• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 26
  • 9
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Água mineral na região metropolitana do Recife: riscos de contaminação nos aqüíferos

Cezar França Barreto, Julio 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:36:56Z (GMT). No. of bitstreams: 2 arquivo5688_1.pdf: 2994190 bytes, checksum: 71f7c3cc37d50e576d3e3efc3780b4c1 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A contaminação das águas subterrâneas, tema central dessa pesquisa, está intimamente correlacionada à falta de controle dos órgãos competentes e fiscalizadores, os quais não se fazem presente apenas no que se refere à parte construtiva e operacional dos poços tubulares construídos em muitos casos indiscriminadamente, como também no processo de fiscalização continuada. A presença do Nitrato (NO3) na área de pesquisa em locais de vulnerabilidade alta dos aqüíferos em áreas das Grandes Concentrações Urbanas observadas in situ diz respeito à presença dos Aqüíferos, Beberibe, Barreiras, e o Boa Viagem, esse último existente principalmente em áreas de poços com poucas profundidades (poços amazonas), utilizado pela população menos esclarecida, geralmente com baixo poder aquisitivo, exposta a doenças veiculadas através da água consumida. Na área de pesquisa, definida como Área II (área foco), mais precisamente na subárea A , onde está localizada uma grande concentração habitacional, duas empresas de água mineral estão presentes (Santa Clara e Lisboa), nos bairros de Dois Unidos e Linha do Tiro, respectivamente (zona norte do Recife-PE). Nela foram encontradas situações preocupantes relacionadas com o (1) Aqüífero Barreiras, em alguns pontos já com índices elevados de Nitrato (NO3), e o (2) Aqüífero Beberibe, localizado em maiores profundidades, porém já propiciando a indícios de riscos futuros. Os riscos de contaminação do Nitrato (NO3) se fazem presente em geral através de poços mal construídos, independente de sua profundidade, pois apesar da causa da contaminação estão geralmente associada a áreas superficiais, afetadas por cargas contaminantes, poços perfurados de forma errada podem levar a contaminação dos aqüíferos, através de isolamentos mal elaborados (cimentação), ou simplesmente pela falta de camadas impermeabilizantes entre os aqüíferos mais superiores e os aqüíferos localizados mais abaixo, ou ainda através de rupturas ou colapso no seu revestimento ou filtros. No que diz respeito à Gestão Ambiental das Águas Minerais, as perspectivas não são muito animadoras, pois a presença crescente a cada ano no mercado de um novo conceito de água potável, definida como Água Adiciona de Sais, está em ritmo acelerado, inclusive com a presença de um grande número de poços tubulares clandestinos, construídos muitos deles por empresas sem respeito a qualquer norma técnica, e perfurados sem qualquer tipo de fiscalização, contribuindo para aumentar a possibilidade de contaminação das águas subterrâneas, comprometendo a qualidade das águas minerais explotadas de forma legal. O presente estudo tem por pretensão proporcionar informações com relação às águas minerais e mananciais subterrâneos da Região Metropolitana do Recife particularmente no que se refere aos riscos de poluição e contaminações relacionados a elevados índices de Nitrato, procurando mostrar as autoridades setoriais os possíveis riscos de contaminações, registrados durante as visitas realizadas in situ , bem como durante os trabalhos técnicos- científicos realizados durante a última década
2

Comparação entre diferentes processos de degradação do antibiótico sulfametoxazol / Comparison between different processes for degradation of antibiotic sulfamethoxazole

