The Effect of Particle Surface Area to Volume Ratio on Ion Release from CoCr SpheresGrandfield, Darin J 01 June 2009 (has links)
In 2005, over 200,000 Americans underwent a hip arthroplasty, the replacement of a hip joint with an artificial prosthesis. Of these arthroplasties, metal-on-metal type implants represent an increasing usage percentage. Metal-on-metal implants are selected largely for their low volumetric wear rate, durability, and resistance to corrosion. In spite of these advantages, little is known concerning the long-term consequences of heavy metal alloy use in the body, although early research indicates potentially carcinogenic results. This thesis is a preliminary investigation into these long term effects and their root causes.
An improved comprehension of the corrosion kinetics and the rate of ion production from the high surface energy wear debris released by implant articulation can assist in illustrating the relative clinical significance of exposure to these metallic bodies over time. This thesis primarily focuses on developing a test methodology for the detection and analysis of ion dissociation in simulated body fluids. In order to validate this test methodology, the ion dissociation rates and surface characteristics of several predetermined diameters of cobalt chromium alloy spherical particles were analyzed.
The effect of changing particle diameter, and thus surface area to volume ratio, on ion dissociation rate was determined to be significant when not affected by localized agglomeration. Additionally, preferential corrosion of cobalt within individual grains was observed and correlated to elevated cobalt concentrations in the electrolyte. These results suggest that ion dissociation kinetics for true wear particles can be determined through the refinement and application of the methodology developed.
|
2 |
Corrosion Dynamics of Cobalt-Chromium Alloy F-75 PowderTong, Tedman 01 August 2010 (has links)
The increasing usage of metal-on-metal joint replacements consisting of a cobalt-chromium-molybdenum alloy requires increasing concern regarding the inevitable generation of metallic wear debris. Patients with these joint replacements exhibit elevated concentrations of cobalt and chromium ions within their serum, blood and urine. The presence of these metal ions suggests the potential for bodily damage and indicates corrosive processes are acting upon wear debris.
To understand the behavior of these corrosive processes, powders of cobalt-chromium-molybdenum alloy F-75 were studied. Four powder sizes (44, 74, 105, and 420 µm diameter) were subjected to Hank’s Balanced Salt Solution (HBSS) for a 42 day immersion test within an incubating shaker set at 37°C. Samples were removed periodically and analyzed for cobalt and chromium content using Inductive Coupled Plasma – Optical Emission Spectroscopy (ICP-OES). The resulting data gathered allowed for an evaluation of the corrosion rate as a function of particle diameter and exposure duration.
Two observations were noted from the results. First, cobalt concentration (no chromium was detected) increased as a logarithmic function of time. For the 44, 105, and 420 µm diameter powders, cobalt concentration increased rapidly within four days of exposure but corrosion reached a plateau afterwards. The development of an oxide layer that inhibited further corrosion was the cause for this behavior. Second, the cobalt concentration reached a different upper limit depending on the particle diameter. For the 44, 105, and 420 µm diameter powders, samples reached average limits of 0.0611, 0.0314, and 0.0291 ppm Co, respectively. This observation can be related to the increase in particle surface area as diameter decreases within a given volume of particles.
Modeling of this data resulted in empirical relationships for cobalt concentration and corrosion rate as a function of time, and particle diameter or surface area. However, these relationships were not reliably accurate in predicting the results of external corrosion studies on submicron cobalt-chromium particles. Consequently, this model of particle corrosion does not predict what may occur with nano-scale particles.
