• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 7
  • 1
  • 1
  • Tagged with
  • 40
  • 22
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

"Colonoscopia com magnificação de imagem: correlação das imagens endoscópicas com o diagnóstico histopatológico de pólipos e lesões planas" / Magnifying colonoscopy : correlation between endoscopic images with histopathologic diagnosis of polyps and flat lesions

Esdras Camargo Andrade Zanoni 17 January 2006 (has links)
A colonoscopia com magnificação de imagem (CMI), associada à cromoendoscopia, tem mostrado a possibilidade de se diferenciar lesões neoplásicas e não-neoplásicas. Duzentas e treze lesões colorretais foram magnificadas e analisadas, através da classificação de Kudo, por 3 observadores distintos e também comparadas com os resultados histopatológicos. Houve bom grau de concordância entre os observadores (Kappa = 0,561) para os diversos padrões de criptas. Não houve diferenças entre eles com relação à chance de acerto (p = 0,121; 0,500; 0,405). A acurácia do método foi de 84%, sensibilidade de 91,4%, especificidade de 67,2%, valores preditivos positivo e negativo de 86,6% e 79,3%, índice de Kappa de 0,61. Esses resultados mostram que a CMI não deve ser utilizada na definição de conduta frente a lesões polipóides / Magnifying colonoscopy (MC) associated with chromoendoscopy has showed the possibility of differentiating neoplastic from non-neoplastic lesions. Two hundred and thirteen lesions were magnifyied and analysed, according to Kudo's classification, by 3 observers and compared with histopathological results. There was a good agreement index among them (Kappa = 0.561) with respect to the aspects of the pits. No differences were found in relation to the possibility of being correct (p = 0.121; 0.500; 0.405). Accuracy of method was 84%, sensitivity of 91.4%, specificity of 67.2%, positive and negative predictive values of 86.6% and 79.3%; Kappa index of 0.61. These results show that MC must not be used to define what should be done with polypoid lesions
32

Evolução clínica e endoscópica na doença de Crohn após o transplante de células-tronco hematopoiéticas

QUADROS, Luiz Gustavo de. 14 December 2015 (has links)
Submitted by Irene Nascimento (irene.kessia@ufpe.br) on 2016-07-13T16:53:32Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) LUIZ GUSTAVO DE QUADROS TESE.pdf: 9881637 bytes, checksum: d6ffb41dcf9858105a4bb9088ff3fd0f (MD5) / Made available in DSpace on 2016-07-13T16:53:32Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) LUIZ GUSTAVO DE QUADROS TESE.pdf: 9881637 bytes, checksum: d6ffb41dcf9858105a4bb9088ff3fd0f (MD5) Previous issue date: 2015-12-14 / Introdução: Não existe atualmente uma terapia para tratamento de pacientes com Doença de Crohn refratária quando os tratamentos convencionais como antiinflamatórios, esteroides, imunossupressores e agentes biológicos anti-TNF alfa falham. Neste contexto o Transplante Autólogo de Células Tronco Hematopoiéticas (TACTH) pode ser uma alternativa. Objetivos: O objetivo do estudo foi determinar, após o TACTH, os resultados clinicos e endoscópicos e a toxicicidade imediata nos pacientes com Doença de Crohn (DC) refratários na primeira série brasileira de dez (10) casos realizados em uma única instituição. Casuística e Métodos: Foram estudados retrospectivamente dez pacientes com DC refratários submetidos ao TACTH. O critério de inclusão foi um Índice de Atividade da Doença de Crohn (CDAI) maior que 240, Índice Crônico de Gravidade Craig (CSI) maior que 17, Harvey Bradshaw indice maior que quatro, doença comprovada colonoscopicamente e não respondedores a, pelo menos, dois agentes biológicos anti TNF alfa. O tratamento foi feito com ciclofosfamida e timoglobulina, seguido de infusão de células-tronco de sangue periférico não manipuladas e não selecionados, colhidas por leucaférese após condicionamento com Ciclofosfamida. Avaliação do TACTH durante o período de mobilização e condicionamento até os primeiros 30 dias após o procedimento foi feita utilizando os Critérios NCI Common Toxicity Criteria Questionnaire, CDAI e questionário de qualidade de vida (QV) Short Form 36. Avaliação por colonoscopia foi realizada utilizando como parâmetros as classificações de Rutgeerts, Índice de Gravidade Endoscópica da Doença de Chron (CDEIS) e escore endoscópico simples para Crohn (SES-CD), seis meses após o procedimento em sete pacientes. Resultados: A análise foi disponíveis para 10 pacientes (6 femininos e 4 masculinos), a idade média foi de 34 ± 8 anos (24-50), com CDAI no momento do transplante com mediana 311,6 (240 - 450,2), doença grave em quatro (57 , 1%) e três (42,9%) com doença moderada. Classificação Montreal, Idade: A1 28,6%, A2 57,1% e A3 14,3%; principais manifestações extraintestinais doenças autoimunes associadas: 42,9% B1, B2 42,9% e B1P: 14,3%; distúrbio gastrointestinal locais: L1: 14,3%, L3: 71,4%, L4: 14: 3. Apenas a toxicidade hematológica foi observada em todos os pacientes nas fases de mobilização e condicionamento: leucopenia, granulocitopenia, linfocitopenia, trombocitopenia e hipotensão em um paciente. Como toxicidade gastrointestinal, foi comum o surgimento de náuseas durante alguns dias em todo o período de mobilização e condicionamento. Também foram encontrados febre sem infecção em dois pacientes, assim como farmacodermia e infecção fúngica após enxerto, diagnosticada por CT de tórax, em um mesmo paciente. Nos primeiros 30 dias, apenas um paciente parecia ter reativação de CMV mas não confirmada. Qualidade de vida foi melhor em todos os pacientes e, em três domínios, esta melhora foi estatisticamente significativa. Conclusão: O procedimento foi seguro, com baixa toxicidade hematológica e com impacto clínico no CDAI e na QV. / Introduction: Currently no therapy exists to treat refractory Crohn disease when the conventional treatments based in anti-inflammatory, steroids, immunosuppressant and/or a biologic anti-TNF-α failed. In this scenario, Autologous Hematopoietic Stem cell Transplantation (AHSCT) may be an alternative. Goals: The objective of study was to determine, after AHSCT, the clinic and endoscopy outcome, as well as the immediate toxicity of patients with refractory Crohn’s disease in the first Brazilian case series of ten (10) patients from a single institution. Patients and Methods: Were studied ten patients retrospectively. The inclusion criteria were Crohn Disease Activity Index (CDAI) greater than 240, Craig Chronic severity index (CSI) greater than 17, Harvey Bradshaw index greater than four, comproved active disease by endocolonoscopy and lack of response to at least two anti TNFα biologic agents. The treatment was done with Cyclophosphamide and Thymoglobulin followed by infusion of unmanipulated and unselected peripheral blood stem cells, obtained by leukapheresis after Cyclophosphamide conditioning. The evaluation the Autologous Hematopoietic Stem Cell Transplantation during mobilization and conditioning period until the first 30 days after the procedure was performed using the NCI Common Toxicity Criteria Questionnaire, Chronic Disease Activity Index (CDAI) and Quality of Live (QoL) Short Form 3 questionnaire and Clinical Outcome Parameters. The evaluation by colonoscopy was dose through parameters Rutgeerts, Crohn’s Disease Endoscopic Index of Severity and Simple Endoscopic Score for Crohn’s six months after the procedure in seven patients. Results: The analysis was available for 10 patients (6 female and 4 male), with median age was 34 ± 8 years (24-50), with median CDAI at time of Transplantation of 311,6 (240 - 450,2) severe disease in four (57,1%) and moderate disease in three (42,9%). Montreal classification, Age: A1 28,6%, A2 57,1% e A3 14,3%; major extra intestinal manifestations associated autoimmune disorders: B1 42,9%, B2 42,9% e B1p:14,3%; gastrointestinal local disorder: L1: 14,3%, L3: 71,4%, L4: 14:3. Only hematologic toxicity was observed in all patients in mobilization and conditioning phases. Leukopenia, granulocytopenia, lymphocytopenia, thrombocytopenia, and hypotension were found in one patient. Concerning gastrointestinal toxicity, nausea was a frequent complaint for several days throughout the period of mobilization and conditioning. Further side-effects were fever without infection in two patients, as well as pharmacodermy and fungal infection after graft, diagnosed by chest CT, in the same patient. In the first 30 days, only one patient appeared to have CMV reactivation but it was not confirmed. Quality of life was better in all patients and the improvement in three domains was statistically significant. Conclusion: The procedure was safe, with low hematologic the toxicity, and has a clinical impact on CDAI and on QoL.
33

