• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 241
  • 38
  • 7
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 310
  • 240
  • 61
  • 40
  • 40
  • 37
  • 36
  • 35
  • 35
  • 31
  • 30
  • 29
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

The Effect of Chlorhexidine Gluconate as an Endodontic Irrigant on the Apical Seal: Long-term Results

Ferguson, David B. 01 January 2003 (has links)
The purpose of this study was to determine whether chlorhexidine gluconate (0.12%), used as an endodontic irrigating solution would affect the apical seal of three root canal cements. One hundred extracted human single-canal teeth were divided into 9 experimental groups of 10 teeth each, in addition to a positive and negative control group of 5 teeth each. The teeth were decoronated at the level of the cementoenamel junction, accessed, instrumented to a Master Apical File #50, irrigated with either sterile saline, 5.25% NaOCl or 0.12% chlorhexidine gluconate, and dried using paper points. Obturation was accomplished using lateral condensation and one of three endodontic sealers: Roth's 811, AH26, or Sealapex. Post-obturation apical leakage was measured at 270- and 360-day observation periods using the fluid filtration method. Using the mixed-model repeated-measures ANOVA test with Tukey's HSD multiple comparison procedure, the results showed the saline-Sealapex combination had significantly more leakage (p<0.05) than either the Peridex-Sealapex or saline-Roth's combinations at 270 days. No other significant differences were noted between any sealer-irrigant combination at 270 days. The saline-Sealapex combination had significantly more leakage than the saline-Roth's combination at 360 days. No other significant differences were noted at 360 days. Under the conditions of this study, chlorhexidine gluconate irrigant did not adversely affect the apical seal of three root canal cements at 270 and 360 days.
82

Contribution à la mise au point d'un système mucoadhésif thermoréversible pour une libération topique contrôlée d'un médicament modèle

Gouda, Noha Mamdouh Zaky-Eldine January 2006 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
83

Avaliação da presença de microrganismos periodontopatogênicos em amostras subglóticas de pacientes intubados e mecanicamente ventilados, submetidos a cirurgias eletivas / Evaluation of the presence of periodontopathogenic microorganisms in subglottic samples of intubated and mechanically ventilated patients submitted to elective surgeries

Morillo, Carlos Manuel Rubio 25 February 2019 (has links)
A pneumonia associada à ventilação mecânica (PAVM) é uma condição inflamatória infecciosa cuja etiopatogenia ainda está mal definida. Embora a principal via de infecção do trato respiratório inferior permaneça desconhecida, a colonização do trato orofaríngeo é geralmente considerada como a principal via de infecção para PAVM. Desta forma, o objetivo deste estudo foi avaliar a presença de microrganismos periodontopatogênicos em amostras subglóticas de pacientes intubados e mecanicamente ventilados, submetidos a cirurgias eletivas. Adicionalmente, este estudo avaliou o impacto do estado de saúde periodontal e da descontaminação bucal com clorexidina (CHX) na quantificação destes microrganismos. Foram incluídos 43 pacientes programados para cirurgia eletiva sob anestesia geral com intubação orotraqueal. Um exame periodontal de boca toda foi realizado anteriormente a cirurgia. A periodontite foi definida como: i) dois ou mais sítios interproximais com nível clínico de inserção (NIC) >=4 mm ou dois ou mais sítios interproximais com profundidade clínica de sondagem (PCS) >= 5 mm (Definição 1); ii) NCI >= 4 mm ou PCS >= 5 mm em pelo menos seis sítios interproximais (Definição 2); e iii) NCI >= 4 mm ou PCS >= 5 mm em pelo menos dois sítios interproximais em cada quadrante (Definição 3). No dia da cirurgia, os pacientes foram randomizados em dois grupos que fizeram um enxague intraoral com 15 ml de CHX 0,12% (teste) ou solução salina (controle) por 30 segundos. Após 3h de intubação orotraqueal, o conteúdo da região subglótica foi aspirado e armazenado a -80ºC. A quantificação de Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans), Porphyromonas gingivalis (P. gingivalis) e Tannerella forsythia (T. forsythia) foi feita pela reação em cadeia da polimerase quantitativa em tempo real. As contagens de P. gingivalis, T. forsythia e A. actinomycetemcomitans não diferiram entre pacientes periodontalmente saudáveis e aqueles diagnosticados com periodontite, independentemente da definição de periodontite (p> 0,05). De forma análoga, nenhum dos parâmetros periodontais avaliados tiveram impacto nas contagens subglóticas de P. gingivalis, T. forsythia e A. actinomycetemcomitans (p> 0,05). Por fim, o grupo que recebeu um enxague intraoral único pré-intubação com CHX 0,12% apresentou níveis reduzidos de P. gingivalis e A. actinomycetemcomitans em amostras do conteúdo subglótico. Em resumo, este estudo demonstrou presença de microrganismos periodontopatogênicos na região subglótica de pacientes intubados e mecanicamente ventilados. Enquanto a descontaminação intraoral em dose única com CHX foi associada com níveis reduzidos de A. actinomycetemcomitans e P. gingivalis, o estado de saúde periodontal não interferiu nos níveis de A. actinomycetemcomitans, P. gingivalis e T. forsythia na região subglótica. / Ventilator-associated pneumonia (VAP) is an infectious inflammatory condition whose etiopathogenesis is still poorly defined. Although the main route of infection to the lower respiratory tract remains unknown, colonization of the oropharyngeal tract is generally considered the main route of infection for VAP. Thus, the objective of this study was to evaluate the presence of periodontopathogenic microorganisms in subglottic samples of intubated and mechanically ventilated patients submitted to elective surgeries. Furthermore, this study evaluated the impact of periodontal health status and oral decontamination with chlorhexidine (CHX) on the quantification of these microorganisms. 43 patients scheduled for elective surgery under general anesthesia with orotracheal intubation were included. Full-mouth periodontal examination was performed prior to surgery. Periodontitis was defined as: i) two or more interproximal sites with clinical attachment level (CAL) >=4 mm or two or more interproximal sites with clinical probing depth (CPD) >= 5 mm (Definition 1); ii) CAL >= 4 mm or CPD >= 5 mm in at least six interproximal sites (Definition 2); and iii) CAL >= 4 mm or CPD >= 5 mm in at least two interproximal sites in each quadrant (Definition 3). On the day of surgery, patients were randomized into two groups that rinsed preoperatively with 15 ml CHX 0.12% (test) or saline (control) for 30 seconds. After 3h of orotracheal intubation, the contents of the subglottic region were aspirated and stored at -80°C. Quantification of Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans), Porphyromonas gingivalis (P. gingivalis) and Tannerella forsythia (T. forsythia) was done by quantitative real-time polymerase chain reaction. P. gingivalis, T. forsythia, and A. actinomycetemcomitans counts did not differ between periodontally healthy patients and those diagnosed with periodontitis, regardless of the definition of periodontitis (p> 0.05). Similarly, none of the periodontal parameters evaluated had an impact on the subglottic counts of P. gingivalis, T. forsythia and A. actinomycetemcomitans (p> 0.05). Finally, the group receiving a single pre-intubation intraoral rinse with CHX 0.12% presented reduced levels of P. gingivalis and A. actinomycetemcomitans in samples of the subglottic content. In summary, this study demonstrated the presence of periodontopathogenic microorganisms in the subglottic region of intubated and mechanically ventilated patients. While a single dose intraoral decontamination with CHX was associated with reduced levels of A. actinomycetemcomitans and P. gingivalis, the periodontal health status did not affect the levels of A. actinomycetemcomitans, P. gingivalis and T. forsythia in the subglottic region.
84