|
3 |
Efeito de pastilhas higienizadoras efervescentes nos componentes da prótese parcial removível / Effect of effervescent denture tablets on the components of partial removable dentureVasconcelos, Glenda Lara Lopes 09 February 2018 (has links)
Este estudo avaliou os efeitos de pastilhas efervescentes na superfície de liga de cobalto cromo (Co-Cr) e resina termopolimerizável, simulando um período de até 5 anos de imersão, como também analisar sua ação antimicrobiana. A partir de uma matriz metálica, padrões de cera circulares (12 x 3 mm) foram obtidos e fundidos em liga de Co-Cr (DeguDent®). As amostras foram imersas em: Polident 3 minutes® (P3M), Steradent® (St), Polident for Partials® (PP), Efferdent® (Ef), Corega Tabs® (CT), Nitradine® (Ni), Fixodent® (Fi) e Kukident® (K). Foi avaliada a resistência à corrosão (Ecorr, Ipass) (n=5) por meio do Potenciostato/Galvanostato. Foram realizadas análises qualitativas complementares com Microscópio Eletrônico de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS). Após o ensaio de corrosão, cada disco metálico foi incluído em mufla preparada por matrizes circulares de cera (20 x 5 mm), incorporando-o à resina acrílica termopolimerizável (Clássico Ltda®). Os grupos das 4 pastilhas que apresentaram a menor taxa de corrosão e da água destilada (controle) (n=9) foram analisados quanto à rugosidade da superfície metálica e da resina acrílica (Sa, µm) por meio de microscopia confocal a laser. Foram avaliadas a alteração de cor (ΔE) da resina por meio de espectrocolorímetro no início e após a simulação de ½, 1, 2, 3, 4 e 5 anos e alteração de massa (g), no início e final, em balança de alta precisão. Para avaliação antimicrobiana, por meio da contagem de Unidades Formadoras de Colônia (UFC/mL), os espécimes mistos foram contaminados com biofilme misto composto por: S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) e C. glabrata (Cg) e, posteriormente, imersos nas soluções higienizadoras, onde foram semeados em meios específicos para contagem das UFC. De acordo com os resultados obtidos (α=0,05), P3M causou a menor taxa de corrosão e Ni, o menor potencial de corrosão. Com o MEV, verificou-se evidenciação da microestrutura da liga metálica. Quanto à rugosidade superficial do metal, CT (p=0,009) e Ni (p=0,036) causaram aumento na rugosidade em relação ao tempo (Friedman). Na resina, houve aumento da rugosidade após 5 anos (p<0,01). Entre as soluções (Kruskal-Wallis), não houve diferença para ambos os materiais. Não houve diferença na cor da resina acrílica, tanto em relação às soluções (Kruskal Wallis) quanto aos tempos (Friedman). Não foram observadas alterações de massa (Kruskal-Wallis). Quanto à ação antimicrobiana (Kruskal-Wallis), Ni propiciou redução de UFC de Sm (p=0,001). Conclui-se que, embora todas as pastilhas efervescentes não tenham alterado a superfície do metal e da resina acrílica de maneira significativa, nenhuma apresentou ação antimicrobiana contra os microrganismos avaliados do biofilme misto; somente Ni reduziu a quantidade de S. mutans / The aim of this study were: to evaluate the effects of denture cleansers on the surface of cobalt chromium (Co-Cr) and heat-polymerized acrylic resin, simulating a period until 5 years of immersion, as well as to analyze its antimicrobial action. From a metal matrix, disc-shaped wax patterns (12 x 3 mm) were made and later were casting in Co-Cr alloy (DeguDent™). The specimes were immersed in: Polident 3 minutes™ (P3M), Steradent™ (St), Polident for Partials™ (PP), Efferdent™ (Ef), Corega Tabs™ (CT), Nitradine™ (Ni), Fixodent™ (Fi) and Kukident™ (K). The corrosion resistance (Ecorr, Ipass) (n = 5) was evaluated by Potentiostat / Galvanostat. Further qualitative analyzes were performed with scanning electronic microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). After the corrosion test, each metal disk was included in heat-cured acrylic resin (Clássico Ltda™) using moulds previously prepared from circular wax matrices (20 x 5 mm). The four dentures cleansers with the lowest corrosive potential were analyzed for surface roughness of the metal and acrylic