou atividade antimicrobiana frente atodos os micro-organismos avaliados. A maior atividade antimicrobiana foi observada nos ensaios com o Lactobacillus paracasei e a menor nos ensaios com Streptococcus salivarius. Considerando que a biflorina foi ativa frente a todos os micro-organismos testados, determinou-se a concentração inibitória mínima. No teste de microdiluição a biflorina apresentou menor CIM frente ao Streptococcus mutans (MIC=0,70 μg/mL) e Streptococcus salivarius (MIC 3,125 μg/mL). Enquanto a clorexidina a 2% foi eficaz em sua menor diluição (0,015%) sobre todas as bactérias testadas. No teste de citotoxicidade do Alamar blue, o valor da IC50 da Biflorina sobre a CAL-27 em 72 horas foi de 3.69 (3.17 – 4.30μM/mL) e a Doxorrubicina (controle) foi 0.039 (0.036-0.088μg/mL). Os resultados sugerem que a biflorina pode ser incorporada a produtos de uso odontológico e para o tratamento de neoplasias da cavidade oral, porém é necessário dar continuidade aos estudos com esta substância nesta área
17

Efeito do reuso sobre as características de superfície e da composição química de instrumentos de NiTi

Bastos, Mariana Mena Barreto 01 March 2016 (has links)
Submitted by Inês Marinho (bele_ballet@hotmail.com) on 2016-06-13T14:27:04Z No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-13T19:55:58Z (GMT) No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-13T19:59:05Z (GMT) No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) / Made available in DSpace on 2016-06-13T19:59:05Z (GMT). No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) Previous issue date: 2016-03-01 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / Endodontic instruments NiTi were analyzed using a Scanning Electron Microscope (SEM) coupled to a Spectrometer X-ray by Energy Dispersive (EDAX), before and after use, in order to assess the presence of defects, deformations and analyze its chemical composition. To this end, thirty instruments were divided into 3 groups, 10 Protaper Next®X1 files (PNX1), 10 Protaper Next®X2 files (PNX2) and 10 WoveOne® files (WO), which were electromicrograph 250-fold increase in tip region, the tip of 2mm and 4mm. The instruments were used in the preparation of 60 simulated canals blocks made of polyester resin. Initially we performed the catheterization with K file # 10 and the length (CT), followed by instrumentation according to each group. Group 1: 10 blocks of simulated canals were instrumented with ProTaper NEXT® system using the file X1 to instrumentation of the cervical and middle third and X2 to the apical third. Group 2: 10 blocks were instrumented with the WaveOne® 25.08 Primary file system according to the manufacturer's recommendations. The instruments were first used one time and then reused 2 times, always in new simulated channels. The files were washed in ultrasonic tank and subjected to new microscopic analysis by SEM and EDAX. Then the elétromicrografias were taken at the tip of the instrument, the tip of 2mm and 4mm, with an increase of 250X. To establish the scores were observed the presence of jagged edges, grooves, wells and burrs. Each instrument when compared with each other in the same length over the three days of use showed no statistical difference in relation to the increase in defects (p> 0.05). Regarding the scores, statistical analysis of the results showed that only WO files showed a higher number of defects and deformations in the length of 4mm, the third time evaluation of the study (p <0.05). It has been observed in the analysis of the chemical elements that PNX1 files showed significant losses compared to the average Ni before use and