21

Desempenho de TMDS em edifícios submetidos a terremotos / Performance of TMD-equipped buildings subjecto to earthquake loading

Bosse, Rúbia Mara 03 March 2017 (has links)
Técnicas e dispositivos para controlar vibrações em estruturas vêm sendo desenvolvidos e aprimorados para garantir segurança a estruturas sujeitas a carregamentos dinâmicos de grande magnitude, como o caso de tufões e terremotos. Neste sentido, o controle passivo de vibrações por meio de amortecedores de massa sintonizados, TMDs (Tuned Mass Dampers), é utilizado com muita eficiência no controle de vibrações induzidas por carregamentos externos de baixas frequências, como ventos. Porém, terremotos possuem um amplo espectro de frequências e por isso não há um acordo sobre a eficácia dos TMDs ao mitigar vibrações induzidas por sismos. Neste trabalho, estudou-se a sensibilidade dos parâmetros de frequência de sintonização e razão de massa dos TMDs que influenciam seu desempenho para controlar vibrações em edifícios sob carregamentos de terremotos. Para isso utilizou-se um modelo mais preciso em elementos finitos de pórtico plano não linear geométricos para obtenção do comportamento estrutural de um edifício de 20 pavimentos. Na simulação dos terremotos, desenvolveu-se um código para geração de processos estocásticos totalmente não estacionários e espectro-compatíveis, simulados para três diferentes configurações de solo. Descobriu-se que TMDs sintonizados para altas frequências têm melhor desempenho na minimização de deslocamentos e frequências de oscilação da estrutura. Esta conclusão é contrastante com o que se encontra na literatura, de que dispositivos sintonizados para a primeira frequências natural da estrutura são mais eficientes. Também se observou que TMDs com altas razões de massa (i.e. maiores que 10%) têm melhor performance. O melhor desempenho dos TMDs foi observado em dispositivos com altas razões de massa e moderadas a altas frequências de sintonização. Este trabalho mostra que o desempenho de sistemas de controle de vibrações passivos como TMDs depende do tipo de solo, do projeto dos dispositivos, da correta avaliação da resposta estrutural e da adequada representação do fenômeno que excita a estrutura. / Techniques and devices for vibration control have been developed to ensure safety of structures subjected to relevant dinamic loads, as hurricanes and earthquakes. In this way, the passive control with TMDs (Tuned Mass Dampers) has been used with efficiency to suppress vibrations in structures subjected to low-frequency wind loads, for instance. However, for earthquakes that have a broad-banded frequency contend, there is no general agreement about the performance of TMDs. In this thesis, the sensitivity of TMD parameters that influence the performance of the devices is evaluated. An accutare non-linear plane frame finite element (FE) formulation is employed to estimate the structural behaviour of a 20-storey building under earthquake loads. For the representation of earthquakes, a code was developed for the generation of fully non-stationary spectrum-compatible stochastic process, for three types of soil. It was found that TMDs tuned to higher frequencies perform better at minimizing displacements and vibration frequencies, in contrast to what is commonly believed (e.g., that devices tuned to the building\'s fundamental natural frequency present ideal performance). Further, a compounding effect is also observed, with the best performance being obtained by TMDs of large mass tuned to moderate to high frequencies. The thesis shows that the performance of passive systems like TMDs depend on the type os soil, the design of the absorbers, the correct evaluation of structural behaviour and the right representation of the phenomenon that excitates the structure.
22

Análise dinâmica e controle de vibrações de passarelas de pedestres submetidas ao caminhar humano. / Dynamic analysis and vibration control of pedestrian footbridges subjected to human walking.

