• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 41
  • 22
  • 8
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 234
  • 234
  • 89
  • 71
  • 45
  • 45
  • 44
  • 32
  • 29
  • 28
  • 25
  • 25
  • 24
  • 22
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Caracterização do potencial evocado auditivo cortical P1-N1-P2 em crianças com estimulação bimodal / Characterization of cortical auditory evoked potential P1-N1-P2 in children with bimodal stimulation

Rodrigues, Amanda Giorgetto 26 February 2016 (has links)
Introdução: O implante coclear (IC) amplamente aceito como forma de intervenção e (re) habilitação nas perdas auditivas severas e profundas nas diversas faixas etárias. Contudo observa-se no usuário do IC unilateral queixas como localização e compreensão sonora em meio ao ruído, gerado pelo padrão anormal de estimulação sensorial. A fim de fornecer os benefícios da audição binaural, é preconizado a estimulação bilateral, seja por meio do IC bilateral ou com a adaptação de um aparelho de amplificação sonora individual (AASI) contralateralmente ao IC. Esta última condição é referida como estimulação bimodal, quando temos, concomitantemente dois modos de estimulação: Elétrica (IC) e acústica (AASI). Não há dados suficientes na literatura voltados à população infantil que esclareça ou demonstre o desenvolvimento do córtex auditivo na audição bimodal. Ressalta-se que não foram encontrados estudos em crianças. Objetivo: Caracterizar o PEAC complexo P1, N1 P2 em usuários da estimulação bimodal e verificar se há correlação com testes de percepção de fala. Metodologia: Estudo descritivo de séries de casos, com a realização do PEAC em cinco crianças usuárias da estimulação bimodal, a partir da metodologia proposta por Ventura (2008) utilizando o sistema Smart EP USB Jr da Intelligent Hearing Systems. Foi utilizado o som de fala /da/, apresentado em campo livre. O exame será realizado em três situações: Somente IC, IC e AASI e somente AASI. A análise dos dados dos potenciais corticais foi realizada após a marcação da presença ou ausência dos componentes do complexo P1-N1-P2 por dois juízes com experiência em potenciais evocados. Resultados: Foi obtida a captação do PEAC em todas as crianças em todas as situações de teste, além do que foi possível observar a correlação destes com os testes de percepção auditiva da fala. Foi possível verificar que o registro dos PEAC é um procedimento viável para a avaliação da criança com estimulação bimodal, porém, ainda não há dados suficientes quanto a utilização deste para a avaliação e indicação do IC bilateral. / Introduction: The cochlear implant (CI) is already accepted in the area, as an intervention (re)habilitation in severe and profound hearing loss in different age groups. However, it is observed in the unilateral CI users have complaints such as sound localization and understanding speech in noise. Recent studies with Cortical Auditory Evoked Potential (CAEP) demonstrated the fact that the CI cannot favors the ipsilateral development of the auditory pathway as expected. Therefore, unilateral CI users have an abnormal pattern of sensory stimulation. In this sense, the patient is advised and encouraged as to the fitting of hearing aids (HA) in no-implanted ear, especially in the presence of residual acoustic hearing in order to provide the benefits of binaural hearing. This condition is referred to bimodal hearing, when combining electric stimulation from the CI with acoustic stimulation from the contralateral ear provides to HA. Not enough data in the literature has focused on the child population to clarify or demonstrate the development of the auditory cortex in the bimodal hearing. Objective: To characterize the CAEP complex P1-N1-P2 users of bimodal stimulation and check for correlation with performance on tests of speech perception. Methods: A cross-sectional observational study, with the completion of the CAEP in six children using the Bimodal stimulation, the CAEP recording will be based in the methodology proposed by VENTURA (2008) using the system Smart EP USB Jr Intelligent Hearing Systems. The speech sound / of /, presented in free field, will be used. The potential will be recorded in three situations: monaural hearing (only CI); Bimodal hearing (IC and HA) and monoaural hearing (only HA). The examination will be held in three situations: monaural hearing (only IC); Bimodal hearing (IC and hearing aids) and hearing monaural (only the hearing aid). Data analysis of the cortical potential was performed after the marking of the presence or absence of the components of the N1-P1-P2 complex by two judges experienced in evoked potentials. It was verified that the record of the ECCP is a viable procedure for the assessment of children with bimodal stimulation and can assist in bilateral IC nomination process or the maintenance of bimodal stimulation.
102

