• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 22
  • 22
  • 9
  • 8
  • 7
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da rotação ombro-quadril e co-contração muscular do tronco durante um movimento de rotação axial com manuseio de carga /

Monteiro, João André Bernini. January 2015 (has links)
Orientador: Tamotsu Hirata / Coorientador: Marcelo Sampaio Martins / Banca: José Elias Tomazini / Banca: Glauce Gonzaga Silva / Resumo: As dores lombares acometem 80% da população em geral. Os levantamentos manuais ocupacionais e a rotação axial do tronco estão amplamente relacionados às dores e lesões lombares. A Rotação Axial sozinha é a causa de 33% de todas as lesões na coluna vertebral, mas pouco é sabido sobre ela e o carregamento manual. O objetivo do presente estudo foi analisar a atividade de músculos específicos do tronco e a relação entre a rotação do ombro e do quadril durante a rotação axial. Nove voluntários do sexo masculino (idade: 22,4 ±1,06 anos; IMC: 20,79 ± 2,23 kg/m²; % gordura: 9 ± 3,84 %), sem prévia de dor lombar, participaram da pesquisa, realizando o movimento de Rotação axial com o carregamento de uma caixa. Utilizou-se a eletromiografia de superfície (EMG) para a captação dos sinais dos músculos oblíquo interno ipsilateral, oblíquo externo contralateral e dos eretores lombares direito e esquerdo, todos agonistas do movimento de rotação, e cinemetria 2D para a análise do comportamento do tronco ao longo da tarefa. Para o tratamento estatístico dos dados obtidos, o teste de variância simples, one-way ANOVA foi selecionado para as comparações (p<0,05). Os resultados da eletromiografia apresentaram um padrão muscular diferente apenas para o ângulo de 90° de Rotação axial, principalmente em relação à ativação muscular médio-lateral esquerda (p=0.001), co-ativação médio-lateral direita (p=0.004), atividade muscular individual do músculo eretor contralateral (p=0.001) e músculo oblíquo externo contralateral (p=0.01). Os achados da cinemetria sugerem que 90° de rotação é a posição de maior potencial lesivo, uma vez que foi encontrada uma maior diferença entre a rotação do quadril e do ombro para esse ponto de referência (p=0.001). Como conclusão, recomenda-se que sejam evitadas as angulações de 90° de Rotação Axial em tarefas de carregamento de carga / Abstract: Back pain affect 80% of the general population. The manual occupational lifting are widely related to lumbar disorders as well as axial rotation of the trunk. The axial rotation of the trunk alone is the cause of 33% of all spinal injuries, a fact that needs to be better understood, especially when it is performed together with the manual loading. The aim of this study was to analyze the activity of the erector and abdominal muscles, the load-carrying task agonists with asymmetry, and the relationship between the rotation of the shoulder and hip during axial rotation. Nine male volunteers (age: 22.4 ± 1.06 years; BMI: 20.79 ± 2.23 kg / m²;% fat: 9 ± 3.84%), without low back pain participated in the survey performing the motion of the axial rotation of the trunk with loading a box in four different conditions by varying the loaded weight and speed of execution during the task. We used surface electromyography (EMG) to capture the signs of the ipsilateral internal oblique muscle, contralateral external oblique and lumbar erector spine right and left and 2D kinematics for the analysis of trunk behavior along the axial rotation of the trunk with manual loading. The statistical treatment of the data obtained, the simple variance test, one-way ANOVA was selected for the comparisons (p <0.05). The results of the electromyography showed a different muscle pattern only for the angle of 90 ° axial rotation, especially in relation to medium-lateral muscle activation (p = 0.001), co-activation middle-right side (p = 0.004), activity individual muscle of the contralateral erector muscle (p = 0.001) and contralateral external oblique muscle (p = 0.01). The findings of the kinematics suggest that 90 ° of rotation is the most injury potential position since we found a larger difference between the hip and shoulder rotation to this reference point (p = 0.001) ... (Complete abstract click electronic access below) / Mestre
2

Efeito de diferentes ajustes do selim sobre o conforto e a cinemática angular da coluna lombar de ciclistas