resin (Sa, µm) by laser confocal microscopy. The color change (ΔE) of the resin was evaluated by means of a spectrocolorimeter at the beginning and after the simulation of ½, 1, 2, 3, 4 and 5 years and mass change (g), at the beginning and end, in high-precision balance. For antimicrobial evaluation, the mixed specimens (n = 9) were contaminated with multispecies biofilm [S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) and C. glabrata (Cg)] and subsquently immersed in denture cleansers, where they were seeded in specific CFU / mL media. According to the results obtained (α=0.05), there was a significant difference: P3M presented the lowest corrosion rate and Ni, the lowest corrosion potential. According to SEM, the tablets effervescent provided evidence of the microstructure of the alloy. As for the surface roughness in the metal surface, CT (p = 0.009) and Ni (p = 0.036) showed increase in roughness in relation to time (Friedman). At the resin surface, the roughness growed after 5 years. Among the solutions (Kruskal-Wallis), there was no difference for both materials. There was no difference in the color of the acrylic resin (δE), both for solution (Kruskal-Wallis), and for time (Friedman). Differences in weight weren\'t observed (Kruskal-Wallis). In antimicrobial action (Kruskal-Wallis), Ni group showed significant reduction for Sm (p=0.001). It\'s concluded that, although all the denture cleansers didn\'t significantly changed the surface of the metal and acrylic resin, none showed antimicrobial action against the evaluated microorganisms of the mixed biofilm; only Ni reduced the amount of S. mutans
|
4 |
Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloysVasconcelos, Glenda Lara Lopes 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (μm) apresentou-se não normal. Foi utilizada estatística não-paramétrica (α=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (μg/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (α=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes™, Steradent™, Efferdent™, Polident for Partials™ and Corega Tabs™. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (α = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
|
5 |
Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloysGlenda Lara Lopes Vasconcelos 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (μm) apresentou-se não normal. Foi utilizada estatística não-paramétrica (α=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (μg/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (α=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes™, Steradent™, Efferdent™, Polident for Partials™ and Corega Tabs™. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (α = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
|
6 |
Análise da ação antimicrobiana de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio em superfície de liga metálica de cobalto-cromo / Antimicrobial action of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride in cobalt chromium surfaceRaile, Priscilla Neves 25 January 2017 (has links)
A ação antimicrobiana de soluções higienizadoras e um aspecto importante a ser avaliado para sua indicação como método associado a escovação, para higienização de Próteses Parciais Removíveis (PPRs). Este estudo avaliou, por meio de metodologia in vitro, a capacidade de soluções higienizadoras em reduzir as unidades formadoras de colônia (UFC) de biofilmes formados sobre a superfície da liga de cobalto cromo (Co-Cr). 240 espécimes metálicos de Co- Cr circulares (12 mm x 3 mm) foram obtidos de padrões de cera confeccionados a partir de uma matriz metálica. Após fundição, os espécimes foram polidos de forma padronizada e esterilizados por oxido de etileno. Divididos aleatoriamente, os espécimes (n=9) foram contaminados com: Candida albicans (Ca), Candida glabrata (Cg), Streptococcus mutans (Sm) ou Staphylococcus aureus (Sa) e biofilme multiespecies (BM), o qual continha todos os microrganismos estudados. A adesão dos microrganismos ocorreu em 1 hora e 30 minutos em estufa incubadora a 37°C. A maturação do biofilme foi obtida em 48 horas, com troca