• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 15
  • 12
  • 11
  • 10
  • 10
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.
12

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.
13

Análise biomecânica de implantes odontológicos / Biomechanical Analysis of Dental Implants

Silva, Naiara Cristina da 09 March 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / It was objectified in this dissertation to analyze the distribution of the stress and displacements in the bone-implant interface, using the finite element method. The implants had been analyzed in two distinct situations: put directly in the two bone layers, cortical and trabecular, simulating the situation of immediate load, previous to osseointegration, and with the implants involved by a denser bone layer simulating the occurrence of the osseointegration. The geometry of the bone layers was obtained by means of computerized cat scan and the format of the implants and the prosthetic components had been supplied by the Neodent (Curitiba, Brazil). The variables analysed had been: geometry of the implants (cylindrical and taper), abutment (internal hexagon and morse taper) and the positioning of the implants in relation to the alveolar bone boards (buccaly and palatine). With this, 16 groups of analysis were formed, for which bidimensional models of the alveolus of extration of an upper central incisor had been constructed, simultaneously with the geometry of the implants, for the numerical simulation. The results of bigger relevance had been: the Von Mises stresses, principal stress (maximum and minimum) and the shear stresses, as well as the relative displacements presented by the bone-implant structure. Through the analyses, one concluded that different implant geometries adjust themselves better to each situation (immediate load and osseointegrated implant), and that the Titamax CM implant, of cylindrical format with prosthetic connection, morse taper, in palatine position was the one that best adapted itself. The found values can lead to a better understanding of the biomechanics around the implants. Despite of being a preliminary study, the work supplies subsidies for the accomplishment of future researches, since the methodology used can be applied in a variety of similar cases found in the Implantology. / Objetivou-se nesta dissertação analisar a distribuição das tensões e deslocamentos na interface osso-implante, utilizando o método dos elementos finitos. Os implantes foram analisados em duas situações distintas: assentados diretamente nas duas camadas ósseas, cortical e trabecular, simulando a situação de carga imediata, anterior a osseointegração; e com os implantes envolvidos por uma camada óssea mais densa simulando a ocorrência da osseointegração. A geometria das camadas ósseas foi obtida por meio de tomografia computadorizada. O formato dos implantes e componentes protéticos foram fornecidos pela Neodent (Curitiba, Brasil). As variáveis analisadas foram: geometria dos implantes (cilíndrico e cônico), pilar (hexágono interno e cone morse) e o posicionamento dos implantes em relação às tábuas ósseas alveolares (vestibularizado e palatinizado). Com isto formou-se 16 grupos de análise, para os quais foram construídos modelos bidimensionais do alvéolo de extração de um incisivo central superior, conjuntamente com as geometrias dos implantes, para a simulação numérica. Os resultados de maior relevância foram: as tensões de Von Mises, tensões principais (máximas e mínimas) e as tensões cisalhantes, bem como os deslocamentos relativos apresentados pela estrutura osso-implante. Por meio das análises concluiu-se que, diferentes geometrias de implantes se ajustam melhor a cada situação (carga imediata e implante osseointegrado), e que o implante Titamax CM, de formato cilíndrico com conexão protética cone morse posicionado palatinizado, foi o que melhor adaptou-se. Os valores encontrados podem levar a um melhor entendimento da biomecânica ao redor dos implantes. Apesar de ser um estudo preliminar, o trabalho realizado fornece subsidio para a realização de pesquisas futuras, pois a metodologia utilizada pode ser empregada em uma variedade de casos similares encontrados na implantodontia. / Mestre em Engenharia Mecânica
14

Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse

Santos, Vanessa Tavares de Gois 17 February 2014 (has links)
Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE / Objective: Examine the fatigue resistance of the joint implant-abutment, in straight and anatomical types, submitted to cyclic loads. Material and methods: We used 37 implants (3.75 x 11mm) with morse taper system and 37 abutments, divided into two groups (n = 16: straight abutment, n=21 anatomical abutment, Neodent® Curitiba, Paraná, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. Three sets implant-abutment of each group were subjected to bending tests to determine the maximum load resistance of the samples, which served as a parameter to measure the cyclic tests. We evaluated number of cycles, load and bending moment of the samples. The Fisher’s Test and simple independent test of Mann Whitney were applied. To characterize the survival timings of the test samples, the log-rank test was used. Results: Out of the 31 abutments cyclically tested, 17 (54.8%) fractured in a number of cycles below 5 million established, and 8 (25.8%) belonged to the group of the straight abutments and 9 (29%) of the anatomical abutments, 14 samples (45.2%) resisted the cyclic (5-straight abutments and 9-anatomical abutments). According to Fisher's Exact Test showed no statistical difference between groups (p = 0.394). In relation to the load (N) submitted during the cyclic test, the straight abutments showed larger fracture loads (mean: 566N±59N) that anatomical abutments (mean: 367N±80N). In addition, the minimum and maximum load values occurring in fractured samples of the straight group were higher compared to the anatomical. Regarding the average values of bending moment (Nmm), the Mann Whitney showed variations of the moment in both groups, and the fractured samples behaved slightly significant (p = 0.09). Conclusion: In cyclic fatigue tests, the solid straight abutments obtained average load and bending moment greater than the anatomical abutments. Considering fatigue strength of the fractured samples, there was a significant difference in the load variable and bending moment, with the straight abutment showing higher mean, moreover, for the varying cycles, the two types of abutments (straight and anatomical) behaved mechanically in a similar way. / Objetivo: Analisar a resistência à fadiga dos conjuntos implante/pilar, nos tipos reto e anatômico, submetidos a cargas cíclicas. Material e métodos: Foram utilizados 37 implantes (3.75 x 11mm) com sistema cone morse e 37 pilares, divididos em dois grupos (n=16: pilar reto, n=21: pilar anatômico, Neodent® Curitiba, Paraná, Brasil). Os conjuntos foram submetidos a testes de flexão e testes cíclicos, fixando-se o número de ciclos em 5 milhões, em equipamento servo-hidráulico. Três conjuntos implante/pilar de cada grupo foram submetidos a testes de flexão para determinação da carga máxima de resistência das amostras, que serviu como medida parâmetro para os ensaios cíclicos. Foram avaliados número de ciclos, carga e momento fletor das amostras. O Teste de Fisher e teste independente simples de Mann Whitney foram aplicados. Para caracterizar os tempos de sobrevivência das amostras em ensaio, foi utilizado o Teste Log-Rank. Resultados: Dos 31 pilares testados ciclicamente, 17 (54,8%) fraturaram em um número de ciclos abaixo dos 5 milhões estabelecidos, sendo que 8 (25,8%) pertenciam ao grupo dos pilares retos e 9 (29%) dos pilares anatômicos; 14 amostras (45,2%) resistiram aos testes cíclicos (5-pilares retos (16,1%) e 9-pilares anatômicos (29,1%). De acordo com o Teste Exato de Fisher não houve diferença estatística entre os grupos (p=0,394). Em relação à carga (N) submetida durante o ensaio cíclico, os pilares retos apresentaram cargas maiores de fratura (média: 566N±59N) que os pilares anatômicos (média: 367N±80N). Além disso, os valores mínimos e máximos de carga ocorridos nas amostras fraturadas do grupo reto foram maiores em relação aos anatômicos. Quanto aos valores médios de momento fletor (Nmm), o Teste de Mann Whitney constatou variações do momento nos dois grupos, as amostras fraturadas comportaram-se de maneira ligeiramente significante (p=0,09). Conclusão: Nos ensaios cíclicos de fadiga, os pilares retos sólidos obtiveram médias de carga e de momento fletor maiores que os pilares anatômicos. Considerando resistência à fadiga das amostras fraturadas, houve diferença significante nas variáveis carga e momento fletor, com o pilar reto mostrando maiores médias; além disso, quanto à variável ciclo, os dois tipos de pilares (retos e anatômicos) comportaram-se mecanicamente de maneira semelhante.
15