Kleinpaul, Julio Francisco 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Desportos, Programa de Pós-Graduação em Educação Física, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T13:12:56Z (GMT). No. of bitstreams: 1 277216.pdf: 6212364 bytes, checksum: 5811e6905fdf4220d6ce7fd792b037fa (MD5) / Introdução: com base no que a literatura tem apresentado, o ajuste errôneo da bicicleta às características antropométricas do ciclista pode causar desconfortos e dores, o que pode ser um fator de risco para lesões, além de aumentar a possibilidade de abandono do esporte. Métodos quantitativos para a avaliação da coluna lombar têm interessado pesquisadores devido a frequência de associação entre desconforto no ciclismo e dor lombar. Em ciclistas recreacionais, os maiores erros no posicionamento são encontrados para a regulagem do selim, fator determinante para a postura da coluna lombar durante o ciclismo. Objetivo: analisar os efeitos de diferentes ajustes do selim sobre o conforto e o comportamento angular da coluna lombar. Métodos: Participaram deste estudo oito ciclistas recreacionais do sexo masculino (idade: 27 ± 6 anos; massa: 73,8 ± 6,8 kg; estatura: 1,77 ± 0,05 m). Antes de iniciarem as coletas de dados, os sujeitos foram esclarecidos sobre os objetivos da pesquisa, para então assinarem o Termo de Consentimento Livre e Esclarecido. Todas as avaliações foram realizadas nas dependências do Laboratório de Biomecânica do Centro de Desportos da Universidade Federal de Santa Catarina. A avaliação cinemática bidimensional foi feita com o software de análise postural (SAPO), sendo utilizadas duas câmeras, que operaram em frequência de 30 Hz. Um ciclossimulador, onde foi apoiada a bicicleta, foi utilizado para garantir um melhor equilíbrio aos ciclistas durante a avaliação. Todos os sujeitos pedalaram em uma bicicleta devidamente ajustada as características corporais de cada sujeito (com exceção da altura selim) para a aquisição de cinco ciclos de pedalada para as duas situações de ajuste do selim (avaliadas randomicamente), a taxa de produção de potência de 150 W, característica do ciclismo recreacional. Foram fixados marcadores reflexivos nas referências anatômicas (processos espinhosos da primeira à quinta vértebra lombar e primeira vértebra sacral, e espinhas ilíacas póstero- e ântero-superiores), que serviram para a determinação dos ângulos avaliados. Para levantar informações acerca do conforto foi aplicado um questionário após as coletas. Para a análise estatística foi aplicado Teste t de Student pareado para comparar o comportamento angular lombar durante o ciclo de pedalada nas duas posições. Os resultados de todas as análises foram considerados significativos quando p < 0,05. Resultados: em relação ao conforto, tanto geral quanto da coluna lombar, ocorreu diminuição do número de relatos de desconfortos após o ajuste correto da altura do selim. Em relação a amplitude angular dos segmentos lombares, pode-se perceber que na situação de selim ajustado ocorreram os maiores valores médios de flexão, inclinação e rotação, mas tanto na situação desajustada quanto ajustada, os valores fisiológicos não foram ultrapassados. Quanto ao comportamento ao longo do ciclo, pode-se perceber que a flexão teve um comportamento diferenciado, ou seja, ocorreram dois ciclos de flexão-extensão durante um ciclo completo do pé-de-vela (PDV) enquanto ocorreu apenas um ciclo de inclinação lateral ou de rotação neste mesmo período. A flexão apresentou, em média, na posição ajustada, os maiores valores no início e no meio do ciclo, e na posição desajustada, os maiores valores ocorreram no início e no fim do ciclo. Para a inclinação lateral e para a rotação os maiores valores foram encontrados respectivamente no Ponto Morto Inferior (PMI) e no Ponto Morto Superior (PMS), sendo que no PMI ocorreu a máxima inclinação e a máxima rotação para a direita e no PMS a máxima inclinação lateral e a máxima rotação para a esquerda em ambas as situações para todos os segmentos avaliados, demonstrando maior regularidade neste tipo de movimento. Conclusão: Por se tratar de um movimento cíclico, as maiores diferenças acorreram no início, meio e fim do mesmo, confirmando a oposição de fases que ocorre ao longo de um ciclo de PDV. Ocorreu diminuição do relato de desconforto após o ajuste, indicando a importância deste.
3

A influencia do calçado de salto alto sobre a lordose lombar associada aos musculos lombares e gstrocnemio / The influence of high heel shoes on lumbar lordosis associated to the lumbar muscles and gastrocnemios

