• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 3
  • Tagged with
  • 20
  • 20
  • 12
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys

Glenda Lara Lopes Vasconcelos 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (μm) apresentou-se não normal. Foi utilizada estatística não-paramétrica (α=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (μg/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (α=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes™, Steradent™, Efferdent™, Polident for Partials™ and Corega Tabs™. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (α = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.
12

Análise da ação antimicrobiana de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio em superfície de liga metálica de cobalto-cromo / Antimicrobial action of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride in cobalt chromium surface

Raile, Priscilla Neves 25 January 2017 (has links)
A ação antimicrobiana de soluções higienizadoras e um aspecto importante a ser avaliado para sua indicação como método associado a escovação, para higienização de Próteses Parciais Removíveis (PPRs). Este estudo avaliou, por meio de metodologia in vitro, a capacidade de soluções higienizadoras em reduzir as unidades formadoras de colônia (UFC) de biofilmes formados sobre a superfície da liga de cobalto cromo (Co-Cr). 240 espécimes metálicos de Co- Cr circulares (12 mm x 3 mm) foram obtidos de padrões de cera confeccionados a partir de uma matriz metálica. Após fundição, os espécimes foram polidos de forma padronizada e esterilizados por oxido de etileno. Divididos aleatoriamente, os espécimes (n=9) foram contaminados com: Candida albicans (Ca), Candida glabrata (Cg), Streptococcus mutans (Sm) ou Staphylococcus aureus (Sa) e biofilme multiespecies (BM), o qual continha todos os microrganismos estudados. A adesão dos microrganismos ocorreu em 1 hora e 30 minutos em estufa incubadora a 37°C. A maturação do biofilme foi obtida em 48 horas, com troca de meio após 24 horas, também a 37°C, sendo que para Sm e BM o processo ocorreu em microaerofilia. Os espécimes contaminados foram imersos em Ricinus communis a 2% (Rc 2%- 20 min), Ricinus communis a 10% (Rc 10%- 20 min), cloreto de cetilpiridinio a 0,05% (Cepacol) (CPC- 10 min), pastilhas efervescentes (NitrAdine) (NA-15 min) e água destilada (AD- 20 min). Após as imersões, os espécimes foram colocados em meio Leethen Broth e agitados para desprendimento das células viáveis. As suspensões obtidas foram diluídas seriadamente (100, 10-1, 10-2, 10-3) e semeadas em meios específicos para contagem das UFC/mL. A partir dos valores de UFC foram calculados os valores de Log10(UFC+1) para análise estatística (α=0,05). A distribuição dos dados para Sa, Sm em culturas isoladas e para os microrganismos do biofilme multiespécies apresentou-se não normal, tendo sido utilizado o teste de Kruskal-Wallis, seguido pelo teste de Dunn. Para Ca e Cg, a distribuição dos dados apresentou-se normal, tendo sido utilizados ANOVA e teste de Tukey. Em biofilmes isolados, os resultados mostraram eficiência do NA na redução de Cg (p=0,001), Sa (p=0,012) e Sm (p=0,002). Nenhuma das soluções apresentou redução significante de Ca. Dentro do grupo BM, CPC (p=0,035) e NA (p=0,006) reduziram UFC/mL de Cg. NA (p=0,01) foi eficaz contra Sm e nenhuma das soluções apresentou redução de Ca e Sa. Conclui-se que o peróxido alcalino foi o higienizador mais efetivo em relação a maioria dos microrganismos avaliados, mas nenhuma solução apresentou ação contra Ca em superfícies metálicas de Co-Cr. / The evaluation of antimicrobial action of denture cleansers is an important aspect to be investigated to able a denture cleanser to be associated with mechanical method and used to clean removable partial dentures (RPD). This study analyzed in vitro antimicrobial action of cleanser solutions on cobalt chromium (Co-Cr) alloy, reducing the Colony Forming Units (CFU) on biofilms. The specimens (n=240) were obtained from wax patterns (12 mm x 3 mm), made in a metal matrix. Specimens were polished in a standard way and sterilized with ethylene oxide. Randomly divided, the specimens were contaminated with suspension of Candida albicans (Ca), Candida glabrata (Cg), Staphylococcus aureus (Sa), Streptococcus mutans (Sm) and multispecies biofilm (MB), with contained all the microorganisms. The adhesion of microorganisms occurred in 1 hour and 30 minutes in an incubator oven at 37°C. The biofilm growth occurred on 48 hours, with medium change every 24 hours, also at 37°C, while Sm and MB process occurred in microaerophilic. Contaminated specimens were immersed in solutions as the following groups (n=9): A- experimental solution of Ricinus communis 2% (Rc 2%- 20 min.); B- experimental solution of Ricinus communis 10% (Rc 10%- 20 min.); Ccetylpyridiniun chloride 0.500 mg - Cepacol (CPC- 10 min.); D- effervescent tablet - Nitradine (NA- 15 min.); E- distilled water (DW- 20 min.). The specimens were immersed in medium Letheen from which were obtained aliquots. The aliquots were diluted, in 100, 10-1, 10-2 and 10-3, then seeded to determine the number of CFU/ mL. From the CFU values, were calculated values of Log10(CFU+1) for statistical analysis (α=0,05). The distribution of data was observed in isolated Sa, Sm and all the groups of microorganisms in MB was not-normal. In this case, data were processed and Kruskal-Wallis test (α = 0.05) followed by Dunn\'s post test were used. In isolated biofilm of Ca e Sa, data presented normal distribution, so ANOVA followed by Tukey post test were used. In isolated biofilms, AP promoted significant reduction of CFU/mL of Cg (p=0.001), Sa (p=0.012), and Sm (p=0.002). None of the solutions presented difference statistic significant of Ca. In MB group, CPC (p=0.035) and AP (p=0.006) significantly reduced CFU/ml of Cg, and AP (p=0.01) of Sm, none of the solutions presented difference of Ca and Sa. It was concluded that alkaline peroxide was the most effective cleanser in reducing the number of CFU in the most of microorganisms, but no one was effective against Ca in Co-Cr metallic surfaces.
13

Análise histológica e histomorfométrica de carótidas após o implante de stent de cromocobalto sem e com revestimento de polímero : modelo experimental porcino

