• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • Tagged with
  • 52
  • 52
  • 52
  • 45
  • 44
  • 30
  • 16
  • 15
  • 15
  • 14
  • 13
  • 13
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação das propriedades antimicrobianas, mecânicas e adesivas de cimentos de ionômeros de vidro empregados no tratamento restaurador atraumático / Evaluation of antimicrobial, mechanical and adhesive properties of glass ionomer cements used in atraumatic restorative treatment

Méndez- Bauer, María Luján 23 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-07-31T13:38:36Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) MARÍA LUJÁN MÉNDEZ BAUER.pdf: 12902846 bytes, checksum: 801f717d7497117a7c090a250c895f0e (MD5) / Made available in DSpace on 2018-07-31T13:38:36Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) MARÍA LUJÁN MÉNDEZ BAUER.pdf: 12902846 bytes, checksum: 801f717d7497117a7c090a250c895f0e (MD5) Previous issue date: 2018-02-23 / Este estudo avaliou in vitro as propriedades antimicrobianas, mecânicas e adesivas de cimentos de ionômero de vidro (CIVs) que podem ser utilizados no Tratamento Restaurador Atraumático. Os CIVs Ketac-Molar, Ion-Z, Vitro-Molar e Fuji-IX foram submetidos aos testes de difusão em ágar (DA), aderência bacteriana (AB), abrasão (Ab), erosão (Er), sorção e solubilidade (SO-SB), expansão hidroscópica (EH), resistência flexural (RF), microinfiltração (MI) e microcisalhamento (MS). Para DA foram feitos 4 poços em placas petri com S. mutans e foram preenchidos com os CIVs. A zona de inibição foi medida. Para AB cinco corpos de prova (CP) de cada CIV foram inoculados em caldo BHI com S. mutans. Depois os CP foram lavados em PBS para fazer duas diluições que foram semeadas em placas petri para contagem das UFC/ml. Para Ab, 40 CP foram submetidos aos ciclos de escovação simulada, avaliando-se massa, rugosidade e dureza. Para Er, 80 CP foram analisados quanto à rugosidade, massa e microdureza, após ciclo erosivo com três bebidas ácidas. Para SO-SB 40 CP tiveram suas massas avaliadas durante 56 dias. Para EH, 40 cilindros de vidro foram preenchidos com os CIVs e avaliados por 4 semanas. Para RF cada CIV foi testado em três pontos no ensaio de flexão. Para MI, 80 dentes foram restaurados e submetidos a termociclagem para avaliação de microinfiltração em superfície oclusal e cervical. Para MS 80 dentes foram restaurados com cilindros feitos dos CIVs e avaliados numa máquina universal de ensaios. Os dados foram analisados com o teste de Tukey (p ≥ 0.05). Nos resultados do teste DA, Ion-Z mostrou a maior atividade antimicrobiana nos tempos avaliados. Em AB, Fuji-IX apresentou a maior aderência. Em Ab os CIVs não apresentaram diferenças significativas na massa e microdurezaapós escovação; em rugosidade, o Ion-Z foi afetado pela escovação. Em Er, os CIVs não foram afetados pelas bebidas ácidas quanto à massa, no entanto, os valores de microdureza e rugosidade sofreram alterações. Em SO-SB, Ion-Z teve os maiores valores. Em EH, Vitro-Molar e Ion-Z apresentaram expansão hidroscópica. Em RF, Fuji-IX teve o maior valor, sem diferença significativa com Ketac-Molar e Ion-Z. Em MI, Fuji-IX teve menos infiltração em permanentes e em decíduos e os outros CIVs não tiveram diferenças significativas. Em MS, Ketac-Molar, Ion-Z e Fuji-IX apresentaram os melhores valores sem diferenças significantes; as fraturas adesivas foram as de maior ocorrência. O estudo concluiu que Ketac-Molar, Fuji-IX e Ion-Z apresentaram resultados similares. O Ion-Z é mais uma opção para restaurações ART, no entanto, estudos in vivo devem ser realizados. / This study evaluated in vitro the antimicrobial, mechanical and adhesive properties of glass ionomer cements used in the Atraumatic Restoration Treatment. The glass ionomer cements (GIC) Ketac-Molar, Ion-Z, Vitro-Molar and Fuji-IX were evaluated in agar diffusion test (AD), bacterial adhesion (BA), abrasion (Ab), erosion (Er), water sorption and solubility (WS-SB), hygroscopic expansion (HE), flexural strength (FS), microleakage (ML), and micro-shear (MS). For AD 4 wells were filled with the GICs in petri dishes with S. mutans. The zone of inhibition was measured. For BA five specimens of each GIC were inoculated into BHI broth with S. mutans. Then the specimens were washed with PBS and after, the PBS were diluted twice to then seeded into petri dishes and the UFC/ml was counted. For Ab, 40 specimens were submitted to simulated brush cycles, evaluating mass, roughness and hardness. For Er 80 specimens were analyzed by roughness, mass and microhardness, according to the erosive cycle with acidic beverages. For WS-SB 40 specimens were evaluated according to mass for 56 days. For HE, 40 glass cylinders were filled with GICs and evaluated for 4 weeks. For FS each CIV was tested in the three-point bending test. For ML, 80 teeth were restored and submitted to thermocycling for evaluation of microleakage. For MS 80 teeth were sectioned and placed in PVC tubes. The specimens were restored with cylinders made of the GIC and evaluated in a universal testing machine. Data were analyzed using the Tukey test (p ≥ 0.05). In AD results, Ion-Z showed the highest antimicrobial activity in each evaluated time. In AB, Fuji-IX presented the highest bacterial adhesion. In Ab the GICs did not present significant difference after brushing in mass and microhardness; in roughness, Ion-Z was affected. In Er, the GICs were not affected by the acidic beverages in mass, however, the results of microhardness and roughness have changes. In SO-SB, Ion-Z had the highest values. In HE, Vitro-Molar and Ion-Z presented hydroscopic expansion. In RF, Fuji-IX had the highest value, without significant difference with Ketac-Molar and Ion- Z. In IM, Fuji-IX had less infiltration in permanent and in deciduous teeth; the others GICs didn´t have significant differences. In MS, Ketac-Molar, Ion-Z and Fuji-IX presented the best values without significant differences; the adhesive fractures were the ones with highest percentage. The study concluded that Ketac-Molar, Fuji-IX and Ion-Z presented similar results. Ion-Z is another option for ART restorations, however, in vivo studies should be performed. Keywords: glass ionomer cements, atraumatic restorative treatment, antimicrobial properties, mechanical properties, adhesive properties
32