Candida spp. em escovas dentais e eficácia de antimicrobianos na sua desinfecção / Candida spp. on toothbrushes and efficacy of antimicrobial agents for their disinfection.

Rodrigues, Andresa Piacezzi Nascimento 21 May 2009 (has links)
Os objetivos foram avaliar a presença de Candida spp. em escovas dentais; a eficácia do Periogard® e do Neem Sattiva®, em spray, na desinfecção destas escovas; a atividade antimicrobiana, in vitro, do Neem Sattiva®, do Periogard® e da solução de gluconato de clorexidina a 0,5% por meio da Diluição Inibitória Máxima (DIMax); e a capacidade de Candida spp. formar biofilme, in vitro, sobre as cerdas e hastilhas de escovas dentais (empregando a técnica de cultura microbiana e a microscopia eletrônica de varredura). Participaram do estudo clínico randomizado 61 estudantes de Odontologia da FORP USP. O estudo foi realizado em três etapas. Em cada etapa, os voluntários receberam escovas novas e realizaram a escovação dentária sem dentifrício, por dois minutos. Cada solução foi borrifada sobre as cerdas das escovas por seis vezes. Após quatro horas à temperatura ambiente, as escovas foram submetidas ao processamento microbiológico para o isolamento e identificação das espécies de Candida. A DIMax dos antissépticos foi realizada utilizando o método da diluição em ágar. As escovas dentais de 37,3% dos indivíduos estavam contaminadas por Candida spp. (C. albicans, C. parapsilosis e Candida sp.). O Periogard® e o Neem Sattiva®, em spray, inibiram o crescimento de Candida spp. em 40,9 e 9,1% das escovas, respectivamente. Portanto, o spray de Periogard® foi mais eficaz que o spray de Neem Sattiva® para esse propósito. As DIMaxs do Neem Sattiva®, do Periogard® e da solução de clorexidina a 0,5% frente a 63 cepas de Candida spp. foram 1/10, 1/20 e 1/40, respectivamente. Candida spp. foram capazes de formar biofilme, in vitro, sobre hastilhas (polietileno de baixa densidade) de escovas dentais. O mesmo não ocorreu nas cerdas de náilon. / The purposes were to evaluate the presence of Candida spp. on toothbrushes; the efficacy of Periogard® and Neem Sattiva®, in spray, in the disinfection of these toothbrushes; the in vitro antimicrobial activity of Neem Sattiva®, Periogard® and solution containing 0.5% chlorhexidine gluconate by the Maximum Inhibitory Dilution (MID); and the ability of Candida spp. to form biofilm in vitro on the bristles and small sticks of toothbrushes (using the microbial culture technique and scanning electron microscopy). In the randomized clinical study participated 61 students matriculated at the Dentistry course of the FORP USP. The study was performed into three phases. In each phase, volunteers received new toothbrushes and performed toothbrushing with no dentifrice, during two minutes. Each solution was sprayed six times on the toothbrush bristles. After four hours at room temperature, toothbrushes were submitted to microbiological processing for the isolation and identification of Candida species. MID of antiseptics was performed using the agar dilution method. Toothbrushes used by 37.3% of subjects were contaminated by Candida spp. (C. albicans, C. parapsilosis and Candida sp.). Periogard® and Neem Sattiva®, in spray, inhibited growth of Candida spp. in 40.9 and 9.1% of toothbrushes, respectively. Therefore, Periogard® spray was more efficacious than Neem Sattiva® spray for this purpose. MID of Neem Sattiva®, Periogard® and solution containing 0.5% chlorhexidine against 63 Candida spp. strains were 1/10, 1/20 and 1/40, respectively. Candida spp. were able to form biofilm in vitro on the toothbrush small sticks (low-density polyethylene). This did not occur on the nylon bristles.
85

Influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada híbrida e camada de adesivo / The influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the hybrid layer and adhesive layer

Lobo, Tamile Rocha da Silva 03 September 2013 (has links)
Este estudo avaliou a influência do uso do digluconato de clorexidina como inibidor de metaloproteinase na resistência adesiva e dureza da camada de adesivo e camada hibrida de uma resina composta à dentina humana, por meio de ensaio de microtração e nanoedentação. Os fatores de variação estudados foram dois sistemas adesivos com estratégias de aplicação distintas Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) e Clearfil SE Bond (Kuraray Co., Osaka, Japan), e ainda foram realizados tratamentos no substrato dentinário utilizando duas concentrações de digluconato de clorexidina sendo estas 2% e 0,2% e grupos controle sem tratamento com clorexidina. As unidades experimentais foram compostas por 48 molares humanos hígidos divididos aleatoriamente em 6 grupos (n=8). Nestes foram aplicados os procedimentos adesivos e realizados os tratamentos de superfície, com clorexidina, previamente aos procedimentos adesivos. Após esta etapa foram confeccionadas as restaurações com espessura de 5mm sobre as superfícies dentinárias. Após 24h de armazenamento em água destilada, os dentes restaurados foram cortados para a obtenção de corpos de prova em forma de palito, com secção transversal de aproximadamente 1mm2. De cada grupo foram selecionados aleatoriamente 5 palitos para o ensaio de dureza. O restante dos palitos viáveis de cada dente foram submetidos ao teste de microtração a uma velocidade de 0,5mm/min até que ocorresse a fratura da interface adesiva. Para o teste de nanoedentação cada um dos 5 palitos referentes aos 6 grupos estudados receberam 10 endentações, sendo 5 na camada de adesivo e 5 na camada hibrida, com distância de 10m entre si. Essas endentações foram realizadas com ultramicrôdurometro (DUH-W211S, Shimadzu Co., Tokyo, Japan). Os dados referentes aos testes de microtração dos seis grupos foram submetidos à análise de variância e teste de Tukey (p<0,05). As médias dos grupos foram: Grupo 1: Clearfil SE controle ( 28.50±0.47); Grupo 2: Adper Scotchbond controle (43.90±7.26); Grupo3: Clearfil SE/ clorexidina 2% (30.43±6.59); Grupo 4: Adper Scotchbond/ clorexidina 2% (39.21±4.69); Grupo 5: Clearfil SE 0,2%( 27.28±7.05); Grupo 6: Adper Scotchbond/ clorexidina 0,2% (35.70±6.43). Na comparação entre as médias dos grupos obteve-se que nenhum dos adesivos testados apresentou alteração na sua resistência de união com o uso do digluconato de clorexidina a 2% ou a 0,2% em análise imediata. Os grupos em que foi utilizado o adesivo Scotchbond apresentaram maiores valores de resistência de união que os grupos em que foi utilizado o sistema adesivo autocondicionante (Clearfil) independente da realização ou não do tratamento de superfície com digluconato clorexidina. Os valores de dureza da camada de adesivo não apresentaram diferenças estatisticamente significantes entre os grupos controle ou entre tratamentos, apenas o grupo com tratamento prévio Clearfil SE/Clorexidina 0,2% apresentou maior valores de dureza na camada de adesivo quando comparado ao grupo Scotchbond com a mesma concentração de clorexidina. Quanto aos valores de dureza da camada híbrida o grupo controle Clearfil SE quando comparado ao grupo Clearfil SE/Clorexidina 2% apresentou menor valor de dureza da camada hibrida. O Scotchbond controle apresentou menor valor de dureza na camada hibrida quando comparado ao grupo Scotchbond com clorexidina a 0,2%. O uso do digluconato de clorexidina nas concentrações 2% e 0,2% em dentina humana, apesar de ter apresentado discretas alterações na dureza da camada hibrida e camada de adesivo, não tiveram a capacidade de afetaram os valores de adesão à dentina dos diferentes adesivos testados. / This study evaluated the influence of the use of chlorhexidine gluconate as an inhibitor of metalloproteinase bond strength and hardness of the adhesive layer and hybrid layer of a composite resin to dentin, using microtensile test and nanoindentation. The variation factors studied were two adhesive systems with different implementation strategies Adper Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) and Clearfil SE Bond (Kuraray Co., Osaka, Japan), and were still held treatments to dentin using two concentrations of chlorhexidine digluconate and these 2% and 0.2% untreated control groups with chlorhexidine. The experimental units were composed of 48 human molars were randomly divided into 6 groups (n = 8). These procedures were applied adhesives and surface treatments performed with chlorhexidine prior to bonding procedures. After this step the restorations were made with 5mm thickness on the dentin surfaces. After 24 hours storage in distilled water, the samples were cut to obtain specimens toothpick shaped cross-section of approximately 1mm2. Each group were randomly selected 5 toothpicks for hardness testing. The remaining viable sticks of each tooth were subjected to microtensile testing at a crosshead speed of 0.5 mm / min until the fracture of the adhesive interface. To test nanohardness each of the five toothpicks referring to six groups received 5 indentations in the adhesive layer and 5 indentations in the hybrid layer with 10m away from each other. These indentations were performed with the equipament DUH-W211S (Shimadzu Co., Tokyo, Japan). The data relating to microtensile test of the six groups were subjected to analysis of variance and Tukey test (p <0,05). The means of the groups were: Group 1: Clearfil SE control (28.50 ± 0:47), Group 2: Adper Scotchbond control (43.90 ± 7.26); Group3: Clearfil SE / 2% chlorhexidine (30.43 ± 6:59), Group 4: Adper Scotchbond / 2% chlorhexidine (39.21 ± 4.69), Group 5: Clearfil SE 0.2% (27.28 ± 07.05), Group 6: Adper Scotchbond / chlorhexidine 0.2% (35.70 ± 6:43). Comparing the means of the groups it was found that none of the adhesives tested showed a change in its bond strength with the use of chlorhexidine gluconate 2% or 0.2% in immediate analysis. The groups that used Scotchbond showed higher bond strength than the groups that used the adhesive system (Clearfil) regardless of performance or not the surface treatment with chlorhexidine digluconate. The hardness values of the adhesive layer did not show statistically significant differences between the control groups or between treatments, the group previously treated with Clearfil SE / Chlorhexidine 0.2% showed higher hardness values in the adhesive layer when compared to Scotchbond with the same concentration of chlorhexidine. As for the hardness of the hybrid layer control group Clearfil SE when compared to Clearfil SE / 2% Chlorhexidine showed lower hardness value of the hybrid layer. The Scotchbond control showed lower hardness value in the hybrid layer when compared to Scotchbond with 0.2% chlorhexidine.The use of chlorhexidine gluconate at concentrations 2% and 0.2% in human dentin, despite having discrete changes in the hardness of the hybrid layer and adhesive layer, did not have the ability to affect the values of adhesion to dentin of different adhesives tested.
86

