• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels

Ghammraoui, Bahaa 20 September 2012 (has links) (PDF)
La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les distances inter-réticulaires pour les matériaux cristallins ou la fonction d'interférence moléculaire pour les matériaux amorphes. La méthode de diffraction par énergie dispersive (EDXRD), qui travaille à angle fixe avec un faisceau polychromatique et un détecteur résolu en énergie, est plus particulièrement adaptée à la problématique de contrôle de bagages, car elle permet d'envisager une architecture parallélisée pour imager un bagage complet en un temps raisonnable. Les travaux proposés dans cette thèse ont donc pour but d'étudier un système EDXRD utilisant un détecteur spectrométrique CdZnTe multi pixels pour l'identification des matériaux illicites dans les bagages. Une première étape a consisté à prendre en main cette technique à la fois expérimentalement avec un banc de diffraction mis à disposition et théoriquement par le biais du développement d'un outil de simulation élaboré. La confrontation entre l'expérimentation et la simulation a permis de bien comprendre la physique d'un tel système et de mieux analyser ses faiblesses pour pouvoir les corriger. En nous appuyant sur ces deux outils, nous avons ensuite étudié et mis en oeuvre de nouveaux concepts pour améliorer les performances du système EDXRD, en termes de résolution, d'intensité et de stabilité des pics de diffraction. Ainsi, une architecture novatrice, s'appuyant sur un traitement des signaux transitoires délivrés par les détecteurs CdZnTe, est proposée afin d'améliorer le compromis entre la résolution des pics de diffraction et leur intensité. Cette architecture est basée sur la sur-pixellisation du détecteur par la méthode de localisation barycentrique et sur une adaptation géométrique du système collimateur/détecteur. Enfin, le problème d'instabilité des pics de diffraction, due à l'effet d'orientation des grains des matériaux cristallins, est également traité.
2

Etude d'un système d'identification de matériaux par diffraction de rayons X à partir d'acquisitions spectrométriques multi pixels / Study of a system for the identification of materials by energy dispersive X-ray diffraction

Ghammraoui, Bahaa 20 September 2012 (has links)
La diffraction des rayons X apparait comme une modalité prometteuse pour l'inspection non invasive de bagages. Par comparaison aux techniques traditionnelles d'imagerie par transmission, cette technique permet de révéler davantage d'informations caractéristiques sur les matériaux, comme les distances inter-réticulaires pour les matériaux cristallins ou la fonction d'interférence moléculaire pour les matériaux amorphes. La méthode de diffraction par énergie dispersive (EDXRD), qui travaille à angle fixe avec un faisceau polychromatique et un détecteur résolu en énergie, est plus particulièrement adaptée à la problématique de contrôle de bagages, car elle permet d'envisager une architecture parallélisée pour imager un bagage complet en un temps raisonnable. Les travaux proposés dans cette thèse ont donc pour but d'étudier un système EDXRD utilisant un détecteur spectrométrique CdZnTe multi pixels pour l'identification des matériaux illicites dans les bagages. Une première étape a consisté à prendre en main cette technique à la fois expérimentalement avec un banc de diffraction mis à disposition et théoriquement par le biais du développement d'un outil de simulation élaboré. La confrontation entre l'expérimentation et la simulation a permis de bien comprendre la physique d'un tel système et de mieux analyser ses faiblesses pour pouvoir les corriger. En nous appuyant sur ces deux outils, nous avons ensuite étudié et mis en oeuvre de nouveaux concepts pour améliorer les performances du système EDXRD, en termes de résolution, d'intensité et de stabilité des pics de diffraction. Ainsi, une architecture novatrice, s'appuyant sur un traitement des signaux transitoires délivrés par les détecteurs CdZnTe, est proposée afin d'améliorer le compromis entre la résolution des pics de diffraction et leur intensité. Cette architecture est basée sur la sur-pixellisation du détecteur par la méthode de localisation barycentrique et sur une adaptation géométrique du système collimateur/détecteur. Enfin, le problème d'instabilité des pics de diffraction, due à l'effet d'orientation des grains des matériaux cristallins, est également traité. / X-ray diffraction is becoming a prevailing technique for non invasive inspection of luggage. Compared to traditional techniques of transmission imaging, the diffraction technique can extract more characteristic information of materials, such as the Bragg peaks for crystalline materials or the molecular interference function for amorphous materials. The method of energy dispersive X Ray diffraction (EDXRD), which works at a fixed low scatter angle but with a polychromatic X-ray beam and a energy resolved detector, is particularly suited to the problem of luggage control as it allows parallelized architectures to inspect an entire object in a reasonable time. The work proposed in this thesis is to study an EDXRD system using a multi-pixelated CdZnTe detector to identify illicit materials in baggage. A first step has been to take control of this technique both experimentally with a diffraction bench and theoretically through the development of an elaborate simulation tool. The comparison between experiment and simulation has allowed to understand the physics of such a system and to better analyze its weaknesses to correct them. Relying on these two tools, we studied and implemented new concepts to improve performances of EDXRD systems, in terms of resolution, intensity and stability of the diffraction peaks. Thus, an innovative architecture, based on a dedicated treatment of transient signals delivered by the CdZnTe detectors, is proposed to significantly improve the compromise between the resolution of the diffraction peaks and their intensity. This architecture is based on an over-pixelation (1D) of the detector by an electronic positioning method and on a geometric adaptation of the system collimator/detector. The problem of instability of the diffraction peaks due to the effect of grain orientation in crystals is also handled.
3