Joesley Pereira Mendes 29 May 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Passarelas de pedestres mistas (aço-concreto) e de aço são frequentemente submetidas a ações dinâmicas de magnitude variável, devido à travessia de pedestres sobre a laje de concreto. Estas ações dinâmicas podem produzir vibrações excessivas e dependendo de sua magnitude e intensidade, estes efeitos adversos podem comprometer a confiabilidade e a resposta do sistema estrutural e, também, podem levar a uma redução da expectativa de vida útil da passarela. Por outro lado, a experiência e o conhecimento dos engenheiros estruturais em conjunto com o uso de novos materiais e tecnologias construtivas têm produzido projetos de passarelas mistas (aço-concreto) bastante arrojados. Uma consequência direta desta tendência de projeto é um aumento considerável das vibrações estruturais. Com base neste cenário, esta dissertação visa investigar o comportamento dinâmico de três passarelas de pedestres mistas (aço-concreto) localizadas no Rio de Janeiro, submetidas ao caminhar humano. Estes sistemas estruturais são constituídos por uma estrutura principal de aço e laje em concreto e são destinados à travessia de pedestres. Deste modo, foram desenvolvidos modelos numérico-computacionais, adotando-se as técnicas tradicionais de refinamento presentes em simulações do método de elementos finitos, com base no uso do software ANSYS. Estes modelos numéricos permitiram uma completa avaliação dinâmica das passarelas investigadas, especialmente em termos de conforto humano. As respostas dinâmicas foram obtidas em termos de acelerações de pico e comparadas com valores limites propostas por diversos autores e normas de projeto. Os valores de aceleração de pico e aceleração rms encontrados na presente investigação indicaram que as passarelas analisadas apresentaram problemas relacionados com o conforto humano. Assim sendo, considerando-se que foi detectado que estas estruturas poderiam atingir níveis elevados de vibração que possam vir a comprometer o conforto dos usuários, foi verificado que uma estratégia para o controle estrutural era necessária, a fim de reduzir as vibrações excessivas nas passarelas. Finalmente, uma investigação foi realizada com base em alternativas de controle estrutural objetivando atenuar vibrações excessivas, a partir do emprego de sistemas de atenuadores dinâmicos sintonizados (ADS). / Steel and steel-concrete composite pedestrian footbridges are frequently subjected to dynamic actions with variable magnitudes due to the pedestrian crossing on the concrete deck. These dynamic actions can produce excessive vibrations and depending on their magnitude and intensity, these adverse effects can compromise the structural systems response and its reliability and may also lead to a reduction of the expected footbridge service life. The structural engineers experience and knowledge together with the use of newly developed materials and technologies have produced steel-concrete composite daring footbridges. A direct consequence of this design trend is a considerable increase of structural vibrations. Based on this scenario, this dissertation aims to investigate the dynamic behaviour of three steel-concrete composite pedestrian footbridge submitted to human walking vibration, located at Rio de Janeiro. These structural systems are composed by steel structure and a concrete slab and are destined for pedestrian crossing. Computational models were developed adopting the usual mesh refinement techniques present in finite element method simulations using ANSYS software. These numerical models have enabled a complete dynamic evaluation of the investigated footbridges especially in terms of human comfort and its associated vibration serviceability limit states. The dynamic responses were obtained in terms of peak accelerations and were compared to the limiting values proposed by authors and design standards. The peak acceleration values found in the present investigation indicated that the analysed footbridges have presented problems related to human comfort. Considering that it was detected that these structures could reach high vibration levels that might compromise the footbridge users comfort, it was proposed a structural control system in order to reduce the excessive vibrations. Thus, an investigation was performed based on some structural control alternatives for attenuating excessive vibrations using tuned mass damper (TMD) systems.
23

Análise dinâmica e controle de vibrações de pisos de edificações submetidos a atividades humanas rítmicas.