Efeito do gluconato de clorexidina a 2% em gel, usado durante o preparo intrarradicular, na retenção de núcleos metálicos fundidos / The effect of the 2% chlorhexidine gel used during intracanal preparation in the retention of cast post cores

Silva, Ricardo Souza da 06 July 2007 (has links)
A recontaminação do sistema de canais radiculares durante os procedimentos de preparo do espaço para núcleos metálicos fundidos deve ser evitada, sob pena de falha do tratamento endodôntico. O uso de substâncias antimicrobianas durante o procedimento pode ser interessante. O objetivo deste estudo foi avaliar o efeito do uso do gluconato de clorexidina a 2% em gel ou soro fisiológico (grupo controle), em conjunto com brocas para o preparo intrarradicular, sobre a retenção de núcleos metálicos fundidos, cimentados com fosfato de zinco ou um cimento resinoso (Panavia F). Foram utilizados 40 pré-molares inferiores humanos hígidos. Estes dentes foram tratados endodonticamente e receberam preparos intrarradiculares de 10mm de profundidade, com as brocas número 2 de um sistema de pinos pré-fabricados de fibra de carbono. Em conjunto com estas brocas foi utilizado soro fisiológico (grupos 1 e 2 - controle) ou o gluconato de clorexidina em gel a 2% (grupos 3 e 4). Os condutos foram moldados e foram obtidos padrões em resina acrílica autopolimerizável. Os dentes foram incluídos em resina epóxica e depois em resina acrílica autopolimerizável. Os padrões foram fundidos em liga de níquel-cromo e cimentados com fosfato de zinco (grupos 1 e 3) ou Panavia F (grupos 2 e 4). Os espécimes foram mantidos em 100% de umidade relativa por 72 horas e em seguida, os pinos foram submetidos a forças de tração até serem desalojados. Os dados obtidos foram submetidos à análise de variância. Os valores das médias obtidas, em Kgf, foram: G1 - 21,744; G2 - 17,484; G3 - 25,229 e G4 - 20,028. Não houve diferença estatisticamente significante entre os grupos (p<0,05). Um protocolo de limpeza e desinfecção, para o preparo do espaço para pinos, deve ser estabelecido e o gluconato de clorexidina em gel a 2% não afetou negativamente a retenção de núcleos metálicos fundidos neste estudo. Estes dados sugerem que esta seja uma boa substância para auxiliar no preparo do espaço para pino, porque apresenta características vantajosas para o procedimento como: baixa toxicidade, fácil manuseio, atividade antimicrobiana e ação residual / Recontamination of the root canal during post space preparation must be avoided, under penalty of endodontic treatment failure. The use of antimicrobial substances in these procedures should be of interest. The aim of this study was to evaluate the retention of cast posts and cores luted with zinc phosphate cement and a resin cement (Panavia F), when burs and the 2% chlorhexidine gluconate in gel and saline were used for post space preparation. Forty sound human inferior premolars were used in this study. These teeth were treated endodontically, and had a 10mm length post space preparation with the number 2 burs of a carbon fiber post system. In adjunction with this burs saline (G1 and G2 - control) and 2% chlorhexidine gluconate in gel (G3 and G4) were used. Impressions were taken of the canals with acrylic resin. The teeth were included into epoxy resin and then into self-cure acrylic resin. The patterns were cast in niquel-cromium alloy then luted with zinc phosphate cement (groups 1 and 3) or Panavia F (groups 2 and 4). Specimens were stored in 100% of relative humidity for 72 hours. Then, the posts were dislodged by traction forces. The recorded data was submitted to ANOVA. The values of the averages obtained in Kgf were: G1 - 21.744; G2 - 17.484; G3 - 25.229 e G4 - 20.028. There was no statistical significant difference between the groups (p<0.05). Disinfection and cleaning protocol for the post space preparation must be established and the 2% chlorhexidine gluconate in gel did not affect negatively the retention of the cast posts in this study. This data suggests that this is a good auxiliary substance in the post space preparation because it presents advantage features for the procedure as: low toxicity, easy handle, antimicrobial action and substantivity.
87

