• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e aplicações de eletrodos de ouro confeccionados a partir de discos compactos graváveis (CD-Rs) / Development and applications of gold electrodes confectioned from recordable compact disc (CD-RS)

Richter, Eduardo Mathias 22 January 2001 (has links)
O presente trabalho descreve uma forma inédita e simples de construção de eletrodos de ouro (CDtrodos) a partir de discos compactos graváveis (CD-Rs). Os CD-Rs possuem em sua constituição uma película de ouro com uma espessura entre 50 e 100 nm e com área aproximada de 100 cm2. Esta superfície de ouro pode ser facilmente utilizada para construção de eletrodos convencionais usados em células estacionárias ou em células em fluxo. Além disso, a espessura nanométrica do filme de ouro também pode ser utilizada para construção de microeletrodos de banda com áreas inferiores a 10-6 cm2. Devido ao fato do CD-R ser produzido em escala comercial, o custo do mesmo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Para comprovar a viabilidade da utilização destes filmes na confecção de eletrodos, seu desempenho foi comparado com o de eletrodo de ouro comercial, sendo observado um comportamento análogo. Diferentes maneiras de utilização do disco compacto gravável foram testadas, tanto em amostras sintéticas, como também, em amostras reais. Utilizando o método de redissolução potenciométrica à corrente constante (CCPSA), foram analisadas amostras de mercúrio em água potável e em água do mar, adaptando o CD-R a uma célula de injeção em fluxo. Nestes estudos, o limite de detecção de mercúrio situou-se em 250 ng L-1, utilizando-se tempo de deposição de 300 segundos. Estudos preliminares em células estacionárias levaram a limites de detecção inferiores. Em célula estacionária, foram realizadas análises de cobre em aguardente e em água potável. Em alguns casos, os resultados obtidos com as amostras reais foram comparados com outra técnica (E.A.A.), onde os resultados obtidos foram muito próximos a àqueles obtidos com os eletrodos de ouro. Análises em água de abastecimento, mostraram que em células estacionárias o limite de detecção para cobre situa-se em 30 ng L-1, para tempos de deposição de 600 segundos. / This work describes an original and novel form of construction of gold electrodes (CDtrodes) from recordable CDs (CD-Rs). The CD-Rs contain in its constitution a fine gold layer with a thickness from 50 to 100 nm and an approx. 100 cm2 of area. This surface can be easily used for construction of conventional electrodes for stationary or flow electrochemical cells. Moreover, the nanometer thickness of the gold film can be employed for the construction of microelectrodes with areas smaller than 10-6 cm2. Due to the fact that CD-Rs are produced on commercial scale, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. To prove the suitability of these films to make gold electrodes, their performance was compared with the response of a commercial electrode, and a similar behavior was observed. Different applications of recordable compact disk were tested either with synthetic or real samples. Using the Constant-Current Potentiometric Stripping Analysis (CCPSA) method, mercury was analyzed in seawater and drinking water samples, fitting the CD-R to flow injection analysis cell. In these studies, the detection limit for mercury was found to be 250 ng L-1, with a deposition time of 300 seconds. Preliminary studies involving stationary cells allowed lower detection limits for mercury to be attained. With a stationary cell, the analyses of copper in sugar cane spirits and drinking water were carried out. In some instances, comparisons were made between this and another analytical technique (namely A.A.S.) where the results were very close with the ones obtained with the gold electrodes. Analysis of drinking water showed that for stationary cells the detection limit for copper is 30 ng L-1, with a deposition time of 600 s.