Grudtner, Marco Aurelio January 2009 (has links)
Introdução: Apesar dos avanços significativos no tratamento endovascular das doenças arteriais coronarianas e periféricas, a reestenose intra-stent continua sendo o principal limitante a médio prazo desses procedimentos. O mecanismo da reestenose intra-stent é principalmente a hiperplasia intimal, já que o stent impede a retração elástica aguda e resiste ao remodelamento geométrico negativo tardio. A hiperplasia intimal ocorre basicamente em resposta à formação de trombo local, à inflamação e às dissecções intimais e mediais secundárias à injúria causada pelo stent, sendo o grau de resposta intimal a base dos efeitos a longo prazo. O uso de stents com hastes menores e revestidos com drogas ou polímeros tem sido considerado uma nova alternativa para a prevenção da reestenose intra-stent. Objetivo: Analisar a resposta arterial ao implante de stent de cromo-cobalto sem e com revestimento de polímero Camouflage® em artérias carótidas de suínos, utilizando os seguintes parâmetros histológicos: grau de endotelização, conteúdo de células musculares lisas, grau de angiogênese, conteúdo de fibrina, grau de inflamação e injúria; além da análise histomorfométrica. Método: Stents balões-expansíveis de cromo-cobalto ( 8 stents CC Flex e 5 stents CC Flex Proactive) de 4 x 16 mm foram implantados em artérias carótidas comuns de oito suínos jovens, sendo um stent liberado em cada artéria. Após 30 dias, as artérias contendo os stents foram removidas, fixadas e coradas pelos métodos de hematoxilina/eosina e Verhoeff/Van Giesson. O segmento arterial contendo o stent foi dividido em 3 blocos distintos: proximal, médio e distal. Os cortes histológicos foram obtidos utilizando-se micrótomo de impacto (Polycut S, Leica, Alemanha) equipado com navalha de tungstênio de 16 cm, tipo D (Leica, Alemanha), com 5 ^m de espessura. A navalha de tungstênio mantém as hastes dos stents intactas nas secções transversas, minimizando os artefatos potenciais causados pela retirada dos stents. A avaliação foi realizada através de critérios histológicos e histomorfométricos. Resultados: Todos os stents foram implantados com sucesso e sem dificuldades técnicas. A análise histológica em 30 dias evidenciou alto grau de endotelização em todos os segmentos avaliados e leve à moderada infiltração de células musculares na íntima. Observou-se baixo grau de angiogênese em cerca de 50% dos segmentos avaliados e ausência completa de deposição de fibrina em pelo menos 80%, com distribuição semelhante entre os grupos. A resposta inflamatória e o grau de injúria causadas pelas hastes dos stents também foram discretas e similares entre os grupos e não houve correlação entre resposta inflamatória e injúria e desses parâmetros com a área de neoíntima. O grau de obstrução neo-intimal identificada neste período foi pequeno (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive) e estatisticamente não significativo entre os grupos (p=0,785). Conclusão: Os achados deste estudo experimental sugerem que o uso de stents de cromo-cobalto revestidos com polímero Camouflage® em artérias carótidas de suínos parece estar associado, pelo menos no curto prazo, a uma resposta histológica semelhante àquela encontrada após o implante de stents de cromo-cobalto não revestidos. Neste período não se observou uma menor hiperplasia intimal em virtude do revestimento de polímero. / Introduction: Despite all the advances in the endovascular treatment of coronary and peripheral artery diseases, in-stent restenosis is still the main limiting factor of these procedures in the medium and long-term. The mechanism of in-stent restenosis is mainly the intimal hyperplasia, as the stent prevents acute elastic recoil and later negative geometric arterial remodeling. Intimal hyperplasia occurs basically in response to the formation of local thrombus, inflammation and intimal and medial dissections secondary to the injury caused by the stent, with the degree of intimal response being the cause of long-term effects. Coating drug-eluting stents with polymers and drugs with thinner struts have been considered a new alternative for in-stent restenosis prevention. Objective: Analyse the arterial response to the cobalt-chromium stent implant with and without polymer coating Camouflage® in carotid arteries of pigs, using the following histological parameters: degree of endothelialization, smooth muscle cells (SMC) content, degree of angiogenesis, intimal fibrin content, degree of inflammation and injury; plus histomorphometric analysis. Method: Cobaltchromium balloon-expandable stents (8 CC Flex stents and 5 CC Flex Proactive), 4 x 16 mm, were deployed in common carotid arteries of 8 young pigs, with one stent being deployed in each artery. After 30 days, the arteries containing the stents were removed and underwent fixation and staining using the hematoxilin/eosin and Verhoeff /Van Giesson methods. The arterial segment containing the stent was divided into 3 distinct portions: proximal, middle and distal. The histological sections were obtained using impact microtome (Polycut S, Leica, Germany), equipped with a 16 cm, type D, 5 ^m thick tungsten knife (Leica, Germany). The tungsten knife maintains the stent shaft intact in cross sections, minimizing the potential artifacts caused by stent removal. The evaluation was carried out using histological and histomorfometric criteria. Results: All the stents were deployed with success and with no technical difficulties. The histological analysis performed after 30 days showed a high level of endothelialization in all the evaluated portions and mild to moderate infiltration of the SMC in the intima layer. A low level of angiogenesis of about 50% of the evaluated portions was observed and a complete absence of fibrin deposition in at least 80% of the portions, with similar distribution among the groups. The inflammatory response and the level of injury caused by the struts of the stents were also minimum and this was similar among the groups. There was no correlation between inflammatory response and injury and between the two latter parameters and the neo-intima area. The level of neo-intimal obstruction identified in this period was small (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive ) and no statistical significance between the groups (p=0,785). Conclusion: The findings of this experimental study suggest the use of balloonexpandable cobalt-chromium stents coated with polymer Camouflage® in carotid arteries of pigs seems to be associated, at least in the short-term, with a similar histological response to that found in the implantation of non-coated cobalt-chromium stents. In this period, a lower intimal hyperplasia was not observed with polymer coating stents.
14

Análise histológica e histomorfométrica de carótidas após o implante de stent de cromocobalto sem e com revestimento de polímero : modelo experimental porcino

