• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 405
  • 139
  • 30
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • Tagged with
  • 652
  • 400
  • 367
  • 163
  • 162
  • 153
  • 143
  • 121
  • 111
  • 105
  • 104
  • 85
  • 81
  • 76
  • 70
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Clinical evaluation of compomer, a polyacid-modified composite resin, in primary teeth : 1 year results /

Hse, Mei-yin, Kitty. January 1996 (has links)
Thesis (M.D.S.)--University of Hong Kong, 1996. / Includes bibliographical references (leaves 169-196).
92

Spectroscopic investigations of new glass-ionomer dental cements

Jin, Yigang. January 2000 (has links)
Thesis (M.S.)--West Virginia University, 2000. / Title from document title page. Document formatted into pages; contains xii, 63 p. : ill. (some col.) Includes abstract. Includes bibliographical references.
93

Clinical evaluation of compomer, a polyacid-modified composite resin, in primary teeth 1 year results /

Hse, Mei-yin, Kitty. January 1996 (has links)
Thesis (M.D.S.)--University of Hong Kong, 1996. / Includes bibliographical references (leaves 169-196). Also available in print.
94

Air void characterization in fresh cement paste through ultrasonic attenuation using an immersion procedure

Darraugh, Natalie Ainsworth. January 2009 (has links)
Thesis (M. S.)--Civil and Environmental Engineering, Georgia Institute of Technology, 2010. / Committee Chair: Jacobs, Laurence; Committee Co-Chair: Kurtis, Kimberly; Committee Member: Kim, Jin-Yeon. Part of the SMARTech Electronic Thesis and Dissertation Collection.
95

Low temperature setting polymer-ceramic composites for bone tissue engineering /

Sethuraman, Swaminathan. Laurencin, Cato T. January 2005 (has links)
Thesis (Ph. D.)--Drexel University, 2005. / Includes abstract and vita. Includes bibliographical references (leaves 317-318).
96

Influência do cloreto de cálcio no tempo de presa, solubilidade, desintegração, pH e atividade antimicrobiana do MTA e do cimento Portland branco com radiopacificador /

Bortoluzzi, Eduardo Antunes. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência do acréscimo de 10% de cloreto de cálcio (CaCl2) no tempo de presa, solubilidade, desintegração, pH e atividade antimicrobiana do MTA Branco (MTA) e cimento Portland branco com radiopacificador (CPB). O ProRoot MTA (PRO), com e sem CaCl2, também foi incluído no teste de atividade antimicrobiana. O teste do tempo de presa inicial seguiu a especificação #57 da ADA e o do tempo de presa final a da ASTM (C266-03). Para os testes de solubilidade, desintegração e pH foram utilizados 6 anéis de teflon para cada cimento, medindo 4 mm de espessura e 12 mm de diâmetro interno com parede de 2 mm. Depois de preenchidos, os anéis foram mantidos por 24 e 72 h e 7, 14 e 28 dias em água MiliQ, que foi renovada no fim de cada período. Após cada período, os cimentos foram desidratados em dessecador com sílica por 24 h. Foi registrado o peso de cada cimento hidratado e desidratado. O pH da água onde os cimentos permaneceram imersos foi medido por um pHmetro. A atividade antimicrobiana foi avaliada pela técnica da difusão em ágar, empregando o método do poço. Os microrganismos utilizados foram procedentes da ATCC: Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Candida albicans, Staphylococcus epidermidis. O acréscimo do CaCl2 proporcionou uma diminuição de 50% do tempo de presa inicial dos cimentos. Já o tempo de presa final do MTA foi diminuído em 35,5% e o do CPB em 68,5%. Os resultados do teste de solubilidade mostraram que o MTA+CaCl2 absorveu água e não perdeu peso com o passar do tempo, exceto no período de 24 h. O MTA, tanto hidratado quanto desidratado, perdeu peso, mas com valores aceitáveis pela ADA. O CPB apresentou maior solubilidade, a qual foi diretamente proporcional ao tempo de imersão das amostras. Entretanto, o acréscimo do CaCl2 ao CPB diminuiu...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of adding 10% calcium chloride (CaCl2) on the setting time, solubility and dissolution, pH, and antimicrobial activity of white MTA (MTA) and Portland cement with radioopacifier (CPB). ProRoot MTA (PRO) with and without CaCl2 was also included in the antimicrobial activity test. Setting time testing followed the specification #57 of ADA and final setting time testing was made according to C266-03 ASTM standard. Six teflon rings (4 mm thickness, 12 mm internal diameter, 2 mm height) used for the solubility, dissolution, and pH tests were stored in deionized water for 24h, 72 h, 7d, 14d, and 28d, which was renewed at the end of each storage period. After the storage periods, the specimens were dehydrated in a desiccator containing silica gel for 24h. The specimens were weighted before and after dehydration and pH of water was measured using a pH-meter. Antimicrobial activity was evaluated using an Agar well diffusion technique. The following microorganisms were used: Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Candida albicans, and Staphylococcus epidermidis (ATCC). Adding of CaCl2 yielded a 50% reduction of the initial setting of the cements. Final setting time of MTA cement was reduced approximately 35.5% and CPB's final setting time was reduced by 68.5%. Solubility results have shown that the MTA+ CaCl2 absorbed water and did not lost weight with time, except for the 24h-storage period. Hydrated and dehydrated MTA presented weight loss, but within acceptable limits stated by ADA. CPB presented greater solubility, proportional to the immersion time, i.e., the greater the storage period the greater the weight loss. However, adding CaCl2 to the CPB did not decrease the solubility. Both CPB and CPB+ CaCl2 did not satisfy ADA requirements. (Complete abstract, click electronic access below) / Orientador: Roberto Miranda Esberard / Coorientador: Clovis Monteiro Bramante / Banca: Marco Antônio Hungaro Duarte / Banca: Wilson Tadeu Felippe / Banca: Mario Tanomaru Filho / Banca: Idomeo Bonetti Filho / Doutor
97