Hussain, Sajjad 28 February 2014 (has links)
A ocorrência de produtos farmacêuticos e de cuidados pessoais no meio ambiente tem levado a preocupações sobre seu impacto ambiental e à saúde pública. O sulfametoxazol (SMX) é um fármaco que tem sido encontrado amplamente no ambiente. Neste estudo foi verificada a eficácia de vários processos, a saber eletroquímico, eletroquímico foto assistido, fotoquímico, Fenton e foto-Fenton, para a degradação de SMX em solução aquosa. A degradação eletroquímica e eletroquímica foto assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. Durante ambos os processos, efeitos de diferentes parâmetros foram analisados, como a natureza do eletrólito, a concentração de eletrólito suporte (NaCl) e a densidade de corrente aplicada. Os experimentos fotoquímicos, Fenton e foto-Fenton foram realizados em um reator de vidro cilíndrico de compartimento único. O efeito das concentrações inicias de Fe2+ e de H2O2 foram estudados para os processos Fenton e foto-Fenton. Similarmente, o efeito do pH inicial, a concentração inicial do SMX e a temperatura foram investigados para todos os processos. A variação da concentração de SMX foi determinada por cromatografia líquida de alta eficiência (CLAE) e a quantidade de matéria orgânica foi monitorada por análise de carbono orgânico total (COT). Os resultados obtidos indicaram que o SMX foi completamente degradado, porém, o COT foi apenas parcialmente removido em todos os processos. No período de tempo de ensaio estabelecido o aumento da densidade de corrente e da concentração de NaCl mais eficiente para a degradação e remoção de COT nos processos eletroquímicos. A quantidade de Fe2+ e H2O2 aumenta a eficiência do processo Fenton e foto-Fenton, e meio ácido foi favorável para todos os processos. O consumo de energia elétrica, baseado no parâmetro EEO (energia por ordem) mostrou que os processos eletroquímicos são energeticamente mais eficientes do que os fotoquímicos. As degradações acompanhadas por CLAE acoplado à espectrometria de massas, permitiu que vários intermediários fossem identificados, sendo então proposta uma sequência reacional para a degradação do SMX. O radical hidroxila e o cloro ativo atacam os anéis benzílico e isoxazólico, tendo sido demonstrado que os compostos iniciais formados foram os compostos hidrolisados e clorados. Os íons inorgânicos, tais como: NO3-, NH4+ e SO42-, também foram identificados durante os processos de degradação. / The occurrence of pharmaceuticals and personal care products in the environment has raised concerns about their impact upon environmental and public health. Sulfamethoxazole (SMX) is a pharmaceutical that has been found widely in the environment. This study investigated the effectiveness of various processes such as electrochemical, photo assisted electrochemical, photochemical, Fenton photo-Fenton to SMX degradation in aqueous solution. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. During both these processes the effects of different parameters were analyzed, such as, nature of the electrolyte concentration of the supporting electrolyte (NaCl) and the applied current density. The photochemical, Fenton and photo - Fenton experiments were carried out in a single compartment cylindrical glass reactor. The effects initial iron concentrations and H2O2 were studied for Fenton and photo-Fenton processes. Similarly the effect of initial pH, initial concentration of SMX and temperature were investigated for all processes. The variation of SMX concentration was determined by high performance liquid chromatography (HPLC) and the amount of organic matter was monitored by analysis of total organic carbon (TOC). The results indicated that SMX was completely degraded, but TOC was partially removed in all processes studied, during experimental period the increase of the current density and NaCl concentration enhanced the degradation and TOC removal in the electrochemical processes. The amount of iron and H2O2 increases the efficiency of Fenton and photo-Fenton processes and acidic media was favorable for all processes. The electrical energy consumption parameter based on EEO (energy per order) was also evaluated and it was observed that the electrochemical processes are more energetically efficient than the photochemical. The degradations followed by HPLC coupled with mass spectrometry, in which several intermediates were identified and proposed a reaction sequence for the degradation of SMX. The hydroxyl radical and active chlorine attack benzene and isoxazólico rings, and has been demonstrated that the initial compounds formed were hydrolyzed and chlorinated compounds. Inorganic ions such NO3-, NH4+ and SO42- were also identified during degradation processes.
3

Comparação entre diferentes processos de degradação do antibiótico sulfametoxazol / Comparison between different processes for degradation of antibiotic sulfamethoxazole