Neoplasias colorretais: aspectos epidemiológicos, endoscópicos e anatomopatológicos - estudo de série de casos

Dias, Ana Paula Telles Pires 29 February 2008 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-18T12:19:11Z No. of bitstreams: 1 anapaulatellespiresdias.pdf: 1519258 bytes, checksum: 115fa6d893019191b30393d181c96383 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-10-25T12:07:25Z (GMT) No. of bitstreams: 1 anapaulatellespiresdias.pdf: 1519258 bytes, checksum: 115fa6d893019191b30393d181c96383 (MD5) / Made available in DSpace on 2016-10-25T12:07:26Z (GMT). No. of bitstreams: 1 anapaulatellespiresdias.pdf: 1519258 bytes, checksum: 115fa6d893019191b30393d181c96383 (MD5) Previous issue date: 2008-02-29 / O carcinoma colorretal (CCR) é a segunda neoplasia mais freqüente na população mundial. A alta incidência do CCR e a diferença nos resultados do tratamento desta neoplasia, de acordo com o estádio da doença, justificam os esforços para o rastreamento, prevenção e detecção precoce. Objetiva-se neste estudo descrever os aspectos: epidemiológicos, endoscópicos e anatomopatológicos das neoplasias colorretais em uma série de casos e avaliar o papel da colonoscopia na prevenção do CCR. Trata-se de estudo descritivo de série de casos atendida em centro especializado em endoscopia digestiva, no período de janeiro de 2002 a dezembro de 2006. Foram coletados dados sobre 1.962 colonoscopias realizadas em 1.491 indivíduos e, em 492 (33%) foram identificadas lesões polipóides. 408 indivíduos foram considerados para fins de análise. Na série de casos 70% dos indivíduos eram assintomáticos. A prevalência de neoplasias colorretais foi de 50% (60/120) em homens e de 42,4% em mulheres (122/288). As neoplasias foram detectadas em 138 dos 287 indivíduos (48%), com 50 anos ou mais, e a sua prevalência foi significantemente maior do que naqueles com menos de 50 anos (44/121) 36,3% (p=0,01). Verificou-se que 58,9% dos indivíduos com neoplasia e neoplasia avançada apresentavam história familiar positiva para câncer de mama, útero, ovário e/ou colorretal. Nos 408 indivíduos, foram realizadas 679 colonoscopias, com retirada de 959 lesões polipóides; destas, 463 (48,3%) eram neoplásicas, incluindo 13(1,35%) adenocarcinomas. Nas lesões menores que 5 mm, foi evidenciado displasia em 36% (346/959). No colon proximal, 21% (85/408) dos indivíduos apresentavam lesões neoplásicas e 2% (8/408), neoplasias avançadas, incluindo seis casos de adenocarcinoma sem qualquer evidência de lesão em colon distal. Dentre os 232 indivíduos que apresentavam lesões neoplásicas (benignas e ou avançadas), 130 (56%) apresentavam apenas lesões em colon proximal. Se o rastreamento fosse realizado apenas com a retossigmoidoscopia, a perda diagnóstica de lesões neoplásicas benignas seria de 76(62,3%) nas mulheres e 29(48,3%) nos homens. Em relação ao adenocarcinoma, a perda diagnóstica seria de 50% para ambos os sexos. Neoplasias colorretais são comuns em indivíduos assintomáticos. Sexo masculino, idade avançada e história familiar para câncer são fatores de risco para a detecção de lesões. A colonoscopia consiste em método eficaz de rastreamento para o CCR, a remoção de lesões neoplásicas colorretais interfere diretamente na história natural desta forma de câncer. / The colorectal carcinoma (CRC) is the second most frequent cancer in the world population. The high incidence of CRC and the difference in the results of the treatment of cancer, according to the stage of disease justify the efforts for screening, prevention and early detection. The objective of this study was to describe the epidemiological, endoscopic and pathological of polypoid lesions and colorectal cancers and assess the role of colonoscopy in preventing the CRC. This is a descriptive study of number of cases addressed in centre specializing in gastrointestinal endoscopy. In the period January 2002 to December 2006, colonoscopies were performed in 1962 and 1,491 individuals in 492 (33%) of these have been identified polypoid lesions; 408 individuals were considered for analysis. The data were included and analyzed in the Epi Info-2000. In a series of cases studied, 60% of the subjects were asymptomatic. The prevalence of colorectal cancers was 50% (60/120) in men and 42.4% in women (122/288). The cancers were detected on 138 of the 287 individuals (48%) with 50 years or more, and their prevalence was significantly higher than those with less than 50 years (44/121) 36.3% (p = 0.01). It was found that 58.9% of individuals with advanced cancer and cancer had positive family history for cancer of the breast, uterus, ovary, or colorectal. In 408 individuals, 679 colonoscopies were performed, with withdrawal of 959 polypoid lesions; these, 463 (48.3%) were neoplasms, included 13 adenocarcinomas. In lesions smaller than 5 mm, was shown dysplasia in 36% (346/959). In the proximal colon, 21% (85/408) of the subjects had neoplastic lesions in 2% (8 / 408), advanced malignancies, including six cases of adenocarcinoma without any evidence of damage in distal colon. The indication of colonoscopy only by the presence of lesions in the distal colon is controversial. Among the 232 individuals who had neoplastic lesions (benign, or advanced), 130 (56%) had only injuries in proximal colon. If the screening was done only with the retossigmoidoscopy, loss diagnosis of benign neoplastic lesions would be 76 (62.3%) in women and 29 (48.3%) in men. Regarding adenocarcinoma, the loss would be diagnostic of 50% for both sexes. Colorectal neoplasms are common even in asymptomatic subjects. Male, age and family history for cancer are risk factors for the detection of lesions. A colonoscopy is the most effective method of screening for the CRC, indicated for all individuals over 50 years old because, by identifying and removing neoplastic lesions, the colonoscopist have the ability to interfere directly in the natural history of this form of cancer.
34

Sedação em colonoscopia: utilização do propofol em estudo comparativo entre três diferentes modos de administração / Sedation in colonoscopy: use of propofol in a comparative study of three different administration methods

