Spelling suggestions: "subject:"cobertura - engenharia"" "subject:"obertura - engenharia""
1 |
Cobertura vegetal na região central das capitais brasileirasRocha, Mariane Félix da January 2017 (has links)
Orientador : Prof. Dr. João Carlos Nucci / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Terra, Programa de Pós-Graduação em Geologia. Defesa: Curitiba, 28/04/2017 / Inclui referências : f. 76-85 / Resumo: Várias capitais estaduais brasileiras possuem um título de cunho ambiental: "capital mais verde", "capital mais sustentável" ou "capital mais arborizada" do Brasil ou do mundo. Poucos desses títulos, no entanto, foram precedidos de estudos que explicassem a conceituação e metodologia empregadas para se chegar a tal resultado. Tendo em vista essa lacuna, este trabalho teve como objetivo estabelecer um ranking entre capitais estaduais e distrital brasileiras com base na cobertura vegetal. Foram utilizadas, na construção desse ranking, imagens de satélite do software Google Earth e os polígonos de cobertura vegetal de todas as 27 capitais foram editados no software ArcGIS 10.2.2. Devido ao tempo determinado para a pesquisa, optou-se por mapear apenas as áreas centrais das capitais, em um raio de 500m em torno de alguns pontos de referência comumente encontrados no centro das cidades, como Igreja Matriz, sede da Prefeitura e Marco Zero. Finalizada a etapa do mapeamento e estabelecido o ranking, Brasília (DF) alcançou a primeira posição, com 31,83% de cobertura vegetal na área mapeada, e Aracaju (SE) ficou em último lugar, com 6,38% de cobertura vegetal em sua área central. Entretanto, constatou-se que não se tratou de um ranking justo, em função da dificuldade de localizar com precisão o centro das capitais, além de ter havido muita divergência nas imagens de satélite disponíveis para cada capital, com datas muito diferentes e resoluções e qualidade das imagens incompatíveis com a comparação que se pretendia fazer. Ademais, as capitais estaduais e distrital apresentam condições físicas, históricas e socioeconômicas muito diversas entre si, o que igualmente torna injusta a comparação entre elas. Palavras-chave: Ranking. Capitais. Cobertura vegetal. Área Central. Planejamento da Paisagem. / Abstract: Several brazilian state capitals have an environmental title: "greener capital", "most sustainable capital" or "most wooded capital" of Brazil or the world. Few of these titles, however, were preceded by studies that explained the conceptualization and methodology used to reach such a result. In view of this gap, this study aimed to establish a ranking between brazilian state and district capitals based on vegetation cover. In the construction of this ranking, satellite images of the Google Earth software were used and the vegetation cover polygons of all 27 capitals were edited in ArcGIS 10.2.2 software. Due to the time determined for the research, it was decided to map only the central areas of the capitals, within a radius of 500m around some landmarks commonly found in the center of cities, such as Mother Church, City Hall and the zero milestone marker. Completed the mapping stage and established the ranking, Brasília (DF) reached the first position, with 31,83% of vegetation cover in the mapped area, and Aracaju (SE) was the last, with 6,38% of vegetation cover in its central area. However, it was verified that it was not a fair ranking due to the difficulty of locating the capital center with precision, besides there was a lot of divergence in the satellite images available for each capital, with very different dates, resolutions and image quality incompatible with the comparison that was intended to be made. In addition, state and district capitals present very different physical, historical and socioeconomic conditions among themselves, which also makes it unfair to compare them. Key-words: Ranking. Capitals. Vegetation cover. City center. Landscape Planning.
