• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 23
  • 23
  • 10
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Retração total e penetração de cloretos em concretos com cimento Portland branco e escória de alto forno / Total shrinkage and chloride penetration in concretes with white Portland cement and blast furnace slag

Dellinghausen, Luciano de Medeiros 25 June 2009 (has links)
Drying Shrinkage is a phenomenon that occurs in concrete, subjected or not to a load, due to water loss, once exposed to environment and allowed to dry. It is responsible for almost the entire total shrinkage strain in concrete. A concrete element with restrained shrinkage deformation may develop tensions that cause cracks, allowing the ingress of aggressive agents that may cause some damage to the reinforcement, reducing, consequently, its strength and durability. The most common aggressive agent into concrete is the chloride ion, which is considered the great responsible for the early reinforcement corrosion of concrete structures, affecting its stability and durability. Corrosion of reinforcement bars due to the ingress of salts from sea water into concrete is recognized to be the most influent factor in the destructive mechanisms for marine structures. The use of mineral admixtures such as blast furnace slag, the increase of curing duration and the water/binder ratio reduction are measures that may reduce the chloride ion penetration. The aim of this study was to investigate the influence of the cement replacement content by slag, as well as the duration of curing on drying shrinkage, chloride ion penetration and compressive strength of concretes made with high early age strength cement and white Portland cement. Water-binder ratios of 0.30, 0.42 and 0.55, curing duration of 3 and 7 days, besides the cement replacement contents of 0%, 50% and 70% were investigated. In order to analyze the influence of the alkali activation on the properties investigated, a concrete made with 50% white Portland cement replacement content by slag and activated by sodium sulfate (4% in mass of binder) was used. The compressive strength was evaluated in the ages of 3, 7, 28 and 91 days; the drying shrinkage in the ages of 7, 14, 21, 28, 35, 56, 91 and 182 days, and the chloride ion penetration (immersion test in chloride solution) in the ages of 7, 14, 28, 56 and 91 days. Before being immersed in the chloride solution, the specimens were subjected to a drying period of 91 days. The results obtained revealed that an increase in the slag content decreased the compressive strength and the drying shrinkage values, besides the smaller depths of chloride penetration with both cements used. Reducing the curing duration resulted greater drying shrinkage and depth of chloride penetration for both cements, independently the slag content. / A retração hidráulica é um fenômeno que ocorre no concreto, submetido ou não a carregamento, devido à perda de umidade, uma vez exposto ao meio ambiente e permitida sua secagem. Ela é responsável por praticamente toda a deformação total por retração no concreto. Um elemento de concreto com restrição de deformação por retração pode desenvolver tensões que levam à formação de fissuras, através das quais agentes agressivos podem penetrar e causar algum dano à armadura, reduzindo sua resistência e durabilidade. O agente agressivo mais comum é o íon cloreto, o qual é considerado como a maior causa de corrosão prematura das barras de armaduras das estruturas de concreto, afetando sua estabilidade e vida útil. A corrosão de armaduras devido ao ingresso de íons cloretos da água do mar no concreto é universalmente conhecida como o fator de maior influência nos mecanismos destrutivos de estruturas marinhas. A utilização de adições minerais como a escória de alto forno, o aumento no prazo de cura e a redução na relação água/aglomerante são medidas que podem diminuir a penetração desses íons no concreto. Este trabalho teve por objetivo investigar a influência do teor de escória e do período de cura na retração hidráulica, na penetração de íons cloretos e na resistência à compressão axial de concretos compostos de cimento Portland de alta resistência inicial e cimento Portland branco estrutural. Foram adotadas relações água/aglomerante de 0.30, 0.42 e 0.55, teores de escória, em substituição ao cimento Portland, de 0%, 50% e 70%, além de períodos de cura de 3 e 7 dias. Foi empregada uma mistura composta de 50% de escória em substituição ao cimento Portland branco, ativada quimicamente por sulfato de sódio (4% da massa de aglomerante) para analisar a influência do ativador nas propriedades investigadas. As idades avaliadas para o ensaio de resistência à compressão foram de 3, 7, 28 e 91 dias; para retração hidráulica idades de 7, 14, 21, 28, 35, 56, 91 e 182 dias e, para penetração de íons cloretos (imersão em solução salina) as idades de 7, 14, 28, 56 e 91 dias. Antes de serem imersos em solução salina os corpos-de-prova foram submetidos a um período de secagem de 91 dias. Dos resultados obtidos, constatou-se que o aumento do teor de escória resultou em decréscimo nos valores de resistência à compressão, de retração e de penetração de cloretos para os dois cimentos investigados. A diminuição no período de cura resultou em maiores valores de retração e de penetração de cloretos, tanto no concreto branco quanto no cinza, independentemente do teor de escória utilizado.
22