Componente P1 do potencial evocado auditivo cortical nos primeiros meses de uso do implante coclear na desordem do espectro da neuropatia auditiva / P1 cortical auditory evoked potential in the first months of cochlear implant use in auditory neuropathy spectrum disorder

Vicente, Leticia Cristina 25 April 2014 (has links)
O implante coclear tem sido considerado uma opção de reabilitação em pacientes com a Desordem do Espectro da Neuropatia Auditiva. Contudo, a sua indicação é relativamente recente, e, com isso, poucos estudos investigaram o desenvolvimento cortical nestes pacientes. Até o momento, não há estudos longitudinais que caracterizem o desenvolvimento do sistema auditivo central após a ativação do implante coclear. O objetivo deste trabalho foi caracterizar o componente P1 do potencial evocado auditivo cortical nos primeiros meses de uso do implante coclear em crianças com a Desordem do Espectro da Neuropatia Auditiva. Participaram deste estudo oito crianças diagnosticadas com Desordem do Espectro da Neuropatia Auditiva, com perda auditiva pré-lingual de grau severo ou profundo e usuárias de implante coclear. A pesquisa do potencial evocado auditivo cortical foi realizada com o estímulo de fala /da/, apresentado em campo livre, em três sessões de avaliação: na ativação dos eletrodos, com três e com seis meses após a ativação do implante coclear. Os registros obtidos foram analisados pela pesquisadora e por um juiz experiente em eletrofisiologia a fim de verificar a concordância das análises. Houve concordância de 100% (Kappa=1) entre os juízes quanto à ocorrência do componente P1, com coeficiente de correlação interclasse excelente para os valores de latência e amplitude. Quanto à morfologia, o componente P1 caracterizou-se como um pico positivo robusto na primeira sessão de avaliação. O componente P1 foi registrado em 71,43% da casuística na primeira sessão, em 87,50 % na segunda e em 85,71% na terceira sessão de avaliação. Nos pacientes em que foi possível observar o componente P1 em todas as sessões de avaliação, observou-se uma redução da latência considerando o primeiro e último momento de avaliação, contudo, os resultados mostraram-se heterogêneos entre as crianças avaliadas. Assim, na pesquisa do componente P1 do potencial evocado auditivo cortical, não foi possível determinar um padrão de comportamento deste componente em crianças com a Desordem do Espectro da Neuropatia Auditiva nos seis primeiros meses de uso do implante coclear. / Cochlear implants have been considered a rehabilitation option in patients with auditory neuropathy spectrum disorder. However, their indication is relatively recent, thus, few studies have investigated cortical development in these patients. So far, no longitudinal study has characterized the development of the central auditory system, following cochlear implant activation. This study aimed at characterizing P1 cortical auditory evoked potential in the first months of cochlear implant use, in children presented with auditory neuropathy spectrum disorder. Eight children diagnosed with auditory neuropathy spectrum disorder, with severe or profound pre-lingual hearing loss, users of cochlear implant, participated in this study. The cortical auditory evoked potential research was performed with the /da/ speech stimulus presented in free field, in three assessment sessions: at electrodes activation, at three and at six months, following cochlear implant activation. The recordings obtained were analyzed by the researcher and by an experienced electrophysiologist, so as to verify the agreement of the analyses. There was 100% agreement (Kappa=1) between the referees, as to the occurrence of component P1, with an excellent interclass correlation coefficient for latency and amplitude values. Regarding morphology, P1 was characterized as a robust positive peak in the first assessment session, being recorded in 71.43% of the sample, in the first session, in 87.50%, in the second, and in 85.71%, in the third. In patients in whom it was possible to observe P1 in all assessment sessions, a latency reduction was observed, considering the first and last time of evaluation, nevertheless, the results were shown to be heterogeneous among the children assessed. Thus, in the P1 cortical auditory evoked potential research, it was not possible to determine a behavior pattern of this component in children presented with auditory neuropathy spectrum disorder, in the first six months of cochlear implant use.
103