Hidróxido de cálcio associado à clorexidina - estudo em cultura de células (RAW 264.7 e cultura primária de células da linhagem osteoblástica) e em tecido subcutâneo de camundongos. Avaliação da atividade antimicrobiana / Calcium hydroxide associated to chlorhexidine - Study in cell culture (RAW 264.7 and primary cell culture of osteoblastic lineage), and in mice subcutaneous tissue. Evaluation of Antimicrobial Activity

Silva, Raquel Assed Bezerra da 05 November 2007 (has links)
O objetivo do presente estudo foi avaliar a pasta à base de hidróxido de cálcio (Calen®), associada ou não ao digluconato de clorexidina a 0,4%, em cultura de macrófagos da linhagem RAW 264.7, cultura primária de células da linhagem osteoblástica e em tecido subcutâneo de camundongos. Além disso, foi avaliada a atividade antimicrobiana desses materiais. Em cultura de macrófagos RAW 264.7 foram avaliados os seguintes aspectos: a viabilidade celular (Ensaio de MTT), propriedades imunoestimuladoras (dosagem de óxido nítrico) e propriedades antiinflamatórias (dosagem de óxido nítrico, TNF-&alpha; e IL-1&alpha;). Em cultura primária de células da linhagem osteoblástica foram avaliados viabilidade celular (períodos de 3, 7 e 10 dias), conteúdo de proteína total (Método de Lowry modificado nos períodos de 7 e 10 dias), atividade da fosfatase alcalina (liberação de timolftaleína nos períodos de 7 e 10 dias e in situ pelo método do Fast red), proteínas da matriz não-colágena (marcação por Imunofluorescência Indireta e Fluorescência Direta por meio da utilização da faloidina e DAPI, nos períodos de 3, 7 e 14 dias) e formações nodulares de matriz mineralizada (marcação pelo vermelho de Alizarina nos períodos de 3, 7 e 14 dias). A atividade antimicrobiana foi avaliada por meio do teste de difusão em ágar, sobre 2 microrganismos indicadores (Enterococcus faecalis e Kocuria rhizophila). A biocompatibilidade após implantanção de tubos de polietileno contendo as pastas no tecido subcutâneo de camundongos isogênicos Balb/c. Os dados numéricos foram submetidos à análise estatística por meio do teste de Kruskal-Wallis e pós-teste de Dunn, com nível de significância de 5%. Os resultados referentes à exposição das células da linhagem RAW 264.7 de macrófagos evidenciou baixa atividade imunoestimuladora da pasta à base de hidróxido de cálcio (Calen®), associada ou não ao digluconato de clorexidina 0,4%, nas diferentes concentrações avaliadas. Por outro lado, pôde-se observar atividade antiinflamatória, com inibição na liberação de óxido nítrico e das citocinas (TNF-&alpha; e IL1-&alpha;), quando da utilização da associação hidróxido de cálcio e clorexidina na concentração de 25&micro;g/ml. Resultados semelhantes ao controle foram observados após a avaliação da pasta à base de hidróxido de cálcio (Calen®), associada ou não ao digluconato de clorexidina a 0,4% em cultura primária de células da linhagem osteoblástica uma vez que os dados numéricos do conteúdo de proteína total, da quantidade de fosfatase alcalina e das formações nodulares de matriz mineralizada não foram estatisticamente diferentes (p>0,05). Em relação à caracterização morfológica das culturas primárias os resultados obtidos foram semelhantes quando comparou-se a pasta Calen®, associada ou não à clorexidina a 0,4%. Em relação à atividade antimicrobiana, a associação hidróxido de cálcio e clorexidina promoveu a formação de maiores halos de inibição (em mm), em relação ao Enterococcus faecalis, embora sem diferença estatística significante com os demais grupos avaliados (p>0,05). No tecido conjuntivo subcutâneo de camundongos, a análise microscópica demonstrou ser esta associação biocompatível, com tecido circunjacente e reacional, apresentando fibrosamento discreto e semelhante ao tecido conjuntivo fibroso normal, aos 63 dias de avaliação, sem diferença estatística com grupo controle (p>0,05). Com base nas metodologias empregadas e nos resultados obtidos pode-se concluir que a adição da clorexidina não apresentou benefícios adicionais à pasta à base de hidróxido de cálcio. / The aim of this study was to evaluate the calcium hydroxide-based paste (Calen®), associated or not to 0.4% chlorexidine digluconate, in culture of RAW 264.7 macrophages lineage, primary culture of osteoblastic lineage, and mice subcutaneous tissue. Besides we evaluated the antimicrobial activity of those materials. In RAW 264.7 macrophages culture the followed aspects were evaluated: cellular viability (MTT assay), immunestimulatory (nitric oxide detection) and anti-inflammatory (nitric oxide, TNF-&alpha; and IL-1-&alpha; detection) properties. In primary cell culture of osteoblastic lineage we evaluated the cellular viability for 3, 7 and 10 days, total protein content (Lowry modified method for 7 and 10 days), alkalinic phosphatase activity (thymolphthalein liberation for 7 and 10 days, and in situ by Fast red method), extracellular matrix noncollagen protein (stained by indirect immunofluorescence and direct fluorescence by phalloidin and DAPI for 3, 7 and 14 days), and mineralized matrix nodular formation (stained by Alizarin red for 3, 7 and 14 days). Antimicrobial activity was evaluated by agar diffusion test with Enterococcus faecalis and Kocuria rhizophila as indicators, and the biocompatibility after polyethylene tubes with the paste implanted into Balb/c mice subcutaneous tissue. The data were statistically analyzed by Kruskal-Wallis test, followed by Dunn\'s post test, considering a level of significance of 5%. The results of macrophage RAW 264.7 cells lineage exposition showed low stimullatory activity for the different concentrations evaluated of calcium hydroxide-based paste (Calen®), associated or not to 0.4% chlorexidine digluconate. On the other hand, we could observe anti-inflammatory activity with inhibition of nitric oxide and cytokines quantification (TNF--&alpha; e IL1--&alpha;), after the use of 25-&micro;g/ml calcium hydroxide associated to chlorhexidine (25-&micro;g/ml). Same results to the control were observed after evaluation of Calen® paste associated or not to 0.4% chlorexidine digluconate, in culture of RAW 264.7 macrophages lineage, primary culture of osteoblastic lineage because the data of total protein content, alkaline phosphatase, and mineralized matrix nodular formation were not statistically different (p>0.05). In relation to the morphological characterization of primary culture, the results obtained were the same after comparison of Calen® paste, associated or not to 0.4% chlorexidine digluconate. About antimicrobial activity, the association Calcium hydroxide and chlorhexidine promoted formation of largest inhibition halo (in mm) for Enterococcus faecalis, but with no statistically significant with others evaluated groups (p>0.05). The microscopic analysis in mice conjunctive subcutaneous tissue demonstrated biocompatibility of that association with the around and reactional tissue, sowing a discret fibrosis, as well as the normal conjunctive fibrous tissue after 63 days of evaluation with no statistically difference with the control group (p>0.05). Based on the methodology used, and the results obtained in this work, we could conclude that the addition of chlorexidine showed no additional benefits to the calcium hydroxide-based paste.
88