Influência da aceleração de presa por meio de ultrassom, luz halógena e diodo emissor de luz nas propriedades e resistência de união à dentina de cimentos de iônomero de vidro / Influence of accelaration setting reaction by ultrasound, halogen light and light emitted diode on properties and bond strength of glass ionomer cement

Yoshioka, Laysa 17 February 2016 (has links)
Este estudo avaliou a influência da aceleração de presa de cimentos de ionômero de vidro de alta viscosidade (CIVAV) por meio de ultrassom, luz halógena e diodo emissor de luz (LED). Para as análises, os espécimes foram divididos em nove grupos de acordo com o material - CIVAV versão pó-líquido (Fuji Gold Label IX GPGC Corp.), CIVAV versão encapsulado (Equia Fill - GC Corp.) e a aceleração de presa inicial - controle negativo; aplicação de ultrassom por 20s, irradiados com luz halógena por 60s, irradiados com LED por 60s, além de um grupo controle positivo de cimento de ionômero de vidro modificado por resina (CIVMR) versão pó-líquido (Fuji II LC - GC Corp.). Para o teste de resistência flexural (RF) foram preparados 90 espécimes (25x2x2mm) (n=10), após armazenamento em água destilada por 24h a 37°C, os espécimes foram submetidos ao teste de RF de três pontos (1mm/min). Para a análise de rugosidade superficial (RS), 45 espécimes (n=5) previamente preparados para o teste de RF, foram selecionados aleatoriamente em cada grupo. A medida da RS (parâmetros Sa e Ra) do corpo de prova foi dada pela média de 5 leituras realizadas na superfície. Para o teste de resistência de união (RU), 90 molares decíduos (n=10) foram selecionados e cânulas de polietileno foram posicionadas sobre as superfícies planas de dentina pré-tratadas, preenchidas por um dos CIV e aplicado um dos aceleradores de presa de acordo com o grupo experimental. Após armazenamento em água destilada por 24h a 37°C, os espécimes foram submetidos ao teste de microcisalhamento (1,0 mm/min). O padrão de fratura foi analisado em microscópio esteroscópico (400 X). Para avaliar a interação dentina-CIV, foram selecionados 27 caninos decíduos (n=3), foi preparada uma cavidade (4x2x2mm) na superfície vestibular, então a cavidade foi restaurada com um dos CIV propostos pelo estudo para então ser aplicado um dos aceleradores de presa de acordo com o grupo experimental. Após armazenados por 48h a 37ºC e 100% de umidade relativa, os dentes foram seccionados, resultando em fatias com 1mm de espessura. A fatia obtida foi observada em MEV para avaliar qualitativamente possíveis diferenças estruturais. Os valores dos testes de RF, RS e RU foram submetidos a Análise de Variância e teste de Tukey (?=5%). Como resultados na RF, a reação de presa com ultrassom resultou em maiores valores e semelhantes aos grupos controle negativo, independente da forma de apresentação do CIVAV. Para RS (Ra) o grupo Fuji IX mostrou maiores valores quando houve aplicação de ultrassom. Os demais grupos apresentaram resultados semelhantes. Para o parâmetro Sa houve diferença estatística em relação a apresentação do material e Equia Fill apresentou maiores valores de Sa. Para o teste de RU Fuji IX apresentou melhor desempenho nos grupos que receberam ativação por ultrassom e LED. Equia Fill não foi influenciado por nenhum tipo de fonte externa na RU. Com relação ao padrão de fratura, as fraturas adesivas/mistas apresentaram maior frequência independente do grupo experimental. As imagens de MEV mostram a região de interação do material com a dentina. Concluímos que o uso do ultrassom influenciou positivamente na RF, porém gerou maiores valores de RS (Ra) no grupo Fuji IX. Equia Fill tem maiores valores de RS (Sa). LED e ultrassom influenciaram positivamente o grupo Fuji IX na RU. / This study evaluated the influence of acceleration setting reaction by ultrasound, halogen light and light emitting diode (LED). For the analysis, the specimens were divided into nine groups according to the material - HVGIC powder-liquid version (Fuji Gold Label IX GP- GC Corp.), HVGIC encapsulated version (Equia Fill - GC Corp.) and the acceleration setting reaction original - negative control; ultrasound application for 20 seconds, irradiated with halogen light for 60 seconds, irradiated with LED for 60 seconds, and a positive control group of resin modified glass ionomer cement (RMGIC) powder-liquid version (Fuji II LC - GC Corp.) . For flexural strength test (FS) there were prepared 90 specimens (25x2x2mm) (n=10). After storage in water for 24 hours at 37°C, specimens were subjected to the FS test three points (1min/min). For the surface roughness analysis (SR), 45 specimens (n=5) previously prepared to the FS test were randomly selected from each group, and the average of 5 readings was analysed in Sa and Ra parameters. For the bond strength test (BS) 90 primary molars (n = 10) were selected and polyethylene cannulae were positioned on the flat pretreated dentin surface filled by one of the GICs and apply one of the setting reaction accelerators according to the experimental group. After storage in distilled water for 24 hours at 37°C, specimens were subjected to microshear test (1.0 mm/min). The fracture pattern was analyzed in stereomicroscope (400X). To evaluate the interaction dentin-GIC were selected 27 deciduous canines (n= 3), a cavity (4x2x2mm) was prepared in the buccal surface and then restored with the GIC accordingly to groups. After stored for 48 hours at 37°C and 100% relative humidity, the teeth were sectioned, resulting in slices with 1mm thickness. The slice obtained was observed by scanning electron microscope (SEM) to assess qualitatively possible structural differences. The values of FS testing, SR and BS were submitted to ANOVA and Tukey\'s test (? = 5%). As a result the FS, the ultrasound with setting reaction resulted in higher values and similar to the negative control group, regardless of the format of the HVGIC. SR for Ra parameter Fuji IX group showed higher values when there was application of ultrasound. The other groups showed similar results. For Sa parameter was no statistical difference regarding the presentation of material and Equia Fill showed higher Sa. For the BS Fuji IX test performed better in the groups receiving activation with Ultrasound and LED. Equia Fill was not influenced by any outside source. Regarding the fracture pattern, the adhesive / mixed fractures prevailed, regardless of experimental group. The SEM images showed the interaction region of the material to dentin. We conclude that the use of ultrasound positively influences the RF, but generated higher SR values (Ra) in Fuji IX group. Equia Fill SR has higher values f(Sa). LED ultrasound and positively influenced the Fuji IX group in the BS.
33

Efeitos de um cimento de ionômero de vidro e de um selante resinoso em esmalte bovino desmineralizado, submetido ou não a desafio cariogênico - estudo ‘in situ’ / Effects of a glass ionomer cement and a resin sealant on bovine demineralized enamel, submitted or not to a cariogenic challenge - in situ study