Sajjad Hussain 28 February 2014 (has links)
A ocorrência de produtos farmacêuticos e de cuidados pessoais no meio ambiente tem levado a preocupações sobre seu impacto ambiental e à saúde pública. O sulfametoxazol (SMX) é um fármaco que tem sido encontrado amplamente no ambiente. Neste estudo foi verificada a eficácia de vários processos, a saber eletroquímico, eletroquímico foto assistido, fotoquímico, Fenton e foto-Fenton, para a degradação de SMX em solução aquosa. A degradação eletroquímica e eletroquímica foto assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. Durante ambos os processos, efeitos de diferentes parâmetros foram analisados, como a natureza do eletrólito, a concentração de eletrólito suporte (NaCl) e a densidade de corrente aplicada. Os experimentos fotoquímicos, Fenton e foto-Fenton foram realizados em um reator de vidro cilíndrico de compartimento único. O efeito das concentrações inicias de Fe2+ e de H2O2 foram estudados para os processos Fenton e foto-Fenton. Similarmente, o efeito do pH inicial, a concentração inicial do SMX e a temperatura foram investigados para todos os processos. A variação da concentração de SMX foi determinada por cromatografia líquida de alta eficiência (CLAE) e a quantidade de matéria orgânica foi monitorada por análise de carbono orgânico total (COT). Os resultados obtidos indicaram que o SMX foi completamente degradado, porém, o COT foi apenas parcialmente removido em todos os processos. No período de tempo de ensaio estabelecido o aumento da densidade de corrente e da concentração de NaCl mais eficiente para a degradação e remoção de COT nos processos eletroquímicos. A quantidade de Fe2+ e H2O2 aumenta a eficiência do processo Fenton e foto-Fenton, e meio ácido foi favorável para todos os processos. O consumo de energia elétrica, baseado no parâmetro EEO (energia por ordem) mostrou que os processos eletroquímicos são energeticamente mais eficientes do que os fotoquímicos. As degradações acompanhadas por CLAE acoplado à espectrometria de massas, permitiu que vários intermediários fossem identificados, sendo então proposta uma sequência reacional para a degradação do SMX. O radical hidroxila e o cloro ativo atacam os anéis benzílico e isoxazólico, tendo sido demonstrado que os compostos iniciais formados foram os compostos hidrolisados e clorados. Os íons inorgânicos, tais como: NO3-, NH4+ e SO42-, também foram identificados durante os processos de degradação. / The occurrence of pharmaceuticals and personal care products in the environment has raised concerns about their impact upon environmental and public health. Sulfamethoxazole (SMX) is a pharmaceutical that has been found widely in the environment. This study investigated the effectiveness of various processes such as electrochemical, photo assisted electrochemical, photochemical, Fenton photo-Fenton to SMX degradation in aqueous solution. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. During both these processes the effects of different parameters were analyzed, such as, nature of the electrolyte concentration of the supporting electrolyte (NaCl) and the applied current density. The photochemical, Fenton and photo - Fenton experiments were carried out in a single compartment cylindrical glass reactor. The effects initial iron concentrations and H2O2 were studied for Fenton and photo-Fenton processes. Similarly the effect of initial pH, initial concentration of SMX and temperature were investigated for all processes. The variation of SMX concentration was determined by high performance liquid chromatography (HPLC) and the amount of organic matter was monitored by analysis of total organic carbon (TOC). The results indicated that SMX was completely degraded, but TOC was partially removed in all processes studied, during experimental period the increase of the current density and NaCl concentration enhanced the degradation and TOC removal in the electrochemical processes. The amount of iron and H2O2 increases the efficiency of Fenton and photo-Fenton processes and acidic media was favorable for all processes. The electrical energy consumption parameter based on EEO (energy per order) was also evaluated and it was observed that the electrochemical processes are more energetically efficient than the photochemical. The degradations followed by HPLC coupled with mass spectrometry, in which several intermediates were identified and proposed a reaction sequence for the degradation of SMX. The hydroxyl radical and active chlorine attack benzene and isoxazólico rings, and has been demonstrated that the initial compounds formed were hydrolyzed and chlorinated compounds. Inorganic ions such NO3-, NH4+ and SO42- were also identified during degradation processes.
4

La acción contaminante en el razonamiento judicial de la protección al derecho a vivir en un medio ambiente libre de contaminación

