• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • Tagged with
  • 45
  • 45
  • 45
  • 12
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação de fios de Polipropileno comerciais para sutura visando a construção de um processo de certificação sanitária. / Evaluation of commercial polypropylene yarn for suture aiming the construction of a sanitary certification process.

NASCIMENTO, Alessandro Ferreira do. 05 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-05T19:25:23Z No. of bitstreams: 1 ALESSANDRO FERREIRA DO NASCIMENTO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1766148 bytes, checksum: 9952d3c1d40fa2b65189b5ac5fa3540f (MD5) / Made available in DSpace on 2018-04-05T19:25:23Z (GMT). No. of bitstreams: 1 ALESSANDRO FERREIRA DO NASCIMENTO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1766148 bytes, checksum: 9952d3c1d40fa2b65189b5ac5fa3540f (MD5) Previous issue date: 24-07-16 / Os fios para sutura cirúrgica são considerados produtos médicos invasivos utilizados para aproximação de tecido biológico e, devido ao contato com a pele, vasculatura e outros tecidos, são considerados um produto crítico. O presente trabalho propõe a avaliação de um dos fios com maior número de queixas técnicas notificadas à ANVISA, o fio de sutura de polipropileno, que é empregado em diversas intervenções cirúrgicas que requerem material inerte ao tecido e suporte mecânico, assim, uma avaliação da natureza físico-química do material empregado em amostras comerciais é importante para nortear um processo de certificação sanitária visando minimizar o risco aos pacientes. O fio de polipropileno foi adotado como modelo de análise , sendo escolhido o fio de número cirúrgico 0(zero) com 75cm de comprimento; foram selecionadas 4 amostras de fios de sutura de polipropileno de acordo com o padrão de notificações recebidas pela área de tecnovigilância da ANVISA como modelo para a execução de ensaios de difração de raio X, microscopia ótica, microscopia eletrônica de varredura com mapeamento por EDS, FTIR, microscopia de força atômica, análise termogravimétrica e ensaios mecânicos. Os resultados apresentados demonstraram perfis distintos nos aspectos morfológicos e mecânicos dos fios de sutura selecionados, suscitando a construção de um conjunto de análises distintas daquelas atualmente preconizadas para o registro desses produtos, assim como o estabelecimento de um processo certificador que seria realizado harmonizando parâmetros de ensaios mecânicos e caracterização morfológica dos fios de sutura, capaz de assegurar maior homogeneidade nos fios de sutura disponíveis comercialmente. / The suture threads are considered invasive medical products used for approximation of biological tissue and, due to contact with the skin, vasculature and other tissues, are considered a critical product. This paper proposes an evaluation of one of the wires with the largest number of technical complaints notified to ANVISA, the suture of polypropylene, which is used in various surgical procedures which require inert mechanical support to the tissue and thus a substantive assessment of the nature physical chemistry of the material used in commercial samples is important to guide a process of health certification in order to minimize the risk to patients. The polypropylene suture was used as the analysis model, being selected the surgical wire number 0 (zero) to 75cm long; 4 samples of polypropylene sutures were selected according to the pattern of notifications received by the area of technical surveillance of ANVISA as a model for the implementation of the testing of X-ray diffraction, optical microscopy, scanning with EDS mapping by electron microscopy, FTIR, atomic force microscopy, thermal analysis and mechanical testing. The results presented demonstrated distinct profiles on the morphological and mechanical suture wires of selected aspects, prompting the construction of a set of analyzes of those currently recommended for the registration of these products, as well as the establishment of a certification process that would be done by harmonizing testing parameters morphological and mechanical characterization of the suture capable of ensuring a greater homogeneity in the commercially available suture threads.
42

Análise da degradação e do poder calorífico de resíduos sólidos urbanos. / Analyse de la dégradation et du pouvoir calorifique des déchets dans les solides urbains. / Analysis of the degradation and calorific power of waste to urban solids (garbage) / Análisis de la degradación y del poder calorífico de residuos sólidos urbanos.