Carvalho, Paulo Henrique Boaventura de 24 September 2015 (has links)
O uso do propofol em sedação para colonoscopia e outros procedimentos endoscópicos é cada vez mais frequente, devido ao seu rápido início de efeito e curto período de recuperação, com poucos efeitos residuais, o que o torna um anestésico ideal para o uso em condutas médicas realizadas em regime ambulatorial. Seu perfil farmacológico o posiciona como um anestésico adequado a métodos de administração endovenosa contínuos ou titulados, possibilitando maior controle na sua concentração plasmática. Devido à sua alta lipossolubilidade, o propofol difunde-se rapidamente ao sistema nervoso e outros tecidos aonde exercerá seu efeito clínico, intimamente ligado à propofolemia, com diminuição da atividade do sistema nervoso central, que determinará tanto a sedação nos seus diversos níveis, quanto os indesejados efeitos depressores do sistema cardiovascular e respiratório, podendo levar a uma diminuição importante do débito cardíaco e pressão arterial e também a uma depressão central do sistema regulatório da respiração, que pode gerar apneia ou hipoventilação significativas. O presente estudo teve como objetivo avaliar clinicamente, e com dosagem sérica, o propofol em três esquemas diferentes de infusão endovenosa. Foram avaliados aleatoriamente 50 pacientes submetidos à colonoscopia nos Serviços de Endoscopia do Hospital Ana Costa (Santos - SP) e no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (São Paulo-SP). Os pacientes foram divididos em três grupos, conforme o esquema de sedação que foi utilizado. O Grupo 1 recebeu fentanil no início, uma dose inicial de propofol de um miligrama por quilo em um minuto na indução, posteriormente recebeu propofol em infusão intermitente de doses fracionadas de 30 mg (bolus) conforme necessidade clínica durante o exame. O Grupo 2 recebeu fentanil no início, uma dose inicial de propofol de 1 mg/kg em um minuto na indução, após essa, recebeu propofol contínuo em uma solução diluída a 0,2% em solução glicosada a 5%, em uma dose inicial de 1 gota/kg de peso do paciente, o que equivale a aproximadamente 100 ug/kg/min, controlada manualmente e alterada conforme a necessidade clínica do exame. O Grupo 3 recebeu fentanil no início do exame, e propofol com dose calculada e administrada por bomba eletrônica computadorizada (Diprifusor®) em esquema de infusão contínua alvo controlada, numa dose inicial de indução de 4 ug/mL administrada em um minuto, baixada a 2 ug/mL após a dose inicial completada, e alteradas para mais ou para menos conforme a necessidade clínica do exame. Os pacientes foram monitorizados com eletrocardiografia contínua, pressão arterial não invasiva medida de dois em dois minutos, oximetria de pulso, capnografia de aspiração lateral e índice bispectral (BIS). As dosagens séricas de propofol foram feitas em três amostras de sangue colhidas por paciente. A primeira amostra, cinco minutos após a indução, a segunda ao endoscopista alcançar o ceco durante o exame e a terceira a cinco minutos após a última dose de propofol administrada ou ao término da infusão contínua, no final do exame. Não houve diferença estatística significativa entre os Grupos em relação às características físicas pessoais dos pacientes como: sexo (p = 0,976), estado físico de acordo com a American Society of Anestesiology (ASA) (p = 0,945), idade (p = 0,896), peso (p = 0,340), altura (p = 0,947), índice de massa corpórea (IMC) (p = 0406), nos parâmetros clínicos observados como menor valor de índice BIS (p = 0,871) e o tempo para alcançá-lo (p = 0,052), tempo médio do exame (p = 0,123) e efeitos adversos observados como a queda da saturação de oxigênio abaixo de 90% (p = 0,054). Houve diferença estatisticamente significativa nas pressões arteriais iniciais dos Grupos 2 e 3, que foram ligeiramente elevadas em relação ao Grupo 1 a sistólica (p = 0,008), diastólica (p = 0,018) e média (p = 0,008), porém após a indução, a média das pressões arteriais sistólica (p = 0,440), diastólica (p = 0,960) e média (p = 0,815), e as menores pressões alcançadas não foram estatisticamente diferentes: sistólica (p = 0,656), diastólica (p = 0,783) e média (p = 0,993). Não houve diferença estatística em relação à frequência cardíaca inicial (p = 0,453), média após indução (p = 0,702), e menor frequência cardíaca alcançada (p = 0,788). Houve diferença entre o número de agitações médias entre os Grupos (p = 0,001), sendo maior no Grupo 1, porém este número foi relacionado ao esquema de administração do propofol no Grupo 1, que foi administrado após a indução quando o paciente apresentou algum grau de agitação que necessitou aprofundamento anestésico. Houve queda de saturação de oxigênio em seis pacientes (12%) da amostra avaliada, revertidas em tempo menor que cinco minutos com manobras de elevação da mandíbula do paciente ou utilização de cânula de Guedel para desobstrução das vias aéreas. Antes das quedas na saturação de oxigênio, foram percebidas alterações típicas de obstrução de vias aéreas, hipopneia ou apneia nas ondas de capnografia em 16 pacientes (32%), sendo que, em alguns pacientes por mais de uma vez, demonstrando esse ser um bom parâmetro de monitorização para prevenir hipóxia, não houve diferença entre os Grupos no parâmetro de obstrução de vias aéreas/apneia (p = 0,543). Em relação à propofolemia, o comportamento médio dos pacientes dos três Grupos foi estatisticamente igual ao longo dos momentos de avaliação (p = 0,830), não havendo diferença média estatisticamente significativa entre os Grupos (p = 0,964). Não houve diferença entre o consumo do propofol médio por minuto de exame (p = 0,748). Em relação à análise de custos com a administração do propofol, o Grupo 1 apresentou o menor valor médio para as colonoscopias avaliadas com gasto médio de R$ 7,00, o Grupo 2 gastou em média R$ 17,50 e o Grupo 3 gastou em média R$ 112,70 com diferença estatisticamente significativa entre eles (p < 0,001). A conclusão é que os esquemas de administração do propofol testados foram seguros, e houve semelhança entre os Grupos nos parâmetros avaliados incluindo a propofolemia, porém com custos diferenciados entre eles. Em relação ao Grupo 1, devido ao maior número de agitações por minuto este pode ser um bom método para procedimentos mais curtos, para procedimentos mais longos os Grupos 2 e 3 se mostraram mais confortáveis para o responsável pela sedação / The use of propofol sedation for colonoscopies and other endoscopic procedures is increasing due to the rapid onset of effect and short recovery time with few residual effects, which makes it an ideal anesthetic for usingin outpatient medical procedures. Its pharmacological profile places it as a suitable anesthetic to continuous or titred intravenous administration, providing increased control in its plasma levels. Due to its high liposolubility, propofol diffuses rapidly to the central nervous system and other tissues where it shall perform its clinical effects, closely related to plasma concentration, and providing sedation at different levels, as much as the unwanted depressant effects of the cardiovascular and respiratory system, it may lead to a significant reduction in cardiac output and blood pressure and also a central regulatory breathing system depression, that can result in significant apnea or hypoventilation. This study aimed to evaluate clinically and serum, propofol in three different regimens of intravenous infusion. 50 patients submitted to colonoscopy in the endoscopy centers at Hospital Ana Costa (Santos - SP), and Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (São Paulo-SP), have been randomly assessed. Such patients were divided into three groups, according to the sedation scheme that was used for them. Group 1 received fentanyl at first, then a one milligram per kilogram propofol dose, at induction, in a minute, later they received intermittent infusion of propofol in fractionated doses of 30 mg (Bolus) according to clinical needs during the test. Group 2 received fentanyl in the beginning, a starting dose of propofol 1 mg/kg at induction in one minute, after that received propofol in a 0.2% solution diluted in 5% glucose solution at an initial 1 drop/kg of patient weight dose, equivalent to about one 100 u100/min, manually controlled and changed according to clinical need of the examination. Group 3 received in the beginning of the examination fentanyl and propofol calculated by target controlled continuous infusion electronic device (Diprifusor®), an initial loading dose of 4 ug/mL was administered in one minute, reduced at 2 ug/mL after the initial dose, changed up or down according to clinical needs of examination. Patients were monitorized with continuous electrocardiography, non-invasive blood pressure measured every two minutes, pulse oximetry, side suction capnography and bispectral index (BIS). Serum levels of propofol were performed on three samples of blood taken by each patient. The first sample, five minutes after the induction, the second when the endoscopist reached the cecum during the examination and the third sample five minutes after the last administered dose or the end of continuous infusion of propofol, at the end of the test. No statistically significant difference between groups with respect to personal physical characteristics of patients as: sex (p = 0.976), physical state according to the American Society of Anesthesiology (ASA) (p = 0.945), age (p = 0.896), weight (p = 0.340), height (p = 0.947), body mass index body (BMI) (p = 0.406) in clinical parameters observed as a minor reached bispectral index value (BIS) (p = 0.871) and time to reach it (p = 0.052), mean procedure time (p = 0.123) and adverse effects observed as a drop in oxygen saturation below 90% (p = 0.054). There was a difference between the number of averages agitations between groups (p = 0.001), being higher in Group 1, but that number was related to propofol administration scheme in Group 1, as this was administered after induction when the patient had some agitation that required deeper anesthesia. There was a statistically significant difference in initial blood pressures of groups 2 and 3, which were slightly higher compared to Group 1: systolic (p = 0.008), diastolic (p = 0.018) and mean (p=0.008), but after induction, the average systolic (p = 0.440), diastolic (p = 0.960) and average (p = 0.815), and lower pressures achieved: systolic (p = 0.656) and diastolic (p = 0.783) and average (p = 0.993), were not statistically different. There was no statistical difference from the initial heart rate (p = 0.453), average heart rate after induction (p=0.702), and lower heart rate achieved (p = 0.788). There was oxygen dessaturation below 90% in six patients (12%) of the study sample, reversed in less than five minutes with patient jaw thrust maneuver or use of Guedel cannula, for airway clearance. Before the declines in oxygen saturation, typical tract obstruction, hypopnea or apnea wave changes were noted in capnography in sixteen patients (32%), and in some patients for more than once, showing this to be a good monitoring parameter to prevent hypoxia in patients, there was no difference between Groups in the airway obstruction/apnea parameter (p = 0.543). Regarding serum propofol, the average behavior of patients in the three Groups were statistically similar over the time (p = 0.830), with no statistically significant mean difference between groups (p = 0.964). There was no difference between the average propofol consumption per minute examination (p = 0.748). Regarding cost analysis with the administration of propofol, Group 1 had the lowest average value for colonoscopies evaluated with an average expense of R$ 7.00, Group 2 spent on average R$ 17.50 and the Group spent 3 on average R$ 112.70 with a statistically significant difference (p < 0.001). The conclusion is that propofol administration schemes tested were safe and there was similarity between the Groups in the evaluated parameters including propofolemia, but with different costs among them. With respect to Group 1 due to the larger number of agitations per minute, this is a good method for shorter procedures, for longer procedures groups 2 and 3 were more comfortable for the person responsible for sedation
35