after the third application (p <0.01); PNX2 the files and WO significant loss of Ni in the three days of use (p <0.01). Regarding Ti, PNX1 files in no significant loss during use (p> 0.05), but the files PNX2 showed significant loss between before and the first instrumentation and between the first and third use (p <0, 01). In WO files, a significant loss when compared before and after the first use and prior to the third use. Thus, reuse demonstrated that the instruments had all defects and deformations at some length and time of the study but not increased with use. Loss occurred only in ProTaper Ni NEXT® X1 files after use and the ProTaper files NEXT® X2 and WaveOne® was no loss of Ni and Ti after 3 uses. / Instrumentos endodônticos de NiTi foram analisados por meio de um Microscópio Eletrônico de Varredura (MEV) acoplado a um Espectômetro de Raio X por Energia Dispersiva (EDAX), antes e após o uso, com o objetivo de avaliar a presença de defeitos, deformações e analisar a sua composição química. Para isso, trinta instrumentos foram separados em 3 grupos, 10 limas ProTaper Next®X1(PNX1), 10 limas ProTaper Next®X2 (PNX2) e 10 limas WoveOne® (WO), as quais foram Elétromicrografados com aumento de 250 vezes, na região da ponta, 2mm e a 4mm da ponta. Os instrumentos foram utilizados no preparo de 60 blocos de canais simulados fabricados em resina poliéster. Inicialmente foi realizado o cateterismo com lima tipo K #10 e no comprimento de trabalho (CT), seguido pela instrumentação de acordo com cada grupo. Grupo 1: 10 blocos de canais simulados foram instrumentados com o sistema ProTaper Next®, utilizando a lima X1 para instrumentação do terço cervical e médio e a X2 para o terço apical. O grupo 2: 10 blocos foram instrumentados com a lima Primary 25.08 do sistema WaveOne® de acordo com as recomendações do fabricante. Os instrumentos foram utilizados primeiramente 1 vez e depois reutilizados 2 vezes, sempre em canais simulados novos. A limas foram lavadas em cuba ultrassônica e submetidas a nova análise microscópica pelo MEV e EDAX. Em seguida, as elétromicrografias foram tomadas na ponta do instrumento, a 2mm e a 4mm da ponta, com aumento de 250X. Para estabelecimento dos scores foram observados a presença de bordas irregulares, ranhuras, microcavidades e rebarbas. Cada instrumento quando comparados entre si no mesmo comprimento durante os três tempos de utilização não apresentaram diferença estatística em relação ao aumento dos defeitos (p>0,05). Em relação aos escores, a análise estatística dos resultados evidenciou que somente as limas WO apresentaram maior número de defeitos e deformações no comprimento de 4mm, nos 3 tempos de avaliação do estudo (p< 0.05). Foi observado na análise dos elementos químicos que as limas PNX1 apresentaram perdas significativas de Ni quando comparada as médias antes do uso e após a terceira utilização (p<0,01); nas limas PNX2 e WO houve perda significativa de Ni nos três tempos do uso (p<0,01). Em relação ao Ti, nas limas PNX1 não houve perda significativa ao longo do uso (p>0,05), porém, nas limas PNX2 apresentou perda significativa entre antes e a primeira instrumentação e entre o primeiro e terceiro uso (p<0,01). Nas limas WO, houve perda significativa quando comparamos antes e após a primeira utilização e antes com o terceiro uso. Assim, o reuso demonstrou que os instrumentos apresentaram todos os defeitos e deformações em algum comprimento e momento da pesquisa porém não aumentaram conforme o uso. Ocorreu perda apenas de Ni nas limas ProTaper Next® X1 após o uso e nas limas ProTaper Next® X2 e WaveOne® houve perda de Ni e Ti após as 3 utilizações.
18