QUEIROZ, Abílio José Procópio. 06 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-06T21:19:15Z No. of bitstreams: 1 ABÍLIO JOSÉ PROCÓPIO QUEIROZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 5068589 bytes, checksum: 8bb50d0449bc510a3c3f1cd6c496edd3 (MD5) / Made available in DSpace on 2018-04-06T21:19:15Z (GMT). No. of bitstreams: 1 ABÍLIO JOSÉ PROCÓPIO QUEIROZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 5068589 bytes, checksum: 8bb50d0449bc510a3c3f1cd6c496edd3 (MD5) Previous issue date: 2014-08-27 / O gerenciamento de resíduos sólidos urbanos, atualmente feito de forma errônea na maior parte das cidades brasileiras, acelerando a degradação do meio ambiente, e a busca por fontes alternativas de energia, para suprimento da crescente demanda, são problemáticas atualmente discutidas e que precisam de soluções urgentes. Este estudo identifica características físicoquímicas de RSU, depositados em biorreator que simula as condições de um aterro sanitário, e avalia a possibilidade de utilização de um material que ainda é descartado como combustível para geração de energia. O objetivo geral foi avaliar a degradação e o poder calorífico de resíduos sólidos urbanos. As amostras analisadas por FTIR, DRX, TG e DSC foram coletadas em lisímetro construído na Universidade Federal de Campina Grande e preenchido de RSU previamente caracterizados. Os ensaios de FTIR indicaram a predominância orgânica dos materiais presentes nas amostras de RSU. Pelos difratogramas de raios-X o principal pico e comum a todas amostras foi de quartzo, justificando a presença do solo de recobrimento das amostras. As amostras de RSU apresentaram baixa estabilidade térmica, ocorrendo degradação entre a temperatura ambiente e 1000 ºC, sendo visível e aceitável afirmar que ocorrem em cinco etapas de perda associadas à volatilização dos solventes (água e álcoois), à queima de celulose, borracha natural, matéria orgânica putrescível e materiais plásticos, bem como dos óxidos formados durante o processo. Pelas curvas DSC foram identificadas uma reação endotérmica, associada à primeira perda de massa, e quatro reações, duas endotérmicas e duas exotérmicas, ligadas às perdas da degradação dos componentes orgânicos. Os 348.402 kg/dia de RSU produzidos em Campina Grande, amostrados pela massa do biorreator, possuem um poder calorífico médio de 3.744,86 kcal/kg e poderiam ser gerados 1.518.551,40 kW.h/dia de energia térmica ou 303.710,28 kW.h/dia de energia elétrica, com eficiência de conversão de 20%. / The management of municipal solid waste, currently done wrongly in most Brazilian cities, accelerating the degradation of the environment, and the search for alternative energy sources to supply the growing demand, are currently discussed and problems that need solutions urgent. This study identifies physical and chemical characteristics of MSW deposited in bioreactor that simulates the conditions of a landfill site, and evaluates the possibility of using a material that is still dismissed as fuel for power generation. The overall objective was to evaluate the degradation and the calorific value of municipal solid waste. The samples analyzed by FTIR, XRD, TG and DSC were collected in lysimeter constructed at the Federal University of Campina Grande and filled MSW previously characterized. FTIR tests indicated a predominance of the organic materials present in samples of MSW. By X-ray diffraction main peak and common to all samples was quartz, which explains the presence of the soil cover of the samples. MSW samples had poor thermal stability, degradation occurring between room temperature and 1000 ºC, being visible and acceptable state that occurs in five steps loss associated volatilization of the solvents (water and alcohol), the combustion of cellulose, natural rubber, putrescible organic matter and plastics, as well as the oxides formed during the process. DSC curves for an endothermic reaction associated with the first weight loss and four reactions, two endothermic and exothermic two linked to the loss of the degradation of the organic components have been identified. The 348,402 kg/day of USW produced in Campina Grande, sampled by mass of the bioreactor have an average calorific value of 3,744.86 kcal/kg, and could be generated 1,518,551.40 kW.h/day of thermal energy or 303,710. 28 kW.h/day of electricity, with conversion efficiency of 20%.