Casarin, Cezar Augusto Souza 03 April 2005 (has links)
Orientador: Paulo Henrique Ferreira Caria / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T14:11:06Z (GMT). No. of bitstreams: 1 Casarin_CezarAugustoSouza_M.pdf: 406484 bytes, checksum: 9c5e962f1f2458381ce5e607bc1431ef (MD5) Previous issue date: 2005 / Resumo: Nas últimas décadas as mulheres vêm conquistando posições de destaque na sociedade ocidental o que exigiu novos cuidados com a aparência e os calçados de salto alto se tornaram um dos símbolos da feminilidade contemporânea. Discrepâncias entre a literatura popular e a científica a respeito da influencia do uso de calçados de salto alto no aumento da lordose lombar, bem como a atividade dos músculos lombares e gastrocnêmio durante o uso desses calçados, suscitaram essa pesquisa. A qual teve como objetivo analisar o ângulo da curvatura lombar da coluna vertebral, por meio de imagens digitais (ICC = 0.96), através do programa ALCIMAGEM e investigar a atividade eletromiográfica dos músculos longuíssimo dorsal e íliocostal lombar (eretores da espinha) e do músculo gastrocnêmio, bilateralmente. Foram avaliadas vinte e quatro voluntárias descalças e calçando sapatos com saltos de 1 cm, 5 cm e 10 cm de altura, de diferentes modelos, divididas em grupo (1) usavam sapatos de salto alto diariamente e grupo (2) não usavam sapatos de salto alto diariamente. Os valores em graus foram submetidos à análise de variância ANOV A e ao teste de TUKEY. Os dados eletromiográficos foram submetidos ao teste de FRIEDMAN e ao teste de MANN-WHITNEY. Os resultados apresentaram a ocorrência da retificação da lordose lombar, não havendo diferenças estatisticamente significativas entre os grupos (p>0,05). O maior ângulo de retificação lombar e a maior atividade eletromiográfica dos músculos analisados foram alcançados com o salto fino de 10 cm de altura. O músculo gastrocnêmio mostrou-se mais ativo eletromiograficamente e o grupo (1) apresentou maior atividade eletromiográfica que o (2). Conclui-se que o uso de calçados de salto alto não gera hiperlodose lombar, os músculos da perna foram mais ativos que os paravertebrais e que o grupo de mulheres que usa salto alto diariamente, apresentou maior atividade muscular dentre os músculos avaliados / Abstract: In the last deeades the women are oeeupying positions that previously were exclusively maseuline, what put them in prominenee position in the western soeiety. The largest exhibition raised larger eare with the appearanee and the high hell shoes are one of the symbols of the eontemporary femininity. The popular literature refers to the high heel shoes as eausers of the inerease of the lumbar lordosis, in eompensation the scientifie literature shows the reetifieation of that eurvature. Diserepancies also appeared in relation to the aetivity of the muscles spine ereetors and gastroenêmius, when if did use of high heel shoes. The present work had as objeetive analyzes the angle of the lumbar eurvature of the spine through digital images (ICC = 0.96) through the program ALCIMAGEM and to investigate the eleetromyographie aetivity of the muscles longuissimus dorsal and ilioeostalis lumbar (spine ereetors) as well as the portions lateral and medial of the muscle gastroenêmius, bilaterally. Were evaluate twenty four volunteers barefoot and putting on shoes with high heels of 1 em, 5 em and 10 em of height and of different models, divided in group (1) they used high heel shoes daily and group (2) they didn't use high heel shoes daily. The results presented the oeeurrenee of the reetifieation of the lumbar lordosis, not having differenees signifieants among the groups (p>0,05). The largest reaehed angle of lumbar reetifieation was with the shoe of fine high heels of 10 em of height. The muscle gastroenêmius was shown more eleetromyographie aetivate. The group (1) it presented higher eleetromyographie aetivity than group 2. Was eoncluded that the use of high heel shoes doesn't generate lumbar hiperlordosis, the muscles leg were more eleetromyographie aetive eompared to the low baek muscles and the women used high heel shoes daily it presented higher eleetromyographie activity / Mestrado / Biologia e Patologia Buco-Dental / Mestre em Anatomia
4

"Validação de testes de flexibilidade da coluna lombar" / VALIDATION OF LUMBAR SPINE FLEXIBILITY TESTS