Freqüência de uso do aparelho de amplificação sonora individual associado ao implante coclear nos pacientes adultos do HCFMUSP / The frequency of use of the hearing aid associated to the cochlear implant in adult patients of HCFMUSP

Yamaguchi, Cintia Tizue 30 September 2009 (has links)
OBJETIVO: Identificar a freqüência do uso de AASI contralateral ao implante coclear (IC), determinar as razões de alguns pacientes não usarem AASI contralateral e verificar o efeito do resíduo de audição na opção de uso do AASI contralateral ao IC. MÉTODOS: estudo observacional, transversal com 82 pacientes adultos submetidos a um questionário. RESULTADOS: Nesta amostra 70 não-usuários foram identificados. A prevalência de usuários foi de 12%, com IC 95% (11-13%). A maioria dos não usuários (58,2%) relataram ausência de benefício com AASI, enquanto que 23,6% relataram não ter sido orientada a utilização. Usuários tinham média tonal de 107 dBNA, contra 117 dBNA entre os não usuários. CONCLUSÃO: O uso de AASI contralateral é raro nesta amostra, devido à falta audição residual ou benefício com a amplificação / OBJECTIVE: To identify the frequency of the use of hearing aid contralateral to the cochlear implant; to determine the reasons why some patients do not use a contralateral hearing aid; to check the effect of residual hearing in contralateral hearing aid (CHA) users. METHODS: observational, transversal study with 82 adult patients who were submitted to a questionnaire. RESULTS: In this sample 70 non-users were identified. The prevalence of CHA users was 12% with 95% CI (11-13%). Most CHA non users (58.2%) reported lack of benefit with hearing aids, while 23,6% reported not being referred to the use. CHA users had pure tone average of 107 dB HL, versus the 117 dB HL among non users. CONCLUSION: The use of contralateral hearing aid is rare in this sample due to lack residual hearing or benefit with the amplification
104

Desenvolvimento do sistema auditivo central em crianças com Espectro da Neuropatia Auditiva usuárias de implante coclear / Development of the central auditory system in cochlear implanted children with Auditory Neuropathy Spectrum