Influência do tempo de endurecimento no comportamento físico e biológico de sete cimentos endodônticos

França, Monique Costa Moreira [UNESP] 18 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-18. Added 1 bitstream(s) on 2015-09-17T15:47:05Z : No. of bitstreams: 1 000843350.pdf: 2776777 bytes, checksum: 117622a7940320916a6831aad9adae9a (MD5) / Objetivo: O objetivo deste estudo foi avaliar a influência do tempo de endurecimento sobre as propriedades físicas (teste de push-out) e biológicas (XTT, MNT) de sete cimentos endodônticos: Apexit Plus, Real Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone N e o cimento biocerâmico iRoot SP. Material e Métodos: Para a análise da citotoxicidade (XTT), foram utilizados fibroblastos do ligamento periodontal humano (PDLF). Para o número de micronúcleos (MNT), este estudo avaliou culturas de células expostas a diluições dos cimentos testados sobre células V79 No teste de push-out foram usados cento e quarenta dentes humanos unirradiculares que tiveram suas coroas removidas. Os canais radiculares foram preparados biomecanicamente com o sistema rotatório Mtwo (VDW GmbH, München, Alemanha) até o número de série 702 a 25 mm (25-40). Durante todo o preparo biomecânico, os canais foram irrigados com 2 ml de hipoclorito de sódio. Os espécimes foram seccionados em fatias de 2 mm nos terços cervical, médio e apical. O teste de Push-out foi realizado a uma velocidade de 1 mm / min e célula de carga de 50 Kgf. Os testes biológicos foram avaliadas após 24 h, 72 h, 1 semana, 1 mês, 3 meses, 6 meses e um ano após a manipulação e o teste de push-out 15 dias e 1 ano.Os dados foram analisados pelo teste de Kruskal-Wallis e teste de Dunn (p = 0,05). Resultados: IRooot SP, Roeko seal, Apexit Plus, AH Plus e Real Seal não mostraram citotoxicidade nas células PDLF. AH Plus, Real Seal, IRooot SP e Endomethasone N não apresentaram genotoxicidade. Roeko Seal e Apexit Plus mostraram ser genotóxico e EndoRez apresentou alta genotoxicidade. Roeko Seal, IRooot SP e EndoRez tiveram menor resistência à tração nos terços apical, médio e cervical, tanto em 15 dias e 1 ano de análise. Além disso, Endomethasone N, Real Seal e AH Plus apresentaram uma força de adesão satisfatória após 1 ano em todos os terços. Conclusão: conclui-se que... / Objective: The aim of this study was to evaluate the influence of curing time on physical (push-out test) and biological properties (XTT, MNT) of seven sealers: Apexit Plus, Royal Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone, and bioceramic cement iRoot SP. Material and Methods: To the citotoxity analysis (XTT), fibroblasts of the human periodontal ligament were used (PDLF). To the number of micronuclei (MNT), this study evaluated cell cultures exposed to dilutions of the tested sealers, among them from causing excessive cytotoxic effects on V79 cells. To push-out test was used one hundred and forty single-rooted teeth which had the crowns removed. The root canals were prepared biomechanically with the rotary system Mtwo (VDW GmbH, München, Alemanha) until to series number 702 to file 25 mm (25-40). Throughout the biomechanical preparation, the canals were irrigated with 2 ml of sodium hypochlorite. The specimens were sectioned in slices of 2 mm in cervical, middle and apical. The push-out test was performed at speed of 1 mm/min and 50 kgf load cell. The tests were evaluated after 24 h, 72 h, 1 week, 1 month, 3 months, 6 months and one year after manipulation. Data were analyzed by Kruskal-Wallis and Dunn test (p = 0.05). Results: IRooot SP, Roeko Seal, Apexit Plus, AH plus and Real Seal showed no cytotoxicity in PDLF cells. AH plus, Real Seal, IRooot SP and Endomethasone N showed no genotoxicity. Roeko Seal and Apexit Plus have shown to be genotoxic and EndoRez showed high genotoxicity. Roeko Seal, IRooot SP and EndoRez had lower bond strength in the apical, middle and cervical thirds in both the 15-day and 1 year analysis. Apexit Plus, Endomethasone N, Real Seal and AH plus had a satisfactory bond strength after 1 year in all thirds. Conclusion: It is conclude that AH plus and Real Seal were the sealer with lower cytotoxicity and genotoxicity, with good values of bond strength in all third, keeping as the material of choice for....
98