Grudtner, Marco Aurelio January 2009 (has links)
Introdução: Apesar dos avanços significativos no tratamento endovascular das doenças arteriais coronarianas e periféricas, a reestenose intra-stent continua sendo o principal limitante a médio prazo desses procedimentos. O mecanismo da reestenose intra-stent é principalmente a hiperplasia intimal, já que o stent impede a retração elástica aguda e resiste ao remodelamento geométrico negativo tardio. A hiperplasia intimal ocorre basicamente em resposta à formação de trombo local, à inflamação e às dissecções intimais e mediais secundárias à injúria causada pelo stent, sendo o grau de resposta intimal a base dos efeitos a longo prazo. O uso de stents com hastes menores e revestidos com drogas ou polímeros tem sido considerado uma nova alternativa para a prevenção da reestenose intra-stent. Objetivo: Analisar a resposta arterial ao implante de stent de cromo-cobalto sem e com revestimento de polímero Camouflage® em artérias carótidas de suínos, utilizando os seguintes parâmetros histológicos: grau de endotelização, conteúdo de células musculares lisas, grau de angiogênese, conteúdo de fibrina, grau de inflamação e injúria; além da análise histomorfométrica. Método: Stents balões-expansíveis de cromo-cobalto ( 8 stents CC Flex e 5 stents CC Flex Proactive) de 4 x 16 mm foram implantados em artérias carótidas comuns de oito suínos jovens, sendo um stent liberado em cada artéria. Após 30 dias, as artérias contendo os stents foram removidas, fixadas e coradas pelos métodos de hematoxilina/eosina e Verhoeff/Van Giesson. O segmento arterial contendo o stent foi dividido em 3 blocos distintos: proximal, médio e distal. Os cortes histológicos foram obtidos utilizando-se micrótomo de impacto (Polycut S, Leica, Alemanha) equipado com navalha de tungstênio de 16 cm, tipo D (Leica, Alemanha), com 5 ^m de espessura. A navalha de tungstênio mantém as hastes dos stents intactas nas secções transversas, minimizando os artefatos potenciais causados pela retirada dos stents. A avaliação foi realizada através de critérios histológicos e histomorfométricos. Resultados: Todos os stents foram implantados com sucesso e sem dificuldades técnicas. A análise histológica em 30 dias evidenciou alto grau de endotelização em todos os segmentos avaliados e leve à moderada infiltração de células musculares na íntima. Observou-se baixo grau de angiogênese em cerca de 50% dos segmentos avaliados e ausência completa de deposição de fibrina em pelo menos 80%, com distribuição semelhante entre os grupos. A resposta inflamatória e o grau de injúria causadas pelas hastes dos stents também foram discretas e similares entre os grupos e não houve correlação entre resposta inflamatória e injúria e desses parâmetros com a área de neoíntima. O grau de obstrução neo-intimal identificada neste período foi pequeno (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive) e estatisticamente não significativo entre os grupos (p=0,785). Conclusão: Os achados deste estudo experimental sugerem que o uso de stents de cromo-cobalto revestidos com polímero Camouflage® em artérias carótidas de suínos parece estar associado, pelo menos no curto prazo, a uma resposta histológica semelhante àquela encontrada após o implante de stents de cromo-cobalto não revestidos. Neste período não se observou uma menor hiperplasia intimal em virtude do revestimento de polímero. / Introduction: Despite all the advances in the endovascular treatment of coronary and peripheral artery diseases, in-stent restenosis is still the main limiting factor of these procedures in the medium and long-term. The mechanism of in-stent restenosis is mainly the intimal hyperplasia, as the stent prevents acute elastic recoil and later negative geometric arterial remodeling. Intimal hyperplasia occurs basically in response to the formation of local thrombus, inflammation and intimal and medial dissections secondary to the injury caused by the stent, with the degree of intimal response being the cause of long-term effects. Coating drug-eluting stents with polymers and drugs with thinner struts have been considered a new alternative for in-stent restenosis prevention. Objective: Analyse the arterial response to the cobalt-chromium stent implant with and without polymer coating Camouflage® in carotid arteries of pigs, using the following histological parameters: degree of endothelialization, smooth muscle cells (SMC) content, degree of angiogenesis, intimal fibrin content, degree of inflammation and injury; plus histomorphometric analysis. Method: Cobaltchromium balloon-expandable stents (8 CC Flex stents and 5 CC Flex Proactive), 4 x 16 mm, were deployed in common carotid arteries of 8 young pigs, with one stent being deployed in each artery. After 30 days, the arteries containing the stents were removed and underwent fixation and staining using the hematoxilin/eosin and Verhoeff /Van Giesson methods. The arterial segment containing the stent was divided into 3 distinct portions: proximal, middle and distal. The histological sections were obtained using impact microtome (Polycut S, Leica, Germany), equipped with a 16 cm, type D, 5 ^m thick tungsten knife (Leica, Germany). The tungsten knife maintains the stent shaft intact in cross sections, minimizing the potential artifacts caused by stent removal. The evaluation was carried out using histological and histomorfometric criteria. Results: All the stents were deployed with success and with no technical difficulties. The histological analysis performed after 30 days showed a high level of endothelialization in all the evaluated portions and mild to moderate infiltration of the SMC in the intima layer. A low level of angiogenesis of about 50% of the evaluated portions was observed and a complete absence of fibrin deposition in at least 80% of the portions, with similar distribution among the groups. The inflammatory response and the level of injury caused by the struts of the stents were also minimum and this was similar among the groups. There was no correlation between inflammatory response and injury and between the two latter parameters and the neo-intima area. The level of neo-intimal obstruction identified in this period was small (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive ) and no statistical significance between the groups (p=0,785). Conclusion: The findings of this experimental study suggest the use of balloonexpandable cobalt-chromium stents coated with polymer Camouflage® in carotid arteries of pigs seems to be associated, at least in the short-term, with a similar histological response to that found in the implantation of non-coated cobalt-chromium stents. In this period, a lower intimal hyperplasia was not observed with polymer coating stents.
15

Análise histológica e histomorfométrica de carótidas após o implante de stent de cromocobalto sem e com revestimento de polímero : modelo experimental porcino