Amorim, Raquel Beltrão 28 February 2011 (has links)
O implante coclear tem sido indicado para a reabilitação de crianças com Espectro da Neuropatia Auditiva, com ampla variação no desempenho na percepção de fala. Caso o desenvolvimento das estruturas auditivas centrais não ocorra normalmente, pode-se presumir que as habilidades perceptuais que são a base para a percepção e produção da fala também não se desenvolverão normalmente. Nesse contexto, é possível questionar se a maneira como o sistema auditivo dessas crianças responde à estimulação elétrica após o período de privação sensorial poderia ser uma das justificativas para a variabilidade no resultado obtido com o implante coclear. O objetivo deste estudo foi caracterizar o componente P1 dos potenciais evocados auditivos de longa latência em indivíduos com Espectro da Neuropatia Auditiva usuários de implante coclear e correlacioná-los com o desempenho na percepção de fala e secundariamente a outras variáveis relacionadas ao implante coclear. Participaram do estudo 14 crianças com Espectro da Neuropatia Auditiva, usuárias de implante coclear, de ambos os sexos, na faixa etária de 4 a 11 anos. Foi realizada a pesquisa dos potenciais evocados auditivos de longa latência com estimulação acústica, utilizando estímulo de fala /da/ apresentado em campo livre, e a avaliação da percepção de fala por meio do protocolo GASP (BEVILACQUA; TECH, 1996). Como resultado, foi constatado que foi possível registrar o componente P1 em 85,7% desta população, sendo que o valor da latência do componente P1 apresentou correlação significante com o tempo de privação sensorial demonstrando que quanto maior o tempo de privação sensorial, maior a latência do componente P1. Não foi observada correlação significante entre o componente P1 e o tempo de uso do implante coclear. Foi observado que quando separados os indivíduos em grupos de acordo com o desempenho na percepção de fala, aqueles que apresentaram um melhor desempenho possuíam a latência do componente P1 estatisticamente menor, comparados ao de pior desempenho. Com os resultados obtidos neste estudo foi possível caracterizar o componente P1 dos potenciais evocados auditivos de longa latência em crianças com Espectro da Neuropatia Auditiva usuárias de implante coclear e demonstrar a correlação com o desempenho de percepção de fala e tempo de privação sensorial. Em crianças com Espectro da Neuropatia Auditiva, o componente P1 pode servir como um preditor do desempenho da criança usuária de implante coclear para a percepção de fala. / The cochlear implant has been recommended for the rehabilitation of children with Auditory Neuropathy Spectrum, with wide variation in performance in speech perception. If the development of central auditory structures does not occur normally, one can assume that the perceptual abilities that are the basis for the perception and speech production will not develop normally either. In this context one might question if the way the auditory system of these children respond to electrical stimulation after a period of sensory deprivation could be one of the reasons for this variability in the results obtained with the cochlear implant. The aim of this study was to characterize the P1 component of long-latency auditory evoked potentials in cochlear implanted individuals with Auditory Neuropathy Spectrum and correlate it with performance in speech perception and secondarily to other variables related to cochlear implant. The study included 14 cochlear implanted children with Auditory Neuropathy Spectrum, of both sexes, aged from four to eleven years. We studied the long-latency auditory evoked potential with acoustic stimulation, using speech stimuli presented in open field, and assessment of speech perception by means of GASP test (BEVILACQUA; TECH, 1996). As a result, we found that it was possible to register the P1 component in 85.7% of this population, and the P1 component latency value showed a significant correlation with the duration of sensory deprivation showing that the longer the duration of sensory deprivation, the greater the latency of the P1 component. There was no significant correlation between the P1 component and the time of cochlear implant use. It was observed that when the individuals were separated into groups according to performance on speech perception, those who performed better had the P1 component latency statistically lower when compared to the worst performers. With the results obtained from this study it was possible to characterize the P1 component of long-latency auditory evoked potentials in cochlear implanted children with Auditory Neuropathy Spectrum and demonstrate a correlation with the performance of speech perception. In children with Auditory Neuropathy Spectrum, the P1 component may serve as a predictor of the performance of a cochlear implanted child for speech perception.
105

Complexo P1-N1-P2 em usuários de implante coclear bilateral com ativação sequencial: estudo longitudinal em adolescentes

Maia, Thaís 31 August 2016 (has links)
O redirecionamento das estruturas auditivas centrais em pacientes que foram submetidos à cirurgia de implante coclear bilateral sequencial é pouco conhecido. Contudo, a pesquisa dos potenciais evocados auditivos corticais pode auxiliar na compreensão de como ocorrem o desenvolvimento, a plasticidade e a função cortical destes pacientes. Os objetivos deste trabalho foram caracterizar longitudinalmente o complexo P1-N1-P2 dos potenciais evocados auditivos corticais em usuários de implante coclear bilateral sequencial que realizaram a ativação do primeiro implante coclear na infância e a ativação do segundo dispositivo na adolescência; e analisar sua correlação com a percepção auditiva da fala. A casuística foi composta por indivíduos atendidos no Centro de Pesquisas Audiológicas, Seção de Implante Coclear, do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo, com perda auditiva pré-lingual e usuários de implante coclear bilateral. A pesquisa dos potenciais evocados auditivos corticais foi realizada com o estímulo de fala /da/, apresentado em campo livre em cinco momentos distintos: antes da cirurgia do segundo implante coclear, na ativação do segundo dispositivo e com três, seis e 12 meses após a ativação do segundo implante coclear. Os registros obtidos foram analisados pela pesquisadora e por um juiz experiente em eletrofisiologia a fim de verificar a concordância das análises. Houve concordância de 100% (Kappa=1) entre os juízes quanto à ocorrência dos componentes P1, N1 e P2, com coeficiente de correlação interclasse excelente para os valores de latência e amplitude. A resposta cortical obtida com o uso dos dois implantes cocleares ligados, aparentemente, reflete a melhor resposta cortical obtida, quanto à ocorrência e latência dos componentes, independente se registrada com o primeiro implante coclear ou com o segundo implante coclear ligado. Os componentes P1, N1 e P2 dos potenciais evocados auditivos corticais não são preditores dos resultados de percepção auditiva da fala tanto no silêncio quanto no ruído. / The redirection of central auditory structures in patients who underwent sequential bilateral cochlear implant surgery is little known. However, cortical auditory evoked potentials testing can aid in understanding how the development, the plasticity and cortical function of these patients, occur. This study aimed at characterizing, longitudinally, the P1-N1-P2 complex of cortical auditory evoked potentials in sequential bilateral cochlear implant users who had the first cochlear implant fitted in their childhood and the second device activated in their adolescence, and analyze its correlation with speech auditory perception. The sample consisted of individuals seen at the Audiological Research Center of the Craniofacial Anomalies Rehabilitation Hospital of the University of São Paulo, with pre-lingual hearing loss, users of bilateral cochlear implant. The cortical auditory evoked potentials research was performed with the /da/ speech stimulus, presented in free field, in five different times: before the second cochlear implant surgery, upon the fitting of the second device and three, six and 12 months following the activation of the second cochlear implant. The records obtained were analyzed by the researcher and by a judge experienced in electrophysiology, so as to verify the agreement of the analyses. A 100% agreement (kappa = 1) was seen between judges as to the occurrence of P1, N1 and P2, with an excellent inter-class correlation coefficient for the latency and amplitude values. The cortical response obtained with the use of the two cochlear implants, turned on, apparently reflects the best cortical response accomplished, as to the occurrence and latency of the components, regardless of being recorded with the first cochlear implant, or with the second one, turned on. The P1, N1 and P2 components of cortical auditory evoked potentials are not predictors of the results of auditory speech perception, both in silence and in noise.
106