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23)

Pontes, Elaine Cristina Voltolini [UNESP] 25 February 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-25Bitstream added on 2014-12-02T11:21:06Z : No. of bitstreams: 1 000796605.pdf: 2231117 bytes, checksum: 2cb8d762ad76e855d47d13daf8e4e4f2 (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells.
99

Avaliação da biocompatibilidade de quatro agentes para cimentação através do estudo das reações teciduais em conjuntivo da ratos

Nogueira Junior, Lafayette [UNESP] 28 June 2001 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-28Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1 000138163.pdf: 5037696 bytes, checksum: 2e83c40009b352ce450b85f1a580ef36 (MD5) / A biocompatibilidade de quatro agentes para cimentação de peças protéticas foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Neste trabalho foram avaliados um cimento de fosfato de zinco (Lee Smith - Vigodent), um cimento de ionômero de vidro (Ketac-Cem - ESPE) e dois cimentos resinosos (Panavia Ex 21 - Kuraray Co.; Enforce- Dentsply). Após a manipulação dos cimentos, os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os agentes cimentantes e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos períodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram que todos os agentes de cimentação causaram uma resposta tecidual nos períodos avaliados; o cimento de fosfato de zinco apresentou um menor grau de reação tecidual nos períodos de 14, 30 e 60 dias; o cimento de ionômero de vidro apresentou as piores características de biocompatibilidade quando em contata com o tecido conjuntivo de ratos / The biocompatibility of four luting agents was evaluated in rats subcutaneous connective tissue implants. Polyethylene lubes filled with the luting agents were surgically implanted into the dorsal subcutaneous tissue of rats. The tube was left implanted for periods of 14, 30, 60 and 84 days, following wich the animals were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microspic . The results showed that all the luting caused an tissue answer in the appraised periods; the phosphate of zinc cement presented a smaller degree of tissue reaction in the periods of 14, 30 and days; the of glass ionomer cement presented the worst characteristics of biocompatibility when in contact with the conjunctive tissue in rats
100

Influência do tempo de endurecimento no comportamento físico e biológico de sete cimentos endodônticos /