Grudtner, Marco Aurelio January 2009 (has links)
Introdução: Apesar dos avanços significativos no tratamento endovascular das doenças arteriais coronarianas e periféricas, a reestenose intra-stent continua sendo o principal limitante a médio prazo desses procedimentos. O mecanismo da reestenose intra-stent é principalmente a hiperplasia intimal, já que o stent impede a retração elástica aguda e resiste ao remodelamento geométrico negativo tardio. A hiperplasia intimal ocorre basicamente em resposta à formação de trombo local, à inflamação e às dissecções intimais e mediais secundárias à injúria causada pelo stent, sendo o grau de resposta intimal a base dos efeitos a longo prazo. O uso de stents com hastes menores e revestidos com drogas ou polímeros tem sido considerado uma nova alternativa para a prevenção da reestenose intra-stent. Objetivo: Analisar a resposta arterial ao implante de stent de cromo-cobalto sem e com revestimento de polímero Camouflage® em artérias carótidas de suínos, utilizando os seguintes parâmetros histológicos: grau de endotelização, conteúdo de células musculares lisas, grau de angiogênese, conteúdo de fibrina, grau de inflamação e injúria; além da análise histomorfométrica. Método: Stents balões-expansíveis de cromo-cobalto ( 8 stents CC Flex e 5 stents CC Flex Proactive) de 4 x 16 mm foram implantados em artérias carótidas comuns de oito suínos jovens, sendo um stent liberado em cada artéria. Após 30 dias, as artérias contendo os stents foram removidas, fixadas e coradas pelos métodos de hematoxilina/eosina e Verhoeff/Van Giesson. O segmento arterial contendo o stent foi dividido em 3 blocos distintos: proximal, médio e distal. Os cortes histológicos foram obtidos utilizando-se micrótomo de impacto (Polycut S, Leica, Alemanha) equipado com navalha de tungstênio de 16 cm, tipo D (Leica, Alemanha), com 5 ^m de espessura. A navalha de tungstênio mantém as hastes dos stents intactas nas secções transversas, minimizando os artefatos potenciais causados pela retirada dos stents. A avaliação foi realizada através de critérios histológicos e histomorfométricos. Resultados: Todos os stents foram implantados com sucesso e sem dificuldades técnicas. A análise histológica em 30 dias evidenciou alto grau de endotelização em todos os segmentos avaliados e leve à moderada infiltração de células musculares na íntima. Observou-se baixo grau de angiogênese em cerca de 50% dos segmentos avaliados e ausência completa de deposição de fibrina em pelo menos 80%, com distribuição semelhante entre os grupos. A resposta inflamatória e o grau de injúria causadas pelas hastes dos stents também foram discretas e similares entre os grupos e não houve correlação entre resposta inflamatória e injúria e desses parâmetros com a área de neoíntima. O grau de obstrução neo-intimal identificada neste período foi pequeno (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive) e estatisticamente não significativo entre os grupos (p=0,785). Conclusão: Os achados deste estudo experimental sugerem que o uso de stents de cromo-cobalto revestidos com polímero Camouflage® em artérias carótidas de suínos parece estar associado, pelo menos no curto prazo, a uma resposta histológica semelhante àquela encontrada após o implante de stents de cromo-cobalto não revestidos. Neste período não se observou uma menor hiperplasia intimal em virtude do revestimento de polímero. / Introduction: Despite all the advances in the endovascular treatment of coronary and peripheral artery diseases, in-stent restenosis is still the main limiting factor of these procedures in the medium and long-term. The mechanism of in-stent restenosis is mainly the intimal hyperplasia, as the stent prevents acute elastic recoil and later negative geometric arterial remodeling. Intimal hyperplasia occurs basically in response to the formation of local thrombus, inflammation and intimal and medial dissections secondary to the injury caused by the stent, with the degree of intimal response being the cause of long-term effects. Coating drug-eluting stents with polymers and drugs with thinner struts have been considered a new alternative for in-stent restenosis prevention. Objective: Analyse the arterial response to the cobalt-chromium stent implant with and without polymer coating Camouflage® in carotid arteries of pigs, using the following histological parameters: degree of endothelialization, smooth muscle cells (SMC) content, degree of angiogenesis, intimal fibrin content, degree of inflammation and injury; plus histomorphometric analysis. Method: Cobaltchromium balloon-expandable stents (8 CC Flex stents and 5 CC Flex Proactive), 4 x 16 mm, were deployed in common carotid arteries of 8 young pigs, with one stent being deployed in each artery. After 30 days, the arteries containing the stents were removed and underwent fixation and staining using the hematoxilin/eosin and Verhoeff /Van Giesson methods. The arterial segment containing the stent was divided into 3 distinct portions: proximal, middle and distal. The histological sections were obtained using impact microtome (Polycut S, Leica, Germany), equipped with a 16 cm, type D, 5 ^m thick tungsten knife (Leica, Germany). The tungsten knife maintains the stent shaft intact in cross sections, minimizing the potential artifacts caused by stent removal. The evaluation was carried out using histological and histomorfometric criteria. Results: All the stents were deployed with success and with no technical difficulties. The histological analysis performed after 30 days showed a high level of endothelialization in all the evaluated portions and mild to moderate infiltration of the SMC in the intima layer. A low level of angiogenesis of about 50% of the evaluated portions was observed and a complete absence of fibrin deposition in at least 80% of the portions, with similar distribution among the groups. The inflammatory response and the level of injury caused by the struts of the stents were also minimum and this was similar among the groups. There was no correlation between inflammatory response and injury and between the two latter parameters and the neo-intima area. The level of neo-intimal obstruction identified in this period was small (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive ) and no statistical significance between the groups (p=0,785). Conclusion: The findings of this experimental study suggest the use of balloonexpandable cobalt-chromium stents coated with polymer Camouflage® in carotid arteries of pigs seems to be associated, at least in the short-term, with a similar histological response to that found in the implantation of non-coated cobalt-chromium stents. In this period, a lower intimal hyperplasia was not observed with polymer coating stents.
16

Análise da ação antimicrobiana de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio em superfície de liga metálica de cobalto-cromo / Antimicrobial action of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride in cobalt chromium surface

