• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement d'un dosimètre diamant pour une mesure de la dose absorbée dans les mini-faisceaux utilisés en radiothérapie stéréotaxique. / Development of a diamond dosimeter for measuring the absorbed dose in small beams used in stereotactic radiotherapy

Marsolat, Fanny 10 January 2014 (has links)
La radiothérapie stéréotaxique est une technique de pointe relativement récente utilisée pour le traitement de tumeurs bénignes ou malignes de petites dimensions employant des mini-faisceaux. L'efficacité clinique de cette technique est prouvée et n'est pas remise en cause, cependant il n'existe pas actuellement de dosimètre véritablement approprié permettant de caractériser ces faisceaux de petites dimensions par des mesures précises de dose absolue et relative. Le problème du manque d'équilibre électronique latéral rencontré en mini-faisceaux entraîne principalement les contraintes suivantes pour le dosimètre : équivalence-eau et petit volume de détection. Les caractéristiques du diamant (faible numéro atomique Z=6, densité élevée d'atomes) en font un candidat idéal. Au cours de cette thèse, nous avons développé un prototype de dosimètre pour mini-faisceaux à partir de diamant monocristallin synthétique CVD. Les échantillons ont été caractérisés optiquement par différentes techniques et leurs propriétés de détection ont été étudiées sous rayonnement X et sous particules ?. Une série de premiers prototypes a été développée et testée sur plusieurs machines de stéréotaxie. Une étape d'optimisation de ces premiers dosimètres diamant a ensuite été réalisée notamment par l'utilisation de simulations Monte Carlo. L'optimisation des différents paramètres entrant en jeu dans la réponse du dosimètre en mini-faisceaux a permis d'aboutir à un prototype final de dosimètre diamant. Ce prototype répond au cahier des charges rédigé par les physiciens médicaux des centres hospitaliers, aussi bien en champs standards qu'en mini-faisceaux. / Stereotactic radiotherapy is a relatively recent technique used for the treatment of small benign and malignant tumors with small radiation beams. The clinical efficiency of this technique has been proved. However, the measurement of absolute and relative dose in small beams is not possible currently due to the lack of suited detectors for these measurements. In small beam dosimetry, the detector has to be as close as possible to tissue equivalence and exhibit a small detection volume due to the lack of lateral electronic equilibrium. Characteristics of diamond (water equivalent material Z=6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. In this thesis, we developed a dosimeter prototype for small beams, based on CVD synthetic single crystal diamond. The diamond samples were characterized optically and their detection properties were investigated under X-rays and alpha-particles. First diamond dosimeter prototypes were tested with small beams produced by several stereotactic machines. Studies using Monte Carlo simulations were performed in order to optimize the parameters involved in the detector response in small beams. This leaded to a final diamond dosimeter prototype that respects all radiotherapy centers requirements, in both standard and small beams.
2

Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels

Ghammraoui, Bahaa 20 September 2012 (has links) (PDF)
La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les distances inter-réticulaires pour les matériaux cristallins ou la fonction d'interférence moléculaire pour les matériaux amorphes. La méthode de diffraction par énergie dispersive (EDXRD), qui travaille à angle fixe avec un faisceau polychromatique et un détecteur résolu en énergie, est plus particulièrement adaptée à la problématique de contrôle de bagages, car elle permet d'envisager une architecture parallélisée pour imager un bagage complet en un temps raisonnable. Les travaux proposés dans cette thèse ont donc pour but d'étudier un système EDXRD utilisant un détecteur spectrométrique CdZnTe multi pixels pour l'identification des matériaux illicites dans les bagages. Une première étape a consisté à prendre en main cette technique à la fois expérimentalement avec un banc de diffraction mis à disposition et théoriquement par le biais du développement d'un outil de simulation élaboré. La confrontation entre l'expérimentation et la simulation a permis de bien comprendre la physique d'un tel système et de mieux analyser ses faiblesses pour pouvoir les corriger. En nous appuyant sur ces deux outils, nous avons ensuite étudié et mis en oeuvre de nouveaux concepts pour améliorer les performances du système EDXRD, en termes de résolution, d'intensité et de stabilité des pics de diffraction. Ainsi, une architecture novatrice, s'appuyant sur un traitement des signaux transitoires délivrés par les détecteurs CdZnTe, est proposée afin d'améliorer le compromis entre la résolution des pics de diffraction et leur intensité. Cette architecture est basée sur la sur-pixellisation du détecteur par la méthode de localisation barycentrique et sur une adaptation géométrique du système collimateur/détecteur. Enfin, le problème d'instabilité des pics de diffraction, due à l'effet d'orientation des grains des matériaux cristallins, est également traité.
3