DESEMPENHO DO CIMENTO PORTLAND BRANCO COM ESCÓRIA DE ALTO-FORNO E ATIVADOR QUÍMICO FRENTE AO ATAQUE POR SULFATO DE SÓDIO / PERFORMANCE OF A WHITE PORTLAND CEMENT WITH SLAG AND CHEMICAL ACTIVATOR AGAINST SODIUM SULFATE ATTACK

Veiga, Karina Kozoroski 31 August 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Sulfate ions found in seawater, groundwater and wastewater are aggressive agents that can result in severe concrete degradation. They react with cement hydration products and depending on the associated cations present (magnesium, calcium, potassium, sodium, ammonium), their concentrations and the conditions of the environment, this can result in the formation of ettringite, gypsum or thaumasite, decalcification of C-S-H, processes which may cause expansion, cracking and loss of mass and strength.When high sulfate resistance is required, national and international standards prescribe the use of cement with high concentrations of granulated blast furnace slag (GBFS). By substituting GBFS for cement, lower amounts of clinker are required. In addition, the pozzolanic activity of GBFS takes up the CH released by the hydration of silicates (C3S e C2S), which then is not available to react with sulfate ions to form gypsum, resulting in a more dense paste with lower penetrability. GBFS is one of the few mineral admixtures that can be added to white Portland cement (WPC), a material with widespread usage in civil construction, particularly in cases where concrete is used as a finished surface for architectural impact. The substitution of GBFS for WPC offers technical and environmental gains as well as economic advantages due to the higher cost of WPC. This study investigated the sulfate resistance of WPC with 0%, 50% and 70% GBFS as a substitution for cement. A mix with 50% GBFS that was chemically activated with Na2SO4 (4% b/w of binder) was also studied. The performance of the blended cements was monitored by exposing the prepared mortar specimens to a solution of Na2SO4 (5%) for 2 years according to ASTM C1012/04 and using TG/DTA, DRX and SEM/EDX analyses of the paste samples. For comparison, the same blends prepared with high early strength Portland cement (PC) were also used. The results showed the benefits of the use of GBFS in both types of cement, with higher concentrations of slag resulting in improved sulfate resistance. The use of chemical activation reduced expansion when compared with mixtures without activation. For long-term exposure, all WPC blends showed lower expansion than the corresponding blends with PC. Microstructural analysis identified ettringite and gypsum as the main degradation products of the sulfate attack. / Os íons sulfato, encontrados na água do mar, em águas subterrâneas e em águas residuárias são agentes agressivos que podem levar a uma severa degradação do concreto. Ao reagirem com os produtos de hidratação do cimento, dependendo do tipo de cátion a que estão associados (magnésio, cálcio, potássio, sódio, amônio, etc.), da concentração e das condições do meio, podem levar à formação de etringita secundária, sulfato de cálcio, taumasita, descalcificação do C-S-H, podendo ocorrer expansão, fissuração, perda de massa e de resistência. Quando se faz necessário assegurar uma elevada resistência ao sulfato, a normalização nacional e internacional, dentre outras recomendações, especifica o uso de cimento com elevados teores de escória de alto-forno. Além da redução da quantidade de clínquer ocasionada pela substituição do cimento por escória, a atividade pozolânica da mesma consome o CH liberado pela hidratação dos silicatos (C3S e C2S), que não fica disponível para reagir com os sulfatos e formar sulfato de cálcio, e promove a densificação da matriz, reduzindo a penetrabilidade do meio. A escória é também uma das poucas adições que podem ser incorporadas no cimento Portand branco (CPB), que vem se tornando uma nova tendência dentro do contexto da construção civil, quando se opta por concreto aparente em obras com forte apelo arquitetônico. Além das vantagens técnicas e ambientais, a substituição do cimento branco por escória possibilita a redução do custo bastante elevado do CPB. Neste estudo, investigou-se a resistência ao sulfato de sódio do CPB com teores de substituição de escória de alto-forno de 0%, 50% e 70%. Também foi investigada uma mistura com 50% de escória ativada quimicamente por Na2SO4 (em teor de 4% em massa do material aglomerante). O desempenho dos cimentos foi avaliado pela exposição de argamassas em solução de 5% de Na2SO4 por dois anos, de acordo com a ASTM C1012/04 e através de análise de DRX, TG/DTA e MEV/EDS em pastas. Para comparação foram investigadas as mesmas misturas compostas com cimento Portland de alta resistência inicial, CPV-ARI. Os resultados mostraram os benefícios do uso da escória em ambos os cimentos, sendo que o acréscimo do seu teor aumentou a resistência ao ataque por sulfatos. A ativação química reduziu a expansão comparativamente às misturas sem ativador. A longo prazo, todas as misturas com o CPB apresentaram menor expansão do que aquelas com CPV-ARI. A análise da microestrutura identificou a etringita e o sulfato de cálcio como os principais produtos de degradação por sulfato de sódio.
23