de meio após 24 horas, também a 37°C, sendo que para Sm e BM o processo ocorreu em microaerofilia. Os espécimes contaminados foram imersos em Ricinus communis a 2% (Rc 2%- 20 min), Ricinus communis a 10% (Rc 10%- 20 min), cloreto de cetilpiridinio a 0,05% (Cepacol) (CPC- 10 min), pastilhas efervescentes (NitrAdine) (NA-15 min) e água destilada (AD- 20 min). Após as imersões, os espécimes foram colocados em meio Leethen Broth e agitados para desprendimento das células viáveis. As suspensões obtidas foram diluídas seriadamente (100, 10-1, 10-2, 10-3) e semeadas em meios específicos para contagem das UFC/mL. A partir dos valores de UFC foram calculados os valores de Log10(UFC+1) para análise estatística (α=0,05). A distribuição dos dados para Sa, Sm em culturas isoladas e para os microrganismos do biofilme multiespécies apresentou-se não normal, tendo sido utilizado o teste de Kruskal-Wallis, seguido pelo teste de Dunn. Para Ca e Cg, a distribuição dos dados apresentou-se normal, tendo sido utilizados ANOVA e teste de Tukey. Em biofilmes isolados, os resultados mostraram eficiência do NA na redução de Cg (p=0,001), Sa (p=0,012) e Sm (p=0,002). Nenhuma das soluções apresentou redução significante de Ca. Dentro do grupo BM, CPC (p=0,035) e NA (p=0,006) reduziram UFC/mL de Cg. NA (p=0,01) foi eficaz contra Sm e nenhuma das soluções apresentou redução de Ca e Sa. Conclui-se que o peróxido alcalino foi o higienizador mais efetivo em relação a maioria dos microrganismos avaliados, mas nenhuma solução apresentou ação contra Ca em superfícies metálicas de Co-Cr. / The evaluation of antimicrobial action of denture cleansers is an important aspect to be investigated to able a denture cleanser to be associated with mechanical method and used to clean removable partial dentures (RPD). This study analyzed in vitro antimicrobial action of cleanser solutions on cobalt chromium (Co-Cr) alloy, reducing the Colony Forming Units (CFU) on biofilms. The specimens (n=240) were obtained from wax patterns (12 mm x 3 mm), made in a metal matrix. Specimens were polished in a standard way and sterilized with ethylene oxide. Randomly divided, the specimens were contaminated with suspension of Candida albicans (Ca), Candida glabrata (Cg), Staphylococcus aureus (Sa), Streptococcus mutans (Sm) and multispecies biofilm (MB), with contained all the microorganisms. The adhesion of microorganisms occurred in 1 hour and 30 minutes in an incubator oven at 37°C. The biofilm growth occurred on 48 hours, with medium change every 24 hours, also at 37°C, while Sm and MB process occurred in microaerophilic. Contaminated specimens were immersed in solutions as the following groups (n=9): A- experimental solution of Ricinus communis 2% (Rc 2%- 20 min.); B- experimental solution of Ricinus communis 10% (Rc 10%- 20 min.); Ccetylpyridiniun chloride 0.500 mg - Cepacol (CPC- 10 min.); D- effervescent tablet - Nitradine (NA- 15 min.); E- distilled water (DW- 20 min.). The specimens were immersed in medium Letheen from which were obtained aliquots. The aliquots were diluted, in 100, 10-1, 10-2 and 10-3, then seeded to determine the number of CFU/ mL. From the CFU values, were calculated values of Log10(CFU+1) for statistical analysis (α=0,05). The distribution of data was observed in isolated Sa, Sm and all the groups of microorganisms in MB was not-normal. In this case, data were processed and Kruskal-Wallis test (α = 0.05) followed by Dunn\'s post test were used. In isolated biofilm of Ca e Sa, data presented normal distribution, so ANOVA followed by Tukey post test were used. In isolated biofilms, AP promoted significant reduction of CFU/mL of Cg (p=0.001), Sa (p=0.012), and Sm (p=0.002). None of the solutions presented difference statistic significant of Ca. In MB group, CPC (p=0.035) and AP (p=0.006) significantly reduced CFU/ml of Cg, and AP (p=0.01) of Sm, none of the solutions presented difference of Ca and Sa. It was concluded that alkaline peroxide was the most effective cleanser in reducing the number of CFU in the most of microorganisms, but no one was effective against Ca in Co-Cr metallic surfaces.