Priscilla Neves Raile 25 January 2017 (has links)
A ação antimicrobiana de soluções higienizadoras e um aspecto importante a ser avaliado para sua indicação como método associado a escovação, para higienização de Próteses Parciais Removíveis (PPRs). Este estudo avaliou, por meio de metodologia in vitro, a capacidade de soluções higienizadoras em reduzir as unidades formadoras de colônia (UFC) de biofilmes formados sobre a superfície da liga de cobalto cromo (Co-Cr). 240 espécimes metálicos de Co- Cr circulares (12 mm x 3 mm) foram obtidos de padrões de cera confeccionados a partir de uma matriz metálica. Após fundição, os espécimes foram polidos de forma padronizada e esterilizados por oxido de etileno. Divididos aleatoriamente, os espécimes (n=9) foram contaminados com: Candida albicans (Ca), Candida glabrata (Cg), Streptococcus mutans (Sm) ou Staphylococcus aureus (Sa) e biofilme multiespecies (BM), o qual continha todos os microrganismos estudados. A adesão dos microrganismos ocorreu em 1 hora e 30 minutos em estufa incubadora a 37°C. A maturação do biofilme foi obtida em 48 horas, com troca de meio após 24 horas, também a 37°C, sendo que para Sm e BM o processo ocorreu em microaerofilia. Os espécimes contaminados foram imersos em Ricinus communis a 2% (Rc 2%- 20 min), Ricinus communis a 10% (Rc 10%- 20 min), cloreto de cetilpiridinio a 0,05% (Cepacol) (CPC- 10 min), pastilhas efervescentes (NitrAdine) (NA-15 min) e água destilada (AD- 20 min). Após as imersões, os espécimes foram colocados em meio Leethen Broth e agitados para desprendimento das células viáveis. As suspensões obtidas foram diluídas seriadamente (100, 10-1, 10-2, 10-3) e semeadas em meios específicos para contagem das UFC/mL. A partir dos valores de UFC foram calculados os valores de Log10(UFC+1) para análise estatística (α=0,05). A distribuição dos dados para Sa, Sm em culturas isoladas e para os microrganismos do biofilme multiespécies apresentou-se não normal, tendo sido utilizado o teste de Kruskal-Wallis, seguido pelo teste de Dunn. Para Ca e Cg, a distribuição dos dados apresentou-se normal, tendo sido utilizados ANOVA e teste de Tukey. Em biofilmes isolados, os resultados mostraram eficiência do NA na redução de Cg (p=0,001), Sa (p=0,012) e Sm (p=0,002). Nenhuma das soluções apresentou redução significante de Ca. Dentro do grupo BM, CPC (p=0,035) e NA (p=0,006) reduziram UFC/mL de Cg. NA (p=0,01) foi eficaz contra Sm e nenhuma das soluções apresentou redução de Ca e Sa. Conclui-se que o peróxido alcalino foi o higienizador mais efetivo em relação a maioria dos microrganismos avaliados, mas nenhuma solução apresentou ação contra Ca em superfícies metálicas de Co-Cr. / The evaluation of antimicrobial action of denture cleansers is an important aspect to be investigated to able a denture cleanser to be associated with mechanical method and used to clean removable partial dentures (RPD). This study analyzed in vitro antimicrobial action of cleanser solutions on cobalt chromium (Co-Cr) alloy, reducing the Colony Forming Units (CFU) on biofilms. The specimens (n=240) were obtained from wax patterns (12 mm x 3 mm), made in a metal matrix. Specimens were polished in a standard way and sterilized with ethylene oxide. Randomly divided, the specimens were contaminated with suspension of Candida albicans (Ca), Candida glabrata (Cg), Staphylococcus aureus (Sa), Streptococcus mutans (Sm) and multispecies biofilm (MB), with contained all the microorganisms. The adhesion of microorganisms occurred in 1 hour and 30 minutes in an incubator oven at 37°C. The biofilm growth occurred on 48 hours, with medium change every 24 hours, also at 37°C, while Sm and MB process occurred in microaerophilic. Contaminated specimens were immersed in solutions as the following groups (n=9): A- experimental solution of Ricinus communis 2% (Rc 2%- 20 min.); B- experimental solution of Ricinus communis 10% (Rc 10%- 20 min.); Ccetylpyridiniun chloride 0.500 mg - Cepacol (CPC- 10 min.); D- effervescent tablet - Nitradine (NA- 15 min.); E- distilled water (DW- 20 min.). The specimens were immersed in medium Letheen from which were obtained aliquots. The aliquots were diluted, in 100, 10-1, 10-2 and 10-3, then seeded to determine the number of CFU/ mL. From the CFU values, were calculated values of Log10(CFU+1) for statistical analysis (α=0,05). The distribution of data was observed in isolated Sa, Sm and all the groups of microorganisms in MB was not-normal. In this case, data were processed and Kruskal-Wallis test (α = 0.05) followed by Dunn\'s post test were used. In isolated biofilm of Ca e Sa, data presented normal distribution, so ANOVA followed by Tukey post test were used. In isolated biofilms, AP promoted significant reduction of CFU/mL of Cg (p=0.001), Sa (p=0.012), and Sm (p=0.002). None of the solutions presented difference statistic significant of Ca. In MB group, CPC (p=0.035) and AP (p=0.006) significantly reduced CFU/ml of Cg, and AP (p=0.01) of Sm, none of the solutions presented difference of Ca and Sa. It was concluded that alkaline peroxide was the most effective cleanser in reducing the number of CFU in the most of microorganisms, but no one was effective against Ca in Co-Cr metallic surfaces.
17

Efeito de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio na superfície da liga metálica de cobalto cromo / Effect of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride on the surface of the cobalt chromium alloy