Verificação eletroacústica de sistemas de frequência modulada em usuários de implante coclear / Electroacoustic verification of frequency modulation systems in cochlear implant users

Fidêncio, Vanessa Luisa Destro 06 July 2017 (has links)
O objetivo deste estudo foi realizar e determinar a validade de um protocolo de teste de verificação eletroacústica para Sistemas de Frequência Modulada (FM) acoplados a diferentes processadores de fala de implantes cocleares. Participaram deste estudo 40 crianças, com idades entre 5 e 18 anos incompletos, usuários de quatro modelos diferentes de processadores de fala. A verificação eletroacústica foi realizada por meio do uso do equipamento Audioscan Verifit (VF-1) com acoplador HA-1, além do uso do dispositivo de verificação de escuta correspondente a cada modelo de processador de fala do implante coclear. Nos casos em que a transparência não foi atingida, foi realizada alteração no ajuste do ganho do Sistema FM e avaliação da percepção auditiva da fala no ruído por meio da aplicação da versão brasileira do teste Phrases in Noise Test (PINT). Houve transparência entre o Sistema FM e o implante coclear em 85% dos dispositivos avaliados. Após o ajuste do ganho FM nos outros casos, os dispositivos apresentaram-se transparentes quando o teste de verificação eletroacústica foi repetido. Também foi observado que os participantes submetidos ao teste de percepção de fala no ruído apresentaram melhor desempenho após o novo ajuste, de modo que, nestes casos, a transparência eletroacústica ocasionou em transparência comportamental. Concluiuse que o protocolo de verificação eletroacústica utilizado mostrou-se efetivo para a avaliação da transparência entre o Sistema FM e o implante coclear. A realização prévia do ajuste do processador de fala e do ganho do Sistema FM mostrou-se essencial para que a transparência fosse atingida. / The purpose of this study was perform and determine the validity of an electroacoustic verification test for FM Systems coupled to different cochlear implant speech processors. The sample included 40 participants between 5-18 years users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, was made a modification in the FM gain adjustment and used the Brazilian version of the \"Phrases in Noise Test\" (PINT) to evaluate the speech perception in competitive noise. It was observed that there was transparency between the FM System and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the FM receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that they presented better performance in speech perception in noise after a new adjustment, that is, in these cases, the electroacoustic transparency caused behavioral transparency. It was concluded that the electroacoustic evaluation protocol suggested was effective to evaluate transparency between the FM System and the cochlear implant. Performing the adjustment of the speech processor and the FM System gain are essential when fitting this device.
107