Extrusão de debris, desvio apical, capacidade de centralização e área de desgaste promovidos por instrumentos rotatórios e reciprocantes indicados para canais amplos

Costa, Elielton Lima 09 March 2016 (has links)
Submitted by Izabel Monteiro (izabel_22@hotmail.com) on 2016-06-17T13:48:46Z No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-23T20:16:09Z (GMT) No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-23T20:21:23Z (GMT) No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) / Made available in DSpace on 2016-06-23T20:21:23Z (GMT). No. of bitstreams: 1 Dissertação - Elielton LIma Costa.pdf: 1439249 bytes, checksum: 0d4b3b7c30523b7ea83786adbcd441bc (MD5) Previous issue date: 2016-03-09 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / The aim of the study was to evaluate the extrusion of debris, apical transportation, centering ability and wear area further by Rotary and reciprocating instruments used in large root canals. Forty-five mandibular premolar with only single-rooted teeth and single canal and apical diameter largest that 300 μm. In order of the standardization the samples were fixed in acrylic resin and placed in styrofoam platform. Cone-beam computed tomography analysis was perfomed before and after instrumentation for apical third images acquisition for to appoint the anatomic and surgical diameter. The extruded debris during instrumentation was collected into pre-weighed Eppendorf tubes. The mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers’ instructions. Group 1 (Protaper Universal - PTU): All PTU instruments were used to the full length of the canals according to the manufacturer’s instructions using a gentle in-and-out motion. The instrumentation sequence was S1, S2, F1, F2, F3, F4 and F5. Group 2 (Protaper Next - PTN): All PTN instruments were used to the full length of the canals according to the manufacturer’s instructions using a gentle in-and-out motion. The instrumentation sequence was X1, X2, X3, X4 and X5. Group 3 (Reciproc R50 – R50): Reciproc file was used in a reciprocating, slow in-and-out pecking motion according to the manufacturer’s instructions. The flutes of the instrument were cleaned after 3 in-and-outmovements (pecks). In each sample, a total of 1-mL distilled water was used as the irrigant solution between files. Before weighing the dry debris, the tubes were stored in na incubator at 70 °C for 5 days to evaporate the distilled water. The quantitative evaluation of apically extrued debris was analyzed by weight difference before and after instrumentation. Apical transportation, centering ability and wear area were analyzed for images of the cone-beam computed tomography worked in the software OsiriX. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test). The results showed that the group PTN produced significantly more debris compared with both groups (P<0.01). All groups had apical transportation values in the 2°, 3° e 4° mm apical, with no significant difference among them (P>0.05). No technique had perfect centering abitity (=1.0). the group R50 showed largest wear area, with significant difference (P<0.05) compared with both groups. In conclusion, under the condition of this study, the group PTN produced more debris compared with both groups. The R50 intrumentation showed largest wear area that both Group PTN and PTU, with significant difference. All technique showed no had perfect centering abitity and showed apical transportation, no with significant difference between them. / O objetivo do presente trabalho foi avaliar o extravasamento apical de debris, desvio apical, capacidade de centralização e área de desgaste promovidos por sistemas de instrumentação rotatórios e reciprocante indicados para canais amplos. Foram selecionados 45 pré-molares inferiores com único canal e raiz e diâmetro apical maior que 300 μm. Com intuito de padronização das amostras fixou-se os espécimes em base de resina acrílica e posicionou-os em plataforma de isopor. Os espécimes foram submetidos a tomografia computadorizada antes e após a instrumentação para determinação do diâmetro anatômico e cirúrgico a fim de favorecer as mensurações do estudo. Durante a instrumentação os dentes foram fixados em frascos de vidro para a pesagem dos debris apicais. Os dentes selecionados foram distribuídos em três grupos (n=15) e instrumentados de acordo com as indicações dos respectivos fabricantes dos sistemas. Grupo I (Protaper Universal - PTU): todos os instrumentos, S1, S2, F1, F2, F3, F4 e F5, foram inseridos no comprimento de trabalho real com avanço progressivo e movimentos de vai e vem no interior dos canais. Grupo II (Protaper Next - PTN): instrumentos X1, X2, X3, X4, X5 foram inseridos no comprimento de trabalho real com avanço progressivo e movimentos de vai e vem no interior dos canais. Grupo III (Reciproc – R50): Reciproc R50 foi inserido progressivamente no canal, inseria-se e removia-se o instrumentos e limpava-o com gaze. Esse procedimento foi repetido até o alcance do comprimento de trabalho, em três avanços. Utilizou-se 1 mL de água bidestilada como solução irrigante a cada troca de instrumento. Os frascos de vidro contendo debris foram armazenados em estufa a 70 °C por 5 dias até a secagem completa da água. Determinou-se a quantidade de debris pelo cálculo da diferença dos pesos iniciais e finais dos frascos. As imagens tomográficas foram manipuladas no programa OsiriX a fim de se determinar o desvio apical, capacidade de centralização e área de desgaste. Os dados foram submetidos ao teste não-paramétrico de Kruskal-Wallis e teste de Múltiplas Comparações de Dunn. Os resultados do extravasamento de debris mostraram que o grupo da PTN apresentou maior quantidade de extravasamento, com diferença estatisticamente significante (P<0.01) em relação aos outros grupos. Todas as técnicas apresentaram desvio apical nos 2°, 3° e 4° milímetros apicais, porém sem diferença estatística significante (P>0.05). Nenhuma técnica apresentou centralização perfeita (=1.0). O grupo da R50 apresentou maior área de desgaste, com diferença estatisticamente significante (P<0.05) em relação ao demais grupos. Com base na metodologia empregada e nos resultados obtidos, concluiu-se que o sistema PTN apresentou estatisticamente maior quantidade de extravasamento de debris quando comparado aos demais grupos. O grupo R50 apresentou maior área de desgaste que os grupos PTN e PTU com diferença estatística significativa. Todas as técnicas tiveram tendência a centralização e apresentaram desvio apical, porém sem diferenças estatísticas entre si.
19