|
7 |
Análise da ação antimicrobiana de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio em superfície de liga metálica de cobalto-cromo / Antimicrobial action of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride in cobalt chromium surfacePriscilla Neves Raile 25 January 2017 (has links)
A ação antimicrobiana de soluções higienizadoras e um aspecto importante a ser avaliado para sua indicação como método associado a escovação, para higienização de Próteses Parciais Removíveis (PPRs). Este estudo avaliou, por meio de metodologia in vitro, a capacidade de soluções higienizadoras em reduzir as unidades formadoras de colônia (UFC) de biofilmes formados sobre a superfície da liga de cobalto cromo (Co-Cr). 240 espécimes metálicos de Co- Cr circulares (12 mm x 3 mm) foram obtidos de padrões de cera confeccionados a partir de uma matriz metálica. Após fundição, os espécimes foram polidos de forma padronizada e esterilizados por oxido de etileno. Divididos aleatoriamente, os espécimes (n=9) foram contaminados com: Candida albicans (Ca), Candida glabrata (Cg), Streptococcus mutans (Sm) ou Staphylococcus aureus (Sa) e biofilme multiespecies (BM), o qual continha todos os microrganismos estudados. A adesão dos microrganismos ocorreu em 1 hora e 30 minutos em estufa incubadora a 37°C. A maturação do biofilme foi obtida em 48 horas, com troca de meio após 24 horas, também a 37°C, sendo que para Sm e BM o processo ocorreu em microaerofilia. Os espécimes contaminados foram imersos em Ricinus communis a 2% (Rc 2%- 20 min), Ricinus communis a 10% (Rc 10%- 20 min), cloreto de cetilpiridinio a 0,05% (Cepacol) (CPC- 10 min), pastilhas efervescentes (NitrAdine) (NA-15 min) e água destilada (AD- 20 min). Após as imersões, os espécimes foram colocados em meio Leethen Broth e agitados para desprendimento das células viáveis. As suspensões obtidas foram diluídas seriadamente (100, 10-1, 10-2, 10-3) e semeadas em meios específicos para contagem das UFC/mL. A partir dos valores de UFC foram calculados os valores de Log10(UFC+1) para análise estatística (α=0,05). A distribuição dos dados para Sa, Sm em culturas isoladas e para os microrganismos do biofilme multiespécies apresentou-se não normal, tendo sido utilizado o teste de Kruskal-Wallis, seguido pelo teste de Dunn. Para Ca e Cg, a distribuição dos dados apresentou-se normal, tendo sido utilizados ANOVA e teste de Tukey. Em biofilmes isolados, os resultados mostraram eficiência do NA na redução de Cg (p=0,001), Sa (p=0,012) e Sm (p=0,002). Nenhuma das soluções apresentou redução significante de Ca. Dentro do grupo BM, CPC (p=0,035) e NA (p=0,006) reduziram UFC/mL de Cg. NA (p=0,01) foi eficaz contra Sm e nenhuma das soluções apresentou redução de Ca e Sa. Conclui-se que o peróxido alcalino foi o higienizador mais efetivo em relação a maioria dos microrganismos avaliados, mas nenhuma solução apresentou ação contra Ca em superfícies metálicas de Co-Cr. / The evaluation of antimicrobial action of denture cleansers is an important aspect to be investigated to able a denture cleanser to be associated with mechanical method and used to clean removable partial dentures (RPD). This study analyzed in vitro antimicrobial action of cleanser solutions on cobalt chromium (Co-Cr) alloy, reducing the Colony Forming Units (CFU) on biofilms. The specimens (n=240) were obtained from wax patterns (12 mm x 3 mm), made in a metal matrix. Specimens were polished in a standard way and sterilized with ethylene oxide. Randomly divided, the specimens were contaminated with suspension of Candida albicans (Ca), Candida glabrata (Cg), Staphylococcus aureus (Sa), Streptococcus mutans (Sm) and