• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • Tagged with
  • 33
  • 33
  • 32
  • 11
  • 10
  • 9
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Resistência ao cisalhamento de brackets ortodônticos com diferentes tratamentos de superfície e cerâmicas

May, Naudy Brodbeck January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-16T01:37:40Z (GMT). No. of bitstreams: 1 225721.pdf: 8647127 bytes, checksum: ec8fd37c2ae3b18659c05c993a86a03a (MD5) / Este estudo avaliou a resistência ao cisalhamento da união bracket/cerâmica, após diferentes pré-tratamentos da superfície cerâmica. Foram selecionadas duas cerâmicas (Eris e d.Sign) e os materiais (óxido de alumínio, CoJet, agente silano, concise, ácido fluorídrico a 10%, ácido fosfórico a 35%). Pôde-se concluir que: 1) as duas cerâmicas desempenharam papel similar; 2) a utilização do silano após condicionamento com ácido fluorídrico foi responsável pelo aumento nos valores de união; 3) o pré-tratamento por meio do condicionamento com ácido fluorídrico a 10% por 20s e utilização de agente silano, bem como o jateamento com óxido de alumínio (50 m) por 15s,seguido do condicionamento com ácido fosfórico a 35% e aplicação do agente silano, promoveram os mais altos valores de resistência da união; 4) a utilização do sistema CoJet não resultou em valores estatisticamente superiores aos observados no tratamento com óxido de alumínio, igualando-se aos grupos tratados com ácido fluorídrico sem aplicação de silano; 5) o jateamento com óxido de alumínio, seguido do condicionamento com ácido fosfórico e silano apresentou resultados semelhantes ao tratamento com ácido fluorídrico e silano.
32

Efeito de diferentes tratamentos superficiais em uma liga níquel-cromo na resistência e microestrutura de sua união com cerâmicas odontológicas

Pereira, Sílvia Fontes do Amaral 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência e Engenharia de Materiais, Florianópolis, 2009. / Made available in DSpace on 2012-10-24T11:43:08Z (GMT). No. of bitstreams: 0 / O objetivo do presente estudo in vitro foi verificar, através de teste de cisalhamento, a resistência de união da liga WironiaÒlight, a base de níquel-cromo sem berílio, sujeita a diferentes tratamentos de superfície, às cerâmicas Vita VM13 e Noritake. Foram confeccionados oitenta espécimes cilíndricos metálicos, nas dimensões de 4 mm de diâmetro por 5 mm de altura, que tiveram suas superfícies avaliadas em Microscópio Eletrônico de Varredura (MEV) associado ao espectrômetro dispersivo em energia de raios-X (EDS). Os espécimes foram divididos em oito grupos (n=10), de acordo com o tipo de tratamento superficial aplicado à liga metálica e com o tipo de cerâmica testada: sem qualquer tratamento; jateamento com óxido de alumínio; ataque com ácido fluorídrico 55%; utilização de broca diamantada. Os corpos-de-prova foram colocados no interior de matriz de aço inoxidável, para estabilização dos mesmos, e levados à máquina de ensaio mecânico universal, onde a cerâmica exposta teve a força medida por célula de carga de 50kgf do aparelho, com velocidade de 0,5 mm/min. A tensão de resistência à fratura foi registrada em MPa. Os espécimes foram avaliados segundo os critérios de resistência ao cisalhamento medindo-se a área de cerâmica remanescente aderida ao metal com o auxílio de microscopia óptica e analisando através MEV e EDS as regiões cerâmicas e metálicas dos grupos após a fratura. No que tange à resistência à fratura, o teste de Tukey (p> 0,05), demonstrou que os corpos-de-prova de Cerâmica Noritake com jateamento (26,40 ± 11,63 MPa) e Cerâmica Vita sem tratamento de superfície (26,35 ± 6,51 MPa) apresentaram maior resistência ao cisalhamento enquanto que os menores valores foram registrados nos espécimes de Cerâmica Vita com utilização de broca (13,44 ± 7,76 MPa), sendo este o único grupo com diferença estatisticamente significante. Quanto à cerâmica remanescente, a aplicação do teste de Kruskall-Wallis (p> 0,05), demonstrou diferenças significativas entre os grupos. Através da análise das medianas, constatou-se que o grupo Noritake com jateamento (15,5%) apresentou a maior área de cerâmica aderida ao metal enquanto que o grupo da Cerâmica Vita com broca (1,8%) apresentou a menor área. Os problemas relacionados às falhas de adesão metal/cerâmica estão intimamente relacionados à manipulação e manuseio dos materiais pelos técnicos de laboratório que devem seguir rigorosamente as informações dos fabricantes. Concluiu-se que a Cerâmica Noritake com jateamento, obteve os valores mais altos de resistência ao cisalhamento e de remanescente cerâmico aderido à superfície metálica enquanto que o grupo Cerâmica Vita tratado com broca diamantada obteve os valores mais baixos. / The aim of the this in vitro study was to verify, by means of the shear bond strength test, the bond strength of the nickel-chrome based alloy without berylium, WironiaÒlight, subjected to different surface treatments, to Vita VM13 and Noritake ceramics. Eigthy cylindrical metal specimens, measuring 4 mm in diameter by 5 mm high, whose surfaces were evaluated by Scanning Electron Microscopy (SEM) associated energy dispersive spectrometry with x-ray (EDS). The specimens were divided into eigth groups (n=10), according to the type of surface treatment applied to the metal alloy and with the type of ceramic tested: without metal surface treatment; aluminum oxide airborne particle abrasion; etching with 55% fluoridric acid; and use of diamond bur. The test specimens were put into the stainless steel matrix to stabilize them, and taken to the universal mechanical test machine, to which the exposed ceramic was subjected and the strength mensureted with 50kgf load cell, at a speed of 0.5 mm/min. The fracture strength stress was recorded in MPa. The specimens were evaluated according to the shear strength criteria, measuring it remaining ceramics area adhered to the metal with the aid of optic microscopy and analyzing through MEV and EDS the ceramic and metallic regions the groups after the breaking. With regard to fracture strength, the Tukey test (p> 0.05), showed that the test specimens made of Noritake Ceramic treated with airborne particle abrasion (26,40 ± 11,63 MPa) and Vita Ceramic without metal surface treatment (26,35 ± 6,51 MPa) presents the highest shear bond strength, whereas the lowest values were recorded for the Vita Ceramic specimens treated with the use of a bur (13.44 ± 7.76 MPa), this being the only group with statistically significant difference. With regard to the remaining ceramic, the application of the Kruskall-Wallis test (p> 0.05), showed significant differences among the groups. By means of analysis of the medians, it was found that the Noritake group treated by airborne particle abrasion (15,5%) presented the largest area of ceramic adhered to metal, whereas the Vita Ceramic group treated with the bur (1,8%) presented the smallest area. The problems related to the imperfections of ceramic adhesion metal/closely are related to the manipulation and manuscript of the materials for the technician of laboratory who must rigorously follow the information of the manufacturers. It was concluded that Noritake Ceramic group with airborne particle abrasion presented the higher values of shear bond strength and remained ceramic adhered to the metal while the Vita Ceramic specimens treated with the use of a bur got the lowest values.
33