"Avaliação da densidade ótica perimplantar cervical em controle longitudinal de implantes com função oclusal imediata em maxila" / Evaluation of the cervical perimplantar optical density in a longitudinal control of implants with immediate occlusion function in maxilla

Jorge Elie Hayek 11 October 2005 (has links)
A proposta neste estudo foi avaliar as alterações da densidade ótica do osso alveolar perimplantar cervical em controle longitudinal, por meio de radiografias periapicais digitalizadas de dez pacientes, nos quais foram instalados seis implantes na maxila submetidos à função oclusal imediata, mediante a instalação de uma prótese fixa 24 horas após a cirurgia. Todos os pacientes foram avaliados clinicamente, com exames da análise da freqüência de ressonância, além de controle radiográfico. Foi utilizada a técnica radiográfica intrabucal do parale lismo, com cone longo, sendo que o feixe de raios X incidiu perpendicularmente ao longo eixo do implante. Os controles radiográficos foram realizados na instalação da prótese, após 6 meses e após 12 meses. As radiografias obtidas foram então capturadas por uma câmera de vídeo (preto e branco) por meio de um microscópio ótico (40 vezes de aumento). Devido à ampliação utilizada, os implantes tiveram suas imagens digitalizadas em 2 etapas (metade direita e metade esquerda), sendo consideradas como amostras independentes. Após a sobreposição de um gabarito sobre a imagem, com a finalidade padronizar as áreas a serem estudadas, foram analisadas as densidades óticas na área de interesse osso + implante e na área de controle implante (onde não é esperada alteração) por meio do software ImageLab. Para a correção de possíveis variações na densidade da radiografia e projeção geométrica oriundas da metodologia empregada, foi utilizada uma equação matemática para validar a análise dos dados obtidos. Os resultados mostraram que ocorreu variação percentual da densidade ótica na área de interesse (osso + implante) nos primeiros seis meses (T2) com diminuição de aproximadamente 5% para o lado direito e diminuição de aproximadamente 6% para o lado esquerdo em relação às radiografias iniciais (T1) e após doze meses, a diminuição da densidade ótica estabilizou-se, não sendo encontradas alterações estatisticamente significantes em relação ao período correspondente entre T2 (seis meses) e T3 (doze meses). Os resultados da análise digital das radiografias periapicais demonstraram coincidência com os resultados da análise da freqüência de ressonância e exame clínico dos implantes e demonstraram um aspecto compatível com o sucesso dos implantes osteointegrados com função imediata na maxila. / The aim in this study was the evaluation of the variations of the perimplantar optical bone density at the cervical region in a longitudinal control, by the use of digitized radiographs of ten patients, who received six implants installed in the maxilla and submitted to immediate occlusion function, through fixed prosthesis installed 24 hours after the surgery. All the patients were observed in clinical control, with resonance frequency analysis and also radiographic control. It was performed a intraoral radiograph using the paralleling technique, with the long cone and the beam of x-ray aimed perpendicular to the long axis of the implant. The radiographic controls were done at the time of the installation of the prosthesis, after six months and after twelve months after the first control. The obtained radiographs were captured by a black and white video camera by an optical microscope (40 times of magnification). Due to the utilized magnification, the implants have their images digitized in two steps: half right and half left, and they were considered as independent samples. After the superimposition of a standardized pattern, to help the standardization of the areas of the study, it was analyzed the optical density at the areas of interest bone + implant and at areas of control bone (where it is not hope changes) through the software ImageLab. To correct possible variations of the effect of the absence of standardization of the geometric projection and the radiographic density, it was realized a mathematic equation and it was obtained a correction factor of density in order to compensate. The results sho wed that there were percentage variation of the optical density at the area of interest (bone + implant) at six months (T2) showed a decreased of about 5% for the right side and showed a decreased of about 6% for the left side when analyzed the first control and after twelve months no significant statistical difference was observed between the T2 period (six months) and T3 period (twelve months). The results of digital analysis from the intraoral radiographs showed as the same as the results of resonance frequency analysis and the clinic examination of the implants and showed a success of implants installed in the maxilla with immediate occlusion function.
16