multispecies biofilm (MB), with contained all the microorganisms. The adhesion of microorganisms occurred in 1 hour and 30 minutes in an incubator oven at 37°C. The biofilm growth occurred on 48 hours, with medium change every 24 hours, also at 37°C, while Sm and MB process occurred in microaerophilic. Contaminated specimens were immersed in solutions as the following groups (n=9): A- experimental solution of Ricinus communis 2% (Rc 2%- 20 min.); B- experimental solution of Ricinus communis 10% (Rc 10%- 20 min.); Ccetylpyridiniun chloride 0.500 mg - Cepacol (CPC- 10 min.); D- effervescent tablet - Nitradine (NA- 15 min.); E- distilled water (DW- 20 min.). The specimens were immersed in medium Letheen from which were obtained aliquots. The aliquots were diluted, in 100, 10-1, 10-2 and 10-3, then seeded to determine the number of CFU/ mL. From the CFU values, were calculated values of Log10(CFU+1) for statistical analysis (α=0,05). The distribution of data was observed in isolated Sa, Sm and all the groups of microorganisms in MB was not-normal. In this case, data were processed and Kruskal-Wallis test (α = 0.05) followed by Dunn\'s post test were used. In isolated biofilm of Ca e Sa, data presented normal distribution, so ANOVA followed by Tukey post test were used. In isolated biofilms, AP promoted significant reduction of CFU/mL of Cg (p=0.001), Sa (p=0.012), and Sm (p=0.002). None of the solutions presented difference statistic significant of Ca. In MB group, CPC (p=0.035) and AP (p=0.006) significantly reduced CFU/ml of Cg, and AP (p=0.01) of Sm, none of the solutions presented difference of Ca and Sa. It was concluded that alkaline peroxide was the most effective cleanser in reducing the number of CFU in the most of microorganisms, but no one was effective against Ca in Co-Cr metallic surfaces.
|
8 |
EFEITO DA IMERSÃO PERIÓDICA EM SOLUÇÕES LIMPADORAS NA RUGOSIDADE SUPERFICIAL, PORCENTAGEM DE VARIAÇÃO DE MASSA E RESISTÊNCIA FLEXURAL DE LIGAS DE COBALTO-CROMO / Co-Cr ALLOY IMMERSION IN CLEANING SOLUTIONS: EFFECTS ON FLEXURAL STRENGTH, SURFACE ROUGHNESS AND PERCENTUAL OF VARIATION OF MASSBorsa, Pedro Carlos Cortiana 22 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the flexural strength, elastic modulus,
mass changes and surface roughness of two cobalt-chromium alloys, before and
after immersions in four cleaning solutions and distilled water (as control). Co-Cr
alloys (Co-Cr®, Dentsply-DeguDent Industria e Comércio, São Paulo, Brasil; and GM
800+®, Dentaurum GmbH & Co KG, Ispringen, Alemanha) were investigated. Fifty
bar specimens (25 x 3 x 0,5 mm) for the flexural test, 50 quadrangular specimens
(10 x 10 x 1 mm) for mass changes evaluation and 35 cylindrical specimens (10 x 1
mm) for surface roughness measurements were obtained by casting. They were
polished by abrasive paper (#240 to #2500) and diamond polishing paste (3μm).
Specimens were randomly divided into 5 groups according the following cleaning,
solutions: pure white vinegar, 0.2% peracetic acid, sodium perborate - Corega
Tabs®, 0.37% sodium hypochlorite and the control, distilled water. Surface
roughness (Ra parameter) was analyzed using a profilometer (Mitutoyo SJ 410,
Mitutoyo Corp, Kanagawa, Japan) before and after 5, 20 e 90 immersions (10 min
each). Ra changes (ΔRa5, ΔRa20 e ΔRa90) were calculated for the different
intervals. Qualitative surface analyses were performed by Scanning Electron
Microscope (JSM 6360 SEM, JEOL). Both alloys, immersed in pure white vinegar,
0.2% peracetic acid, sodium perborate - Corega Tabs®, 0.37% sodium hypochlorite
had similar roughness changes after 90 immersions (ΔRa from -0,012 to 0,022 μm).