Garrido Jiménez, Lorena January 2000 (has links)
Memoria (licenciado en ciencias jurídicas y sociales) / No autorizada por el autor para ser publicada a texto completo / La motivación de este trabajo radica en una personal preocupación por el medio ambiente, que si bien es creciente en el orden internacional, ha sido un ámbito de reciente dedicación en nuestro país, tanto por parte de los estudiosos, en particular los del derecho, como de quienes gobiernan, legislan y aquellos quienes finalmente deciden conflictos de relevancia jurídica. A mitad de este siglo, el medio ambiente comenzó a considerarse como un bien limitado, frágil y común a todos los seres humanos, ello como consecuencia de la reconstrucción física del mundo destruido por dos guerras mundiales, lo que produjo también un reajuste de la conducta humana que hasta el momento se había mostrado con un marcado carácter antropocéntrico en su relación con la naturaleza. Desde entonces comenzó a cimentarse una nueva visión más holística del medio ambiente, que se ha traducido en un nuevo orden ambiental y que se concreta jurídicamente en el hecho que las diversas naciones han incluido en sus respectivas constituciones la garantía de un entorno libre de contaminación. Puede sostenerse que caracteriza la protección al medio ambiente, además de su carácter holístico, el tratarse de una cuestión multidisciplinaria que, por las posibles implicancias ante un desaste en su equilibrio, sobrepasa nociones como soberanía o territorialidad, transformándose en una preocupación y un quehacer de carácter internacional.
5

Estudo numérico do transporte de metais pesados na área do lixão do município de Viçosa – MG / Numerical study of heavy metals transport in the dump area of the Viçosa city, Minas Gerais

Germano, Alex Magno 19 February 2001 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-07-13T12:28:54Z No. of bitstreams: 1 texto completo.PDF: 1700705 bytes, checksum: 4036faed76150b925980069ee8da7618 (MD5) / Made available in DSpace on 2017-07-13T12:28:54Z (GMT). No. of bitstreams: 1 texto completo.PDF: 1700705 bytes, checksum: 4036faed76150b925980069ee8da7618 (MD5) Previous issue date: 2001-02-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nos últimos anos, a disposição de resíduos sólidos urbanos em locais impróprios e sem qualquer controle ambiental tem despertado a atenção de diversos órgãos governamentais ambientais. O simples ato de se jogar lixo ao solo é capaz de gerar sérios danos ao meio ambiente, porque além de poluir o solo, estes resíduos podem vir a contaminar as águas superficiais e, até mesmo, as subterrâneas. A decomposição dos resíduos, associada à infiltração de águas pluviais, dá origem a um líquido de coloração escura, altamente poluidor, denominado chorume ou percolado, que infiltra no solo causando a sua contaminação. Segundo SANTOS (1996), acreditava-se que, no passado, os percolados do lixo eram completamente purificados pelo solo e, desta forma, não havia subterrâneas. a preocupação Atualmente, com porém, relação um à contaminação modo melhor de das águas quantificar a contaminação do percolado é através do estudo de transporte de massa em meios porosos, que leva em conta processos que envolvem mecanismos de advecção, dispersão, adsorsão, reações químicas, decaimento radioativo, entre outros. No presente trabalho, foi realizada uma análise numérica, utilizando o método dos elementos finitos, para avaliar o transporte de contaminantes e o nível de contaminação por metais pesados na área do Lixão do Município de Viçosa – MG. Foi executado, primeiramente, um levantamento plani-altimétrico da área do lixão e, em seguida, uma prospecção do terreno através de furos de sondagem à percussão. Amostras deformadas e indeformadas dos solos foram coletadas para ensaios de caracterização, permeabilidade e lixiviação. Pelos resultados alcançados no ensaio de lixiviação, foi possível traçar as curvas de eluição de metais pesados nos solos estudados e, através dessas, foram obtidos os parâmetros de transporte Rd e Dh. A partir destes dados, foi possível estimar, em um estudo de 100 anos, as plumas de contaminação de cada metal pesado. De uma maneira geral, entretanto, pode-se avaliar que a contaminação do lençol freático por metais pesados na região do lixão da cidade de Viçosa – MG, em função da disposição dos resíduos, é insignificante, uma vez que os contaminantes analisados só penetraram por um ou dois metros na camada superficial do solo. / In the last years, the disposal of municipal solid waste in inappropriate places and without any environmental control, has been a main concern of several environmental organisms. The simple act of discarding waste on the soil is capable of bringing serious damage to the environment. Besides polluting the soil, these wastes may also contaminate the groundwater. The wastes decomposition associated with precipitation infiltration generates a dark and highly pollutant liquid called leachate, that infiltrates into the soil causing its contamination. According to SANTOS (1996), it was believed, in the past, that the leachate was completely purified by the soil and, due to that, there was not a preocupation concerning the contamination of the groundwater. However, nowadays, it is possible to quantify the extent of leachate contamination through the study of mass transport in porous media which accounts for processes that involve advective, dispersion, sorption, chemical reactions, radioactive decline mechanisms, among others. In the present work, a numerical analysis was accomplished, using the finite element method, to evaluate the transport of pollutants and the level of contamination for heavy metals in the dump area of Viçosa city – MG. Initially, it was necessary to determine the topography of the region. Following, a few borings (SPT tests) and a test pit were made to establish, in a general matter, the stratification types of soil and the possible location of the groundwater table. Deformed and undeformed samples of the soils were collected for characterization, permeability and column testing. From the results obtained with the column testing, it was possible to trace the effluent breakthrough curves for heavy metals in the soils studied and, based on them, the transport parameters Rd and Dh were obtained. From these data, it was possible to estimate, in a 100 year simulation, the plumes of contamination of each heavy metal. In a general way, however, it was evaluated that the contamination of the water table, for heavy metals in the area of the dump of the Viçosa city – MG, as a consequence of the disposal of the wastes, is insignificant, once the pollutants analyzed only penetrated one or two meters the superficial layer of the soil.
6