Achour Júnior, Abdallah 22 March 2006 (has links)
Esta pesquisa teve como principal objetivo, validar o teste de flexibilidade da coluna lombar (Testprop), utilizando-se da radiografia como teste critério e o teste flexibilidade da coluna lombar de ADRICHEM e KORST (1973) para o sexo feminino e masculino. Participaram 19 mulheres (média de idade= 23,2 anos e desvio padrão= 1,3) e 18 homens (média de idade= 22,3 anos e desvio padrão= 1,4), universitários, saudáveis e ativos do Curso de Educação Física e Ciências do Esporte da Universidade Estadual de Londrina - PR. Inicialmente, verificou-se a fidedignidade e objetividade dos testes de flexibilidade da coluna lombar (Testprop e Testeips). O coeficiente de correlação intraclasse mostrou que o teste de flexibilidade Testprop apresenta fidedignidade elevada para o sexo feminino (R= 0,86) e elevada para o sexo masculino (R=0,85), e demonstrou haver objetividade moderada (R= 0,73) para o sexo feminino e elevada (R= 0,96) para o sexo masculino. Quanto ao teste de flexibilidade Testeips, a fidedignidade foi elevada (R= 0,85) e (R= 0,86) para o sexo feminino e masculino, respectivamente. A objetividade do teste de flexibilidade Testeips foi moderada (R= 0,62) para o sexo feminino e elevada para o sexo masculino (R= 0,91). Em relação à validade, o coeficiente de correlação de Pearson mostrou correlação baixa para o teste de flexibilidade Testprop (r= 0,11) para o sexo feminino e correlação moderada (r= 0,52) para o sexo masculino. No que diz respeito ao teste de flexibilidade Testeips, o coeficiente de correlação de Pearson foi baixo para o sexo feminino (r= 0,24) e moderado para o sexo masculino (r= 0,50). Concluiu-se que os testes de flexibilidade da coluna lombar Testprop e Testeips foram fidedignos e objetivos, mas não foram considerados válidos. / The main goal was to validate the flexibility test for the lumbar spine (Testprop), using x-ray as a criteria and the flexibility test of the lumbar spine designed by ADRICHEM and KORST (1973) for females and males, 19 women participated (mean age= 23,2 years old; standard deviation= 1,3 year old) and 18 men (mean= 22,3 year old and standard deviation = 1,4) healthy and active students from the Physical Education and Sport Science Course at the Universidade Estadual de Londrina-PR. Initially, it was verified reliability and objectivity (Testprop and Testeips) the lumbar spine flexibility. The intraclass correlation coefficient showed that the reliability of test of flexibility Testprop was high for woman (R= 0.86) and high for men (R= 0.85), there was a moderate objectivity (R= 0.73) for women and high (R= 0.96) for men. Concerning the flexibility test Testeips, the reliability was high (R= 0.85) and (R= 0.86) for woman and men, respectively. The objectivity for the flexibility test Testeips was moderate (R= 0.62) for women and high for men (R= 0.91). Concerning the validity, Pearson correlation coeficient demonstrated a low correlation for the flexibility test Testprop (r= 0.11) for women and moderate for men (r= 0.52). About the flexibility test, Testeips, Pearson correlation coefficient was low for woman (r= 0.24) and moderate for men (r= 0.50). It was concluded that the flexibility tests of the lumbar spine Testprop and Testeips were reliable and objective, but they were not considered valid.
5

Sistema de avaliação e tratamento da coluna lombar com o uso de tração mecânica /

Carvalho, André Sólon de. January 2015 (has links)
Orientador: Mauro Pedro Peres / Banca: José Geraldo Trani Brandão / Banca: Eliana Vieira Canettieri / Banca: Marcus Bruno Soares Forte / Banca: Silvio Silvério da Silva / Resumo: Segundo a Organização Mundial da Saúde (OMS), os distúrbios da coluna vertebral acometem cerca de 85% da população mundial em alguma fase de sua vida, sendo a segunda causa de incapacidade de trabalho na vida adulta. A hérnia de disco lombar é uma das doenças mais frequentes na prática clínica dos neurocirurgiões e ortopedistas, no entanto, o tratamento, ao contrário do que muitos pensam, é a princípio conservador, ou seja, a cirurgia é indicada somente em pacientes com sintomas refratários ao tratamento com fisioterapia e osteopatia, pois é comum o paciente não se recuperar rapidamente, e até 38% dos pacientes operados podem necessitar de novas cirurgias. A tração lombar é uma poderosa ferramenta para o reposicionamento articular e a liberação da compressão nervosa evitando assim, em um grande número de casos, uma intervenção cirúrgica. Neste trabalho foi desenvolvida uma maca capaz de realizar tração lombar mecanicamente monitorada, apresentando três novas metodologias para tratar e avaliar o uso da tração mecânica para a coluna lombar. A primeira, é a utilização de um eletroestimulador funcional (FES), para a correta colocação dos eletrodos de superfície do eletromiógrafo (EMG), fator este que minimiza o erro na coleta de dados. A segunda, é o posicionamento do paciente em decúbito ventral, que favorece a tração devido a anatomia da coluna lombar. A terceira é a tração dinâmica capaz de realizar a tração com movimento contínuo de flexo-extensão. Para avaliar a eficiência do sistema foram avaliados 10 (dez) voluntários, sendo descritos os dados de angulação, magnitude da força ou carga ideal aplicada, tempo e frequência da tração. Conclui-se neste estudo, um melhor aproveitamento dos benefícios da tração lombar e acreditando-se que os valores gerados servem como contribuição para auxílio do tratamento na protrusão e hérnia de disco da coluna lombar / Abstract: According to World Health Organization (WHO), disorders of the spine affect about 85% of world population at some stage in their life, being the second leading cause of work disability in adulthood. A herniated lumbar disc is one of the most common diseases in clinical practice by neurosurgeons and orthopedic surgeons, however, the treatment, contrary to what many believe is the conservative principle, surgery is indicated only in patients with symptoms refractory to treatment with physiotherapy and osteopathy, as is common for the patient does not recover quickly, and up to 38% of patients may need more surgery. The pull back is a powerful tool to reposition the joint and release of nerve compression, thus avoiding a large number of cases, surgery. For this it developed in this work a stretcher capable of performing lumbar traction, with three innovations: first, the use of an electro (FES) for the correct placement of electrodes surface electromyography (EMG) factor that minimizes the error in data collection. The second is the positioning of the patient in a supine position, a factor that favors the draw, because the anatomy of the lumbar spine. The third, dynamic traction, table has the ability to perform traction during flexion-extension movement. To assess the efficiency of the system were evaluated ten (10) volunteers, data angle, and magnitude of applied force or load ideal, time and frequency drift. The conclusion of this study was a better use of the benefits of lumbar traction and it is believed that the values generated serve as a scientific contribution to aid in the treatment of pathologies of the lumbar spine / Doutor
6