Estudo de dois sistemas de reabilitação com implantes submetidos à ativação imediata: análise clínica, radiográfica e da estabilidade, por frequência de ressonância / Study of two rehabilitation systems with dental implants submitted to immediate loading: clinical and radiographic evaluations, and stability using resonance frequency analysis

Eduardo Antonio Ayub 28 August 2007 (has links)
Avaliou-se o comportamento biomecânico, quanto à área de estabilidade protética, extensão de cantilever e estabilidade por análise freqüência de ressonância (AFR); parâmetros clínicos: índice de placa (IP), índice de sangramento (IS), supuração, distância da plataforma do implante-margem da mucosa (DPM), profundidade de sondagem (PS), nível de inserção (NI), sangramento à sondagem (SS), largura (LM), espessura (EM) da mucosa e análise radiográfica, em dois sistemas de reabilitações implanto-suportadas. Foram instalados 104 implantes, submetidos à ativação imediata, em 26 pacientes, divididos em dois grupos: A (n= 16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). As próteses foram instaladas em tempo médio de 32h. (T0), e controles realizados em seis (T6), doze (T12) e 24 meses (T24). Como resultado, a taxa de sucesso foi de 100% para o grupo A e 90% para o grupo B para implantes e próteses. Diferenças significantes (p<0,05) foram apresentadas entre o cantilever posterior 10,96mm e 18,81mm e o braço de resistência (BR) 13,87mm e 5,50mm, respectivamente para os grupos A e B. A área de estabilidade, no grupo A foi de 373,5mm2 e no B de 112,8mm2; a média da AFR (em ISQ) do grupo A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 e do grupo B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, com diferenças (p<0,05) entre os tempos (grupo A) e posição dos implantes (grupo B). O IP no grupo A=1,0 e 0,7; grupo B=0,6 e 0,9, o IS (0,7), supuração (ausente) e SS (presença) no grupo A=50% e 37,9%; grupo B=70,1 e 52,1%, no controle de 12 e 24 meses, não mostraram diferenças estatísticas entre os grupos. As médias (em mm) da LM para o grupo A (2,05 e 2,21) e B (2,29 e 2,40) e EM grupo A (1,53 e 1,56) e B (1,31 e 1,43), DPM do grupo A (2,54e 2,52) e B (0,18mm e -0,12mm), PS grupo A (3,52 e 3,52) e B (3,52 e 4,0), NI grupo A (0,98 e 0,99) e B (3,05 e 3,57) e perda óssea grupo A (0,45mm e 0,23mm ) grupo B(0,66mm e 0,22mm), respectivamente para 12 e 24 meses, apresentaram diferenças estatísticas entre os controles. Concluindo-se que 1- O grupo A apresentou área de estabilidade e extensão de cantilever anterior e posterior, com comportamento biomecânico mais favorável do que no grupo B; 2- A estabilidade primária e secundária (AFR) foi diferente entre os tempos (grupo A) e posição dos implantes (grupo B), mas semelhantes entre os grupos; 3- Os parâmetros clínicos de índice de placa, sangramento marginal, supuração, profundidade de sondagem (exceto para os períodos de controle no grupo B), sangramento a sondagem, largura e espessura de mucosa ceratinizada foram semelhantes entre os grupos; 4- A distância da plataforma do implante-margem da mucosa foi maior no grupo A e o nível de inserção foi maior no grupo B; 5- A perda na altura da crista óssea foi semelhante entre os grupos; 6- A perda óssea foi menor nos implantes anteriores do que nos posteriores, nos grupos. / Two implant-supported rehabilitation systems were evaluated considering their biomechanical behavior, the area of prosthetic stability, cantilever extensions, stability using resonance frequency analysis (RFA) and clinical parameters, such as: modified plaque index (PI), modified bleeding index (BI), suppuration, distance between the implant shoulder and the mucosal margin (DIM), probing pocket depth (PD), probing attachment level (PAL), bleeding on probing (BP), thickness (TM) width (WM) of keratinized mucosa and radiographic analysis. One hundred and four implants had been installed in twenty six patients, submitted to immediate loading and divided into two groups: A (n=16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). The prosthesis had been installed in average time of 32h (T0), and controls made in (T6), 12 (T12) and 24 months (T24). As result, the success rate was 100% for the group A and 90% for the group B for both implants and prosthesis. Significant differences (p<0,05) 10,96mm and 18,81mm had been presented between posterior cantilever and the resistance arm (RA) 13,87mm and 5,50mm, respectively for the groups A and B. The stability area, in the group A was of 373,5mm2 and in B of 112,8mm2; the average of RFA (in ISQ) of the group A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 and of the group B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, with differences (p<0,05) between the periods (Group A) and implant position (Group B). The PI in group A was of 1,0 and 0,7 and 0,6 and 0,9 for group B, o BI (0,7), suppuration (absent), DP (presence) in group A=50% and 37,9%; group B=70,1 and 52,1%, in the control of 12 and 24 months, did not present statistical differences between the groups. The average (in mm) of WM for the group A (2,05 and 2,21) and B (2,29 and 2,40) and TM group A (1,53 and 1,56) and B (1,31 and 1,43), DIM of group A (2,54 and 2,52) and B (0,18mm and -0,12mm), DP group.
17