Curylofo, Patricia Almeida 24 January 2017 (has links)
A longevidade da prótese e a saúde bucal de usuário de Prótese Parcial Removível (PPR) são muito dependentes de higiene apropriada. O objetivo deste estudo foi comparar o efeito de soluções de Ricinus communis, em diferentes concentrações, com soluções de peróxido alcalino e cloreto de cetilpiridínio, em relação à liga metálica de Cobalto Cromo (Co-Cr) que compõe a estrutura de PPR. A amostra do experimento foi composta por 55 espécimes de Co-Cr, confeccionados a partir de padrões de cera circulares (12 mm x 3 mm) obtidos a partir de uma matriz metálica. Os padrões foram fundidos, numerados aleatoriamente e divididos em 5 grupos de imersão: H2O- água deionizada (controle) (15 minutos); Rc 2%- Ricinus communis 2% (20 minutos), Rc 10% -Ricinus communis 10% (20 minutos), PA- peróxido alcalino (15 minutos) e CCP- cloreto de cetilpiridínio 0,500 mg (10 minutos). Os espécimes foram avaliados quanto à rugosidade de superfície (n=10) no início e após a simulação de 6 meses, 1, 2, 3, 4 e 5 anos tanto pelo microscópio confocal a laser (Sa, &micro;m), como também pelo rugosímetro de superfície (Ra, &micro;m). Um espécime de cada grupo foi analisado quanto à topografia de superfície (Microscopia Eletrônica de Varredura, MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS) antes e após simulação de uso por 5 anos. De acordo com os resultados obtidos (&alpha;=0,05) pela microscopia confocal (Sa), não houve diferença para o fator solução (Kruskal-Wallis); para o fator tempo (Friedman) houve diferença estatística em Rc 2% entre T0 e T1, T3, T4 e T6 (p<0,001) e em Rc 10% de T2 para T3 (p=0,007), com diminuição da rugosidade. Com o rugosímetro (Ra), houve diferença estatística (Kruskal- Wallis) para CCP que apresentou menor rugosidade em relação à Rc 10% em T1 (p=0,048) e T6 (p=0,013). Em relação ao tempo (Friedman), a água propiciou diminuição da rugosidade superficial (Ra) de T0 para T2 (p=0,013). Na análise de MEV e EDS podese verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que embora tenha sido encontrada diferença estatística para a rugosidade, os resultados são clínicamentes aceitáveis. Deste modo, todas as soluções podem ser utilizadas com segurança pelo período de 5 anos. / Denture longevity and oral health of Removable Partial Denture (RPD) user are highly dependent on proper hygiene. The aim of this study was to compare the effect of solutions of Ricinus communis, in different concentrations, with solutions of alkaline peroxide and cetylpyridinium chloride 0.500 mg, in relation to the Cobalt Chromium (Co-Cr) alloy that composes the structure of RPD. The sample of the experiment consisted of 55 specimens of Co-Cr, made from circular wax patterns (12 mm x 3 mm) obtained in a metal matrix. The patterns were cast, randomly enumerated and divided into 5 immersion groups: H2Odeionized water (control) (15 minutes); Rc 2%- Ricinus communis 2% (20 minutes), Rc 10% -Ricinus communis 10% (20 minutes), PA-alkaline peroxide (15 minutes) and CCPcetylpyridinium chloride 0.500 mg (10 minutes). The specimens were evaluated for surface roughness (n = 10) at the beginning and after the simulation of 6 months, 1, 2, 3, 4 and 5 years by the laser confocal microscope (Sa, &micro;m) and by the rugosimeter of surface (Ra, &micro;m). One specimen from each group was analyzed for surface topography (Scanning Electron Microscopy, SEM) and Energy-dispersive X-ray spectroscopy (EDS) befofe and after simulation of use for 5 years. According to the results obtained (&alpha;= 0.05) by confocal microscopy (Sa), there was no difference for the solution factor (Kruskal- Wallis); For the time factor (Friedman) there was a statistical difference in Rc 2% in T0 to T1, T3, T4 and T6 (p <0.001) and Rc 10% in T2 to T3 (p = 0.007), with decrease in roughness. With the the rugosimeter (Ra), there was a statistical difference (Kruskal- Wallis) for CCP that presented less roughness in relation to the Rc 10% in T1 (p = 0.048) and T6 (p = 0.013). In relation to the time, (Friedman) the water caused a reduction of surface roughness (Ra) between T0 and T2 (p = 0.013). In the analysis of SEM and EDS it can be verified that the solutions did not present deleterious effects on the surfaces. It was concluded that although a statistical difference was found for roughness, the results are clinically acceptable. Thus, all solutions can be safely used for a period of 5 years.
18

An?lise mec?nica e microestrutural das ligas de cobalto-cromo de uso odontol?gico ap?s sucessivas refundi??es

Dantas, H?rrisson de Almeida 30 May 2008 (has links)
Made available in DSpace on 2014-12-17T14:07:01Z (GMT). No. of bitstreams: 1 HarrisonAD.pdf: 3488100 bytes, checksum: 805801db06d21e5667735d16a5799fe2 (MD5) Previous issue date: 2008-05-30 / The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles / Ligas cobalto-cromo s?o extensivamente utilizadas na Odontologia para a confec??o de arma??es met?licas em pr?teses parciais remov?veis. Durante os ?ltimos anos, tem sido reportado um n?mero crescente de falhas prematuras, com poucos meses de utiliza??o das pr?teses. A fabrica??o desses componentes ? feita em laborat?rios prot?ticos e normalmente envolve a refundi??o, utilizando partes de liga fundida e partes de liga virgem. Portanto, o objetivo do presente estudo foi analisar as propriedades mec?nicas de uma liga comercial de cobalto-cromo de uso odontol?gico ap?s sucessivas refundi??es, buscando informa??es no sentido de orientar os laborat?rios de pr?tese dent?ria na correta manipula??o dessa liga no processo de fundi??o e nos poss?veis limites de refundi??o desse material. Foram confeccionados sete grupos de amostras, cada um contendo cinco corpos de prova, divididos da seguinte maneira: G1: fundi??o apenas com liga virgem; G2: fundi??o com 50% da liga do G1 + 50% de liga virgem; G3: fundi??o com 50% da liga do G2 + 50% de liga virgem; G4: fundi??o com 50% da liga do G3 + 50% de liga virgem; G5: 50% de liga do G4 + 50% de liga virgem; G6: 50% de liga do G5 + 50% de liga virgem e finalmente o G7, s? com liga refundida. Foram avaliadas as principais modifica??es ocorridas no comportamento mec?nico dessa liga por meio de ensaios de tra??o e microdureza. Al?m disso, foi realizada a caracteriza??o microestrutural do material por meio de microscopia ?ptica e eletr?nica de varredura, difra??o e fluoresc?ncia de raios X procurando correlacionar as altera??es mec?nicas com modifica??es estruturais do material ocasionadas pelos sucessivos processos de refundi??o. De forma geral os resultados mostraram altera??es na plasticidade e energia de fratura da liga ap?s sucessivas refundi??es, decorrentes principalmente da crescente presen?a de poros e vazios, defeitos caracter?sticos da fundi??o do material. A interpreta??o dos resultados permitiu concluir que o material n?o apresentou diferen?as significativas em rela??o ? resist?ncia ? tra??o ou ao limite el?stico, em fun??o das sucessivas refundi??es. A energia de fratura do material mostrou tend?ncia ? diminui??o, ? medida que o material foi refundido. Em rela??o ? microdureza, as an?lises estat?sticas mostraram n?o haver diferen?as significativas. A microscopia eletr?nica revelou a presen?a de falhas e defeitos, resultantes dos processos de refundi??es. A an?lise por fluoresc?ncia e difra??o de raios X n?o mostrou altera??es na composi??o da liga ou na forma??o de fases cristalinas entre os grupos analisados. As micrografias ?pticas mostraram um crescente n?mero de vazios e aumento da porosidade ? medida que o material foi refundido. Assim, a conclus?o geral do trabalho ? que as sucessivas refundi??es em ligas de Co-Cr comprometem as propriedades mec?nicas do material, o que pode levar a falhas e consequentemente, ao fracasso do trabalho prot?tico. Com base nos resultados, o mais recomendado ? a utiliza??o de no m?ximo duas refundi??es, para que as propriedades do material n?o sejam comprometidas
19