Cássio Marques Rodrigues Gaspar 05 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Um aumento crescente dos problemas estruturais associados à vibração excessiva de pisos de edificações de estruturas mistas (aço-concreto) e de concreto armado devido a atividades humanas rítmicas constitui a principal motivação para o desenvolvimento de uma metodologia de projeto respaldada na obtenção da resposta dinâmica de pisos mistos (aço-concreto) e de concreto armado, quando submetidos a cargas dinâmicas humanas rítmicas. Para tal, os modelos estruturais estudados baseiam-se em pisos de edificações mistas (aço-concreto) e de concreto armado submetidos a aulas de ginástica aeróbica. São empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Um estudo paramétrico foi realizado sobre os modelos estruturais investigados e foram obtidos valores elevados para as acelerações de pico violando os critérios de projeto e indicando níveis de vibrações excessivas. Considerando-se os aspectos mencionados anteriormente foi desenvolvida uma estratégia com base em alternativas viáveis para o controle estrutural, objetivando a atenuação das vibrações excessivas a partir da instalação de atenuadores dinâmicos sincronizados (ADS) nos pisos analisados. / The increasing incidence of building vibration problems due to human rhythmic activities led to a specific design criterion to be addressed in structural design. This was the main motivation for the development of a design methodology centred on the composite (steel-concrete) and reinforced concrete building floors dynamic response when submitted to dynamic loads due to human rhythmic activities. The structural system is composed by a composite (steel-concrete) and a reinforced concrete building floor subjected to aerobics. The proposed analysis methodology adopted the usual mesh refinement techniques present in the finite element method (FEM) simulations implemented in the ANSYS program. An extensive parametric study was developed and the results have demonstrated that the analysed composite and reinforced floor have presented high values of accelerations and excessive vibrations. Considering all aspects mentioned before, it was developed a structural control strategy aiming to reduce the floor excessive vibrations. Finally, an investigation was performed based on some structural control alternatives for attenuating excessive vibrations using Tuned Mass Damper (TMD) systems.
24

Análise dinâmica e controle de vibrações de passarelas de pedestres submetidas ao caminhar humano. / Dynamic analysis and vibration control of pedestrian footbridges subjected to human walking.

Joesley Pereira Mendes 29 May 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Passarelas de pedestres mistas (aço-concreto) e de aço são frequentemente submetidas a ações dinâmicas de magnitude variável, devido à travessia de pedestres sobre a laje de concreto. Estas ações dinâmicas podem produzir vibrações excessivas e dependendo de sua magnitude e intensidade, estes efeitos adversos podem comprometer a confiabilidade e a resposta do sistema estrutural e, também, podem levar a uma redução da expectativa de vida útil da passarela. Por outro lado, a experiência e o conhecimento dos engenheiros estruturais em conjunto com o uso de novos materiais e tecnologias construtivas têm produzido projetos de passarelas mistas (aço-concreto) bastante arrojados. Uma consequência direta desta tendência de projeto é um aumento considerável das vibrações estruturais. Com base neste cenário, esta dissertação visa investigar o comportamento dinâmico de três passarelas de pedestres mistas (aço-concreto) localizadas no Rio de Janeiro, submetidas ao caminhar humano. Estes sistemas estruturais são constituídos por uma estrutura principal de aço e laje em concreto e são destinados à travessia de pedestres. Deste modo, foram desenvolvidos modelos numérico-computacionais, adotando-se as técnicas tradicionais de refinamento presentes em simulações do método de elementos finitos, com base no uso do software ANSYS. Estes modelos numéricos permitiram uma completa avaliação dinâmica das passarelas investigadas, especialmente em termos de conforto humano. As respostas dinâmicas foram obtidas em termos de acelerações de pico e comparadas com valores limites propostas por diversos autores e normas de projeto. Os valores de aceleração de pico e aceleração rms encontrados na presente investigação indicaram que as passarelas analisadas apresentaram problemas relacionados com o conforto humano. Assim sendo, considerando-se que foi detectado que estas estruturas poderiam atingir níveis elevados de vibração que possam vir a comprometer o conforto dos usuários, foi verificado que uma estratégia para o controle estrutural era necessária, a fim de reduzir as vibrações excessivas nas passarelas. Finalmente, uma investigação foi realizada com base em alternativas de controle estrutural objetivando atenuar vibrações excessivas, a partir do emprego de sistemas de atenuadores dinâmicos sintonizados (ADS). / Steel and steel-concrete composite pedestrian footbridges are frequently subjected to dynamic actions with variable magnitudes due to the pedestrian crossing on the concrete deck. These dynamic actions can produce excessive vibrations and depending on their magnitude and intensity, these adverse effects can compromise the structural systems response and its reliability and may also lead to a reduction of the expected footbridge service life. The structural engineers experience and knowledge together with the use of newly developed materials and technologies have produced steel-concrete composite daring footbridges. A direct consequence of this design trend is a considerable increase of structural vibrations. Based on this scenario, this dissertation aims to investigate the dynamic behaviour of three steel-concrete composite pedestrian footbridge submitted to human walking vibration, located at Rio de Janeiro. These structural systems are composed by steel structure and a concrete slab and are destined for pedestrian crossing. Computational models were developed adopting the usual mesh refinement techniques present in finite element method simulations using ANSYS software. These numerical models have enabled a complete dynamic evaluation of the investigated footbridges especially in terms of human comfort and its associated vibration serviceability limit states. The dynamic responses were obtained in terms of peak accelerations and were compared to the limiting values proposed by authors and design standards. The peak acceleration values found in the present investigation indicated that the analysed footbridges have presented problems related to human comfort. Considering that it was detected that these structures could reach high vibration levels that might compromise the footbridge users comfort, it was proposed a structural control system in order to reduce the excessive vibrations. Thus, an investigation was performed based on some structural control alternatives for attenuating excessive vibrations using tuned mass damper (TMD) systems.
25