Efeito de diferentes tempos de ativação sobre a estabilidade e resposta óssea ao redor de implantes dentários. Estudo por análise de freqüência de ressonância e histomorfométrico em cães / Effect of different loading time on the stabililty and boné response around dental implants. Resonance frequency analysis and histomorphometric study in dogs.

Jayme, Sérgio Jorge 16 April 2009 (has links)
Propósito: O objetivo deste estudo foi avaliar a estabilidade primária com análise de freqüência de ressonância e a resposta óssea por histomorfometria em implantes sob tratamento com carga imediata e carga precoce. Material e método: Foram colocados três implantes Replace Select (Nobel Biocare, Suécia) em cada lado da mandíbula de 8 cães, totalizando 48 implantes no estudo. Um par de implantes foi selecionado para o protocolo de carga imediata (CI). Após sete dias, o segundo par de implantes recebeu as próteses para o protocolo de carga precoce (CP). Catorze dias após a colocação dos implantes, o terceiro par de implantes recebeu as próteses para o protocolo de carga precoce tardia (CPT). Em cada período foi medida a estabilidade dos implantes por freqüência de ressonância. Após o período total de doze semanas da colocação das próteses os animais foram sacrificados e os espécimes foram preparados para análise histomorfométrica. As diferenças entre os tempos de carregamento para os seguintes parâmetros: estabilidade, contato ossoimplante (COI), densidade óssea (DO) e perda da crista óssea (PCO) foram avaliadas usando ANOVA. Resultados: Os valores iniciais de estabilidade (ISQ) dos implantes foram: 77,88 ± 4,61 para CI, 79,73 ± 3,55 para CP e 79,64 ± 3,00 para CPT, sem diferença estatisticamente significante (p=0,30). Os valores finais de estabilidade foram 80,46 ± 4,23 para CI, 81,88 ± 3,55 para CP e 81,88 ± 3,42 para CPT, também sem diferença estatística (p=0,47). Para avaliar a estabilidade dos implantes em função do tempo, foi realizada ANOVA para amostras repetidas e para cada grupo foi detectado aumento significativo da estabilidade ao final do experimento (p=0,003). A interação método de carregamento versus tempo não foi significativa (p=0,97). A porcentagem de COI para CI foi 77,9 ± 1,71%, para CP foi 79,25 ± 2,11% e para CPT foi 79,42 ± 1,49%. A porcentagem de DO para CI foi 69,97 ± 3,81%, para CP foi 69,23 ± 5,68% e para CPT foi 69,19 ± 2,90%. A PCO para CI foi 1,57 ± 0,22 mm, para CP foi 1,23 ± 0,19 mm e para CPT foi 1,17 ± 0,32 mm. Não foi observada diferença estatística para nenhum dos parâmetros avaliados (p>0,05). Conclusão: Considerando a estabilidade primária, contato osso-implante, densidade óssea ao redor do implante e perda da crista óssea em cães, conclui-se que não existem diferenças estatisticamente significantes num prazo de até 12 semanas para implantes submetidos à ativação imediata, em 7 dias ou 14 dias após a cirurgia. / Purpose: The aim of this study was