The self-regulation of a child with cochlear implants within a school environment

Unknown Date (has links)
The purpose of this qualitative research, which utilized a narrative design strategy, was to describe the process of self-regulation of a child who has bilateral cochlear implants within the social environment of school. The study investigated the use of self-regulatory strategies by the cochlear implant recipient. It also examined how the child made modifications and monitored learning during activities within the classroom as related to Vygotsky's activity theory and John Dewey's theory of social control. Through data collection of documents, observations, interviews, and researcher field notes, it was found that the child demonstrated several self-regulatory strategies. / Kristin L. Patton. / Thesis (Ph.D.)--Florida Atlantic University, 2013. / Includes bibliography. / Mode of access: World Wide Web. / System requirements: Adobe Reader.
108

Desempenho de crianças pré-escolares, usuárias de implante coclear quanto ao desenvolvimento global, habilidades funcionais e linguagem / Performance of preschool children, cochlear implant users regarding global development, funcional skills and language

Scarabello, Emille Mayara 26 February 2015 (has links)
É amplamente reconhecido que o Implante Coclear (IC) é um tratamento eficaz para a perda auditiva sensorioneural severa e/ou profunda, embora complexo pela interação de variáveis que interferem no desempenho da criança que usa IC. No Brasil, poucos estudos relatam sobre o desenvolvimento de linguagem oral em relação aos diversos aspectos do desenvolvimento global nas áreas pessoal-social, motor fino-adaptativo, motor grosso e habilidades funcionais em indivíduos com perda auditiva. Diante ao exposto, este estudo propôs verificar o desempenho de crianças de 3 a 6 anos (incompletos) usuárias de implante coclear (IC) quanto às habilidades de desenvolvimento e linguagem oral. Trata-se de um estudo prospectivo transversal realizado no Departamento de Fonoaudiologia da Faculdade de Odontologia de Bauru e no Centro de Pesquisas Audiológicas (CPA) do Hospital de Anomalias Craniofaciais da Universidade de São Paulo na cidade de Bauru (HRAC/ USP-Bauru). Participaram 30 crianças usuárias de IC na faixa etária entre 03 e 06 anos. Os seguintes testes foram utilizados: Teste de linguagem infantil nas áreas de fonologia, vocabulário, fluência e pragmática (ABFW), Teste de Vocabulário de Imágenes Peabody, Denver Development Screening Test II DDST II e Inventário de Avaliação Pediátrica de Incapacidade PEDI. O tratamento estatístico constou de análise descritiva e aplicação dos seguintes testes: Teste de Normalidade de Kolmogorov-Smirnov, Teste de Correlação de Pearson, Teste de Correlação de Spearman, Teste de Kruskal-Wallis e Teste de Chi-square, com valores de significância p <0,005. Os resultados mostraram uma forte relação entre o desempenho das crianças participantes quanto a idade na cirurgia e ao tempo de uso de IC. A análise dos resultados mostrou que quanto melhor era o desempenho na linguagem oral, no desenvolvimento global e nas habilidades funcionais melhores eram os resultados nos testes de percepção da fala correlacionados, sendo que o desempenho da população estudada referente à linguagem oral era evidentemente pior que o desempenho nas áreas de avaliação motora, pessoal-social e autocuidados. / It is widely recognized that the cochlear implant is an effective treatment for severe/profound sensorineural hearing loss, although the complex interaction of variables that affect the performance of the child using cochlear implant. In Brazil, few studies have reported on the development of oral language on the various aspects of global development in the personal- social, fine motor-adaptive, gross motor and functional abilities in individuals with hearing loss. Given the above, this study aims to verify the performance of children 3-6 years (incomplete) users of cochlear implant about the skills and oral language development. This cross-sectional prospective study was conducted at the Department of Speech Pathology of Faculty of Dentistry of Bauru and Audiological Research Centre (CPA) of Hospital of Craniofacial Anomalies, University of São Paulo in Bauru (HRAC / USP-Bauru).Thirty children participated in this study using IC aged 3-6 years (incomplete). The following tests were used: Test of early language in the areas of phonology, vocabulary, fluency and pragmatics (ABFW), Peabody Picture Vocabulary Test (hispanoamericana adaptation), Denver Development Screening Test II DDST II and Pediatric Evaluation of Disability Inventory - PEDI. Statistical analysis consisted of descriptive analysis and application of the following tests: Normality Test Kolmogorov-Smirnov, Pearson\'s correlation Test, Spearman correlation Test, Kruskal-Wallis Test and Chi-square Test, with significance values of p <0.005. The results showed a strong relationship between the performance of children participating in age at surgery and the IC usage time. The results showed that the better was the performance in the oral language, in global development and better functional abilities were the results in speech perception tests correlated, and the performance of the studied population on the oral language was evidently worse than the in the areas of motor assessment, personal-social and self-care.
109