2

\"Desenvolvimento de novos sensores a partir de CD-Rs para análise voltametrica e de métodos de eletroforese capilar para monitoramento de íons em águas\" / Development of new sensors from compact disc for voltammetric analysis and electrophoresis methods for monitoring of ions in water

Richter, Eduardo Mathias 10 December 2004 (has links)
Neste trabalho descreve-se o desenvolvimento de metodologias para análise de metais pesados em águas de abastecimento (sistema Guarapiranga) e em água de chuva por métodos voltamétricos, a quantificação de cátions e ânions por eletroforese capilar com detecção condutométrica sem contato (EC-DCC), a construção de eletrodos de prata a partir de CD-Rs e sua aplicação para medidas potenciométricas, amperométricas e voltamétricas, a confecção de microeletrodos de ouro explorando técnicas de micro-fabricação com toner e sua aplicação como detector amperométrico em eletroforese capilar e o uso de máscaras de toner para construção de redes de microeletrodos de ouro, platina e carbono. Para o desenvolvimento de metodologia para monitorar chumbo, cobre e mercúrio em águas de abastecimento e em água de chuva, enfatizou-se a utilização de dispositivos semidescartáveis de ouro construídos a partir de CD-Rs utilizando técnicas eletroanalíticas de redissolução. O limite de detecção para 300 s de pré-concentração foi calculado em 80, 90 e 100 ng L-1 para Pb2+, Cu2+ e Hg2+, respectivamente. O volume mínimo de amostra necessário para esta análise é de 0,5 mL. Para analisar estes metais em amostras de águas coletadas do sistema Guarapiranga, foi implementado um método alternativo simples e de baixo custo para eliminação da matéria orgânica presente nestas amostras. Este método permite o pré-tratamento de um grande número de amostras simultaneamente. Em adição à quantificação de metais pesados, ao longo deste trabalho também foi otimizada uma metodologia para o monitoramento de vários outros íons (Cl-, NO3-, SO42-, CH3COO-, F-, PO43-, NH4+, K+, Na+, Ca2+, Mg2+ e Li+) em águas do sistema Guarapiranga utilizando equipamento de eletroforese capilar com detecção condutométrica sem contato (EC-DCC) construído no laboratório. O limite de detecção para estes íons foi calculado em 0,23, 0,43, 0,50, 4,26, 0,75, 1,00, 0,09, 0,18, 0,19, 0,20, 0,19 e 0,23 mg L-1, respectivamente. Além da utilização de eletrodos de ouro, ao longo desta tese também foi desenvolvida metodologia para a construção de sensores a partir de CD-Rs de prata. São discutidas as diferentes etapas envolvidas na elaboração destes dispositivos, é apresentada a sua caracterização e são mostrados os resultados obtidos por voltametria de redissolução para análise de chumbo, por amperometria/FIA para análise de cianeto e por potenciometria/FIA para análise de cloreto. A aplicação de técnicas de micro-fabricação com toner para desenvolver detectores amperométricos de ouro para eletroforese capilar foi outro assunto estudado. Estes sensores foram acoplados a um sistema de eletroforese capilar utilizando uma célula do tipo \"wall-jet\". A potencialidade deste tipo de detecção em eletroforese capilar foi demonstrada com a análise simultânea de iodeto, ácido ascórbico, dipirona e paracetamol. O limite de detecção para estes íons foi calculado em 0,1, 0,5, 3,1 e 1,1 µmol L-1, respectivamente. O uso de máscaras de toner para construir redes de microeletrodos de ouro, platina e carbono é outro tópico apresentado nesta tese. Informações detalhadas sobre as etapas e parâmetros envolvidos na construção deste tipo de sensor são apresentadas. O desempenho, assim como algumas características peculiares destes dispositivos são demonstradas através do uso de sistemas químicos conhecidos e os resultados obtidos comparados com os de um eletrodo convencional. / This study describe the development of methodologies for the analysis of heavy metals in drinking water supply (Guarapiranga system) and in rain water by using voltammetric methods, for the quantification of cations and anions by capillary electrophoresis using contactless conductometric detection (CE-CCD), the construction of silver electrodes utilizing recordable CDs and its application for potentiometric, amperometric and voltammetric analysis, the confection of microelectrodes utilizing microfabrication techniques with toner and its application as electrochemical detector in capillary electrophoresis and the utilization of toner masks to construct gold, platinum and carbon microelectrodes arrays. In the development of methodologies for lead, copper and mercury monitoring for natural waters and in rain water, was emphasized the utilization of semi-disposable gold electrodes constructed from recordable CDs, utilizing stripping analysis techniques. The detection limit utilizing 300 s