|
2 |
Estudo de cobertura para grandes vãos utilizando perfis tubulares.Furtini, Flávia Macedo January 2005 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2014-12-17T20:13:37Z
No. of bitstreams: 1
DISSERTAÇÃO_EstudoCoberturaGrandes.pdf: 25162454 bytes, checksum: d9338c390c64efc3110e52c632309675 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-01-16T15:31:55Z (GMT) No. of bitstreams: 1
DISSERTAÇÃO_EstudoCoberturaGrandes.pdf: 25162454 bytes, checksum: d9338c390c64efc3110e52c632309675 (MD5) / Made available in DSpace on 2015-01-16T15:31:55Z (GMT). No. of bitstreams: 1
DISSERTAÇÃO_EstudoCoberturaGrandes.pdf: 25162454 bytes, checksum: d9338c390c64efc3110e52c632309675 (MD5)
Previous issue date: 2005
|
3 |
Readequação de coberturas através da técnica de telhados verdes : estudo de caso nas escolas públicas do Estado do ParanáUhmann, Isaura Marques de Souza January 2016 (has links)
Orientador : Prof. Dr. Sérgio Fernando Tavares / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Construção Civil. Defesa: Curitiba, 22/04/2015 / Inclui referências : f. 126-131 / Area de concentração : Ambiente construído e gestão / Resumo: Em um contexto aonde a arquitetura vem discutindo seu papel na busca por um mundo mais sustentável destaca-se a presença dos aspectos relativos à sustentabilidade no edifício escolar. Essa tipologia arquitetônica deve se constituir em uma referência de arquitetura, funcionando como agente disseminador dos conceitos essenciais à obtenção de uma arquitetura de qualidade, para a qual os parâmetros da sustentabilidade são fundamentais. Esta pesquisa compara a substituição dos telhados originais utilizados nos projetos padrões do estado do Paraná, por telhados verdes extensivos cujos materiais componentes têm menor energia embutida EE e índices reduzidos de CO2. O custo ambiental da demolição e o gasto energético de novos materiais já são razões substanciais para considerar a readequação das edificações. Justifica-se ainda, a aplicação em instituições públicas onde se busca racionalizar os recursos disponíveis para obras de reparos, manutenção e melhorias. A pesquisa tem natureza exploratória com aplicação em estudo de caso. As comparações realizadas nesta pesquisa apontam para a viabilidade na implementação da readequação por telhados verdes extensivos, uma vez que refletiram resultados favoráveis com redução significativa da energia embutida e emissão de CO2. O estudo desenvolvido propõe ideias e diretrizes para os projetos de readequação, sejam eles específicos ou padronizados, fomentando a eco educação da comunidade escolar, possibilitando vivenciar essa prática no próprio espaço de convívio diário de alunos, pais e professores, gerando um modelo a ser multiplicado, incentivando as práticas de conservação, respeito ao bem edificado e integração à natureza. Palavras chave: arquitetura escolar, telhados verdes, energia embutida, emissão de CO2. / Abstract: In a context where the architecture has been discussing its role in the search for a more sustainable world, there is the presence of sustainability aspects in the school building. This architectural typology should constitute a reference architecture, functioning as disseminating agent of the key concepts to obtain a quality architecture, for which the parameters of sustainability are key. This research simulates the replacement of original roofs used in standards of Paraná state for extensive green roof projects whose material components have lower embodied energy EE and reduced levels of CO2. The environmental cost of demolition and energy expenditure of new materials are already substantial reasons to believe that retrofitting of buildings. It is also justified the application in public institutions which seek to rationalize the resources available for repair works, maintenance and improvements. The research has an exploratory nature with application in a case study. The simulations in this research point to the feasibility for implementation of readjustment for extensive green roofs, as reflected favorable results with significant reduction in embodied energy and CO2 emissions. The study developed provides greater quality to the built environment and proposes ideas and guidelines for new projects, whether specific or standardized, fostering the ecological education at school community, enabling experience this practice in the daily living space of students, parents and teachers, generating a model to be multiplied by encouraging conservation practices, respect for the construction and integration with nature. Keywords: school architecture , green roofs , embodied energy , CO2 emissions.