43

Avaliação de implantes de polimetilmetacrilato (PMMA) para procedimentos de bioplastia. / Evaluation of polymethylmethacrylate implants for bioplasty procedures. / Evaluación de los implantes de polimetilmetacrilato para procedimientos de bioplastia. / Évaluation des implants de polyméthylméthacrylate pour les procédures de bioplastie.

DOLGHI, Sandro Martins. 09 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-09T18:16:27Z No. of bitstreams: 1 SANDRO MARTINS DOLGHI - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1349252 bytes, checksum: 7e20e2840dc2a5d2e873cd9b77ed0100 (MD5) / Made available in DSpace on 2018-04-09T18:16:27Z (GMT). No. of bitstreams: 1 SANDRO MARTINS DOLGHI - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1349252 bytes, checksum: 7e20e2840dc2a5d2e873cd9b77ed0100 (MD5) Previous issue date: 2014-12-19 / O culto à beleza está em evidência no Brasil e no mundo, levando ao crescente aumento de técnicas e procedimentos para corrigir defeitos estéticos e minimizar os efeitos do envelhecimento. Diversas substâncias preenchedoras com fluidos de alta viscosidade ou partículas de polímeros em suspensão têm sido utilizadas em larga escala em procedimentos cosméticos e correção de lipodistrofia de pacientes HIV positivos, submetidos à terapia antirretroviral de alta atividade. O uso de polimetilmetacrilato (PMMA) como substância de preenchimento dérmico tem crescido vertiginosamente, assim como o número de reações adversas decorrentes de seu uso. O PMMA vem sendo utilizado, amplamente como matéria prima na fabricação de diversos dispositivos e produtos médicos desde a década de 40, especialmente em função de sua biocompatibilidade, entretanto, ainda há carência de informações e estudos sobre migração e resposta inflamatória das substâncias comercializadas no Brasil para fins de preenchimento dérmico. Este trabalho teve como objetivo avaliar as características físico-químicas de implantes de PMMA comercializados no Brasil para procedimentos de bioplastia, em três apresentações comerciais do produto com diferentes concentrações, visando delimitar limites aceitáveis para fins de registro destes produtos na Agência Nacional de Vigilância Sanitária (Anvisa), com foco na segurança sanitária. As amostras foram caracterizadas por Difração de Raios X (DRX), Espectroscopia na região do infravermelho com transformada de Fourier (FTIR), Microscopia Eletrônica de Varredura (MEV), Espectroscopia por Energia Dispersiva de Raios X (EDS), análise de Calorimetria Exploratória Diferencial (DSC), caracterização por Microscopia Óptica (MO). A técnica de DRX mostrou comportamento semicristalino do PMMA. Com a técnica de FTIR constatou-se os grupos funcionais presentes nos implantes. Por meio das técnicas de MO e MEV foi possível perceber a não homogeneidade em relação ao tamanho das microesferas de PMMA. Pôde-se concluir com os resultados de DSC que o pico endotérmico aumentou de acordo com as variações de concentração do PMMA. A partir dos dados obtidos neste trabalho constata-se que o consumidor está sujeito a riscos, visto que a irregularidade das superfícies e variações nos tamanhos das microesferas pode ocasionar reações adversas, em função da fagocitose das microesferas com tamanho inferior a 20 μm. O crescente uso das técnicas de preenchimento com implantes de PMMA, bem como sua indicação para uso em demais especialidades da medicina, o coloca como material a ser ainda amplamente estudado nas mais diversas aplicações do produto na área médica. / The cult of beauty is in evidence in Brazil and in the world, leading to increasing techniques and procedures to correct aesthetic defects and minimize the effects of aging. Several dermal fillers with high viscosity or polymer particles in suspension fluids have been used in large scale in cosmetic procedures and lipodystrophy correction of HIV-positive patients undergoing HAART activity. The use of