pre-concentration time was calculated as 80, 90 and 100 ng L-1 for Pb2+, Cu2+ e Hg2+, respectively. The minimum sample volume for each analysis is 0.5 mL. For the analysis of these metals in waters samples collected in the Guarapiranga dam, a simple and alternative low cost method to eliminate the organic mater present in these samples was implemented. This method permits the pre-treatment of many samples simultaneously. In addition to the quantification of heavy metals, in the course of this work, the methodology for monitoring many other ions (Cl-, NO3-, SO42-, CH3COO-, F-, PO43-, NH4+, K+, Na+, Ca2+, Mg2+ e Li+) in the waters from Guarapiranga dam utilizing capillary electrophoresis with contactless conductometric detection (CE-CCD), an instrument constructed in the laboratory was also optimized. The detection limit for these ions was calculated as 0.23, 0.43, 0.50, 4.26, 0.75, 1.00, 0.09, 0.18, 0.19, 0.20, 0.19 e 0.23 mg L-1, respectively. Apart from the utilization of gold electrodes, on this work, we also developed a new methodology for the construction of sensors starting from silver CD-Rs. The different steps involved in the manufacture of these devices are discussed, its characterization is presented and the results obtained utilizing voltammetry for lead analysis, FIA/amperometry for the analysis of cyanide and FIA/potentiometry for the analysis of chloride. The utilization of microfabrication techniques with toner to develop amperometric gold detectors for capillary electrophoresis applications was another subject investigated. These sensors were coupled a capillary electrophoresis system using a wall-jet type cell. The potentiality of this type of detection for capillary electrophoresis was demonstrated for the simultaneous analysis of iodide, ascorbic acid, dipyrone and paracetamol. The detection limit for these ions was calculated as 0.1, 0.5, 3.1 and 1.1 µmol L-1, respectively. The utilization of masks made with toner to construct arrays of gold, platinum and carbon microelectrodes is another topic presented in this thesis. Detailed information about the steps and factors involved in the construction of this kind of sensor are presented. The performance as well as some peculiar characteristics of these devices are demonstrated utilizing well know chemical systems and the results obtained compared to the ones of a conventional electrode.
3

\"Desenvolvimento de novos sensores a partir de CD-Rs para análise voltametrica e de métodos de eletroforese capilar para monitoramento de íons em águas\" / Development of new sensors from compact disc for voltammetric analysis and electrophoresis methods for monitoring of ions in water

Eduardo Mathias Richter 10 December 2004 (has links)
Neste trabalho descreve-se o desenvolvimento de metodologias para análise de metais pesados em águas de abastecimento (sistema Guarapiranga) e em água de chuva por métodos voltamétricos, a quantificação de cátions e ânions por eletroforese capilar com detecção condutométrica sem contato (EC-DCC), a construção de eletrodos de prata a partir de CD-Rs e sua aplicação para medidas potenciométricas, amperométricas e voltamétricas, a confecção de microeletrodos de ouro explorando técnicas de micro-fabricação com toner e sua aplicação como detector amperométrico em eletroforese capilar e o uso de máscaras de toner para construção de redes de microeletrodos de ouro, platina e carbono. Para o desenvolvimento de metodologia para monitorar chumbo, cobre e mercúrio em águas de abastecimento e em água de chuva, enfatizou-se a utilização de dispositivos semidescartáveis de ouro construídos a partir de CD-Rs utilizando técnicas eletroanalíticas de redissolução. O limite de detecção para 300 s de pré-concentração foi calculado em 80, 90 e 100 ng L-1 para Pb2+, Cu2+ e Hg2+, respectivamente. O volume mínimo de amostra necessário para esta análise é de 0,5 mL. Para analisar estes metais em amostras de águas coletadas do sistema Guarapiranga, foi implementado um método alternativo simples e de baixo custo para eliminação da matéria orgânica presente nestas amostras. Este método permite o pré-tratamento de um grande número de amostras simultaneamente. Em adição à quantificação de metais pesados, ao longo deste trabalho também foi otimizada uma metodologia para o monitoramento de vários outros íons (Cl-, NO3-, SO42-, CH3COO-, F-, PO43-, NH4+, K+, Na+, Ca2+, Mg2+ e Li+) em águas do sistema Guarapiranga utilizando equipamento de eletroforese capilar com detecção condutométrica sem contato (EC-DCC) construído no laboratório. O limite de detecção para estes íons foi calculado em 0,23, 0,43, 0,50, 4,26, 0,75, 1,00, 0,09, 0,18, 0,19, 0,20, 0,19 e 0,23 mg L-1, respectivamente. Além da utilização de eletrodos de ouro, ao longo desta tese