|
4 |
Análise do fluxo de informações no processo de manutenção predial apoiada em BIM : estudo de caso em coberturasMaia, Bárbara Lepca January 2016 (has links)
Orientador : Prof. Dr. Sérgio Scheer / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Construção Civil. Defesa: Curitiba, 28/03/2016 / Inclui referências : f. 89-95 / Area de concentração : Ambiente construído e gestão / Resumo: As patologias na construção civil podem causar muitos transtornos aos seus ocupantes e em casos extremos, podem vir a causar a ruína da edificação. A problemática a ser resolvida com esta pesquisa é como a manutenção em edificações pode ser facilitada através da gestão da informação apoiado pelo processo BIM (Building Information Modeling). O objetivo geral foi realizar a análise do fluxo de informações no processo de manutenção predial apoiada pelo conceito BIM, o qual propõe um formato definido para facilitar a exploração de todas as informações do ciclo de vida do projeto. Para atingir tal objetivo foi realizada a análise do fluxo, uso e formato das informações no processo de correção de não-conformidades (patologias) em sistemas de coberturas de fibrocimento especificamente. Essas análises são baseadas em referencial teórico e também em um estudo de caso, cuja unidade de análise é composta por catorze edifícios residenciais concluídos entre 2006 e 2015, todos executados pela mesma construtora em Curitiba/PR. O produto final apresentado neste trabalho é um conjunto de quatro propostas de fluxos informacionais que visam a solução de dois terços das solicitações de manutenção estudadas. Palavras chave: manutenção predial, gestão da informação, BIM, modelagem da informação da construção. / Abstract: Pathologies in construction can cause a lot of inconvenience to the occupants and in extreme cases may come to cause the ruin of the building. The problem to be solved with this research is how the maintenance in buildings can be facilitated by information management supported by BIM (Building Information Modeling). The general objective is to analyze the flow of information on building maintenance process supported by the BIM concept, which proposes a set format for easy use of all the information of the project life cycle. To achieve this goal was accomplished the analysis of the flow, use and format of the information on noncompliances correction process (conditions) in fiber cement roofing systems specifically. These analysis are based on theory framework and also in a case study, whose analysis units are fourteen residential buildings completed between 2006 and 2015, all built by the same organization in Curitiba / PR. The final product presented in this work is a set of four information flows proposals aimed at solving two-thirds of the studied maintenance requests.Keywords: building maintenance, information management, BIM, building information modeling.
|
5 |
Estudo das temperaturas superficiais de coberturas verdes e convencionais na perspectiva de mitigação das ilhas de calor urbano no Centro de Curitiba - ParanáScroccaro, Mateus Pedro January 2016 (has links)
Orientador : Profª. Drª. Cristina de Araújo Lima / Coorientador : Prof. Dr. Sérgio Fernando Tavares / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Construção Civil. Defesa: Curitiba, 19/04/2016 / Inclui referências : f. 113-125 / Area de concentração : Ambiente Construído / Resumo: A partir do final da década de 1960 a sociedade em seus mais variados segmentos intensificou a discussão acerca do desenvolvimento sustentável, além de incorporar novas temáticas, técnicas e comportamentos mais sustentáveis, primando por uma forma de pensar e agir que proporcione melhor qualidade de vida para as gerações presentes e as futuras. Nesse contexto, a técnica de cobertura verde (CV) é considerada uma forma de atenuar os impactos do ser humano no meio ambiente, contribuindo para amenizar efeitos notadamente negativos, como por exemplo o fenômeno de ilha de calor urbano (ICU). Sendo a alteração de temperatura uma das principais características do fenômeno ICU, a presente dissertação tem como objetivo principal investigar a possível colaboração da temperatura superficial das CVs na mitigação dos efeitos das ICUs. Para o cumprimento desse objetivo, foram estabelecidas duas principais etapas: na primeira houve a revisão do estado da arte dos temas contemplados na dissertação, abrangendo principalmente artigos científicos nacionais e internacionais e os autores já considerados como referência no tema. Num segundo momento foram utilizados dois métodos de desenvolvimento da pesquisa: um experimento físico constituído de uma CV extensiva e telhados de comparação, formados de telhas cerâmicas vermelhas e telhas de fibrocimento. A outra parte do método foi um exercício de representação gráfica, analisando um recorte urbano em Curitiba - Paraná - Brasil, no qual foram projetados os dados de temperatura superficial obtidos no experimento físico. Para o experimento físico com a CV e os telhados de comparação, os resultados permitiram inferir que quanto mais altas foram as temperaturas superficiais, maiores foram as perdas de calor