Conception, reconstruction et évaluation d'une géométrie de collimation multi-focale en tomographie d'émission monophotonique préclinique

Benoit, Didier 05 December 2013 (has links) (PDF)
La tomographie d'émission monophotonique (TEMP) dédiée au petit animal est une technique d'imagerie nucléaire qui joue un rôle important en imagerie moléculaire. Les systèmes TEMP, à l'aide de collimateurs pinholes ou multi-pinholes, peuvent atteindre des résolutions spatiales submillimétriques et une haute sensibilité pour un petit champ de vue, ce qui est particulièrement attractif pour imager des souris. Une géométrie de collimation originale a été proposée, dans le cadre d'un projet, appelé SIGAHRS, piloté par la société Biospace. Ce collimateur présente des longueurs focales qui varient spatialement dans le plan transaxial et qui sont fixes dans le plan axial. Une haute résolution spatiale est recherchée au centre du champ de vue, avec un grand champ de vue et une haute sensibilité. Grâce aux simulations Monte Carlo, dont nous pouvons maîtriser tous les paramètres, nous avons étudié cette collimation originale que nous avons positionnée par rapport à un collimateur parallèle et un collimateur monofocal convergent. Afin de générer des données efficacement, nous avons développé un module multi-CPU/GPU qui utilise une technique de lancer de rayons dans le collimateur et qui nous a permis de gagner un facteur ~ 60 en temps de calcul, tout en conservant ~ 90 % du signal, pour l'isotope ⁹⁹^mTc (émettant à 140,5 keV), comparé à une simulation Monte Carlo classique. Cependant, cette approche néglige la pénétration septale et la diffusion dans le collimateur. Les données simulées ont ensuite été reconstruites avec l'algorithme OSEM. Nous avons développé quatre méthodes de projection (une projection simple (S-RT), une projection avec volume d'intersection (S-RT-IV), une projection avec calcul de l'angle solide (S-RT-SA) et une projection tenant compte de la profondeur d'interaction (S-RT-SA-D)). Nous avons aussi modélisé une PSF dans l'espace image, anisotrope et non-stationnaire, en nous inspirant de la littérature existante. Nous avons étudié le conditionnement de la matrice système pour chaque projecteur et collimateur, et nous avons comparé les images reconstruites pour chacun des collimateurs et pour chacun des projecteurs. Nous avons montré que le collimateur original proposé est le système le moins bien conditionné. Nous avons aussi montré que la modélisation de la PSF dans l'image ainsi que de la profondeur d'intéraction améliorent la qualité des images reconstruites ainsi que le recouvrement de contraste. Cependant, ces méthodes introduisent des artefacts de bord. Comparé aux systèmes existants, nous montrons que ce nouveau collimateur a un grand champ de vue (~ 70 mm dans le plan transaxial), avec une résolution de 1,0 mm dans le meilleur des cas, mais qu'il a une sensibilité relativement faible (1,32x10⁻² %).
4

Optimisation et validation des méthodes de calcul de dose à distance des faisceaux d’irradiation pour leur application dans les études épidémiologiques et cliniques en radiothérapie / Optimization and validation of out-of-field dose calculation methods in external beam radiation therapy for use in epidemiological and clinical studies