também foi desenvolvida metodologia para a construção de sensores a partir de CD-Rs de prata. São discutidas as diferentes etapas envolvidas na elaboração destes dispositivos, é apresentada a sua caracterização e são mostrados os resultados obtidos por voltametria de redissolução para análise de chumbo, por amperometria/FIA para análise de cianeto e por potenciometria/FIA para análise de cloreto. A aplicação de técnicas de micro-fabricação com toner para desenvolver detectores amperométricos de ouro para eletroforese capilar foi outro assunto estudado. Estes sensores foram acoplados a um sistema de eletroforese capilar utilizando uma célula do tipo \"wall-jet\". A potencialidade deste tipo de detecção em eletroforese capilar foi demonstrada com a análise simultânea de iodeto, ácido ascórbico, dipirona e paracetamol. O limite de detecção para estes íons foi calculado em 0,1, 0,5, 3,1 e 1,1 µmol L-1, respectivamente. O uso de máscaras de toner para construir redes de microeletrodos de ouro, platina e carbono é outro tópico apresentado nesta tese. Informações detalhadas sobre as etapas e parâmetros envolvidos na construção deste tipo de sensor são apresentadas. O desempenho, assim como algumas características peculiares destes dispositivos são demonstradas através do uso de sistemas químicos conhecidos e os resultados obtidos comparados com os de um eletrodo convencional. / This study describe the development of methodologies for the analysis of heavy metals in drinking water supply (Guarapiranga system) and in rain water by using voltammetric methods, for the quantification of cations and anions by capillary electrophoresis using contactless conductometric detection (CE-CCD), the construction of silver electrodes utilizing recordable CDs and its application for potentiometric, amperometric and voltammetric analysis, the confection of microelectrodes utilizing microfabrication techniques with toner and its application as electrochemical detector in capillary electrophoresis and the utilization of toner masks to construct gold, platinum and carbon microelectrodes arrays. In the development of methodologies for lead, copper and mercury monitoring for natural waters and in rain water, was emphasized the utilization of semi-disposable gold electrodes constructed from recordable CDs, utilizing stripping analysis techniques. The detection limit utilizing 300 s pre-concentration time was calculated as 80, 90 and 100 ng L-1 for Pb2+, Cu2+ e Hg2+, respectively. The minimum sample volume for each analysis is 0.5 mL. For the analysis of these metals in waters samples collected in the Guarapiranga dam, a simple and alternative low cost method to eliminate the organic mater present in these samples was implemented. This method permits the pre-treatment of many samples simultaneously. In addition to the quantification of heavy metals, in the course of this work, the methodology for monitoring many other ions (Cl-, NO3-, SO42-, CH3COO-, F-, PO43-, NH4+, K+, Na+, Ca2+, Mg2+ e Li+) in the waters from Guarapiranga dam utilizing capillary electrophoresis with contactless conductometric detection (CE-CCD), an instrument constructed in the laboratory was also optimized. The detection limit for these ions was calculated as 0.23, 0.43, 0.50, 4.26, 0.75, 1.00, 0.09, 0.18, 0.19, 0.20, 0.19 e 0.23 mg L-1, respectively. Apart from the utilization of gold electrodes, on this work, we also developed a new methodology for the construction of sensors starting from silver CD-Rs. The different steps involved in the manufacture of these devices are discussed, its characterization is presented and the results obtained utilizing voltammetry for lead analysis, FIA/amperometry for the analysis of cyanide and FIA/potentiometry for the analysis of chloride. The utilization of microfabrication techniques with toner to develop amperometric gold detectors for capillary electrophoresis applications was another subject investigated. These sensors were coupled a capillary electrophoresis system using a wall-jet type cell. The potentiality of this type of detection for capillary electrophoresis was demonstrated for the simultaneous analysis of iodide, ascorbic acid, dipyrone and paracetamol. The detection limit for these ions was calculated as 0.1, 0.5, 3.1 and 1.1 µmol L-1, respectively. The utilization of masks made with toner to construct arrays of gold, platinum and carbon microelectrodes is another topic presented in this thesis. Detailed information about the steps and factors involved in the construction of this kind of sensor are presented. The performance as well as some peculiar characteristics of these devices are demonstrated utilizing well know chemical systems and the results obtained compared to the ones of a conventional electrode.