to evaluate the implant stability through frequency resonance analysis and the effect that different loading time will have on the bone response around implants through a histomorphometric analysis. Material and Methods: Three Replace Select implants were placed on each side of the mandible in 8 dogs totaling 48 implants in the study. One pair of implants was selected for immediate loading protocol (IL). After seven days the second pair of implants received the prostheses for the early loading protocol (EL). In each period, the implant stability measurements were performed by means of resonance frequency. After 12 weeks, a new reading of the implant stability was performed. Fourteen days after the implant placement the third pair of implants received the prostheses for the advanced early loading (AEL). Following a period totaling twelve weeks of prosthetics, the animals were sacrificed and the specimens were prepared for histomorphometric analysis. The differences between loading time in the following parameters: bone-to-implant contact (BIC), bone density (BD) and crestal bone loss (CBL) were evaluated through ANOVA. Results: The mean values of initial stability (ISQ) in different loading times were 77.88 ± 4.61 (IL), 79.73 ± 3.55 (EL) and 79.64 ± 3.00 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.30). The mean values of final stability in different loading times were 80.46 ± 4.23 (IL), 81.88 ± 3.55 (EL) and 81.88 ± 3.42 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.47). To evaluate the implant stability in function of time, a variance analysis for repeated samples was performed, and there was significant difference (p = 0.003), indicating, for each group, a significant increase in stability at the end of the experiment. The time versus method interaction did not show significant difference (p = 0.97), indicating that the variations are similar in the studied groups. The percentage of BIC for IL was 77.9 ± 1.71%, for EL was 79.25 ± 2.11% and for AEL was 79.42 ± 1.49%. The percentage of BD for IL was 69.97 ± 3.81%, for EL was 69.23 ± 5.68% and for AEL was 69.19 ± 2.90%. The CBL for IL was 1.57 ± 0.22mm, for EL was 1.23 ± 0.19mm and for AEL was 1.17 ± 0.32mm. There was no statistical difference for any of the parameters evaluated (p>0.05). Conclusion: Considering primary stability, bone-to-implant contact, bone density around the implants and crestal bone loss, there are no significant differences until 12 weeks after surgery for the stability of immediate, 7 or 14 days after placement activated implants.
18

Efeito de diferentes tempos de ativação sobre a estabilidade e resposta óssea ao redor de implantes dentários. Estudo por análise de freqüência de ressonância e histomorfométrico em cães / Effect of different loading time on the stabililty and boné response around dental implants. Resonance frequency analysis and histomorphometric study in dogs.