Distribuição de tensões em coroas totais com sistema metal-free por meio do método de elementos finitos

Lima, Liliane Motta de 20 January 2016 (has links)
Submitted by Gábia Leite (gabya.leite@gmail.com) on 2016-06-24T15:24:45Z No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T14:45:15Z (GMT) No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T14:47:43Z (GMT) No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) / Made available in DSpace on 2016-07-05T14:47:43Z (GMT). No. of bitstreams: 1 Dissertação - Liliane Lima.pdf: 2018746 bytes, checksum: c838a76be3c2ba884af2ac999bd5b13b (MD5) Previous issue date: 2016-01-20 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This study compared the stress distribution between three-dimensional lower first molar crowns of indirect resin Lava Ultimate (3M ESPE) (LU) and ceramic IPS e.max CAD (Ivoclar Vivadent) (Emax) against the application of functional load. Three variables were studied by the method of finite elements: the type and thickness of restorative material (1 or 2 mm) as well as the direction of the applied load (axial or oblique). On a modeling software (Rhinoceros; 5.0, Robert Mcneel & associates, USA), CAD models of total crown preparation were generated with different thicknesses of occlusal wear and their indirect restorations. Then in Femap® (10.2, Siemens PLM Software, USA) software, the construction of the finite element mesh was made. After checking the quality of this, the elastic modulus and Poisson's ratio of the tested materials were inserted in the program. After, in Nei Nastran software (10.0.3.7, NEi Software, USA), it was carried out the study of stress distribution from the simulation of models with a load of 200 N on the central fossa region and near the tip of the distobuccal cusp ridge, corresponding to a lower first molar crown. Data analysis was based on a qualitative description of the generated images and also on the values of maximum principal stress of each CAD model. According to the results, the LU crowns behaved as transmission structures of stresses and the complex tooth/restoration as a single block in which stress was distributed more evenly. In Emax crowns, however, the tensile stresses concentrated particularly along the thickness of the material. The more favorable stress distribution was obtained with the 2 mm thickness crowns in an axial occlusal load application, especially for the LU material. / O presente estudo comparou a distribuição de tensões entre coroas de primeiro molar inferior tridimensionais de resina laboratorial Lava Ultimate; 3M ESPE (LU) e de cerâmica IPS e.max CAD; Ivoclar Vivadent (Emax) frente à aplicação de carga funcional. Três variáveis foram estudadas pelo método de elementos finitos: o tipo e a espessura de material restaurador (1 e 2 mm), assim como a direção da carga aplicada (axial e oblíqua). Em um programa modelador (Rhinoceros®; versão 5.0, Robert McNeel & Associates, USA), foram gerados modelos CAD (desenhados com auxílio do computador) de preparos de coroa total com diferentes espessuras de desgaste oclusal e suas respectivas restaurações indiretas. Em seguida, no software Femap® (versão 10.2, Siemens PLM Software, USA), realizou-se a construção da malha de elementos finitos e, após a verificação da qualidade desta, o módulo de elasticidade e o coeficiente de Poisson dos materiais testados foram inseridos no programa. Posteriormente, no software Nei Nastran (versão 10.0.3.7, NEi Software, USA), realizou-se o estudo da distribuição de tensões a partir da simulação computadorizada dos modelos com um carregamento de 200 N nas regiões de fossa central e vertente triturante da cúspide médio-vestibular, correspondentes a um primeiro molar inferior. A análise dos dados baseou-se em uma descrição qualitativa das imagens geradas e nos valores obtidos das tensões principais máximas de cada modelo CAD. De acordo com os resultados, as coroas de LU se comportaram como estruturas transmissoras de tensões e o complexo dente/restauração como um bloco único no qual as tensões foram distribuídas de forma mais homogênea. Nas coroas de Emax, ao contrário, as tensões de tração se concentraram, sobretudo, ao longo da espessura do material. A distribuição de tensões mais favorável foi obtida com as coroas de 2 mm de espessura oclusal em uma aplicação axial da carga, principalmente para o material LU.
20