Hoshi, Adriano Tomio 12 September 2006 (has links)
Este estudo in situ avaliou em esmalte bovino desmineralizado, submetido ou não a um desafio cariogênico, os efeitos de um cimento de ionômero de vidro de alta viscosidade (CIVav) e de um selante resinoso, comparativamente a um controle (sem selamento). Doze voluntários usaram dispositivos intrabucais palatinos (DIP) contendo 12 blocos de esmalte bovino desmineralizado, fixados dois a dois para simular uma fissura em V, a qual foi selada com um dos materiais: CIVav (Ketac, Molar Easymix), selante resinoso (Delton) ou controle (sem selamento). Metade dos espécimes foi submetida ao acúmulo de biofilme, recebendo oito aplicações diárias de sacarose a 20% para provocar um desafio cariogênico, além de outras três, de solução de dentifrício fluoretado (1 g : 3 mL), enquanto a outra metade não sofreu acúmulo de biofilme, mas também recebeu o dentifrício. Após 14 dias, foram avaliadas as concentrações de flúor no biofilme e no esmalte, bem como o conteúdo mineral (microdureza em secção longitudinal). Os dados obtidos foram analisados estatisticamente ('alfa'= 5%). O teste Friedman ANOVA revelou que a concentração de flúor no biofilme foi estatisticamente maior com o uso do CIVav, em comparação ao selante resinoso e ao controle. A ANOVA e o teste de Tukey constataram que houve maior concentração de flúor no esmalte associado ao CIVav, sobretudo na ausência de desafio cariogênico, enquanto o selante resinoso e controle foram semelhantes. Em relação ao conteúdo mineral, a ANOVA e o teste de Tukey detectaram diferenças entre os grupos na camada mais superficial do esmalte. Com desafio cariogênico, o conteúdo mineral foi sempre maior no esmalte associado ao CIVav do que naquele associado ao selante resinoso, sendo que o controle apresentou resultados intermediários. Sem o desafio cariogênico, houve uma tendência de um maior conteúdo mineral no grupo controle. Os resultados sugerem que o CIVav, aplicado sobre uma superfície desmineralizada e sob desafio cariogênico, demonstrou um potencial cariostático pela sua capacidade de doar flúor à estrutura e ao biofilme dentários, minimizando os efeitos da desmineralização, mas não melhorou a remineralização. / This in situ study evaluated on demineralized bovine enamel, submitted or not to a cariogenic challenge (dental biofilm), the effects of a high viscosity glass ionomer cement (HV-GIC) and a resin sealant in comparison with a control group (without sealing). Twelve volunteers wore a palatal appliance containing 12 blocks of demineralized bovine enamel mounted (2 by 2) to simulate a fissure in a V shape and sealed with: HV-GIC (Ketac? Molar Easymix), resin sealant (Delton) or maintained with no sealing material (control). Half of specimens was submitted to a cariogenic challenge by dripping a 20% sucrose solution 8 times/day besides a fluoride dentifrice solution (1 g : 3 mL) 3 times/day. The others specimens only received a dentifrice solution. After 14 days, the concentration of fluoride in dental biofilm and enamel was evaluated as well as the mineral content (cross-sectional microhardness) of the enamel. The concentration of fluoride in dental biofilm was higher with HV-GIC (Friedman ANOVA, p<0.05) in comparison with resin sealant and control group. The concentration of loosely-bound fluoride on enamel was significant (ANOVA and Tukey test, p< 0.05) specially without a cariogenic challenge for HVGIC, while it was similar for the resin sealant and control group. Concerning the mineral content, ANOVA and Tukey test (p<0.05) detected differences among the groups on the superficial layers of the enamel. Under the dental biofilm influence the mineral content was always higher on the enamel associated with HV-GIC than with resin sealant and the control group presented intermediary results. Without dental biofilm the control group presented a tendency of a higher mineral content. The results suggest that HV-GIC applied on a demineralized surface and under the dental biofilm influence has shown a cariostatic potential by its ability to give fluoride to the dental structure and biofilm reducing the demineralization effects.
34

Influência da aceleração de presa por meio de ultrassom, luz halógena e diodo emissor de luz nas propriedades e resistência de união à dentina de cimentos de iônomero de vidro / Influence of accelaration setting reaction by ultrasound, halogen light and light emitted diode on properties and bond strength of glass ionomer cement