Aplicação de técnicas electroquímicas na degradação de poluentes orgânicos aromáticos refratários

Neves Xavier, José Luis 20 September 2012 (has links)
Muchas de las actividades industriales existentes actualmente presentan el problema de los residuos generados y su gestión. Los residuos líquidos son una fuente importante de contaminación de los recursos hídricos, siendo necesario el control de las condiciones de su eliminación. Algunos parámetros están regulados por la legislación, nacional y estatal, sin embargo, incluso cumpliendo los requisitos de la legislación, este agua se elimina con concentraciones de contaminantes bajas. Algunos contaminantes orgánicos aromáticos presentan problemas de toxicidad y bioacumulación, incluso a bajas concentraciones. En general son un problema para el tratamiento biológico debido a su toxicidad (ya que son perjudiciales para los microorganismos depuradores de materia orgánica) y por su baja degradabilidad pueden pasar a través del tratamiento biológico sin descomponerse. Para los efluentes que contienen contaminantes orgánicos se han investigado ampliamente varios tratamientos alternativos, como el uso de los Procesos de Oxidación Avanzada - POA. Estos procesos están dirigidos a la degradación de los compuestos orgánicos, incluidos los refractarios, en un corto período de tiempo y con alta eficiencia. En este trabajo se investiga la aplicación del proceso de electrólisis - EL y fotoelectrooxidation - FEO a la degradación de contaminantes orgánicos aromáticos refractarios en soluciones sintéticas, para comprender mejor los fenómenos involucrados en el proceso de tratamiento de efluentes, así como su viabilidad técnica de aplicación. Otro punto estudiado fue el uso de la técnica de voltametría cíclica de barrido como una herramienta para evaluar el comportamiento electroquímico del material del ánodo y la definición de los parámetros de trabajo para investigar los procesos de oxidación evaluados. Ambos procesos de oxidación investigados han demostrado ser capaces de degradar compuestos orgánicos refractarios, y en el proceso de FEO se logró una mayor eficiencia de la degradación / Neves Xavier, JL. (2012). Aplicação de técnicas electroquímicas na degradação de poluentes orgânicos aromáticos refratários [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/17172 / Palancia
7

Degradação do antibiótico tetraciclina por vários processos em mistura salina / Degradation of antibiotic tetracycline by various processes in saline medium