4

Desenvolvimento de sensores eletroanalíticos utilizando eletrodos modificados com filme de Bismuto / Development of electroanalytical sensors utilizing modified electrodes with Bismuth Film

Fernando Castro Mota de Oliveira 15 August 2008 (has links)
A utilização de eletrodos modificados com filmes de Bismuto, formados in situ, é um método prático para a determinação de metais através da pré-concentração e redissolução anódica, pois a modificação do eletrodo e a pré-concentração dos analitos são realizadas simultaneamente. O processo de fabricação de eletrodos de Au através de CD-Rs é uma alternativa barata para a confecção de eletrodos descartáveis, pois devido ao baixo custo e facilidade, com um único CD-R é possível produzir de um grande número de eletrodos possibilitando a realização de várias medições. Quando não mais apresentar o comportamento desejado, o sensor simplesmente é descartado. Tal processo é vantajoso no sentido de que após a realização da redissolução dos metais préconcentrados no eletrodo, o mesmo pode não apresentar o perfil anterior devido a uma quantidade residual de bismuto do filme remanescente no eletrodo. Devido a facilidade de produção de eletrodos de CD-R foram construídos sistemas integrados contendo os três eletrodos necessário para a célula eletroquímica através da técnica de corrosão com iodo/iodeto. Tal processo foi realizado fazendo-se a proteção das áreas dos eletrodos com toner de impressora, transferido termicamente. Após a corrosão, o toner é retirado com algodão embebido em acetonitrila. Um eletrodo de (pseudo) referência (Ag/AgCl KCl 0,1 mol L-1) foi incorporado ao sistema através da eletrodeposição de Ag sobre um dos três eletrodos de Au e posterior reoxidação de uma porção da Ag eletrodepositada em meio contendo íons cloreto para a formação de AgCl. Tal sistema apresentou uma boa repetibilidade de medidas de voltametria de onda quadrada realizadas após a pré-concentração sobre filmes de Bi formado in situ em soluções de Pb e Cd a uma concentração de 2,0x10-6 mol L-1. A concentração de Bi3+ utilizado para a formação do filme foi de 1,0x10-4 mol L-1. O estudo da concentração dos íons Bi3+ utilizado para a formação do filme mostrou-se um parâmetro que afeta crucialmente o formato das curvas analíticas para ambos os metais Cd e Pb, apresentando variações na sensibilidade do método para ambos os metais e dificultando a determinação conjunta dos mesmos para concentrações mais baixas. A quantificação destes metais foi realizada em amostras de urina e de combustíveis como óleo Diesel e Biodiesel através do método de adição de padrões, os quais se apresentaram em faixas a nível de traços (µg.L-1). / The use of in situ Bismuth film modified electrodes is a practice method for the determination of metals by a preconcentration and anodic stripping, because the modification of electrode and preconcentration of analites in made simultaneously. The Au electrode manufacturing by CD-Rs is a cheap alternative method to build disposable electrodes, due the low cost and easily, with a unique CD-R is possible the production of a great number of electrodes whose possibility the realization of many measurements. When the preview behavior is anymore observed, the sensor is just discarded. This process is advantageous in the sense of after the stripping step, in which the pre-concentrated metals is getting out the electrode, the same cannot represent itself as the beginning profile, due a residual quantity of bismuth in the film remainder in the electrode. Because the easily of production of CD-R electrodes were made array of Au electrodes containing three electrodes, necessarily to electrochemistry cell, by the etching technique with iodide/iodine. This process was made using the protection of electrodes area with laser printer ink, by the thermal transference. After the etching, the toner ink is removed with swab cotton, absorbed in acetonitrile. A pseudo reference electrode (Ag/AgCl KCl 0,1 mol L-1) was incorporated to the system by electrodepositing of a Ag film on one of the three Au electrodes and following the reoxidation of a portion of Ag in a medium containing clorine ions to the formation of Ag/AgCl. The system show a good repeatability of square-wave voltammetry measures carry out through the preconcentration on Bi film formed in situ of Pb and Cd in a concentration of 2,0x10-6 mol L-1. The concentration of Bi3+ utilized to formation of in situ film was 1x10-4 mol L-1. The study of Bi3+ ions concentration shows that the same is an important parameter who affects crucially the format of analytical curves for both metals Cd e Pb, presenting variations in the sensibility of method for both metals and difficulting the simultaneous determination of these metals for lower concentrations. The quantification of theses metals was realized in urine and fuel oils, as Diesel oil and Biodiesel samples by the standard-addition method, whose was found in traces level concentration (&#181g L-1)