Comparação entre testes químico (o-toluidina) e imunoquímico de pesquisa de sangue oculto nas fezes e correlação com os achados colonoscópicos / Comparison between chemical (toluidine) and immunochemical faecal occult blood tests and correlation with the colonoscopic findings

Borges, Luana Vilarinho 24 April 2013 (has links)
Introdução: O sangramento colorretal é considerado um sinal de alarme e não deve ser ignorado. A perda de sangue pode não ser identificada pelo paciente, o que caracteriza a presença de sangue oculto. Este diagnóstico pode ser confirmado por testes de Pesquisa de Sangue Oculto nas Fezes (PSOF), através de métodos químicos ou imunoquímicos de identificação da hemoglobina. O resultado positivo de um teste de PSOF requer investigação complementar com colonoscopia, exame invasivo, de alto custo e que exige preparo intestinal. Justifica-se, portanto, a aplicação de um teste diagnóstico mais sensível e específico. No presente estudo, foram avaliados quatro diferentes testes de PSOF em 176 pacientes submetidos à colonoscopia e seus resultados foram comparados. Objetivos: 1) avaliar o grau de concordância entre os testes de PSOF e a colonoscopia. 2) avaliar a sensibilidade, a especificidade e os valores de predição dos testes químico e imunoquímico de PSOF, em pacientes submetidos à colonoscopia. Métodos: Pacientes com indicação de realizar colonoscopia foram submetidos também à PSOF pelo método químico (o-toluidina) e pelo método imunoquímico, empregando três kits comerciais disponíveis no mercado. Os pacientes foram avaliados quanto à indicação do exame colonoscópico, resultado da colonoscopia e uso de alimentos e medicamentos que pudessem interferir no resultado dos testes fecais. Fundamentado nos achados endoscópicos, a colonoscopia foi categorizada em positiva ou negativa, de acordo com a possível fonte de sangramento colorretal. O grau de concordância entre os testes de PSOF foi avaliado pelo índice Kappa. Resultados: Dos 176 pacientes, houve predomínio do sexo feminino (64,8%), com média de idade de 55,5 anos. As indicações clínicas mais frequentes para realização de colonoscopia foram alteração do hábito intestinal, doença inflamatória intestinal, dor abdominal e anemia. Os principais achados foram pólipos < 1 cm, doença diverticular não complicada do cólon e exame normal. Quarenta e quatro (25%) colonoscopias foram categorizadas como positivas quanto à fonte de sangramento colorretal. Observou-se concordância (p<0,05) entre todos os testes avaliados e a colonoscopia. O teste da o-toluidina apresentou concordância pobre (Kappa 0,03), enquanto os demais testes apresentaram concordância moderada (Kappa entre 0,43-0,48). O teste da o-toluidina revelou menor sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo em comparação aos testes imunoquímicos. Conclusões: Os testes imunoquímicos apresentaram melhores índices de concordância com a colonoscopia, quando comparados ao teste da o-toluidina. Os testes imunoquímicos revelaram maior sensibilidade, especificidade e valores de predição na detecção de sangramento colorretal / Introduction: Colorectal bleeding is considered an alarm sign and should not be ignored. Blood loss can not be identified by the patient, which characterizes the presence of occult blood. This diagnosis can be confirmed by Faecal Occult Blood Testing (FOBT), through chemical or immunochemical methods. The positive outcome of a test requires complementary research FOBT with colonoscopy, an examination of invasive, costly and requires bowel preparation. It is justifiable, therefore, the application of diagnostic tests with better sensitivity and specificity. In the present study, we evaluated four different tests of PSOF in 176 patients undergoing colonoscopy and their results were compared. Objectives: 1) evaluate the degree of concordance between the PSOF tests and colonoscopy 2) assess the sensitivity, the specificity and the prediction values of the chemical and immunochemical FOBTs, in patients undergoing colonoscopy. Methods: Patients with indication of perform colonoscopy were subjected also to FOBT by the chemical method (toluidine test) and by the immunochemical method employing three commercial kits available in the market. Patients were evaluated regarding the indication of the colonoscopic examination, colonoscopy result, and use of foods and drugs that could interfere in the results of the faecal tests. Based on the endoscopic findings, the colonoscopy was rated as positive or negative, according to the possible colorectal bleeding source. The degree of accordance between FOBTs was evaluated by the Kappa index. Results: Among the 176 patients, there was a predominance of female gender (64.8%) with an average age of 55.5 years old. The most frequent clinical indication for colonoscopy were bowel habit changes, inflammatory bowel disease, abdominal pain and anemia. The main findings of colonoscopy were polyps <1 cm, uncomplicated colonic diverticular disease and normal exam. Forty-four (25%) colonoscopies were categorized as positive as to the possible source of colorectal bleeding. There was agreement (p<0.05) between all tests evaluated and the colonoscopy. The toluidine test presented poor accordance (Kappa 0.03), while the others showed moderate concordance (Kappa 0.43-0.48). The toluidine test showed less sensitivity, specificity, positive predictive value and negative predictive value compared to immunochemical tests. Conclusions: Immunochemical tests showed the best indexes of agreement with colonoscopy, when compared to the toluidine test. The immunochemical tests have shown greater sensitivity, specificity and predictive values in detecting colorectal bleeding
36