Desenvolvimento de um dinamômetro digital para padronização da força de cimentação e sua influência na espessura de película de restaurações cerâmicas

Barbosa, Marcelo Taveira January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-16T04:17:57Z (GMT). No. of bitstreams: 1 314247.pdf: 6941180 bytes, checksum: b9d1362388c6a5ff1a943eaea3d68703 (MD5) / O objetivo deste estudo foi propor uma padronização da força na técnica de cimentação. Inicialmente, desenvolveu-se um dinamômetro digital, aplicável clinicamente, para padronizar a força de cimentação. Em seguida, realizou-se uma avaliação comparativa da adaptação interna de coroas cerâmicas cimentadas com força manual e com o dinamômetro. Dez molares humanos receberam preparo para coroa total. Para cada molar confeccionou-se uma coroa cerâmica pelo sistema injetável de IPS Empress 2 e cobertura com cerâmica IPS e.max Ceram. Para os testes, um manequim com os dentes naturais foi acoplado a uma cabeça simulando lábios e bochechas. Para a cimentação, cada coroa foi preenchida com o silicone de adição específico recém-manipulado e imediatamente adaptada a seu respectivo dente. No grupo mecânico, a ponteira do dinamômetro foi inserida na cavidade oral, e a ponta com o silicone de proteção foi posicionada sobre a coroa cerâmica. A mordida foi estabilizada por 3min com uma força de ~20,00N. Para a cimentação manual, selecionaram-se três operadores com pós-graduações. Cada operador executou a força de cimentação, com a carga que julgou ser adequada, por 3min. Após, realizaram-se os cortes transversais das réplicas nos sentidos vestibulolingual e mésio-distal. Para cada um dos 4 segmentos foram realizadas três mensurações em cada local (cervical, axial e oclusal). As médias finais das espessuras de películas foram de 86,48µm para o grupo mecânico e de 103,58µm, 103,05µm e104,49µm para os grupos de cimentação manual. Embora as médias não tenham sido estatisticamente diferentes, a cimentação com o auxílio do dinamômetro padronizou a força de cimentação, evitando forças exageradamente baixas ou excessivas, e diminuiu a dependência da auxiliar, liberando as mãos do profissional para a remoção de excessos, conferências das margens e estabilização da restauração indireta

Page generated in 0.1125 seconds