Avaliação do efeito antimicrobiano in vitro de quitosana e da associação quitosana/clorexidina sobre saliva e Streptococcus mutans / Evaluation of in vitro antimicrobial effect of chitosan and chitosan/chlorhexidine on saliva and Streptococcus mutans

Oliveira, Rosemary Aparecida de 11 November 2004 (has links)
Saliva e Streptococcus mutans foram utilizados neste estudo para avaliar a atividade antimicrobiana da quitosana associada à clorexidina. Os testes de atividade antimicrobiana foram realizados utilizando-se soluções de quitosana e quitosana:clorexidina preparadas em ácido acético 1%, em diversos valores de pH (3,5-5,0) e valores de concentração variando entre 0,1 e 1,5% (m/v). Antes de cada experimento o pH da solução estoque de quitosana (grau de desacetilação 76% e massa molar 400.000 g/mol) foi ajustado até o pH desejado pela adição de NaOH. A atividade antimicrobiana aumentou com o pH, com a concentração, com o tempo de exposição e com a associação quitosana/ clorexidina. Aumentando-se a concentração de clorexidina não se observam efeitos significativos, indicando que em presença de quitosana é possível liberar este composto em concentrações menores, o que irá minimizar os efeitos colaterais indesejados de pigmentação e sensação de alteração de sabor / Saliva and Streptococcus mutans were used to evaluate antimicrobial activity of chitosan/chlorexidine solutions. Antimicrobial tests were conducted using chitosan and chitosan/ chlorexidine solutions in 1.0 % acetic acid solution, at various pH values (3.5-5.0) and concentrations ranging from 0.1 to 1.5% (w/v). Prior to each experiment, chitosan (DA 76%, 400.000 g/mol) stock solution pH was adjusted to the desired pH using NaOH. The antimicrobial activity increased with pH, concentration, exposition time and with the association of chitosan and chlorexidine. Increasing the concentration of chlorexidine did not have a significant effect indicating that in presence of chitosan it is possible to deliver this compound at a lower concentration which will avoid unwanted side effects including staining and altered taste sensations
89

Estudo in vitro da influência da contaminação com Streptococcus mutans e da descontaminação com digluconato de clorexidina 2% na resistência de união de sistemas adesivos à dentina humana / In vitro study of the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on bond strength of adhesive systems to human dentin