Sérgio Jorge Jayme 16 April 2009 (has links)
Propósito: O objetivo deste estudo foi avaliar a estabilidade primária com análise de freqüência de ressonância e a resposta óssea por histomorfometria em implantes sob tratamento com carga imediata e carga precoce. Material e método: Foram colocados três implantes Replace Select (Nobel Biocare, Suécia) em cada lado da mandíbula de 8 cães, totalizando 48 implantes no estudo. Um par de implantes foi selecionado para o protocolo de carga imediata (CI). Após sete dias, o segundo par de implantes recebeu as próteses para o protocolo de carga precoce (CP). Catorze dias após a colocação dos implantes, o terceiro par de implantes recebeu as próteses para o protocolo de carga precoce tardia (CPT). Em cada período foi medida a estabilidade dos implantes por freqüência de ressonância. Após o período total de doze semanas da colocação das próteses os animais foram sacrificados e os espécimes foram preparados para análise histomorfométrica. As diferenças entre os tempos de carregamento para os seguintes parâmetros: estabilidade, contato ossoimplante (COI), densidade óssea (DO) e perda da crista óssea (PCO) foram avaliadas usando ANOVA. Resultados: Os valores iniciais de estabilidade (ISQ) dos implantes foram: 77,88 ± 4,61 para CI, 79,73 ± 3,55 para CP e 79,64 ± 3,00 para CPT, sem diferença estatisticamente significante (p=0,30). Os valores finais de estabilidade foram 80,46 ± 4,23 para CI, 81,88 ± 3,55 para CP e 81,88 ± 3,42 para CPT, também sem diferença estatística (p=0,47). Para avaliar a estabilidade dos implantes em função do tempo, foi realizada ANOVA para amostras repetidas e para cada grupo foi detectado aumento significativo da estabilidade ao final do experimento (p=0,003). A interação método de carregamento versus tempo não foi significativa (p=0,97). A porcentagem de COI para CI foi 77,9 ± 1,71%, para CP foi 79,25 ± 2,11% e para CPT foi 79,42 ± 1,49%. A porcentagem de DO para CI foi 69,97 ± 3,81%, para CP foi 69,23 ± 5,68% e para CPT foi 69,19 ± 2,90%. A PCO para CI foi 1,57 ± 0,22 mm, para CP foi 1,23 ± 0,19 mm e para CPT foi 1,17 ± 0,32 mm. Não foi observada diferença estatística para nenhum dos parâmetros avaliados (p>0,05). Conclusão: Considerando a estabilidade primária, contato osso-implante, densidade óssea ao redor do implante e perda da crista óssea em cães, conclui-se que não existem diferenças estatisticamente significantes num prazo de até 12 semanas para implantes submetidos à ativação imediata, em 7 dias ou 14 dias após a cirurgia. / Purpose: The aim of this study was to evaluate the implant stability through frequency resonance analysis and the effect that different loading time will have on the bone response around implants through a histomorphometric analysis. Material and Methods: Three Replace Select implants were placed on each side of the mandible in 8 dogs totaling 48 implants in the study. One pair of implants was selected for immediate loading protocol (IL). After seven days the second pair of implants received the prostheses for the early loading protocol (EL). In each period, the implant stability measurements were performed by means of resonance frequency. After 12 weeks, a new reading of the implant stability was performed. Fourteen days after the implant placement the third pair of implants received the prostheses for the advanced early loading (AEL). Following a period totaling twelve weeks of prosthetics, the animals were sacrificed and the specimens were prepared for histomorphometric analysis. The differences between loading time in the following parameters: bone-to-implant contact (BIC), bone density (BD) and crestal bone loss (CBL) were evaluated through ANOVA. Results: The mean values of initial stability (ISQ) in different loading times were 77.88 ± 4.61 (IL), 79.73 ± 3.55 (EL) and 79.64 ± 3.00 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.30). The mean values of final stability in different loading times were 80.46 ± 4.23 (IL), 81.88 ± 3.55 (EL) and 81.88 ± 3.42 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.47). To evaluate the implant stability in function of time, a variance analysis for repeated samples was performed, and there was significant difference (p = 0.003), indicating, for each group, a significant increase in stability at the end of the experiment. The time versus method interaction did not show significant difference (p = 0.97), indicating that the variations are similar in the studied groups. The percentage of BIC for IL was 77.9 ± 1.71%, for EL was 79.25 ± 2.11% and for AEL was 79.42 ± 1.49%. The percentage of BD for IL was 69.97 ± 3.81%, for EL was 69.23 ± 5.68% and for AEL was 69.19 ± 2.90%. The CBL for IL was 1.57 ± 0.22mm, for EL was 1.23 ± 0.19mm and for AEL was 1.17 ± 0.32mm. There was no statistical difference for any of the parameters evaluated (p>0.05). Conclusion: Considering primary stability, bone-to-implant contact, bone density around the implants and crestal bone loss, there are no significant differences until 12 weeks after surgery for the stability of immediate, 7 or 14 days after placement activated implants.

Page generated in 0.0707 seconds