para o ambiente, sendo que as coberturas cerâmica e de fibrocimento foram as que mais aqueceram durante o dia e as que mais rapidamente resfriaram à noite. A cobertura cerâmica apresentou as maiores temperaturas superficiais, seguidas pela cobertura de fibrocimento e pela CV. Contudo, através de análises estatísticas verificou-se que entre as médias das temperaturas superficiais da cerâmica e do fibrocimento não houve diferenças significativas, contrariamente à CV, que teve a menor variação na temperatura superficial, mantendo mais estáveis essas temperaturas tanto de dia quanto à noite e que, estatisticamente, apresentou diferenças significativas com relação à cerâmica e a fibrocimento. O exercício de representação gráfica dos dados do experimento físico teve como resultado a visualização através de imagens do possível desempenho da temperatura superficial dos três tipos de cobertura no recorte urbano escolhido. Como conclusões, verificou-se que o envelhecimento e a sujidade da telha cerâmica poderiam ser fatores que influenciaram o seu desempenho térmico, sobreaquecendo sua superfície mais do que a superfície do fibrocimento. O experimento físico se mostrou eficiente e recomendável quanto à obtenção de dados para o que foi proposto, ou seja, para obtenção da temperatura superficial, estando os resultados compatíveis com a bibliografia estudada e apontando positivamente para um possível benefício da CV na mitigação dos efeitos das ICUs. O exercício de representação gráfica, por sua vez, permitiu elencar as variáveis que mais poderiam influenciar nos resultados e apresentou algumas características inerentes a esse experimento, como as dificuldades em sistematizar os procedimentos metodológicos e em limitar a área de estudo. Palavras-chave: Ilha de calor urbano. Temperatura superficial. Cobertura verde. Telha cerâmica. Telha de fibrocimento. Curitiba. / Abstract: From the late 1960s the society in its various segments intensified the discussion about sustainable development, as well as incorporating new themes, techniques and more sustainable behavior, striving for a way of thinking and acting to provide better quality of life for generations in the present and in the future. In this context, the green roof (GR) technique is considered a way to mitigate the impacts of man on the environment, contributing to soften markedly negative effects, such as the urban heat island (UHI) phenomenon. Since the change in temperature is one of the main features of the UHI phenomenon, this dissertation aims to investigate the possible collaboration of the surface temperature of GRs in mitigating the effects of UHIs. For achieving this goal, two main stages were established: the first was to review the state of the art of the topics covered in the dissertation, mainly covering national and international scientific articles and authors have considered as a reference in the subject. Secondly it was used two research development methods: a physical experiment made of an extensive GR and comparison of roofs formed of red ceramic tiles and fiber cement tiles. The other part of the method was an exercise of graphical representation in an urban cut in Curitiba - Paraná - Brazil, in which the surface temperature data obtained in physical experiment were designed. For the physical experiment with GR and comparison roofs, the result showed that the higher were the surface temperatures, higher were the heat loss to the environment, and the ceramic and fiber cement roofs were the most heated during the day and the fastest cooled at night. The ceramic cover showed the highest surface temperatures, followed by the fiber cement roof and the GR. However, through statistical analysis it was found that between the mean surface temperatures of the ceramic and fiber cement no significant differences, unlike the GR, which had the lowest variation in surface temperature, maintaining more stable these temperatures both day and night and that, statistically, there was significant differences with respect to the ceramic and fiber cement. The exercise of graphical representation of the physical experiment data resulted throgh images in the display of the possible behavior of the surface temperature of the three types of coverage in urban crop chosen. As conclusions, it was found that aging and dirt from ceramic tile could be factors that influenced its thermal performance, overheating the surface more than the surface of the fiber cement. The physical experiment proved effective and recommended in obtaining data to what was proposed, that is for measuring surface temperature, and the results are consistent with the literature studied and pointing positively to a possible benefit of the GR in mitigating the effects of UHIs. The exercise of graphical representation, on the other hand, allowed to list the variables that most could influence the results and presented some characteristics inherent in this experiment, like the difficulties to systematize the methodological procedures and limiting the study area. Keywords: Urban heat island. Surface temperature. Gren roof. Ceramic tile. Fiber cement tile. Curitiba.