Papel da colonoscopia com magnificação de imagem associada à cromoscopia no diagnóstico diferencial entre lesões neoplásicas e não-neoplásicas do intestino grosso / Course of neonatal bacterial meningitis according to birth weight

Coelho, José Celso Cunha Guerra Pinto 13 October 2005 (has links)
O Câncer colorretal (CCR) é um problema de saúde importante devido a sua incidência e mortalidade elevadas. O rastreamento e o diagnóstico precoce são a principal estratégia para diminuir a mortalidade pelo CCR. A colonoscopia convencional (CC), constitui o melhor método para o diagnóstico precoce do CCR e para o diagnóstico e tratamento das lesões precurssoras. Entretanto a CC apresenta taxas de falha de detecção não desprezíveis. A colonoscopia com magnificação de imagem (CM), vem sendo utilizada com o intuito de melhorar a performance da CC. A sua principal vantagem é a possibilidade de diferenciar lesões neoplásicas de não-neoplásicas, de maneira que apenas lesões neoplásicas seriam retiradas, diminuindo custos e riscos relacionados ao rastreamento por colonoscopia. O objetivo deste estudo é determinar a acurácia da CM para o diagnóstico diferencial entre lesões neoplásicas e não-neoplásicas do intestino grosso por meio da comparação entre o diagnóstico endoscópico e o fornecido pelo exame histopatológico convencional. Entre abril de 2002 e outubro de 2003, cento e vinte pacientes foram incluídos no estudo, tendo-se encontrado 200 lesões. Todas as lesões foram classificadas endoscopicamente através da CM com alta magnificação (até 200X), associada a cromoscopia com índigo carmim, de acordo com a classificação proposta por Kudo, e em seguida excisadas ou biopsiadas para estudo histopatológico. A acurácia da determinação do diagnóstico diferencial endoscópico em relação à histopatologia entre lesões neoplásicas e não-neoplásicas foi de 78,5%. A diferença da CM em relação ao exame histopatológico foi estatisticamente significativa (p<0,0001). Conclui-se que, no atual estágio de desenvolvimento, a CM, pela sua acurácia, não permite excluir o exame histopatológico para o diagnóstico diferencial entre as lesões neoplásicas e não-neoplásicas do intestino grosso. / Bacterial meningitis in the neonatal period is a severe disease, associated to elevated mortality and sequelae in around 12 to 29% of the survivors. Newborns whose birth weight is < 2,500g have a 3-fold increase in the risk of acquiring meningitis when compared to those whose weight is > or = 2,500; among those with very low birth weight (< 1,500g), the risk increases 17-fold. Objectives: General: to describe the clinical picture and the complications of bacterial meningitis in two groups of newborns, considered according to birth weight (< 2,500g or > or = 2,500g). Specific: to describe and compare the etiological agents, the frequency of neurological signs and symptoms and complications, mortality rate and duration of treatment in both groups. Methods: Observational study of 87 newborns with bacterial meningitis, admitted at the Neonatal Intensive Care Unit (NICU) of Instituto da Criança of Hospital das Clínicas of the University of São Paulo School of Medicine, during an 11-year period (January 1994 to December 2004). The data were obtained through the analysis of hospital files. Statistical analysis was carried out with Fisher\'s exact test and the non-parametric Mann Whitney test. Results: Bacteria were identified in the cerebrospinal fluid (CSF) of 39% of the patients, with 50% of them being Gram-positive and 50%, Gram-negative. Most neonates presented unspecific signs and symptoms: fever (63.2%), irritability (31%), and lethargy (26.4%). The neurological findings occurred in 35.3% of the cases. Complications occurred in 48.2% of the neonates, and were mainly seizures (23%), intracranial hemorrhage (14.9%) and hydrocephalus (13.8%) with a mortality rate of 11.5%. At the comparison between clinical evolution and birth weight, associations between weight > or = 2,500g and seizures (p=0.047), weight > or = 2,500g and concave fontanel (p=0.019), bacteria in the CSF and complications (p=0.008) and bacteria in the CSF and death (p=0.043) were observed. Conclusions: The etiological agents most often identified in the CSF were enterobacteria (41%), followed by B Streptococcus (17.5%), non-B Streptococcus (17.5%), Staphylococcus aureus (11.7%), Neisseria meningitidis (8.8%) and Enterococcus faecalis (3.0%), with no statistical difference between the type of bacteria and birth weight. The predominant signs and symptoms were unspecific, with neurological findings in 35% of the cases. The higher frequency of neurological signs and symptoms in newborns with birth weight > or = 2,500g suggest a higher degree of central nervous system maturity in these infants. Although the mortality was lower than that observed in previous studies at the same Service, the frequency of complications was high, regardless of birth weight. The presence of bacteria in the CSF was associated to a higher frequency of seizures and mortality. The need for prolonged treatment in newborns with low birth weight suggests higher disease severity in this group of neonates.
37

Comparação entre testes químico (o-toluidina) e imunoquímico de pesquisa de sangue oculto nas fezes e correlação com os achados colonoscópicos / Comparison between chemical (toluidine) and immunochemical faecal occult blood tests and correlation with the colonoscopic findings