Laysa Yoshioka 17 February 2016 (has links)
Este estudo avaliou a influência da aceleração de presa de cimentos de ionômero de vidro de alta viscosidade (CIVAV) por meio de ultrassom, luz halógena e diodo emissor de luz (LED). Para as análises, os espécimes foram divididos em nove grupos de acordo com o material - CIVAV versão pó-líquido (Fuji Gold Label IX GPGC Corp.), CIVAV versão encapsulado (Equia Fill - GC Corp.) e a aceleração de presa inicial - controle negativo; aplicação de ultrassom por 20s, irradiados com luz halógena por 60s, irradiados com LED por 60s, além de um grupo controle positivo de cimento de ionômero de vidro modificado por resina (CIVMR) versão pó-líquido (Fuji II LC - GC Corp.). Para o teste de resistência flexural (RF) foram preparados 90 espécimes (25x2x2mm) (n=10), após armazenamento em água destilada por 24h a 37°C, os espécimes foram submetidos ao teste de RF de três pontos (1mm/min). Para a análise de rugosidade superficial (RS), 45 espécimes (n=5) previamente preparados para o teste de RF, foram selecionados aleatoriamente em cada grupo. A medida da RS (parâmetros Sa e Ra) do corpo de prova foi dada pela média de 5 leituras realizadas na superfície. Para o teste de resistência de união (RU), 90 molares decíduos (n=10) foram selecionados e cânulas de polietileno foram posicionadas sobre as superfícies planas de dentina pré-tratadas, preenchidas por um dos CIV e aplicado um dos aceleradores de presa de acordo com o grupo experimental. Após armazenamento em água destilada por 24h a 37°C, os espécimes foram submetidos ao teste de microcisalhamento (1,0 mm/min). O padrão de fratura foi analisado em microscópio esteroscópico (400 X). Para avaliar a interação dentina-CIV, foram selecionados 27 caninos decíduos (n=3), foi preparada uma cavidade (4x2x2mm) na superfície vestibular, então a cavidade foi restaurada com um dos CIV propostos pelo estudo para então ser aplicado um dos aceleradores de presa de acordo com o grupo experimental. Após armazenados por 48h a 37ºC e 100% de umidade relativa, os dentes foram seccionados, resultando em fatias com 1mm de espessura. A fatia obtida foi observada em MEV para avaliar qualitativamente possíveis diferenças estruturais. Os valores dos testes de RF, RS e RU foram submetidos a Análise de Variância e teste de Tukey (?=5%). Como resultados na RF, a reação de presa com ultrassom resultou em maiores valores e semelhantes aos grupos controle negativo, independente da forma de apresentação do CIVAV. Para RS (Ra) o grupo Fuji IX mostrou maiores valores quando houve aplicação de ultrassom. Os demais grupos apresentaram resultados semelhantes. Para o parâmetro Sa houve diferença estatística em relação a apresentação do material e Equia Fill apresentou maiores valores de Sa. Para o teste de RU Fuji IX apresentou melhor desempenho nos grupos que receberam ativação por ultrassom e LED. Equia Fill não foi influenciado por nenhum tipo de fonte externa na RU. Com relação ao padrão de fratura, as fraturas adesivas/mistas apresentaram maior frequência independente do grupo experimental. As imagens de MEV mostram a região de interação do material com a dentina. Concluímos que o uso do ultrassom influenciou positivamente na RF, porém gerou maiores valores de RS (Ra) no grupo Fuji IX. Equia Fill tem maiores valores de RS (Sa). LED e ultrassom influenciaram positivamente o grupo Fuji IX na RU. / This study evaluated the influence of acceleration setting reaction by ultrasound, halogen light and light emitting diode (LED). For the analysis, the specimens were divided into nine groups according to the material - HVGIC powder-liquid version (Fuji Gold Label IX GP- GC Corp.), HVGIC encapsulated version (Equia Fill - GC Corp.) and the acceleration setting reaction original - negative control; ultrasound application for 20 seconds, irradiated with halogen light for 60 seconds, irradiated with LED for 60 seconds, and a positive control group of resin modified glass ionomer cement (RMGIC) powder-liquid version (Fuji II LC - GC Corp.) . For flexural strength test (FS) there were prepared 90 specimens (25x2x2mm) (n=10). After storage in water for 24 hours at 37°C, specimens were subjected to the FS test three points (1min/min). For the surface roughness analysis (SR), 45 specimens (n=5) previously prepared to the FS test were randomly selected from each group, and the average of 5 readings was analysed in Sa and Ra parameters. For the bond strength test (BS) 90 primary molars (n = 10) were selected and polyethylene cannulae were positioned on the flat pretreated dentin surface filled by one of the GICs and apply one of the setting reaction accelerators according to the experimental group. After storage in distilled water for 24 hours at 37°C, specimens were subjected to microshear test (1.0 mm/min). The fracture pattern was analyzed in stereomicroscope (400X). To evaluate the interaction dentin-GIC were selected 27 deciduous canines (n= 3), a cavity (4x2x2mm) was prepared in the buccal surface and then restored with the GIC accordingly to groups. After stored for 48 hours at 37°C and 100% relative humidity, the teeth were sectioned, resulting in slices with 1mm thickness. The slice obtained was observed by scanning electron microscope (SEM) to assess qualitatively possible structural differences. The values of FS testing, SR and BS were submitted to ANOVA and Tukey\'s test (? = 5%). As a result the FS, the ultrasound with setting reaction resulted in higher values and similar to the negative control group, regardless of the format of the HVGIC. SR for Ra parameter Fuji IX group showed higher values when there was application of ultrasound. The other groups showed similar results. For Sa parameter was no statistical difference regarding the presentation of material and Equia Fill showed higher Sa. For the BS Fuji IX test performed better in the groups receiving activation with Ultrasound and LED. Equia Fill was not influenced by any outside source. Regarding the fracture pattern, the adhesive / mixed fractures prevailed, regardless of experimental group. The SEM images showed the interaction region of the material to dentin. We conclude that the use of ultrasound positively influences the RF, but generated higher SR values (Ra) in Fuji IX group. Equia Fill SR has higher values f(Sa). LED ultrasound and positively influenced the Fuji IX group in the BS.
35

Avaliação de dois cimentos de ionômero de vidro comparados a um selante resinoso, utilizados para selamento de fossas e fisuras aplicados em esmalte bovino hígido, sob condições de severo desafio cariogênico: estudo in situ / Evaluation of two glass ionomer cements compared to a resin sealant, employed for pit and fissure sealing on intact bovine enamel, under severe cariogenic challenge - in situ study

Biella, Vivian de Agostino 02 March 2007 (has links)
Este estudo in situ, desenvolvido em uma fase de 14 dias, teve como objetivo avaliar o efeito de dois cimentos de ionômero de vidro (CIV) comparados a um selante resinoso, utilizados para selamento de fossas e fissuras aplicados em esmalte bovino hígido, com acúmulo de biofilme dentário, por meio da análise do conteúdo de flúor do biofilme dentário e da microdureza em secção longitudinal. Foram utilizados 88 blocos de esmalte (4mm x 4mm) de incisivos bovinos, selecionados por seu valor de microdureza inicial. Os blocos formaram uma fissura artificial em forma de \"V\" a qual foi selada, para compor os seguintes grupos: GI-CIVav (Ketac? Molar Easymix); GII-CIV modificado por resina (Vitremer?); GIII-selante resinoso sem flúor (Helioseal® Clear) ou GIV-controle, sem selamento. As fissuras artificiais foram fixadas em um dispositivo intrabucal palatino (DIP), em duas fileiras distintas que foram cobertas por uma tela plástica para favorecer o acúmulo de biofilme dentário. Onze voluntários utilizaram o DIP 24 h/dia; gotejaram 8x/dia, uma solução de sacarose a 20% e, uma solução de dentifrício fluoretado (3ml de água deionizada : 1g de dentifrício fluoretado) sobre todas as fissuras 3x/dia. Após o período experimental, coletou-se o biofilme acumulado para a avaliação do conteúdo de flúor. As fissuras foram seccionadas ao meio para a avaliação da microdureza em secção longitudinal a partir da superfície do esmalte, em 4 profundidades (10, 30, 50, 70 µm). O limite esmalte/material da região oclusal era a posição zero (borda do material) e, a partir deste, realizadas seqüências de impressões a 50, 150 e 500 µm interna e externamente à borda do material. Os dados obtidos foram analisados estatisticamente (a= 5%). O teste de Friedman revelou que a concentração de flúor no biofilme não foi estatisticamente significante entre os grupos, (p<0,07), com uma tendência de melhores resultados para o CIVav. Quanto ao conteúdo mineral, a ANOVA e o teste de Tukey detectaram significância (p<0,05) para todos os grupos individualmente, na camada mais superficial do esmalte (10 µm). Nesta profundidade, não houve diferença entre os grupos. Essas comparações foram válidas para a maioria das distâncias analisadas. / This in situ study, developed in a 14-day period, aimed to evaluate the effect of two glass ionomer cements (GIC) compared to a resin sealant, employed for pit and fissure sealing on intact bovine enamel, with accumulation of dental biofilm, by analysis of the fluoride content on the dental biofilm and longitudinal microhardness. Eighty-eight enamel blocks (4mm x 4mm) of bovine incisors were employed, selected according to their initial microhardness value. The blocks formed a V-shaped artificial fissure that was sealed, constituting the following groups: GI - high-viscosity conventional GIC (Ketac? Molar Easymix); GII - resin-modified GIC (Vitremer?); GIII - resin sealant without fluoride (Helioseal? Clear); and GIV - control, without sealing. The artificial fissures were fixated on a palatal plate (PP), in two distinct rows, which were covered with a plastic screen to favor the accumulation of dental biofilm. Eleven volunteers employed the PP for 24h/day, dripped a 20% sucrose solution 8 times a day, and used a fluoridated dentifrice solution (3ml of deionized water : 1g of fluoridated dentifrice) on all fissures 3 times a day. After the study period, the accumulated biofilm was collected for evaluation of the fluoride content. The fissures were sectioned through the middle for evaluation of longitudinal microhardness from the enamel surface, at 4 depths (10, 30, 50, 70 µm). The enamel/material limit at the occlusal region was the zero position (material margin); from this point, indents were sequentially performed at 50, 150 and 500 µm internally and externally to the material margin. Data were statistically analyzed (a = 5%). The Friedman test revealed that the fluoride concentration in the biofilm was not statistically significantly different among groups (p<0.07), yet there was a tendency of better outcomes for the high-viscosity conventional GIC. With regard to the mineral content, the ANOVA and Tukey test revealed significance (p<0.05) for all groups individually, at the most superficial enamel layer (10 µm). At this depth, there was no difference among groups. These comparisons were valid for most distances analyzed..
36