Reconhecimento de padrões auditivos de freqüência e de duração em crianças usuárias de implante coclear multicanal / Recognition of frequency and duration auditory patterns in children using multi-channel cochlear implant

Frederigue, Natália Barreto 30 June 2006 (has links)
A resolução temporal tem sido estudada em usuários de implante coclear (IC) de acordo com os novos algoritmos implementados nas estratégias de codificação da fala. O objetivo deste estudo foi determinar o perfil de desempenho de crianças usuárias de IC multicanal nas tarefas de detecção de seqüência temporal em dois testes comportamentais, Teste de Padrões de Freqüência (TPF) e Teste de Padrões de Duração (TPD). Avaliou-se 43 crianças usuárias de IC com idade entre 7 e 11 anos e 5 meses, regularmente matriculadas e acompanhadas no Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo. Destas 26 eram usuárias do IC Combi®40+ com a estratégia de codificação da fala Continuous Interleaved Sampler, cinco do IC Nucleus®24K e 12 do Nucleus®24M com a estratégia Advanced Combination Encoder, sendo 28 do gênero feminino e 15 do masculino. O tempo médio de surdez foi de 3 anos e o tempo médio de uso do IC de 4 anos e 9 meses. Ambos os testes foram aplicados em campo livre a 60 dBNA. As crianças foram solicitadas a responder por meio de respostas não verbal (NV) e verbal (V). O TPF constou da apresentação de uma seqüência de 3 tons com duração de 500 ms que diferiam na freqüência, 1430 Hz (alto) ou 880 Hz (baixo), perfazendo um total de 6 padrões distintos. O TPD constou da apresentação de uma seqüência de 3 tons de 1000 Hz que diferiam na duração, 500 ms (longo) ou 250 ms (curto), constituído também de 6 padrões de seqüências distintos. Foram apresentadas 10 repetições dos 6 padrões no total de 60 estímulos para TPD e TPF, em cada criança. Aplicou-se o mesmo protocolo de testes em 43 crianças, balanceadas em gênero e faixa etária, sem alterações de linguagem, fala, audição e/ou aprendizagem (grupo controle). Realizou-se análise estatística multivariada com o teste da razão de verossimilhança no modelo logístico ajustado e com testes de correlação. As análises evidenciaram que o desempenho no TPF com resposta NV foi significativamente superior à resposta V para todos os sujeitos, por outro lado observou-se diferença de desempenho entre as respostas NV e V apenas nas crianças entre 7 e 9 anos do grupo experimental. Constatou-se melhora significativa do desempenho com a idade para o TPDNV e TPDV (grupo experimental) e para o TPFV, TPDNV e TPDV (grupo controle). Todos os usuários do IC Combi®40+ apresentaram desempenho superior aos usuários do IC Nucleus®24K e Nucleus®24M em todas as condições avaliadas. Não houve correlações entre o desempenho e o tempo de uso do IC, tempo de surdez e teste de percepção da fala. Os sujeitos do gênero masculino apresentaram desempenhos superiores ao feminino para a maioria dos testes. O desempenho no TPF foi superior ao TPD. Neste estudo, as diferenças existentes em relação ao processamento do sinal nos IC devem ter interferido no desempenho das habilidades de ordenação temporal. Novas pesquisas são necessárias para complementação destes achados. / Temporal resolution has been studied in cochlear implant (CI) users, according to new algorithms implemented for speech coding strategies. The present study was aimed at determining the performance profile of multi-channel CI users in temporal-sequence detection tasks using pair of behavioral tests: frequency patterns test (FPT) and duration patterns test (DPT). Forty-three cochlear implanted children, age ranging from 7 to 11 yrs and 5 months, regularly enrolled and followed at the Audiological Research Center, the Craniofacial Anomalies Rehabilitation Hospital of the University of São Paulo, were evaluated. Twenty-six children were users of CI Combi®40+ with the Continuous Interleaved Sampler speech coding strategy; five of CI Nucleus®24K and twelve were users of Nucleus®24M with the Advanced Combination Encoder strategy; 28 were females, and 15 males. The mean auditory deprivation time was 3 years, and the mean CI use duration was 4 years and 9 months. Both tests were applied at 60 dBNA on free-field. Children were instructed to deliver answers through nonverbal (NV) and verbal (V) responses. FPT comprises the presentation of a three-tone sequence with a 500 ms duration which differed in the frequency: 1430 Hz (high) or 880 Hz (low), consisting of six distinct patterns. While DPT comprised the presentation of a three-tone sequence of 1000 Hz, which differed in the duration, either with 500 ms (long) or 250 ms (short), giving six distinct sequence patterns. Ten repetitions of six patterns totaling 60 stimuli for DPT and FPT were presented to each child. The same test protocol was applied to 43 children, balanced according to gender and age range, with no language, speech, hearing and/or learning alterations (control). Multivariate statistical analysis was used, with the likelihood ratio test to the adjusted logistic model, and correlation analysis. The analyses showed that the performance on FPT with a NV response was significantly superior to that of V response for all subjects. On the other hand, performance difference in between NV and V responses was observed only in the 7-9 year-old experimental group. Significant performance improvements with age were observed in NVDPT and VDPT for experimental group, as well as in VFPT, NVDPT and VDPT for control group. All users of CI Combi®40+ showed better performance compared to Nucleus®24K or Nucleus®24M users, for all assessed conditions. No correlations were found between performance and the use duration of CI, sensory deprivation time, and speech perception test result. Male subjects had a superior performance than females, for most of the tests. The performance on FPT was superior to that on DPT. In this study, the observed differences related to CI signal processing strategies must have interfered in the performance of temporal ordering abilities. Further research, to complement these findings, is necessary.
110