There was a significant surface roughening in hypochlorite (ΔRa90= 0,064 μm for
CoCr®; and ΔRa90 = 0,592 μm for GM 800+). The number of immersions influenced
on the roughness changes only in hypochlorite and there were greater changes in
the GM 800+ alloy. After 90 immersions, GM 800+ alloy showed mass lost in the
hypochlorite solution (-0,3%). This alloy presented higher flexural strength after 90
immersions in SH (σF= 1516 MPa in hypochlorite; 1366 MPa in control). However,
there were no elastic modulus changes. CoCr® alloy did not present differences in
the σF or in elastic modulus in any solution. The only solution that damaged the alloy
surface was 0.37% sodium hypochlorite. / O objetivo deste trabalho foi avaliar a rugosidade superficial,o percentual de variação
de massa, a resistência flexural e o módulo de elasticidade de duas ligas de Cobalto-Cromo
após submetidas à imersões em quatro soluções limpadoras e água (controle). Foram
utilizadas as ligas Co-Cr® DeguDent (Dentsply-DeguDent Industria e Comércio, São
Paulo, Brasil) e Remanium® GM 800+ (Dentaurum GmbH & Co KG, Ispringen, Alemanha).
De cada liga fundiu-se cinquenta corpos de prova, 50 cilíndricos (10 x 1 mm) para a análise
da rugosidade, 50 quadrangulares (10 x 10 x 1 mm) para avaliação da variação de massa e
em formato retangular (25 x 2,5 x 0,75 mm) para o teste flexão 3 pontos. O polimento se deu
por seqüencia de lixas (#400 a 2500) e pasta diamantada (3μm). A distribuição aleatória foi
em 5 grupos, conforme os agentes de limpeza: vinagre branco puro, ácido peracético 0,2% ,
perborato de sódio (Corega Tabs®), hipoclorito de sódio 0,37% e o controle: água destilada.
Foram realizadas avaliações da rugosidade superficial (Parâmetro Ra) através de
rugosímetro (Mitutoyo SJ 410, Mitutoyo Corp, Kanagawa, Japan) antes e após 5, 20 e 90
ciclos de imersão de 10 minutos. As alterações de Ra (ΔRa5, ΔRa20 e ΔRa90) foram
calculadas entre os diferentes interrupções. Análise complementar da superfície foi realizada
em imagens obtidas por microscopia eletrônica de varredura (JSM 6360 SEM, JEOL Ltd.,
Tokyo, Japan). A pesagens dos corpos de prova para cálculo da variação de massa se deu
após 5 e 90 imersões, utilizando-se de balança eletrônica analítica com sensibilidade de
0,0001 g (FA 2004, Coleman E. P. L. Com. e Imp. Ltda. Santo André, São Paulo). Os
ensaios de flexão a 3 pontos para determinação da resistência flexural (σF) e do módulo de
elasticidade foram realizados após 90 imersões. Os dados obtitos foram analisados quanto
a normalidade e testes de comparação entre médias foram aplicados conforme o tipo de
distribuição. As duas ligas, imersas nas soluções vinagre puro, ácido peracético, corega
tabs® apresentaram comportamento semelhante em relação as alterações de rugosidade
superficial (Ra), quando comparadas ao controle, após 90 imersões (ΔRa entre -0,012 e
0,022 μm). Aumento da rugosidade significativo ocorreu na solução de hipoclorito (ΔRa90=
0,064 μm (CoCr®) e 0,592 μm (GM 800+). O número de imersões influenciou na variação de
rugosidade, apenas para a solução de hipoclorito, sendo que as maiores variações
ocorreram na liga GM 800+. Após 90 imersões a liga GM 800+ demonstrou perda de massa
na solução de hipoclorito (-0,3%). Ocorrendo para essa liga aumento da resistência flexural
(σF= 1516 MPa em hipoclorito; 1366 MPa no controle) após 90 imersões, sem modificação
de seu módulo de elasticidade. A liga CoCr® não apresentou diferenças na σF ou no
módulo de elasticidade nas diferentes soluções. A única solução que causou dano à
superfície das ligas foi o hipoclorito de sódio 0,37%.
|