Análise da rotação ombro-quadril e co-contração muscular do tronco durante um movimento de rotação axial com manuseio de carga / Analysis of shoulder-hip rotation and muscle co-contraction of the trunk during an axial rotation movement with manual loading

Monteiro, João André Bernini [UNESP] 13 July 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-13. Added 1 bitstream(s) on 2015-12-10T14:28:22Z : No. of bitstreams: 1 000851968.pdf: 3073089 bytes, checksum: f47bb9622a3b74a1090bdfcf1d716edc (MD5) / As dores lombares acometem 80% da população em geral. Os levantamentos manuais ocupacionais e a rotação axial do tronco estão amplamente relacionados às dores e lesões lombares. A Rotação Axial sozinha é a causa de 33% de todas as lesões na coluna vertebral, mas pouco é sabido sobre ela e o carregamento manual. O objetivo do presente estudo foi analisar a atividade de músculos específicos do tronco e a relação entre a rotação do ombro e do quadril durante a rotação axial. Nove voluntários do sexo masculino (idade: 22,4 ±1,06 anos; IMC: 20,79 ± 2,23 kg/m²; % gordura: 9 ± 3,84 %), sem prévia de dor lombar, participaram da pesquisa, realizando o movimento de Rotação axial com o carregamento de uma caixa. Utilizou-se a eletromiografia de superfície (EMG) para a captação dos sinais dos músculos oblíquo interno ipsilateral, oblíquo externo contralateral e dos eretores lombares direito e esquerdo, todos agonistas do movimento de rotação, e cinemetria 2D para a análise do comportamento do tronco ao longo da tarefa. Para o tratamento estatístico dos dados obtidos, o teste de variância simples, one-way ANOVA foi selecionado para as comparações (p<0,05). Os resultados da eletromiografia apresentaram um padrão muscular diferente apenas para o ângulo de 90° de Rotação axial, principalmente em relação à ativação muscular médio-lateral esquerda (p=0.001), co-ativação médio-lateral direita (p=0.004), atividade muscular individual do músculo eretor contralateral (p=0.001) e músculo oblíquo externo contralateral (p=0.01). Os achados da cinemetria sugerem que 90° de rotação é a posição de maior potencial lesivo, uma vez que foi encontrada uma maior diferença entre a rotação do quadril e do ombro para esse ponto de referência (p=0.001). Como conclusão, recomenda-se que sejam evitadas as angulações de 90° de Rotação Axial em tarefas de carregamento de carga / Back pain affect 80% of the general population. The manual occupational lifting are widely related to lumbar disorders as well as axial rotation of the trunk. The axial rotation of the trunk alone is the cause of 33% of all spinal injuries, a fact that needs to be better understood, especially when it is performed together with the manual loading. The aim of this study was to analyze the activity of the erector and abdominal muscles, the load-carrying task agonists with asymmetry, and the relationship between the rotation of the shoulder and hip during axial rotation. Nine male volunteers (age: 22.4 ± 1.06 years; BMI: 20.79 ± 2.23 kg / m²;% fat: 9 ± 3.84%), without low back pain participated in the survey performing the motion of the axial rotation of the trunk with loading a box in four different conditions by varying the loaded weight and speed of execution during the task. We used surface electromyography (EMG) to capture the signs of the ipsilateral internal oblique muscle, contralateral external oblique and lumbar erector spine right and left and 2D kinematics for the analysis of trunk behavior along the axial rotation of the trunk with manual loading. The statistical treatment of the data obtained, the simple variance test, one-way ANOVA was selected for the comparisons (p <0.05). The results of the electromyography showed a different muscle pattern only for the angle of 90 ° axial rotation, especially in relation to medium-lateral muscle activation (p = 0.001), co-activation middle-right side (p = 0.004), activity individual muscle of the contralateral erector muscle (p = 0.001) and contralateral external oblique muscle (p = 0.01). The findings of the kinematics suggest that 90 ° of rotation is the most injury potential position since we found a larger difference between the hip and shoulder rotation to this reference point (p = 0.001) ... (Complete abstract click electronic access below)
7

Sistema de avaliação e tratamento da coluna lombar com o uso de tração mecânica / System evaluation and treatment of the lumbar spine using mechanical traction