Gul, Saima 25 April 2014 (has links)
A degradação de antibiótico tetraciclina (TeC) foi avaliada por vários processos a saber, eletroquímico, eletroquímico foto-assistido, Fenton e foto-Fenton. Uma vez que este tipo de antibiótico é excretado principalmente pelo sistema urinário, o meio selecionado foi uma mistura de sais predominantes na composição de urina, a qual apresenta alta concentração de diferentes íons, especialmente íons cloretos. As degradações eletroquímica e eletroquímica foto-assistida foram realizadas em uma célula de fluxo do tipo filtro-prensa, usando um ânodo dimensionalmente estável comercial com composição nominal Ti/Ru0,3Ti0,7O2. O decaimento da concentração do TeC foi determinado por cromatografia líquida de alta eficiência (CLAE) e a remoção da carga orgânica por análise de carbono orgânico total (COT). Os processos de degradação eletroquímica e eletroquímica foto-assistido utilizaram densidades de correntes de 20 a 40 mA cm-2 e concentração inicial de TeC de 200 mg L-1. Aplicando 30 mA cm-2, após duas horas a remoção de TeC foi de 91% e 98%, utilizando processo eletroquímico sem e com foto- assistência, respectivamente. A remoção de COT foi incompleta com um máximo de 17%. A fim de comparar o efeito da mistura salina sobre a degradação de TeC, as eletrólises também foram realizadas em NaCl 0,1 mol L-1, onde foi obtida degradação rápida e completa (100%) em ambos os processos, a remoção de COT também foi melhorada (~29%). A degradação de TeC obedeceu uma cinética de pseudo-primeira ordem. A degradação também foi avaliada utilizando os processos Fenton e foto-Fenton na mesma mistura salina variando a concentração inicial de H2O2 (50-150 mg L-1) e de Fe2+ (2,5-15 mg L-1). A concentração inicial de Fe2+ e H2O2 tem uma influência maior sobre a degradação durante ambos os processos. Durante o processo Fenton, sob condições otimizadas, a TeC foi degradada >96%, sendo 57% a redução de COT correspondente, enquanto em meio de NaCl ocorreu a remoção de 99% e redução de COT de 41%. Um ligeiro decaimento foi observado utilizando o processo foto-Fenton devido à influência de íons presentes no meio. Os intermediários de degradação também foram identificados por CLAE acoplado a espectrometria de massa durante os processos Fenton e foto-Fenton, sendo então proposta uma sequência reacional de degradação da TeC . / The degradation of antibiotics tetracycline (TeC) was evaluated by various processes such as electrochemical, photo-assisted electrochemical, Fenton and photo-Fenton. Since this type of antibiotic is excreted mainly by urinary system, the selected medium was a mixture of salts prevailing in composition of urine, which has high concentration of different ions, especially chloride ions. The electrochemical and photo-assisted electrochemical degradations were performed in a filter press type flow cell using a dimensionally stable anode with nominal composition of Ti/Ru0.3Ti0.7O2. The decrease in TeC concentration was analyzed by high performance liquid chromatography and total organic carbon analysis. The electrochemical and photo-assisted electrochemical degradation was performed at current densities of 20 to 40 mA cm-2 and initial TeC concentration of 200 mg L-1. At a current density of 30 mA cm-2,91% and 98% TeC was removed after 2 hours, during electrochemical and photo-assisted electrochemical processes respectively. The TOC removal was incomplete with maximum of 17%. In order to compare the TeC degradation in saline medium, electrolysis was also carried out in 0.1 mol L-1 NaCl, where fast and complete (100%) degradation was observed in both processes and TOC removal was also improved (~29 %). The degradation of TeC followed pseudo-first order kinetics. Fenton and Photo-Fenton process was also evaluated for the degradation of TeC in similar saline medium varying the initial concentration of H2O2 (50_150 mg L-1) and Fe2+ (2.5-15 mg L-1). The initial concentration of Fe2+ and H2O2 has a high influence upon TeC degradation during both processes. During Fenton process under optimized conditions, >96% of TeC was degraded and 57% TOC was removed. However in NaCl medium, 99% degradation 41% TOC was obtained. The degradation was slightly decreased during photo-Fenton process due to the influence of ions in the medium. The degradation Intermediates were also identified by HPLC coupled with mass spectrometer and proposed a reaction sequence for the degradation of TeC.
8

Avaliação da contaminação por aflatoxina M1 em leite cru e leite UHT / Evaluation of aflatoxin M1 contamination in raw milk and UHTmilk

