• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels

Ghammraoui, Bahaa 20 September 2012 (has links) (PDF)
La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les distances inter-réticulaires pour les matériaux cristallins ou la fonction d'interférence moléculaire pour les matériaux amorphes. La méthode de diffraction par énergie dispersive (EDXRD), qui travaille à angle fixe avec un faisceau polychromatique et un détecteur résolu en énergie, est plus particulièrement adaptée à la problématique de contrôle de bagages, car elle permet d'envisager une architecture parallélisée pour imager un bagage complet en un temps raisonnable. Les travaux proposés dans cette thèse ont donc pour but d'étudier un système EDXRD utilisant un détecteur spectrométrique CdZnTe multi pixels pour l'identification des matériaux illicites dans les bagages. Une première étape a consisté à prendre en main cette technique à la fois expérimentalement avec un banc de diffraction mis à disposition et théoriquement par le biais du développement d'un outil de simulation élaboré. La confrontation entre l'expérimentation et la simulation a permis de bien comprendre la physique d'un tel système et de mieux analyser ses faiblesses pour pouvoir les corriger. En nous appuyant sur ces deux outils, nous avons ensuite étudié et mis en oeuvre de nouveaux concepts pour améliorer les performances du système EDXRD, en termes de résolution, d'intensité et de stabilité des pics de diffraction. Ainsi, une architecture novatrice, s'appuyant sur un traitement des signaux transitoires délivrés par les détecteurs CdZnTe, est proposée afin d'améliorer le compromis entre la résolution des pics de diffraction et leur intensité. Cette architecture est basée sur la sur-pixellisation du détecteur par la méthode de localisation barycentrique et sur une adaptation géométrique du système collimateur/détecteur. Enfin, le problème d'instabilité des pics de diffraction, due à l'effet d'orientation des grains des matériaux cristallins, est également traité.
2

Imagerie par rayons X résolue en énergie : Méthodes de décomposition en base de matériaux adaptées à des détecteurs spectrométriques / Energy-resolved X-ray Imaging : Material decomposition methods adapted for spectrometric detectors

Potop, Alexandra-Iulia 02 October 2014 (has links)
Les systèmes d’imagerie par rayons X conventionnels utilisent des détecteurs à base de scintillateur en mode intégration d’énergie. La nouvelle génération de détecteurs à base de semi-conducteur CdTe/CdZnTe permet de compter le nombre de photons et de mesurer l’énergie avec laquelle les photons arrivent sur le détecteur. Le laboratoire LDET (CEA LETI) a développé des détecteurs spectrométriques pixellisés à base de CdTe pour l’imagerie par rayons X associés à un circuit de lecture rapide permettant de travailler à fort taux de comptage avec une bonne résolution en énergie. Ces travaux de thèse proposent d’apporter une contribution au traitement des données acquises sur ces détecteurs résolus en énergie pour la quantification des constituants des matériaux en radiographie et en tomographie. Le cadre médical applicatif choisi est l’ostéodensitométrie. Des simulations de radiographie, qui prennent en compte les imperfections du système de détection, comme le partage de charges et les empilements, ont été réalisées. Nous avons choisi d’étudier des méthodes de traitements des données spectrales basées sur la décomposition en base de matériaux. Cette technique de réduction des données consiste à modéliser le coefficient d’atténuation linéique d’un matériau par une combinaison linéaire des fonctions d’atténuation de deux matériaux de base. Deux approches, utilisant toutes les deux un apprentissage par calibrage, ont été adaptées pour notre application. La première est une adaptation de l’approche polynômiale standard, appliquée pour deux et trois canaux d’énergie. Un processus d’optimisation des seuils des canaux a été réalisé afin de trouver la configuration optimale des bandes d’énergie. Une étude sur le nombre de canaux a permis d’évaluer les limites de la formulation polynômiale. Pour aller plus loin dans l’exploitation du potentiel des nouveaux détecteurs, une approche statistique développée dans notre laboratoire a été adaptée pour la décomposition en base de matériaux. Elle peut se généraliser à un grand nombre de canaux (100 par exemple). Une comparaison des deux approches a été réalisée selon des critères de performance comme le bruit et la précision sur l’estimation des longueurs des matériaux traversés. La validation des deux approches étudiées sur des données expérimentales acquises en radiographie, dans notre laboratoire, avec des détecteurs spectrométriques, a montré une bonne quantification des constituants des matériaux, en accord avec les résultats obtenus en simulation. / Scintillator based integrating detectors are used in conventional X-ray imaging systems. The new generation of energy-resolved semiconductor radiation detectors, based on CdTe/CdZnTe, allows counting the number of photons incident on the detector and measure their energy. The LDET laboratory developed pixelated spectrometric detectors for X-ray imaging, associated with a fast readout circuit, which allows working with high fluxes and while maintaining a good energy resolution. With this thesis, we bring our contribution to data processing acquired in radiographic and tomographic modes for material components quantification. Osteodensitometry was chosen as a medical application. Radiographic data was acquired by simulation with a detector which presents imperfections as charge sharing and pile-up. The methods chosen for data processing are based on a material decomposition approach. Basis material decomposition models the linear attenuation coefficient of a material as a linear combination of the attenuations of two basis materials based on the energy related information acquired in each energy bin. Two approaches based on a calibration step were adapted for our application. The first is the polynomial approach used for standard dual energy acquisitions, which was applied for two and three energies acquired with the energy-resolved detector. We searched the optimal configuration of bins. We evaluated the limits of the polynomial approach with a study on the number of channels. To go further and take benefit of the elevated number of bins acquired with the detectors developed in our laboratory, a statistical approach implemented in our laboratory was adapted for the material decomposition method for quantifying mineral content in bone. The two approaches were compared using figures of merit as bias and noise over the lengths of the materials traversed by X-rays. An experimental radiographic validation of the two approaches was done in our laboratory with a spectrometric detector. Results in material quantification reflect an agreement with the simulations.
3

Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels / Study of a system for the identification of materials by energy dispersive X-ray diffraction

Ghammraoui, Bahaa 20 September 2012 (has links)
La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les distances inter-réticulaires pour les matériaux cristallins ou la fonction d'interférence moléculaire pour les matériaux amorphes. La méthode de diffraction par énergie dispersive (EDXRD), qui travaille à angle fixe avec un faisceau polychromatique et un détecteur résolu en énergie, est plus particulièrement adaptée à la problématique de contrôle de bagages, car elle permet d'envisager une architecture parallélisée pour imager un bagage complet en un temps raisonnable. Les travaux proposés dans cette thèse ont donc pour but d'étudier un système EDXRD utilisant un détecteur spectrométrique CdZnTe multi pixels pour l'identification des matériaux illicites dans les bagages. Une première étape a consisté à prendre en main cette technique à la fois expérimentalement avec un banc de diffraction mis à disposition et théoriquement par le biais du développement d'un outil de simulation élaboré. La confrontation entre l'expérimentation et la simulation a permis de bien comprendre la physique d'un tel système et de mieux analyser ses faiblesses pour pouvoir les corriger. En nous appuyant sur ces deux outils, nous avons ensuite étudié et mis en oeuvre de nouveaux concepts pour améliorer les performances du système EDXRD, en termes de résolution, d'intensité et de stabilité des pics de diffraction. Ainsi, une architecture novatrice, s'appuyant sur un traitement des signaux transitoires délivrés par les détecteurs CdZnTe, est proposée afin d'améliorer le compromis entre la résolution des pics de diffraction et leur intensité. Cette architecture est basée sur la sur-pixellisation du détecteur par la méthode de localisation barycentrique et sur une adaptation géométrique du système collimateur/détecteur. Enfin, le problème d'instabilité des pics de diffraction, due à l'effet d'orientation des grains des matériaux cristallins, est également traité. / X-ray diffraction is becoming a prevailing technique for non invasive inspection of luggage. Compared to traditional techniques of transmission imaging, the diffraction technique can extract more characteristic information of materials, such as the Bragg peaks for crystalline materials or the molecular interference function for amorphous materials. The method of energy dispersive X Ray diffraction (EDXRD), which works at a fixed low scatter angle but with a polychromatic X-ray beam and a energy resolved detector, is particularly suited to the problem of luggage control as it allows parallelized architectures to inspect an entire object in a reasonable time. The work proposed in this thesis is to study an EDXRD system using a multi-pixelated CdZnTe detector to identify illicit materials in baggage. A first step has been to take control of this technique both experimentally with a diffraction bench and theoretically through the development of an elaborate simulation tool. The comparison between experiment and simulation has allowed to understand the physics of such a system and to better analyze its weaknesses to correct them. Relying on these two tools, we studied and implemented new concepts to improve performances of EDXRD systems, in terms of resolution, intensity and stability of the diffraction peaks. Thus, an innovative architecture, based on a dedicated treatment of transient signals delivered by the CdZnTe detectors, is proposed to significantly improve the compromise between the resolution of the diffraction peaks and their intensity. This architecture is based on an over-pixelation (1D) of the detector by an electronic positioning method and on a geometric adaptation of the system collimator/detector. The problem of instability of the diffraction peaks due to the effect of grain orientation in crystals is also handled.

Page generated in 0.0603 seconds