Bengtson, Camilla Regina Galvao 21 June 2007 (has links)
O objetivo desse trabalho foi avaliar, in vitro, a influência da contaminação com Streptococcus mutans e da desinfecção com solução de digluconato de clorexidina 2% na adesão de dois sistemas adesivos (um sistema adesivo com condicionamento ácido prévio e um sistema adesivo autocondicionante) à dentina de molares humanos. Para o estudo, foram utilizados 80 terceiros molares humanos hígidos, com a face oclusal lixada até a exposição de uma superfície plana de dentina. Os dentes foram divididos aleatoriamente em 8 grupos (n=10) de acordo com o sistema adesivo utilizado e tratamento superficial realizado: G1 ? Controle Single Bond 2 (SB); G2 ? Controle Clearfil SE Bond (SE); G3 ? Desinfecção com clorexidina SB; G4 ? Desinfecção com clorexidina SE; G5 ? Contaminação com Streptococcus mutans SB; G6 ? Contaminação com Streptococcus mutans SE; G7 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SB e G8 ? Contaminação com Streptococcus mutans e desinfecção com clorexidina SE. Corpos de prova em resina composta foram confeccionados nas superfícies tratadas e os dentes foram armazenados em água destilada à 37ºC por 24 horas. As amostras foram seccionadas verticalmente obtendo-se espécimes com área de secção transversal de aproximadamente 0,8mm2, que foram tracionados a velocidade de 0,5mm/min em máquina de ensaios universal. Cinco espécimes de cada grupo tiveram a interface adesiva analisada em microscopia eletrônica de varredura (MEV). Os resultados de resistência de união foram analisados usando os testes estatísticos ANOVA e Tukey (p<0,05). Os modos de fraturas foram avaliados por meio de lupa esteroscópica (25X). Discos de dentina foram obtidos de 6 dentes adicionais, para observação em MEV das superfícies submetidos aos mesmos tratamentos realizados para o teste de microtração. Não foram encontradas diferenças estatísticas entre os grupos controles (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), o tratados com clorexidina (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) e os grupos que foram submetidos à contaminação com Streptococcus mutans e descontaminação com clorexidina (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). Os grupos submetidos à contaminação com Streptococcus mutans que não foram descontaminados antes da aplicação dos sistemas adesivos tiveram resultados significantemente menores que os grupos estéreis e descontaminados (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). O sistema adesivo Clearfil SE Bond apresentou valores de resistência de união significantemente maiores que o sistema adesivo Single Bond 2, independente do tratamento da superficial dentina. Pôde-se concluir que a contaminação in vitro com Streptococcus mutans comprometeu a adesão dos dois sistemas adesivos e a solução de digluconato de clorexidina 2% foi capaz de eliminar a contaminação, restabelecendo os valores de resistência de união obtidos com o substrato estéril. / The purpose of this study was to evaluate, in vitro, the influence of Streptococcus mutans contamination and 2% chlorhexidine digluconate disinfection on the bond strength of two adhesive systems (an etch-and-rinse system and a self-etch system) to human dentin molars. Flat dentinal surfaces were prepared in 80 extracted human third molars. Teeth were randomly divided into 8 groups (n=10) according to the adhesive system and the dentin superficial treatment: G1 ? Single Bond 2 (SB) control; G2 ? Clearfil SE Bond (SE) control; G3 ? Desinfection with chlorhexidine SB; G4 ? Desinfection with chlorhexidine SE; G5 ? Contamination with Streptococcus mutans SB; G6 ? Contamination with Streptococcus mutans SE; G7 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SB e G8 ? Contamination with Streptococcus mutans and desinfection with chlorhexidine SE. Composite resin blocks were built up over treated surfaces, and teeth were then stored in water at 37 degrees C for 24 h. Samples were vertically sectioned, obtaining specimens with 0.8mm2 cross-sectional area. Specimens were stressed in tension at 0.5 mm/min crosshead speed. Five specimens of which group were observed under SEM. Bond strength results were evaluated using ANOVA and Tukey tests(p<0.05). The modes of failures were verified using optical microscope (25X). Dentin disks were obtained from 6 additional teeth treated in the same manner for observation under SEM. No statistically significant differences of bond strength values were found between controls groups (G1 = 31,52 ± 6,24 e G2 = 42,88 ± 2,31), groups treated with chlorhexidine (G3 = 34,41 ± 6,92 e G4 = 40,14 ± 2,91) and groups contaminated with Streptococcus mutans (G7 = 31,12 ± 5,31 e G8 = 39,09 ± 3,86). The groups contaminated with Stretococcus mutans that were not desinfected before the adhesive systems application presented significantly lesser results than sterile or desinfected groups (G5 = 23,61 ± 7,13 e G6 = 33,15 ± 3,35). Clearfil SE Bond presented significant high bond strenght values than Single Bond 2, independent of dentin superficial treatment. It was concluded that the contamination in vitro with Streptococcus mutans reduced bond strength of the two adhesives systems and 2% chlorhexidine digluconate solution eliminated the contamination, reestablishing the bond strength values gotten with sterile substrates.
90

Formação de biofilme e corrosão em aparelhos disjuntores de Haas, com e sem utilização de agente antimicrobiano: estudo in situ / Biofilm formation and corrosion in Haas expanders, with and without use of an antimicrobial agent: in situ study.