Luana Vilarinho Borges 24 April 2013 (has links)
Introdução: O sangramento colorretal é considerado um sinal de alarme e não deve ser ignorado. A perda de sangue pode não ser identificada pelo paciente, o que caracteriza a presença de sangue oculto. Este diagnóstico pode ser confirmado por testes de Pesquisa de Sangue Oculto nas Fezes (PSOF), através de métodos químicos ou imunoquímicos de identificação da hemoglobina. O resultado positivo de um teste de PSOF requer investigação complementar com colonoscopia, exame invasivo, de alto custo e que exige preparo intestinal. Justifica-se, portanto, a aplicação de um teste diagnóstico mais sensível e específico. No presente estudo, foram avaliados quatro diferentes testes de PSOF em 176 pacientes submetidos à colonoscopia e seus resultados foram comparados. Objetivos: 1) avaliar o grau de concordância entre os testes de PSOF e a colonoscopia. 2) avaliar a sensibilidade, a especificidade e os valores de predição dos testes químico e imunoquímico de PSOF, em pacientes submetidos à colonoscopia. Métodos: Pacientes com indicação de realizar colonoscopia foram submetidos também à PSOF pelo método químico (o-toluidina) e pelo método imunoquímico, empregando três kits comerciais disponíveis no mercado. Os pacientes foram avaliados quanto à indicação do exame colonoscópico, resultado da colonoscopia e uso de alimentos e medicamentos que pudessem interferir no resultado dos testes fecais. Fundamentado nos achados endoscópicos, a colonoscopia foi categorizada em positiva ou negativa, de acordo com a possível fonte de sangramento colorretal. O grau de concordância entre os testes de PSOF foi avaliado pelo índice Kappa. Resultados: Dos 176 pacientes, houve predomínio do sexo feminino (64,8%), com média de idade de 55,5 anos. As indicações clínicas mais frequentes para realização de colonoscopia foram alteração do hábito intestinal, doença inflamatória intestinal, dor abdominal e anemia. Os principais achados foram pólipos < 1 cm, doença diverticular não complicada do cólon e exame normal. Quarenta e quatro (25%) colonoscopias foram categorizadas como positivas quanto à fonte de sangramento colorretal. Observou-se concordância (p<0,05) entre todos os testes avaliados e a colonoscopia. O teste da o-toluidina apresentou concordância pobre (Kappa 0,03), enquanto os demais testes apresentaram concordância moderada (Kappa entre 0,43-0,48). O teste da o-toluidina revelou menor sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo em comparação aos testes imunoquímicos. Conclusões: Os testes imunoquímicos apresentaram melhores índices de concordância com a colonoscopia, quando comparados ao teste da o-toluidina. Os testes imunoquímicos revelaram maior sensibilidade, especificidade e valores de predição na detecção de sangramento colorretal / Introduction: Colorectal bleeding is considered an alarm sign and should not be ignored. Blood loss can not be identified by the patient, which characterizes the presence of occult blood. This diagnosis can be confirmed by Faecal Occult Blood Testing (FOBT), through chemical or immunochemical methods. The positive outcome of a test requires complementary research FOBT with colonoscopy, an examination of invasive, costly and requires bowel preparation. It is justifiable, therefore, the application of diagnostic tests with better sensitivity and specificity. In the present study, we evaluated four different tests of PSOF in 176 patients undergoing colonoscopy and their results were compared. Objectives: 1) evaluate the degree of concordance between the PSOF tests and colonoscopy 2) assess the sensitivity, the specificity and the prediction values of the chemical and immunochemical FOBTs, in patients undergoing colonoscopy. Methods: Patients with indication of perform colonoscopy were subjected also to FOBT by the chemical method (toluidine test) and by the immunochemical method employing three commercial kits available in the market. Patients were evaluated regarding the indication of the colonoscopic examination, colonoscopy result, and use of foods and drugs that could interfere in the results of the faecal tests. Based on the endoscopic findings, the colonoscopy was rated as positive or negative, according to the possible colorectal bleeding source. The degree of accordance between FOBTs was evaluated by the Kappa index. Results: Among the 176 patients, there was a predominance of female gender (64.8%) with an average age of 55.5 years old. The most frequent clinical indication for colonoscopy were bowel habit changes, inflammatory bowel disease, abdominal pain and anemia. The main findings of colonoscopy were polyps <1 cm, uncomplicated colonic diverticular disease and normal exam. Forty-four (25%) colonoscopies were categorized as positive as to the possible source of colorectal bleeding. There was agreement (p<0.05) between all tests evaluated and the colonoscopy. The toluidine test presented poor accordance (Kappa 0.03), while the others showed moderate concordance (Kappa 0.43-0.48). The toluidine test showed less sensitivity, specificity, positive predictive value and negative predictive value compared to immunochemical tests. Conclusions: Immunochemical tests showed the best indexes of agreement with colonoscopy, when compared to the toluidine test. The immunochemical tests have shown greater sensitivity, specificity and predictive values in detecting colorectal bleeding
38

Papel da colonoscopia com magnificação de imagem associada à cromoscopia no diagnóstico diferencial entre lesões neoplásicas e não-neoplásicas do intestino grosso / Course of neonatal bacterial meningitis according to birth weight

José Celso Cunha Guerra Pinto Coelho 13 October 2005 (has links)
O Câncer colorretal (CCR) é um problema de saúde importante devido a sua incidência e mortalidade elevadas. O rastreamento e o diagnóstico precoce são a principal estratégia para diminuir a mortalidade pelo CCR. A colonoscopia convencional (CC), constitui o melhor método para o diagnóstico precoce do CCR e para o diagnóstico e tratamento das lesões precurssoras. Entretanto a CC apresenta taxas de falha de detecção não desprezíveis. A colonoscopia com magnificação de imagem (CM), vem sendo utilizada com o intuito de melhorar a performance da CC. A sua principal vantagem é a possibilidade de diferenciar lesões neoplásicas de não-neoplásicas, de maneira que apenas lesões neoplásicas seriam retiradas, diminuindo custos e riscos relacionados ao rastreamento por colonoscopia. O objetivo deste estudo é determinar a acurácia da CM para o diagnóstico diferencial entre lesões neoplásicas e não-neoplásicas do intestino grosso por meio da comparação entre o diagnóstico endoscópico e o fornecido pelo exame histopatológico convencional. Entre abril de 2002 e outubro de 2003, cento e vinte pacientes foram incluídos no estudo, tendo-se encontrado 200 lesões. Todas as lesões foram classificadas endoscopicamente através da CM com alta magnificação (até 200X), associada a cromoscopia com índigo carmim, de acordo com a classificação proposta por Kudo, e em seguida excisadas ou biopsiadas para estudo histopatológico. A acurácia da determinação do diagnóstico diferencial endoscópico em relação à histopatologia entre lesões neoplásicas e não-neoplásicas foi de 78,5%. A diferença da CM em relação ao exame histopatológico foi estatisticamente significativa (p<0,0001). Conclui-se que, no atual estágio de desenvolvimento, a CM, pela sua acurácia, não permite excluir o exame histopatológico para o diagnóstico diferencial entre as lesões neoplásicas e não-neoplásicas do intestino grosso. / Bacterial meningitis in the neonatal period is a severe disease, associated to elevated mortality and sequelae in around 12 to 29% of the survivors. Newborns whose birth weight is < 2,500g have a 3-fold increase in the risk of acquiring meningitis when compared to those whose weight is > or = 2,500; among those with very low birth weight (< 1,500g), the risk increases 17-fold. Objectives: General: to describe the clinical picture and the complications of bacterial meningitis in two groups of newborns, considered according to birth weight (< 2,500g or > or = 2,500g). Specific: to describe and compare the etiological agents, the frequency of neurological signs and symptoms and complications, mortality rate and duration of treatment in both groups. Methods: Observational study of 87 newborns with bacterial meningitis, admitted at the Neonatal Intensive Care Unit (NICU) of Instituto da Criança of Hospital das Clínicas of the University of São Paulo School of Medicine, during an 11-year period (January 1994 to December 2004). The data were obtained through the analysis of hospital files. Statistical analysis was carried out with Fisher\'s exact test and the non-parametric Mann Whitney test. Results: Bacteria were identified in the cerebrospinal fluid (CSF) of 39% of the patients, with 50% of them being Gram-positive and 50%, Gram-negative. Most neonates presented unspecific signs and symptoms: fever (63.2%), irritability (31%), and lethargy (26.4%). The neurological findings occurred in 35.3% of the cases. Complications occurred in 48.2% of the neonates, and were mainly seizures (23%), intracranial hemorrhage (14.9%) and hydrocephalus (13.8%) with a mortality rate of 11.5%. At the comparison between clinical evolution and birth weight, associations between weight > or = 2,500g and seizures (p=0.047), weight > or = 2,500g and concave fontanel (p=0.019), bacteria in the CSF and complications (p=0.008) and bacteria in the CSF and death (p=0.043) were observed. Conclusions: The etiological agents most often identified in the CSF were enterobacteria (41%), followed by B Streptococcus (17.5%), non-B Streptococcus (17.5%), Staphylococcus aureus (11.7%), Neisseria meningitidis (8.8%) and Enterococcus faecalis (3.0%), with no statistical difference between the type of bacteria and birth weight. The predominant signs and symptoms were unspecific, with neurological findings in 35% of the cases. The higher frequency of neurological signs and symptoms in newborns with birth weight > or = 2,500g suggest a higher degree of central nervous system maturity in these infants. Although the mortality was lower than that observed in previous studies at the same Service, the frequency of complications was high, regardless of birth weight. The presence of bacteria in the CSF was associated to a higher frequency of seizures and mortality. The need for prolonged treatment in newborns with low birth weight suggests higher disease severity in this group of neonates.
39