Vũ Bezin, Jérémi 17 December 2015 (has links)
La proportion de survivants à un cancer dans la population des pays développés augmente rapidement. Dans plus de la moitié des cas, la radiothérapie a été une composante de leur traitement. Les rayons ionisants alors administrés peuvent induire de graves conséquences à long terme, en particulier les cancers radio-induits et les maladies cardiovasculaires. Ces évènements sont dus non seulement aux fortes doses administrées au volume cible, mais également aux doses plus faibles, de quelques milligray à quelques gray, non souhaitées, mais inévitablement administrées dans le reste du corps du patient par la dose hors champ. L’évolution des techniques de planification du traitement et de l’informatique en médecine permettent aujourd’hui d’obtenir, systématiquement, l’évaluation précise des doses les plus fortes administrées au patient. Les doses faibles à intermédiaires administrées en dehors du faisceau de traitement, ne sont pour leur part, ni habituellement prises en compte, ni correctement évaluées par les systèmes actuels de planification du traitement. L’objectif de ce travail était de proposer des méthodes pour estimer le rayonnement hors champ des faisceaux de photons des accélérateurs de radiothérapie externe. L’utilisation d’une bibliothèque graphique nous a permis de réaliser une représentation géométrique 3D partielle des appareils de traitement et des sources photoniques responsables de la dose reçue par le patient. Nous avons déterminé l’intensité de ces sources en utilisant des mesures réalisées dans des champs simples. Le modèle ainsi calibré permettait de simuler la variation de l’intensité des sources en fonction de la taille du champ. Cette approche a permis de décrire avec succès la variation de la dose mesurée par TLD en fonction de la distance et de la taille du champ en dehors de champs carrés. Les écarts entres les doses calculées et celles mesurées étaient inférieurs à 10 %. Une application dans des conditions cliniques a été menée, l’écart était alors en moyenne de 25 %. / The number of cancer survivors in developed counties increases rapidly. Fifty percent of patients treated for cancer will receive radiation therapy as part of their treatment. Ionizing radiation may induce severe long term effects, including secondary cancers and cardio-vascular diseases. Long term effects are not only due to high doses delivered in target volumes, but also to lower doses, ranging from several milligrays to several grays, undesired, but inevitably delivered in the rest of the patient’s body outside the treatment beams. Improvements in treatment planning technics and the use of computers in medicine made it possible to systematically estimate, prior to treatment, the highest doses delivered to the patient’s body. However, lower doses delivered outside the treatment beams are neither taken into account nor evaluated by present treatment planning systems. The aim of our work was to establish methods to estimate radiation doses outside photon beams from accelerators used in external radiation therapy. A graphics library was used to render a partial 3D representation of the accelerator and the photon sources associated. The intensity of these sources was determined using measurements performed in simple geometry fields. The calibrated model was hence used to estimate the source intensity variation with respect to field size. Using this method, we were able to estimate the variations of the TLD measured doses with respect to distance and field size with a 10% average discrepancy between calculations and measurements for points outside the field. Also, when testing the model in a clinical setup, the average discrepancy increased to 25%.
5

Conception, reconstruction et évaluation d'une géométrie de collimation multi-focale en tomographie d'émission monophotonique préclinique / Design, reconstruction and evaluation of multi-focal collimation in single photon emission computed tomography for small-animal imaging