Carvalho, André Sólon de [UNESP] 05 February 2015 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-05Bitstream added on 2015-05-14T16:59:03Z : No. of bitstreams: 1 000825172.pdf: 1169211 bytes, checksum: 6ea62b494664f697da481d8884dc9fd8 (MD5) / Segundo a Organização Mundial da Saúde (OMS), os distúrbios da coluna vertebral acometem cerca de 85% da população mundial em alguma fase de sua vida, sendo a segunda causa de incapacidade de trabalho na vida adulta. A hérnia de disco lombar é uma das doenças mais frequentes na prática clínica dos neurocirurgiões e ortopedistas, no entanto, o tratamento, ao contrário do que muitos pensam, é a princípio conservador, ou seja, a cirurgia é indicada somente em pacientes com sintomas refratários ao tratamento com fisioterapia e osteopatia, pois é comum o paciente não se recuperar rapidamente, e até 38% dos pacientes operados podem necessitar de novas cirurgias. A tração lombar é uma poderosa ferramenta para o reposicionamento articular e a liberação da compressão nervosa evitando assim, em um grande número de casos, uma intervenção cirúrgica. Neste trabalho foi desenvolvida uma maca capaz de realizar tração lombar mecanicamente monitorada, apresentando três novas metodologias para tratar e avaliar o uso da tração mecânica para a coluna lombar. A primeira, é a utilização de um eletroestimulador funcional (FES), para a correta colocação dos eletrodos de superfície do eletromiógrafo (EMG), fator este que minimiza o erro na coleta de dados. A segunda, é o posicionamento do paciente em decúbito ventral, que favorece a tração devido a anatomia da coluna lombar. A terceira é a tração dinâmica capaz de realizar a tração com movimento contínuo de flexo-extensão. Para avaliar a eficiência do sistema foram avaliados 10 (dez) voluntários, sendo descritos os dados de angulação, magnitude da força ou carga ideal aplicada, tempo e frequência da tração. Conclui-se neste estudo, um melhor aproveitamento dos benefícios da tração lombar e acreditando-se que os valores gerados servem como contribuição para auxílio do tratamento na protrusão e hérnia de disco da coluna lombar / According to World Health Organization (WHO), disorders of the spine affect about 85% of world population at some stage in their life, being the second leading cause of work disability in adulthood. A herniated lumbar disc is one of the most common diseases in clinical practice by neurosurgeons and orthopedic surgeons, however, the treatment, contrary to what many believe is the conservative principle, surgery is indicated only in patients with symptoms refractory to treatment with physiotherapy and osteopathy, as is common for the patient does not recover quickly, and up to 38% of patients may need more surgery. The pull back is a powerful tool to reposition the joint and release of nerve compression, thus avoiding a large number of cases, surgery. For this it developed in this work a stretcher capable of performing lumbar traction, with three innovations: first, the use of an electro (FES) for the correct placement of electrodes surface electromyography (EMG) factor that minimizes the error in data collection. The second is the positioning of the patient in a supine position, a factor that favors the draw, because the anatomy of the lumbar spine. The third, dynamic traction, table has the ability to perform traction during flexion-extension movement. To assess the efficiency of the system were evaluated ten (10) volunteers, data angle, and magnitude of applied force or load ideal, time and frequency drift. The conclusion of this study was a better use of the benefits of lumbar traction and it is believed that the values generated serve as a scientific contribution to aid in the treatment of pathologies of the lumbar spine
8

Estudo com elementos finitos em vértebras lombares após subtração pedicular / Finite element analysis in lumbar vertebrae after pedicular subtraction