Análise dinâmica e controle de vibrações de pisos de edificações submetidos a atividades humanas rítmicas.

Cássio Marques Rodrigues Gaspar 05 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Um aumento crescente dos problemas estruturais associados à vibração excessiva de pisos de edificações de estruturas mistas (aço-concreto) e de concreto armado devido a atividades humanas rítmicas constitui a principal motivação para o desenvolvimento de uma metodologia de projeto respaldada na obtenção da resposta dinâmica de pisos mistos (aço-concreto) e de concreto armado, quando submetidos a cargas dinâmicas humanas rítmicas. Para tal, os modelos estruturais estudados baseiam-se em pisos de edificações mistas (aço-concreto) e de concreto armado submetidos a aulas de ginástica aeróbica. São empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Um estudo paramétrico foi realizado sobre os modelos estruturais investigados e foram obtidos valores elevados para as acelerações de pico violando os critérios de projeto e indicando níveis de vibrações excessivas. Considerando-se os aspectos mencionados anteriormente foi desenvolvida uma estratégia com base em alternativas viáveis para o controle estrutural, objetivando a atenuação das vibrações excessivas a partir da instalação de atenuadores dinâmicos sincronizados (ADS) nos pisos analisados. / The increasing incidence of building vibration problems due to human rhythmic activities led to a specific design criterion to be addressed in structural design. This was the main motivation for the development of a design methodology centred on the composite (steel-concrete) and reinforced concrete building floors dynamic response when submitted to dynamic loads due to human rhythmic activities. The structural system is composed by a composite (steel-concrete) and a reinforced concrete building floor subjected to aerobics. The proposed analysis methodology adopted the usual mesh refinement techniques present in the finite element method (FEM) simulations implemented in the ANSYS program. An extensive parametric study was developed and the results have demonstrated that the analysed composite and reinforced floor have presented high values of accelerations and excessive vibrations. Considering all aspects mentioned before, it was developed a structural control strategy aiming to reduce the floor excessive vibrations. Finally, an investigation was performed based on some structural control alternatives for attenuating excessive vibrations using Tuned Mass Damper (TMD) systems.
26