Benoit, Didier 05 December 2013 (has links)
La tomographie d'émission monophotonique (TEMP) dédiée au petit animal est une technique d'imagerie nucléaire qui joue un rôle important en imagerie moléculaire. Les systèmes TEMP, à l'aide de collimateurs pinholes ou multi-pinholes, peuvent atteindre des résolutions spatiales submillimétriques et une haute sensibilité pour un petit champ de vue, ce qui est particulièrement attractif pour imager des souris. Une géométrie de collimation originale a été proposée, dans le cadre d'un projet, appelé SIGAHRS, piloté par la société Biospace. Ce collimateur présente des longueurs focales qui varient spatialement dans le plan transaxial et qui sont fixes dans le plan axial. Une haute résolution spatiale est recherchée au centre du champ de vue, avec un grand champ de vue et une haute sensibilité. Grâce aux simulations Monte Carlo, dont nous pouvons maîtriser tous les paramètres, nous avons étudié cette collimation originale que nous avons positionnée par rapport à un collimateur parallèle et un collimateur monofocal convergent. Afin de générer des données efficacement, nous avons développé un module multi-CPU/GPU qui utilise une technique de lancer de rayons dans le collimateur et qui nous a permis de gagner un facteur ~ 60 en temps de calcul, tout en conservant ~ 90 % du signal, pour l'isotope ⁹⁹^mTc (émettant à 140,5 keV), comparé à une simulation Monte Carlo classique. Cependant, cette approche néglige la pénétration septale et la diffusion dans le collimateur. Les données simulées ont ensuite été reconstruites avec l'algorithme OSEM. Nous avons développé quatre méthodes de projection (une projection simple (S-RT), une projection avec volume d'intersection (S-RT-IV), une projection avec calcul de l'angle solide (S-RT-SA) et une projection tenant compte de la profondeur d'interaction (S-RT-SA-D)). Nous avons aussi modélisé une PSF dans l'espace image, anisotrope et non-stationnaire, en nous inspirant de la littérature existante. Nous avons étudié le conditionnement de la matrice système pour chaque projecteur et collimateur, et nous avons comparé les images reconstruites pour chacun des collimateurs et pour chacun des projecteurs. Nous avons montré que le collimateur original proposé est le système le moins bien conditionné. Nous avons aussi montré que la modélisation de la PSF dans l'image ainsi que de la profondeur d'intéraction améliorent la qualité des images reconstruites ainsi que le recouvrement de contraste. Cependant, ces méthodes introduisent des artefacts de bord. Comparé aux systèmes existants, nous montrons que ce nouveau collimateur a un grand champ de vue (~ 70 mm dans le plan transaxial), avec une résolution de 1,0 mm dans le meilleur des cas, mais qu'il a une sensibilité relativement faible (1,32x10⁻² %). / Small animal single photon emission computed tomography (SPECT) is a nuclear medicine imaging technique that plays an important role in molecular imaging. SPECT systems using pinhole or multi-pinhole collimator can achieve submillimetric spatial resolution and high sensitivity in a small field of view, which is particularly appropriate for imaging mice. In our work, we studied a new collimator dedicated to small animal SPECT, in the context of a project called SIGAHRS, led by the Biospace company. In this collimator, focal lengths vary spatially in the transaxial plane and are fixed in the axial plane. This design aims at achieving high spatial resolution in the center of the field of view, with a large field of view and high sensitivity. Using Monte Carlo simulations, where all parameters can be controlled, we studied this new collimator geometry and compared it to a parallel collimator and a cone-beam collimator. To speed up the simulations, we developed a multi-CPU/GPU module that uses a technique of ray tracing. Using this approach, the acceleration factor was ~ 60 and we restored ~ 90 % of the signal for ⁹⁹^mTc (140.5 keV emission), compared to a classical Monte Carlo simulation. The 10 % difference is due to the fact that the multi-CPU/GPU module neglects the septal penetration and scatter in the collimator. We demonstrated that the data acquired with the new collimator could be reconstructed without artifact using an OSEM algorithm. We developed four forward projectors (simple projector (S-RT), projector accounting for the surface of the detecting pixel (S-RT-IV), projection modeling the solid angle (S-RT-SA) of the projection tube, and projector modeling the depth of interaction (S-RT-SA-D)). We also modeled the point spread function of the collimator in the image domain, using an anisotropic non-stationary function. To characterize the reconstruction, we studied the conditioning number of the system matrix for each projector and each collimator. We showed that the new collimator was more ill-conditioned than a parallel collimator or a cone-beam collimator. We showed that the image based PSF and the modeling of the depth of interaction improved the quality of the images, but edge artefacts were introduced when modeling the PSF in the image domain. Compared to existing systems, we showed that this new collimator has a large field of view (~ 70 mm in the transaxial plane) with a resolution of 1.0 mm in the best case but suffers from a relatively low sensitivity (1.32x10⁻² %).
6

Développement d'un dosimètre diamant pour une mesure de la dose absorbée dans les mini-faisceaux utilisés en radiothérapie stéréotaxique.