5

Desenvolvimento de sensores eletroanalíticos utilizando eletrodos modificados com filme de Bismuto / Development of electroanalytical sensors utilizing modified electrodes with Bismuth Film

Oliveira, Fernando Castro Mota de 15 August 2008 (has links)
A utilização de eletrodos modificados com filmes de Bismuto, formados in situ, é um método prático para a determinação de metais através da pré-concentração e redissolução anódica, pois a modificação do eletrodo e a pré-concentração dos analitos são realizadas simultaneamente. O processo de fabricação de eletrodos de Au através de CD-Rs é uma alternativa barata para a confecção de eletrodos descartáveis, pois devido ao baixo custo e facilidade, com um único CD-R é possível produzir de um grande número de eletrodos possibilitando a realização de várias medições. Quando não mais apresentar o comportamento desejado, o sensor simplesmente é descartado. Tal processo é vantajoso no sentido de que após a realização da redissolução dos metais préconcentrados no eletrodo, o mesmo pode não apresentar o perfil anterior devido a uma quantidade residual de bismuto do filme remanescente no eletrodo. Devido a facilidade de produção de eletrodos de CD-R foram construídos sistemas integrados contendo os três eletrodos necessário para a célula eletroquímica através da técnica de corrosão com iodo/iodeto. Tal processo foi realizado fazendo-se a proteção das áreas dos eletrodos com toner de impressora, transferido termicamente. Após a corrosão, o toner é retirado com algodão embebido em acetonitrila. Um eletrodo de (pseudo) referência (Ag/AgCl KCl 0,1 mol L-1) foi incorporado ao sistema através da eletrodeposição de Ag sobre um dos três eletrodos de Au e posterior reoxidação de uma porção da Ag eletrodepositada em meio contendo íons cloreto para a formação de AgCl. Tal sistema apresentou uma boa repetibilidade de medidas de voltametria de onda quadrada realizadas após a pré-concentração sobre filmes de Bi formado in situ em soluções de Pb e Cd a uma concentração de 2,0x10-6 mol L-1. A concentração de Bi3+ utilizado para a formação do filme foi de 1,0x10-4 mol L-1. O estudo da concentração dos íons Bi3+ utilizado para a formação do filme mostrou-se um parâmetro que afeta crucialmente o formato das curvas analíticas para ambos os metais Cd e Pb, apresentando variações na sensibilidade do método para ambos os metais e dificultando a determinação conjunta dos mesmos para concentrações mais baixas. A quantificação destes metais foi realizada em amostras de urina e de combustíveis como óleo Diesel e Biodiesel através do método de adição de padrões, os quais se apresentaram em faixas a nível de traços (µg.L-1). / The use of in situ Bismuth film modified electrodes is a practice method for the determination of metals by a preconcentration and anodic stripping, because the modification of electrode and preconcentration of analites in made simultaneously. The Au electrode manufacturing by CD-Rs is a cheap alternative method to build disposable electrodes, due the low cost and easily, with a unique CD-R is possible the production of a great number of electrodes whose possibility the realization of many measurements. When the preview behavior is anymore observed, the sensor is just discarded. This process is advantageous in the sense of after the stripping step, in which the pre-concentrated metals is getting out the electrode, the same cannot represent itself as the beginning profile, due a residual quantity of bismuth in the film remainder in the electrode. Because the easily of production of CD-R electrodes were made array of Au electrodes containing three electrodes, necessarily to electrochemistry cell, by the etching technique with iodide/iodine. This process was made using the protection of electrodes area with laser printer ink, by the thermal transference. After the etching, the toner ink is removed with swab cotton, absorbed in acetonitrile. A pseudo reference electrode (Ag/AgCl KCl 0,1 mol L-1) was incorporated to the system by electrodepositing of a Ag film on one of the three Au electrodes and following the reoxidation of a portion of Ag in a medium containing clorine ions to the formation of Ag/AgCl. The system show a good repeatability of square-wave voltammetry measures carry out through the preconcentration on Bi film formed in situ of Pb and Cd in a concentration of 2,0x10-6 mol L-1. The concentration of Bi3+ utilized to formation of in situ film was 1x10-4 mol L-1. The study of Bi3+ ions concentration shows that the same is an important parameter who affects crucially the format of analytical curves for both metals Cd e Pb, presenting variations in the sensibility of method for both metals and difficulting the simultaneous determination of these metals for lower concentrations. The quantification of theses metals was realized in urine and fuel oils, as Diesel oil and Biodiesel samples by the standard-addition method, whose was found in traces level concentration (&#181g L-1)