Estudo da radiopacidade de materiais odontológicos indicados como base e forramento de restaurações. Análise através da radiografia digital / Study of the radiopacity of dental materials used as base and liner of restorations. Analysis by digital radiographic

Lachowski, Karina Monteleone 03 June 2011 (has links)
A radiopacidade é um importante pré-requisito para materiais utilizados como base e forramento de restaurações, pois possibilita que o profissional identifique a presença do material e permita sua diferenciação com a estrutura dental adjacente. O objetivo desse estudo foi avaliar a radiopacidade de materiais indicados como base e forramento e comparar com a radiopacidade do esmalte, dentina e escala de alumínio. Para isso, foram analisadas 16 marcas comerciais de cimento de ionômero de vidro, 8 marcas de resina composta flow e 4 marcas de cimento de hidróxido de cálcio. Foram confeccionados três conjuntos de três corpos de prova de 4 mm de diâmetro, com espessuras de 1, 2 e 3 mm para cada cimento de ionômero de vidro e resina composta flow e de 1 mm para cada cimento de hidróxido de cálcio. Foram feitas secções transversais de coroas de três terceiros molares humanos para obtenção de espécimes de esmalte e dentina com espessura de 1, 2 e 3 mm. Como controle, uma escala de alumínio padrão com nove degraus de espessura foi utilizada. As tomadas radiográficas foram feitas com o sistema digital RVG 5000 Kodak (Kodak Company, França) e tempo de exposição de 0.32 segundos. As imagens obtidas foram trabalhadas no programa Image Tool® para obtenção dos valores médios de cinza. A análise estatística ANOVA, seguida pelo teste de Tukey (p0.05) detectou diferenças consideráveis entre os materiais da mesma categoria e entre as espessuras. Algumas marcas comerciais apresentaram radiopacidade inadequada segundo as normas ISO 4049 e 9917 (Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R e Vidrion F), apresentando radiopacidade inferior à da dentina, insuficiente para um correto diagnóstico. Todas as resinas compostas flow e cimentos de hidróxido de cálcio estudados apresentam radiopacidade superior a da dentina. As marcas comerciais Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil Tetric N, Tetric, Hydro C, Hydcal e Liner apresentaram radiopacidade igual ou superior a do esmalte, em todas as espessuras. De um modo geral, o aumento de espessura dos materiais estudados aumenta significativamente sua radiopacidade. Conclui-se que existem materiais indicados como base e forramento de restaurações com radiopacidade inadequada para serem detectados radiograficamente. / Radiopacity is an important pre-requisite for base and liner materials, once it allows the professional to identify the presence of the material and makes its differentiation from the adjacent tooth structure possible. The aim of this study was to evaluate the radiopacity of liner and base materials and compare to the radiopacity of enamel, dentin and aluminum stepwedge. For this, 16 glass ionomer cements, 8 flowable resin composites and 4 calcium hydroxide cements were analysed. It was prepared three sets of three test specimens with 4 mm in diameter and thicknesses of 1, 2 and 3 mm for each glass ionomer cement and flowable composite and 1 mm for each calcium hydroxide cement. Cross sections were made from crowns of three third molars to obtain specimens of enamel and dentin with thickness of 1, 2 and 3 mm. As a control, a standard aluminum stepwedge with nine steps was used. Radiographs were taken with digital Kodak RVG 5000 (Kodak Company, France) and exposure time of 0.32 seconds. The images were analysed through the program Image Tool ® to obtain the mean grey values. Statistical test ANOVA followed by Tukey test (p 0.05) detected significant differences between the materials of the same category and between the thicknesses. The commercial brands Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R and Vidrion F, presented radiopacity lower than the radiopacity of dentin, insufficient for a correct diagnostic. All flowable resin composites and calcium hydroxide cements studied showed radiopacity superior than dentin. Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil, Tetric N, Tetric, Hydro C, Hydcal and Liner showed radiopacity equal to or greater than the enamel for all thicknesses. In general, the increased thickness of the materials studied increases its radiopacity significantly. It was concluded that some materials indicated as base and liner for restorations have and inadequate radiopacity to be detected radiographically.
37

A influência do material restaurador na sobrevida de restaurações ART em molares decíduos baseado em Ensaios Clínicos Randomizados / The influence of restorative material on survival of ART restorations in primary molars based on Randomized Clinical Trials