Marsolat, Fanny 10 January 2014 (has links) (PDF)
La radiothérapie stéréotaxique est une technique de pointe relativement récente utilisée pour le traitement de tumeurs bénignes ou malignes de petites dimensions employant des mini-faisceaux. L'efficacité clinique de cette technique est prouvée et n'est pas remise en cause, cependant il n'existe pas actuellement de dosimètre véritablement approprié permettant de caractériser ces faisceaux de petites dimensions par des mesures précises de dose absolue et relative. Le problème du manque d'équilibre électronique latéral rencontré en mini-faisceaux entraîne principalement les contraintes suivantes pour le dosimètre : équivalence-eau et petit volume de détection. Les caractéristiques du diamant (faible numéro atomique Z=6, densité élevée d'atomes) en font un candidat idéal. Au cours de cette thèse, nous avons développé un prototype de dosimètre pour mini-faisceaux à partir de diamant monocristallin synthétique CVD. Les échantillons ont été caractérisés optiquement par différentes techniques et leurs propriétés de détection ont été étudiées sous rayonnement X et sous particules ?. Une série de premiers prototypes a été développée et testée sur plusieurs machines de stéréotaxie. Une étape d'optimisation de ces premiers dosimètres diamant a ensuite été réalisée notamment par l'utilisation de simulations Monte Carlo. L'optimisation des différents paramètres entrant en jeu dans la réponse du dosimètre en mini-faisceaux a permis d'aboutir à un prototype final de dosimètre diamant. Ce prototype répond au cahier des charges rédigé par les physiciens médicaux des centres hospitaliers, aussi bien en champs standards qu'en mini-faisceaux.
7

Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels / Study of a system for the identification of materials by energy dispersive X-ray diffraction

Ghammraoui, Bahaa 20 September 2012 (has links)
La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les distances inter-réticulaires pour les matériaux cristallins ou la fonction d'interférence moléculaire pour les matériaux amorphes. La méthode de diffraction par énergie dispersive (EDXRD), qui travaille à angle fixe avec un faisceau polychromatique et un détecteur résolu en énergie, est plus particulièrement adaptée à la problématique de contrôle de bagages, car elle permet d'envisager une architecture parallélisée pour imager un bagage complet en un temps raisonnable. Les travaux proposés dans cette thèse ont donc pour but d'étudier un système EDXRD utilisant un détecteur spectrométrique CdZnTe multi pixels pour l'identification des matériaux illicites dans les bagages. Une première étape a consisté à prendre en main cette technique à la fois expérimentalement avec un banc de diffraction mis à disposition et théoriquement par le biais du développement d'un outil de simulation élaboré. La confrontation entre l'expérimentation et la simulation a permis de bien comprendre la physique d'un tel système et de mieux analyser ses faiblesses pour pouvoir les corriger. En nous appuyant sur ces deux outils, nous avons ensuite étudié et mis en oeuvre de nouveaux concepts pour améliorer les performances du système EDXRD, en termes de résolution, d'intensité et de stabilité des pics de diffraction. Ainsi, une architecture novatrice, s'appuyant sur un traitement des signaux transitoires délivrés par les détecteurs CdZnTe, est proposée afin d'améliorer le compromis entre la résolution des pics de diffraction et leur intensité. Cette architecture est basée sur la sur-pixellisation du détecteur par la méthode de localisation barycentrique et sur une adaptation géométrique du système collimateur/détecteur. Enfin, le problème d'instabilité des pics de diffraction, due à l'effet d'orientation des grains des matériaux cristallins, est également traité. / X-ray diffraction is becoming a prevailing technique for non invasive inspection of luggage. Compared to traditional techniques of transmission imaging, the diffraction technique can extract more characteristic information of materials, such as the Bragg peaks for crystalline materials or the molecular interference function for amorphous materials. The method of energy dispersive X Ray diffraction (EDXRD), which works at a fixed low scatter angle but with a polychromatic X-ray beam and a energy resolved detector, is particularly suited to the problem of luggage control as it allows parallelized architectures to inspect an entire object in a reasonable time. The work proposed in this thesis is to study an EDXRD system using a multi-pixelated CdZnTe detector to identify illicit materials in baggage. A first step has been to take control of this technique both experimentally with a diffraction bench and theoretically through the development of an elaborate simulation tool. The comparison between experiment and simulation has allowed to understand the physics of such a system and to better analyze its weaknesses to correct them. Relying on these two tools, we studied and implemented new concepts to improve performances of EDXRD systems, in terms of resolution, intensity and stability of the diffraction peaks. Thus, an innovative architecture, based on a dedicated treatment of transient signals delivered by the CdZnTe detectors, is proposed to significantly improve the compromise between the resolution of the diffraction peaks and their intensity. This architecture is based on an over-pixelation (1D) of the detector by an electronic positioning method and on a geometric adaptation of the system collimator/detector. The problem of instability of the diffraction peaks due to the effect of grain orientation in crystals is also handled.

Page generated in 0.065 seconds