Modelagem e avaliação numérica de absorvedores dinâmicos de vibrações sintonizáveis baseados em ligas com memória de forma / Numerical modelling and assessment of tunable dynamic vibration absorbers based on shape memory alloys

Paulo Júnior, Wellington Luziano 10 December 2012 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / In the context of the so-called smart materials, shape memory alloys (SMA) have been extensively investigated aiming at various applications in different types of engineering prob- lems as well as interdisciplinary problems. Specifically, SMAs have been used for the mitiga- tion of mechanical vibrations, owing to their characteristic pseudoelastic effect, which is re- sponsible for the occurrence of hysteresis. Another relevant feature of these materials is the coexistence of two crystallographic phases (martensite and austenite), which have dissimilar mechanical properties, whose relative fractions depend on temperature and stress. In the present dissertation, this latter feature is explored in association with a strategy of passive vibration control which is based on tunable dynamic vibration absorbers (TDVA). These de- vices, once connected to a vibrating structure, can have their inertia and/or stiffness and/or damping adjusted to match the excitation frequency. Specifically, such tuning is achieved by controlling the martensite/austenite fraction by applying convenient thermal loads. By means of numerical simulations, which include the integration of the equations of motion, it is put in evidence the possibility of tuning a TDVA applied to a single degree-of-freedom system, with- in a given frequency band using two configurations of the resilient element (SMA rod and helicoidal spring). The results enable to evaluate the levels of vibration mitigation achieved and confirm that the strategy investigated can provide improved performance in terms of vibration attenuation. / No contexto dos chamados materiais inteligentes, as ligas com memória de forma (Shape Memory Alloys SMA) vêm sendo intensivamente investigadas com vistas a aplicações em diversos tipos de sistemas de engenharia e em problemas interdisciplinares. Especificamente, as SMA têm sido utilizadas para a mitigação de vibrações mecânicas, graças ao chamado efeito pseudoelástico, responsável pela ocorrência de histerese. Outra característica relevante desses materiais é a coexistência de duas fases cristalográficas (martensita e austenita), com propriedades mecânicas distintas, cujas frações relativas dependem da temperatura e da tensão. No presente trabalho, esta última característica é explorada em associação com uma estratégia de controle passivo de vibrações, baseada nos chamados absorvedores dinâmicos de vibrações sintonizáveis (ADV), que são dispositivos conectados à estrutura vibratória, cuja rigidez e/ou inércia podem ser ajustados em conformidade com a frequência de excitação, de modo que a vibração da estrutura seja altenuada. Especificamente, explora-se a possibilidade de confecção de ADVs sintonizáveis cuja rigidez pode ser ajustada por meio de variações controladas da fração relativa martensita/austenita induzidas por alterações da temperatura. Por meio de simulações numéricas, evidencia-se a possibilidade de sintonizar um ADV aplicado a um sistema vibratório de um grau de liberdade, dentro de uma dada faixa de valores de frequência, utilizando duas configurações do elemento resiliente (barra e mola helicoidal de SMA), e quantificam-se as reduções de amplitudes obtidas. Os resultados das simulações confirmam o aumento da eficiência na atenuação de vibrações proporcionado pela estratégia empregada. / Mestre em Engenharia Mecânica
27

Desempenho de TMDS em edifícios submetidos a terremotos / Performance of TMD-equipped buildings subjecto to earthquake loading