Weigel, Michele January 2007 (has links)
A aflatoxina M1 (AFM1) é um metabólito tóxico resultante da biotransformação da aflatoxina B1 e pode ser secretada no leite de animais que ingerem alimentos contaminados com esta última. Considerando os efeitos adversos que podem ocorrer devido à ingestão do produto contaminado e visto que as crianças, maiores consumidoras deste alimento, são potencialmente mais sensíveis que os adultos aos efeitos desta micotoxina, a avaliação da presença de AFM1 no leite se faz necessária. Durante o período de março a novembro de 2006 foram analisadas 48 amostras de leite cru provenientes de 8 propriedades fornecedoras de leite para uma Cooperativa de Leite da Serra Gaúcha e 80 amostras de leite UHT, provenientes de 7 marcas distintas, comercializadas em Porto Alegre (RS). A metodologia empregada na análise de aflatoxina M1 envolveu partição líquido-líquido na etapa de extração, uso de coluna de sílica gel na etapa de purificação e Cromatografia em Camada Delgada para a detecção. O limite de detecção foi de 10 ng e a avaliação da eficiência do método apresentou valor de 86% no teste de recuperação. Nas condições de trabalho e pelo método utilizado nenhuma das amostras analisadas foi positiva para a presença de AFM1, sugerindo que as mesmas encontram-se dentro das conformidades legais. / Aflatoxin M1 (AFM1) is a toxic metabolite resulting of the biotransformation of aflatoxin B1, and may be sectreted in milk of animals that consume foods contaminated with aflatoxin B1. Considering the adverse effects that can occur when foods contaminated are consumed, and since children, the greatest milk consumer are potentially more susceptible than adults to the effects of this mycotoxin, the evaluation of the presence of AFM1 in milk is necessary. From March to November of 2006 48 samples of raw milk from 8 dairy farms that integrate a Milk Cooperative of mountain region of Rio Grande do Sul and 80 samples of UHT milk from 7 different brands commercialized in Porto Alegre were analized. The mehodology employed for the analysis of aflatoxin M1 involved liquid-liquid partition on the extraction step, use of silic gel column for the purification step and Thin Layer Chromatography for the detection. The evaluation of the method efficiency present a value of 86% in the recovery test and the detection level was 10ng. Following analysis conditions and the method employed none of the samples analyzed were positive for the presence of aflatoxin M1, suggesting that samples analysed attend the legal conformities.
9

Determinación de la Concentración Letal Media (CL50-96) y Efecto Histopatológico del Sulfato de Cobre Mediante Bioensayos con Alevinos del Carachi Amarillo (Orestias luteus)

Atencio Mamani, William Robert 22 October 2013 (has links)
La contaminación de los ambientes acuáticos conlleva a la afectación directa de las especies que se desarrollan en estos medios, tal es así que las especies endémicas son las que sufren más estos efectos en niveles aún no determinados, pero que definitivamente afectan su población y subsistencia. Esto motivó el presente trabajo de investigación, donde se tuvo como objetivo determinar la concentración letal media (CL50-96) y efecto histopatológico del sulfato de cobre en alevinos de Orestias luteus “carachi amarillo”. El trabajo se realizó en el Laboratorio de Acuicultura y el Laboratorio de Muestras Biológicas de la Dirección de Recursos Hidrobiológicos del Proyecto Especial Binacional Lago Titicaca (PELT), ubicado en Muelle Barco S/N, distrito de Chucuito, Puno y en el Laboratorio de Histopatología de la Facultad de Medicina de la Universidad Nacional del Altiplano, durante los meses de Abril a Noviembre del año 2010. Un total de 280 alevinos del Orestias luteus fueron expuestos a concentraciones de 20 µg/l; 10 µg/l; 5 µg/l; 2,5 µg/l; 1,25 µg/l y 0,63 µg/l de sulfato de cobre y un control durante un periodo de 96 horas. Se observó una mortalidad mínima de12 alevinos en la concentración de 0,63 µg/l de sulfato de cobre, mientras que el máximo de mortalidad fue 40 alevinos al final de las primeras 72 horas en las concentraciones de 20 µg/l y 10 µg/l de sulfato de cobre. La Concentración Letal Media (CL50-96) para el sulfato de cobre mediante el método Probit fue 1,65 µg/l al final de todo el experimento. Posteriormente y para determinar los efectos histopatológicos en los alevinos, estos fueron procesados, realizando cortes histológicos a diferentes niveles anatómicos y teñidos con la técnica de hematoxilina-eosina y conservados de manera permanente utilizando Bálsamo de Canadá. El sulfato de cobre afectó la estructura ocular, produciendo una atrofia celular del cristalino y el iris en la concentración de 20 µg/l, lo mismo en la estructura del iris a 10 µg/l en comparación al control.
10

Avaliação do cromo contido em resíduo sólido de laboratório e materiais solidificados e estabilizados para confecção de blocos. / Chromium evaluation of laboratory solid waste and stabilized materials for building blocks.