polymethylmethacrylate (PMMA) as dermal filler substance has grown dramatically, and the number of adverse reactions arising from its use. PMMA has been used widely as a raw material in manufacturing various medical devices and products since the 40s, especially due to its biocompatibility, however, there is still a lack of information and studies on migration and inflammatory response of substances marketed in Brazil dermal filler purposes. This study aimed to evaluate the physical and chemical characteristics of PMMA implants sold in Brazil for bioplasty procedures in three commercial presentations of the product with different concentrations, in order to delimit acceptable limits for registration of these products at ANVISA, with focus on security health. The samples were characterized by X-ray Diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Spectroscopy Energy Dispersive X-ray (EDS) analysis of Differential Scanning Calorimetry (DSC), characterized by Optical Microscopy (OM). The XRD technique showed semi-crystalline behavior of PMMA. FTIR technique found the functional groups present on the implants. Through OM and SEM techniques we saw the inhomogeneity relative to the size of the PMMA microspheres. One can conclude from the results of the DSC endothermic peak increased in accordance with changes in the concentration of PMMA. From the data obtained in this study it appears that the consumer is subject to risks as uneven surfaces and variations in size of the microspheres can cause adverse reactions, depending on the phagocytosis of microspheres with size less than 20 microns. The increasing use of technical fill with PMMA implants, as well as indications for use in other specialties of medicine, places it as material to be still widely studied in various product applications in the medical field.
44

Influência da Poli (Ɛ-Caprolactona) e de copolímeros funcionalizados no desempenho de blendas com matriz de poli (ácido-lático). / Influence of poly (Ɛ-caprolactone) and functionalized copolymers on the performance of poly (lactic acid) matrix blends. / Influence du poly (Ɛ-caprolactone) et des copolymères fonctionnalisés sur la performance des mélanges de matrices poly (acide lactique). / Influencia de la Poli (Ɛ-Caprolactona) y de copolímeros funcionalizados en el desempeño de mezclas con matriz de poli (ácido-láctico).

SILVA, Taciana Regina de Gouveia. 06 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-06T20:12:23Z No. of bitstreams: 1 TACIANA REGINA DE GOUVEIA - TESE PPG-CEMat 2014..pdf: 4953603 bytes, checksum: ea581c261908041111cd0d411a551545 (MD5) / Made available in DSpace on 2018-04-06T20:12:23Z (GMT). No. of bitstreams: 1 TACIANA REGINA DE GOUVEIA - TESE PPG-CEMat 2014..pdf: 4953603 bytes, checksum: ea581c261908041111cd0d411a551545 (MD5) Previous issue date: 2014-08-28 / Capes / Os polímeros derivados do petróleo têm provocado impactos ambientais devido ao descarte inadequado. Uma alternativa para esse problema é a utilização de polímeros biodegradáveis ou a produção de blendas a partir destes polímeros. Neste trabalho, foram preparadas blendas de poli (ácido lático) - PLA, poli (caprolactona) - PCL, com três copolímeros diferentes: EMA, E-GMA e o EMAGMA que são copolímeros de etileno-acrilato de metila, etileno-metacrilato de glicidila e o terpolímero etileno-acrilato de metila-metacrilato de glicidila, respectivamente. As composições utilizadas para as blendas foram as seguintes: PLA/PCL (90/10), PLA/PCL (80/20), PLA/Copolímeros (90/10) e PLA/PCL/Copolímeros (80/10/10). Estas foram preparadas por fusão em uma extrusora de rosca dupla corrotativa e, em seguida, moldadas por injeção sob a forma de corpos de prova de tração, impacto e HDT. Todas as composições foram caracterizadas por: ensaios mecânicos de tração e impacto, temperatura de distorção térmica - HDT, calorimetria exploratória diferencial - DSC, difração de raios X - DRX, análise