Rúbia Mara Bosse 03 March 2017 (has links)
Técnicas e dispositivos para controlar vibrações em estruturas vêm sendo desenvolvidos e aprimorados para garantir segurança a estruturas sujeitas a carregamentos dinâmicos de grande magnitude, como o caso de tufões e terremotos. Neste sentido, o controle passivo de vibrações por meio de amortecedores de massa sintonizados, TMDs (Tuned Mass Dampers), é utilizado com muita eficiência no controle de vibrações induzidas por carregamentos externos de baixas frequências, como ventos. Porém, terremotos possuem um amplo espectro de frequências e por isso não há um acordo sobre a eficácia dos TMDs ao mitigar vibrações induzidas por sismos. Neste trabalho, estudou-se a sensibilidade dos parâmetros de frequência de sintonização e razão de massa dos TMDs que influenciam seu desempenho para controlar vibrações em edifícios sob carregamentos de terremotos. Para isso utilizou-se um modelo mais preciso em elementos finitos de pórtico plano não linear geométricos para obtenção do comportamento estrutural de um edifício de 20 pavimentos. Na simulação dos terremotos, desenvolveu-se um código para geração de processos estocásticos totalmente não estacionários e espectro-compatíveis, simulados para três diferentes configurações de solo. Descobriu-se que TMDs sintonizados para altas frequências têm melhor desempenho na minimização de deslocamentos e frequências de oscilação da estrutura. Esta conclusão é contrastante com o que se encontra na literatura, de que dispositivos sintonizados para a primeira frequências natural da estrutura são mais eficientes. Também se observou que TMDs com altas razões de massa (i.e. maiores que 10%) têm melhor performance. O melhor desempenho dos TMDs foi observado em dispositivos com altas razões de massa e moderadas a altas frequências de sintonização. Este trabalho mostra que o desempenho de sistemas de controle de vibrações passivos como TMDs depende do tipo de solo, do projeto dos dispositivos, da correta avaliação da resposta estrutural e da adequada representação do fenômeno que excita a estrutura. / Techniques and devices for vibration control have been developed to ensure safety of structures subjected to relevant dinamic loads, as hurricanes and earthquakes. In this way, the passive control with TMDs (Tuned Mass Dampers) has been used with efficiency to suppress vibrations in structures subjected to low-frequency wind loads, for instance. However, for earthquakes that have a broad-banded frequency contend, there is no general agreement about the performance of TMDs. In this thesis, the sensitivity of TMD parameters that influence the performance of the devices is evaluated. An accutare non-linear plane frame finite element (FE) formulation is employed to estimate the structural behaviour of a 20-storey building under earthquake loads. For the representation of earthquakes, a code was developed for the generation of fully non-stationary spectrum-compatible stochastic process, for three types of soil. It was found that TMDs tuned to higher frequencies perform better at minimizing displacements and vibration frequencies, in contrast to what is commonly believed (e.g., that devices tuned to the building\'s fundamental natural frequency present ideal performance). Further, a compounding effect is also observed, with the best performance being obtained by TMDs of large mass tuned to moderate to high frequencies. The thesis shows that the performance of passive systems like TMDs depend on the type os soil, the design of the absorbers, the correct evaluation of structural behaviour and the right representation of the phenomenon that excitates the structure.
28

Controle ativo-passivo de vibrações estruturais usando materiais piezelétricos: otimização e quanticação de incertezas / Acitve-passive strucutural control using piezoelectric materials: optimization and uncertainty quantification