Costa, Isabel Cristina Olegario da 21 September 2018 (has links)
Este trabalho envolve os resultados de três diferentes ensaios clínicos randomizados: (1) restaurações ART em cavidades oclusais utilizando Fuji IX (GC), Vitro Molar (Nova DFL) e Maxxion R (FGM); (2) restaurações ART oclusoproximais utilizando Ketac Molar (3M ESPE) e Vitro Molar (Nova DFL) e (3) Restaurações ART em cavidades oclusais e ocluso-proximais utilizando Glass Carbomer (GCP), Dyract (Dentsply) e Equia Fill (GC). O objetivo desta tese foi avaliar se a escolha do material tem influência na sobrevida de restaurações ART em molares decíduos. Um total de 835 crianças de 4 a 8 anos de idade (estudo 1: n=150; estudo 2: n=117; estudo 3: n=568) com lesões de cárie em dentina sem sinais de envolvimento pulpar foram selecionadas e tratadas em escolas públicas do município de Barueri-SP. Os pacientes foram randomizados de acordo com o grupo de material restaurador de cada estudo. Todos os tratamentos foram feitos seguindo os preceitos do ART e as recomendações dos fabricantes. As restaurações foram avaliadas por examinador independente, treinado e calibrado (estudo 1 e 2: até 24 meses e estudo 3: até 36 meses de acompanhamento). Para verificação da sobrevida das restaurações foi utilizada a análise de sobrevida de Kaplan-Meier e teste log-rank. Para avaliar a associação entre o desfecho e as variáveis características do paciente foi aplicado o teste de Regressão de Cox (IC=95%). No estudo 1, a sobrevida de restaurações oclusais em molares dentes decíduos é maior ao utilizar o material Fuji IX (72,7%) quando comparado aos materiais VitroMolar (46,5%) e Maxxion R (39,6%). Não houve diferenças entre os materiais Maxxion R e Vitro Molar. No estudo 2, monstrou-se que sobrevida de restaurações oclusoproximais é maior ao utilizar o material Ketac Molar (48,6%) quando comparado ao VitroMolar (25,4%). Já no estudo 3, o material Glass Carbomer (CAR) apresenta menor sobrevida quando comparado ao cimento de ionômero de vidro de alta viscosidade (CIV)- Equia Fill e ao compômero (COM)- Dyract, tanto em cavidades oclusais (CIV=83%; COM=78%; CAR=62,5%) quanto em ocluso-proximais oclusais (CIV=56,19%; COM=56,15%; CAR=36,33%). Nenhuma diferença é observada entre o compômero e o cimento de ionômero de vidro de alta viscosidade. Outros fatores como sexo, arcada, lado, experiência de 38 cárie, operador e volume da cavidade não influenciaram a sobrevida das restaurações (p>0,05). Dessa forma, conclui-se que a sobrevida das restaurações ART em molares decíduos é influenciada pela escolha do material restaurador. Os materiais que apresentaram melhores resultados nestes ensaios clínicos randomizados foram: Fuji IX (GC Corp), Ketac Molar (3M ESPE), Equia Fill (GC Corp) e Dyract (Dentsply). Registro no ClinicalTrials.gov: Capítulo 1: NCT02377297; Capítulo 2: NCT02267720; Capítulo 3: NCT02217098. / This thesis compiles the results of three different randomized clinical trials: (1) ART occlusal restorations using Fuji IX (GC), Vitro Molar (Nova DFL) and Maxxion R (FGM); (2) ART occlusal restorations using Ketac Molar (3M ESPE) and Vitro Molar (Nova DFL) and (3) ART restorations in occlusal and occlusoproximal cavities using Glass Carbomer (GCP), Dyract (Dentsply) and Equia Fill (GC). The aim of this thesis was to evaluate if the restorative material can influence the survival of ART restorations in primary dentition. A total of 835 children 4 to 8 years of age (study 1: n = 150, study 2: n = 117, study 3: n = 568) with dentin carious lesions without pulp involvement were selected and treated in public schools of the city of Barueri-SP. Patients were randomized according to the restorative material group of each study. All treatments were done following the ART precepts and the manufacturers\' recommendations. Restorations were evaluated by single trained and calibrated examiner (study 1 and 2: up to 24 months and study 3: up to 36 months follow-up). Kaplan-Meier survival analysis and log-rank test were used to verify the survival of the restorations. The Cox Regression test was used to evaluate the association between the outcome and the independent variables (CI=95%). In study 1, the survival of occlusal restorations in primary molars was higher using Fuji IX (72.7%) when compared to VitroMolar (46.5%) and Maxxion R (39.6%). There were no differences between Maxxion R and VitroMolar. In study 2, it was shown that survival of occlusoproximais restorations is higher when using Ketac Molar (48.6%) when compared to VitroMolar (25.4%). In the study 3, Glass Carbomer (CAR) material presented lower survival when compared to the high viscosity glass ionomer (GIC) - Equia Fill and to compomer (COM) - Dyract, both in occlusal cavities (GIC = 83%, COM = 78%, CAR = 62.5%) and occlusal-proximal ones (GIC = 56.19%, COM = 56.15%, CAR = 36.33%). No difference is observed between the compomer and the high viscosity glass ionomer cement. Other factors such as sex, jaw, side, caries experience, operator and volume of the cavity did not influence the survival of the restorations (p> 0.05). Thus, it is concluded that survival of ART restorations in primary molars is influenced by the restorative material. The materials that showed 40 the best results in these randomized controlled trials were Fuji IX (GC Corp), Ketac Molar (3M ESPE), Equia Fill (GC Corp) and Dyract (Dentsply). ClinicalTrials.gov Registration: Chapter 1: NCT02377297; Chapter 2: NCT02267720; Chapter 3: NCT02217098.
38

Estereologia, imuno-histoquímica e microscopia eletrônica de varredura na análise da reação tecidual a implantes de discos de adesivo dentinário fotoativado, hidróxido de cálcio e cimento de ionômero de vidro: estudo experimental em ratos / Stereology, imunohistochemistry, and scanning electron microscopy in the analysis of tissue reaction to disks implants of light-cured dentin adhesive, calcium hydroxide, and glass ionomer cement: experimental study in rats