Élaboration et caractérisation 3D de l’endommagement dans les composites amorphe-cristallins métalliques / Elaboration and 3D damage characterization in amorphous-cristalline composite

Ferré, Antoine 06 May 2015 (has links)
Les verres métalliques ont commencé à être produit dans les années 1960 et sous forme massive dans les années 1980. De nombreuses études se sont intéressées à ces matériaux sous leur forme amorphe et ont conclu qu’ils avaient une forte résistance mécanique mais présentaient un comportement très fragile. Dans le cadre du projet EDDAM débuté en 2011, ces matériaux ont été introduits sous forme de petites sphères dans une matrice d’aluminium. Le premier objectif de notre étude est de voir si le verre métallique sous cette forme permet de le rendre peu fragile. Le second objectif est de trouver une alternative aux renforts céramique dans les composites à matrice métallique qui présentent une faible cohésion à l’interface matrice/inclusion. Dans le but de caractériser l’endommagement dans des nouveaux composites amorphe-cristallins métalliques, la tomographie aux rayons X a été utilisée. Cette technique permet de caractériser de manière non destructive l’endommagement des matériaux et de le visualiser en 3D. Cela apporte une contribution à l’étude des matériaux composites par rapport aux techniques classiques utilisées. L’objectif général de cette thèse a été d’étudier l’endommagement en termes d’amorçage, de croissance et de coales- cence des matériaux composites amorphe-cristallins métallique par tomographie aux rayons X lors d’essais de traction monotone in situ. Les matériaux sélectionnés sont constitués d’une matrice aluminium ("molle" de type 1070A ou "dure" de type 5083) et de renforts en verre métallique Zr57Cu20Al10Ni8Ti5 de taille peu dispersée et répartis de manière homogène, avec différentes fractions volumiques (1%, 4% et 10%). Les matériaux composites ont été élaborés par la voie de la métallurgie des poudres au Spark Plasma Sintering (SPS) suivi d’une étape d’extrusion à chaud. Une attention particulière a été portée sur la caractérisation microstructurale des constituants de base. L’analyse qualitative a permis de comparer l’ensemble des composites fabriqués au SPS et ceux extrudés à chaud après SPS. Les différents modes d’amorçage de l’endommagement ont été observés ainsi que la croissance et la coa- lescence amenant la rupture des composites. L’analyse quantitative a été essentiellement consacrée au premier stade de l’endommagement. La croissance et la coalescence étant très rapide, il a été difficile de les suivre lors des essais interrompus. La modélisation d’un composite amorphe-cristallin métallique à matrice molle a été introduite dans le but de reproduire l’endommagement observé lors des analyses expérimentales. Cette première approche nécessite d’être approfondie dans le but de prédire, compte tenu des propriétés mécaniques des différentes phases et de la fraction volumique des renforts, le mode d’endommagement préférentiel apparaissant dans les composites étudiés. Elle montre cependant les prémices d’une modélisation innovante basée sur la microstructure expérimentale. / Metallic glasses have been produced in the 1960s and bulk metallic glasses in the 1980s. Many studies, focused on these materials in their amorphous state, concluded that they had high mechanical strength but shown low ductility. As part of EDDAM project that started in 2011, these materials were introduced as small particles in an aluminum matrix. The first objective of this study is to see if the metallic glass is less brittle in this form. The second objective is to find an alternative of ceramic reinforcements in metal matrix composites. These materials have low cohesion at the matrix/inclusion interface. In order to characterize the damage in new amorphous-crystalline composite, X-ray tomography was used. This allows to characterize damage in materials and to obtain a 3D viewing. The main objective of this thesis was to study damage (nucleation, growth and coalescence) in composite materials using X-ray tomography during tensile tests. Selected materials are constituted of an aluminum matrix and small metallic glass reinforcements (Zr57Cu20Al_10Ni8Ti5). Composites with different volume fractions (from 1vol.% to 10vol.%) were prepared by Spark Plasma Sintering (SPS) and hot extrusion. A particular attention was paid to the microstructural characterization of the basic constituents. Qualitative analysis was used to compare SPS composites with SPS plus hot extrusion composites. Damage nucleation, growth and coalescence were observed. Quantitative analysis was mainly devoted to the first damage step. Growth and coalescence were difficult to follow due to fast rupture and interrupted tensile tests. The modeling of an amorphous-crystalline composite has been introduced in order to reproduce experimental damage analyses. The first approach requires further investigation to predict damage with different volume fractions. However, this part shows the beginning of an innovative model based on the experimental microstructure.

Page generated in 0.0728 seconds