Sedação em colonoscopia: utilização do propofol em estudo comparativo entre três diferentes modos de administração / Sedation in colonoscopy: use of propofol in a comparative study of three different administration methods

Paulo Henrique Boaventura de Carvalho 24 September 2015 (has links)
O uso do propofol em sedação para colonoscopia e outros procedimentos endoscópicos é cada vez mais frequente, devido ao seu rápido início de efeito e curto período de recuperação, com poucos efeitos residuais, o que o torna um anestésico ideal para o uso em condutas médicas realizadas em regime ambulatorial. Seu perfil farmacológico o posiciona como um anestésico adequado a métodos de administração endovenosa contínuos ou titulados, possibilitando maior controle na sua concentração plasmática. Devido à sua alta lipossolubilidade, o propofol difunde-se rapidamente ao sistema nervoso e outros tecidos aonde exercerá seu efeito clínico, intimamente ligado à propofolemia, com diminuição da atividade do sistema nervoso central, que determinará tanto a sedação nos seus diversos níveis, quanto os indesejados efeitos depressores do sistema cardiovascular e respiratório, podendo levar a uma diminuição importante do débito cardíaco e pressão arterial e também a uma depressão central do sistema regulatório da respiração, que pode gerar apneia ou hipoventilação significativas. O presente estudo teve como objetivo avaliar clinicamente, e com dosagem sérica, o propofol em três esquemas diferentes de infusão endovenosa. Foram avaliados aleatoriamente 50 pacientes submetidos à colonoscopia nos Serviços de Endoscopia do Hospital Ana Costa (Santos - SP) e no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (São Paulo-SP). Os pacientes foram divididos em três grupos, conforme o esquema de sedação que foi utilizado. O Grupo 1 recebeu fentanil no início, uma dose inicial de propofol de um miligrama por quilo em um minuto na indução, posteriormente recebeu propofol em infusão intermitente de doses fracionadas de 30 mg (bolus) conforme necessidade clínica durante o exame. O Grupo 2 recebeu fentanil no início, uma dose inicial de propofol de 1 mg/kg em um minuto na indução, após essa, recebeu propofol contínuo em uma solução diluída a 0,2% em solução glicosada a 5%, em uma dose inicial de 1 gota/kg de peso do paciente, o que equivale a aproximadamente 100 ug/kg/min, controlada manualmente e alterada conforme a necessidade clínica do exame. O Grupo 3 recebeu fentanil no início do exame, e propofol com dose calculada e administrada por bomba eletrônica computadorizada (Diprifusor®) em esquema de infusão contínua alvo controlada, numa dose inicial de indução de 4 ug/mL administrada em um minuto, baixada a 2 ug/mL após a dose inicial completada, e alteradas para mais ou para menos conforme a necessidade clínica do exame. Os pacientes foram monitorizados com eletrocardiografia contínua, pressão arterial não invasiva medida de dois em dois minutos, oximetria de pulso, capnografia de aspiração lateral e índice bispectral (BIS). As dosagens séricas de propofol foram feitas em três amostras de sangue colhidas por paciente. A primeira amostra, cinco minutos após a indução, a segunda ao endoscopista alcançar o ceco durante o exame e a terceira a cinco minutos após a última dose de propofol administrada ou ao término da infusão contínua, no final do exame. Não houve diferença estatística significativa entre os Grupos em relação às características físicas pessoais dos pacientes como: sexo (p = 0,976), estado físico de acordo com a American Society of Anestesiology (ASA) (p = 0,945), idade (p = 0,896), peso (p = 0,340), altura (p = 0,947), índice de massa corpórea (IMC) (p = 0406), nos parâmetros clínicos observados como menor valor de índice BIS (p = 0,871) e o tempo para alcançá-lo (p = 0,052), tempo médio do exame (p = 0,123) e efeitos adversos observados como a queda da saturação de oxigênio abaixo de 90% (p = 0,054). Houve diferença estatisticamente significativa nas pressões arteriais iniciais dos Grupos 2 e 3, que foram ligeiramente elevadas em relação ao Grupo 1 a sistólica (p = 0,008), diastólica (p = 0,018) e média (p = 0,008), porém após a indução, a média das pressões arteriais sistólica (p = 0,440), diastólica (p = 0,960) e média (p = 0,815), e as menores pressões alcançadas não foram estatisticamente diferentes: sistólica (p = 0,656), diastólica (p = 0,783) e média (p = 0,993). Não houve diferença estatística em relação à frequência cardíaca inicial (p = 0,453), média após indução (p = 0,702), e menor frequência cardíaca alcançada (p = 0,788). Houve diferença entre o número de agitações médias entre os Grupos (p = 0,001), sendo maior no Grupo 1, porém este número foi relacionado ao esquema de administração do propofol no Grupo 1, que foi administrado após a indução quando o paciente apresentou algum grau de agitação que necessitou aprofundamento anestésico. Houve queda de saturação de oxigênio em seis pacientes (12%) da amostra avaliada, revertidas em tempo menor que cinco minutos com manobras de elevação da mandíbula do paciente ou utilização de cânula de Guedel para desobstrução das vias aéreas. Antes das quedas na saturação de oxigênio, foram percebidas alterações típicas de obstrução de vias aéreas, hipopneia ou apneia nas ondas de capnografia em 16 pacientes (32%), sendo que, em alguns pacientes por mais de uma vez, demonstrando esse ser um bom parâmetro de monitorização para prevenir hipóxia, não houve diferença entre os Grupos no parâmetro de obstrução de vias aéreas/apneia (p = 0,543). Em relação à propofolemia, o comportamento médio dos pacientes dos três Grupos foi estatisticamente igual ao longo dos momentos de avaliação (p = 0,830), não havendo diferença média estatisticamente significativa entre os Grupos (p = 0,964). Não houve diferença entre o consumo do propofol médio por minuto de exame (p = 0,748). Em relação à análise de custos com a administração do propofol, o Grupo 1 apresentou o menor valor médio para as colonoscopias avaliadas com gasto médio de R$ 7,00, o Grupo 2 gastou em média R$ 17,50 e o Grupo 3 gastou em média R$ 112,70 com diferença estatisticamente significativa entre eles (p < 0,001). A conclusão é que os esquemas de administração do propofol testados foram seguros, e houve semelhança entre os Grupos nos parâmetros avaliados incluindo a propofolemia, porém com custos diferenciados entre eles. Em relação ao Grupo 1, devido ao maior número de agitações por minuto este pode ser um bom método para procedimentos mais curtos, para procedimentos mais longos os Grupos 2 e 3 se mostraram mais confortáveis para o responsável pela sedação / The use of propofol sedation for colonoscopies and other endoscopic procedures is increasing due to the rapid onset of effect and short recovery time with few residual effects, which makes it an ideal anesthetic for usingin outpatient medical procedures. Its pharmacological profile places it as a suitable anesthetic to continuous or titred intravenous administration, providing increased control in its plasma levels. Due to its high liposolubility, propofol diffuses rapidly to the central nervous system and other tissues where it shall perform its clinical effects, closely related to plasma concentration, and providing sedation at different levels, as much as the unwanted depressant effects of the cardiovascular and respiratory system, it may lead to a significant reduction in cardiac output and blood pressure and also a central regulatory breathing system depression, that can result in significant apnea or hypoventilation. This study aimed to evaluate clinically and serum, propofol in three different regimens of intravenous infusion. 50 patients submitted to colonoscopy in the endoscopy centers at Hospital Ana Costa (Santos - SP), and Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (São Paulo-SP), have been randomly assessed. Such patients were divided into three groups, according to the sedation scheme that was used for them. Group 1 received fentanyl at first, then a one milligram per kilogram propofol dose, at induction, in a minute, later they received intermittent infusion of propofol in fractionated doses of 30 mg (Bolus) according to clinical needs during the test. Group 2 received fentanyl in the beginning, a starting dose of propofol 1 mg/kg at induction in one minute, after that received propofol in a 0.2% solution diluted in 5% glucose solution at an initial 1 drop/kg of patient weight dose, equivalent to about one 100 u100/min, manually controlled and changed according to clinical need of the examination. Group 3 received in the beginning of the examination fentanyl and propofol calculated by target controlled continuous infusion electronic device (Diprifusor®), an initial loading dose of 4 ug/mL was administered in one minute, reduced at 2 ug/mL after the initial dose, changed up or down according to clinical needs of examination. Patients were monitorized with continuous electrocardiography, non-invasive blood pressure measured every two minutes, pulse oximetry, side suction capnography and bispectral index (BIS). Serum levels of propofol were performed on three samples of blood taken by each patient. The first sample, five minutes after the induction, the second when the endoscopist reached the cecum during the examination and the third sample five minutes after the last administered dose or the end of continuous infusion of propofol, at the end of the test. No statistically significant difference between groups with respect to personal physical characteristics of patients as: sex (p = 0.976), physical state according to the American Society of Anesthesiology (ASA) (p = 0.945), age (p = 0.896), weight (p = 0.340), height (p = 0.947), body mass index body (BMI) (p = 0.406) in clinical parameters observed as a minor reached bispectral index value (BIS) (p = 0.871) and time to reach it (p = 0.052), mean procedure time (p = 0.123) and adverse effects observed as a drop in oxygen saturation below 90% (p = 0.054). There was a difference between the number of averages agitations between groups (p = 0.001), being higher in Group 1, but that number was related to propofol administration scheme in Group 1, as this was administered after induction when the patient had some agitation that required deeper anesthesia. There was a statistically significant difference in initial blood pressures of groups 2 and 3, which were slightly higher compared to Group 1: systolic (p = 0.008), diastolic (p = 0.018) and mean (p=0.008), but after induction, the average systolic (p = 0.440), diastolic (p = 0.960) and average (p = 0.815), and lower pressures achieved: systolic (p = 0.656) and diastolic (p = 0.783) and average (p = 0.993), were not statistically different. There was no statistical difference from the initial heart rate (p = 0.453), average heart rate after induction (p=0.702), and lower heart rate achieved (p = 0.788). There was oxygen dessaturation below 90% in six patients (12%) of the study sample, reversed in less than five minutes with patient jaw thrust maneuver or use of Guedel cannula, for airway clearance. Before the declines in oxygen saturation, typical tract obstruction, hypopnea or apnea wave changes were noted in capnography in sixteen patients (32%), and in some patients for more than once, showing this to be a good monitoring parameter to prevent hypoxia in patients, there was no difference between Groups in the airway obstruction/apnea parameter (p = 0.543). Regarding serum propofol, the average behavior of patients in the three Groups were statistically similar over the time (p = 0.830), with no statistically significant mean difference between groups (p = 0.964). There was no difference between the average propofol consumption per minute examination (p = 0.748). Regarding cost analysis with the administration of propofol, Group 1 had the lowest average value for colonoscopies evaluated with an average expense of R$ 7.00, Group 2 spent on average R$ 17.50 and the Group spent 3 on average R$ 112.70 with a statistically significant difference (p < 0.001). The conclusion is that propofol administration schemes tested were safe and there was similarity between the Groups in the evaluated parameters including propofolemia, but with different costs among them. With respect to Group 1 due to the larger number of agitations per minute, this is a good method for shorter procedures, for longer procedures groups 2 and 3 were more comfortable for the person responsible for sedation
40