Rogério Luiz de Oliveira Mussel 17 May 2002 (has links)
Objetivo: avaliar a biocompatibilidade de materiais indicados como protetores pulpar no tecido subcutâneo de ratos ao longo do tempo. Métodos: Implantes padronizados de Hidróxido de Cálcio (HC), Cimento de Ionômero de Vidro (CIV) e Adesivo Dentinário Fotoativado (ADF) foram colocados cirurgicamente no dorso de ratos Wistar e deixados por 15 e 30 dias (cada grupo com 5 animais) e os respectivos grupos sham (S). Após a experimentação os animais foram sacrificados e material do dorso dos animais foi retirado para estudo ao microscópio de luz com estereologia e imuno-histoquímica para &#945;-actina de músculo liso (ACML, detecção de miofibroblastos). As pastilhas e a superfície das cápsulas fibrosas foram analisadas quanto a textura, em microscopia eletrônica de varredura (MEV) com microanálise. Resultados: Houve diferenças na fibrose e no número de mastócitos na região peri-implante dependente do tipo de implante. Não foram detectados miofibroblastos expressando ACML. O menor valor de densidade volumétrica de fibrose intersticial (Vv[f]) ocorreu no grupo HC, e o maior no grupo ADF (diferença significativa em relação ao grupo S, nos dois tempos experimentais, p<0,05). Entretanto, aos 30 dias, houve acréscimo de 30% de Vv[f] do grupo ADF, determinando, neste período, diferença significativa em relação ao grupo HC. Quanto a densidade numérica de mastócitos por área (NA[mastócito]) o menor valor ocorreu no grupo HC sem diferença para o grupo S, mas diferença para o grupo ADF (este com o maior valor de NA[mastócito] nos dois tempos experimentais). O grupo CIV apresentou, para Vv[f] e NA[mastócito], durante toda a experimentação, resultados intermediários aos grupos HC e ADF. Houve fibrose discreta e restrita a área cirúrgica com poucos mastócitos juntos aos vasos no grupo S. Houve correlação positiva para Vv[f] e NA[mastócito], no grupo ADF. Ao MEV viu-se interação, no grupo HC, entre o material da pastilha e sua cápsula fibrótica, mas não nos grupos ADF e CIV. Conclusão: Os materiais estudados induziram a formação de fibrose e migração de mastócitos de modo diferenciado. Os resultados sugerem o HC como o material mais compatível biologicamente dentre os testados neste trabalho. / Purpose: to evaluate the biocompatibility of some pulpar protecting materials in the subcutaneous tissue of rats along the time. Methods: standardized implants of Calcium Hydroxide (CH), Glass Ionomer Cement (GIC) and Light-cured Dentin Adhesive (LDA) surgically were put in the back of Wistar rats and left by 15 and 30 days (each group with 5 animals) and the respective sham groups (S). After the experimentation the animals were sacrificed and material from the back of the animals was removed for study with light microscope, stereology and immunohistochemistry for smooth muscle alfa-actin (SMAA, myofibroblast detection). The implants and the fibrous capsule surfaces were analyzed with the scanning electronic microscopy (SEM) adapted with microanalysis. Results: the fibrosis and the number of mastocytes were different in the implant area depending of the implant type. Myofibroblasts were not detected expressing SMAA. The smallest value of the volume density of interstitial fibrosis (Vv[f]) occured in the CH group, and the largest in the LDA group (the difference was significant in relation to the S group, in the two experimental times, p < 0.05). However, to the 30 days, the Vv[f] of the LDA group increase 30%, being different from the CH group in this period. The numerical density of mastocytes per area (NA[mastocyte]) was smaller in the CH group without difference for the S group, but with difference from the LDA group (this group had the largest NA[mastocyte] value in the two experimental times). The GIC group had, for Vv[f] and NA[mastocyte] all experimentation time, intermediary values ranging from CH to LDA values. There was discreet and restricted fibrosis in the surgical area with few mastocytes associated to vessels in the S group. There was positive correlation for Vv[f] and NA[mastocyte] in the LDA group. In the CH group the SEM observed interaction between the implant material and its fibrotic capsule, but not in the LDA and GIC groups. Conclusion: The studied materials induced the fibrosis formation and mastocytes migration in a differentiated way. The results suggest that CH as the most biologically compatible material among the materials tested in this work.
39

Estereologia, imuno-histoquímica e microscopia eletrônica de varredura na análise da reação tecidual a implantes de discos de adesivo dentinário fotoativado, hidróxido de cálcio e cimento de ionômero de vidro: estudo experimental em ratos / Stereology, imunohistochemistry, and scanning electron microscopy in the analysis of tissue reaction to disks implants of light-cured dentin adhesive, calcium hydroxide, and glass ionomer cement: experimental study in rats

Rogério Luiz de Oliveira Mussel 17 May 2002 (has links)
Objetivo: avaliar a biocompatibilidade de materiais indicados como protetores pulpar no tecido subcutâneo de ratos ao longo do tempo. Métodos: Implantes padronizados de Hidróxido de Cálcio (HC), Cimento de Ionômero de Vidro (CIV) e Adesivo Dentinário Fotoativado (ADF) foram colocados cirurgicamente no dorso de ratos Wistar e deixados por 15 e 30 dias (cada grupo com 5 animais) e os respectivos grupos sham (S). Após a experimentação os animais foram sacrificados e material do dorso dos animais foi retirado para estudo ao microscópio de luz com estereologia e imuno-histoquímica para &#945;-actina de músculo liso (ACML, detecção de miofibroblastos). As pastilhas e a superfície das cápsulas fibrosas foram analisadas quanto a textura, em microscopia eletrônica de varredura (MEV) com microanálise. Resultados: Houve diferenças na fibrose e no número de mastócitos na região peri-implante dependente do tipo de implante. Não foram detectados miofibroblastos expressando ACML. O menor valor de densidade volumétrica de fibrose intersticial (Vv[f]) ocorreu no grupo HC, e o maior no grupo ADF (diferença significativa em relação ao grupo S, nos dois tempos experimentais, p<0,05). Entretanto, aos 30 dias, houve acréscimo de 30% de Vv[f] do grupo ADF, determinando, neste período, diferença significativa em relação ao grupo HC. Quanto a densidade numérica de mastócitos por área (NA[mastócito]) o menor valor ocorreu no grupo HC sem diferença para o grupo S, mas diferença para o grupo ADF (este com o maior valor de NA[mastócito] nos dois tempos experimentais). O grupo CIV apresentou, para Vv[f] e NA[mastócito], durante toda a experimentação, resultados intermediários aos grupos HC e ADF. Houve fibrose discreta e restrita a área cirúrgica com poucos mastócitos juntos aos vasos no grupo S. Houve correlação positiva para Vv[f] e NA[mastócito], no grupo ADF. Ao MEV viu-se interação, no grupo HC, entre o material da pastilha e sua cápsula fibrótica, mas não nos grupos ADF e CIV. Conclusão: Os materiais estudados induziram a formação de fibrose e migração de mastócitos de modo diferenciado. Os resultados sugerem o HC como o material mais compatível biologicamente dentre os testados neste trabalho. / Purpose: to evaluate the biocompatibility of some pulpar protecting materials in the subcutaneous tissue of rats along the time. Methods: standardized implants of Calcium Hydroxide (CH), Glass Ionomer Cement (GIC) and Light-cured Dentin Adhesive (LDA) surgically were put in the back of Wistar rats and left by 15 and 30 days (each group with 5 animals) and the respective sham groups (S). After the experimentation the animals were sacrificed and material from the back of the animals was removed for study with light microscope, stereology and immunohistochemistry for smooth muscle alfa-actin (SMAA, myofibroblast detection). The implants and the fibrous capsule surfaces were analyzed with the scanning electronic microscopy (SEM) adapted with microanalysis. Results: the fibrosis and the number of mastocytes were different in the implant area depending of the implant type. Myofibroblasts were not detected expressing SMAA. The smallest value of the volume density of interstitial fibrosis (Vv[f]) occured in the CH group, and the largest in the LDA group (the difference was significant in relation to the S group, in the two experimental times, p < 0.05). However, to the 30 days, the Vv[f] of the LDA group increase 30%, being different from the CH group in this period. The numerical density of mastocytes per area (NA[mastocyte]) was smaller in the CH group without difference for the S group, but with difference from the LDA group (this group had the largest NA[mastocyte] value in the two experimental times). The GIC group had, for Vv[f] and NA[mastocyte] all experimentation time, intermediary values ranging from CH to LDA values. There was discreet and restricted fibrosis in the surgical area with few mastocytes associated to vessels in the S group. There was positive correlation for Vv[f] and NA[mastocyte] in the LDA group. In the CH group the SEM observed interaction between the implant material and its fibrotic capsule, but not in the LDA and GIC groups. Conclusion: The studied materials induced the fibrosis formation and mastocytes migration in a differentiated way. The results suggest that CH as the most biologically compatible material among the materials tested in this work.
40