6

Desenvolvimento e aplicações de eletrodos de ouro confeccionados a partir de discos compactos graváveis (CD-Rs) / Development and applications of gold electrodes confectioned from recordable compact disc (CD-RS)

Eduardo Mathias Richter 22 January 2001 (has links)
O presente trabalho descreve uma forma inédita e simples de construção de eletrodos de ouro (CDtrodos) a partir de discos compactos graváveis (CD-Rs). Os CD-Rs possuem em sua constituição uma película de ouro com uma espessura entre 50 e 100 nm e com área aproximada de 100 cm2. Esta superfície de ouro pode ser facilmente utilizada para construção de eletrodos convencionais usados em células estacionárias ou em células em fluxo. Além disso, a espessura nanométrica do filme de ouro também pode ser utilizada para construção de microeletrodos de banda com áreas inferiores a 10-6 cm2. Devido ao fato do CD-R ser produzido em escala comercial, o custo do mesmo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Para comprovar a viabilidade da utilização destes filmes na confecção de eletrodos, seu desempenho foi comparado com o de eletrodo de ouro comercial, sendo observado um comportamento análogo. Diferentes maneiras de utilização do disco compacto gravável foram testadas, tanto em amostras sintéticas, como também, em amostras reais. Utilizando o método de redissolução potenciométrica à corrente constante (CCPSA), foram analisadas amostras de mercúrio em água potável e em água do mar, adaptando o CD-R a uma célula de injeção em fluxo. Nestes estudos, o limite de detecção de mercúrio situou-se em 250 ng L-1, utilizando-se tempo de deposição de 300 segundos. Estudos preliminares em células estacionárias levaram a limites de detecção inferiores. Em célula estacionária, foram realizadas análises de cobre em aguardente e em água potável. Em alguns casos, os resultados obtidos com as amostras reais foram comparados com outra técnica (E.A.A.), onde os resultados obtidos foram muito próximos a àqueles obtidos com os eletrodos de ouro. Análises em água de abastecimento, mostraram que em células estacionárias o limite de detecção para cobre situa-se em 30 ng L-1, para tempos de deposição de 600 segundos. / This work describes an original and novel form of construction of gold electrodes (CDtrodes) from recordable CDs (CD-Rs). The CD-Rs contain in its constitution a fine gold layer with a thickness from 50 to 100 nm and an approx. 100 cm2 of area. This surface can be easily used for construction of conventional electrodes for stationary or flow electrochemical cells. Moreover, the nanometer thickness of the gold film can be employed for the construction of microelectrodes with areas smaller than 10-6 cm2. Due to the fact that CD-Rs are produced on commercial scale, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. To prove the suitability of these films to make gold electrodes, their performance was compared with the response of a commercial electrode, and a similar behavior was observed. Different applications of recordable compact disk were tested either with synthetic or real samples. Using the Constant-Current Potentiometric Stripping Analysis (CCPSA) method, mercury was analyzed in seawater and drinking water samples, fitting the CD-R to flow injection analysis cell. In these studies, the detection limit for mercury was found to be 250 ng L-1, with a deposition time of 300 seconds. Preliminary studies involving stationary cells allowed lower detection limits for mercury to be attained. With a stationary cell, the analyses of copper in sugar cane spirits and drinking water were carried out. In some instances, comparisons were made between this and another analytical technique (namely A.A.S.) where the results were very close with the ones obtained with the gold electrodes. Analysis of drinking water showed that for stationary cells the detection limit for copper is 30 ng L-1, with a deposition time of 600 s.

Page generated in 0.0682 seconds