Heinsten Frederich Leal dos Santos 14 November 2012 (has links)
Esta tese apresenta uma análise numérica do controle de vibrações estruturais através de cerâmicas piezelétricas em extensão conectadas a circuitos ativo-passivos compostos por resistência, indutância e fonte de tensão. Para tal, um modelo de elementos finitos de vigas sanduíche com três camadas elásticas e/ou piezelétricas foi desenvolvido. Realizou-se também uma modelagem dos componentes do circuito elétrico e seu acoplamento à estrutura gerando assim uma equação de movimento acoplada para a estrutura com elementos piezelétricos conectados aos circuitos elétricos. Uma análise harmônica das equações obtidas foi realizada para se obter uma avaliação preliminar dos efeitos causados pelos componentes elétricos do circuito na estrutura. Observou-se que os elementos passivos do circuito, resistência e indutância, tem não somente um efeito de absorvedor dinâmico de vibrações mas, também, promovem uma amplificação da autoridade de controle no caso de se atuar através da fonte de tensão. Usando a metodologia tradicional de projeto de absorvedores dinâmicos de vibrações, derivou-se expressões para os valores de resistência e indutância de modo a maximizar o desempenho passivo do sistema. Uma análise do efeito de incertezas das constantes piezelétricas e dielétricas da cerâmica piezelétrica considerada e dos componentes de resistência e indutância do circuito elétrico no desempenho do controle passivo e ativo-passivo de estrutura tipo viga cantilever foi realizada. O objetivo desta análise foi quantificar robustez e sensibilidade do controle proposto. Em sequida, um estudo de otimização dos valores de resistência e indutância do circuito elétrico em função da tensão elétrica de controle máxima a ser aplicada em uma placa com diversos atuadores piezelétricos foi realizado. Finalmente e também para a estrutura tipo placa, uma análise de incertezas da rigidez da cola na interface entre estrutura e atuadores piezelétricos e seus efeitos no desempenho do controle passivo e ativo-passivo foi realizada. / This work presents a numerical analysis of the structural vibration control using piezoelectric materials in extension mode connected to active-passive electric circuits composed of resistance, inductance and voltage source. For that, a finite element model for sandwich beams with three elastic or piezoelectric layers was developed. A modeling of the electric circuit dynamics and its coupling to the structure with piezoelectric elements was also done. A harmonic analysis of the resulting equations was performed to yield a preliminary evaluation of the effects caused by the electric circuit components on the structure. It was observed that the passive circuit components not only lead to a dynamic vibration absorber effect but also to an amplification of the control authority in case of actuation using the voltage source. Using the standard methodology for the design of dynamic vibration absorbers, expressions were derived for the resistance and inductance values that optimize the passive vibration control performance of the system. An analysis of the effect of uncertainties of piezoelectric and dielectric constants of piezoelectric ceramic and resistance and inductance components of the shunt circuit on the passive and active-passive control performance for a cantilever beam structure was performed. The objective of this analysis was to quantify robustness and sensitivity of the proposed control. Then, an optimization study of the values of resistance and inductance of the shunt circuit as a function of the maximum control voltage to be applied on a plate with several piezoelectric actuators was performed. Finally and also for the plate structure, an analysis of uncertainties in the stiffness of the adhesive interface between structure and piezoelectric actuators and their effects on the performance of passive control and active-passive was performed.
29

Análise de desempenho de diferentes leis de controle de vibrações torcionais em colunas de perfuração de poços de petróleo / Performance analysis of different control laws for torsional vibrations in oil wells drillstrings