Análise comparativa entre dois sistemas digitais frente à radiopacidade de materiais dentários / Comparative analysis between two digital systems for analyzing radiopacity of restorative materials

Abílio, Vanessa Maria Freire 15 July 2013 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2016-10-26T11:47:13Z No. of bitstreams: 1 PDF - Vanessa Maria Freire Abílio.pdf: 2920508 bytes, checksum: 9dd2d9baca2d37200df8d4240c629561 (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2016-11-16T14:20:54Z (GMT) No. of bitstreams: 1 PDF - Vanessa Maria Freire Abílio.pdf: 2920508 bytes, checksum: 9dd2d9baca2d37200df8d4240c629561 (MD5) / Made available in DSpace on 2016-11-16T14:20:54Z (GMT). No. of bitstreams: 1 PDF - Vanessa Maria Freire Abílio.pdf: 2920508 bytes, checksum: 9dd2d9baca2d37200df8d4240c629561 (MD5) Previous issue date: 2013-07-15 / Digital image is a breakthrough in dental radiology characterized by being a quick and easy method of obtaining and evaluating of images. The aim of this study was to compare the semi-direct digital system (Digora Optime®) with the indirect digital system (CCD digital camera) in relation to radiopacity of dental materials indicated as base or liner. In addition, it was proposed to verify the influence of different exposure times and focus-film distances on the degree of radiopacity shown by these materials. A total of 10 specimens (4 X 2 mm) were made for each brand of restorative material employed (KetacTM Molar Easymix, Vidrion F, GC Fugi LiningTM LC, VitrebondTM, FiltekMR Z350 XT Flow and Tetric® N Flow), total of 60 specimens, by using an acrylic matrix. The specimens were radiographed together with an aluminum scale and cross-sections of teeth with 2 mm by both digital systems in four combinations of exposure time / different focus-film distances (0.12 s / 20 cm; 0.12 s /40 cm, 0.25 s /20 cm, 0.25 s /40 cm). The radiopacity of radiographed structures was measured using the tool “analyze histogram” on the software Image J. Data were analyzed using descriptive statistics and non-parametric tests: Wilcoxon, Mann- Whitney and Student’s t test. Only Vidrion F showed radiopacity lower than that of dentin and 2-mm cross-sections with statistically significant difference (p < 0.05) for all cases using the semi-direct digital system and for some cases using the indirect digital system. The radiopacity means for all materials studied were significantly higher (p <0.05) when the semi-direct digital system (Digora Optime®) was used. There was significant difference (p <0.05) in the radiopacity of the materials – except for Vidrion F – when exposure time and focus-film distance changed. It was concluded that the semi-direct digital system (Digora optime®) was more precise for measuring radiopacity compared to the indirect digital system. Thus, the semi-direct procedure is indicated to be used clinically as an auxiliary diagnostic method. / A imagem digital representa um grande avanço na Radiologia Odontológica, uma vez que constitui um método rápido de obtenção de imagem e de fácil avaliação. O objetivo deste trabalho foi comparar o sistema digital semi-direto utilizando o Digora Optime® com o sistema digital indireto que utilizou câmera digital de CCD, frente à radiopacidade dos materiais dentários indicados para base ou forramento, bem como verificar a influência da variação de tempo de exposição e da distância foco- filme no grau de radiopacidade apresentado por estes materiais. Foram confeccionados 10 corpos-de prova (4 X 2 mm) para cada marca de material dentário utilizada (KetacTM Molar Easymix, Vidrion F, GC Fugi LiningTM LC, VitrebondTM, tetricMR Z350 XT Flow e Tetric® N Flow), totalizando 60 espécimes, usando uma matriz acrílica. Os corpos-de-prova foram radiografados junto a uma escala de alumínio e secções transversais de dentes com 2mm, por ambos os sistemas digitais em quatro combinações de tempo de exposição/distância foco-filme diferentes(0,12s/20cm; 0,12s/40cm; 0,25s/20cm e 0,25s/40cm). A radiopacidade das estruturas radiografadas foram mensuradas utilizando a função analyse histogram do programa Image J. O dados foram analisados por meio da estatística descritiva e através dos testes não- paramétrico de Wilcoxon-Mann Whitney e teste T de Sudent. Apenas o Vidrion F apresentou radiopacidade inferior a dentina e ao degrau de 2mm do penetrômetro, sendo esta diferença significativa (p<0,05), para todas as situações utilizando o sistema digital semi-direto e, para algumas situações, utilizando o sistema digital indireto. As médias de radiopacidade para todos os materiais estudados foram significativamente maiores (p<0,05) quando foi utilizado o sistema digital semi-direto (Digora Optime®). Houve diferença significativa (p<0,05) na radiopacidade dos materiais, exceto para o Vidrion F, quando ocorreu variação no tempo de exposição, bem como quando ocorreu variação na distância foco-filme. Conclui-se que o sistema digital semi-direto (Digora optime®) mostrou ser mais preciso para as medições de radiopacidade quando comparado ao sistema digital indireto, sendo nesta situação mais indicado para ser utilizado clinicamente como método auxiliar de diagnóstico.

Page generated in 0.1703 seconds