SILVA, Poliana Pinheiro da. 17 October 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-10-17T12:50:34Z No. of bitstreams: 1 POLIANA PINHEIRO DA SILVA - DISSERTAÇÃO - (PPGEQ) 2018.pdf: 2144616 bytes, checksum: 6e3ed48e5f78b19665929243895dd265 (MD5) / Made available in DSpace on 2018-10-17T12:50:34Z (GMT). No. of bitstreams: 1 POLIANA PINHEIRO DA SILVA - DISSERTAÇÃO - (PPGEQ) 2018.pdf: 2144616 bytes, checksum: 6e3ed48e5f78b19665929243895dd265 (MD5) Previous issue date: 2018-05-30 / Capes / Os resíduos gerados nas Universidades representam 1% do total de resíduo em relação à outras fontes geradoras de resíduo sólidos, porém apresentam dificuldade no tratamento devido a quantidade e diversidade de compostos presente em um único resíduo. Os resíduos são classificados de acordo com características de inflamabilidade, corrosividade, reatividade, toxicidade e patogenicidade (Classe I) ou biodegradabilidade, combustibilidade ou solubilidade em água (classe II A ou classe II B). Quando são classificados em perigosos causam danos à saúde e ao meio ambiente. Uma alternativa de tratamento é a estabilização por solidificação, que promove a incorporação dos resíduos a matrizes cimentícias. O objetivo principal deste trabalho foi realizar a avaliação do metal pesado Cromo contido nos Resíduos Sólidos de Laboratórios para possível uso em Blocos sem função estrutural. No procedimento experimental, foi adotado o planejamento no delineamento do tipo one-way com análise de regressão. A primeira etapa consistiu em determinar quanto foi liberado de cromo para o meio ambiente, a partir do teste de lixiviação; o resíduo sólido de laboratório bruto foi classificado em classe I. Para definir a melhor faixa de incorporação de resíduo foram confeccionados corpos de prova para realização de testes preliminares. Os corpos de prova foram confeccionados à base de cimento Portland pozolonico, areia fina, brita e resíduo sólido passivo do laboratório de engenharia química (RSL), os quais foram submetidos a ensaios de lixiviação para classificação dos mesmos. A partir destes foram definidas as porcentagens de 5, 20 e 35% RSL, e posteriormente realizado testes de integridade/ durabilidade e imobilização de contaminantes. Os melhores resultados de todas as análises, foram encontrados para a incorporação de 5% de resíduo sólido de laboratório. As matrizes com 5 e 20% passaram de classe I (perigosos) para classe IIB( não perigosos e inertes). A matriz com 35% foi aprovada no teste de integridade/durabilidade, mas reprovada no teste de lixiviação com 0,09mg/l de cromo total, valor 55,56% acima do limite máximo permissível. Os materiais tratados poderão ser usados na fabricação de blocos com função não estrutural após avaliação técnica do uso específico adotado na construção civil. / The residues generated in the universities represent 1% of the total waste in relation to other sources of solid waste, but they present difficulties in the treatment due to the quantity and diversity of compounds present in a single residue. Residues are classified according to flammability, corrosivity, reactivity, toxicity and pathogenicity (Class I) or biodegradability, combustibility or water solubility (Class II A or Class II B) characteristics. When classified as hazardous they cause damage to health and the environment. An alternative treatment is stabilization by solidification, which promotes the incorporation of the residues to cementitious matrices. The main objective of this work is to perform the evaluation of the heavy metal Chromium contained in the Solid Waste of Laboratories for use in Blocks without structural function. In the experimental procedure, the planning was adopted in the one-way type design with regression analysis.The first step consisted in determining how much was released from chromium to the environment, from the leaching test; the crude laboratory solid waste was classified in class I. To define the best range of residue incorporation, test specimens were prepared for preliminary tests.The test specimens were made with pozolonic Portland cement, fine sand, gravel and passive solid waste from the chemical engineering laboratory (RSL), which were submitted to leaching tests to classify them. From these, the percentages of 5, 20 and 35% RSL were defined, followed by integrity / durability tests and immobilization of contaminants.The best results of all the analyzes were found for incorporation of 5% (RSL). The matrices with 5 and 20% passed from class I to class IIB, the matrix with 35% was approved in the integrity / durability test, but failed in the leaching test with 0.09mg / l of chromium above the maximum limit.

Page generated in 0.1104 seconds