Hugo Leonardo Salomão Monteiro 09 April 2012 (has links)
O fenômeno de stick-slip, no processo de perfuração de poços de petróleo, é propiciado pela interação entre broca e formação rochosa e pode dar origem a grandes oscilações na velocidade angular podendo provocar danos irreparáveis ao processo. Neste trabalho, analisa-se o desempenho de leis de controle aplicadas à mesa rotativa (responsável por movimentar a coluna de perfuração), visando à redução de stick-slip e de oscilações da velocidade angular da broca. As leis de controle implementadas são do tipo PI (Proporcional-Integral), com parcelas de torque aplicado à mesa rotativa, proporcional e integral à velocidade da mesa, podendo ser com peso na broca constante ou variável. Para a coluna de perfuração, foi proposto um modelo em elementos finitos com função de forma linear. O torque na broca foi modelado segundo atrito de Coulomb pela forma não regularizada, curva esta ajustada pelos dados empíricos conforme propostas da literatura. Diversos critérios de desempenho foram analisados e foi observado que a minimização do desvio médio da velocidade angular em relação à referência propicia melhores condições de operação. Análises paramétricas dos ganhos de controle proporcional e integral foram realizadas, dando origem a curvas de nível para o desvio médio de velocidade angular na broca. A partir destas curvas, foram definidas regiões de estabilidade nas quais o desvio é aceitável. Estas regiões foram observadas serem maiores para menores pesos na broca e maiores velocidades angulares de referência e vice-versa. A adição do controle do peso na broca permitiu uma redução global dos níveis de desvio médio de velocidade angular, dando origem a um aumento das regiões de estabilidade do processo de perfuração. / The stick-slip phenomenon, in the process of drilling oil wells, due to the interaction between drill and rock formation can lead to large fluctuations in drill-bit angular velocity and, thus, cause irreparable damage to the process. In this work, the performance of control laws applied to the rotary table (responsible for moving the drill string) is analyzed, in order to reduce stick-slip and drill-bit angular velocity oscillations. The control laws implemented are based on a PI (Proportional-Integral) controller, for which the torque applied to the rotating table has components proportional and integral to table angular velocity with constant or variable WOB (Weight On Bit). For the drillstring, a finite element model with a linear interpolation was proposed. The torque on the drill-bit was modeled by a non-regularized Coulomb friction model, with parameters that were adjusted using empirical data proposed in literature. Several performance criteria were analyzed and it was observed that the minimization of the mean deviation of the drill-bit angular velocity relative to the target one would provide the best operating condition. Parametric analyses of proportional and integral control gains were performed, yielding level curves for the mean deviation of drill-bit angular velocity. From these curves, stability regions were defined in which the deviation is acceptable. These regions were observed to be wider for smaller values of WOB and higher values of target angular velocity and vice-versa. The inclusion of a controlled dynamic WOB reduced the levels of mean deviation of angular velocity, leading to improved stability regions for the drilling process.
30

Less conservative conditions for the robust and Gain-Scheduled LQR-state derivative controllers design /

Beteto, Marco Antonio Leite January 2019 (has links)
Orientador: Edvaldo Assunção / Resumo: Neste trabalho é proposta a resolução do problema do regulador linear quadrático (Linear Quadratic Regulator - LQR) via desigualdades matriciais lineares (Linear Matrix Inequalities - LMIs) para sistemas lineares e invariantes no tempo sujeitos a incertezas politópicas, bem como para sistemas lineares sujeitos a parâmetros variantes no tempo (Linear Parameter Varying - LPV). O projeto dos controladores é baseado na realimentação derivativa. A escolha da realimentação derivativa se dá devido à sua fácil implementação em certas aplicações como, por exemplo, no controle de vibrações. Os sinais usados na realimentação são aceleração e velocidade, sendo obtidos por meio de acelerômetros. Por meio do método proposto é possível obter condições LMIs para a síntese de controladores que garantam a estabilização do sistema em malha fechada, sendo que os controladores possuem desempenho otimizado. Para a formulação das condições LMIs, uma função de Lyapunov do tipo quadrática é utilizada. Exemplos teóricos e simulações são utilizados como forma de validação dos métodos propostos, além de mostrar que os novos resultados apresentam condições menos conservadoras. Além disso, ao final é apresentada uma implementação prática em um sistema de suspensão ativa, produzida pela Quanser®. / Abstract: The resolution of linear quadratic regulator (LQR) problem via linear matrix inequalities (LMIs) for linear time-invariant systems subject to polytopic uncertainties, as linear systems subjects to linear parameter varying (LPV), is proposed in this work. The controllers' designs are based on the state derivative feedback. The aim to the choice of the state derivative feedback is your easy implementation in a class of mechanical systems, such as in vibration control, for example. The signals used for feedback are acceleration and velocity, it is obtained by means of accelerometers. Through the proposed method it is possible to obtain LMIs conditions for the synthesis of controllers that guarantee the stabilisation of the closed-loop system, being that the controllers have optimised performance. For the LMIs conditions formulations, a Lyapunov function of type quadratic is used. As a form of validation, theoretical examples and simulations are performed, besides to show that the new results are less conservative. Furthermore, a practical implementation in an active suspension system, produced by Quanser®, is performed. / Mestre