|
6 |
Comportamento térmico de coberturas de fibrocimento em Campinas, SP: aplicação de técnicas passivas / Thermal behavior of fiber-cement roofing in Campinas, SP: application of passive coolingTeixeira, Carla Fernanda Barbosa 07 1900 (has links)
O Brasil possui a maior parte de suas terras em clima tropical. Sendo a cobertura o elemento construtivo mais exposto à radiação solar direta, toma-se um desafio aos pesquisadores e projetistas, atenuar as temperaturas nas coberturas das edificações e contribuir para o uso racional de energia. O objetivo desta pesquisa é monitorar o desempenho térmico de coberturas de fibrocimento em_ células-teste na cidade de Campinas, SP, com aplicação de técnicas passivas de resmamento. Utilizaram-se quatro células-teste: uma célula-teste de referência, e outras três com os sistemas: evaporativo, radiante e reflexivo, respectivamente, e monitoramento das temperaturas superficiais internas das telhas (TT' s) e temperaturas do ar dos áticos (T AA' s), no período de 21 de janeiro a 9 de fevereiro de 2006. Para o sistema de resmamento evaporativo foram utilizados ciclos de aspersão com diferentes intervalos no período todo. Entre as técnicas monitoradas, o melhor comportamento térmico foi verificado no 2° período (de 26 a 30/jan com aspersão contínua) na temperatura da superficie interna da telha do sistema evaporativo (TTevap = 23,2°C) apresentando um decréscimo de 1,3°C em relação a célulateste de referência e um acréscimo de 0,1 °C em relação as médias da temperatura do ar para o período. Nas médias da temperatura do ar dos áticos, o 2° período apresentou os menores valores para os sistemas: reflexivo (TAArefl =23,4°C) e evaporativo (TAAevap = 23,5°C), apresentando uma atenuação de 0,5°C e 0,4°C em relação a célula de referência respectivamente, além de uma elevação de 0,3°C em relação as médias da temperatura do ar externo. Os resultados, analisados através de tratamento estatístico, demonstram a viabilidade do uso do sistema evaporativo em condições climáticas de elevada umidade relativa do ar, contribuindo para atenuar os efeitos das hostilidades climáticas em coberturas das edificações._________________________________________________________________________________________ ABSTRACT: In Brazil, the tropical climate is predominant in most of regions. Roofing is the building component with the highest exposition to direct solar radiation. The challenge for researchers and designers is to achieve cornfort in the built environrnent and to contribute to energy saving, proposing roofing systems with good thermal insulation, and consequently lesser internal surface temperatures. The objective of this research is to monitor the thermal behavior of fiber-cement roofing and to present a discussion about the results obtained in cell-tests in the city of Campinas, SP, through passive cooling techniques. Four cell-tests were used: one cell-test was adopted as reference, and the other three were analyzed with evaporative, radiative and reflective systems, respectively. The evaporative system was tested with different aspersion cycles through spraying systems and intervals. The monitored parameters were the internal surface temperatures of the roofing tiles (TT s) and attic air temperatures (TAA's) in the period of January 21st to February 9th of2006. Among the monitored passive techniques, the best thermal behavior was observed in the 2nd period (iTom January 26th to 30th, corresponding to continue spraying), related to the internal surface temperature with the evaporative system (TTevap = 23,2°C). A reduction of 1,3°C was observed, as compared to the reference test-cell and and an increase of 0,1 °C in comparison with the average air temperature. In relation to the average of attic air temperature, the 2nd period presented the lowest temperature for reflexive system (T AArefl = 23,4°C) and evaporative system (TAAevap = 23,5°C); a reduction of 0,5°C and 0,4°C in relation of the reference test-cell respectively was observed; also, it showed an increase of 0,3°C as compared with air temperature. The results presented through statistical analyses demonstrated that the use of the evaporative system in climatic conditions with high relative humidity is viable, contributing, therefore, to attenuate the effects of climatic hostilities in the roofing buildings.