[pt] AVALIAÇÃO DE AUMENTO DE DADOS VIA GERAÇÃO DE IMAGENS SINTÉTICAS PARA SEGMENTAÇÃO E DETECÇÃO DE PÓLIPOS EM IMAGENS DE COLONOSCOPIA UTILIZANDO APRENDIZADO DE MÁQUINA / [en] EVALUATION OF DATA AUGMENTATION THROUGH SYNTHETIC IMAGES GENERATION FOR SEGMENTATION AND DETECTION OF POLYPS IN COLONOSCOPY IMAGES USING MACHINE LEARNING

VICTOR DE ALMEIDA THOMAZ 17 August 2020 (has links)
[pt] O câncer de cólon é atualmente a segunda principal causa de morte por câncer no mundo. Nos últimos anos houve um aumento do interesse em pesquisas voltadas para o desenvolvimento de métodos automáticos para detecção de pólipos e os resultados mais relevantes foram alcançados por meio de técnicas de aprendizado profundo. No entanto, o desempenho destas abordagens está fortemente associado ao uso de grandes e variados conjuntos de dados. Amostras de imagens de colonoscopia estão disponíveis publicamente, porém a quantidade e a variação limitada podem ser insuficientes para um treinamento bem-sucedido. O trabalho de pesquisa desta tese propõe uma estratégia para aumentar a quantidade e variação de imagens de colonoscopia, melhorando os resultados de segmentação e detecção de pólipos. Diferentemente de outros trabalhos encontrados na literatura que fazem uso de abordagens tradicionais de aumento de dados (data augmentation) e da combinação de imagens de outras modalidades de exame, esta metodologia enfatiza a criação de novas amostras inserindo pólipos em imagens de colonoscopia publicamente disponíveis. A estratégia de inserção faz uso de pólipos gerados sinteticamente e também de pólipos reais, além de aplicar técnicas de processamento para preservar o aspecto realista das imagens, ao mesmo tempo em que cria automaticamente amostras mais diversas com seus rótulos apropriados para fins de treinamento. As redes neurais convolucionais treinadas com estes conjuntos de dados aprimorados apresentaram resultados promissores no contexto de segmentação e detecção. As melhorias obtidas indicam que a implementação de novos métodos para aprimoramento automático de amostras em conjuntos de imagens médicas tem potencial de afetar positivamente o treinamento de redes convolucionais. / [en] Nowadays colorectal cancer is the second-leading cause of cancer death worldwide. In recent years there has been an increase in interest in research aimed at the development of automatic methods for the detection of polyps and the most relevant results have been achieved through deep learning techniques. However, the performance of these approaches is strongly associated with the use of large and varied datasets. Samples of colonoscopy images are publicly available, but the amount and limited variation may be insufficient for successful training. Based on this observation, a new approach is described in this thesis with the objective of increasing the quantity and variation of colonoscopy images, improving the results of segmentation and detection of polyps. Unlike other works found in the literature that use traditional data augmentation approaches and the combination of images from other exam modalities, the proposed methodology emphasizes the creation of new samples by inserting polyps in publicly available colonoscopy images. The insertion strategy makes use of synthetically generated polyps as well as real polyps, in addition to applying processing techniques to preserve the realistic aspect of the images, while automatically creating more diverse samples with their appropriate labels for training purposes. Convolutional neural networks trained with these improved datasets have shown promising results in the context of segmentation and detection. The improvements obtained indicate that the implementation of new methods for the automatic improvement of samples in medical image datasets has the potential to positively affect the training of convolutional networks.

Page generated in 0.4288 seconds