térmica dinâmica-mecânica - DMTA, espectroscopia na região do infravermelho por transformada de Fourier - FTIR, microscopia eletrônica de varredura - MEV, reometria de torque, ensaio reológico e reometria capilar. As propriedades mecânicas apresentaram redução nos valores do módulo e da resistência à tração e um aumento no alongamento e na resistência ao impacto para todas as composições quando comparadas com o PLA puro, com destaque para as composições que continham o copolímero EMA-GMA. A HDT não apresentou mudanças significativas para as diferentes composições em comparação com o PLA puro. O comportamento térmico e termomecânico foi avaliado por DSC e por DMTA e foi possível observar a transição térmica das blendas. Por DRX foi possível observar as fases cristalinas das blendas de PLA. A morfologia da superfície de fratura observada por MEV ilustrou que ocorreram mudanças significativas em função da composição. Os resultados de reometria de torque não apresentaram mudanças significativas no comportamento do PLA, enquanto que os resultados obtidos no ensaio reológico ilustraram aumento no módulo de armazenamento em todas as composições. A partir do ensaio de reometria capilar foi visto que houve redução da viscosidade aparente e da tensão de cisalhamento sob altas taxas de cisalhamento para todas as composições. / The polymers derived from petroleum have caused environmental impacts due to improper disposal. An alternative to this problem is the use of biodegradable polymers or blends production from these polymers. In this work, blends of poly (lactic acid) - PLA, poly (-caprolactone) - PCL, were prepared with three different copolymers: EMA, E-GMA and EMA-GMA are copolymers the ethylene-methyl acrylate, ethylene-glycidyl methacrylate and terpolymer ethylene-methyl acrylate-glycidyl methacrylate respectively. The compositions used in the blends were as follows: PLA/PCL (90/10) PLA/PCL (80/20) PLA/ Copolymer (90/10) and PLA/PCL/Copolymer (80/10/10). These were prepared by melting in an extruder twin screw co-rotating and then injection molded in the form of specimens tensile, impact and HDT. All compositions were characterized by: mechanical tensile and impact , heat distortion temperature - HDT, differential scanning calorimetry - DSC, X-ray diffraction - XRD, dynamic mechanical thermal analysis – DMTA, spectroscopy in the infrared region by transform Fourier - FTIR, scanning electron microscopy - SEM, torque rheometer, rheological testing and capillary rheometer. The mechanical properties showed reduced values of modulus and tensile strength and an increase in elongation and impact resistance for all compositions when compared with pure PLA, especially for compositions containing copolymer EMA-GMA. The HDT showed no significant changes for the different compositions compared with pure PLA. The thermal and thermomechanical behavior was evaluated by DSC and DMTA and it was possible to observe the thermal transition of the blends. XRD was possible to observe the crystalline phases of the blends of PLA. The morphology of the fracture surface was observed by SEM illustrated that significant changes as a function of composition. The torque rheometer results showed no significant change in the behavior of PLA, while the rheological test results illustrate the increase in storage modulus in all compositions. From the test capillary rheometer was seen that there was a reduction in the apparent viscosity and shear stress at high shear rates for all compositions.
45

Avaliação das características fisico-químicas de géis de fluor de uso odontológico profissional. / Evaluation of the physicochemical characteristics of fluoride gels for professional dental use. / Evaluación de las características fisicoquímicas de geles de fluor de uso odontológico profesional. / Évaluation des caractéristiques physico-chimiques des gels fluorés à usage dentaire professionnel.