|
7 |
Comportamento térmico de coberturas de fibrocimento em Campinas, SP: aplicação de técnicas passivas / Thermal behavior of fiber-cement roofing in Campinas, SP: application of passive coolingTeixeira, Carla Fernanda Barbosa 07 1900 (has links)
O Brasil possui a maior parte de suas terras em clima tropical. Sendo a cobertura o elemento construtivo mais exposto à radiação solar direta, toma-se um desafio aos pesquisadores e projetistas, atenuar as temperaturas nas coberturas das edificações e contribuir para o uso racional de energia. O objetivo desta pesquisa é monitorar o desempenho térmico de coberturas de fibrocimento em_ células-teste na cidade de Campinas, SP, com aplicação de técnicas passivas de resmamento. Utilizaram-se quatro células-teste: uma célula-teste de referência, e outras três com os sistemas: evaporativo, radiante e reflexivo, respectivamente, e monitoramento das temperaturas superficiais internas das telhas (TT' s) e temperaturas do ar dos áticos (T AA' s), no período de 21 de janeiro a 9 de fevereiro de 2006. Para o sistema de resmamento evaporativo foram utilizados ciclos de aspersão com diferentes intervalos no período todo. Entre as técnicas monitoradas, o melhor comportamento térmico foi verificado no 2° período (de 26 a 30/jan com aspersão contínua) na temperatura da superficie interna da telha do sistema evaporativo (TTevap = 23,2°C) apresentando um decréscimo de 1,3°C em relação a célulateste de referência e um acréscimo de 0,1 °C em relação as médias da temperatura do ar para o período. Nas médias da temperatura do ar dos áticos, o 2° período apresentou os menores valores para os sistemas: reflexivo (TAArefl =23,4°C) e evaporativo (TAAevap = 23,5°C), apresentando uma atenuação de 0,5°C e 0,4°C em relação a célula de referência respectivamente, além de uma elevação de 0,3°C em relação as médias da temperatura do ar externo. Os resultados, analisados através de tratamento estatístico, demonstram a viabilidade do uso do sistema evaporativo em condições climáticas de elevada umidade relativa do ar, contribuindo para atenuar os efeitos das hostilidades climáticas em coberturas das edificações._________________________________________________________________________________________ ABSTRACT: In Brazil, the tropical climate is predominant in most of regions. Roofing is the building component with the highest exposition to direct solar radiation. The challenge for researchers and designers is to achieve cornfort in the built environrnent and to contribute to energy saving, proposing roofing systems with good thermal insulation, and consequently lesser internal surface temperatures. The objective of this research is to monitor the thermal behavior of fiber-cement roofing and to present a discussion about the results obtained in cell-tests in the city of Campinas, SP, through passive cooling techniques. Four cell-tests were used: one cell-test was adopted as reference, and the other three were analyzed with evaporative, radiative and reflective systems, respectively. The evaporative system was tested with different aspersion cycles through spraying systems and intervals. The monitored parameters were the internal surface temperatures of the roofing tiles (TT s) and attic air temperatures (TAA's) in the period of January 21st to February 9th of2006. Among the monitored passive techniques, the best thermal behavior was observed in the 2nd period (iTom January 26th to 30th, corresponding to continue spraying), related to the internal surface temperature with the evaporative system (TTevap = 23,2°C). A reduction of 1,3°C was observed, as compared to the reference test-cell and and an increase of 0,1 °C in comparison with the average air temperature. In relation to the average of attic air temperature, the 2nd period presented the lowest temperature for reflexive system (T AArefl = 23,4°C) and evaporative system (TAAevap = 23,5°C); a reduction of 0,5°C and 0,4°C in relation of the reference test-cell respectively was observed; also, it showed an increase of 0,3°C as compared with air temperature. The results presented through statistical analyses demonstrated that the use of the evaporative system in climatic conditions with high relative humidity is viable, contributing, therefore, to attenuate the effects of climatic hostilities in the roofing buildings.