Oppermann, Marcelo 03 June 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016. / Submitted by Camila Duarte (camiladias@bce.unb.br) on 2016-07-22T16:15:47Z No. of bitstreams: 1 2016_MarceloOppermann.pdf: 20541680 bytes, checksum: c528aab668bc069a9c7807708813a05e (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-07-29T12:27:55Z (GMT) No. of bitstreams: 1 2016_MarceloOppermann.pdf: 20541680 bytes, checksum: c528aab668bc069a9c7807708813a05e (MD5) / Made available in DSpace on 2016-07-29T12:27:55Z (GMT). No. of bitstreams: 1 2016_MarceloOppermann.pdf: 20541680 bytes, checksum: c528aab668bc069a9c7807708813a05e (MD5) / Os Parafusos Pediculares (PP) estão entre os implantes mais utilizados na ortopedia/neurocirurgia. Este assemelha-se a um parafuso comum, mas com particularidades específicas para o local onde será implantado. Macroscopicamente o osso vertebral contém estruturas que determinam sua característica funcional e duas são mais importantes, na relação com os PP, o pedículo e o corpo vertebral. O pedículo, microscopicamente, é formado por um tecido ósseo mais rígido capaz de aguentar maior carga, já o corpo vertebral, diferentemente, contém uma estrutura mais frágil, e são denominados, respectivamente, de osso cortical e trabecular. Existem duas formas de avaliar a ação mecânica dos PP, através de estudos físicos e com Modelos de Elementos Finitos (MEF). Os MEF são cada vez mais utilizados na prática biomecânica, já que são facilmente modelados, sem necessidade de maquinário especial e muito menos, requerem comissão de ética para sua aprovação. Através da criação de uma malha, adiciona-se propriedades físicas que representem as características do parafuso e do osso, e simula-se cargas. Com isso, é possível avaliar o resultado, em termos de tensão, deslocamento e inferir falhas ao sistema. Aqui, se estudou 5 tipos de parafuso, que representassem a média dos implantes comercializáveis, com desenhos estruturais diferentes entre si. Estes foram inseridos em um cilindro com duas porções, representando o pedículo e o corpo vertebral e submetidos a tração (arrancamento), com uma força de 500N. O objetivo foi de avaliar a tensão nas interfaces osso-parafuso e deslocamento, em duas situações, uma com o modelo intacto, e outro com subtração da área cilíndrica, que representasse o pedículo. O modelo obedeceu o princípio de ser isotrópico e linear. O resultado, sob o prisma do deslocamento, mostrou que na média, os 5 parafusos tiveram uma perda de fixação da ordem de 47%, quando a porção pedicular foi removida e aplicada a carga. Ademais, no que tange a individualidade dos parafusos, houve uma diferença significativa entre os cinco tipos, variando de 21,9% até 92,2% no aumento do deslocamento, no modelo sem a região pedicular. Sob o ponto de vista tensão, nenhum parafuso, em ambos os cenários, obteve valores que alcançassem o ponto de tensão de escoamento do osso trabecular, ou ponto de ruptura definitiva. Aqui, mais uma vez, houve diferença significativa entre os 5 tipos de PP. Muitos PP obtiveram menor tensão quando da subtração pedicular. Este fato é explicado por ser o osso trabecular mais deformável (Módulo de Elasticidade menor), assim passível de gerar menor tensão para um mesmo deslocamento. Enfim, este trabalho conseguiu relatar que numa eventual necessidade de remoção dos pedículos vertebrais, os implantes existentes no mercado apresentam uma grande capacidade de falha, demonstrado por uma um aumento médio de quase 50% no deslocamento do PP, quando 500N de carga é aplicado sob forma de arrancamento. ________________________________________________________________________________________________ ABSTRACT / The pedicle screws (PS) are currently the most widely used implants in orthopedics / neurosurgery. They resemble a common bolt, but with specific characteristics to fit into the bone. Macroscopically vertebral bone contains structures that determine their functional feature, but two are most important in relation to the PS, the pedicle and vertebral body. The pedicle microscopically, is formed with a rigid bone tissue, capable of withstanding greater load. The vertebral body, in contrast, contains a more brittle structure. They are named cortical and trabecular bone, respectively. There are two ways to evaluate the mechanical action of the PS, through physical studies and finite element models (FEM). FEM are increasingly used in the biomechanics practice, since they are easily modeled, without the need for special machinery, neither requires ethics committee for approval. By creating a mesh, added with physical properties, that represent the characteristics of the screw and the bone, they can simulate the loads existing in the screw-bone interface. With this, it makes possible to evaluate the results in terms of stress, displacement and interpreted as failure. Here, we studied 5 types of PS, which represent the average of marketable implants with different structural designs. These were inserted into a cylinder with two portions, representing the pedicle and vertebral body and put them to traction (pullout), with a force of 500N in order to evaluate the stress and the strain at the bone-screw interfaces between two situations, one with the intact model, and another with subtraction of the cylindrical area, represented by the pedicle. The model followed the principle to be isotropic and linear. The result, in the light of displacement, showed that on average, the 5 screws have a loss of 47% in fixation, when the pedicle portion was removed. Beside, regarding the individuality of the screws there was a significant difference among the five kinds, ranging from 21,9% to 92,2% increase in displacement, with and without the pedicle region. From the point of view of stress, no screw, in both scenarios, obtained values that reached the yield stress point of the trabecular bone, or point of final break. Here again, there was a significant difference between the five types of PS. Many PS obtained a lower stress when the pedicle was subtracted, a fact that was explained being the trabecular bone more deformable (lower elastic modulus) and likely to generate lower stress for the same displacement. In the end, this work was succeeded to report that if needed, the removal of the vertebral pedicles, the nowadays implants have a large fault capacity, shown by an average increase of almost 50% in the PS displacement, when load of 500N is applied in the form of pullout.
9

Estudo da aplicação de força durante a técnica de mobilização póstero anterior central na coluna lombar /