Rossi, Cristhiane Ristum Bagatin 19 September 2007 (has links)
O objetivo do presente estudo foi avaliar, em aparelhos disjuntores de Haas, a contaminação in situ por estreptococos do grupo mutans, sob a forma de colônias/biofilmes, nas diferentes superfícies (acrílico, fios, bandas e parafusos), com e sem o uso de bochechos com gluconato de clorexidina a 0,12%, por meio de Cultura Microbiana e Microscopia Eletrônica de Varredura (MEV). Adicionalmente, a corrosão na área da união entre o fio, a solda de prata e a banda dos aparelhos foi avaliada por meio de Estereomicroscopia Ótica, MEV e análise em Espectrometria de Energia Dispersiva (EDS). Foram selecionados 34 pacientes de 7 a 12 anos de idade, que compareceram à clínica de Ortodontia Preventiva da FORP/USP, com necessidade de correção com aparelho disjuntor de Haas por problemas transversais da maxila (mordida cruzada posterior). Em seguida, utilizando uma tabela de números randômicos, os pacientes foram aleatoriamente divididos em dois grupos de 17 indivíduos cada (Grupos I e II). Durante todo o período de permanência dos aparelhos na cavidade bucal, no Grupo I (controle; n=17) os pacientes foram orientados a utilizar dentifrício fluoretado para escovação diária e não empregar bochechos com soluções antimicrobianas. Por outro lado, no Grupo II (experimental; n=17) os pacientes foram orientados a realizar, além da escovação diária com o uso de dentifrício fluoretado, 2 bochechos por semana com solução de gluconato de Clorexidina a 0,12% (Periogard®). Decorridos cerca de 4 meses da permanência na cavidade bucal, os aparelhos foram removidos. Sendo seccionadas, aleatoriamente, partes dos aparelhos constituídas de uma banda com fio soldado, para análise em estereomicroscopia ótica, MEV e EDS. Os resultados em estereomicroscopia foram submetidos à análise estatística por meio do teste de Fisher, com nível de significância de 5%. Em seguida, os aparelhos foram submetidos ao processamento microbiológico, em meio de cultura CaSa B, para contagem das colônias/biofilmes de estreptococos do grupo mutans. O teste estatístico não-paramétrico de Mann-Whitney foi aplicado para verificação de possíveis diferenças entre os grupos, com relação à formação de colônias/biofilmes sobre a superfície das diferentes áreas (parafuso, resina acrílica, bandas, fio vestibular e fio palatino), como também para verificar se havia diferença entre a formação de colônias/biofilmes sobre as superfícies livres (voltadas para a cavidade bucal) e as superfícies não-livres (em contato direto com a mucosa palatina e sulco gengival). O nível de significância adotado foi de 5%. Após cultura microbiana, partes dos aparelhos representativas de cada grupo foram submetidas ao processamento e análise em MEV. Os resultados obtidos evidenciaram que, com relação às colônias/biofilmes das superfícies nãolivres dos Grupos I e II, não houve diferença entre os grupos (p=0,009). No entanto, quando as superfícies livres dos Grupos I e II foram comparadas, evidenciou-se diferença significante entre os 2 grupos, em todas as áreas analisadas (parafuso, resina acrílica e bandas) (p<0,001). Os resultados da cultura microbiana foram confirmados em MEV. A análise em estereomicroscopia ótica evidenciou a presença de áreas de alteração de coloração sugestivas de corrosão na região de solda em contato com a banda e com o fio, em ambos os grupos (p=1). Os picos dos elementos químicos observados em EDS também foram semelhantes em ambos os grupos. Pôde-se concluir que o uso do gluconato de clorexidina a 0,12% (Periogard®), sob a forma de bochecho, apresentou eficácia na redução da formação de colônias/biofilmes nas superfícies livres dos aparelhos disjuntores de Haas, in situ, sem elevação nos níveis de corrosão. / The purpose of this study was to evaluate, in situ, in Haas expanders, the contamination of different surfaces (acrylic resin, wires, bands and screws) by mutans group streptococci colonies/biofilms with and without prescription of 0.12% chlorhexidine gluconate mouthwashes, by means of microbial culture and scanning electron microscopy (SEM). Additionally, the corrosion in the area of union between the appliances wire, silver soldering and band was assessed by optical stereomicroscopy, SEM and energy dispersive spectroscopy (EDS). Thirty-four children aged 7 to 12 years were selected among the patients attending the Preventive Orthodontic Clinic at FORP/USP with need of corrective orthodontics with Haas expander due to transversal problems of the maxilla (posterior crossbite). Thereafter, using a table of random numbers, the patients were randomly assigned to two groups of 17 individuals each (Groups I and II). Throughout the time that the appliances remained in the oral cavity, the patients in Group I (control; n=17) were instructed to use a fluoridated dentifrice for daily toothbrushing and not to use antimicrobial mouthwash solutions. On the other hand, in Group II (experimental; n=17), in addition to daily toothbrushing with a fluoridated dentifrice, mouthwashes with an antimicrobial agent (0.12% chlorhexidine gluconate - Periogard®) were prescribed to the patients. After approximately 4 months of maintenance in the patients mouth, the appliances were retrieved. Thereafter, components of the appliances (consisting of a band with soldered wire) were sectioned at random for analysis under optical stereomicroscopy, SEM and EDS. The results of the optical stereomicroscopy were submitted to statistical analysis using Fisher\'s test at 5% significance level. The appliances were sent to microbiology processing, in CaSa B culture medium, for counting of the number of mutans streptococci colonies/biofilms. Mann-Whitney non-parametric statistical test was applied to verify possible differences between the groups with respect to the formation of colonies/biofilms on the surface of different areas (screw, acrylic resin, bands, buccal wire and palatal wire), as well as to determine whether there were differences between the formation of colonies/biofilms on free surfaces (facing the oral cavity) and non-free surfaces (in direct contact with the palatal mucosa and gingival sulcus). The level of significance was set at 5%. After microbial culture, components of the appliances that were representative of each group were submitted technical processing and SEM analysis. The obtained results showed that there was no statistically significant difference between Groups I and II (p=0.009) regarding the formation of colonies/biofilms on the non-free surfaces. However, when the free surfaces of Groups I and II were compared, statistically significant difference was observed between these groups in all analyzed areas (screw, acrylic resin and bands) (p<0.001). The results of the microbial culture were confirmed by the SEM analysis. The optical stereomicroscopic analysis showed the existence of color alteration suggestive of corrosion in the solder region in contact with the band and with the wire in both groups (p=1). The peaks of chemical elements observed in EDS were also similar in both groups. It may concluded that the use of 0.12% chlorhexidine gluconate mouthwashes (Periogard®) showed efficacy in reducing the formation of colonies/biofilms on the free surfaces of Haas expanders, in situ, without increasing the corrosion levels.

Page generated in 0.0636 seconds