Efeito de soluções experimentais de Ricinus communis, peróxido alcalino e cloreto de cetilpiridínio na superfície da liga metálica de cobalto cromo / Effect of experimental solutions of Ricinus communis, alkaline peroxide and cetylpyridinium chloride on the surface of the cobalt chromium alloy

Patricia Almeida Curylofo 24 January 2017 (has links)
A longevidade da prótese e a saúde bucal de usuário de Prótese Parcial Removível (PPR) são muito dependentes de higiene apropriada. O objetivo deste estudo foi comparar o efeito de soluções de Ricinus communis, em diferentes concentrações, com soluções de peróxido alcalino e cloreto de cetilpiridínio, em relação à liga metálica de Cobalto Cromo (Co-Cr) que compõe a estrutura de PPR. A amostra do experimento foi composta por 55 espécimes de Co-Cr, confeccionados a partir de padrões de cera circulares (12 mm x 3 mm) obtidos a partir de uma matriz metálica. Os padrões foram fundidos, numerados aleatoriamente e divididos em 5 grupos de imersão: H2O- água deionizada (controle) (15 minutos); Rc 2%- Ricinus communis 2% (20 minutos), Rc 10% -Ricinus communis 10% (20 minutos), PA- peróxido alcalino (15 minutos) e CCP- cloreto de cetilpiridínio 0,500 mg (10 minutos). Os espécimes foram avaliados quanto à rugosidade de superfície (n=10) no início e após a simulação de 6 meses, 1, 2, 3, 4 e 5 anos tanto pelo microscópio confocal a laser (Sa, &micro;m), como também pelo rugosímetro de superfície (Ra, &micro;m). Um espécime de cada grupo foi analisado quanto à topografia de superfície (Microscopia Eletrônica de Varredura, MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS) antes e após simulação de uso por 5 anos. De acordo com os resultados obtidos (&alpha;=0,05) pela microscopia confocal (Sa), não houve diferença para o fator solução (Kruskal-Wallis); para o fator tempo (Friedman) houve diferença estatística em Rc 2% entre T0 e T1, T3, T4 e T6 (p<0,001) e em Rc 10% de T2 para T3 (p=0,007), com diminuição da rugosidade. Com o rugosímetro (Ra), houve diferença estatística (Kruskal- Wallis) para CCP que apresentou menor rugosidade em relação à Rc 10% em T1 (p=0,048) e T6 (p=0,013). Em relação ao tempo (Friedman), a água propiciou diminuição da rugosidade superficial (Ra) de T0 para T2 (p=0,013). Na análise de MEV e EDS podese verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que embora tenha sido encontrada diferença estatística para a rugosidade, os resultados são clínicamentes aceitáveis. Deste modo, todas as soluções podem ser utilizadas com segurança pelo período de 5 anos. / Denture longevity and oral health of Removable Partial Denture (RPD) user are highly dependent on proper hygiene. The aim of this study was to compare the effect of solutions of Ricinus communis, in different concentrations, with solutions of alkaline peroxide and cetylpyridinium chloride 0.500 mg, in relation to the Cobalt Chromium (Co-Cr) alloy that composes the structure of RPD. The sample of the experiment consisted of 55 specimens of Co-Cr, made from circular wax patterns (12 mm x 3 mm) obtained in a metal matrix. The patterns were cast, randomly enumerated and divided into 5 immersion groups: H2Odeionized water (control) (15 minutes); Rc 2%- Ricinus communis 2% (20 minutes), Rc 10% -Ricinus communis 10% (20 minutes), PA-alkaline peroxide (15 minutes) and CCPcetylpyridinium chloride 0.500 mg (10 minutes). The specimens were evaluated for surface roughness (n = 10) at the beginning and after the simulation of 6 months, 1, 2, 3, 4 and 5 years by the laser confocal microscope (Sa, &micro;m) and by the rugosimeter of surface (Ra, &micro;m). One specimen from each group was analyzed for surface topography (Scanning Electron Microscopy, SEM) and Energy-dispersive X-ray spectroscopy (EDS) befofe and after simulation of use for 5 years. According to the results obtained (&alpha;= 0.05) by confocal microscopy (Sa), there was no difference for the solution factor (Kruskal- Wallis); For the time factor (Friedman) there was a statistical difference in Rc 2% in T0 to T1, T3, T4 and T6 (p <0.001) and Rc 10% in T2 to T3 (p = 0.007), with decrease in roughness. With the the rugosimeter (Ra), there was a statistical difference (Kruskal- Wallis) for CCP that presented less roughness in relation to the Rc 10% in T1 (p = 0.048) and T6 (p = 0.013). In relation to the time, (Friedman) the water caused a reduction of surface roughness (Ra) between T0 and T2 (p = 0.013). In the analysis of SEM and EDS it can be verified that the solutions did not present deleterious effects on the surfaces. It was concluded that although a statistical difference was found for roughness, the results are clinically acceptable. Thus, all solutions can be safely used for a period of 5 years.
20