Muta, Henrique Shimanuki. January 2006 (has links)
Orientador: José Geraldo Trani Brandão / Banca: Luiz Carlos de Queiroz Faenquil / Banca: Mauro Pedro Peres / Resumo: Na fisioterapia existem procedimentos que dependem da percepção manual do fisioterapeuta por estarem relacionados à aplicação de forças graduadas. Alguns estudos demonstraram que há uma grande dificuldade na percepção da força, ocorrendo grande variabilidade em sua aplicação. O objetivo deste estudo foi desenvolver um equipamento portátil para a medida de forças aplicadas por fisioterapeutas durante a realização da técnica de pressão póstero anterior central na coluna lombar e analisar alguns parâmetros envolvidos no método de mobilização articular. Houve variabilidade na forma de aplicação das cargas em diferentes aspectos. Dessa forma, podemos demonstrar com esses resultados, que a percepção manual do fisioterapeuta durante a realização da técnica de pressão póstero anterior central não foi tão precisa comparando os valores estimados com os valores das cargas aplicadas durante o intervalo de coleta. / Abstract: In Physical Therapy there are some procedures that depend on manual sensibility of physical therapist because that involves graded forces. Some studies have shown that there is a great difficulty in the perception of the force, occuring great variability on the application. The purpose of this study is to develop a portable device to measure the forces applied by physical therapists during the procedure of posteroanterior central pressure in the lumbar spine and to analyze some parameter involved in the method of articular mobilization. There was variability in application of the technique in many ways. Therefore, we can show with these results that the manual sensibility of the physical therapists during the application of the posteroanterior central pressure technique wasnþt accurate comparing the estimated values to the actual results obtained during the experiment interval of time. / Mestre
10

"Validação de testes de flexibilidade da coluna lombar" / VALIDATION OF LUMBAR SPINE FLEXIBILITY TESTS

Abdallah Achour Júnior 22 March 2006 (has links)
Esta pesquisa teve como principal objetivo, validar o teste de flexibilidade da coluna lombar (Testprop), utilizando-se da radiografia como teste critério e o teste flexibilidade da coluna lombar de ADRICHEM e KORST (1973) para o sexo feminino e masculino. Participaram 19 mulheres (média de idade= 23,2 anos e desvio padrão= 1,3) e 18 homens (média de idade= 22,3 anos e desvio padrão= 1,4), universitários, saudáveis e ativos do Curso de Educação Física e Ciências do Esporte da Universidade Estadual de Londrina - PR. Inicialmente, verificou-se a fidedignidade e objetividade dos testes de flexibilidade da coluna lombar (Testprop e Testeips). O coeficiente de correlação intraclasse mostrou que o teste de flexibilidade Testprop apresenta fidedignidade elevada para o sexo feminino (R= 0,86) e elevada para o sexo masculino (R=0,85), e demonstrou haver objetividade moderada (R= 0,73) para o sexo feminino e elevada (R= 0,96) para o sexo masculino. Quanto ao teste de flexibilidade Testeips, a fidedignidade foi elevada (R= 0,85) e (R= 0,86) para o sexo feminino e masculino, respectivamente. A objetividade do teste de flexibilidade Testeips foi moderada (R= 0,62) para o sexo feminino e elevada para o sexo masculino (R= 0,91). Em relação à validade, o coeficiente de correlação de Pearson mostrou correlação baixa para o teste de flexibilidade Testprop (r= 0,11) para o sexo feminino e correlação moderada (r= 0,52) para o sexo masculino. No que diz respeito ao teste de flexibilidade Testeips, o coeficiente de correlação de Pearson foi baixo para o sexo feminino (r= 0,24) e moderado para o sexo masculino (r= 0,50). Concluiu-se que os testes de flexibilidade da coluna lombar Testprop e Testeips foram fidedignos e objetivos, mas não foram considerados válidos. / The main goal was to validate the flexibility test for the lumbar spine (Testprop), using x-ray as a criteria and the flexibility test of the lumbar spine designed by ADRICHEM and KORST (1973) for females and males, 19 women participated (mean age= 23,2 years old; standard deviation= 1,3 year old) and 18 men (mean= 22,3 year old and standard deviation = 1,4) healthy and active students from the Physical Education and Sport Science Course at the Universidade Estadual de Londrina-PR. Initially, it was verified reliability and objectivity (Testprop and Testeips) the lumbar spine flexibility. The intraclass correlation coefficient showed that the reliability of test of flexibility Testprop was high for woman (R= 0.86) and high for men (R= 0.85), there was a moderate objectivity (R= 0.73) for women and high (R= 0.96) for men. Concerning the flexibility test Testeips, the reliability was high (R= 0.85) and (R= 0.86) for woman and men, respectively. The objectivity for the flexibility test Testeips was moderate (R= 0.62) for women and high for men (R= 0.91). Concerning the validity, Pearson correlation coeficient demonstrated a low correlation for the flexibility test Testprop (r= 0.11) for women and moderate for men (r= 0.52). About the flexibility test, Testeips, Pearson correlation coefficient was low for woman (r= 0.24) and moderate for men (r= 0.50). It was concluded that the flexibility tests of the lumbar spine Testprop and Testeips were reliable and objective, but they were not considered valid.

Page generated in 0.0638 seconds