Freqüência de uso do aparelho de amplificação sonora individual associado ao implante coclear nos pacientes adultos do HCFMUSP / The frequency of use of the hearing aid associated to the cochlear implant in adult patients of HCFMUSP

Cintia Tizue Yamaguchi 30 September 2009 (has links)
OBJETIVO: Identificar a freqüência do uso de AASI contralateral ao implante coclear (IC), determinar as razões de alguns pacientes não usarem AASI contralateral e verificar o efeito do resíduo de audição na opção de uso do AASI contralateral ao IC. MÉTODOS: estudo observacional, transversal com 82 pacientes adultos submetidos a um questionário. RESULTADOS: Nesta amostra 70 não-usuários foram identificados. A prevalência de usuários foi de 12%, com IC 95% (11-13%). A maioria dos não usuários (58,2%) relataram ausência de benefício com AASI, enquanto que 23,6% relataram não ter sido orientada a utilização. Usuários tinham média tonal de 107 dBNA, contra 117 dBNA entre os não usuários. CONCLUSÃO: O uso de AASI contralateral é raro nesta amostra, devido à falta audição residual ou benefício com a amplificação / OBJECTIVE: To identify the frequency of the use of hearing aid contralateral to the cochlear implant; to determine the reasons why some patients do not use a contralateral hearing aid; to check the effect of residual hearing in contralateral hearing aid (CHA) users. METHODS: observational, transversal study with 82 adult patients who were submitted to a questionnaire. RESULTS: In this sample 70 non-users were identified. The prevalence of CHA users was 12% with 95% CI (11-13%). Most CHA non users (58.2%) reported lack of benefit with hearing aids, while 23,6% reported not being referred to the use. CHA users had pure tone average of 107 dB HL, versus the 117 dB HL among non users. CONCLUSION: The use of contralateral hearing aid is rare in this sample due to lack residual hearing or benefit with the amplification

Page generated in 0.8927 seconds