CARDOSO, Gina Maria Coelho de Souza. 05 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-05T19:46:22Z No. of bitstreams: 1 GINA MARA COELHO DE SOUZA CARDOSO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1501065 bytes, checksum: e02311753867e448c8a544a0dd42857f (MD5) / Made available in DSpace on 2018-04-05T19:46:22Z (GMT). No. of bitstreams: 1 GINA MARA COELHO DE SOUZA CARDOSO - DISSERTAÇÃO PPG-CEMat 2014..pdf: 1501065 bytes, checksum: e02311753867e448c8a544a0dd42857f (MD5) Previous issue date: 2014-07-17 / O uso clínico de géis de flúor para aplicação tópica por profissionais está indicado para prevenção e tratamento de cárie e erosão dental devido à capacidade de interação com o processo de desmineralização-remineralização da matriz mineral do dente. O objetivo geral deste trabalho foi avaliar géis com flúor para remineralização dentária de uso tópico profissional quanto às características físico-químicas especificadas nos registros concedidos pela ANVISA. Foi verificada a existência de quinze (15) registros válidos na ANVISA, referentes a dezesseis (16) produtos de gel com flúor de uso tópico odontológico. Quanto a estes produtos, são oito (8) géis de flúor neutro e oito (8) géis de flúor acidulado. Todos os produtos possuem em sua composição fluoreto de sódio e o polímero mais utilizado para formação do gel é hidroxietil celulose, conforme declarado nos processos de registro na ANVISA. Em 60% dos processos de registro válidos há informação sobre o pH dos produtos. Com o levantamento realizado em março de 2014 nas dentais do Distrito Federal (DF), verificou-se a comercialização de dois produtos de um mesmo fabricante, sendo um gel de flúor neutro e um gel de flúor acidulado. Para a caracterização físico-química, foram adquiridos nove frascos de 200 mL de gel de flúor comercializados no DF: três de gel de flúor acidulado dentro da validade, três de gel flúor acidulado fora da validade e três de gel de flúor neutro. Estes produtos foram avaliados pelas seguintes técnicas: Microscopia eletrônica de varredura (MEV), Espectroscopia de energia dispersiva de raios X (EDS), espectroscopia na região de infravermelho com transformada de Fourier (FTIR), calorimetria exploratória diferencial (DSC), análise termogravimétrica (TGA) e avaliação do potencial hidrogeniônico (pH). Os elementos químicos identificados na análise por EDS estão condizentes com a composição química dos produtos declarados pelo fabricante à ANVISA. Os resultados de FTIR não demonstraram alterações significativas entre as amostras avaliadas. Foram verificados resultados diferentes entre as amostras, nos ensaios de TGA e DSC, isto provavelmente está relacionado com a desidratação das amostras e a formação de aglomerados. Os produtos avaliados a 25°C apresentaram resultados satisfatórios quanto ao pH. Mais pesquisas sobre a caracterização físico-química para o gel de flúor tópico de uso profissional odontológico são necessárias para embasar o desenvolvimento de normas técnicas específicas. / Clinical use of fluoride gels for topical application by professionals is indicated for prevention and treatment of dental caries and dental erosion due to the ability to interact with the process of demineralization - remineralization of tooth mineral matrix. The general objective of this work was to evaluate the physicochemical characteristics of topical gels for professional dental remineralization specified in the records granted by ANVISA. There were fifteen (15) valid records, relating to sixteen (16) products of fluoride gel use dental topic has been verified. As for these products, there were eight (8) neutral fluoride gels and eight (8) acidulated fluoride gels. All products contain in their composition sodium fluoride and the most used polymer for gel formation is hydroxyethyl cellulose. All acidulated fluoride gels have in their composition 1.23 % fluorine ions and all neutral fluoride gels contain 2 % NaF in its composition, as stated in the registration process at ANVISA. In 60 % of valid registration process there was information about the pH of the product. In the survey conducted in March 2014 in dental stores at Federal District (DF), it was observed the marketing of two products from the same manufacturer, being one neutral fluoride gel and one gel of acidulated fluoride. For physicochemical characterization, nine bottles of 200 ml of fluoride gel were acquired in DF: three of acidulated fluoride gel within the validity, three of acidulated fluoride gel out of date and three of neutral fluoride gel. These products were evaluated by the following techniques: Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectrometry (EDS), Fourier Transform Infrared Spectrometer (FTIR), Differential Scanning Calorimetry (DSC), Thermogravimetry (TG) and evaluation of the hydrogen potential (pH). The chemical elements identified by EDS analysis, in regions without clusters and with clusters of dehydrated samples, are consistent with the chemical composition of the products declared by the manufacturer to ANVISA. The FTIR outcomes showed no significant changes among analyzed samples. Different results among samples were observed during DSC and TGA tests, this is probably related to dehydration of the samples and the formation of agglomerates. More studies about the physicochemical characteristics of topical gels for professional dental remineralization are needed to support the development of specific technical standards.

Page generated in 0.1344 seconds