França, Monique Costa Moreira. January 2014 (has links)
Orientador: Carlos Henrique Ribeiro Camargo / Banca: Cláudio Antonio Talge Carvalho / Banca: Renato Miotto Palo / Resumo: Objetivo: O objetivo deste estudo foi avaliar a influência do tempo de endurecimento sobre as propriedades físicas (teste de push-out) e biológicas (XTT, MNT) de sete cimentos endodônticos: Apexit Plus, Real Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone N e o cimento biocerâmico iRoot SP. Material e Métodos: Para a análise da citotoxicidade (XTT), foram utilizados fibroblastos do ligamento periodontal humano (PDLF). Para o número de micronúcleos (MNT), este estudo avaliou culturas de células expostas a diluições dos cimentos testados sobre células V79 No teste de push-out foram usados cento e quarenta dentes humanos unirradiculares que tiveram suas coroas removidas. Os canais radiculares foram preparados biomecanicamente com o sistema rotatório Mtwo (VDW GmbH, München, Alemanha) até o número de série 702 a 25 mm (25-40). Durante todo o preparo biomecânico, os canais foram irrigados com 2 ml de hipoclorito de sódio. Os espécimes foram seccionados em fatias de 2 mm nos terços cervical, médio e apical. O teste de Push-out foi realizado a uma velocidade de 1 mm / min e célula de carga de 50 Kgf. Os testes biológicos foram avaliadas após 24 h, 72 h, 1 semana, 1 mês, 3 meses, 6 meses e um ano após a manipulação e o teste de push-out 15 dias e 1 ano.Os dados foram analisados pelo teste de Kruskal-Wallis e teste de Dunn (p = 0,05). Resultados: IRooot SP, Roeko seal, Apexit Plus, AH Plus e Real Seal não mostraram citotoxicidade nas células PDLF. AH Plus, Real Seal, IRooot SP e Endomethasone N não apresentaram genotoxicidade. Roeko Seal e Apexit Plus mostraram ser genotóxico e EndoRez apresentou alta genotoxicidade. Roeko Seal, IRooot SP e EndoRez tiveram menor resistência à tração nos terços apical, médio e cervical, tanto em 15 dias e 1 ano de análise. Além disso, Endomethasone N, Real Seal e AH Plus apresentaram uma força de adesão satisfatória após 1 ano em todos os terços. Conclusão: conclui-se que... / Abstract: Objective: The aim of this study was to evaluate the influence of curing time on physical (push-out test) and biological properties (XTT, MNT) of seven sealers: Apexit Plus, Royal Seal, Endo Rez, Roeko Seal, AH Plus, Endomethasone, and bioceramic cement iRoot SP. Material and Methods: To the citotoxity analysis (XTT), fibroblasts of the human periodontal ligament were used (PDLF). To the number of micronuclei (MNT), this study evaluated cell cultures exposed to dilutions of the tested sealers, among them from causing excessive cytotoxic effects on V79 cells. To push-out test was used one hundred and forty single-rooted teeth which had the crowns removed. The root canals were prepared biomechanically with the rotary system Mtwo (VDW GmbH, München, Alemanha) until to series number 702 to file 25 mm (25-40). Throughout the biomechanical preparation, the canals were irrigated with 2 ml of sodium hypochlorite. The specimens were sectioned in slices of 2 mm in cervical, middle and apical. The push-out test was performed at speed of 1 mm/min and 50 kgf load cell. The tests were evaluated after 24 h, 72 h, 1 week, 1 month, 3 months, 6 months and one year after manipulation. Data were analyzed by Kruskal-Wallis and Dunn test (p = 0.05). Results: IRooot SP, Roeko Seal, Apexit Plus, AH plus and Real Seal showed no cytotoxicity in PDLF cells. AH plus, Real Seal, IRooot SP and Endomethasone N showed no genotoxicity. Roeko Seal and Apexit Plus have shown to be genotoxic and EndoRez showed high genotoxicity. Roeko Seal, IRooot SP and EndoRez had lower bond strength in the apical, middle and cervical thirds in both the 15-day and 1 year analysis. Apexit Plus, Endomethasone N, Real Seal and AH plus had a satisfactory bond strength after 1 year in all thirds. Conclusion: It is conclude that AH plus and Real Seal were the sealer with lower cytotoxicity and genotoxicity, with good values of bond strength in all third, keeping as the material of choice for.... / Mestre

Page generated in 0.0671 seconds