RESISTIVIDADE ELÉTRICA DE CONCRETOS DE CIMENTO PORTLAND BRANCO E ELEVADOS TEORES DE ESCÓRIA DE ALTO FORNO / ELECTRICAL RESISTIVITY OF WHITE PORTLAND CEMENT CONCRETES AND HIGH BLAST FURNACE SLAG CONTENT

Lübeck, André 03 March 2008 (has links)
The electrical resistivity is an important concrete property that allows evaluating the access facility of aggressive agents before the corrosion process begins and estimates the velocity of the same process after it begun. The electrical resistivity and the oxygen availability are the characteristics that control the corrosion velocity. This work aimed to evaluate the performance of white Portland cement concretes with high blast furnace slag content and chemical activation on the electrical resistivity. Other properties were measured, as axial compressive strength, porosity and specific electrical conductivity of pore solution. Four mixtures were tested, a reference one, only with white Portland cement as binder, a second one, with 50% of blast furnace slag in substitution of cement, other with 70% slag content, and the last one, with 50% of slag and alkaline activation, 4% of Na2SO4. The water/binder ratios were fixed at 0,30, 0,42 and 0,55 for all samples. The electrical resistivity was measured using the four electrode method (Wenner method). The sample age, water/binder ratio and the slag content have an expressive effect over the electrical resistivity, especially because it results in changes of the pore structure. The electrical resistivity grows as the amount of slag increases. The increase of slag amount also results in smaller specific electrical conductivity of pore solution and pore structure refinement. On the other hand, the axial compressive strength decreases as the slag amount increases. The biggest resistivity results were obtained for the mixture with 70% of slag. This mixture showed the best cost/benefit ratio as compressive strength were fixed at 35 and 55 MPa, at 28 days, and 60 MPa, at 91 days. / A resistividade elétrica é uma importante propriedade do concreto por permitir avaliar a facilidade de acesso de agentes agressivos antes de instalado o processo corrosivo e estimar a velocidade do mesmo depois de instalado, sendo conjuntamente com a disponibilidade de oxigênio um dos parâmetros determinantes para a velocidade da corrosão. Este trabalho teve como objetivo avaliar o desempenho de concretos de cimento Portland branco com elevados teores de escória de alto forno e ativação química quanto à resistividade elétrica aparente. Foram avaliadas além da resistividade outras grandezas como resistência à compressão, porosidade e condutividade específica da solução dos poros. Foram investigadas quatro misturas, uma de referência contendo apenas cimento, uma segunda com teor de substituição de cimento por escória de 50%, outra com teor de substituição de 70% e uma última contendo 50% de escória e ativador alcalino, Na2SO4, em um teor de 4%. As relações água/aglomerante foram fixadas em 0,30, 0,42 e 0,55 para todas as misturas. A medida da resistividade elétrica foi realizada através do método dos quatro eletrodos (Wenner). A resistividade elétrica se mostrou dependente da idade, relação a/ag e teor de escória, principalmente, em função das alterações que estas proporcionam na estrutura de poros da pasta. A resistividade cresceu proporcionalmente ao aumento do teor de escória. O aumento do teor de escória resultou também em menor condutividade da solução aquosa e refinamento da estrutura de poros da pasta. Por outro lado, a resistência à compressão diminuiu com o crescimento do teor de escória. Os maiores valores de resistividade elétrica foram apresentados pela mistura contendo 70% de escória. Esta mistura se mostrou a de melhor relação custo/benefício quando se fixaram valores de resistência à compressão de 35 e 55 MPa, aos 28 dias, e 60 MPa, aos 91 dias.

Page generated in 0.1048 seconds