EFEITO DA IMERSÃO PERIÓDICA EM SOLUÇÕES LIMPADORAS NA RUGOSIDADE SUPERFICIAL, PORCENTAGEM DE VARIAÇÃO DE MASSA E RESISTÊNCIA FLEXURAL DE LIGAS DE COBALTO-CROMO / Co-Cr ALLOY IMMERSION IN CLEANING SOLUTIONS: EFFECTS ON FLEXURAL STRENGTH, SURFACE ROUGHNESS AND PERCENTUAL OF VARIATION OF MASS

Borsa, Pedro Carlos Cortiana 22 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the flexural strength, elastic modulus, mass changes and surface roughness of two cobalt-chromium alloys, before and after immersions in four cleaning solutions and distilled water (as control). Co-Cr alloys (Co-Cr®, Dentsply-DeguDent Industria e Comércio, São Paulo, Brasil; and GM 800+®, Dentaurum GmbH & Co KG, Ispringen, Alemanha) were investigated. Fifty bar specimens (25 x 3 x 0,5 mm) for the flexural test, 50 quadrangular specimens (10 x 10 x 1 mm) for mass changes evaluation and 35 cylindrical specimens (10 x 1 mm) for surface roughness measurements were obtained by casting. They were polished by abrasive paper (#240 to #2500) and diamond polishing paste (3μm). Specimens were randomly divided into 5 groups according the following cleaning, solutions: pure white vinegar, 0.2% peracetic acid, sodium perborate - Corega Tabs®, 0.37% sodium hypochlorite and the control, distilled water. Surface roughness (Ra parameter) was analyzed using a profilometer (Mitutoyo SJ 410, Mitutoyo Corp, Kanagawa, Japan) before and after 5, 20 e 90 immersions (10 min each). Ra changes (ΔRa5, ΔRa20 e ΔRa90) were calculated for the different intervals. Qualitative surface analyses were performed by Scanning Electron Microscope (JSM 6360 SEM, JEOL). Both alloys, immersed in pure white vinegar, 0.2% peracetic acid, sodium perborate - Corega Tabs®, 0.37% sodium hypochlorite had similar roughness changes after 90 immersions (ΔRa from -0,012 to 0,022 μm). There was a significant surface roughening in hypochlorite (ΔRa90= 0,064 μm for CoCr®; and ΔRa90 = 0,592 μm for GM 800+). The number of immersions influenced on the roughness changes only in hypochlorite and there were greater changes in the GM 800+ alloy. After 90 immersions, GM 800+ alloy showed mass lost in the hypochlorite solution (-0,3%). This alloy presented higher flexural strength after 90 immersions in SH (σF= 1516 MPa in hypochlorite; 1366 MPa in control). However, there were no elastic modulus changes. CoCr® alloy did not present differences in the σF or in elastic modulus in any solution. The only solution that damaged the alloy surface was 0.37% sodium hypochlorite. / O objetivo deste trabalho foi avaliar a rugosidade superficial,o percentual de variação de massa, a resistência flexural e o módulo de elasticidade de duas ligas de Cobalto-Cromo após submetidas à imersões em quatro soluções limpadoras e água (controle). Foram utilizadas as ligas Co-Cr® DeguDent (Dentsply-DeguDent Industria e Comércio, São Paulo, Brasil) e Remanium® GM 800+ (Dentaurum GmbH & Co KG, Ispringen, Alemanha). De cada liga fundiu-se cinquenta corpos de prova, 50 cilíndricos (10 x 1 mm) para a análise da rugosidade, 50 quadrangulares (10 x 10 x 1 mm) para avaliação da variação de massa e em formato retangular (25 x 2,5 x 0,75 mm) para o teste flexão 3 pontos. O polimento se deu por seqüencia de lixas (#400 a 2500) e pasta diamantada (3μm). A distribuição aleatória foi em 5 grupos, conforme os agentes de limpeza: vinagre branco puro, ácido peracético 0,2% , perborato de sódio (Corega Tabs®), hipoclorito de sódio 0,37% e o controle: água destilada. Foram realizadas avaliações da rugosidade superficial (Parâmetro Ra) através de rugosímetro (Mitutoyo SJ 410, Mitutoyo Corp, Kanagawa, Japan) antes e após 5, 20 e 90 ciclos de imersão de 10 minutos. As alterações de Ra (ΔRa5, ΔRa20 e ΔRa90) foram calculadas entre os diferentes interrupções. Análise complementar da superfície foi realizada em imagens obtidas por microscopia eletrônica de varredura (JSM 6360 SEM, JEOL Ltd., Tokyo, Japan). A pesagens dos corpos de prova para cálculo da variação de massa se deu após 5 e 90 imersões, utilizando-se de balança eletrônica analítica com sensibilidade de 0,0001 g (FA 2004, Coleman E. P. L. Com. e Imp. Ltda. Santo André, São Paulo). Os ensaios de flexão a 3 pontos para determinação da resistência flexural (σF) e do módulo de elasticidade foram realizados após 90 imersões. Os dados obtitos foram analisados quanto a normalidade e testes de comparação entre médias foram aplicados conforme o tipo de distribuição. As duas ligas, imersas nas soluções vinagre puro, ácido peracético, corega tabs® apresentaram comportamento semelhante em relação as alterações de rugosidade superficial (Ra), quando comparadas ao controle, após 90 imersões (ΔRa entre -0,012 e 0,022 μm). Aumento da rugosidade significativo ocorreu na solução de hipoclorito (ΔRa90= 0,064 μm (CoCr®) e 0,592 μm (GM 800+). O número de imersões influenciou na variação de rugosidade, apenas para a solução de hipoclorito, sendo que as maiores variações ocorreram na liga GM 800+. Após 90 imersões a liga GM 800+ demonstrou perda de massa na solução de hipoclorito (-0,3%). Ocorrendo para essa liga aumento da resistência flexural (σF= 1516 MPa em hipoclorito; 1366 MPa no controle) após 90 imersões, sem modificação de seu módulo de elasticidade. A liga CoCr® não apresentou diferenças na σF ou no módulo de elasticidade nas diferentes soluções. A única solução que causou dano à superfície das ligas foi o hipoclorito de sódio 0,37%.

Page generated in 0.0551 seconds