|
8 |
Contribuição ao projeto de coberturas tridimensionaisArcaro, Vinicius Fernando, 1958- 21 July 2018 (has links)
Orientador: Fernando Iguti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-21T07:15:39Z (GMT). No. of bitstreams: 1
Arcaro_ViniciusFernando_D.pdf: 21746782 bytes, checksum: 85e16f75faf1ede316edf57c4fb26e90 (MD5)
Previous issue date: 1996 / Resumo: Este trabalho considera dois tipos de coberturas tridimensionais: treliça espacial e rede de cabos, focalizando na formulação exata do tratamento teórico de hastes quando sujeitas a grandes mudanças na geometria. No caso de treliça espacial, apresenta urna heurística para o dimensionamento de mínimo peso de treliças espaciais constituídas por tubos cilíndricos de aço. A estratégia de mínimo peso significa um esforço para minimizar o custo deste tipo de treliça que é bastante comum na prática da engenharia civil. Nos subproblemas de cálculo de equilíbrio, o surpreendente desempenho do método quase Newton sem memória é revelado quando comparado com os métodos quase Newton e Newton. Uma aplicação da heurística a um caso real envolvendo milhares de deslocamentos e milhares de barras é apresentado. No caso de rede de cabos, proporciona um guia realista seguro sobre o comportamento de sistema estruturais com rede de cabos. A formulação matemática é especialmente adequada para modelar a etapa de tensionamento que é geralmente necessária nas tenso estruturas. Os resultados de um modelo experimental de rede de cabos tensionados, na forma de um parabolóide hiperbólico, ancorada em vigas rígidas retas, são comparados com os resultados do modelo teórico. Um caso real é analisado, onde a estrutura é urna rede de cabos de aço, na forma de um parabolóide hiperbólico, ancorada num anel de concreto, cujo eixo projeta uma elipse no plano horizontal / Abstract: This work considers two types of tridimensional roofs: space truss and cable network, focusing on exact formulation in the theoretical treatment of stems when subjected to large changes in geometry. In case of space truss, it presents a heuristic to minimum weight design of space trusses composed of steel cylindrical tubes. The minimum weight strategy means an effort to minimize the cost of this type of truss, which is very common in the civil engineering practice. In sub-problems of equilibrium calculation, the surprising performance of the memoryless quasi Newton method is revealed when compared to the quasi Newton and Newton methods. An application of the heuristic to a real case encompassing thousands of displacements and thousand of members is presented. In case of cable network, it provides a sound practical guidance on the behavior of cable structural systems. The mathematical formulation is specially suited to model the tensioning stage, which is generally necessary in tension structures. The results from an experimental model of a tensioned cable network, in the shape of hyperbolic paraboloid, anchored at straight rigid beams, are compared with the results from the theoretical model. A real case is analyzed, where the structure is a steel cables network, in the shape of hyperbolic paraboloid, anchored at a concrete ring bearn, whose axis projects an ellipse in the horizontal plane / Doutorado / Mecanica Computacional / Doutor em Engenharia Mecânica
|
9 |
Desempenho de diferentes revestimentos em brochas de aço rapido / Performance of differents coatings on high speed steel broachsAndrade, Sergio Henrique 13 August 2018 (has links)
Orientador: Anselmo Eduardo Diniz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-13T04:02:58Z (GMT). No. of bitstreams: 1
Andrade_SergioHenrique_M.pdf: 4174934 bytes, checksum: 56bb8050f3369366b8e5e63b5735cf0b (MD5)