Efeito do gel hemostático de cloreto de alumínio 25% na resistência de união dentinária com diferentes sistemas adesivos

Nascimento Sobrinho, Kleyver do 25 February 2016 (has links)
Submitted by Inês Marinho (bele_ballet@hotmail.com) on 2016-06-24T13:59:54Z No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T16:05:44Z (GMT) No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-07-05T16:08:27Z (GMT) No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) / Made available in DSpace on 2016-07-05T16:08:27Z (GMT). No. of bitstreams: 1 Dissertação - Kleyver do Nascimento Sobrinho.pdf: 1970241 bytes, checksum: 9563817a411ce59d3b1fe44712e1f864 (MD5) Previous issue date: 2016-02-25 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / The aim of this study was to evaluate, through microshear bond strength test (μSBS), the influence of a hemostatic solution (Aluminum Chloride 25%) to the bond strength on dentin. Thirty-six (36) bovine incisors free of any structural defects were prepared and randomly divided into 6 test groups (n = 6): SB - adhesive system Scotchbond Multi-purpose (3M/ESPE); CS – Adhesive system Clearfil SE Bond (Kuraray); SU – adhesive system Single Bond Universal (3M/ESPE); SBC, CSC and SUC groups received application of the same adhesives systems used in SB, CS and SU, respectively, with the prior application of aluminum chloride 25% hemostatic solution. Following, a nanohybrid composite Filtek Z350 XT (3M/ ESPE) was applied to the dentin surface using silicon tubes (Tygon) in order to obtain composite resin cylinders in each specimen, a total of 18 cylinders in each group. The specimens were maintained at 37 °C for 7 days and then submitted to μSBS test. The bond strength values were statistically analyzed for normality by Shapiro-Wilk test and compared using two-way ANOVA and Tukey's test at a significance level of 0.05, which showed no statistically significant differences regarding the type of adhesive and contamination. In this sense, the use of aluminum chloride 25% did not influence significantly the performances of the adhesives used on dentin in this study. / O objetivo deste estudo foi avaliar, através do teste de microcisalhamento (μSBS), a influência de uma solução hemostática (Cloreto de Alumínio 25%) na resistência de união à dentina. Trinta e seis (36) dentes incisivos bovinos isentos de quaisquer defeitos estruturais foram preparados e divididos aleatoriamente em 6 grupos (n=6) teste: SB – Sistema adesivo ScotchBond Multi-uso (3M/ESPE); CS – Sistema adesivo Clearfil SE Bond (Kuraray); SU – Sistema adesivo Single Bond Universal (3M/ESPE); os grupos SBC, CSC e SUC receberam a aplicação dos mesmos sistemas adesivos empregados nos grupos SB, CS e SU, respectivamente, no entanto, com a aplicação prévia da solução hemostática à base de Cloreto de Alumínio 25%. Na sequência, o compósito nanohíbrido Filtek Z350 XT (3M/ESPE) foi aplicado à superfície dentinária através de tubos de silicone (Tygon) de maneira a obter cilindros do compósito resinoso em cada espécime, totalizando 18 cilindros em cada grupo. Os espécimes foram mantidos em estufa (37ºC) durante 7 dias e em seguida, submetidos ao teste mecânico. Os valores de resistência de união foram analisados estatisticamente para normalidade através do teste Shapiro-Wilk e comparados usando-se ANOVA two-way e Teste de Tukey em um nível de significância de 0.05, os quais não demonstraram diferença estatística significante em relação ao tipo de adesivo e ao tipo de contaminação. Neste sentido, o uso do Cloreto de Alumínio 25% não influenciou de maneira significativa, em dentina, o desempenho dos sistemas adesivos utilizados neste estudo.

Page generated in 0.0419 seconds