Previous issue date: 2009 / Resumo: O aco rapido e um material que apresenta elevada resistencia ao desgaste e elevada dureza
a quente, tendo grande aplicacao na construcao de ferramentas de dimensoes e formas complexas,
tais como brochas. O presente trabalho avaliou a utilizacao de coberturas de materiais mais
resistentes ao desgaste em brochas de aco rapido no brochamento interno de perfil, utilizando
como corpo de prova o componente do conjunto de disco de embreagem denominado cubo de
embreagem, fabricado em aco DIN C45. Foram realizados ensaios variando-se tres tipos de
revestimentos, TiN, TiCN e AlCrN, e dois tipos de substratos, o aco rapido convencional M2 e o
aco rapido sinterizado. Foram medidos o desgaste e a vida da ferramenta, a pressao no sistema
hidraulico da brochadeira e a dimensao do perfil interno do corpo de prova. A analise dos
resultados permitiu concluir que as brochas com cobertura apresentaram uma maior vida, quando
comparado com as brochas sem cobertura, mesmo quando a brocha e reafiada e nao recoberta,
trabalhando sem cobertura na superficie de saida. Entre as coberturas, o TiCN e AlCrN foram que
apresentaram melhor rendimento, apesar da pequena vantagem da cobertura de TiCN, nao foi
possivel afirmar estatisticamente que existe diferenca entre as duas coberturas. A utilizacao da
cobertura, ao contrario do esperado, causou aumento na pressao do sistema hidraulico da
brochadeira para os tres tipos de cobertura. Nao ocorreu grandes diferencas, em relacao a vida da
ferramenta, quando comparou-se as brochas com substratos de aco rapido convencional e o
sinterizado. Ficou constatado que a dimensao do perfil nao sofre grande variacao durante uma
vida da ferramenta. / Abstract: The high speed steels is a material with high wear resistance and high hot hardness, with
large application to made tools with complex shape and dimension. The present work evaluated
the application of wear resistance materials on high speed steel broach in broaching of profile,
using like specimen a clutch component denominated hub, made DIN C45 steel. It has been made
three different tests varying the coatings, TiN, TiCN and AlCrN, two different substrates, the
conventional high speed steel M2 and the powder metallurgy high speed steel. Tool wear, tool
life, pressure in the broaching machine hydraulic system and the profile dimension were
measured. The analysis of the results allowed us to conclude that the broaches with coating led to
a longer tool life than the condition without coating, the same happened when the broach was
resharpened and didn't receive a new coating, working without coating in the rake face. Between
the coatings, the TiCN and AlCrN have shown the best performances, although TiCN has a little
advantage, it wasn't possible to say statistically that there is a difference between them. The use
of coating, in the opposite was waiting, has cause the increase of the pressure in the broaching
machining hydraulic system for the three kinds of coatings. Didn't occur much difference at the
tool's life when comparing the conventional high speed steel and the powder metallurgy high
speed steel substrates. We've come to the conclusion that the profile dimension doesn't suffer
much variation during one tool's life. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
|
10 |
Transmissão de calor em regime periodico : efeito da inercia termica em fechamentos opacosGranja, Ariovaldo Denis, 1963- 31 July 2018 (has links)
Orientador : Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-31T23:08:17Z (GMT). No. of bitstreams: 1
Granja_AriovaldoDenis_D.pdf: 766890 bytes, checksum: cfaee3ae0e3e66bb8d376d2619bda5ad (MD5)
Previous issue date: 2002 / Doutorado
|
Page generated in 0.105 seconds